Guide to Low Resistance Testing

Technical DataMjolner200Mjolner600MOM2MOM200MOM600AMOM690CommentsTest currents5 - 200 A5 - 600 A220 A0 - 200 A0 - 600 A0 -800 ACurrent steps1 A1 AMax test time at max current2 min15 sec3 sec - discharging20 sec15 secInstant shut offMax continuous current200 A300 AN/A100 A (15 min)100 A100 A (10 min)Long test times can help locate weaknesses by heatingMax. resistance for max. current19mΩ, with cables2mΩ, with cables2 mΩ, with cables17mΩ, with cables9mΩ, with cablesWith cables, 600A 0,5mΩSubtract expected test resistance and you can calculate max. test lead length ***Power limited to 0.25W for sensitive applicationsMeasurement range0 μΩ - 999.9 mΩ0 μΩ - 999.9 mΩ0 μΩ - 1000 mΩ0 μΩ - 19.99 mΩ0 μΩ - 1999 mΩ0 μΩ - 200 mΩBest resolution0.1 μΩ0.1 μΩ1.0 μΩ1.0 μΩ1.0 μΩ1.0 μΩInaccuracy± 0.3 μΩ± 0.3 μΩ± 1% + 1μΩ± 1% + 1 μΩ± 1% + 1 μΩ± 1% + 1 μΩRipple free DC■■■Ideal for testing circuit breakers with active relay system connected without trippingAdditional smoothing on DCCan test most circuit breakers with active relay system connected without trippingDualGround■■■Used when testing circuit breakers with both side connected to ground, with out additional inaccuracy.Ramp up/down (Automatic)■■Ideal for testing circuit breakers with active relay system connected without trippingAC Demagnetization■Remote control■■■Built in printer■■User settable High and low test limits■Ideal for rapid testing to pre-determined test limitsData storage■■■Memo field for stored test resultsMake note of issues or corrective action requiredCommunication PCUSBUSBBluetooth■Battery operated■*Operates from line supply even with a dead batteryCAT rating *CAT I**Touch proof clips reduce chance of causing arc flash over in live environmentsExternal voltage protectionParticulary important when testing in close vicinity of live voltageNoise immunity specReflects instruments ability to work in electrically noise environments such as high voltage sub-stationsIP ratingIP41IP41IP54IP20IP20IP20High IP ratings ideal for outdoor operation Tough transport case housing■■Weight excluding leads8.8 kg (20 lbs)13.8 kg (31 lbs)1.0 kg (2lbs)14.6 kg (32 lbs)24.7 kg (55 lbs)23.7 kg (52 lbs)Weight excluding leadsDimensions486 x 392 x 192 mm(19 x 15 x 7.6 in)486 x 392 x 192 mm(19 x 15 x 7.6 in)217 x 92 x 72 mm(8.5 x 3.6 x 2.8 in)280 x 178 x 246 mm(11 x 7 x 9.7 in)356 x 203 x 241 mm(14 x 8 x 9.5 in)350 x 270 x 220 mm(14 x 11 x 8.7 in)Dimensions *For measuring circuits used to measure any other electrical signal (CAT II the transient stresses must be considered by the user to assure that they do not exceed the capabilities of the measuring equipment. The expected transient level for CAT IV is 6000 V, CAT III 4000 V, CAT II 2500 V and for CAT I 1500 V. For CAT I the transient levels can be specified differently and they are then designed and tested accordingly to assure that they withstand the expected transients.www.megger.com 4342 A guide to low resistance testing www.megger.com

Previous page: Guide to Low Resistance Testing [22 / 25]

Next page: Guide to Low Resistance Testing [24 / 25]