— Motor protection and control—MAIN CATALOG 2019 Motor protection and controlManual motor starters, contactors and overload relays
150102030405060708091011121314—Motor protection and controlManual motor starters,contactors and overload relaysOVERVIEWAS CONTACTORS AND NS CONTACTOR RELAYSMANUAL MOTOR STARTERS AND TRANSFORMER PROTECTIONOVERLOAD RELAYSAF, EK CONTACTORS AND NF CONTACTOR RELAYSTHERMISTOR PROTECTION REL AYSDRAS AND DRAF ENCLOSED STARTERSB MINI CONTACTORS, K MINI CONTACTOR RELAYSSELF RESETTING CURRENT LIMITING MODULEELECTRONIC COMPACT STARTERSUNIVERSAL MOTOR CONTROLLERCUSTOMER MADE MOTOR STARTING SOLUTIONCERTIFICATIONS AND APPROVALS - GENERAL TECH N IC A L DATAINDEXMARKETING MATERIAL
1/2ABB MOTOR PROTECTION AND CONTROL•Thermal and electronic type•Up to 200 A (thermal) and 1250 A(electronic)•Direct mounting to AF contactors•Fuseless motor and transformer protection up to 80 A•Designed to perfectly combine with ABB contactors•Harmonized accessory range •3-pole and 4-pole AC / DC electronic control coil from 9 up to 2850 A AC-1, 500 kW AC-3• GAF contactors for solar application•UA...UA..RA for capacitor switching•AFS contactors for safety applications—03—02—Protection and controlTo keep things running you need controlManual motor starters and transformer protectionContactors and contactor relays•Up to 20 A AC-1 / 5.5 kW AC-3 400 V•Flattest mini contactors on the market• 3 different connecting terminals available•Wide accessories assortmentMini contactors and mini contactor relays—04• Compact and powerful - up to 7.5 kW AC-3•Designed for OEM's•Specially suitable for motor controlapplicationContactors and contactor relays designed for OEM's—05—06Overload relays01
sommaire illustre_produit - Rev. BABB MOTOR PROTECTION AND CONTROL 1/3•Monitoring of the winding temperature of motors which have PTC temperature sensors installed•Evaluation of various motor conditions such as overheating, overload and in-sufficient cooling•ATEX approval available for the use in hazardous areas•Increases the short-circuit breaking capacity of downstream devices•Ideal solution for group protection•For machine or wall mounting motor starter•Up to 7.5 kW•Robust IP66 and type 4X enclosure•Forward and reverse running, motor protection, emergency stop•Space saving up to 90% with only 22.5mm width•Up to 75% reduced time in wiring and installation: less error-prone wiring• Provision of detailed operational, diag-nostic and service data continuously• Effective data source for modern predic-tive maintenance systems in any plant• Seamless integration into ABB Ability™ System 800xA platform•Coordination type 1 and 2 for - Direct-on-line starting - Reversing starters - Start-delta starters•Full range of connecting kits—07—08—09Thermistor protection relaysSelf resetting current limiting moduleEnclosed starters—10—11—12Electronic compact startersUniversal motor controllerCustomer made motor starting solution guide01
1/4ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—Protection and controlTo keep things running you need controlABB's protection and control solutions set the standard in sustainable performance, reliability and shapes your daily life. ABB certified products and processes make it easier to design and service equipment through easy engineering, optimized logistics, simple installations, energy savings, reduced maintenance and long lasting solutions.—01 Appliances—02 Elevator—03 Food & beverage—01 —02 —03 01
ABB MOTOR PROTECTION AND CONTROL 1/51SBC100214C0201_page comFrom small controls to power distributionFor system integrators, OEMs, engineering consultants and distributors to panel builders and industrial end-users, ABB’s comprehensive range of motor starting solutions, products and services delivers the certainty of consistent quality and performance.Control matters, productivity and safety relies on keeping things running. ABBs control and protection solutions ensure performance when it is needed the most.—05 —04 —06—04 EV charging—04 WInd power—06 Solar power01
1/6ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—Manual motor starters A complete motor protection conceptUp to 80 AWell coordinated and IE3 ready starter combinationsABB provides coordination tables for the selection of low voltage equipment specifically designed for starting and protecting IE2 and IE3 motors. ABB ́s SOC tool (Selected Optimized Coordination) is available at:https://applications.it.abb.com/SOC/Page/Selection.aspxCombines naturally with ABB contactor rangesABB manual motor starters match perfectly and are easy to connect with ABB motor control devices, to create type 1 or type 2 motor staring solutionsProtect equipment and installations with manual motor startersManual motor starters, are mainly used to switch motors ON/OFF manually and to provide fuseless protection against short-circuit, overload and phase failures. ABB manual motor starters save costs, space and ensure a quick reaction under short-circuit condition by switching the motor off within milliseconds. 01
ABB MOTOR PROTECTION AND CONTROL 1/71SBC100214C0201_page com—AF contactors One range for motor starting and power switching Up to 2850 A AC-1Complete global rangeAF contactor range features a full assortment of accessories, thermal or electronic overload relays, connecting accessories, is available as standard globally and meets all major international and na-tional standards, and marine applicationsFeaturing AF technology as standardABB range of AF contactors is the industry benchmark. The integrated electronically controlled coil offers multiple benefits over conventional alternatives, and together with ABB's wide product offering an optimal configuration, every time.3-pole and 4-pole rangeAF is available as 3-pole contactors from 9A up to 1060 A AC-3 or up to 2850 A AC-1 and as 4-pole contactors up to 525 A AC-1 all with AC / DC wide operational voltage range coils.01
1/8ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—Just push-it The next generation of spring technologyUp to 38 AReliable as ever connections for manual motor starters and for contactors With the new Push-in Spring motor starting solution, one push is all you need for extremely fast wiring. No tool is required, so you can save up to 50% wiring time with Push-in Spring compared to conventional spring solutions, and the connections are just as reliable. So for speed, ease and reliability, just push it.Push-in mode or spring mode in the same terminalFor the very first time on the market, ABB's 2-in-1 connection allows you to use ferruled and rigid cables (Push-in mode) or cables without ferrules (Spring mode) in the same terminal. In Push-in mode, cables can be inserted by just simply push-ing them in by hand.Faster than ever installation, Easier than ever wiring01
ABB MOTOR PROTECTION AND CONTROL 1/91SBC100214C0201_page com—AFS contactors Because safety mattersUp to 96 AContactors dedicated for safety applicationEasy to identify with its yellow signature, while enjoying the latest AF technology on board, AFS contactor is the chain link specially dedicated for safety application systems.Designed for machine safety applications,AFS contactors come with fixed front auxiliary contact blocks, making them ideal for monitoring and controlling circuits.Safety down to the detailContactors status is guaranteed with mechanically linked and mirror contacts .Non removable safety cap prevent unexpected manual operation.Mechanically linked and mirror contacts Factory-mounted, non-removable, safety cap01
1/10ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—B mini contactorsEfficient and space savingUp to 5.5 kW AC-3The flattest mini contactor on the marketB mini contactors are ideally suited for applications where reliability is a must and space is at a premium. The dimensions, technical features and the variety of the assortment provide customers a high flexibility in a wide-range of applications.Small in all variantsB mini contactors or mini interface relays have screw, flat pin or soldering pin terminals; noise free AC or DC operated coil always within the same small dimensions and its compact reversing starter has no spacing required for its built-in mechanical interlock. Its screw or din rail mount also helps make it simple to engineer compact panels.Hides in any placeB mini contactors can be used in any place such as for house or hotel fittings, small house equipment, swimming pools, your workshop or garage door as well as for bakeries or any machine that requires a very small control device. Mini contactors has its marine approvals like any other ABB big brother.01
ABB MOTOR PROTECTION AND CONTROL 1/111SBC100214C0201_page com—AS contactorsCompact and powerfulUp to 16 A AC-3Designed for OEMsAS solution has been specially designed for OEM applications. It allows to assemble starting solutions in compact size either with AC coil or DC coil and with screw terminals or spring terminals.ACDCorW 45 x H 68 x D 72.5 mm All in same dimensionsAS contactors feature AC and DC control circuits, screw or spring terminals all in 45 mm width modules with no spacing required even when they are combined with motor protection devices for direct-on-line reversing or star delta starters.Spring Spring terminalScrew Screw terminalMainly for motor controlCombined with motor protection devices, AS 3-pole contactors are specially suitable for motor control applications such as ventilation systems, air condi-tioning, small pumps, escalators, laundries or food and baking equipment01
1/12ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—GF and GAF contactorsA compact and efficient way to switch DC loadsOptimal for central invertersABB offers the widest range of compact contactors for DC load switching in low voltage power distribution. Thanks to their breaking performance of DC circuits, GF contactors will switch DC-PV3 inverter loads up to 1325 A 1500 V DC and GAF contactors will switch DC loads up to 2050 A 1000 V DC-1.— PV solar plantcontactortype AFcontactortype GAFPV stringsSolar PVcentral inverterACGrid sideDC01
ABB MOTOR PROTECTION AND CONTROL 1/131SBC100214C0201_page com—UA and UA..RA contactorsFor capacitor switching up to 80 kvarSafely switch your capacitor banks without contacts weldingABB offers the widest contactor range on the market for the capacitor switching demanding application. UA..RA contactors with damping resistors, are used when inrush peak currents are far exceeding 100 times. UA contactors is a simple solution used when peak currents are less or equal to 100 times nominal rms current.Power factor correctionIndustrial sites have low power efficiency due to motor winding inductances. Capacitor bank panels are added for power factor correction.An automatic power factor correction system consists of several capacitor banks of identical or different ratings (sev-eral steps), energized separately according to the value of the power factor to be corrected.The inrush current peak, in the case of automatic correction, depends on the power of the steps already on duty, and can reach 100 times the nominal current of the step to be ener-gized.Switching capacitors banks with standard contactors may cause electrical damages like contact welding, coil burning or even fire on the installation.ABB provides a choice of contactors dedicated for capacitor switching applications and CAPCAL a selection tool, avail-able on the ABB Website: https://new.abb.com/low-voltage/products/motor-protec-tion/contactors-for-capacitor-switchingLoadsTe m p.ProbeFan(s)OutputsCurrentTransformerMain Circuit BreakerControlTransformerAutomatic capacitors bank with reactorsPower TransformerRVTP. F.CC1C2C3C11C12BkCapacitor#1 Capacitor#2 Capacitor#3 Capacitor#11 Capacitor#12 R1R2R3R11R12FU-1FU-2FU-3FU-11FU-1201
1/14ABB MOTOR PROTECTION AND CONTROL1SBC100214C0201_page com—HF rangeGreat functionality in only 22.5 mmElectronic compact startersDirect-on-line, reverse start, overload protection and emergency stop is all integrated in one compact device of only 22.5 mm width. Reliable 30 millions switching cycles for motors up to 3 kW / 400 V AC, reduced wiring time and faults are additional benefits.Short circuit protectionCoordinated short circuit protection for single and group mounting with manual motor starters is available. Safety and ATEXIn combination with Sentry safety relays the HF-Starter reaches SIL3, PL e certification. Feel free to use safety tools like FSDT and Sistema. The libaries are online on ABB.com. Additionally safety variants are ATEX certified.22.5 mmSpace-savingCompared to conven-tional solution space saving is optimized. +Control of cooling tanksThe HF range is used to con-trol pumps and compressor for cooling.Solar trackerThe panels follow the sun and need to be switched frequently in a small cabinet.Snow canonsSimiliar to the solar tracker the snow canon is switched left and right to ensure equal snow conditions.Straightening metalThe metal is unrolled directly from the coil. The motor needs to be switched frequenty. 01
ABB MOTOR PROTECTION AND CONTROL 1/151SBC100214C0201_page com—Contactors and motor protection for rolling stockSustainable mobility for a better worldSpecifically designed and manufactured for rolling stock applications (1), our products can be installed in any environment including passenger or driver cabins, for main or urban line trains, underground trains or trams circulating frequently in tunnels or underground passages.With the latest technology in our product for rolling stock you can•Simplify your installation thanks to compact solution andmodular frame size•Reduce train energy consumption with lighter devices increasing passenger capacity and less coil energy consumption improving power management.•Optimize your logistics and stocks•Protect persons and equipment with products specificallydesigned to meet the latest rolling stock requirements•Secure uptime thanks to AF technology, handle the largevoltage fluctuation to battery use•Reduce maintenance costs, downtimes and make trouble-shooting easier with real motor protection.Ventilation, air coditioningExterior / interiordoor and stepFlapsLightingBrakeVehicleHeatingPropulsionGear controlHygiene cubiclesControl convertersUnderfloor containers(1) Important notice:Standard contactors are not suitable for rolling stock applications due to the spe-cific requirements in terms of norms, performance and approvals.For rolling stock applications, please contact your local ABB sales representative.01
1/16ABB MOTOR PROTECTION AND CONTROL—How to use this catalogABB MOTOR PROTECTION AND CONTROL 3/171SFC101088C0201 - Rev. D1SFC101005V0001AF146-30-001SFC101006V0001AF146-30-00B—AF116 ... AF146 3-pole contactors55 to 75 kWAC / DC operatedAF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC -can manage large control voltage variations - r educed panel energy consumption -very distinct closing and opening -can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps551607516024...6020...6000AF116-30-00-111SFL427001R11001.75048...130 48...13000AF116-30-00-121SFL427001R12001.750100...250 100...25000AF116-30-00-13 1SFL427001R13001.750250...500 250...50000AF116-30-00-141SFL427001R14001.7507520010020024...6020...6000AF140-30-00-111SFL447001R11001.75048...130 48...13000AF140-30-00-121SFL447001R12001.750100...250 100...25000AF140-30-00-131SFL447001R13001.750250...500 250...50000AF140-30-00-141SFL447001R14001.7507522510020024...6020...6000AF146-30-00-111SFL467001R11001.75048...130 48...13000AF146-30-00-121SFL467001R12001.750100...250 100...25000AF146-30-00-13 1SFL467001R13001.750250...500 250...50000AF146-30-00-141SFL467001R14001.750With bar connections551607516024...6020...6000AF116-30-00B-111SFL427002R11001.50048...130 48...13000AF116-30-00B-121SFL427002R12001.500100...250 100...25000AF116-30-00B-13 1SFL427002R13001.500250...500 250...50000AF116-30-00B-141SFL427002R14001.5007520010020024...6020...6000AF140-30-00B-111SFL447002R11001.50048...130 48...13000AF140-30-00B-121SFL447002R12001.500100...250 100...25000AF140-30-00B-13 1SFL447002R13001.500250...500 250...50000AF140-30-00B-141SFL447002R14001.5007522510020024...6020...6000AF146-30-00B-111SFL467002R11001.50048...130 48...13000AF146-30-00B-121SFL467002R12001.500100...250 100...25000AF146-30-00B-13 1SFL467002R13001.500250...500 250...50000AF146-30-00B-141SFL467002R14001.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.SECTION E-E 55.5 0.22"150 5.91"90 3.54"19.5 4.96"126 4.96"30 1.18"DDEESECTION E-E 55.5 2.18"19.5 0.77"126 4.96"90 3.54"150 5.91"30 1.18"DDAF116, AF140, AF146-30-00AF116, AF140, AF146-30-00BMain dimensions mm, inches03Draft, ne pas diffuser Fri Oct 26 2018 11:31:09 GMT+0200 (Romance Standard Time)Product order codeclick on the product order code to obtain the data sheet, the agreement and all technical information regarding that reference. Product order codeFor direct product details information, use product type or order code, ex:www.abb.com/product-details/AF09-30-10-13 or www.abb.com/product-details/1SBL137001R1310Product imageClick on the product to zoom in.Product typeClick on the product type to get 2D and/or 3D drawings.—Find more information on our marketing material page.Web catalogPrint catalogChart and datas of motor rated operational powers and currents are available in the customer made motor starting solutions chapter.The products in this catalogue can also be found together with product news life cycle status, data sheets, certificates and tools at: https://new.abb.com/low-voltage/products/ motor-protection01
1SBC100214C0201_Glossary - Rev. BABB MOTOR PROTECTION AND CONTROL 1/17Ordering detailsOrders can be placed either using the type code or the order code. The type codes or ordering codes generally relate to single devices like a contactor, overload relays or an acces-sory but they can sometimes relate to an indivisible set (ex: connecting kits) or a bag (ex 50 function markers). See the description of the device.Packaging unitProducts are generally packed as single units but very small products or accessories are often proposed in collective packs. Please refer to the “Package quantity” in the ordering detail charts.Standards and approvals for the productsProducts in this catalogue are designed tested and have third party approvals and markings in compliance with ma-jor international or local standards such as EN/IEC 60947-1, EN /IEC947-4-1, EN/IEC 60947-2, EN/IEC 60947-5-1 or UL 60947-4-1. See approvals and certification section.Standards and approvals for design and manufacturingABB has set up a quality assurance organization in compli-ance with the requirements of ISO 9001 standard and ABB factories are ISO 9001 approved.GuaranteeThe information contained in this catalogue reflects the current state of our knowledge and aims to present our products and their possible applications as defined with the standards. The product data, ratings and utilization conditions are indicated in their respective sections, thus the information does not guarantee special utilizations or combination of characteristics that have not been defined or tested according to normalized values or test conditions defined with the standards.LiabilityThe devices in this catalogue do not endanger safety when they are selected, mounted, commissioned used maintained and deposed with the rules and standards that apply to them.Railways applications for rolling stock are not covered with this catalogueThe products in this catalog do generally not meet the spe-cial requirements and approvals for rolling stock applica-tions. ABB offers specifically approved products processes and support for this application.For rolling stock application see our dedicated portalhttps://new.abb.com/low-voltage/products/motor-protection/contactors-and-motor- protection-for-railway-applications01
1SBC100214C0201_tools1/18ABB MOTOR PROTECTION AND CONTROLSelected Optimized Coordination tables SOCCadenas portal: Download 2D or 3D files according to your needs (STEP, IGES...)For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 or www.abb.com/productdetails/1SBL137001R1310https://econfigure.xe.abb.com/global/#/categories/cfg-solution-Configurators—Main online tools2D and 3D CAD models, ABB CAD Download centerSelected Optimized Coordination tables - SOCData sheets instructions, manuals and certificatesConfigurators e-Configure01
1/19ABB MOTOR PROTECTION AND CONTROL—ABB ConnectYour digital assistantConnect to your electrification solutions with your digital assistant, access the latest news and create your own digital workspace; search 'ABB Connect' on the Apple App Store, Google Play Store or Microsoft Store and download today. new.abb.com/low-voltage/service/abb-connect Find the latest product detailsMake your phone or tablet your workspaceTap and stay connected to all the latest informationScan and download ABB Connect for IOS, Android or Windows 10
1/20ABB MOTOR PROTECTION AND CONTROLIEC (1)AC-3 Rated operational powerθ ≤ 60 °C (2), 400 VkW45.545.57.545.57.5111518.518.52230374555757590110132160200200250315400—475560———UL/CSA3-phase motor rating480 Vhp3557.51057.51015202530405060 6075100 100125150200250300350400500600—800900———AC / DC Control supplyTy pe—————AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850AC Control supplyTy peB6B7AS09AS12AS16AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850DC Control supplyTy peBC6BC7ASL09ASL12ASL16AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850IECAC-3 Rated operational currentθ ≤ 60 °C (2), 400 V A8.511.591215.5912182632384053658096116140 146190205265305370400460580750—8601060———AC-1 Rated operational currentθ ≤ 40 °C, 690 V A20 (400 V)20 (400 V)22242425283045505070100 1051251301602002252753504005006006007008001050126013501650205026502850UL/CSAGeneral use rating600 V A12 (300 V)16202020252830455050608090105115160200 200250300350400520550650750900121013501650210027002850NEMANEMA Size——00000000—1——2——3——4———5———6—7——8———(1) 1000 V IEC ratings available for AF80, AF96 and AF146 ... AF2650 contactors.(2) θ ≤ 55 °C for mini contactors and AF400 ... AF2650 contactors.Main accessoriesAuxiliary contact blocksFront mountingCAF6CA3-10 (1 x N.O.) CA3-01 (1 x N.C.)CA4-10 (1 x N.O.) CA4-01 (1 x N.C.)Side mountingCA6CAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11(1 x N.O. + 1 x N.C.)CAL18-11 (1 x N.O. + 1 x N.C.)TimersElectronicTEF3-ONTEF3-OFFTEF4-ONTEF4-OFFInterlocking units (3)MechanicalVM3VM4VM96-4VM19(for same size contactors)VM750HVM750VVM1650HMechanical / ElectricalVEM4Connection setsFor reversing contactorsBSM6-30BER16C-3BER16-4BER38-4BER65-4BER96-4BER140-4BER205-4BER370-4BEM460-30BEM750-30Surge suppressorsVaristor (AC/DC)RV-BC6RV5 (24...440 V)Built-in surge protectionRC type (AC)RC5-1 (24...440 V)Transil diode (DC)RD7RT5 (12...264 V)(3) See available reversing contactors VB6, VB7 and VAS09 ... VAS16.Overload relaysThermal relaysClass 10(Class 10A for TF140, TA200DU)T16 (0.10...16 A)T16 (0.10...16 A)TF42 (0.10...38 A)TF65 (22...67 A)TF96 (40...96 A)TF140DU(66...142 A)θ ≤ 55 °CTA200DU(66...200 A)θ ≤ 55 °CElectronic relaysClass 10E, 20E, 30EE16DU (0.10...18.9 A)EF19 (0.10...18.9 A)EF19 (0.10...18.9 A)EF45 (9...45 A)EF65 (20...70 A)EF96 (20...100 A)EF146 (54...150 A)EF205 (63...210 A)EF370 (115...380 A)EF460 (150...500 A)EF750(250...800 A)EF1250DU(350...1250 A)Manual motor startersThermal / magnetic protectionClass 10MS116 (0.10...32 A) Ics up to 50 kA for class 10AMS116 (0.10...32 A)lcs up to 50 kA for class 10AMS165 (10...80 A)lcs up to 100 kAMS132 (0.10...32 A) Ics up to 100 kAMS132 (0.10...32 A)lcs up to 100 kAMagnetic only typesMO132 (0.16...32A)MO132 (0.16...32 A)Ics up to 100 kAMO165 (16...80 A)lcs up to 100 kAAccessoriesFor contactor mountingBEA7/132BEA16-3BEA16-4BEA38-4BEA65-4 (4)(4) BEA65-4 suitable for MS165 and MO165 only.Contactors 3-pole contactorsMini contactors—General overview motor protection and control01
ABB MOTOR PROTECTION AND CONTROL 1/21IEC (1)AC-3 Rated operational powerθ ≤ 60 °C (2), 400 VkW45.545.57.545.57.5111518.518.52230374555757590110132160200200250315400—475560———UL/CSA3-phase motor rating480 Vhp3557.51057.51015202530405060 6075100 100125150200250300350400500600—800900———AC / DC Control supplyTy pe—————AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850AC Control supplyTy peB6B7AS09AS12AS16AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850DC Control supplyTy peBC6BC7ASL09ASL12ASL16AF09AF12AF16AF26AF30 AF38AF40AF52AF65AF80AF96AF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850IECAC-3 Rated operational currentθ ≤ 60 °C (2), 400 V A8.511.591215.5912182632384053658096116140 146190205265305370400460580750—8601060———AC-1 Rated operational currentθ ≤ 40 °C, 690 V A20 (400 V)20 (400 V)22242425283045505070100 1051251301602002252753504005006006007008001050126013501650205026502850UL/CSAGeneral use rating600 V A12 (300 V)16202020252830455050608090105115160200 200250300350400520550650750900121013501650210027002850NEMANEMA Size——00000000—1——2——3——4———5———6—7——8———(1) 1000 V IEC ratings available for AF80, AF96 and AF146 ... AF2650 contactors.(2) θ ≤ 55 °C for mini contactors and AF400 ... AF2650 contactors.Main accessoriesAuxiliary contact blocksFront mountingCAF6CA3-10 (1 x N.O.)CA3-01(1 x N.C.)CA4-10 (1 x N.O.)CA4-01 (1 x N.C.)Side mountingCA6CAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11 (1 x N.O. + 1 x N.C.)CAL18-11 (1 x N.O. + 1 x N.C.)TimersElectronicTEF3-ONTEF3-OFFTEF4-ONTEF4-OFFInterlocking units (3)MechanicalVM3VM4VM96-4VM19 (for same size contactors)VM750HVM750VVM1650HMechanical / ElectricalVEM4Connection setsFor reversing contactorsBSM6-30BER16C-3BER16-4BER38-4BER65-4BER96-4BER140-4BER205-4BER370-4BEM460-30BEM750-30Surge suppressorsVaristor (AC/DC)RV-BC6RV5 (24...440 V)Built-in surge protectionRC type (AC)RC5-1 (24...440 V)Transil diode (DC)RD7RT5 (12...264 V)(3) See available reversing contactors VB6, VB7 and VAS09 ... VAS16.Overload relaysThermal relaysClass 10(Class 10A for TF140, TA200DU)T16(0.10...16 A)T16(0.10...16 A)TF42 (0.10...38 A)TF65 (22...67 A)TF96 (40...96 A)TF140DU (66...142 A)θ ≤ 55 °CTA200DU (66...200 A)θ ≤ 55 °CElectronic relaysClass 10E, 20E, 30EE16DU (0.10...18.9 A)EF19 (0.10...18.9 A)EF19(0.10...18.9 A)EF45 (9...45 A)EF65 (20...70 A)EF96 (20...100 A)EF146 (54...150 A)EF205 (63...210 A)EF370 (115...380 A)EF460 (150...500 A)EF750 (250...800 A)EF1250DU(350...1250 A)Manual motor startersThermal / magneticprotectionClass 10MS116 (0.10...32 A)Ics up to 50 kA for class 10AMS116 (0.10...32 A)lcs up to 50 kA for class 10AMS165(10...80 A)lcs up to 100 kAMS132 (0.10...32 A)Ics up to 100 kAMS132 (0.10...32 A)lcs up to 100 kAMagnetic only typesMO132 (0.16...32A)MO132 (0.16...32 A)Ics up to 100 kAMO165(16...80 A)lcs up to 100 kAAccessoriesFor contactor mountingBEA7/132BEA16-3BEA16-4BEA38-4BEA65-4 (4)(4) BEA65-4 suitable for MS165 and MO165 only.01
1/22ABB MOTOR PROTECTION AND CONTROL4-pole contactorsContactor relaysSpecific contactorsMini contactorsContactorsIECAC-1 Rated operational current θ ≤ 40 °C, 690 VA162025304555701001251602002753504005005258001000UL/CSAGeneral use rating600 VA12 (300 V)16253045556080105160175230250300350420540—AC / DC Control supplyTy pe——AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370——AC Control supplyTy peB6B7AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000DC Control supplyTy peBC6BC7AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000Mini contactor relaysContactor relaysIECAC-15 Rated operational current 400 VA333UL/CSAPilot dutyA600A600, Q300A600, Q6002 23 14 02 23 14 02 23 14 0AC Control supplyTy peK6-22ZK6-31ZK6-40ENS22ENS31ENS40ENF22ENF31ENF40EDC Control supplyTy peKC6-22ZKC6-31ZKC6-40ENSL22ENSL31ENSL40ENF22ENF31ENF40EAC / DC Control supplyTy pe——————NF22ENF31ENF40EDC Circuit switchingCapacitor switching100 A, 440 V, DC-1GA75, GAE75 types275 to 2050 A, 1000 V, DC-1GAF185 to GAF2050 types12.5 to 80 kvarUA16..RA to UA110..RA typesUA16 to UA110 types—General overview motor protection and control01
ABB MOTOR PROTECTION AND CONTROL 1/23Mini contactorsContactorsIECAC-1 Rated operational current θ ≤ 40 °C, 690 VA162025304555701001251602002753504005005258001000UL/CSAGeneral use rating600 VA12 (300 V)16253045556080105160175230250300350420540—AC / DC Control supplyTy pe——AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370——AC Control supplyTy peB6B7AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000DC Control supplyTy peBC6BC7AF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000Mini contactor relaysContactor relaysIECAC-15 Rated operational current 400 VA333UL/CSAPilot dutyA600A600, Q300A600, Q6002 23 14 02 23 14 02 23 14 0AC Control supplyTy peK6-22ZK6-31ZK6-40ENS22ENS31ENS40ENF22ENF31ENF40EDC Control supplyTy peKC6-22ZKC6-31ZKC6-40ENSL22ENSL31ENSL40ENF22ENF31ENF40EAC / DC Control supplyTy pe——————NF22ENF31ENF40EDC Circuit switchingCapacitor switching100 A, 440 V, DC-1GA75, GAE75 types275 to 2050 A, 1000 V, DC-1GAF185 to GAF2050 types12.5 to 80 kvarUA16..RA to UA110..RA typesUA16 to UA110 types01
— For more information please find our electronic data sheets online, for example:www.abb.com/productdetails/MS116-0.16 www.abb.com/productdetails/1SAM250000R1001or
—Manual motor starters & circuit breakers for transformer protection02Manual motor starters2/3 Presentation2/8 OverviewWith thermal and electromagnetic protection Ordering details - 0.10 to 80 A2/10 MS116 manual motor starters2/11 MS132 manual motor starters2/12 MS132-K manual motor starters with Push-in Spring terminals2/13 MS165 manual motor startersWith electromagnetic protection Ordering details - 0.16 to 80 A2/14 MO132 manual motor starters magnetic only2/15 MO165 manual motor starters magnetic only2/16 Technical data2/28 Circuit breakers for transformer protectionWith thermal and electromagnetic protection Ordering details - 0.10 to 25 A 2/29 MS132-T circuit breakers for transformer protection2/30 MS132-KT circuit breakers for transformer protection with Push-in Spring terminals2/31 Technical data2/34 AccessoriesABB MOTOR PROTECTION AND CONTROL 2/1
2/2ABB MOTOR PROTECTION AND CONTROL02
ABB MOTOR PROTECTION AND CONTROL 2/32CDC131093C0201—MS and MO manual motor startersA complete motor protection conceptFuseless protection saves costs, space and ensures a quick reaction under overload and short-circuit condition by switching off the motor within milliseconds. The full range of motor starters offers protection from 0.1 A to up to 100 A. The new family range has a harmonized range of accessories and offers the same features up to 80 A.Protection and controlProtect equipment and installationsABB offers a broad range of manual motor starters, for protection and control in almost every situation including hazardous areas, protecting installations from short-circuits, overloads and phase failures while also controlling the current flow through a simple ON/OFF switch.Continuous operationSecure uptimeFuseless motor protection reduces maintenance costs and downtimes by avoiding fuse replace-ment after faults. Furthermore, MS132 and MS165 feature a magnetic trip indicator making trouble-shooting easier. Speed up your projectsSimplified designManual motor starters can be connected easily with ABB contactors or soft starters using the respective accessory. Additionally, the main range of accessories is shared across multiple starters (both with screw and Push-in Spring terminals available), making logistics and planning simpler. 02
2/4 ABB MOTOR PROTECTION AND CONTROLIE3Ready for IE3 motorsMS116/MS132/MO132/MS165/MO165 comply with the latest standards. They are "IE3 ready" and will protect the new generation of high efficiency motors.Protection wherever you areManual motor starters are suitable for worldwide use. The wide range of certi-fications covers standards like IEC (CB), cULus, CCC, EAC and various ship ap-provals. MS132 and MS165 also apply to ATEX standards for hazardous areas.Just push itWith the new Push-in Spring terminals, one push is all you need for a faster than ever installation, an easier than ever wiring and a reliable as ever con-nection.—MS and MO manual motor startersA complete motor protection conceptLRDNVRinaABSBVFranceGLGermanyLRG r. B r itainDNVNorwayRINaItalyABSUSAAll-in-one ABB offers fuseless protection against short-circuits, phase failures and overloads including disconnect function – all in one single compact product.High performance in compact sizeMS132 and MS165 manual motor starters cover short-circuit breaking capacities up to 100 kA. In addition, every manual motor starter is temperature compen-sated up to 60 °C.Right solution for your applicationMS116 offers protection up to 32 A and a breaking capacity up to 100 k A – all in a 45 mm wide housing. They are designed to meet requirements of most standard applications.Troubleshooting made easyMS132 and MS165 feature a magnetic trip indicator. This way, every tripping event will be distin-guished, making troubleshooting a lot easier and faster.02
—Protection and controlThe right accessories for your applicationsEasy to connectSave wiring time and avoid mistakes by using a connecting link between ABB manual motor starters and soft starters or contactors. This creates harmonious and compact starter combinations that are easy to mount.Safety at workWith a lockable handle maintenance will be safe for every technician. For MS132 and MS165 a lock can seal the handle without the need for an additional accessory.Busbar connectors and enclosuresWith busbar connectors, up to 5 manual motor starters can be fitted next to each other with optional spacing for auxiliary contacts. Enclosures or door handle kits are available as well.Up to 5 manual motor starters can be fitted next to each otherWith a lockable handle maintenance will be safe for every technicianSave wiring time and avoid mistakes by using a connecting linkMS116MO132UA1SK1HK1AA1MO165HKF1Harmonized range of accessoriesAll types up to 80 A share the same main accessories like auxiliary contacts, signaling contacts, shunt trips and undervoltage releases. This significantly reduces the part list and makes selec-tion of the right accessories easy. ABB MOTOR PROTECTION AND CONTROL 2/52CDC131067C0202_NC02
—Application examplesMotor protectionStarter protectionNo matter what type of starter is required by the application (direct-on-line, star-delta, soft starter or variable frequency drive), MS and MO manual motor starters (also known as motor protection circuit breakers or manual motor protectors) are the right protection devices for electric motors from 100 mA up to 100 A.Circuit protection and controlABB’s manual motor starters are fuseless circuit breakers (approved acc. to IEC60947-2) that can be used to control circuits and protect cables / lines in industrial and commercial applications from overloads and short-circuits. The built-in disconnect function allows the usage as main On-/Off-switch, typically for de-centralized applications (e.g. small machinery or laboratory systems).MO (magnetic-only) manual motor starters are typically used, when motor overload protection is provided by a separate overload protection device. This setup is specially beneficial for applications that require auto- or remote-reset of the starter in case of an overload tripping event (e.g. windmills or HVAC fans).2/6 ABB MOTOR PROTECTION AND CONTROL2CDC131067C0202_NC02
Resistive loadsDC loadsExtreme conditionsRegardless if high-altitudes, shock and vibration environ-ments or hazardous areas, ABB’s manual motor starters are designed and certified to withstand harsh conditions. Specific versions for rolling stock applications are part of our offer. Manual motor starters are not only for motors!They are also an efficient solution for AC-1 applications, where it is required to protect and switch resistive loads (for example resistive furnaces or heaters).Manual motor starters are not only for AC applications!MS132 and MS165 manual motor starters are also rated for direct current loads (e.g. for motors used in solar panel tracking systems). ABB MOTOR PROTECTION AND CONTROL 2/72CDC131067C0202_NC02
2/8ABB MOTOR PROTECTION AND CONTROL—Manual motor startersOverviewTable for short-circuit ratings for 400/415 V ACStandard rangePerformance rangePerformance rangeTransformer protectionMS116MS132, MS165 MO132, MO165MS132-TSelection parametersRated operational powerSetting range for thermal releaseTy peShort-circuit breaking capacityTypeShort-circuit breaking capacityTy peShort-circuitbreaking capacityTypeShort-circuit breakingcapacityIcuIcsIcuIcsIcuIcsIcu/ Ics0.03 kW (1)0.1 ... 0.16 AMS116-0.16100 kA50 kAMS132-0.16 (2)100 kA100 kAMO132-0.16100 kA100 kAMS132-0.16T (2)100 kA0.06 kW0.16 ... 0.25 AMS116-0.25100 kA50 kAMS132-0.25 (2)100 kA100 kAMO132-0.25100 kA100 kAMS132-0.25T (2)100 kA0.09 kW0.25 ... 0.4 AMS116-0.4100 kA50 kAMS132-0.4 (2)100 kA100 kAMO132-0.4100 kA100 kAMS132-0.4T (2)100 kA0.18 kW0.4 ... 0.63 AMS116-0.63100 kA50 kAMS132-0.63 (2)100 kA100 kAMO132-0.63100 kA100 kAMS132-0.63T (2)100 kA0.25 kW0.63 ... 1.0 AMS116-1.0100 kA50 kAMS132-1.0 (2)100 kA100 kAMO132-1.0100 kA100 kAMS132-1.0T (2)100 kA0.55 kW1.0...1.6 AMS116-1.6100 kA50 kAMS132-1.6 (2)100 kA100 kAMO132-1.6100 kA100 kAMS132-1.6T (2)100 kA0.75 kW1.6...2.5 AMS116-2.575 kA50 kAMS132-2.5 (2)100 kA100 kAMO132-2.5100 kA100 kAMS132-2.5T (2)100 kA1.5 kW2.5...4.0 AMS116-4.075 kA50 kAMS132-4.0 (2)100 kA100 kAMO132-4.0100 kA100 kAMS132-4.0T (2)100 kA2.2 kW4.0...6.3 AMS116-6.350 kA50 kAMS132-6.3 (2)100 kA100 kAMO132-6.3100 kA100 kAMS132-6.3T (2)100 kA4.0 kW6.3...10 AMS116-1010 kA50 kAMS132-10 (2)100 kA100 kAMO132-10100 kA100 kAMS132-10T (2)100 kA5.5 kW8...12 AMS116-1250 kA25 kAMS132-12 100 kA100 kAMO132-12100 kA100 kAMS132-12T100 kA7.5 kW10...16 AMS116-1616 kA16 kAMS132-16 (2) / MS165-16100 kA100 kAMO132-16 / MO165-16100 kA100 kAMS132-16T (2)100 kA7.5 kW14 ... 20 AMS165-20100 kA100 kAMO165-20100 kA100 kA7.5 kW16...20 AMS116-2016 kA10 kAMS132-20 (2)100 kA100 kAMO132-20100 kA100 kAMS132-20T (2)100 kA11 kW18 ... 25 AMS165-25100 kA100 kA11 kW20...25 AMS116-2516 kA10 kAMS132-25 (2)50 kA50 kAMO132-25 / MO165-2550 kA / 100 kA50 kA / 100 kAMS132-25T (2)50 kA15 kW25...32 AMS116-3216 kA10 kAMS132-32 (2)50 kA25 kAMO132-3250 kA25 kATransformer protection:The instantaneous short-circuit currentsetting is 20 times the rated operational current.15 kW23 ... 32 AMS165-32100 kA100 kAMO165-32100 kA100 kA22 kW30 ... 42 AMS165-4250 kA50 kAMO165-4250 kA50 kA22 kW40 ... 54 AMS165-5450 kA30 kAMO165-5450 kA30 kA25 kW-30 kW52 ... 65 AMS165-6550 kA30 kAMO165-6550 kA30 kA37 kW62 ... 73 AMS165-7330 kA30 kAMO165-7330 kA30 kA45 kW70 ... 80 AMS165-8030 kA30 kAMO165-8030 kA30 kA(1) 690 V AC(2) Available with Push-in Spring terminals.Ty p eMS116MS132MS165MO132MO165MS132-TThermal and electromagnetic protectionYesYesYes--YesElectromagnetic protection ---YesYes-Phase loss sensitivityYesYesYes--YesSwitch positionON/OFFON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPMagnetic trip indication-YesYes--YesLockable handle without accessories-YesYesYesYesYesDisconnecting featureYesYesYesYesYesYesWidth45 mm45 mm55 mm45 mm55 mm45 mmRated operational current Ie0.10 ... 32 A0.10 ... 32 A10 ... 80 A0.16 ... 32 A16 ... 80 A0.16 ... 25 ASetting range0.10 ... 32 A0.10 ... 32 A10 ... 80 A--0.10 ... 25 AAmbient air temperature-25 ... +55 °C (1)-25 ... +60 °C (1)-25 ... +60 °C (1)-25 ... +60 °C-25 ... +60 °C-25 ... +60 °C (1)(1) CompensatedAccessoriesAuxiliary contact HKF1, HK1HKF1, HK1HKF1, HK1Signaling contactfor tripped alarm SK1SK1SK1for short-circuit alarm-CK1-CK1Shunt tripAA1AA1AA1Undervoltage releaseUA1UA1UA102
2CDC131112C0201 ABB MOTOR PROTECTION AND CONTROL 2/9Table for short-circuit ratings for 400/415 V ACStandard rangePerformance rangePerformance rangeTransformer protectionMS116MS132, MS165 MO132, MO165MS132-TSelection parametersRated operational powerSetting range for thermal releaseTy peShort-circuit breaking capacityTypeShort-circuit breaking capacityTy peShort-circuit breaking capacityTypeShort-circuit breaking capacityIcuIcsIcuIcsIcuIcsIcu / Ics0.03 kW (1)0.1 ... 0.16 AMS116-0.16100 kA50 kAMS132-0.16 (2)100 kA100 kAMO132-0.16100 kA100 kAMS132-0.16T (2)100 kA0.06 kW0.16 ... 0.25 AMS116-0.25100 kA50 kAMS132-0.25 (2)100 kA100 kAMO132-0.25100 kA100 kAMS132-0.25T (2)100 kA0.09 kW0.25 ... 0.4 AMS116-0.4100 kA50 kAMS132-0.4 (2)100 kA100 kAMO132-0.4100 kA100 kAMS132-0.4T (2)100 kA0.18 kW0.4 ... 0.63 AMS116-0.63100 kA50 kAMS132-0.63 (2)100 kA100 kAMO132-0.63100 kA100 kAMS132-0.63T (2)100 kA0.25 kW0.63 ... 1.0 AMS116-1.0100 kA50 kAMS132-1.0 (2)100 kA100 kAMO132-1.0100 kA100 kAMS132-1.0T (2)100 kA0.55 kW1.0...1.6 AMS116-1.6100 kA50 kAMS132-1.6 (2)100 kA100 kAMO132-1.6100 kA100 kAMS132-1.6T (2)100 kA0.75 kW1.6...2.5 AMS116-2.575 kA50 kAMS132-2.5 (2)100 kA100 kAMO132-2.5100 kA100 kAMS132-2.5T (2)100 kA1.5 kW2.5...4.0 AMS116-4.075 kA50 kAMS132-4.0 (2)100 kA100 kAMO132-4.0100 kA100 kAMS132-4.0T (2)100 kA2.2 kW4.0...6.3 AMS116-6.350 kA50 kAMS132-6.3 (2)100 kA100 kAMO132-6.3100 kA100 kAMS132-6.3T (2)100 kA4.0 kW6.3...10 AMS116-1010 kA50 kAMS132-10 (2)100 kA100 kAMO132-10100 kA100 kAMS132-10T (2)100 kA5.5 kW8...12 AMS116-1250 kA25 kAMS132-12 100 kA100 kAMO132-12100 kA100 kAMS132-12T100 kA7.5 kW10...16 AMS116-1616 kA16 kAMS132-16 (2) / MS165-16100 kA100 kAMO132-16 / MO165-16100 kA100 kAMS132-16T (2)100 kA7.5 kW14 ... 20 AMS165-20100 kA100 kAMO165-20100 kA100 kA7.5 kW16...20 AMS116-2016 kA10 kAMS132-20 (2)100 kA100 kAMO132-20100 kA100 kAMS132-20T (2)100 kA11 kW18 ... 25 AMS165-25100 kA100 kA11 kW20...25 AMS116-2516 kA10 kAMS132-25 (2)50 kA50 kAMO132-25 / MO165-2550 kA / 100 kA50 kA / 100 kAMS132-25T (2)50 kA15 kW25...32 AMS116-3216 kA10 kAMS132-32 (2)50 kA25 kAMO132-3250 kA25 kATransformer protection: The instantaneous short-circuit current setting is 20 times the rated operational current.15 kW23 ... 32 AMS165-32100 kA100 kAMO165-32100 kA100 kA22 kW30 ... 42 AMS165-4250 kA50 kAMO165-4250 kA50 kA22 kW40 ... 54 AMS165-5450 kA30 kAMO165-5450 kA30 kA25 kW-30 kW52 ... 65 AMS165-6550 kA30 kAMO165-6550 kA30 kA37 kW62 ... 73 AMS165-7330 kA30 kAMO165-7330 kA30 kA45 kW70 ... 80 AMS165-8030 kA30 kAMO165-8030 kA30 kA(1) 690 V AC(2) Available with Push-in Spring terminals.Ty p eMS116MS132MS165MO132MO165MS132-TThermal and electromagnetic protectionYesYesYes--YesElectromagnetic protection ---YesYes-Phase loss sensitivityYesYesYes--YesSwitch positionON/OFFON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPON/OFF/TRIPMagnetic trip indication-YesYes--YesLockable handle without accessories-YesYesYesYesYesDisconnecting featureYesYesYesYesYesYesWidth45 mm45 mm55 mm45 mm55 mm45 mmRated operational current Ie0.10 ... 32 A0.10 ... 32 A10 ... 80 A0.16 ... 32 A16 ... 80 A0.16 ... 25 ASetting range0.10 ... 32 A0.10 ... 32 A10 ... 80 A--0.10 ... 25 AAmbient air temperature-25 ... +55 °C (1)-25 ... +60 °C (1)-25 ... +60 °C (1)-25 ... +60 °C-25 ... +60 °C-25 ... +60 °C (1)(1) CompensatedAccessoriesAuxiliary contact HKF1, HK1HKF1, HK1HKF1, HK1Signaling contactfor tripped alarm SK1SK1SK1for short-circuit alarm-CK1-CK1Shunt tripAA1AA1AA1Undervoltage releaseUA1UA1UA102
2CDC131062C02012/10ABB MOTOR PROTECTION AND CONTROL—MS116 manual motor starters0.10 to 32 A – with thermal and electromagnetic protectionMS116 is a compact and economic range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks and locking devices for pro-tection against unauthorized changes are available as accessory. These are suitable throughout the MS116/MS132/MS165-range.Rated operational power400 V Setting rangeShort-circuit breakingcapacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)AC-3kWAkAAkg0.03 (1)0.10 ... 0.16502.00 MS116-0.161SAM250000R10010.2250.060.16 ... 0.25 503.10 MS116-0.251SAM250000R10020.2250.090.25 ... 0.40505.00 MS116-0.41SAM250000R10030.2250.180.40 ... 0.63 507.90 MS116-0.631SAM250000R10040.2250.250.63 ... 1.00 5012.5 MS116-1.01SAM250000R10050.2250.551.00 ... 1.60 5020.0MS116-1.61SAM250000R10060.2650.751.60 ... 2.50 5031.3 MS116-2.51SAM250000R10070.2651.502.50 ... 4.00 5050.0MS116-4.01SAM250000R10080.2652.204.00 ... 6.30 5078.8MS116-6.31SAM250000R10090.2654.006.30 ... 10.0 50150MS116-101SAM250000R10100.2655.508.00 ... 12.0 25180MS116-12 1SAM250000R1012 0.2657.5010.0 ... 16.0 16240MS116-161SAM250000R10110.2657.5016.0 ... 20.010300MS116-201SAM250000R10130.31011.020.0 ... 25.010375MS116-251SAM250000R10140.31015.025.0 ... 32.010480MS116-321SAM250000R10150.310Mounted Auxiliary Contacts 1 N.O. + 1 N.C.0.03 (1)0.10 ... 0.16502.00 MS116-0.16-HKF1-111SAM250005R10010.2400.060.16 ... 0.25 503.10 MS116-0.25-HKF1-111SAM250005R10020.2400.090.25 ... 0.40505.00 MS116-0.4-HKF1-111SAM250005R10030.2400.180.40 ... 0.63 507.90 MS116-0.63-HKF1-111SAM250005R10040.2400.250.63 ... 1.00 5012.5MS116-1.0-HKF1-111SAM250005R10050.2400.551.00 ... 1.60 5020.0MS116-1.6-HKF1-111SAM250005R10060.2800.751.60 ... 2.50 5031.3 MS116-2.5-HKF1-111SAM250005R10070.2801.502.50 ... 4.00 5050.0MS116-4.0-HKF1-111SAM250005R10080.2802.204.00 ... 6.30 5078.8MS116-6.3-HKF1-111SAM250005R10090.2804.006.30 ... 10.0 50150MS116-10.0-HKF1-111SAM250005R10100.2805.508.00 ... 12.0 25180MS116-12.0-HKF1-111SAM250005R10120.2807.5010.0 ... 16.0 16240MS116-16.0-HKF1-111SAM250005R10110.2807.5016.0 ... 20.010300MS116-20-HKF1-111SAM250005R10130.32611.020.0 ... 25.010375MS116-25-HKF1-111SAM250005R10140.32615.025.0 ... 32.010480MS116-32-HKF1-111SAM250005R10150.326Note: Manual motor starters should always be selected so that the actual motor current is within the setting range.(1) 690 V2CDC241004V0017MS116-16MS116-252CDC241019V0017MS116-0.16-HKF1-112CDC241020V0017MS116-32-HKF1-11Main dimensions mm, inches0.06"0.07"0.55"3.54"1.77"0.55"1.38"0.22"1.77"2.3"2.76"1.71"3.15"1.1"2.95"1.5 1.7 14 14 90 45 35 5.5 45 57.8 70 43.5 80.1 27.5 75 MS116 ≤ 16 A & MS116-HKF1-11 ≤ 16 AMS116 ≥ 20 A & MS116-HKF1-11 ≥ 20 A1.77"2.3"1.38"0.22"2.75"1.7"3.15"0.55"2.95"3.85"1.77"0.55"0.06"0.07"1.1"45 57.8 35 5.5 69.8 43.3 79.9 14 14 75 97.8 45 1.5 1.7 27.5 2CDC241017V001702
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/11—MS132 manual motor starters0.10 to 32 A – with thermal and electromagnetic protectionMS132 is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165-range.Rated operational power400 V Setting rangeShort-circuit breaking capacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy peOrder codeWeight(1 pce)AC-3kWAkAAkg0.03 (1)0.10 ... 0.161002.00MS132-0.161SAM350000R10010.2150.060.16 ... 0.251003.10MS132-0.251SAM350000R10020.2150.090.25 ... 0.401005.00MS132-0.41SAM350000R10030.2150.180.40 ... 0.631007.90MS132-0.631SAM350000R10040.2150.250.63 ... 1.0010012.5MS132-1.01SAM350000R10050.2150.551.00 ... 1.6010020.0MS132-1.61SAM350000R10060.2650.751.60 ... 2.5010031.3MS132-2.51SAM350000R10070.2651.502.50 ... 4.0010050.0MS132-4.01SAM350000R10080.2652.204.00 ... 6.3010078.8MS132-6.31SAM350000R10090.2654.006.30 ... 10.0100150MS132-101SAM350000R10100.2655.508.00 ... 12.0100180MS132-121SAM350000R10120.3107.5010.0 ... 16.0100240MS132-161SAM350000R10110.3107.5016.0 ... 20.0100300MS132-201SAM350000R10130.31011.020.0 ... 25.050375MS132-251SAM350000R10140.31015.025.0 ... 32.025480MS132-321SAM350000R10150.310Mounted Auxiliary Contacts 1 N.O. + 1 N.C.0.03 (1)0.10 ... 0.161002.00MS132-0.16-HKF1-111SAM350005R10010.2310.060.16 ... 0.25 1003.10MS132-0.25-HKF1-111SAM350005R10020.2310.090.25 ... 0.401005.0MS132-0.4-HKF1-111SAM350005R10030.2310.180.40 ... 0.63 1007.90MS132-0.63-HKF1-111SAM350005R10040.2310.250.63 ... 1.00 10012.5MS132-1.0-HKF1-111SAM350005R10050.2310.551.00 ... 1.60 10020.0MS132-1.6-HKF1-111SAM350005R10060.2810.751.60 ... 2.50 10031.3MS132-2.5-HKF1-111SAM350005R10070.2811.502.50 ... 4.00 10050.0MS132-4.0-HKF1-111SAM350005R10080.2812.204.00 ... 6.30 10078.8MS132-6.3-HKF1-111SAM350005R10090.2814.006.30 ... 10.0 100150MS132-10.0-HKF1-111SAM350005R10100.2815.508.00 ... 12.0 100180MS132-12.0-HKF1-111SAM350005R10120.3267.5010.0 ... 16.0 100240MS132-16.0-HKF1-111SAM350005R10110.3267.5016.0 ... 20.0100300MS132-20-HKF1-111SAM350005R10130.32611.020.0 ... 25.050375MS132-25-HKF1-111SAM350005R10140.32615.025.0 ... 32.025480MS132-32-HKF1-111SAM350005R10150.326Mounted Auxiliary Contacts 2 N.O. + 0 N.C.7.5010 ... 16100240MS132-16-HKF1-201SAM350006R10110.326Note: Manual motor starters should always be selected so that the actual motor current is within the setting range.(1) 690 V2CDC241002V0013MS132-102CDC241006V0017MS132-32MS132-0.16-HKF1-11MS132-32-HKF1-11 1.38" 0.1" 3.54" 2.95" 0.22" 0.06" 0.55" 1.77" 0.55" 2.85" 3.2" 1.71" 1.77" 35 1.7 90 755.51.5 14 45 14 72.4 81.25 43.5 45" 0.06"0.22"0.22"2.84" 3.19"0.1"3.85"1.77" 0.55" 0.55" 1.77" 2.95"1.38"1.5 5.5 43.3 72.2 81.05 1.797.8 45 14 14 45 75 35MS132 ≤ 10 AMS132 ≥ 12 AMain dimensions mm, inches2CDC241021V001702
2CDC131062C02012/12ABB MOTOR PROTECTION AND CONTROL—MS132-K manual motor starters with Push-in Spring terminals0.10 to 32 A – with thermal and electromagnetic protection81 3.19"72.5 2.85"43.5 1.71"5.5 0.22"45 1.77"90 3.54"45 1.77"112 4.41"35mm EN/EC 60715The MS132-K series is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A with a width of only 45 mm. The innovative Push-in Spring terminals enable tool-free wiring and eliminate the need for routine re-tightening. The MS132-K also has a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165-range.Rated operational power 400 V AC-3Setting rangeShort-circuit breaking capacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy peOrder codeWeight (1 pce)kWAkAAkg0.03(1)0.10 ... 0.161002.00MS132-0.16K1SAM350010R10010.2560.060.16 ... 0.251003.10MS132-0.25K1SAM350010R10020.2560.090.25 ... 0.401005.00MS132-0.4K1SAM350010R10030.2560.180.40 ... 0.631007.90MS132-0.63K1SAM350010R10040.2560.250.63 ... 1.0010012.5MS132-1.0K1SAM350010R10050.2560.551.00 ... 1.6010020.0MS132-1.6K1SAM350010R10060.2980.751.60 ... 2.5010031.3MS132-2.5K1SAM350010R10070.2801.502.50 ... 4.0010050.0MS132-4.0K1SAM350010R10080.2862.204.00 ... 6.3010078.8MS132-6.3K1SAM350010R10090.2894.006.30 ... 10.0100150MS132-10K1SAM350010R10100.2967.5010.0 ... 16.0100240MS132-16K1SAM350010R10110.3167.5016.0 ... 20.0100300MS132-20K1SAM350010R10130.31711.020.0 ... 25.050375MS132-25K1SAM350010R10140.31615.025.0 ... 32.025480MS132-32K1SAM350010R10150.316Note: Manual motor starters should always be selected so that the actual motor current is within the setting range.(1) 690 V2CDC241025V0017MS132-K > 10 AMS132-K ≤ 10 A81 3.19"72.5 2.85"43.5 1.71"5.5 0.22"45 1.77"90 3.54"45 1.77"112 4.41"35mm EN/EC 60715Main dimensions mm, inchesMS132-32K02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/13—MS165 manual motor starters10 to 80 A – with thermal and electromagnetic protectionMS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165-range.Rated operational power400 V Setting rangeShort-circuit breakingcapacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)AC-3kWAkAAkg7.510 ... 16100240MS165-161SAM451000R10110.9507.514 ... 20 100300MS165-201SAM451000R10120.9501118 ... 25 100375MS165-251SAM451000R10130.9601523 ... 32 100480MS165-321SAM451000R10140.9702230 ... 4250630MS165-421SAM451000R10150.9702240 ... 5430810MS165-541SAM451000R10160.9703052 ... 6530975MS165-651SAM451000R10170.9803762 ... 73301022MS165-731SAM451000R10181.0004570 ... 80301120MS165-801SAM451000R10191.000Note: Manual motor starters should always be selected so that the actual motor current is within the setting range.MS165-655517.5 17.5 95.5 122.15.593.51061.75142.65 3576.3544.9 2.052.17"0.69"0.69"3.76"4.81"0.22"3.68"4.17"0.07"5.62"1.38" 3.01" 1.77"0.08"MS165Main dimensions mm, inches2CDC241007V001702
2CDC131062C02012/14ABB MOTOR PROTECTION AND CONTROL—MO132 manual motor starters magnetic only0.16 to 32 A – with electromagnetic protectionThe MO132 manual motor starter magnetic only is a compact and powerful range for motor protection up to 15 kW (400 V AC) in width of 45 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits.The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase busbars and power in-feed blocks are available as accessory.Rated operational power400 V AC-3Rated operationalcurrentShort-circuit breaking capacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)kWAkAAkg0.03 (1)0.161002.00MO132-0.161SAM360000R10010.2150.060.251003.10MO132-0.251SAM360000R10020.2150.090.401005.00MO132-0.41SAM360000R10030.2150.120.631007.90MO132-0.631SAM360000R10040.2150.251.010012.5MO132-1.01SAM360000R10050.2150.551.610020.0MO132-1.61SAM360000R10060.2650.752.510031.3MO132-2.51SAM360000R10070.2651.54.010050.0MO132-4.01SAM360000R10080.2652.26.310078.8MO132-6.31SAM360000R10090.2654.010100125MO132-101SAM360000R10100.2655.512100150MO132-121SAM360000R10120.3107.516100200MO132-161SAM360000R10110.3107.520100250MO132-201SAM360000R10130.310112550313MO132-251SAM360000R10140.310153225400MO132-321SAM360000R10150.310Note: For overload protection of motors, an appropriate thermal or electronic overload relay must be used.(1) 690 V2CDC241018V0017MO132-6.32CDC241015V0017MO132-32 1.38" 0.1" 3.54" 2.95" 0.22" 0.06" 0.55" 1.77" 0.55" 2.85" 3.2" 1.71" 1.77" 35 1.7 90 755.51.5 14 45 14 72.4 81.25 43.5 45" 0.06"0.22"0.22"2.84" 3.19"0.1"3.85"1.77" 0.55" 0.55" 1.77" 2.95"1.38"1.5 5.5 43.3 72.2 81.05 1.797.8 45 14 14 45 75 35MO132 ≤ 10 AMO132 ≥ 12 AMain dimensions mm, inches02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/15—MO165 manual motor starters magnetic only16 to 80 A – with electromagnetic protectionThe MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V AC) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mecha-nism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.Rated operational power400 V Rated operational currentShort-circuit breaking capacity Ics at 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)AC-3kWAkAAkg7.516100240MO165-161SAM461000R10110.9507.520100300MO165-201SAM461000R10120.9501125100375MO165-251SAM461000R10130.9601532100480MO165-321SAM461000R10140.970224250630MO165-421SAM461000R10150.970225430810MO165-541SAM461000R10160.970306530975MO165-651SAM461000R10170.9803773301022MO165-731SAM461000R10181.0004580301120MO165-801SAM461000R10191.000Note: For overload protection of motors, an appropriate thermal or electronic overload relay must be used.MO165-655517.5 17.5 95.5 122.15.593.51061.75142.65 3576.3544.9 2.052.17"0.69"0.69"3.76"4.81"0.22"3.68"4.17"0.07"5.62"1.38" 3.01" 1.77"0.08"MO165Main dimensions mm, inches2CDC241008V001702
2CDC131062C02012/16ABB MOTOR PROTECTION AND CONTROL—MS116, MS132, MS165, MO132, MO165 Technical dataMain circuit – Utilization characteristics according to IEC/ENTy peMS116MS132MS165MO132MO165StandardsIEC/EN 60947–2, IEC/EN 60947-4-1, IEC/EN 60947-1Rated operational voltage Ue690 V AC690 V AC / 250 V DC690 V AC / 250 V DC690 V AC690 V AC / 250 V DCRated frequency50/60 HzDC, 50/60 HzDC, 50/60 Hz50/60 HzDC, 50/60 Hz Operational frequency50/60 Hz0 ... 400 Hz0 ... 400 Hz 0 ... 400 Hz0 ... 400 Hz Trip class10A1010––Number of poles3Duty time100%Mechanical durability100000 cycles100000 cycles50000 cycles100000 cycles50000 cyclesElectrical durabilityup to 10 A up to 100000 cyclesup to 100000 cyclesup to 25000 cyclesup to 100000 cyclesup to 50000 cyclesup to 16 A100000 cycles 50000 cycles25000 cycles50000 cycles25000 cycles20 ... 65 A50000 cycles50000 cycles25000 cycles50000 cycles25000 cycles65 ... 80 A ––20000 cycles–20000 cyclesRated impulse withstand voltage Uimp6 kV6 kV8 kV6 kV8 kVRated insulation voltage Ui690 V690 V1000 V690 V1000 VRated operational current IeSee ordering detailsRated operational current DC-5 Ie3 conducting paths in series up to 250 V–See "Rated operational current Ie"See "Rated operational current Ie"–See "Rated operational current Ie"Rated instantaneous short-circuit current setting IiSee ordering detailsRated service short-circuit breaking capacity IcsSee table "Short-circuit breaking capacity and back-up fuses"Rated ultimate short-circuit breaking capacity IcuSee table "Short-circuit breaking capacity and back-up fuses"Rated service short-circuit breaking capacity DC Ics3 conducting paths in series up to 250 V–10 kA100 kA –100 kA Short-circuit breaking capacity and back-up fuseslcsRated service short-circuit breaking capacitylcuRated ultimate short-circuit breaking capacityIccProspective short-circuit current at installation locationNote: Maximum rated current of the back-up fuses if Icc > IcsTy pe230 V AC 400 V AC440 V AC500 V AC690 V ACIcs IcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMkAkAAkAkAAkAkAAkAkAAkAkAAMS116-0.1650100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-0.2550100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-0.450100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-0.6350100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-1.050100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-1.650100- (1)50100- (1)30100- (1)30100- (1)30100- (1)MS116-2.55075- (1)5075- (1)103025 (2)102025 (2)51025 (2)MS116-4.05075- (1)5075- (1)61825 (2)61525 (2)2325 (2)MS116-6.35050- (1)5050- (1)61863 (2) 61063 (2)2340 (2)MS116-105050- (1)5050- (1)61863 (2)61063 (2)2350 (2)MS116-12 255080 (2)255080 (2)61563 (2)61063 (2)2350 (2)MS116-16161680 (2)161680 (2)61563 (2)41063 (2)2363 (2)MS116-201016125 (2)1016125 (2) 315125 (2) 310125 (2) 2380 (2)MS116-251016125 (2)1016125 (2) 315125 (2) 310125 (2) 23100 (2)MS116-321016125 (2)1016125 (2) 315125 (2) 310125 (2) 23100 (2)(1) No back-up fuse required, because short-circuit proof up to 50 k A(2) Rated back-up fuse for short-circuit up to 50 k A02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/17—MS116, MS132, MS165, MO132, MO165 Technical dataShort-circuit breaking capacity and back-up fusesTy pe230 V AC 400 V AC440 V AC500 V AC690 V ACIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMkAkAAkAkAAkAkAAkAkAAkAkAAMS132-0.16100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.25100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.4100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.63100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-1.0100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-1.6100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-2.5100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-4.0100100- (1)100100- (1)303035 (2)202035 (2)3332 (2)MS132-6.3100100- (1)100100- (1)303063 (2)202063 (2)3350 (2)MS132-10100100- (1)100100- (1)2020100 (2)2020100 (2) 3350 (2)MS132-12100100- (1)100100- (1)2020100 (2)2020100 (2) 3 3 63 (2)MS132-16100100- (1)100100- (1)2020125 (2)2020125 (2) 3363 (2)MS132-20100100- (1)100100- (1)2020125 (2)2020125 (2) 3380 (2)MS132-255050125 (2)5050125 (2)2020125 (2)1010125 (2) 33100 (2)MS132-322550125 (2)2550125 (2)2020125 (2)1010125 (2) 33100 (2)(1) No back-up fuse required, because short-circuit proof up to 100 k A(2) Rated back-up fuse for short-circuit up to 100 k ATy pe230 V AC 400 V AC440 V AC500 V AC690 V AC250 V DC (3)IcsIcugGIcsIcugGIcsIcugGIcsIcugGIcsIcugGIcsIcugG kAkAAkAkAAkAkAAkAkAAkAkAAkAkAAMS165-16100100- (1)100100- (1)7575125 (2)4040125 (2)101063 (2)100100- (1)MS165-20100100- (1)100100- (1)7575125 (2)4040125 (2)101063 (2)100100- (1)MS165-25100100- (1)100100- (1)5050125 (2)3030125 (2)101080 (2)100100- (1)MS165-32100100- (1)100100- (1)5050125 (2)3030125 (2)1010100 (2)100100- (1)MS165-425050125 (2)5050125 (2)5050125 (2)3030125 (2)1010100 (2)100100- (1)MS165-543050125 (2)3050125 (2)3045125 (2)2020125 (2) 68100 (2)100100- (1)MS165-653050125 (2)3050125 (2)3045125 (2)2020125 (2) 68100 (2)100100- (1)MS165-7330303030686868MS165-8030303030686868(1) No back-up fuse required, short-circuit proof up to 100 k A(2) Rated back-up fuse for short-circuit up to 100 k A(3) 3 poles in seriesTy pe230 V AC 400 V AC440 V AC500 V AC690 V ACIcs IcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMkAkAAkAkAAkAkAAkAkAAkAkAAMO132-0.16100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-0.25100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-0.4100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-0.63100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-1.0100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-1.6100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-2.5100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MO132-4.0100100- (1)100100- (1)303035 (2)202035 (2)3332 (2)MO132-6.3100100- (1)100100- (1)303063 (2)202063 (2)3350 (2)MO132-10100100- (1)100100- (1)2020100 (2)2020100 (2) 3350 (2)MO132-12100100- (1)100100- (1)2020100 (2)2020100 (2) 3363 (2)MO132-16100100- (1)100100- (1)2020125 (2)2020125 (2) 3363 (2)MO132-20100100- (1)100100- (1)2020125 (2)2020125 (2) 3380 (2)MO132-255050125 (2)5050125 (2)1010125 (2)1010125 (2) 33100 (2)MO132-322550125 (2)2550125 (2)1010125 (2)1010125 (2) 33100 (2)(1) No back-up fuse required, because short-circuit proof up to 100 k A(2) Rated back-up fuse for short-circuit up to 100 k A 02
2CDC131062C02012/18ABB MOTOR PROTECTION AND CONTROL—MS116, MS132, MS165, MO132, MO165 Technical dataShort-circuit breaking capacity and back-up fusesTy pe230 V AC 400 V AC440 V AC500 V AC690 V AC250 V DC (3)Ics IcugGIcsIcugGIcsIcugGIcsIcugGIcsIcugGIcsIcugGkAkAAkAkAAkAkAAkAkAAkAkAAkAkAAMO165-16100100- (1)100100- (1)7575125 (2)4040125 (2)101063 (2)100100- (1)MO165-20100100- (1)100100- (1)7575125 (2)4040125 (2)101063 (2)100100- (1)MO165-25100100- (1)100100- (1)5050125 (2)3030125 (2)101080 (2)100100- (1)MO165-32100100- (1)100100- (1)5050125 (2)3030125 (2)1010100 (2)100100- (1)MO165-425050125 (2)5050125 (2)5050125 (2)3030125 (2)1010100 (2)100100- (1)MO165-543050125 (2)3050125 (2)3045125 (2)2020125 (2) 68100 (2)100100- (1)MO165-653050125 (2)3050125 (2)3045125 (2)2020125 (2) 68100 (2)100100- (1)MO165-7330303030686868MO165-8030303030686868(1) No back-up fuse required, short-circuit proof up to 100 k A(2) Rated back-up fuse for short-circuit up to 100 k A(3) 3 poles in seriesMain circuit – Utilization characteristics according to UL/CSATy peMS116MS132MS165MO132MO165StandardsUL 60947-1, UL 60947-4-1 (UL 508), CSA C22.2 No.60947-4-1 (CSA C22.2 No.14)Rated operational voltage Ue acc. to UL/CSA600 V AC600 V AC600 V AC600 V AC600 V ACTrip class10A10-Motor ratings (1)HorsepowerSee table "Motor ratings, three phase"Full Load Amps (FLA)See table "Motor ratings, three phase"Locked Rotor Amps (LRA)See table "Motor ratings, three phase"(1) See product data sheets for UL/CSA single phase motor and general use ratings.UL/CSA ratings overviewTy peMS116MS132MS165MO132MO165Manual Motor ControllerxxxxxManual Motor Controller, Suitable as Motor DisconnectxxxxxManual Motor Controller, Suitable for use in Group InstallationsxxxxxManual Motor Controller, Suitable for Tap Conductor Protection in Group Installations-xxxxManual self-protected Combination Motor Controller (Type E)-xx (up to 65 A)--Combination Motor Controller (Type F)-with AF contactorwith AF contactor (up to 65 A)with AF contactor and EOLwith AF contactor and EOL (up to 65 A)02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/19—MS116, MS132, MS165, MO132, MO165 Technical dataUL/CSA Motor ratings, three phase – MS116Ty pe200 V AC208 V AC220 ... 240 V AC440 ... 480 V AC550 ... 600 V AChpFLALRAhpFLALRAhpFLALRAhpFLALRAhpFLALRAMS116-0.16-0.160.96-0.160.96-0.160.96-0.160.96-0.160.96MS116-0.25-0.251.5-0.251.5-0.251.5-0.251.5-0.251.5MS116-0.40-0.42.4-0.42.4-0.42.4-0.42.4-0.42.4MS116-0.63-0.633.78-0.633.78-0.633.78-0.633.78-0.633.78MS116-1.0-16-16-16-161/20.98MS116-1.6-1.69.6-1.69.6-1.69.63/41.69.63/41.69.6MS116-2.51/22.5151/22.5151/22.51512.5151 1/22.515MS116-4.03/44243/44241424242433.925.6MS116-6.316.337.816.337.81 1/26.337.834.83256.136.8MS116-1027.857.527.55539.66457.6467 1/2950.8MS116-1231173.6310.67139.6647 1/21163.5101164.8MS116-1631173.6310.671515.292101481101164.8MS116-20517.5105.8516.7102515.292101481151793MS116-25517.5105.87 1/224.21407 1/22212715211162022116MS116-327 1/225.31461030.8179102816220271452527146UL/CSA Motor ratings, three phase – MS132Ty pe200 V AC208 V AC220 ... 240 V AC440 ... 480 V AC550 ... 600 V AChpFLALRAhpFLALRAhpFLALRAhpFLALRAhpFLALRAMS132-0.16-0.160.96-0.160.96-0.160.96-0.160.96-0.160.96MS132-0.25-0.251.5-0.251.5-0.251.5-0.251.5-0.251.5MS132-0.40-0.42.4-0.42.4-0.42.4-0.42.4-0.42.4MS132-0.63-0.633.78-0.633.78-0.633.78-0.633.78-0.633.78MS132-1.0-16-16-16-161/216MS132-1.6-1.69.6-1.69.6-1.69.63/41.69.63/41.69.6MS132-2.51/22.5151/22.5151/22.51512.5151-1/22.515MS132-4.03/44243/44241424242433.925.6MS132-6.316.337.816.337.81 1/26.337.834.83256.136.8MS132-1027.857.527.55539.66457.6467 1/2950.8MS132-1231173.6310.67139.6647 1/21163.5101164.8MS132-1631173.6310.671515.292101481101164.8MS132-20517.5105.8516.7102515.292101481151793MS132-25517.5105.87 1/224.21407 1/22212715211162022116MS132-327 1/225.31461030.8179102816220271452527146UL/CSA Motor ratings, three phase – MS165Ty pe200 V AC208 V AC220 ... 240 V AC440 ... 480 V AC550 ... 600 V AChpFLALRAhpFLALRAhpFLALRAhpFLALRAhpFLALRAMS165-1631173.6310.671515.292101481101164.8MS165-20517.5105.8516.7102515.292101481151793MS165-25517.5105.87 1/224.21407 1/22212715211162022116MS165-327 1/225.31461030.8179102816220271453032174MS165-421032.2186.31030.8179154223230402184041232MS165-541548.32671546.2257205429040522905052290MS165-652062.13342059.4321205429050653636062348MS165-732062.13342059.4321256836550653636062348MS165-802578.24202574.8404308043560774357577434hp HorsepowerFLA Full Load AmpsLRA Locked Rotor AmpsNote: Manual motor starters should always be selected so that the actual motor current is within the setting range; see ordering detail pages. Horsepower (hp) ratings are for reference only.02
2CDC131062C02012/20ABB MOTOR PROTECTION AND CONTROLUL/CSA Motor ratings, three phase – MO132Ty pe200 V AC208 V AC220 ... 240 V AC440 ... 480 V AC550 ... 600 V AChpFLALRAhpFLALRAhpFLALRAhpFLALRAhpFLALRAMO132-0.16-0.160.96-0.160.96-0.160.96-0.160.96-0.160.96MO132-0.25-0.251.5-0.251.5-0.251.5-0.251.5-0.251.5MO132-0.40-0.42.4-0.42.4-0.42.4-0.42.4-0.42.4MO132-0.63-0.633.78-0.633.78-0.633.78-0.633.78-0.633.78MO132-1.0-16-16-16-161/216MO132-1.6-1.69.6-1.69.6-1.69.63/41.69.63/41.69.6MO132-2.51/22.5151/22.5151/22.51512.5151 1/22.515MO132-4.03/44243/44241424242433.925.6MO132-6.316.337.816.337.81 1/26.337.834.83256.136.8MO132-1027.857.527.55539.66457.6467 1/2950.8MO132-1231173.6310.67139.6647 1/21163.5101164.8MO132-1631173.6310.671515.292101481101164.8MO132-20517.5105.8516.7102515.292101481151793MO132-25517.5105.87 1/224.21407 1/22212715211162022116MO132-327 1/225.31461030.8179102816220271452527146UL/CSA Motor ratings, three phase – MO165Ty pe200 V AC208 V AC220 ... 240 V AC440 ... 480 V AC550 ... 600 V AChpFLALRAhpFLALRAhpFLALRAhpFLALRAhpFLALRAMO165-1631173.6310.671515.292101481101164.8MO165-20517.5105.8516.7102515.292101481151793MO165-25517.5105.87 1/224.21407 1/22212715211162022116MO165-327 1/225.31461030.8179102816220271453032174MO165-421032.2186.31030.8179154223230402184041232MO165-541548.32671546.2257205429040522905052290MO165-652062.13342059.4321205429050653636062348MO165-732062.13342059.4321256836550653636062348MO165-802578.24202574.8404308043560774357577434—MS116, MS132, MS165, MO132, MO165Technical data02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/21UL/CSA Maximum short-circuit current ratings – MS116Ty peManual Motor ControllersBranch circuit protection, max. size per NEC/CEC (1) for motor disconnect (2)for group installationsFusesCircuit breaker480 V600 V480 V600 VAAkAkAkAkAMS116-0.16Any listed fuses. Size per NEC/CECAny listed UL489 / CSA C22.2 N° 5 circuit breaker.Size per NEC/CEC305305MS116-0.25305305MS116-0.40305305MS116-0.63305305MS116-1.0305305MS116-1.6305305MS116-2.5305305MS116-4.0185185MS116-6.3185185MS116-10185185MS116-12185185MS116-16185185MS116-20185185MS116-25185185MS116-32185185(1) NEC: NFPA®70 National Electrical Code®; CEC: CSA C22.1 Canadian Electrical Code.(2) Suitable as motor disconnect with padlock adaptor SA1 or SA3.UL/CSA Maximum short-circuit current ratings – MS132Ty peManual Motor ControllersManual self-protected Combination Motor Controllers (Type E) (2)Branch circuit protection, max. size per NEC/CEC (1)for motor disconnectfor group installationsfor tap conductor protection in group installationsFusesCircuit breaker480 V600 V480 V600 V480 V600 V480Y / 277 V 600Y / 347 VAAkAkAkAkAkAkAkAkAMS132-0.16Any Listed fuses. Size per NEC/CECAny Listed UL489 / CSA C22.2 No.5 circuit breaker. Size per NEC/CEC6547654765476547MS132-0.256547654765476547MS132-0.406547654765476547MS132-0.636547654765476547MS132-1.06547654765476547MS132-1.66547654765476547MS132-2.56547654765476547MS132-4.06547654765476547MS132-6.36518653565186518MS132-106518653565186518MS132-1230183535301830-MS132-1630183535301830-MS132-2030183535301830-MS132-2530183535301830-MS132-3230183535301830-(1) NEC: NFPA®70 National Electrical Code®; CEC: CSA C22.1 Canadian Electrical Code.(2) Requires the use of S1-M3-xx line-side terminal feeder block.—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C02012/22ABB MOTOR PROTECTION AND CONTROLUL/CSA Maximum short-circuit current ratings – MS132 with AF contactorsTy peCombination Motor Controllers (Type F) (1)Coordination type 1 Minimum contactor size480Y / 277 V600Y / 347 VkAkAMS132-0.16AF09 ... AF3810050MS132-0.25AF09 ... AF3810050MS132-0.40AF09 ... AF3810050MS132-0.63AF09 ... AF3810050MS132-1.0AF09 ... AF3810050MS132-1.6AF09 ... AF3810050MS132-2.5AF09 ... AF3810050MS132-4.0AF09 ... AF3810050MS132-6.3AF09 ... AF3810047MS132-10AF09 ... AF3810030MS132-12AF09 ... AF386530MS132-16AF12 ... AF386530MS132-20AF26 ... AF3865–MS132-25AF26 ... AF3850–MS132-32AF3850–Coordination type 2 MS132-0.16AF26 ... AF386547MS132-0.25AF26 ... AF386547MS132-0.40AF26 ... AF386547MS132-0.63AF26 ... AF386547MS132-1.0AF26 ... AF386547MS132-1.6AF26 ... AF386547MS132-2.5AF26 ... AF386547MS132-4.0AF26 ... AF386547MS132-6.3AF26 ... AF386547MS132-10AF26 ... AF386547MS132-12AF26 ... AF3830-MS132-16AF26 ... AF3830-MS132-20AF26 ... AF3830-MS132-25AF26 ... AF3830-MS132-32AF26 ... AF3830-UL/CSA Maximum short-circuit current ratings – MO132 with electronic overload relays and AF contactorsTy peEOLCombination Motor Controllers(Type F) (1)Coordination type 1 Minimum contactor size480Y / 277 V600Y / 347 VkAkAMO132-0.16EF19AF09 ... AF3810050MO132-0.25EF19AF09 ... AF3810050MO132-0.40EF19AF09 ... AF3810050MO132-0.63EF19AF09 ... AF3810050MO132-1.0EF19AF09 ... AF3810050MO132-1.6EF19AF09 ... AF3810050MO132-2.5EF19AF09 ... AF3810050MO132-4.0EF19AF09 ... AF3810050MO132-6.3EF19AF09 ... AF3810050MO132-10EF19AF09 ... AF3810030MO132-12EF19AF09 ... AF386530MO132-16EF19AF12 ... AF386530MO132-20EF19AF16 ... AF3865–MO132-25EF45-30AF26 ... AF3850–MO132-32EF45-45AF38 ... AF3850–NOTE : More coordination tables are available in our SOC (selected optimized coordination) tool: https://applications.it.abb.com/SOC/Motor.(1) Requires the use of S1-M3-xx line-side terminal feeder block.—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C0201ABB MOTOR PROTECTION AND CONTROL 2/23UL/CSA Maximum short-circuit current ratings – MS165Ty peManual Motor ControllersManual self-protected Combination Motor Controllers (Type E)Branch circuit protection, max. size per NEC/CEC (1)for motor disconnectfor group installationsfor tap conductor protection in group installationsFusesCircuit breaker480 V600 V480 V600 V480 V600 V480Y / 277 V 600Y / 347 VAAkAkAkAkAkAkAkAkAMS165-16Any Listed fuses. Size per NEC/CECAny Listed UL489 / CSA C22.2 No.5 circuit breaker. Size per NEC/CEC6530653065306530MS165-206530653065306530MS165-256530653065306530MS165-326530653065306530MS165-426530653065306530MS165-546530653065306530MS165-656530653065306530MS165-7350105010MS165-8050105010(1) NEC: NFPA®70 National Electrical Code®; CEC: CSA C22.1 Canadian Electrical Code.UL/CSA Maximum short-circuit current ratings – MS165 with AF contactorsTy peManual self-protected Combination Motor Controllers(Type F)Manual self-protected Combination Motor Controllers(Type F)Coordination type 1Coordination type 2Minimum contactor size480Y /Minimum contactor size600Y /Minimum contactor size480Y /Minimum contactor size600Y /277 V347 V277 V347 VkAkAkAkAMS165-16AF09...AF3865AF09...AF3850AF26...AF3865AF09...AF3830MS165-20AF26...AF3865AF26...AF3850AF26...AF3865AF09...AF3830MS165-25AF26...AF3865AF26...AF3850AF26...AF3865AF40...AF6530MS165-32AF26...AF3865AF26...AF3850AF26...AF3865AF40...AF6530MS165-42AF40...AF6565AF40...AF6530AF40...AF6565AF40...AF6530MS165-54AF40...AF6565AF40...AF6530AF40...AF6565AF40...AF6530MS165-65AF40...AF6565AF40...AF6530AF40...AF6565AF40...AF6530MS165-73MS165-80More coordination tables are available in our SOC (selected optimized coordination) tool:https://applications.it.abb.com/SOC/MotorUL/CSA Maximum short-circuit current ratings – MO132Ty peManual Motor ControllersBranch circuit protection, max. size per NEC/CEC (1)for motor disconnectfor group installationsfor tap conductor protection in group installationsFusesCircuit breaker480 V600 V480 V600 V480 V600 VAAkAkAkAkAkAkAMO132-0.16Any Listed fuses. Size per NEC/CECAny Listed UL489 / CSA C22.2 No.5 circuit breaker. Size per NEC/CEC654765476547MO132-0.25654765476547MO132-0.40654765476547MO132-0.63654765476547MO132-1.0654765476547MO132-1.6654765476547MO132-2.5654765476547MO132-4.0654765476547MO132-6.3651865356518MO132-10651865356518MO132-12301835353018MO132-16301835353018MO132-20301835353018MO132-25301835353018MO132-32301835353018(1) NEC: NFPA®70 National Electrical Code®; CEC: CSA C22.1 Canadian Electrical Code.—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C02012/24ABB MOTOR PROTECTION AND CONTROLUL/CSA Maximum short-circuit current ratings – MO165Ty peManual Motor ControllersBranch circuit protection, max. size per NEC/CEC (1)for motor disconnectfor group installationsfor tap conductor protection in group installationsFusesCircuit breaker480 V600 V480 V600 V480 V600 VAAkAkAkAkAkAkAMO165-16Any Listed fuses. Size per NEC/CECAny Listed UL489 / CSA C22.2 No.5 circuit breaker. Size per NEC/CEC653065306530MO165-20653065306530MO165-25653065306530MO165-32653065306530MO165-42653065306530MO165-54653065306530MO165-65653065306530MO165-7350105010MO165-8050105010(1) NEC: NFPA®70 National Electrical Code®; CEC: CSA C22.1 Canadian Electrical Code.UL/CSA Maximum short-circuit current ratings – MO165 with AF contactorsTy peCombination Motor Controllers (Type F)Coordination type 1480Y / 277 VOL RelayContactor600Y / 347 VOL RelayContactorkAkAMO165-1665EF19-18.9AF09...AF3850EF19-18.9AF09...AF38MO165-2065EF45-30AF26...AF3850EF45-30AF26...AF38MO165-2565EF45-30AF26...AF3850EF45-30AF26...AF38MO165-3265EF45-45AF26...AF3850EF45-45AF26...AF38MO165-4265EF65AF40...AF6530EF65AF40...AF65MO165-5465EF65AF40...AF6530EF65AF40...AF65MO165-6565EF65AF40...AF6530EF65AF40...AF65MO165-73MO165-80UL/CSA Maximum short-circuit current ratings – MO165 with AF contactorsTy peCombination Motor Controllers (Type F)Coordination type 2480Y / 277 VOL RelayContactor600Y / 347 VOL RelayContactorkAkAMO165-1665TF42AF09...AF3830TF42AF09...AF38MO165-2065TF42AF26...AF3830TF42AF09...AF38MO165-2565TF42AF26...AF3850TF42AF26...AF38MO165-3265TF42AF26...AF3850TF42AF26...AF38MO165-4265TF65AF40...AF6530TF65AF40...AF65MO165-5465TF65AF40...AF6530TF65AF40...AF65MO165-6565TF65AF40...AF6530TF65AF40...AF65MO165-73MO165-80—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C0201ABB MOTOR PROTECTION AND CONTROL 2/25General technical dataTy peMS116MS132MS165MO132MO165Pollution degree33333Phase loss sensitivityYesYesYesNoNoDisconnect function acc. to IEC/EN 60947-2YesYesYesYesYesAmbient air temperatureOperationOpen - compensated -25 ... +55 °C-25 ... +60 °C-25 ... +60 °C--Open-25 ... +70 °C-25 ... +70 °C-25 ... +60 °C-25 ... +60 °C-25 ... +60 °CEnclosed (IB132) 0 ... +40 °C0 ... +40 °C---Storage-50 ... +80 °C-50 ... +80 °C-50 ... +80 °C-50 ... +80 °C-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Acc. to IEC/EN60947-4-1Acc. to IEC/EN60947-4-1--Maximum operating altitude permissible2000 m2000 m2000 m2000 m2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 ms25g / 11 ms25g / 11 ms25g / 11 ms25g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz5g / 3 ... 150 Hz5g / 3 ... 150 Hz5g / 3 ... 150 Hz5g / 3 ... 150 HzMounting positionPosition 1-6 (optional for single mounting)Position 1-6 (optional for single mounting)Position 1-6 (optional for single mounting)Position 1-6 (optional for single mounting)Position 1-6 (optional for single mounting)MountingDIN-rail (EN 60715)DIN-rail (EN 60715)DIN-rail (EN 60715)DIN-rail (EN 60715)DIN-rail (EN 60715)Group mountingOn requestOn requestOn requestOn requestOn requestRecommended screw for mounting plate--M4-M4Screw torque for mounting plate--2 Nm-2 NmMinimum distance to other units same typeHorizontal0 mm0 mm0 mm0 mm0 mmVertical150 mm150 mm150 mm150 mm150 mmMinimum distance to electrical conductive boardHorizontal, up to 400 V 0 mm0 mm0 mm0 mm0 mmHorizontal, up to 690 V > 1.5 mm> 1.5 mm> 1.5 mm> 1.5 mm> 1.5 mmVertical75 mm75 mm75 mm75 mm75 mmDegree of protectionHousingIP20IP20IP20IP20IP20Main circuit terminalsIP10IP10 (1)IP10IP10IP10(1) Push-in Spring terminals : IP20Connecting characteristics - Main circuitTy peMS116 ≤ 16 AMS116 ≥ 20 AConnecting capacityRigid 1 or 2 x 1 ... 4 mm²2.5 ... 6 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²1 ... 6 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²1 ... 6 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²1 ... 6 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-12AWG 16-8Stripping length9 mm10 mmTightening torque0.8 ... 1.2 Nm / 10 ... 12 Ib.in 2.0 Nm / 18 Ib.inRecommended screwdriverPozidriv 2Pozidriv 2Ty peMS132 ≤ 10 AMS132 ≥ 12 AConnecting capacityRigid 1 or 2 x 1 ... 4 mm²1 ... 2.5 mm²2.5 ... 6 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²1 ... 2.5 mm²2.5 ... 6 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-12AWG 16-8Stripping length9 mm10 mmTightening torque0.8 ... 1.2 Nm / 10 ... 12 Ib.in 2.0 Nm / 18 Ib.inRecommended screwdriverPozidriv 2Pozidriv 2Ty peMS132-K with Push-in Spring terminalsConnecting capacityRigid solid 1 or 2 x 1 ... 2.5 mm²Rigid stranded1 or 2 x 1 ... 6 mm²Flexible with ferrule1 or 2 x 0.5 ... 4 mm²Flexible with insulated ferrule1 x 0.5 ... 4 mm²1/2 x 0.5 ... 2.5 mm²Flexible1 or 2 x 0.75 ... 4 mm²Stranded acc. to UL/CSA1/2 x AWG 18 ... AWG 101 x AWG 8Wire stripping length12 mmScrewdriverFlat Ø 3 mm x 0.5 mm—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C02012/26ABB MOTOR PROTECTION AND CONTROLConnecting characteristics - Main circuitTy peMS165Connecting capacityRigid stranded 1 or 2 x 1 ... 50 mm²Flexible with ferrule1 or 2 x 1 ... 35 mm²Flexible with insulated ferrule1 or 2 x 1 ... 35 mm²Flexible1 or 2 x 1 ... 35 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-0Stripping length16 mmTightening torque4.0 Nm / 35 Ib.inRecommended screw driverPozidriv 2Ty peMO132 ≤ 10 AMO132 ≥ 12 AConnecting capacityRigid 1 or 2 x 1 ... 4 mm²1 ... 2.5 mm²2.5 ... 6 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²1 ... 2.5 mm²2.5 ... 6 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-12AWG 16-8Stripping length9 mm10 mmTightening torque0.8 ... 1.2 Nm / 10 ... 12 Ib.in 2.0 Nm / 18 Ib.inRecommended screw driverPozidriv 2Pozidriv 2Ty peMO165Connecting capacityRigid stranded1 or 2 x 1 ... 50 mm²Flexible with ferrule1 or 2 x 1 ... 35 mm²Flexible with insulated ferrule1 or 2 x 1 ... 35 mm²Flexible1 or 2 x 1 ... 35 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-0Stripping length16 mmTightening torque4.0 Nm / 35 Ib.inRecommended screw driverPozidriv 2—MS116, MS132, MS165, MO132, MO165 Technical data02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/2702
2CDC131062C02012/28ABB MOTOR PROTECTION AND CONTROL—Circuit breakers for transformer protectionTroubleshooting made easy MS132-T feature a magnetic trip indicator. This way, every tripping event will be distinguished, making troubleshooting a lot easier and faster.Transformer protection MS132-T is an inrush compensated circuit breaker for control transformer protec-tion. With the right selection, it provides overcurrent protection on the primary side of the transformer. This avoids expensive protection on the secondary side.Complete portfolioManual motor starter accessories are suitable throughout the complete range. Moreover ABB offers special accessories for fast single-phase setup.Low voltage transformers are used to supply power to control and auxiliary circuits in distribution and automation boards and to provide galvanic isolation. These transformers may be damaged by an electrical failure (short-circuit or overload on the primary side), therefore a proper protection should be provided.Circuit breakers for transformers protection are specially designed for fuseless protection of control transformers on the primary side against overloads and short-circuits. Application exampleProtection of transformers for power supply of control and auxiliary circuits, both in distribution and automation boards (checking, signaling, interlock, etc).S1-PB1-25PB1-1-3202
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/29—MS132-T circuit breakers for transformer protection0.10 to 25 A – with thermal and electromagnetic protectionCircuit breakers for transformer protection are electro-mechanical protection devices specially designed to protect control transformers on the primary side. They allow fuseless protection against overload and short-circuit, saving space and cost and ensuring a quick reaction under short-circuit condition by switching off the transformer within milliseconds. The short-circuit current setting is fixed to 20 times the operating current to handle the high inrush current gen-erated by transformers. The device allows manual connection and disconnection of the transformer from the mains. MS132-T is a 45 mm (width) compact and powerful range for transformer protection up to 12.5 kW (400 V) / 25 A. This type has also a clear and reliable indication of fault in a separate win-dow in the event of short-circuit tripping. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch posi-tion indication. The handle is lockable to protect against unauthorized changes. Auxiliary con-tacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165-range. Moreover ABB offers special accessories for fast single phase setup.Setting rangeShort-circuit breaking capacity Icsat 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)AkAAkg0.10 ... 0.161003.2MS132-0.16T1SAM340000R10010.2150.16 ... 0.251005MS132-0.25T1SAM340000R10020.2150.25 ... 0.401008MS132-0.4T1SAM340000R10030.2150.40 ... 0.6310012.6MS132-0.63T1SAM340000R10040.2150.63 ... 1.0010020MS132-1.0T1SAM340000R10050.2151.00 ... 1.6010032MS132-1.6T1SAM340000R10060.2651.60 ... 2.5010050MS132-2.5T1SAM340000R10070.2652.50 ... 4.0010080MS132-4.0T1SAM340000R10080.2654.00 ... 6.30100126MS132-6.3T1SAM340000R10090.2656.30 ... 10.0100200MS132-10T1SAM340000R10100.2658.00 ... 12.0100240MS132-12T1SAM340000R10120.31010.0 ... 16.0100320MS132-16T1SAM340000R10110.31016.0 ... 20.0100400MS132-20T1SAM340000R10130.31020.0 ... 25.050500MS132-25T1SAM340000R10140.310MS132-10T2CDC241002F0014MS132-25T 1.38" 0.1" 3.54" 2.95" 0.22" 0.06" 0.55" 1.77" 0.55" 2.85" 3.2" 1.71" 1.77" 35 1.7 90 755.51.5 14 45 14 72.4 81.25 43.5 45" 0.06"0.22"0.22"2.84" 3.19"0.1"3.85"1.77" 0.55" 0.55" 1.77" 2.95"1.38"1.5 5.5 43.3 72.2 81.05 1.797.8 45 14 14 45 75 35MS132T ≤ 10 AMS132T ≥ 12 AMain dimensions mm, inches2CDC241009V001702
2CDC131062C02012/30ABB MOTOR PROTECTION AND CONTROL—MS132-KT circuit breakers for transformer protection with Push-in Spring terminals0.10 to 25 A – with thermal and electromagnetic protectionCircuit breakers for transformer protection with Push-in Spring terminals are electro-mechanical protection devices specially designed to protect control transformers on the primary side. They al-low fuseless protection against overload and short-circuit, saving space and cost and ensuring a quick reaction under short-circuit condition by switching off the transformer within milliseconds. The short-circuit current setting is fixed to 20 times the operating current to handle the high inrush current generated by transformers. The device allows manual connection and disconnection of the transformer from the mains. MS132-KT is a 45 mm (width) compact and powerful range for transformer protection up to 12.5 kW (400 V) / 25 A. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the built-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases and shunt trips are available as accessory. These are suitable throughout the MS116/MS132/MS165-range. Setting rangeShort-circuit breaking capacity Icsat 400 V ACRated instantaneous short-circuit current setting liTy pe Order codeWeight(1 pce)AkAAkg0.10 ... 0.161003.2MS132-0.16KT1SAM340010R10010.2560.16 ... 0.251005MS132-0.25KT1SAM340010R10020.2560.25 ... 0.401008MS132-0.4KT1SAM340010R10030.2560.40 ... 0.6310012.6MS132-0.63KT1SAM340010R10040.2560.63 ... 1.0010020MS132-1.0KT1SAM340010R10050.2561.00 ... 1.6010032MS132-1.6KT1SAM340010R10060.2981.60 ... 2.5010050MS132-2.5KT1SAM340010R10070.2802.50 ... 4.0010080MS132-4.0KT1SAM340010R10080.2864.00 ... 6.30100126MS132-6.3KT1SAM340010R10090.2896.30 ... 10.0100200MS132-10KT1SAM340010R10100.29610.0 ... 16.0100320MS132-16KT1SAM340010R10110.31616.0 ... 20.0100400MS132-20KT1SAM340010R10130.31720.0 ... 25.050500MS132-25KT1SAM340010R10140.316MS132-KT81 3.19"72.5 2.85"43.5 1.71"5.5 0.22"45 1.77"90 3.54"45 1.77"112 4.41"35mm EN/EC 6071581 3.19"72.5 2.85"43.5 1.71"5.5 0.22"45 1.77"90 3.54"45 1.77"112 4.41"35mm EN/EC 60715MS132-KT > 10 AMS132-KT < 10 AMain dimensions mm, inches02
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/31—MS132-T, MS132-KT Technical dataMain circuit – Utilization characteristics according to IEC/ENTy peMS132-T / -KTStandardsIEC/EN 60947–2, IEC/EN 60947-4-1, IEC/EN 60947-1Rated operational voltage Ue690 V ACRated frequency50/60 HzOperational frequency0 ... 400 HzTrip class10Number of poles3Duty time100%Mechanical durability100000 cyclesElectrical durability50000 cyclesRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VRated operational current IeSee ordering detailsRated instantaneous short-circuit current setting IiSee ordering detailsRated service short-circuit breaking capacity IcsSee table "Short-circuit breaking capacity and back-up fuses"Rated ultimate short-circuit breaking capacity IcuSee table "Short-circuit breaking capacity and back-up fuses"Short-circuit breaking capacity and back-up fuseslcsRated service short-circuit breaking capacitylcuRated ultimate short-circuit breaking capacityIccProspective short-circuit current at installation locationNote: Maximum rated current of the back-up fuses if Icc > IcsTy pe230 V AC 400 V AC440 V AC500 V AC690 V ACIcs IcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMIcsIcugG, aMkAkAAkAkAAkAkAAkAkAAkAkAAMS132-0.16T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.25T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.4T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-0.63T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-1.0T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-1.6T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-2.5T / -KT100100- (1)100100- (1)100100- (1)100100- (1)100100- (1)MS132-4.0T / -KT100100- (1)100100- (1)303035 (2)202035 (2)3335 (2)MS132-6.3T / -KT100100- (1)100100- (1)303063 (2)202063 (2)3350 (2)MS132-10T / -KT100100- (1)100100- (1)3030100 (2)2020100 (2) 3350 (2)MS132-12T100100- (1)100100- (1)3030100 (2)2020100 (2) 3363 (2)MS132-16T / -KT100100- (1)100100- (1)3030125 (2)2020125 (2) 3363 (2)MS132-20T / -KT100100- (1)100100- (1)3030125 (2)2020125 (2) 3380 (2)MS132-25T / -KT5050125 (2)5050125 (2)3030125 (2)1010125 (2) 33100 ( 2)(1) No back-up fuse required, because short-circuit proof up to 100 k A(2) Rated back-up fuse for short-circuits up to 100 k A02
2CDC131062C02012/32ABB MOTOR PROTECTION AND CONTROL—MS132-T, MS132-KT Technical dataMain circuit – Utilization characteristics according to ULTy peMS132-T / -KTStandardsUL 60947-1, UL 60947-4-1Rated operational voltage Ue acc. to UL/CSA600 V ACTrip class10Motor ratings (1)Full Load Amps (FLAsee table UL current ratings(1) See product data sheets for UL/CSA single phase motor and general use (AC-1) ratings.UL/CSA ratings overviewTy peMS132-T / -KTManual Motor Controllernot applicableManual Motor Controller, Suitable as Motor Disconnectnot applicableManual Motor Controller, Suitable for use in Group Installationsnot applicableManual Motor Controller, Suitable for Tap Conductor Protection in Group InstallationsxManual self-protected Combination Motor Controller (Type E)not applicableCombination Motor Controller (Type F)not applicableUL current ratings, single-phase – MS132-T / -KTTy pe120 V AC220 ... 240 V ACFLAFLAMS132-0.16T / -KT0.160.16 MS132-0.25T / -KT0.250.25 MS132-0.4T / -KT0.40.4 MS132-0.63T / -KT0.630.63 MS132-1.0T / -KT11 MS132-1.6T / -KT1.61.6 MS132-2.5T / -KT2.52.5 MS132-4.0T / -KT44 MS132-6.3T / -KT6.36.3 MS132-10T / -KT9.810 MS132-12T9.812 MS132-16T / -KT1612 MS132-20T / -KT2017 MS132-25T / -KT2417 UL 508 — Manual controller for tap conductor protection and for control transformersTy peMax. short-circuit current rating when used with upstream protection device480 V600 VkAkAMS132-0.16T / -KT6547MS132-0.25T / -KT6547MS132-0.4T / -KT6547MS132-0.63T / -KT6547MS132-1.0T / -KT6547MS132-1.6T / -KT6547MS132-2.5T / -KT6547MS132-4.0T / -KT6547MS132-6.3T / -KT6518MS132-10T / -KT6518MS132-12T3018MS132-16T / -KT3018MS132-20T / -KT3018MS132-25T / -KT301802
2CDC131062C0201 ABB MOTOR PROTECTION AND CONTROL 2/33—MS132-T, MS132-KT Technical dataGeneral technical dataTy peMS132-T / - KTPollution degree3Phase loss sensitivityYesDisconnect function acc. to IEC/EN 60947-2YesAmbient air temperatureOperationOpen - compensated-25 ... +60 °COpen-25 ... +70 °CEnclosed (IB132)0 ... +40 °CStorage-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzMounting positionPosition 1-6 (optional for single mounting)MountingDIN-rail (EN 60715)Group mounting-Recommended screw for mounting plate-Screw torque for mounting plate-Minimum distance to other units same typeHorizontal0 mmVertical150 mmMinimum distance to electrical conductive boardHorizontal, up to 400 V0 mmHorizontal, up to 690 V> 1.5 mmVertical75 mmDegree of protectionHousingIP20Main circuit terminalsIP10 (Push-in Spring terminals: IP20)Connecting characteristics - main circuitTy peMS132-T ≤ 10 AMS132-T ≥ 12 AConnecting capacityRigid 1 or 2 x 1 ... 4 mm²1 ... 2.5 mm²2.5 ... 6 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 6 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²1 ... 2.5 mm²2.5 ... 6 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-12AWG 16-8Stripping length9 mm10 mmTightening torque0.8 ... 1.2 Nm / 10 ... 12 Ib.in 2.0 Nm / 18 Ib.inRecommended screwdriverPozidriv 2Pozidriv 2Connecting characteristics - main circuitTy peMS132-KT with Push-in Spring terminalsConnecting capacityRigid solid1 or 2 x 1 ... 2.5 mm²Rigid stranded1 or 2 x 1 ... 6 mm²Flexible with ferrule1 or 2 x 0.5 ... 4 mm²Flexible with insulated ferrule1 x 0.5 ... 4 mm²1/2 x 0.75 ... 4 mm²Flexible1 or 2 x 0.75 ... 4 mm²Stranded acc. to UL/CSA1/2 x AWG 18 ... AWG 10Wire stripping length12 mmTightening torque0.8 ... 1.2 Nm / 10 ... 12 Ib.in ScrewdriverFlat Ø 3 mm x 0.5 mm02
2CDC131050C02012/34ABB MOTOR PROTECTION AND CONTROL—AccessoriesMS116, MS132, MS165, MO132, MO165, MS132-TManual motor starters with accessories (MS116, MO132, MO165)Manual motor starters (MS132, MS165) and circuit breakers for transformer protection (MS132-T) with accessoriesHK1HK1HK1SK1MS116MO132MO165UA1AA1HK1HK1SK1SK1MS132MS132-TMS165MS132-KMS132-KTUA1AA1HK1CK1CK1HK1HKF1HKF1Note: The combination of MS132-K + UA1 + CK1 is not possible02
2CDC131050C0201 ABB MOTOR PROTECTION AND CONTROL 2/35—AccessoriesMS116, MS132, MS165, MO132, MO165, MS132-T, MS132-K, MS132-KTManual motor starters and MS132-T can be equipped with auxiliary contacts for lateral/front mounting, signaling contacts for lateral mounting, undervoltage releases and shunt trips. Two different signaling contacts are available. The accessories can be fitted wiring free and without tools. A variety of combinations is possible as required for the application. The auxiliary contacts change position with the main contacts. The signaling contact SK1 signals tripping regardless if it was caused by short-circuit or overload. The signaling contact CK1 signals tripping in case it was caused by short-circuit. Undervoltage releases are used for remote tripping of the manual motor starters, specially for emergency stop circuits. Shunt trips release the manual motor starters used for remote tripping. These main accessories are suitable throughout the MS116/MS132/MS165-range.Suitable forAuxiliary contacts N.O.Auxiliary contacts N.C.DescriptionTy pe Order codePkgqtyWeight (1 pce)kgAuxiliary contacts – mountable on the frontMS116, MS132, MS165, MO132, MO165, MS132-T,MS132-K, MS132-KT11HKF1-111SAM201901R1001100.01510HKF1-101SAM201901R1003100.01301HKF1-011SAM201901R1004100.01320HKF1-201SAM201901R1002100.015Auxiliary contacts – mountable on the rightMS116, MS132, MS165, MO132, MO165, MS132-T, MS132-K, MS132-KT11max. 2 piecesHK1-111SAM201902R100120.03520max. 2 piecesHK1-201SAM201902R100220.03502max. 2 piecesHK1-021SAM201902R100320.035MS116, MS132, MO132, MS132-T, MS132-K, MS132-KT20max. 2 pieceswith leading contactsHK1-20L1SAM201902R100420.035Signaling contacts – mountable on the rightMS116, MS132, MS165, MO132, MO165, MS132-T, MS132-K, MS132-KT11for tripped alarmSK1-111SAM201903R100120.03520for tripped alarmSK1-201SAM201903R100220.03502for tripped alarmSK1-021SAM201903R100320.035MS132, MS165, MS132-T, MS132-K, MS132-KT11for short-circuit alarmCK1-111SAM301901R100120.03520for short-circuit alarmCK1-201SAM301901R100220.03502for short-circuit alarmCK1-021SAM301901R100320.035HKF1-11 1SBC101209F0014HK1-11 1SBC101210F0014SK1-111SBC101286F0014CK1-115.5 42.327.868.89 90 72 45 42.1 3.54"0.22"2.83"1.77"1.67"1.09"2.71"1.66"0.35"HK1Main dimensions mm, inches1SBC101208F001402
2CDC131050C02012/36ABB MOTOR PROTECTION AND CONTROL—AccessoriesMS116, MS132, MS165, MO132, MO165, MS132-TSuitable forRated control supply voltageTy pe Order codePkgqtyWeight (1 pce)50 HzV AC60 HzV ACkgShunt trips – mountable on the leftMS116, MS132, MS165, MO132, MO165, MS132-T20 ... 2420 ... 24AA1-241SAM201910R100110.100110110AA1-1101SAM201910R100210.100200 ... 240200 ... 240AA1-2301SAM201910R100310.100350 ... 415350 ... 415AA1-4001SAM201910R100410.100Undervoltage releases – mountable on the leftMS116, MS132, MS165, MO132, MO165, MS132-T2024UA1-201SAM201904R101010.10024-UA1-241SAM201904R100110.10048-UA1-481SAM201904R100210.10060-UA1-601SAM201904R100310.100110120UA1-1101SAM201904R100410.100-208UA1-2081SAM201904R100810.100230240UA1-2301SAM201904R100510.100400-UA1-4001SAM201904R100610.100415480UA1-4151SAM201904R100710.100-575UA1-5751SAM201904R100910.100 1SBC101211F0014AA1-24 1SBC101212F0014UA1-2490 45 5.5 43.57037 183.54"1.77"1.71"2.76"0.22"1.46"0.71"A A1, UA1 Main dimensions mm, inches02
2CDC131050C0201 ABB MOTOR PROTECTION AND CONTROL 2/37—AccessoriesWith Push-in Spring terminalsManual motor starters can be equipped with auxiliary contacts for lateral and front mounting as well as signaling contacts for lateral mounting. The accessories are equipped with Push-in Spring terminals that enable tool-free wiring. A variety of combinations is possible as required for the application. The auxiliary contacts change position with the main contacts. The signaling contact SK1 signals tripping regardless if it was caused by short-circuit or overload. These main accessories are suitable throughout the MS116/MS132/MS165-range.Suitable forAuxiliary contacts N.O.Auxiliary contactsN.C.DescriptionTy peOrder codePkg qtyWeight (1 pce)kgAuxiliary contacts - mountable on the frontMS116, MS132, MS165 MO132, MO165, MS132-T,MS132-K, MS132-KT11HKF1-11K1SAM201901R1201100.01620HKF1-20K1SAM201901R1202100.016Auxiliary contacts - mountable on the rightMS116, MS132, MS165 MO132, MO165, MS132-T,MS132-K, MS132-KT11max. 2 piecesHK1-11K1SAM201902R120120.03520max. 2 piecesHK1-20K1SAM201902R120220.03502max. 2 piecesHK1-02K1SAM201902R120320.03520with leading contactsHK1-20LK1SAM201902R120420.035Signaling contacts - mountable on the rightMS116, MS132, MS165 MO132, MO165, MS132-T,MS132-K, MS132-KT11for tripped alarmSK1-11K1SAM201903R120120.03520for tripped alarmSK1-20K1SAM201903R120220.03502for tripped alarmSK1-02K1SAM201903R120320.03542.3 1.67"68.8 2.71"73.1 2.9"9 0.35"5.5 0.22"90 3.54"45 1.77"SK1-K451.77"12.5 0.49"27.2 1.07"HKF1-K42.3 1.67"68.8 2.71"9 0.35"5.5 0.22"90 3.54"45 1.77"HK1-KMain dimensions mm, inches2CDC241028V00172CDC241027V00172CDC241029V0017SK1-11KHKF1-11KHK1-11K02
2CDC131050C02012/38ABB MOTOR PROTECTION AND CONTROLGeneral technical dataTy peHK1, SK1CK1HKF1StandardsIEC/EN 60947–1, IEC/EN 60947-5-1Rated operational voltage Ue690 V AC / 600 V DC250 V AC / 250 V DCConventional free-air thermal current Ith6 A5 ARated frequency50/60 HzRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V AC250 V ACPollution degree3Ambient air temperatureOperation-25 ... +60 °CStorage-50 ... +80 °CResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzIe / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category24 V, 120 V 6 A3 A240 V 4 A1.5 A400 V 3 A-440 V, 690 V 1 A-Ie / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 V 2 A1 A125 V 0.55 A0.27 A250 V 0.27 A0.11 A440 V, 600 V 0.15 A-Minimum switching capacity17 V / 5 mAShort-circuit protective deviceN.C., 95-96 10 A Type gGN.O., 97-98 10 A Type gGDuty time100 % MountingRight side of MMS / MS132-TFront of MMS / MS132-TMounting positions1-6Mechanical durability100000 cycles 10000 cycles-Electrical durability100000 cycles 10000 cycles-Contact utilization characteristics according to UL/CSATy peHK1, SK1, CK1HKF1StandardsUL 60947-1, UL 60947-5-1 (UL 508), CSA C22.2 No.60947-5-1 (CSA C22.2 No.14)Rated operational voltage Ue acc. to UL/CSA600 V AC / 600 V DC250 V AC / 250 V DCPilot dutyB600, Q600B300, R300AC thermal rated current5 A5 AAC maximum volt-ampere making3600 VA3600 VAAC maximum volt-ampere breaking360 VA360 VADC thermal rated current2.5 A1 ADC maximum volt-ampere making-breaking69 VA28 VAConnecting characteristics - Auxiliary circuitTy peHK1, SK1, CK1HKF1Connecting capacityRigid 1 or 2 x 1 ... 1.5 mm² 1 ... 2.5 mm² 0.5 ... 2.5 mm² (with Push-in Spring terminals)Flexible with ferrule1 or 2 x 0.75 ... 1.5 mm²0.5 ... 2.5 mm² (with Push-in Spring terminals)Flexible with insulated ferrule1 or 2 x 0.75 ... 1.5 mm²0.5 ... 1.5 mm² (with Push-in Spring terminals)Flexible1 or 2 x 0.75 ... 1.5 mm²0.5 ... 2.5 mm² (with Push-in Spring terminals)Stranded acc. to UL/CSA1 or 2 x AWG 16-14AWG 20 - 14 (with Push-in Spring terminals)Stripping length8 mm10 mm (with Push-in Spring terminals)Tightening torque0.8 ... 1.2 Nm / 7 Ib.in Recommended screw driverPozidriv 2Flat Ø 3 mm x 0.5 mm (with Push-in Spring terminals)—AccessoriesMS116, MS132, MS165, MO132, MO165, MS132-T02
2CDC131050C0201 ABB MOTOR PROTECTION AND CONTROL 2/39General technical dataTy peUA1AA1StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1 (UL 508), CSA C22.2 No.60947-4-1 (CSA C22.2 No.14)Rated control supply voltagesee ordering detailsAA1-24: 20-24 V 50/60 Hz; 20-70 V 50/60 Hz ON-Period = 5 s, 20-70 V DC ON-Period = 5 sAA1-100: 110 V 50/60 Hz; 110-200 V 50/60 Hz ON-Period = 5 s, 110-200 V DC ON-Period = 5 sAA1-230: 200-240 V 50/60 Hz, 200-350 V 50/60 Hz ON-Period = 5 s, 200-350 V DC ON-Period = 5 sAA1-400: 350-415 V 50/60 Hz, 350-500 V 50/60 Hz ON-Period = 5 s, 350-500 V DC ON-Period = 5 sRated frequencysee ordering details50/60 Hz, DCOperating voltageTripping0.35 ... 0.7 x Us0.7 ... 1.1 x UsCoil operating voltage0.85 ... 1.1 x Us-Power consumptionPull-inACon requeston requestDCon requeston requestHoldingACon request-DCon request-Rated impulse withstand voltage Uimp6 kV6 kVRated insulation voltage Ui690 V690 VPollution degree33Ambient air temperatureOperation-25 .... +60 °C-25 .... +60 °CStorage-50 ...+80 °C-50 ...+80 °CResistance to shock acc. to IEC 60068-2-2715g / 11 ms15g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz5g / 3 ... 150 HzMountingleft side of MMS / MS132-Tleft side of MMS / MS132-TMounting positions--ON-Period: max. 5s actuation timeConnecting characteristics - Auxiliary circuitTy peUA1AA1Connecting capacityRigid 1 or 2 x 1 ... 4 mm² Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x2 x0.75 ... 2.5 mm²0.75 ... 1.5 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-12Stripping length10 mmTightening torque0.8 ... 1.2 Nm / 7 Ib.in Recommended screwdriverPozidriv 2—AccessoriesMS116, MS132, MS165, MO132, MO165, MS132-T02
2CDC131050C02012/4 0ABB MOTOR PROTECTION AND CONTROL—AccessoriesMS116, MS132, MS165, MO132, MO165Manual motor starters with three-phase busbar systems (MS116, MS132, MO132)Note: busbars and feeder blocks are only suitable for screw versions.Manual motor starters with three-phase busbar systems (MS165, MO165)SA1PS1-..-65PS1-..-100BS1-3S1-M2-25S1-M3-35S1-M1-25PS2-4-0-125PS2-2-0-125PS2-4-0-125BS2-3BS2-3Three-phase busbar up to 65 AThree-phase busbar up to 100 AThree-phase busbar up to 125 AThree-phase busbar up to 125 A02
2CDC131050C0201 ABB MOTOR PROTECTION AND CONTROL 2/41Three-phase busbars ensure a quick and safe connection and are therefore a cost effective solution. A variety of different three-phase busbars up to 100 A are in the assortment. Between 2 and 4 manual motor starters with none, one or two lateral auxiliary contacts can be connected. Different three-phase feeder terminals are available according to the application.Phase connecting links and phase power infeed blocks are also available for single-phase applications.Suitable forRated operational currentNumber of manual motor startersNumber of lateral auxiliary contactsTy pe Order codePkgqtyWeight (1 pce)AkgThree-phase busbarsMS116, MS132, MO1326520PS1-2-0-651SAM201906R1102100.0346530PS1-3-0-651SAM201906R1103100.0556540PS1-4-0-651SAM201906R1104100.0776550PS1-5-0-651SAM201906R1105100.0986521PS1-2-1-651SAM201906R1112100.0366531PS1-3-1-651SAM201906R1113100.0606541PS1-4-1-651SAM201906R1114100.0876551PS1-5-1-651SAM201906R111510 0.1086522PS1-2-2-651SAM201906R1122100.0406532PS1-3-2-651SAM201906R1123100.0676542PS1-4-2-651SAM201906R1124100.0956552PS1-5-2-651SAM201906R1125100.122MS116, MS132, MO13210030PS1-3-0-1001SAM201916R1103100.08410040PS1-4-0-1001SAM201916R1104100.11710050PS1-5-0-1001SAM201916R1105100.15410031PS1-3-1-1001SAM201916R1113100.09410041PS1-4-1-1001SAM201916R1114100.13410051PS1-5-1-1001SAM201916R1115100.17210032PS1-3-2-1001SAM201916R112310 0.105Note: busbars are only suitable for screw versionsSuitable forRated operational currentRated cross sectionMounting formTy pe Order codePkgqtyWeight (1 pce)Amm²kgThree-phase feeder terminalsMS116, MS132, MO13265 25FlatS1-M1-251SAM201907R1101100.03865 25HighS1-M2-251SAM201907R1102100.05165 25UL/CSA Type E/F and IECS1-M3-251SAM201907R1103100.04210035UL/CSA Type E/F and IECS1-M3-351SAM201913R1103100.060Suitable forDescriptionTy pe Order codePkgqtyWeight (1 pce)kgMS116, MS132, MO132Protection cover for busbarsBS1-31SAM201908R1001500.003MS116, MS132, MO132, MS132-TScrew fixing kitFS1161SAM201909R100110.020Padlock + two keysSA2GJF1101903R0002100.020MS116Lock handleSA1GJF1101903R0001100.003Lock handle box SA1/SA2SA3GJF1101903R0003100.050Accessories for single-phase connection (IEC only)MS116, MS132, MO132, MS132-TPhase connecting linkPB1-1-321SAM201914R100110.009Phase power infeed blockS1-PB1-251SAM201914R100210.013PS1-2-0-65PS1-3-1-100S1-M1-25S1-M2-252CDC241023F0013SA2SA1PB1-1-32S1-PB1-252CDC241014F00101SBC101226F00141SBC101266F0014SK0108B912CDC241017F0010—AccessoriesMS116, MS132, MO132, MS132-T2CDC241004F00142CDC241005S001402
2CDC131050C02012/4 2ABB MOTOR PROTECTION AND CONTROLThree-phase busbars ensure a quick and safe connection and are therefore a cost effective solu-tion. A variety of different three-phase busbars up to 125 A are in the assortment. Between 2 and 4 manual motor starters with none, one or two lateral auxiliary contacts can be connected.Suitable forRated operational currentNumber of Manual motor startersNumber of lateral auxiliary contactsTy pe Order codePkgqtyWeight (1 pce)AkgThree-phase busbarsMS165, MO16512520PS2-2-0-1251SAM401920R100210 0.10012530PS2-3-0-1251SAM401920R1003100.16212540PS2-4-0-1251SAM401920R1004100.22612522PS2-2-2-1251SAM401920R1022100.11712532PS2-3-2-1251SAM401920R1023100.19712542PS2-4-2-1251SAM401920R1024100.277Other busbar types on request.Suitable forDescriptionTy pe Order codePkgqtyWeight (1 pce)kgMS165, MO165Terminal shroudKA1651SAM401922R1001100.025Protection cover for busbarsBS2-31SAM401921R1001100.005Padlock + two keysSA2GJF1101903R0002100.020PS2-2-0-1252CDC241003V0015PS2-3-0-125KA165BS2-32CDC241023F0013SA22CDC241010V0014—AccessoriesMS165, MO1652CDC241002V00152CDC241001V001502
2CDC131050C0201 ABB MOTOR PROTECTION AND CONTROL 2/43—AccessoriesMS116, MS132, MS165, MO132, MO165General technical dataTy pePS1-xxx-65PS1-xxx-100PS2-xxx-125S1-Mx-25S1-Mx-35StandardsIEC/EN 60947-4-1, IEC/EN 60947-1, UL 60947-1, UL 60947-4-1 (UL 508), CSA C22.2 No.60947-4-1 (CSA C22.2 No.14)Rated operational voltage Ue690 VRated operational voltage Ue acc. to UL/CSA600 V ACRated operational current Ie65 A100 A125 A65 A100 ARated operational current Ie acc. to UL/CSA 65 A92 A125 A65 A92 ARated frequency50/60 HzRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V ACPollution degree3Cross-section10 mm²16 mm²25 mm²25 mm²35 mm²Ambient air temperatureOperation-25 ... +70 °CStorage-50 ... +80 °CResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzElectrical connection - Main circuitTy peS1-Mx-25S1-Mx-35Connecting capacityRigid 1 x 6 ... 25 mm² 10 ... 35 mm²Flexible with ferrule1 x 6 ... 16 mm²10 ... 35 mm²Flexible with insulated ferrule1 x 6 ... 16 mm²10 ... 35 mm²Flexible1 x 6 ... 16 mm²10 ... 35 mm²Stranded acc. to UL/CSA1 x AWG 10-4AWG 8-2Stripping length10 mm12 mmTightening torque2.5 Nm / 22 Ib.in 4.5 Nm / 40 Ib.in Recommended screwdriverPozidriv 2Hexagon SW402
2CDC131050C02012/4 4ABB MOTOR PROTECTION AND CONTROLIB132 are IP65 (NEMA Type 12) enclosures for single manual motor starter installation. Additional mounting of auxiliary and signaling contacts, shunt trips and undervoltage release is possible. The handle is lockable in OFF position. For detailed specification see installation instruction. DMS132 are IP65 (NEMA Type 12) door mounting kits for manual motor starter installation in any en-closure. Additional mounting of auxiliary, signaling, shunt trips and undervoltage release is possi-ble. The handle is lockable in OFF position. For detailed specification see installation instruction.Suitable forDescriptionColorTy pe Order codePkgqtyWeight (1 pce)kgIP65 enclosures (NEMA Type 12)MS116, MS132, MO132Padlockable max. 3 padlocks with bail diameter 4 ... 6.5 mmYellow/redIB132-Y1SAM201911R101110.370Grey/blackIB132-G1SAM201911R101010.370IP65 door mounting kits (NEMA Type 12)MS116, MS132, MO132Padlockable max. 3 padlocks with bail diameter 4 ... 6.5 mmYellow/redDMS132-Y1SAM201912R101110.170Grey/blackDMS132-G1SAM201912R101010.170Indication I-O-T and ON-OFF-T.2CDC241004F0010IB132-Y2CDC241003F0010IB132-G 2CDC241002F0010DMS132-Y 2CDC241001F0010DMS132-G—AccessoriesMS116, MS132, MO132I ON0OFF119 118 183174 194 4.69"4.65"7.2"6.85"7.64"I ON0OFF135.7 9224121 116.15 5.34" 3.62" .94" 4.76" 4.57"IB132DMS132Main dimensions mm, inches02
2CDC131116C0201 ABB MOTOR PROTECTION AND CONTROL 2/45—AccessoriesMS116, MS132, MS165, MO132, MO165With this solution of door coupling rotary mechanisms it is possible to operate manual motor starters in the back of a switch cabinet from outside. The door coupling mechanism prevents opening of the door of a switch cabinet with the manual motor starter in ON position.The complete mechanism includes handle, shaft, driver, shaft alignment ring and shaft supporter.Most accessories fit for 6 mm shafts with a maximum length of 180 mm. The degree of protection for handles MSHD is IP64 (NEMA Type 1, 3R, 12).Suitable forDescriptionShaft lengthColorTy pe Order codePkgqtyWeight (1 pce)mmpcekgShaftsMS116, MS132, MO132, MS165, MO165For MSHD handles. Shaft diameter 6 mm. Shaft extension for door coupling driver.85OXS6X851SCA101647R100110.020105OXS6X1051SCA108043R100110.020130OXS6X1301SCA101655R100110.030180OXS6X1801SCA101659R100110.040IP64 handles (NEMA Type 1, 3R, 12)MS116, MS132, MO132, MS165, MO165Padlockable max. 3 padlocks with bail diameter 5 ... 8 mm, door interlock in ON position defeatable, for use with 6 mm OXS6...types up to 180 mm or driver shafts MSOX.BlackMSHD-LB (1)1SAM201920R100110.065YellowMSHD-LY (1)1SAM201920R100210.065BlackMSHD-LTB (2)1SAM201920R101110.065YellowMSHD-LTY (2)1SAM201920R101210.065DriverMS116, MS132, MO132, MS165, MO165Coupling driver for use with 6 mm OXS6... types up to 180 mm.MSMN (3)1SAM101923R000210.002MSMNO (4)1SAM101923R001210.002Shaft alignment ringMS116, MS132, MO132, MS165, MO165The MSH-AR supports the long shafts for alignment to the handle inlet. It makes closing panel doors more easy. Use for OXS6X > 105 mm.MSH-AR1SAM201920R100010.010Shaft supporterMS116, MS132, MO132With the MSAH it is possible to support the shaft in the extension of handle (MSHD). It is mandatory for the usage of shafts >130 mm.MSAH11SAM201909R102110.035(1) Indication I-O and ON-OFF (recommended for MS116)(2) Indication I-O and ON-OFF + Trip indication(3) Coded - Positioning of ON indication dependent on mounting orientation of the MMS(4) Uncoded - Positioning of ON indication independent of mounting orientation of the MMS. 2CDC241003F0011MSHD-LB2CDC241002S0011MSHD-LY2CDC241004F0011MSMN2CDC241001F0012MSH-AR2CDC241017V0013MSAH102
2CDC131116C02012/4 6ABB MOTOR PROTECTION AND CONTROL—AccessoriesMS116, MS132, MS165, MO132, MO165(1) MSAH1 fits to MS116,MS132 and MO132MSAH1MSMNMSMNOMSH-AROXS6XMSHD02
ABB MOTOR PROTECTION AND CONTROL 2/4702—Notes
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 www.abb.com/productdetails/1SBL137001R1310or
—AF, EK contactors and NF contactor relays3/3 Overview3/11 AF 3-pole contactors3/81 AF..K 3-pole contactors with Push-in Spring terminals3/107 AFS 3-pole contactors for safety applications3/131 AF and EK 4-pole contactors3/169 GAF Contactors for DC switching3/191 UA..RA Contactors for capacitor switching3/207 NF 4-pole and 8-pole contactor relays3/227 Accessories for AF09 ... AF2850 3-pole contactors, AF09 ... AF370 4-pole contactors and NF contactor relays3/271 Accessories for UA, UA..RA contactors and GA75, GAE75, GAF contactors3/297 Accessories for EK550, EK1000 4-pole contactors3/309 3/321 Terminal marking and positioning Dimensions3/385 Other contactor application data 3/404 Voltage code table3/409 Questionnaire for product specificationsABB MOTOR PROTECTION AND CONTROL 3/103
3/2ABB MOTOR PROTECTION AND CONTROL03
ABB MOTOR PROTECTION AND CONTROL 3/31SBC100200S0201 - Rev. A—AF contactors for motor starting and power switching up to 2850 AThe latest technology of electronically controlled coil is our standard. It offers multiple benefits over conventional alternatives, and together with ABB's wide product offering, it is an optimal configuration, every time.Optimized logisticsCut your costsWith its contactor and motor protection range, ABB has managed to reduce the number of con-tactor coils to just four. Total number of product variants has been re-duced by up to 90%. This simplifies the custom-ers' logistics while cutting storage and adminis-tration costs.Continuous operationSecure uptimePrevent stoppages caused by voltage fluctua-tions. The AF contactor ensures distinct opera-tion in unstable networks and signifies a major advance in motor control and power switching. Voltage sags, dips and surges pose no threat. The AF contactor secures your uptime.Speed up your projectsSimplify designUse the same part number in Europe, Asia and North America as one contactor coil now handles 100 V – 250 V AC / DC, 50 / 60 Hz. By reducing contactor coil energy consumption by up to 80%, panels can be built smaller and transformers more compact.03
—AF technologyMain BenefitsWide control voltage rangeWith conventional contactor technology, different contac-tors are needed for different network voltages. Thanks to the wide operating range of the AF contactor, it can operate just as well in Europe as in Asia or North America. The core coil of the AF contactor range covers 100-250 V AC / DC, 50 / 60 Hz. Reliable in all networksThe electronic system within the AF contactor continuously monitor the current and voltage apply to the coil. The con-tactor is safely operated in an always optimized condition and hum free. Built-in surge suppressionWith conventional contactor technology, it is recommended to use an external surge suppressor, an accessory that could cost as much as half of the contactor. With the AF technol-ogy, the surges are handled by the contactor and never reach the control circuit. One less product and one less complica-tion to worry about. Reduced coil consumptionAF coil and energy consumption is reduced up to 80%. This allows a reduction of the temperature rise, the size of control transformers and size of cabinets.AF coilAF coilConventional coil275 V250 V253 V230 V220 V87 V65 V60 V100 VSafe holding zoneUncertain drop zone85 V60 V- 5 %+ 10 %+ 10 %- 15 %+ 10 % UC max according to IECCoil nominal voltage-15 % uc min according to IECConventional AC coilEnergyTime80%Reduced coil consumption3/4ABB MOTOR PROTECTION AND CONTROL1SBC100202S020103
—Select AF contactor dedicated to your control circuit application–AF09Z...AF38Z designed for PLC - 4 to 18.5 kW - 24 V DC operatedVoltage range Coil code24 V DC 30•Allow direct control by 24 V DC ≥ 250 mA PLC-output•Pull-in consumption 6 W 250 mA•Holding consumption 1.7 W•NO contact opening time 29 ms and closing time 53 ms•With built-in surge protection–AF09...AF2850 - 4 to 400kW - AC / DC operated•AC / DC operation•Wide control voltage range•With built-in surge protectionAF09...AF370 Coil code24...60 V AC / DC 1148...130 V AC / DC 12100...250 V AC / DC 13250 V...500 V AC / DC 14AF400...AF125024...60 V DC 6848...130 V AC / DC 69100...250 V AC / DC 70250 V...500 V AC / DC 71AF1350...AF2850100...250 V AC / DC 70+ 10%- 15%275 V250 V100 V85 VDirect coil controlContactor coils are operated directly with an auxil-iary contact or PLC-output or indirectly through an interface relay. For direct coil control, the switching capacity of coil operating device (auxiliary contact, solid state PLC-output, ...) must be verified versus the coil consumption at closing and at holding.–AF09Z...AF38Z for specific applications - 4 to 18.5 kW - AC / DC operatedVoltage range Coil code12...60 V DC 2024...60 V AC / DC 2148...130 V AC / DC 22100 V...250 V AC / DC 23•Coil 20 covers 12 ... 20 V DC applications•Coil allow direct control by 24 V DC ≥ 500 mA PLC-output•Coil 21, 22 and 23 can withstand short voltage sags ans dips with reference to SEMI F47 conditions of use•With built-in surge protectionABB MOTOR PROTECTION AND CONTROL 3/51SBC100202S020103
—Select your AF coil interface for PLCFor contactors up to 2850 A AC-1 / General useCoil interfaces are offered to operate all contactor size up to AF2850 with very low PLC ouput signals. They allow a galvanic isolation between the PLC circuit and the contactor coil circuit.Control inputs with PLC plugControl circuit with interface relay24 V DC24 V DCA0E2--+E1+KM1A1A2PLCOutputA2RA4≤250 V ACUcInterface relayFor control with 24 V DC ≥ 20 mA PLC output. RA4 interface relay can be used for rated control circuit voltages Uc 24 ... 250 V 50/60Hz and 24 V DC with the standard AF contactors up to 45kW - 400 V / 60hp - 480 V and with NF contactor relays.Built-in PLC interfaceFor control with 24 V DC ≥ 10 mA PLC output. The built-in PLC interface operates the 100 ... 250 V AC / DC or 250 ... 500 V AC / DC AF contactor coil. Available for AF contactors from 55 kW - 400 V / 75 hp up to 560 kW - 400 V /900 hp 480 V and up to 2850 A AC-1 / General use. Dedi-cated coil code from AF116 up to AF370 and standard feature from AF400 up to AF2850.AF116AF2850AF09AF96RA43/6ABB MOTOR PROTECTION AND CONTROL1SBC100202S020103
—Contactors and motor protectionAdvanced but simpleProtect from overload in all conditionsSelect thermal overload relays (trip class 10) or electronic overload relays (trip class 10E, 20E, 30E in the same product) to protect your motors against overload and phase failure.Easy, fast and secure starters assemblyThe AF contactor range is perfect for motor starting applications and for solutions where space is limited. You can create any motor starting type and save assembly time with a complete range of accessories and connection sets.Compact sizeThe AF contactor is compact in size and has had its width reduced by up to 30% thanks to an 80% coil consumption reduction.Save space Interlocking reversing pairs require no spacing between contactors, meaning you can fit more functionality into cabinets or other enclosures. ABB MOTOR PROTECTION AND CONTROL 3/71SBC100202S020103
—Contactors and motor protectionFlexible and safeSimple connection and maintenanceThe main terminals of AF116 ... AF2850 contactors are at the contactors' back to facilitate your bus bars connections. It also allows easy contact inspection and maintenance from AF400 and above.Great flexibility for coil terminal accessContactors offer free choice of coil terminal access from top, bottom, both top and bottom or front.Easy to use accessories 1-pole, 2-pole and 4-poleauxiliary contact blocks, frontor side mounted, are availablefor a great flexibility.—Up to 96 A—Up to 2850 A 2 side mounted auxiliary contact blocks AF116 ... AF2850 contactors can take up to 2 side mounted auxiliary contact blocks without adding to its width. Coil connection terminals, mechanical and electrical interlocks and electronic timers are easily connected through the snap-to-connect function.Easy to use accessories 3/8ABB MOTOR PROTECTION AND CONTROL1SBC100202S020103
ABB MOTOR PROTECTION AND CONTROL 3/9—Notes03
—AF 3-pole contactors3/12 OverviewOrdering details4 to 200 kW3/14 AF09 ... AF38 AC / DC operated3/15 AF09Z ... AF38Z 24 V DC operated designed for PLC3/16 AF09Z ... AF38Z AC / DC operated for specific applications3/17 AF40 ... AF96 AC / DC operated3/18 AF09 ... AF96 Contactors and main accessories3/19 AF116 ... AF146 AC / DC operated3/20 AF116 ... AF146 AC / DC operated with built-in PLC interface3/21 AF190 ... AF370 AC / DC operated3/22 AF190 ... AF370 AC / DC operated with built-in PLC interface3/23 AF116 ... AF370 Contactors and main accessories4 to 560 kW (up to 2850 A AC-1) - with 1 N.O. + 1 N.C.3/24 AF26 ... AF38 AC / DC operated 3/25 AF26Z ... AF38Z AC / DC operated for specific applications 3/26 AF26 ... AF38 Contactors and main accessories3/27 AF40 ... AF96 AC / DC operated 3/28 AF40 ... AF96 Contactors and main accessories3/29 AF116 ... AF146 AC / DC operated 3/30 AF116 ... AF146 AC / DC operated with built-in PLC interface3/31 AF190 ... AF370 AC / DC operated 3/32 AF190 ... AF370 AC / DC operated with built-in PLC interface3/33 AF116 ... AF370 Contactors and main accessories3/34 AF400 ... AF750 AC / DC operated3/35 AF1250 ... AF2850 AC / DC operated3/36 AF1350T ... AF2850T AC / DC operated 3/37 AF400 ... AF2850 Main accessories4 to 560 kW (up to 2850 A AC-1) - with 2 N.O. + 2 N.C.3/38 AF09 ... AF38 AC / DC operated3/39 AF09Z ... AF38Z AC / DC operated for specific applications 3/40 AF40 ... AF96 AC / DC operated 3/41 AF09 ... AF96 Contactors and main accessories3/42 AF116 ... AF146 AC / DC operated 3/43 AF116 ... AF146 AC / DC operated with built-in PLC interface3/44 AF190 ... AF370 AC / DC operated3/45 AF190 ... AF370 AC / DC operated with built-in PLC interface3/46 AF116 ... AF370 Contactors and main accessories3/47 AF400 ... AF750 AC / DC operated 3/48 AF1250 ... AF2850 AC / DC operated3/49 AF400 ... AF2850 Contactors and main accessories3/50 Technical data3/74 Electrical durability — For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 www.abb.com/productdetails/1SBL137001R1310orABB MOTOR PROTECTION AND CONTROL 3/1103
—3-pole contactors, for motor controland power switchingAC / DC Control supplyTy peAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96AF116AF140AF146AF190AF205AF265AF305AF370AF400AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850IECAC-3Rated operational powerθ ≤ 60 °C for AF09 ... AF370θ ≤ 55 °C for AF400 ... AF2650220 - 230 - 240 VkW2.2346.5911111518.5 222530374555557590110110132160220—257315———380 - 400 V kW45.57.5111518.518.5 2230374555757590110132160200200250315400—475560———415 VkW45.59111518.5223037455555757590110132160200220250355425—500630———440 VkW45.591518.5222230374555759090110132160160200220250355450—560710———500 V kW5.5 7.591518.5222230374555759090110132160200250250315400520—560710———690 VkW5.5 7.591518.5222230374555557590132160200250315315355500600—8001000———1000 VkW—————————3540——75110132160185200220280355400——————Rated operational current380 - 400 V A912182632384053658096116140146190205265305370400460580750—8601060———AC-1Rated operational currentθ ≤ 40 °C, 690 V A252830455050701001051251301602002252753504005006006007008001050126013501650205026502850UL / CSA1-phase motor rating120 V hp0.7511.52223357.57.5——————————————————240 Vhp1.5233557.510151520——————————————————3-phase motor rating200 - 208 Vhp2357.5 10101015202530304040506075100125125150200250——————220 - 240 Vhp2357.5 101015202530304050506075100125150150200250300—400450———440 - 480 Vhp57.510152025304050606075100100125150200250300350400500600—800900———550 - 600 V hp7.5 10152025304050607575100125125150200250300350400500600700—10001150———General use rating600 V A252830455050608090105115160200200250300350400520550650750900121013501650210027002850NEMANEMA Size000—1——2——3——4———5———6—7——8———Main accessoriesAuxiliary contact blocksFront mountingCA4-10 (1 x N.O.) CA4-01 (1 x N.C.)Side mountingCAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11 (1 x N.O. + 1 x N.C.)CAL18-11 (1 x N.O. + 1 x N.C.)TimersElectronicTEF4-ONTEF4-OFFInterlocking unitsMechanicalVM4VM96-4VM19 (for same size contactors)VM750HVM750VVM1650HMechanical / ElectricalVEM4Connection setsFor reversing contactorsBER16-4BER38-4BER65-4BER96-4BER140-4BER205-4BER370-4BEM460-30BEM750-30Surge suppressorsBuilt-in surge protectionOverload relaysThermal relaysClass 10 (Class 10A for TF140, TA200DU)TF42 (0.10...38 A)TF65 (22...67 A)TF96 (40...96 A)TF140DU (66...142 A) θ ≤ 55 °CTA200DU(66...200 A)θ ≤ 55 °CElectronic relaysClass 10E, 20E, 30EEF19 (0.10...18.9 A)EF19 (0.10...18.9 A)EF45 (9...45 A)EF65 (20...70 A)EF96 (36...100 A)EF146 (54...150 A)EF205 (63...210 A) EF370 (115...380 A)EF460 (150...500 A) EF750 (250...800 A)EF1250DU (350...1250 A)Manual motor startersThermal / magnetic protectionClass 10MS116 (0.10...32 A)lcs up to 50 kA for class 10 AMS165 (10...80 A)lcs up to 100 kA (1)MS132 (0.10...32 A)lcs up to 100 kAMagnetic only typesMO132 (0.16...32 A)Ics up to 100 kAMO165 (16...80 A)lcs up to 100 kA (1)AccessoriesFor contactor mountingBEA16-4BEA38-4BEA65-4 (2)(1) MS165/MO165 are suitable for use with AF09 ... AF30 for North american applications.(2) BEA65-4 suitable for MS165 and MO165 only.3/12ABB MOTOR PROTECTION AND CONTROL03
AC / DC Control supplyTy peAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96AF116AF140AF146AF190AF205AF265AF305AF370AF400AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650AF2850IECAC-3Rated operational powerθ ≤ 60 °C for AF09 ... AF370θ ≤ 55 °C for AF400 ... AF2650220 - 230 - 240 VkW2.2346.5911111518.5 222530374555557590110110132160220—257315———380 - 400 V kW45.57.5111518.518.5 2230374555757590110132160200200250315400—475560———415 VkW45.59111518.5223037455555757590110132160200220250355425—500630———440 VkW45.591518.5222230374555759090110132160160200220250355450—560710———500 V kW5.5 7.591518.5222230374555759090110132160200250250315400520—560710———690 VkW5.5 7.591518.5222230374555557590132160200250315315355500600—8001000———1000 VkW—————————3540——75110132160185200220280355400——————Rated operational current380 - 400 V A912182632384053658096116140146190205265305370400460580750—8601060———AC-1Rated operational currentθ ≤ 40 °C, 690 V A252830455050701001051251301602002252753504005006006007008001050126013501650205026502850UL / CSA1-phase motor rating120 V hp0.7511.52223357.57.5——————————————————240 Vhp1.5233557.510151520——————————————————3-phase motor rating200 - 208 Vhp2357.5 10101015202530304040506075100125125150200250——————220 - 240 Vhp2357.5 101015202530304050506075100125150150200250300—400450———440 - 480 Vhp57.510152025304050606075100100125150200250300350400500600—800900———550 - 600 V hp7.5 10152025304050607575100125125150200250300350400500600700—10001150———General use rating600 V A252830455050608090105115160200200250300350400520550650750900121013501650210027002850NEMANEMA Size000—1——2——3——4———5———6—7——8———Main accessoriesAuxiliary contact blocksFront mountingCA4-10 (1 x N.O.) CA4-01 (1 x N.C.)Side mountingCAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11 (1 x N.O. + 1 x N.C.)CAL18-11 (1 x N.O. + 1 x N.C.)TimersElectronicTEF4-ONTEF4-OFFInterlocking unitsMechanicalVM4VM96-4VM19 (for same size contactors)VM750HVM750VVM1650HMechanical / ElectricalVEM4Connection setsFor reversing contactorsBER16-4BER38-4BER65-4BER96-4BER140-4BER205-4BER370-4BEM460-30BEM750-30Surge suppressorsBuilt-in surge protectionOverload relaysThermal relaysClass 10 (Class 10A for TF140, TA200DU)TF42 (0.10...38 A)TF65 (22...67 A)TF96 (40...96 A)TF140DU (66...142 A) θ ≤ 55 °CTA200DU (66...200 A)θ ≤ 55 °CElectronic relaysClass 10E, 20E, 30EEF19 (0.10...18.9 A)EF19 (0.10...18.9 A)EF45 (9...45 A)EF65 (20...70 A)EF96 (36...100 A)EF146 (54...150 A)EF205 (63...210 A) EF370 (115...380 A)EF460 (150...500 A) EF750 (250...800 A)EF1250DU (350...1250 A)Manual motor startersThermal / magnetic protectionClass 10MS116 (0.10...32 A)lcs up to 50 kA for class 10 AMS165 (10...80 A)lcs up to 100 kA (1)MS132 (0.10...32 A)lcs up to 100 kAMagnetic only typesMO132 (0.16...32 A)Ics up to 100 kAMO165 (16...80 A)lcs up to 100 kA (1)AccessoriesFor contactor mountingBEA16-4BEA38-4BEA65-4 (2)(1) MS165/MO165 are suitable for use with AF09 ... AF30 for North american applications.(2) BEA65-4 suitable for MS165 and MO165 only. ABB MOTOR PROTECTION AND CONTROL 3/1303
1SBC101011V0014AF09-30-101SBC101001V0014AF26-30-00—AF09 ... AF38 3-pole contactors4 to 18.5 kWAC / DC operatedAF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening.•built-in surge suppression •add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg42552524...6020...60(1)1 0AF09-30-10-111SBL137001R11100.2700 1AF09-30-01-111SBL137001R11010.27048...13048...1301 0AF09-30-10-121SBL137001R12100.2700 1AF09-30-01-121SBL137001R12010.270100...250 100...2501 0AF09-30-10-131SBL137001R13100.2700 1AF09-30-01-13 1SBL137001R13010.270250...500 250...5001 0AF09-30-10-141SBL137001R14100.3100 1AF09-30-01-141SBL137001R14010.3105.5287.52824...6020...60(1)1 0AF12-30-10-111SBL157001R11100.2700 1AF12-30-01-111SBL157001R11010.27048...13048...1301 0AF12-30-10-121SBL157001R12100.2700 1AF12-30-01-121SBL157001R12010.270100...250 100...2501 0AF12-30-10-13 1SBL157001R13100.2700 1AF12-30-01-131SBL157001R13010.270250...500 250...5001 0AF12-30-10-141SBL157001R14100.3100 1AF12-30-01-141SBL157001R14010.3107.530103024...6020...60(1)1 0AF16-30-10-111SBL177001R11100.2700 1AF16-30-01-111SBL177001R11010.27048...13048...1301 0AF16-30-10-121SBL177001R12100.2700 1AF16-30-01-121SBL177001R12010.270100...250 100...2501 0AF16-30-10-131SBL177001R13100.2700 1AF16-30-01-131SBL177001R13010.270250...500 250...5001 0AF16-30-10-141SBL177001R14100.3100 1AF16-30-01-141SBL177001R14010.3101145154524...6020...60(1)0 0AF26-30-00-111SBL237001R11000.31048...13048...1300 0AF26-30-00-121SBL237001R12000.310100...250 100...2500 0AF26-30-00-13 1SBL237001R13000.310250...500 250...5000 0AF26-30-00-141SBL237001R14000.3501550205024...6020...60(1)0 0AF30-30-00-111SBL277001R11000.31048...13048...1300 0AF30-30-00-121SBL277001R12000.310100...250 100...2500 0AF30-30-00-131SBL277001R13000.310250...500 250...5000 0AF30-30-00-141SBL277001R14000.35018.550255024...6020...60(1)0 0AF38-30-00-111SBL297001R11000.31048...13048...1300 0AF38-30-00-121SBL297001R12000.310100...250 100...2500 0AF38-30-00-13 1SBL297001R13000.310250...500 250...5000 0AF38-30-00-141SBL297001R14000.350(1) AF..-30-..-11 not suitable for direct control by PLC-output.45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF09, AF12, AF1635 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26, AF30, AF38Main dimensions mm, inches1SBC101371S0201 - Rev. D3/14ABB MOTOR PROTECTION AND CONTROL03
1SBC101525V0014AF09Z-30 -101SBC101525V0014AF26Z-30-00—AF09Z ... AF38Z 3-pole contactors4 to 18.5 kW24 V DC operated designed for PLCAF09Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.• control circuit: 24 V DC operated with electronic coil interface allowing low holding consumption up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUcAuxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV DCkg425525241 0AF09Z-30-10-301SBL136001R30100.4300 1AF09Z-30-01-301SBL136001R30010.4305.5287.528241 0AF12Z-30-10-301SBL156001R30100.4300 1AF12Z-30-01-301SBL156001R30010.4307.5301030241 0AF16Z-30-10-301SBL176001R30100.4300 1AF16Z-30-01-301SBL176001R30010.43011451545240 0AF26Z-30-00-301SBL236001R30000.48015502050240 0AF30Z-30-00-301SBL276001R30000.48018.5502550240 0AF38Z-30-00-301SBL296001R30000.480Note: AF..Z contactors with DC control voltage 24 V DC need to respect the connection polarities indicated close to the coilterminals: A1+ for the positive pole and A2- for the negative pole.45 1.77"80 3.15"6 0.24"97 3.82"91 3.58"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inchesAF26Z, AF30Z, AF38ZAF09Z, AF12Z, AF16Z35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"106 4.17"100 3.94"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"1SBC100328S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/1503
Main dimensions mm, inches1SBC101011V0014AF09Z-30 -101SBC101001V0014AF26Z-30-00—AF09Z ... AF38Z 3-pole contactors4 to 18.5 kWAC / DC operated for specific applications45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF09Z, AF12Z, AF16Z35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26Z, AF30Z, AF38ZAF09Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC - can manage large control voltage variations -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).•built-in surge suppression •add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg425525-12...201 0AF09Z-30-10-201SBL136001R20100.3100 1AF09Z-30-01-201SBL136001R20010.31024...6020...601 0AF09Z-30-10-211SBL136001R21100.3100 1AF09Z-30-01-211SBL136001R21010.31048...130 48...1301 0AF09Z-30-10-221SBL136001R22100.3100 1AF09Z-30-01-221SBL136001R22010.310100...250 100...2501 0AF09Z-30-10-231SBL136001R23100.3100 1AF09Z-30-01-231SBL136001R23010.3105.5287.528-12...201 0AF12Z-30-10-201SBL156001R20100.3100 1AF12Z-30-01-201SBL156001R20010.31024...6020...601 0AF12Z-30-10-211SBL156001R21100.3100 1AF12Z-30-01-211SBL156001R21010.31048...130 48...1301 0AF12Z-30-10-221SBL156001R22100.3100 1AF12Z-30-01-221SBL156001R22010.310100...250 100...2501 0AF12Z-30-10-231SBL156001R23100.3100 1AF12Z-30-01-231SBL156001R23010.3107.5301030-12...201 0AF16Z-30-10-201SBL176001R20100.3100 1AF16Z-30-01-201SBL176001R20010.31024...6020...601 0AF16Z-30-10-211SBL176001R21100.3100 1AF16Z-30-01-211SBL176001R21010.31048...130 48...1301 0AF16Z-30-10-221SBL176001R22100.3100 1AF16Z-30-01-221SBL176001R22010.310100...250 100...2501 0AF16Z-30-10-231SBL176001R23100.3100 1AF16Z-30-01-231SBL176001R23010.31011451545-12...200 0AF26Z-30-00-201SBL236001R20000.35024...6020...600 0AF26Z-30-00-211SBL236001R21000.35048...130 48...1300 0AF26Z-30-00-221SBL236001R22000.350100...250 100...2500 0AF26Z-30-00-231SBL236001R23000.35015502050-12...200 0AF30Z-30-00-201SBL276001R20000.35024...6020...600 0AF30Z-30-00-211SBL276001R21000.35048...130 48...1300 0AF30Z-30-00-221SBL276001R22000.350100...250 100...2500 0AF30Z-30-00-231SBL276001R23000.35018.5502550-12...200 0AF38Z-30-00-201SBL296001R20000.35024...6020...600 0AF38Z-30-00-211SBL296001R21000.35048...130 48...1300 0AF38Z-30-00-221SBL296001R22000.350100...250 100...2500 0AF38Z-30-00-231SBL296001R23000.350Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.1SBC101372S0201 - Rev. C3/16ABB MOTOR PROTECTION AND CONTROL03
1SBC101740S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/17—AF40 ... AF96 3-pole contactors 18.5 to 45 kWAC / DC operatedAF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType (1)Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating 600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg18.570306024...6020...60(1)0 0AF40-30-00-111SBL347001R11000.97048...13048...1300 0AF40-30-00-121SBL347001R12000.970100...250 100...2500 0AF40-30-00-131SBL347001R13000.950250...500 250...5000 0AF40-30-00-141SBL347001R14000.95022100408024...6020...60(1)0 0AF52-30-00-111SBL367001R11000.97048...13048...1300 0AF52-30-00-121SBL367001R12000.970100...250 100...2500 0AF52-30-00-13 1SBL367001R13000.950250...500 250...5000 0AF52-30-00-141SBL367001R14000.95030105509024...6020...60(1)0 0AF65-30-00-111SBL387001R11000.97048...13048...1300 0AF65-30-00-121SBL387001R12000.970100...250 100...2500 0AF65-30-00-13 1SBL387001R13000.950250...500 250...5000 0AF65-30-00-141SBL387001R14000.950371256010524...6020...60(1)0 0AF80-30-00-111SBL397001R11001.22048...13048...1300 0AF80-30-00-121SBL397001R12001.220100...250 100...2500 0AF80-30-00-131SBL397001R13001.170250...500 250...5000 0AF80-30-00-141SBL397001R14001.170451306011524...6020...60(1)0 0AF96-30-00-111SBL407001R11001.22048...13048...1300 0AF96-30-00-121SBL407001R12001.220100...250 100...2500 0AF96-30-00-13 1SBL407001R13001.170250...500 250...5000 0AF96-30-00-141SBL407001R14001.170(1) For control by PLC-output, use R A4 interface relay.1SBC101014V0014AF40-30-001SBC101016V0014AF80-30-00111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"5.50.22"111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"5.50.22"AF40, AF52, AF656 0.24"119.5 4.70"70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 607155.5 0.22"6 0.24"119.5 4.70"70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 607155.5 0.22"AF80, AF96Main dimensions mm, inches03
VEM4 mechanical and electrical interlock set Including: - VM4 mechanical interlock unit with 2 fixing clips -VE4 electrical inlerlock block with A2-A2 connection—AF09 ... AF96 3-pole contactorsContactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMain polesBuilt-in auxiliary contactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerMechanical latching unitElectrical and Auxiliary contact blocksmechanical interlock set(between 2 contactors)2-pole CAL4-11 1-pole CA42-pole CAT4-11 4-pole CA4TEF4WA4 (2) VEM4Left sideRight sideAF09(Z) ... AF38(Z) (1)AF09 ... AF163 00 14 max.or 1or 1or 1or 1–+1–AF09 ... AF163 01 02 max.or 1–or 1or 1–+1+ 1AF26 ... AF383 00 03 max.––––+ 1 (3)+1or 1AF09Z ... AF38Z 24 V DC designed for PLC - coil 30 (1)AF09Z ... AF16Z 3 00 14 max.–or 1or 1–– (3)or1+ 1AF09Z ... AF16Z 3 01 02 max.––or 1–– (3)+1or 1AF26Z ... AF38Z 3 00 0–––1––+1+ 1AF40 ... AF96AF40 ... AF653 0 0 04 max.or 1or 1or 1or 1–+1+ 1AF80, AF963 0 0 04 max.–or 1or 1or 1–+1+ 1(1) I ncluding add-on and built-in contacts : 4 N.C. auxiliary contacts max on positions 1, 2, 3, 4 and 3 N.C. auxiliary contacts max. on positions 1 ±30°, 5.(2) Use WA4 for AF09...AF65 and WA4-96 for AF80, AF96. Accept 1-pole CA4 auxiliary contacts (1 block on each side of the mechanical latch) in respect to the total number of built-in or additional N.C. auxiliary contacts.For WA4 accessory use with contactor coil 30, please consult your ABB local sales organization.(3) VEM4 not suitable for AF..Z contactors with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30). Use VM4 side-mounted mechanical interlock unit.Overload relays fitting details (4)Contactor typesThermal overload relaysElectronic overload relays AF09 ... AF38TF42 (0.10...38 A)EF19 (0.10...19 A)AF26 ... AF38TF42 (0.10...38 A)EF45 (9...45 A)AF40 ... AF65TF65 (22...67 A)EF65 (20...70 A)AF80, AF96TF96 (40...96 A)EF96 (36...100 A)The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(4) Direct mounting - No kit required.AF09 ... AF65 contactorsAF09 ... AF96 contactorsTFEFOverload relayCAL4-112-pole auxiliarycontact blockCA41-pole auxiliarycontact blockVE4CA41-pole auxiliarycontact blockA2-A2 connectionCA41-pole auxiliarycontact blockCAL4-112-pole auxiliarycontact blockCA44-pole auxiliary contact blockFixing clipsVM..Mechanical interlock unitCAT4-112-pole auxiliary contactand A1/A2 coil terminal blockBX4-CAProtective coverTEF4Electronic timerBX4-CAProtective coverBX4-CAProtective coverBX4Protective coverWA4Mechanicallatching unitAF09 ... AF38 contactors(without coil terminal block)X1SBC101748S0201 - Rev. A3/18ABB MOTOR PROTECTION AND CONTROL03
ABB MOTOR PROTECTION AND CONTROL 3/191SFC101088C0201 - Rev. D1SFC101005V0001AF146-30-001SFC101006V0001AF146-30-00B—AF116 ... AF146 3-pole contactors55 to 75 kWAC / DC operatedAF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps551607516024...6020...600 0AF116-30-00-111SFL427001R11001.75048...130 48...1300 0AF116-30-00-121SFL427001R12001.750100...250 100...2500 0AF116-30-00-13 1SFL427001R13001.750250...500 250...5000 0AF116-30-00-141SFL427001R14001.7507520010020024...6020...600 0AF140-30-00-111SFL447001R11001.75048...130 48...1300 0AF140-30-00-121SFL447001R12001.750100...250 100...2500 0AF140-30-00-131SFL447001R13001.750250...500 250...5000 0AF140-30-00-141SFL447001R14001.7507522510020024...6020...600 0AF146-30-00-111SFL467001R11001.75048...130 48...1300 0AF146-30-00-121SFL467001R12001.750100...250 100...2500 0AF146-30-00-13 1SFL467001R13001.750250...500 250...5000 0AF146-30-00-141SFL467001R14001.750With bar connections551607516024...6020...600 0AF116-30-00B-111SFL427002R11001.50048...130 48...1300 0AF116-30-00B-121SFL427002R12001.500100...250 100...2500 0AF116-30-00B-13 1SFL427002R13001.500250...500 250...5000 0AF116-30-00B-141SFL427002R14001.5007520010020024...6020...600 0AF140-30-00B-111SFL447002R11001.50048...130 48...1300 0AF140-30-00B-121SFL447002R12001.500100...250 100...2500 0AF140-30-00B-13 1SFL447002R13001.500250...500 250...5000 0AF140-30-00B-141SFL447002R14001.5007522510020024...6020...600 0AF146-30-00B-111SFL467002R11001.50048...130 48...1300 0AF146-30-00B-121SFL467002R12001.500100...250 100...2500 0AF146-30-00B-13 1SFL467002R13001.500250...500 250...5000 0AF146-30-00B-141SFL467002R14001.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.SECTION E-E 55.5 0.22"150 5.91"90 3.54"19.5 4.96"126 4.96"30 1.18"DDEESECTION E-E 55.5 2.18"19.5 0.77"126 4.96"90 3.54"150 5.91"30 1.18"DDAF116, AF140, AF146-30-00AF116, AF140, AF146-30-00BMain dimensions mm, inches03
1SFC101164C0201 - Rev. A3/20ABB MOTOR PROTECTION AND CONTROL1SFC101182V0001AF146-30-001SFC101185V0001AF146-30-00B—AF116 ... AF146 3-pole contactors with built-in PLC interface55 to 75 kWAC / DC operated for faster opening utilizationAF116 ... AF146 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...500 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...250 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps5516075160100...250 100...2500 0AF116-30-00-331SFL427001R33001.750250...500 250...5000 0AF116-30-00-341SFL427001R34001.75075200100200100...250 100...2500 0AF140-30-00-331SFL447001R33001.750250...500 250...5000 0AF140-30-00-341SFL447001R34001.75075225100200100...250 100...2500 0AF146-30-00-331SFL467001R33001.750250...500 250...5000 0AF146-30-00-341SFL467001R34001.750With bar connections5516075160100...250 100...2500 0AF116-30-00B-331SFL427002R33001.500250...500 250...5000 0AF116-30-00B-341SFL427002R34001.50075200100200100...250 100...2500 0AF140-30-00B-331SFL447002R33001.500250...500 250...5000 0AF140-30-00B-341SFL447002R34001.50075225100200100...250 100...2500 0AF146-30-00B-331SFL467002R33001.500250...500 250...5000 0AF146-30-00B-341SFL467002R34001.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.Control inputs55.5 0.22"90 3.54"19.5 4.96"30 1.18"DDE150 5.91"142.5 5.61"E55.5 2.18"19.5 0.77"142.5 5.61"90 3.54"150 5.91"30 1.18"DDAF116, AF140, AF146-30-00AF116, AF140, AF146-30-00BMain dimensions mm, inches03
ABB MOTOR PROTECTION AND CONTROL 3/211SFC101089C0201 - Rev. EAF205-30-00AF370-30-00—AF190 ... AF370 3-pole contactors90 to 200 kWAC / DC operatedAF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and 340 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType (1)Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg9027512525024...6020...600 0AF190-30-00-111SFL487002R11003.00048...130 48...1300 0AF190-30-00-121SFL487002R12003.000100...250 100...2500 0AF190-30-00-131SFL487002R13003.000250...500 250...5000 0AF190-30-00-141SFL487002R14003.00011035015030024...6020...600 0AF205-30-00-111SFL527002R11003.00048...130 48...1300 0AF205-30-00-121SFL527002R12003.000100...250 100...2500 0AF205-30-00-13 1SFL527002R13003.000250...500 250...5000 0AF205-30-00-141SFL527002R14003.00013240020035024...6020...600 0AF265-30-00-111SFL547002R11004.60548...130 48...1300 0AF265-30-00-121SFL547002R12004.605100...250 100...2500 0AF265-30-00-13 1SFL547002R13004.605250...500 250...5000 0AF265-30-00-141SFL547002R14004.60516050025040024...6020...600 0AF305-30-00-111SFL587002R11004.60548...130 48...1300 0AF305-30-00-121SFL587002R12004.605100...250 100...2500 0AF305-30-00-13 1SFL587002R13004.605250...500 250...5000 0AF305-30-00-141SFL587002R14004.60520060030052024...6020...600 0AF370-30-00-111SFL607002R11004.60548...130 48...1300 0AF370-30-00-121SFL607002R12004.605100...250 100...2500 0AF370-30-00-131SFL607002R13004.605250...500 250...5000 0AF370-30-00-141SFL607002R14004.605(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.B105 4.13"ø 8.5 0.33"35 1.38"152 5.98"83.5 3.29"196 7.72"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"AAF190, AF205AF265, AF305, AF370Main dimensions mm, inches1SFC101276V00011SFC101273V000103
1SFC101165C0201 - Rev. A3/22ABB MOTOR PROTECTION AND CONTROLAF205-30-00AF370-30-00—AF190 ... AF370 3-pole contactors with built-in PLC interface90 to 200 kWAC / DC operated for faster utilizationAF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and 340 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg90275125250100...250 100...2500 0AF190-30-00-331SFL487002R33003.000250...500 250...5000 0AF190-30-00-341SFL487002R34003.000110350150300100...250 100...2500 0AF205-30-00-331SFL527002R33003.000250...500 250...5000 0AF205-30-00-341SFL527002R34003.000132400200350100...250 100...2500 0AF265-30-00-331SFL547002R33004.605250...500 250...5000 0AF265-30-00-341SFL547002R34004.605160500250400100...250 100...2500 0AF305-30-00-331SFL587002R33004.605250...500 250...5000 0AF305-30-00-341SFL587002R34004.605200600300520100...250 100...2500 0AF370-30-00-331SFL607002R33004.605250...500 250...5000 0AF370-30-00-341SFL607002R34004.605(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.Control inputsB105 4.13"ø 8.5 0.33"35 1.38"196 7.72"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 169.5 6.67"140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A195.5 7.70"AF190, AF205AF265, AF305, AF370Main dimensions mm, inches1SFC101271V00011SFC101268V000103
—AF116 ... AF370 3-pole contactors Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Mechanical interlock unitsAuxiliary contact blocks(between two contactors)CAL19-11 (3)CAL19-11BAF116 ... AF3703 00 02 x CAL19-11+ 2 x CAL19-11B–AF116 ... AF3703 00 02 x CAL19-11 (1)+ 2 x CAL19-11B (1)+ VM... (2)(1) Total number of auxiliary contact blocks for the two contactors. (2) Interlock type, according to the contactor ratings (see "Accessories").(3) The CEL19 auxiliary contact blocks can replace the CAL19-11 and CAL19-11B. Though, no auxiliary contact block can be mounted outside the CEL19.Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relaysAF116 ... AF140TF140DU (66...142 A)EF146 (54...150 A)AF146–EF146 (54...150 A)AF190, AF205TA200DU (66...200 A)EF205 (63...210 A)AF265 ... AF370–EF370 (115...380 A)The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.(1) Direct mounting - No kit required.AF contactorwith bar connectionsCAL19-112-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-112-pole auxiliarycontact blockAF contactorwith built-in cable clampsVM Mechanical interlockLT Terminal shroudLW Te rmi n al enlargementT F/ TA Thermal overload relay EFElectronic overload relay ABB MOTOR PROTECTION AND CONTROL 3/231SFC101135C0201 - Rev. A03
1SBC100492S0201 - Rev. C3/24ABB MOTOR PROTECTION AND CONTROL1SBC101003V0014—AF26 ... AF38 3-pole contactors4 to 18.5 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF26 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):•2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC -can manage large control voltage variations -reduced panel energy consumption -very distinct closing and opening.•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc min. ... Uc max.AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg1145154524...6020...60(1)1 1AF26-30-11-111SBL237001R11110.35048...13048...1301 1AF26-30-11-121SBL237001R12110.350100...250 100...2501 1AF26-30-11-131SBL237001R13110.350250...500 250...5001 1AF26-30-11-141SBL237001R14110.3901550205024...6020...60(1)1 1AF30-30-11-111SBL277001R11110.35048...13048...1301 1AF30-30-11-121SBL277001R12110.350100...250 100...2501 1AF30-30-11-131SBL277001R13110.350250...500 250...5001 1AF30-30-11-141SBL277001R14110.39018.550255024...6020...60(1)1 1AF38-30-11-111SBL297001R11110.35048...13048...1301 1AF38-30-11-121SBL297001R12110.350100...250 100...2501 1AF38-30-11-131SBL297001R13110.350250...500 250...5001 1AF38-30-11-141SBL297001R14110.390(1) AF..-30-..-11 not suitable for direct control by PLC-output.45 1.77"80 3.15"6 0.24"111.5 4.30"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AF26, AF30, AF38AF26-30-11Main dimensions mm, inches03
1SBC100493S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/25—AF26Z ... AF38Z 3-pole contactors 4 to 18.5 kWAC / DC operated for specific applications with 1 N.O. + 1 N.C. contactsAF26Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):•2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC -can manage large control voltage variations, allow direct control by PLC-output ≥ 24 V DC 500 mA, reduced panel energy consumption, very distinct closing and opening, -can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc min. ... Uc max.AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg11451545-12...201 1AF26Z-30-11-201SBL236001R20110.39024...6020...601 1AF26Z-30-11-211SBL236001R21110.39048...13048...1301 1AF26Z-30-11-221SBL236001R22110.390100...250 100...2501 1AF26Z-30-11-231SBL236001R23110.39015502050-12...201 1AF30Z-30-11-201SBL276001R20110.39024...6020...601 1AF30Z-30-11-211SBL276001R21110.39048...13048...1301 1AF30Z-30-11-221SBL276001R22110.390100...250 100...2501 1AF30Z-30-11-231SBL276001R23110.39018.5502550-12...201 1AF38Z-30-11-201SBL296001R20110.39024...6020...601 1AF38Z-30-11-211SBL296001R21110.39048...13048...1301 1AF38Z-30-11-221SBL296001R22110.390100...250 100...2501 1AF38Z-30-11-231SBL296001R23110.390Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole1SBC101003V0014AF26Z-30-11Main dimensions mm, inches45 1.77"80 3.15"6 0.24"111.5 4.30"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AF26Z, AF30Z, AF38Z03
1SBC101750S0201 - Rev. B3/26ABB MOTOR PROTECTION AND CONTROL—AF26 ... AF38 3-pole contactors with 1 N.O. + 1 N.C. auxiliary contactsContactors and main accessoriesAF contactorCAL4-112-pole auxiliarycontact blockTF42EFOverload relayMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMain polesBuilt-in auxiliary contactsSide-mounted accessoriesAuxiliary contact blocksMechanical interlock unit(between 2 contactors)2-pole CAL4-11Left sideRight sideVM4AF26 ... AF383 01 11+1or 1–+1+ 1Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relays AF26 ... AF38TF42 (0.10...38 A)EF19 (0.10...19 A)EF45 (9...45 A)The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(1) Direct mounting - No kit required.BX4-CAProtective cover03
1SBC100487S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/27—AF40 ... AF96 3-pole contactors18.5 to 30 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack): • with 1 N.O. + 1 N.C. side mounted auxiliary contact block • control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating 480 VGeneral use rating 600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg18570306024...6020...60(1)1 1AF40-30-11-111SBL347001R11111.01048...130 48...1301 1AF40-30-11-121SBL347001R12111.010100...250 100...2501 1AF40-30-11-131SBL347001R13110.990250...500 250...5001 1AF40-30-11-141SBL347001R14110.99022100408024...6020...60(1)1 1AF52-30-11-111SBL367001R11111.01048...130 48...1301 1AF52-30-11-121SBL367001R12111.010100...250 100...2501 1AF52-30-11-13 1SBL367001R13110.990250...500 250...5001 1AF52-30-11-141SBL367001R14110.99030105509024...6020...60(1)1 1AF65-30-11-111SBL387001R11111.01048...130 48...1301 1AF65-30-11-121SBL387001R12111.010100...250 100...2501 1AF65-30-11-131SBL387001R13110.990250...500 250...5001 1AF65-30-11-141SBL387001R14110.990371256010524...6020...60(1)1 1AF80-30-11-111SBL397001R11111.26048...130 48...1301 1AF80-30-11-121SBL397001R12111.260100...250 100...2501 1AF80-30-11-131SBL397001R13111.210250...500 250...5001 1AF80-30-11-141SBL397001R14111.210451306011524...6020...60(1)1 1AF96-30-11-111SBL407001R11111.26048...130 48...1301 1AF96-30-11-121SBL407001R12111.260100...250 100...2501 1AF96-30-11-131SBL407001R13111.210250...500 250...5001 1AF96-30-11-141SBL407001R14111.210(1) For control by PLC-output, use R A4 interface relay.1SBC101005V0014AF40-30-111SBC101017V0014AF80-30-11111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"12 0.47"10 0.39"35 mm EN/IEC 607155.5 0.22" 111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"12 0.47"10 0.39"35 mm EN/IEC 607155.5 0.22" 6 0.24"119.5 4.70"5.5 0.22"70 2.76"116 4.57"10 0.39"35 x 15 mm EN/IEC 6071512 0.47"7 0.28"Main dimensions mm, inchesAF40, AF52, AF65-30-11-..AF80, AF96-30-11-..03
1SBC100495S0201 - Rev. B3/28ABB MOTOR PROTECTION AND CONTROL—AF40 ... AF96 3-pole contactors with 1 N.O. + 1 N.C. auxiliary contactsContactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMain polesBuilt-in auxiliary contactsFront-mounted accessoriesSide-mounted accessoriesMechanical interlock set(between 2 contactors)Auxiliary contact blocksAuxiliary contact blocksElectronic timerMechanical latching unit (1)1-pole CA42-pole CAL4-11 Left side2-pole CAT4-11 4-pole CA4TEF4 WA4VM96-4Right sideAF40 ... AF653 01 14 max.or 1or 1or 1or 1+ 1––4 max.or 1or 1or 1or 1–+–1AF80, AF963 01 14 max.–or 1or 1or 1+ 1––4 max.–or 1or 1or 1–+–1(1) Use WA4 for AF09...AF65 and WA4-96 for AF80, AF96.Accept 1-pole CA4 auxiliary contacts on each side of the mechanical latch.Overload relays fitting details (2)Contactor typesThermal overload relaysElectronic overload relays AF40 ... AF65TF65 (22...67 A)EF65 (20...70 A)AF80, AF96TF96 (40...96 A)EF96 (36...100 A)The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(2) Direct mounting - No kit required.AF40 ... AF65 contactorsAF40 ... AF96 contactorsCA41-pole auxiliary contact blockCA44-pole auxiliary contact blockFixing clipsVM96-4Mechanical interlock unitCAT4-112-poleauxiliary contactand A1/A2 coilterminal blockBX4-CAProtective coverTEF4Electronic timerWA4Mechanical latching unitBX4-CAProtective coverBX4-CAProtective coverBX4Protective cover(without coil terminal block)XTFEFOverload relay03
1SFC101090C0201 - Rev. D ABB MOTOR PROTECTION AND CONTROL 3/29AF146-30-11AF146-30-11B—AF116 ... AF146 3-pole contactors55 to 75 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsSECTION E-E 55.5 0.22"90 3.54"19.5 4.96"126 4.96"30 1.18"DDE150 5.91"10 0.39"ESECTION E-E 55.5 2.18"19.5 0.77"126 4.96"90 3.54"150 5.91"30 1.18"DD10 0.39"AF116, AF140, AF146-30-11AF116, AF140, AF146-30-11BAF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps551607516024...6020...601 1AF116-30-11-111SFL427001R11111.75048...130 48...1301 1AF116-30-11-121SFL427001R12111.750100...250 100...2501 1AF116-30-11-131SFL427001R13111.750250...500 250...5001 1AF116-30-11-141SFL427001R14111.7507520010020024...6020...601 1AF140-30-11-111SFL447001R11111.75048...130 48...1301 1AF140-30-11-121SFL447001R12111.750100...250 100...2501 1AF140-30-11-131SFL447001R13111.750250...500 250...5001 1AF140-30-11-141SFL447001R14111.7507522510020024...6020...601 1AF146-30-11-111SFL467001R11111.75048...130 48...1301 1AF146-30-11-121SFL467001R12111.750100...250 100...2501 1AF146-30-11-131SFL467001R13111.750250...500 250...5001 1AF146-30-11-141SFL467001R14111.750With bar connections551607516024...6020...601 1AF116-30-11B-11 1SFL427002R11111.50048...130 48...1301 1AF116-30-11B-121SFL427002R12111.500100...250 100...2501 1AF116-30-11B-131SFL427002R13111.500250...500 250...5001 1AF116-30-11B-141SFL427002R14111.5007520010020024...6020...601 1AF140-30-11B-111SFL447002R11111.50048...130 48...1301 1AF140-30-11B-121SFL447002R12111.500100...250 100...2501 1AF140-30-11B-131SFL447002R13111.500250...500 250...5001 1AF140-30-11B-141SFL447002R14111.5007522510020024...6020...601 1AF146-30-11B-111SFL467002R11111.50048...130 48...1301 1AF146-30-11B-121SFL467002R12111.500100...250 100...2501 1AF146-30-11B-131SFL467002R13111.500250...500 250...5001 1AF146-30-11B-141SFL467002R14111.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.Main dimensions mm, inches1SFC101266V00011SFC101263V000103
1SFC101166C0201 - Rev. A3/30ABB MOTOR PROTECTION AND CONTROLAF146-30-11AF146-30-11B—AF116 ... AF146 3-pole contactors with built-in PLC interface55 to 75 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts for faster opening utilization55.5 0.22"90 3.54"19.5 4.96"30 1.18"DDE150 5.91"10 0.39"142.5 5.61"E55.5 2.18"19.5 0.77"142.5 5.61"90 3.54"150 5.91"30 1.18"DD10 0.39"AF116, AF140, AF146-30-11AF116, AF140, AF146-30-11BAF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps5516075160100...250 100...2501 1AF116-30-11-331SFL427001R33111.750250...500 250...5001 1AF116-30-11-341SFL427001R34111.75075200100200100...250 100...2501 1AF140-30-11-331SFL447001R33111.750250...500 250...5001 1AF140-30-11-341SFL447001R34111.75075225100200100...250 100...2501 1AF146-30-11-331SFL467001R33111.750250...500 250...5001 1AF146-30-11-341SFL467001R34111.750With bar connections5516075160100...250 100...2501 1AF116-30-11B-331SFL427002R33111.500250...500 250...5001 1AF116-30-11B-341SFL427002R34111.50075200100200100...250 100...2501 1AF140-30-11B-331SFL447002R33111.500250...500 250...5001 1AF140-30-11B-341SFL447002R34111.50075225100200100...250 100...2501 1AF146-30-11B-331SFL467002R33111.500250...500 250...5001 1AF146-30-11B-341SFL467002R34111.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.Control inputsMain dimensions mm, inches1SFC101261V00011SFC101258V000103
1SFC101091C0201 - Rev. E ABB MOTOR PROTECTION AND CONTROL 3/311SFC101013V0001AF205-30-111SFC101018V0001AF370-30-11—AF190 ... AF370 3-pole contactors90 to 200 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsB105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"152 5.98"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"AF190, AF205AF265, AF305, AF370AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and up to 340 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg9027512525024...6020...601 1AF190-30-11-111SFL487002R11113.00048...130 48...1301 1AF190-30-11-121SFL487002R12113.000100...250 100...2501 1AF190-30-11-131SFL487002R13113.000250...500 250...5001 1AF190-30-11-141SFL487002R14113.00011035015030024...6020...601 1AF205-30-11-111SFL527002R11113.00048...130 48...1301 1AF205-30-11-121SFL527002R12113.000100...250 100...2501 1AF205-30-11-131SFL527002R13113.000250...500 250...5001 1AF205-30-11-141SFL527002R14113.00013240020035024...6020...601 1AF265-30-11-111SFL547002R11114.64048...130 48...1301 1AF265-30-11-121SFL547002R12114.640100...250 100...2501 1AF265-30-11-131SFL547002R13114.640250...500 250...5001 1AF265-30-11-141SFL547002R14114.64016050025040024...6020...601 1AF305-30-11-111SFL587002R11114.64048...130 48...1301 1AF305-30-11-121SFL587002R12114.640100...250 100...2501 1AF305-30-11-131SFL587002R13114.640250...500 250...5001 1AF305-30-11-141SFL587002R14114.64020060030052024...6020...601 1AF370-30-11-111SFL607002R11114.64048...130 48...1301 1AF370-30-11-121SFL607002R12114.640100...250 100...2501 1AF370-30-11-131SFL607002R13114.640250...500 250...5001 1AF370-30-11-141SFL607002R14114.640(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.Main dimensions mm, inches03
1SFC101167C0201 - Rev. A3/32ABB MOTOR PROTECTION AND CONTROL1SFC101165V0001AF205-30-111SFC101133V0001AF370-30-11—AF190 ... AF370 3-pole contactors with built-in PLC interface90 to 200 kWAC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts for faster opening utilizationB105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 169.5 6.67"140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"195.5 7.70"AF190, AF205AF265, AF305, AF370AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and up to 340 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg90275125250100...250 100...2501 1AF190-30-11-331SFL487002R33113.000250...500 250...5001 1AF190-30-11-341SFL487002R34113.000110350150300100...250 100...2501 1AF205-30-11-331SFL527002R33113.000250...500 250...5001 1AF205-30-11-341SFL527002R34113.000132400200350100...250 100...2501 1AF265-30-11-331SFL547002R33114.640250...500 250...5001 1AF265-30-11-341SFL547002R34114.640160500250400100...250 100...2501 1AF305-30-11-331SFL587002R33114.640250...500 250...5001 1AF305-30-11-341SFL587002R34114.640200600300520100...250 100...2501 1AF370-30-11-331SFL607002R33114.640250...500 250...5001 1AF370-30-11-341SFL607002R34114.640(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.Control inputsMain dimensions mm, inches03
—AF116 ... AF370 3-pole contactors with 1 N.O. + 1 N.C. auxiliary contactsContactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Auxiliary contact blocksMechanical interlock units(between two contactors)CAL19-11 (3)CAL19-11B (3)AF116 ... AF3703 01 11 x CAL19-11+ 2 x CAL19-11B–AF116 ... AF3703 01 1–+ 2 x CAL19-11B (1)+ VM... (2)(1) Total number of auxiliary contact blocks for the two contactors. (2) Interlock type, according to the contactor ratings (see "Accessories").(3) The CEL19 auxiliary contact blocks can replace the CAL19-11 and CAL19-11B. Though, no auxiliary contact block can be mounted outside the CEL19.Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relaysAF116 ... AF140TF140DU (66...142 A)EF146 (54...150 A)AF146–EF146 (54...150 A)AF190, AF205TA200DU (66...200 A)EF205 (63...210 A)AF265 ... AF370–EF370 (115...380 A)The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.(1) Direct mounting - No kit required.AF contactorwith bar connectionsCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockVM Mechanical interlockLT Terminal shroudAF contactorwith built-in cable clampsT F/ TA Thermal overload relay EFElectronic overload relay1SFC101132C0201- Rev. A ABB MOTOR PROTECTION AND CONTROL 3/3303
3/34ABB MOTOR PROTECTION AND CONTROL—AF400 ... AF750 3-pole contactors200 to 400 kW AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC or 600 V DC (2). These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide controlvoltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °C690 VAC-1kWAhpAV 50/60 HzV DCkg200600350550-24...601 1AF400-30-111SFL577001R6811 (1)12.00048...130 48...1301 1AF400-30-111SFL577001R691112.000100...250 100...2501 1AF400-30-111SFL577001R701112.000250...500 250...5001 1AF400-30-111SFL577001R711112.000250700400650-24...601 1AF460-30-111SFL597001R6811 (1)12.00048...130 48...1301 1AF460-30-111SFL597001R691112.000100...250 100...2501 1AF460-30-111SFL597001R701112.000250...500 250...5001 1AF460-30-111SFL597001R711112.000315800500750-24...601 1AF580-30-111SFL617001R6811 (1)15.00048...130 48...1301 1AF580-30-111SFL617001R691115.000100...250 100...2501 1AF580-30-111SFL617001R701115.000250...500 250...5001 1AF580-30-111SFL617001R711115.0004001050600900-24...601 1AF750-30-111SFL637001R6811 (1)15.00048...130 48...1301 1AF750-30-111SFL637001R691115.000100...250 100...2501 1AF750-30-111SFL637001R701115.000250...500 250...5001 1AF750-30-111SFL637001R711115.000(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the nega-tive pole.(2) Up to 850 V DC for AF580, AF750.AF400 ... AF750 are equipped with low voltage inputs for control, for example by a PLC.Control inputs1SFC101022V0001AF460-30-111SFC101025V0001AF750-30-1163 2.48"186 7.32"25 0.98"22.5 0.89"11.5 0.45"268 10.55"ø 10.5 0.41"ø 6.5 0.26"216 8.5"48.5 1.91"6 0.24"278 10.94"72 2.83"210 8.27"40 1.57"22.5 0.89"11.5 0.45"273 10.75"ø12.5 0.49"ø6.5 0.26"242 9.53"48.5 1.91"6 0.24"283 11.14"AF400, AF460AF580, AF750Main dimensions mm, inches1SFC101013C0201 - Rev. A03
1SFC101094C0201 - Rev. BAF1250 ... AF2850 are equipped with low voltage inputs for control, for example by a PLCControl inputsAF1350, AF1650, AF2050 AF2650, AF2850A392 mm / 15.43"422 mm / 16.61"B47 mm / 1.85"53 mm / 2.09"C10 mm / 0.39"25 mm / 0.98"—AF1250 ... AF2850 3-pole contactors 475 to 560 kW and 1260 to 2850 A AC-1 AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC, AF2650 and AF2850 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main poles. – control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range(e.g. 100...250 V AC and DC) - only 4 coils for AF1250 to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC - only 1 coil for AF1350 ... AF2850 to cover control voltages between 100...250 V 50/60 Hz and 100...250 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(2)power400 VAC-3currentθ ≤ 40 °C690 VAC-1kWAhpAV 50/60 HzV DCkg-1260-1210-24...601 1AF1250-30-111SFL647001R6811 (1)16.00048...130 48...1301 1AF1250-30-111SFL647001R691116.000100...250 100...2501 1AF1250-30-111SFL647001R701116.000250...500 250...5001 1AF1250-30-111SFL647001R711116.00047513508001350100...250 100...2501 1AF1350-30-111SFL657001R701134.00056016509001650100...250 100...2501 1AF1650-30-111SFL677001R701135.000-2050-2100100...250 100...2501 1AF2050-30-111SFL707001R701135.000-2650-2700100...250 100...2501 1AF2650-30-111SFL667001R701145.000-2850-2850100...250 100...2501 1AF2850-30-111SFL687001R701145.000(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.(2) AF2650: Maximum operational voltage = 1000 V according to UL / CSA.50 1.97"72 2.83"72 2.83"210 8.27"344 13.54"313 12.32"263 10.35"72 2.83"ø 7 0.28"ø7 0.28"27 249 9.8"242 9.53"46.58 0.31"18.3"401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"40 1.57"AF2650, AF2850401.57"40 1.57"17 0.67"ø 130.51"136 5.35"136 5.35"80 136 5.35"ø 9 0.35"B 438 17.24"A312 12.3"C244 9.61"3.15"101 3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050AF1250AF1350, AF1650, AF2050, AF2650, AF2850AF1250-30-111SFC101027V00011SFC101031V0001AF2650-30-11Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 3/3503
1SFC101076D0201 - Rev. A—AF1350T ... AF2850T 3-pole contactors with built-in LVRT475 to 560 kW and 1350 to 2850 A AC-1AC operated with 1 N.O. + 1 N.C. auxiliary contactsAF1350T .. AF2850T contactors are designed to meet the Low Voltage Ride Through requirements for grid connections withstand voltage drop-outs up to 1 sec without opening. These contactors are often used in grid connected applications where the demand of non interrupted power is re-quired. When controlled through built-in PLC connection the contactor is operated directly with-out delay function.•Control circuit: AC or DC operated with electronic coil interface - can withstand voltage drop-outs according to Low Voltage Ride Through requirements - equipped with low voltage inputs for direct control by a PLC - distinct closing and opening - add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUcAuxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °C690 VAC-1kWAhpAV 50/60 Hzkg47513508001350220 ... 2401 1AF1350T-30-11 (1)1SFL657001R910134.00056016509001650220 ... 2401 1 AF1650T-30-11 (1)1SFL677001R910135.000-2050-2100220 ... 2401 1 AF2050T-30-11 (1)1SFL707001R910135.000-2650-2700220 ... 2401 1 AF2650T-30-11 (1)1SFL667001R910145.000-2850-2850220 ... 2401 1 AF2850T-30-11 (1)1SFL687001R910145.000(1) Types -00 and -22 on request.401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"40 1.57"AF2650, AF2850401.57"40 1.57"17 0.67"ø 130.51"136 5.35"136 5.35"80 136 5.35"ø 9 0.35"B 438 17.24"A312 12.3"C244 9.61"3.15"101 3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050AF1350T-30-11, AF1650T-30-11, AF2050T-30-11, AF2650T-30-11, AF2850T-30-10-111SFC101216V0001AF2650-30T-11Control inputsAF1350, AF1650, AF2050 AF2650, AF2850A392 mm / 15.43"422 mm / 16.61"B47 mm / 1.85"53 mm / 2.09"C10 mm / 0.39"25 mm / 0.98"Main dimensions mm, inches3/36ABB MOTOR PROTECTION AND CONTROL03
ABB MOTOR PROTECTION AND CONTROL 3/37—AF400 ... AF2850 3-pole contactors with 1 N.O. + 1 N.C. auxiliary contacts Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Mechanical interlock units(between two contactors)Auxiliary contact blocksCAL18-11CAL18-11B (3)Contactors + auxiliary contact blocksAF400 ... AF28503 01 11 x CAL18-11+ 2 x CAL18-11B–Contactors with mechanical interlocking + auxiliary contact blocksAF400 ... AF28503 01 12 x CAL18-11 (1)+ 4 x CAL18-11B (1)+ VM...H (2)(1) Total number of auxiliary contact blocks for the two contactors. (2) Interlock type, according to the contactor ratings (see "Accessories").(3) The CEL18-.. auxiliary contact blocks can replace the CAL18-11 and CAL18-11B. Though, no auxiliary contact block can be mounted outside the CEL18-..Main accessories (other accessories available)Overload relays fitting detailsContactor typesThermal overload relaysElectronic overload relaysAF400, AF460–EF460 (150...500 A) (1)AF580, AF750–EF750 (250...800 A) (1)AF1350, AF1650–EF1250DU (375...1250 A) (1)The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.(1) Mounting kit required (see "Motor protection").AF contactorCAL18-11B2-pole auxiliarycontact blockCAL18-11B2-pole auxiliarycontact blockVMMechanical blockLT Terminal shroudLW Te rmi n al enlargement1SFC101126C0201 - Rev. B03
1SBC101373S0201 - Rev. D3/38ABB MOTOR PROTECTION AND CONTROL45 1.77"80 3.15"6 0.24"119.5 4.70"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"1SBC101002V0014AF09-30-221SBC101004V0014AF26-30-22—AF09 ... AF38 3-pole contactors 4 to 18.5 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):•2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening.•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc min. ... Uc max.AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg42552524...6020...60 (1)2 2AF09-30-22-11 1SBL137001R11220.32048...130 48...1302 2AF09-30-22-12 1SBL137001R12220.320100...250 100...2502 2AF09-30-22-13 1SBL137001R13220.320250...500 250...5002 2AF09-30-22-14 1SBL137001R14220.3605.5287.52824...6020...60 (1)2 2AF12-30-22-111SBL157001R11220.32048...130 48...1302 2AF12-30-22-121SBL157001R12220.320100...250 100...2502 2AF12-30-22-13 1SBL157001R13220.320250...500 250...5002 2AF12-30-22-141SBL157001R14220.3607.530103024...6020...60 (1)2 2AF16-30-22-111SBL177001R11220.32048...130 48...1302 2AF16-30-22-121SBL177001R12220.320100...250 100...2502 2AF16-30-22-13 1SBL177001R13220.320250...500 250...5002 2AF16-30-22-141SBL177001R14220.3601145154524...6020...60 (1)2 2AF26-30-22-111SBL237001R11220.36048...130 48...1302 2AF26-30-22-121SBL237001R12220.360100...250 100...2502 2AF26-30-22-13 1SBL237001R13220.360250...500 250...5002 2AF26-30-22-141SBL237001R14220.4001550205024...6020...60 (1)2 2AF30-30-22-111SBL277001R11220.36048...130 48...1302 2AF30-30-22-121SBL277001R12220.360100...250 100...2502 2AF30-30-22-13 1SBL277001R13220.360250...500 250...5002 2AF30-30-22-141SBL277001R14220.40018.550255024...6020...60 (1)2 2AF38-30-22-11 1SBL297001R11220.36048...130 48...1302 2AF38-30-22-12 1SBL297001R12220.360100...250 100...2502 2AF38-30-22-13 1SBL297001R13220.360250...500 250...5002 2AF38-30-22-14 1SBL297001R14220.400(1) AF..-30-..-11 not suitable for direct control by PLC-output.Main dimensions mm, inches35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"AF09, AF12, AF16AF26, AF30, AF3803
1SBC101374S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39—AF09Z ... AF38Z 3-pole contactors 4 to 18.5 kWAC / DC operated for specific applications with 2 N.O. + 2 N.C. auxiliary contactsAF09Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):• 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC - can manage large control voltage variations, -allow direct control by PLC-output ≥ 24 V DC 500 mA, - reduced panel energy consumption, - very distinct closing and opening, - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc min. ... Uc max.AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg425525-12...202 2AF09Z-30-22-201SBL136001R20220.36024...6020...602 2AF09Z-30-22-211SBL136001R21220.36048...13048...1302 2AF09Z-30-22-221SBL136001R22220.360100...250 100...2502 2AF09Z-30-22-231SBL136001R23220.3605.5287.528-12...202 2AF12Z-30-22-201SBL156001R20220.36024...6020...602 2AF12Z-30-22-211SBL156001R21220.36048...13048...1302 2AF12Z-30-22-221SBL156001R22220.360100...250 100...2502 2AF12Z-30-22-231SBL156001R23220.3607.5301030-12...202 2AF16Z-30-22-201SBL176001R20220.36024...6020...602 2AF16Z-30-22-211SBL176001R21220.36048...13048...1302 2AF16Z-30-22-221SBL176001R22220.360100...250 100...2502 2AF16Z-30-22-231SBL176001R23220.36011451545-12...202 2AF26Z-30-22-201SBL236001R20220.40024...6020...602 2AF26Z-30-22-211SBL236001R21220.40048...13048...1302 2AF26Z-30-22-22 1SBL236001R22220.400100...250 100...2502 2AF26Z-30-22-231SBL236001R23220.40015502050-12...202 2AF30Z-30-22-201SBL276001R20220.40024...6020...602 2AF30Z-30-22-211SBL276001R21220.40048...13048...1302 2AF30Z-30-22-221SBL276001R22220.400100...250 100...2502 2AF30Z-30-22-231SBL276001R23220.40018.5502550-12...202 2AF38Z-30-22-201SBL296001R20220.40024...6020...602 2AF38Z-30-22-211SBL296001R21220.40048...13048...1302 2AF38Z-30-22-221SBL296001R22220.400100...250 100...2502 2AF38Z-30-22-231SBL296001R23220.400Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole1SBC101002V0014AF09Z-30 - 221SBC101004V0014AF26Z-30-2235 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"AF09Z, AF12Z, AF16Z45 1.77"80 3.15"6 0.24"119.5 4.70"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AF26Z, AF30Z, AF38ZMain dimensions mm, inches03
1SBC101742S0201 - Rev. A3/4 0ABB MOTOR PROTECTION AND CONTROL—AF40 ... AF96 3-pole contactors 18.5 to 30 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack): •2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts •control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phasemotor rating 480 VGeneral use rating 600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg18.570306024...6020...60(1)2 2AF40-30-22-111SBL347001R11221.02048...13048...1302 2AF40-30-22-121SBL347001R12221.020100...250 100...2502 2AF40-30-22-13 1SBL347001R13221.000250...500 250...5002 2AF40-30-22-141SBL347001R14221.00022100408024...6020...60(1)2 2AF52-30-22-111SBL367001R11221.02048...13048...1302 2AF52-30-22-121SBL367001R12221.020100...250 100...2502 2AF52-30-22-13 1SBL367001R13221.000250...500 250...5002 2AF52-30-22-141SBL367001R14221.00030105509024...6020...60(1)2 2AF65-30-22-111SBL387001R11221.02048...13048...1302 2AF65-30-22-121SBL387001R12221.020100...250 100...2502 2AF65-30-22-13 1SBL387001R13221.000250...500 250...5002 2AF65-30-22-141SBL387001R14221.000371256010524...6020...60(1)2 2AF80-30-22-11 1SBL397001R11221.27048...13048...1302 2AF80-30-22-12 1SBL397001R12221.270100...250 100...2502 2AF80-30-22-13 1SBL397001R13221.220250...500 250...5002 2AF80-30-22-14 1SBL397001R14221.220451306011524...6020...60(1)2 2AF96-30-22-111SBL407001R11221.27048...13048...1302 2AF96-30-22-121SBL407001R12221.270100...250 100...2502 2AF96-30-22-13 1SBL407001R13221.220250...500 250...5002 2AF96-30-22-141SBL407001R14221.220(1) For control by PLC-output, use R A4 interface relay.1SBC101006V0014AF40-30-221SBC101007V0014AF80-30-22111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69"111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69" AF40, AF52, AF65-30-22-..43 1.69"6 0.24"119.5 4.70"70 2.76"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607155.5 0.22"43 1.69"6 0.24"119.5 4.70"70 2.76"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607155.5 0.22"AF80, AF96-30-22-..Main dimensions mm, inches03
1SBC100494S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/41—AF09 ... AF96 3-pole contactors with 2 N.O. + 2 N.C. auxiliary contactsContactors and main accessoriesAF contactorCAL4-112-pole auxiliarycontact blockTFEFOverload relayMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMain polesBuilt-in auxiliary contactsSide-mounted accessories Mechanical interlock unit(between 2 contactors)Auxiliary contact blocks2-pole CAL4-11Left sideRight sideVM..AF09 ... AF383 02 21+1or 1AF40 ... AF963 02 21+1or 1–+1+ 1Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relays AF09 ... AF38TF42 (0.10...38 A)EF19 (0.10...19 A)AF26 ... AF38TF42 (0.10...38 A)EF45 (9...45 A)AF40 ... AF65TF65 (22...67 A)EF65 (20...70 A)AF80 , AF96TF96 (40...96 A)EF96 (36...100 A)The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(1) Direct mounting - No kit required.BX4-CAProtective cover03
1SFC101092C0201 - Rev. D3/4 2ABB MOTOR PROTECTION AND CONTROL1SFC101009V0001AF146-30-221SFC101010V0001AF146-30-22B—AF116 ... AF146 3-pole contactors55 to 75 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps551607516024...6020...602 2AF116-30-22-111SFL427001R11221.75048...130 48...1302 2AF116-30-22-121SFL427001R12221.750100...250 100...2502 2AF116-30-22-13 1SFL427001R13221.750250...500 250...5002 2AF116-30-22-141SFL427001R14221.7507520010020024...6020...602 2AF140-30-22-111SFL447001R11221.75048...130 48...1302 2AF140-30-22-121SFL447001R12221.750100...250 100...2502 2AF140-30-22-13 1SFL447001R13221.750250...500 250...5002 2AF140-30-22-131SFL447001R14221.7507522510020024...6020...602 2AF146-30-22-111SFL467001R11221.75048...130 48...1302 2AF146-30-22-121SFL467001R12221.750100...250 100...2502 2AF146-30-22-13 1SFL467001R13221.750250...500 250...5002 2AF146-30-22-141SFL467001R14221.750With bar connections551607516024...6020...602 2AF116-30-22B-111SFL427002R11221.50048...130 48...1302 2AF116-30-22B-121SFL427002R12221.500100...250 100...2502 2AF116-30-22B-13 1SFL427002R13221.500250...500 250...5002 2AF116-30-22B-141SFL427002R14221.5007520010020024...6020...602 2AF140-30-22B-111SFL447002R11221.50048...130 48...1302 2AF140-30-22B-121SFL447002R12221.500100...250 100...2502 2AF140-30-22B-13 1SFL447002R13221.500250...500 250...5002 2AF140-30-22B-141SFL447002R14221.5007522510020024...6020...602 2AF146-30-22B-111SFL467002R11221.50048...130 48...1302 2AF146-30-22B-121SFL467002R12221.500100...250 100...2502 2AF146-30-22B-13 1SFL467002R13221.500250...500 250...5002 2AF146-30-22B-141SFL467002R14221.500(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.SECTION E-E 55.5 0.22"90 3.54"19.5 4.96"126 4.96"30 1.18"DDE150 5.91"10 0.39"ESECTION E-E 55.5 2.18"19.5 0.77"126 4.96"90 3.54"150 5.91"30 1.18"DD10 0.39"AF116, AF140, AF146-30-22AF116, AF140, AF146-30-22BMain dimensions mm, inches03
1SFC101168C0201 ABB MOTOR PROTECTION AND CONTROL 3/431SFC101168C0201 - Rev. A1SFC101184V0001AF146-30-221SFC101187V0001AF146-30-22B—AF116 ... AF146 3-pole contactors with built-in PLC interface55 to 75 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts for faster opening utilizationAF116 ... AF146 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC and AF116 ... AF146 up to 260 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkgFor connection with built-in cable clamps5516075160100...250 100...2502 2AF116-30-22-331SFL427001R33221.750250...500 250...5002 2AF116-30-22-341SFL427001R34221.75075200100200100...250 100...2502 2AF140-30-22-331SFL447001R33221.750250...500 250...5002 2AF140-30-22-341SFL447001R34221.75075225100200100...250 100...2502 2AF146-30-22-331SFL467001R33221.750250...500 250...5002 2AF146-30-22-341SFL467001R34221.750With bar connections5516075160100...250 100...2502 2AF116-30-22B-331SFL427002R33221.500250...500 250...5002 2AF116-30-22B-341SFL427002R34221.50075200100200100...250 100...2502 2AF140-30-22B-331SFL447002R33221.500250...500 250...5002 2AF140-30-22B-341SFL447002R34221.50075225100200100...250 100...2502 2AF146-30-22B-331SFL467002R33221.500250...500 250...5002 2AF146-30-22B-341SFL467002R34221.500For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.Control inputs55.5 0.22"90 3.54"19.5 4.96"30 1.18"DD150 5.91"10 0.39"142.5 5.61"E55.5 2.18"19.5 0.77"142.5 5.61"90 3.54"150 5.91"30 1.18"DD10 0.39"AF116, AF140, AF146-30-22AF116, AF140, AF146-30-22BMain dimensions mm, inches03
1SFC101093C0201 - Rev. E3/4 4ABB MOTOR PROTECTION AND CONTROLAF205-30-22AF370-30-22—AF190 ... AF370 3-pole contactors90 to 200 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and up to 340 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).•built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg9027512525024...6020...602 2AF190-30-22-111SFL487002R11223.00048...130 48...1302 2AF190-30-22-121SFL487002R12223.000100...250 100...2502 2AF190-30-22-13 1SFL487002R13223.000250...500 250...5002 2AF190-30-22-141SFL487002R14223.00011035015030024...6020...602 2AF205-30-22-111SFL527002R11223.00048...130 48...1302 2AF205-30-22-121SFL527002R12223.000100...250 100...2502 2AF205-30-22-13 1SFL527002R13223.000250...500 250...5002 2AF205-30-22-141SFL527002R14223.00013240020035024...6020...602 2AF265-30-22-111SFL547002R11224.67548...130 48...1302 2AF265-30-22-121SFL547002R12224.675100...250 100...2502 2AF265-30-22-13 1SFL547002R13224.675250...500 250...5002 2AF265-30-22-141SFL547002R14224.67516050025040024...6020...602 2AF305-30-22-111SFL587002R11224.67548...130 48...1302 2AF305-30-22-121SFL587002R12224.675100...250 100...2502 2AF305-30-22-13 1SFL587002R13224.675250...500 250...5002 2AF305-30-22-141SFL587002R14224.67520060030052024...6020...602 2AF370-30-22-111SFL607002R11224.67548...130 48...1302 2AF370-30-22-121SFL607002R12224.675100...250 100...2502 2AF370-30-22-131SFL607002R13224.675250...500 250...5002 2AF370-30-22-141SFL607002R14224.675(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.B105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"152 5.98"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"AF190, AF205AF265, AF305, AF370Main dimensions mm, inches1SFC101256V00011SFC101253V000103
1SFC101169C0201 ABB MOTOR PROTECTION AND CONTROL 3/451SFC101169C0201 - Rev. AAF205-30-22AF370-30-22—AF190 ... AF370 3-pole contactors with built-in PLC interface90 to 200 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts for faster opening utilizationAF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC and up to 340 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and 100...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request) - opening time below 20 ms.• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V AC(1)power400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50/60 HzV DCkg90275125250100...250 100...2502 2AF190-30-22-331SFL487002R33223.000250...500 250...5002 2AF190-30-22-341SFL487002R34223.000110350150300100...250 100...2502 2AF205-30-22-331SFL527002R33223.000250...500 250...5002 2AF205-30-22-341SFL527002R34223.000132400200350100...250 100...2502 2AF265-30-22-331SFL547002R33224.675250...500 250...5002 2AF265-30-22-341SFL547002R34224.675160500250400100...250 100...2502 2AF305-30-22-331SFL587002R33224.675250...500 250...5002 2AF305-30-22-341SFL587002R34224.675200600300520100...250 100...2502 2AF370-30-22-331SFL607002R33224.675250...500 250...5002 2AF370-30-22-341SFL607002R34224.675(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.Control inputsB105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 169.5 6.67"140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"195.5 7.70"AF190, AF205AF265, AF305, AF370Main dimensions mm, inches1SFC101251V00011SFC101248V000103
—AF116 ... AF370 3-pole contactors with 2 N.O. + 2 N.C. auxiliary contacts Main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Mechanical interlock units(between two contactors)Auxiliary contact blocksCAL19-11 (2)CAL19-11B (2)AF116 ... AF3703 02 22 x CAL19-11 included+ 2 x CAL19-11B–(2) The CEL19 auxiliary contact blocks can replace the CAL19-11 and CAL19-11B. Though, no auxiliary contact block can be mounted outside the CEL19.Main accessories (other accessories available)Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relaysAF116 ... AF140TF140DU (66...142 A)EF146 (54...150 A)AF146–EF146 (54...150 A)AF190, AF205TA200DU (66...200 A)EF205 (63...210 A)AF265 ... AF370–EF370 (115...380 A)The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.(1) Direct mounting - No kit required.CAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockT F/ TA Thermal overload relay EFElectronic overload relayAF contactorwith built-in cable clampsLW Te rmi n al enlargement3/4 6ABB MOTOR PROTECTION AND CONTROL1SFC101133C0201 - Rev. B03
1SFC101014C0201 - Rev. A—AF400 ... AF750 3-pole contactors200 to 400 kW AC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC or 600 V DC (2). These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUcAuxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phase motor rating480 VGeneral use rating600 V ACpower400 VAC-3currentθ ≤ 40 °C690 VAC-1kWAhpAV 50/60 HzV DCkg200600350550-24...602 2AF400-30-221SFL577001R6822 (1)12.00048...130 48...1302 2AF400-30-221SFL577001R692212.000100...250 100...2502 2AF400-30-221SFL577001R702212.000250...500 250...5002 2AF400-30-221SFL577001R712212.000250700400650-24...602 2AF460-30-221SFL597001R6822 (1)12.00048...130 48...1302 2AF460-30-221SFL597001R692212.000100...250 100...2502 2AF460-30-221SFL597001R702212.000250...500 250...5002 2AF460-30-221SFL597001R712212.000315800500750-24...602 2AF580-30-221SFL617001R6822 (1)15.00048...130 48...1302 2AF580-30-221SFL617001R692215.000100...250 100...2502 2AF580-30-221SFL617001R702215.000250...500 250...5002 2AF580-30-221SFL617001R712215.0004001050600900-24...602 2AF750-30-221SFL637001R6822 (1)15.00048...130 48...1302 2AF750-30-221SFL637001R692215.000100...250 100...2502 2AF750-30-221SFL637001R702215.000250...500 250...5002 2AF750-30-221SFL637001R712215.000(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.(2) Up to 850 V DC for AF580, AF750.AF400...AF750 are equipped with low voltage inputs for control, for example by a PLC.Control inputs63 2.48"186 7.32"25 22.5 11.5 0.45"268 10.55"ø10.5 0.41"ø6.5 0.26"0.98"0.89"216 8.5"48.5 1.91"6 0.24"278 10.94"72 2.83"210 8.27"401.57"22.5 11.5 0.45"273 10.75"ø12.50.49"ø6.50.26"0.89"242 9.53"48.5 1.91"6 0.24"283 11.14"AF400, AF460AF580, AF7501SFC101081V0001AF460-30-221SFC101091V0001AF750-30-22Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 3/4703
1SFC101095C0201 - Rev. A—AF1250 ... AF2850 3-pole contactors 475 to 560 kW and 1260 to 2850 A AC-1 AC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC, AF2650 and AF2850 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC)•only 4 coils for AF1250 to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC•only 1 coil for AF1350 ... AF2850 to cover control voltages between 100...250 V 50/60 Hz and 100...250 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).•built-in surge suppression• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotor rating480 VGeneral use rating600 V AC(2)power400 VAC-3currentθ ≤ 40 °C690 VAC-1kWAhpAV 50/60 HzV DCkg-1260-1210-24...602 2AF1250-30-221SFL647001R6822 (1)16.00048...130 48...1302 2AF1250-30-221SFL647001R692216.000100...250 100...2502 2AF1250-30-221SFL647001R702216.000250...500 250...5002 2AF1250-30-221SFL647001R712216.00047513508001350100...250 100...2502 2AF1350-30-221SFL657001R702234.00056016509001650100...250 100...2502 2AF1650-30-221SFL677001R702235.000-2050-2100100...250 100...2502 2AF2050-30-221SFL707001R702235.000-2650-2700100...250 100...2502 2AF2650-30-221SFL667001R702245.000-2850-2850100...250 100...2502 2AF2850-30-221SFL687001R702245.000(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2for the negative pole.(2) AF2650 : Maximum operational voltage = 1000 V according to UL / CSA.AF1250-30-221SFC101092V00011SFC101032V0001AF2650-30-2250 1.97"72 2.83"72 2.83"210 8.27"344 13.54"313 12.32"263 10.35"72 2.83"ø 7 0.28"ø7 0.28"27 249 9.8"242 9.53"46.58 0.31"18.3"401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"40 1.57"AF2650, AF2850401.57"40 1.57"17 0.67"ø 130.51"136 5.35"136 5.35"80 136 5.35"ø 9 0.35"B 438 17.24"A312 12.3"C244 9.61"3.15"101 3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050AF1250AF1350, AF1650, AF2050, AF2650, AF2850AF1250 ... AF2850 are equipped with low voltage inputs for control, for example by a PLC.Control inputsAF1350, AF1650, AF2050AF2650, AF2850A392 mm / 15.43"422 mm / 16.61"B47 mm / 1.85"53 mm / 2.11"C10 mm / 0.39"25 mm / 0.98"Main dimensions mm, inches3/4 8ABB MOTOR PROTECTION AND CONTROL03
1SFC101127C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/49—AF400... AF2850 3-pole contactors with 2 N.O. + 2 N.C. auxiliary contacts Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Auxiliary contact blocksMechanical interlock units(between two contactors)CAL18-11CAL18-11B (2)Contactors + auxiliary contact blocksAF145 ... AF28503 02 22 x CAL18-11 included2 x CAL18-11B–Contactors with mechanical interlocking + auxiliary contact blocksAF400 ... AF28503 02 22 x CAL18-11 included4 x CAL18-11B+ VM...H (1)(1) Interlock type, according to the contactor ratings (see "Accessories").(2) The CEL18-.. auxiliary contact blocks can replace the CAL18-11 and CAL18-11B. Though, no auxiliary contact block can be mounted outside the CEL18-..Overload relays fitting detailsContactor typesThermal overload relaysElectronic overload relaysAF400, AF460–EF460 (150...500 A) (3)AF580, AF750–EF750 (250...800 A) (3)AF1350, AF1650–E1250DU (375...1250 A) (3)The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.(3) Mounting kit required (see "Motor protection").CAL18-11B2-pole auxiliarycontact blockCAL18-11B2-pole auxiliarycontact blockVMMechanical blockLT Terminal shroudLW Te rmi n al enlargement03
—AF09 ... AF38 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C35 A35 A35 A50 A50 A50 AWith conductor cross-sectional area6 mm²6 mm²6 mm²10 mm²10 mm²10 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 25 A28 A30 A45 A50 A50 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 25 A28 A30 A40 A42 A42 Aθ ≤ 70 °C 22 A24 A26 A32 A37 A37 AWith conductor cross-sectional area4 mm²6 mm²6 mm²10 mm²10 mm²10 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 9 A12 A18 A26 A33 A40 A380-400 V 9 A12 A18 A26 A32 A38 A415 V 9 A12 A18 A26 A32 A38 A440 V 9 A12 A18 A26 A32 A38 A500 V 9.5 A12.5 A15 A23 A28 A33 A690 V 7 A9 A10.5 A17 A21 A24 ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 2.2 kW3 kW4 kW6.5 kW9 kW11 kW380-400 V 4 kW5.5 kW7.5 kW11 kW15 kW18.5 kW415 V 4 kW5.5 kW9 kW11 kW15 kW18.5 kW440 V 4 kW5.5 kW9 kW15 kW18.5 kW22 kW500 V 5.5 kW7.5 kW9 kW15 kW18.5 kW22 kW690 V 5.5 kW7.5 kW9 kW15 kW18.5 kW22 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)Ie / Rated operational current AC-8a12 A16 A22 A30 A40 A50 ARated operational power AC-8a5.5 kW7.5 kW11 kW15 kW20 kW25 kWShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse25 A32 A32 A50 A63 A63 ARated short-time withstand current Icw1 s 300 A300 A300 A700 A700 A700 Aat 40 °C ambient temperature,in free air from a cold state10 s 150 A150 A150 A350 A350 A350 A30 s 80 A80 A80 A225 A225 A225 A1 min 60 A60 A60 A150 A150 A150 A15 min 35 A35 A35 A50 A50 A50 AMaximum breaking capacitycos φ = 0.45at 440 V 250 A250 A250 A500 A500 A500 Aat 690 V 106 A106 A106 A200 A200 A200 APower dissipation per poleIe / AC-1 0.8 W1 W1.2 W1.8 W2.4 W2.4 WIe / AC-3 0.1 W0.2 W0.35 W0.6 W0.9 W1.3 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-2, AC-4300 cycles/h150 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".3/50ABB MOTOR PROTECTION AND CONTROL1SBC101425S020103
1SBC101743S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/51Main pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF40AF52AF65AF80AF96StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 V1000 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C105 A105 A105 A130 A130 AWith conductor cross-sectional area35 mm²35 mm²35 mm²50 mm²50 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 70 A100 A105 A125 A130 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 60 A80 A90 A100 A105 Aθ ≤ 70 °C 50 A70 A80 A85 A90 AWith conductor cross-sectional area25 mm²35 mm²35 mm²50 mm²50 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 40 A53 A65 A80 A96 A380-400 V 40 A53 A65 A80 A96 A415 V 40 A53 A65 A80 A96 A440 V 40 A53 A65 A80 A96 A500 V 35 A45 A55 A65 A80 A690 V 25 A35 A39 A49 A57 A1000 V---25 A30ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 11 kW15 kW18.5 kW22 kW25 kW380-400 V 18.5 kW22 kW30 kW37 kW45 kW415 V 22 kW30 kW37 kW45 kW55 kW440 V 22 kW30 kW37 kW45 kW55 kW500 V 22 kW30 kW37 kW45 kW55 kW690 V 22 kW30 kW37 kW45 kW55 kW1000 V---35 kW40 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category(without thermal overload relay Ue 400 V 50/60 Hz - θ ≤ 40 °C)Ie / Rated operational current AC-8a53 A70 A85 A105 A120 ARated operational power AC-8a25 kW37 kW45 kW55 kW65 kWShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse100 A125 A160 A160 A200 ARated short-time withstand current Icw1 s 1000 A1000 A1000 A1200 A1200 Aat 40 °C ambient temperature,10 s 600 A600 A600 A780 A780 Ain free air from a cold state30 s 350 A350 A350 A450 A450 A1 min 250 A250 A250 A300 A300 A15 min 110 A110 A110 A140 A140 AMaximum breaking capacitycos φ = 0.45at 440 V 950 A950 A950 A1150 A1150 Aat 690 V 600 A600 A600 A750 A750 APower dissipation per poleIe / AC-1 3 W6.3 W7 W7.6 W8.2 WIe / AC-3 1 W1.7 W2.7 W3 W4.5 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-2, AC-4150 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".—AF40 ... AF96 3-pole contactorsTechnical data03
1SFC101108C0201 - Rev. A3/52ABB MOTOR PROTECTION AND CONTROL—AF116 ... AF370 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 V690 V1000 V1000 V1000 V1000 V1000 V1000 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C160 A200 A225 A275 A350 A400 A500 A600 AWith conductor cross-sectional area70 mm²95 mm²95 mm²150 mm²240 mm² (3) 240 mm²300 mm² (4) 2 x 185 mm² (4)AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 160 A200 A225 A275 A350 A400 A500 A600 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 145 A175 A200 A250 A300 A350 A400 A500 Aθ ≤ 70 °C 130 A160 A175 A200 A240 A290 A325 A400 AIe / Rated operational current AC-1θ ≤ 40 °C––225 A250 A275 A350 A375 A400 AUe max. ≤ 1000 V, 50/60 Hzθ ≤ 60 °C––200 A225 A250 A300 A325 A350 Aθ ≤ 70 °C––175 A185 A200 A240 A260 A290 AWith conductor cross-sectional area70 mm²95 mm²95 mm²150 mm²240 mm² (3) 240 mm²300 mm² (4) 2 x 185 mm² (4)AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 116 A140 A146 A190 A205 A265 A305 A370 A380-400 V 116 A140 A146 A190 A205 A265 A305 A370 A415 V 116 A140 A146 A190 A205 A265 A305 A370 A440 V 116 A140 A146 A190 A205 A265 A305 A370 A500 V 110 A130 A130 A156 A186 A250 A290 A350 A690 V 65 A80 A93 A135 A165 A250 A290 A315 A1000 V––60 A85 A100 A113 A131 A141 ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 30 kW37 kW45 kW55 kW55 kW75 kW90 kW110 kW380-400 V 55 kW75 kW75 kW90 kW110 kW132 kW160 kW200 kW415 V 55 kW75 kW75 kW90 kW110 kW132 kW160 kW200 kW440 V 75 kW90 kW90 kW110 kW132 kW160 kW160 kW200 kW500 V 75 kW90 kW90 kW90 kW110 kW200 kW200 kW250 kW690 V 55 kW75 kW90 kW132 kW160 kW200 kW250 kW315 kW1000 V––75 kW110 kW132 kW160 kW185 kW200 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorswithout thermal overload relay - Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse250 A315 A315 A355 A400 A500 A500 A630 ARated short-time withstand current Icw1 s 1300 A1460 A1460 A1900 A2050 A2650 A3050 A3700 Aat 40 °C ambient temperature,10 s 928 A1168 A1168 A1520 A1640 A2120 A2440 A2960 Ain free air from a cold state30 s 536 A674 A674 A878 A947 A1224 A1409 A1709 A1 min 379 A477 A477 A621 A670 A865 A996 A1208 A15 min 160 A200 A225 A275 A350 A400 A500 A600 AMaximum breaking capacitycos φ = 0.45at 440 V 2000 A3000 A3000 A3300 A3500 A3800 A4600 A5000 A(cos φ = 0.35 for Ie > 100 A)at 690 V 1000 A1500 A1500 A2200 A2500 A3300 A3800 A4000 APower dissipation per poleIe / AC-1 12 W18 W23 W15 W25 W32 W50 W72 WIe / AC-3 6 W9 W10 W7 W8 W14 W19 W27 WMaximum electrical switching frequencyAC-1300 cycles/hAC-3300 cycles/hAC-2, AC-4150 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".(3) For currents above 275A use terminal enlargements or terminal extensions.(4) For currents above 450A use terminal enlargements or terminal extensions. 03
1SFC101110C02011SFC101110C0201 - Rev. E—AF400 ... AF750 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF400AF460AF580AF750StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.1000 VRated frequency (without derating)50/60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C600 A700 A800 A1050 AWith conductor cross-sectional area (3)2x185 mm²2x240 mm²2x240 mm²800 mm² (4)AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 600 A700 A800 A1050 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 55 °C 500 A600 A700 A875 Aθ ≤ 70 °C 400 A480 A580 A720 AIe / Rated operational current AC-1θ ≤ 40 °C 600 A700 A800 A1000 AUe max. ≤ 1000 V, 50/60 Hzθ ≤ 55 °C 500 A600 A700 A875 Aθ ≤ 70 °C 400 A480 A580 A720 AWith conductor cross-sectional area2x185 mm²2x240 mm²2x240 mm²800 mm² (4)AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 55 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 400 A460 A580 A750 A380-400 V 400 A460 A580 A750 A415 V 400 A460 A580 A750 A440 V 400 A460 A580 A750 A500 V 400 A460 A580 A750 A690 V 350 A400 A500 A650 A1000 V 155 A200 A250 A300 ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 110 kW132 kW160 kW220 kW380-400 V 200 kW250 kW315 kW400 kW415 V 220 kW250 kW355 kW425 kW440 V 220 kW250 kW355 kW450 kW500 V 250 kW315 kW400 kW520 kW690 V 315 kW355 kW500 kW600 kW1000 V 220 kW280 kW355 kW400 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorswithout thermal overload relayMotor protection excluded (2)Ue ≤ 500 V AC - gG type fuse630 A800 A1000 A1000 ARated short-time withstand current Icw1 s 4600 A4600 A7000 A7000 Aat 40 °C ambient temperature,in free air from a cold state10 s 4400 A4400 A6400 A6400 A30 s 3100 A3100 A4500 A4500 A1 min 2500 A2500 A3500 A3500 A15 min 840 A840 A1300 A1300 AMaximum breaking capacitycos φ = 0.45at 440 V 4000 A5000 A6000 A7500 A(cos φ = 0.35 for Ie > 100 A)at 690 V 3500 A4500 A5000 A7000 APower dissipation per poleIe / AC-1 30 W42 W32 W50 WIe / AC-3 16 W21 W17 W28 WMax. electrical switching frequencyAC-1300 cycles/h300 cycles/hAC-3300 cycles/h300 cycles/hAC-2, AC-460 cycles/h60 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".(3) Conductors with preparation.(4) Max. connection bar width 50 mm.(5) Max. connection bar width 100 mm. ABB MOTOR PROTECTION AND CONTROL 3/5303
1SFC101110C0201 - Rev. E—AF1250 ... AF2850 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.1000 VRated frequency (without derating)50/60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C1260 A1350 A1650 A2050 A2650 A2850 AWith conductor cross-sectional area (3)1000 mm² (4)1000 mm² (5) 1500 mm² (5)2000 mm² (5)3000 mm² (5)3000 mm² (5)AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 1260 A1350 A1650 A2050 A2650 A2850 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 55 °C 1040 A1150 A1450 A1750 A2350 A2600 Aθ ≤ 70 °C 875 A1000 A1270 A1500 A2120 A2300 AIe / Rated operational current AC-1θ ≤ 40 °C 1260 A1350 A1650 A2050 A2650 A2850 AUe max. ≤ 1000 V, 50/60 Hzθ ≤ 55 °C 1040 A1150 A1450 A1750 A2350 A2600 Aθ ≤ 70 °C 875 A1000 A1270 A1500 A2120 A2300 AWith conductor cross-sectional area1000 mm² (4)1000 mm² (5) 1500 mm² (5)2000 mm² (5)3000 mm² (5)3000 mm² (5)AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 55 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V–860 A1060 A1060 A––380-400 V–860 A1060 A1060 A––415 V–860 A1060 A1060 A– – 440 V–860 A1060 A1060 A––500 V–800 A970 A970 A––690 V–800 A970 A970 A––1000 V–375 A400 A425 A––Rated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V–257 kW315 kW–––380-400 V–475 kW560 kW–––415 V–500 kW630 kW630 kW––440 V–560 kW710 kW710 kW––500 V–560 kW710 kW–––690 V–800 kW1000 kW1000 kW––1000 V–560 kW600 kW630 kW––Rated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorswithout thermal overload relayMotor protection excluded (2)Ue ≤ 500 V AC - gG type fusePlease consult us for coordination with circuit-breakerRated short-time withstand current Icw1 s 8000 A10000 A12000 A12000 A12000 A12000 Aat 40 °C ambient temperature,in free air from a cold state10 s 7200 A8000 A10000 A10000 A10000 A10000 A30 s 5200 A6000 A7500 A7500 A 7500 A 7500 A 1 min 4000 A4500 A5500 A5500 A5500 A5500 A15 min 1500 A1600 A2200 A2200 A2800 A3000 AMaximum breaking capacitycos φ = 0.45at 440 V 7500 A10000 A12000 A8400 A8400 A8400 A(cos φ = 0.35 for Ie > 100 A)at 690 V 7000 A–––––Power dissipation per poleIe / AC-1 80 W80 W80 W125 W200 W200 WIe / AC-3–50 W50 W–––Max. electrical switching frequencyAC-1 300 cycles/h60 cycles/h60 cycles/h15 cycles/h15 cycles/hAC-3–60 cycles/h–––AC-2, AC-4–60 cycles/h–––(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".(3) Conductors with preparation.(4) Max. connection bar width 50 mm.(5) Max. connection bar width 100 mm.3/54ABB MOTOR PROTECTION AND CONTROL03
—AF09 ... AF38 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38StandardsUL 508, CSA C22.2 N°60947-4-1Max. operational voltage600 VNEMA size000–1––NEMA continuous amp ratingThermal current9 A18 A27 ANEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 1/3 hp1 hp2 hp230 V AC 1 hp2 hp3 hpNEMA maximum horse power ratings 3-phase, 60 Hz200 V AC 1-1/2 hp3 hp7-1/2 hp230 V AC 1-1/2 hp3 hp7-1/2 hp460 V AC 2 hp5 hp10 hp575 V AC 2 hp5 hp10 hpUL / CSA general use rating600 V AC 25 A28 A30 A45 A50 A50 AWith conductor cross-sectional areaAWG 10AWG 10AWG 10AWG 8AWG 8AWG 81 pole80 V DC 25 A28 A30 A45 A50 A50 A2 poles in serie160 V DC 25 A28 A30 A45 A50 A50 A3 poles in serie240 V DC 25 A28 A30 A45 A50 A50 AWith conductor cross-sectional areaAWG 10AWG 10AWG 10AWG 8AWG 8AWG 8UL / CSA maximum 1-phase motor ratingFull load current120 V AC 13.8 A16 A20 A24 A24 A24 A240 V AC 10 A12 A17 A17 A28 A28 AHorse power rating120 V AC 3/4 hp1 hp1-1/2 hp2 hp2 hp2 hp240 V AC 1-1/2 hp2 hp3 hp3 hp5 hp5 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 7.8 A11 A17.5 A25.3 A32.2 A32.2 A220-240 V AC 6.8 A9.6 A15.2 A22 A28 A28 A440-480 V AC 7.6 A11 A14 A21 A27 A34 A (3)550-600 V AC 9 A11 A17 A22 A27 A (2)32 A (3)Horse power rating (1)200-208 V AC 2 hp3 hp5 hp7-1/2 hp10 hp 10 hp220-240 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp440-480 V AC 5 hp7-1/2 hp10 hp15 hp20 hp25 hp (3)550-600 V AC 7-1/2 hp10 hp15 hp20 hp25 hp (2)30 hp (3)UL / CSA - DC motor starting - 3 poles in seriesFull Load Amps (FLA)125 V DC 9.5 A13.2 A17 A25 A25 A25 A250 V DC 8.5 A12.2 A12.2 A20 A29 A29 AHorse power rating125 V DC 1 hp1-1/2 hp2 hp3 hp3 hp3 hp250 V DC 2 hp3 hp3 hp5 hp7-1/2 hp7-1/2 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedHigh fault current100 kAFuse rating30 A30 A60 A60 A100 A100 AFuse type, 600 VJMax. electrical switching frequencyFor general use600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.(2) For contactors produced since week 49-2011.(3) For contactors produced since week 36-2014. ABB MOTOR PROTECTION AND CONTROL 3/551SBC101426S0201 - Rev. C03
1SBC101744S0201 - Rev. B3/56ABB MOTOR PROTECTION AND CONTROL—AF40 ... AF96 3-pole contactors Technical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF40AF52AF65AF80AF96StandardsUL 60947-4-1, CSA C22.2 N°60947-4-1Maximum operational voltage600 VNEMA size2--3-NEMA continuous amp ratingThermal current45 A--90 A-NEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 3 hp----230 V AC 7.5 hp----NEMA maximum horse power ratings 3-phase, 60 Hz200 V AC 10 hp--25 hp-230 V AC 15 hp--30 hp-460 V AC 25 hp--50 hp-575 V AC 25 hp--50 hp-UL / CSA general use rating600 V AC 60 A80 A90 A105 A115 AWith conductor cross-sectional areaAWG 6AWG 4AWG 3AWG 2AWG 21 pole80 V DC 60 A80 A90 A105 A115 A2 poles in serie160 V DC 60 A80 A90 A105 A115 A3 poles in serie240 V DC 60 A80 A90 A105 A115 AWith conductor cross-sectional areaAWG 6AWG 4AWG 3AWG 2AWG 2UL / CSA maximum 1-phase motor ratingFull load current120 V AC 34 A34 A56 A80 A80 A240 V AC 40 A50 A68 A68 A88 AHorse power rating120 V AC 3 hp3 hp5 hp7-1/2 hp7-1/2 hp240 V AC 7-1/2 hp10 hp15 hp15 hp20 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 32.2 A48.3 A62.1 A78.2 A92 A220-240 V AC 42 A54 A68 A80 A80 A440-480 V AC 40 A52 A65 A77 A77 A550-600 V AC 41 A52 A62 A77 A77 AHorse power rating (1)200-208 V AC 10 hp15 hp20 hp25 hp30 hp220-240 V AC 15 hp20 hp25 hp30 hp30 hp440-480 V AC 30 hp40 hp50 hp60 hp60 hp550-600 V AC 40 hp50 hp60 hp75 hp75 hpUL / CSA - DC motor starting - 3 poles in seriesFull Load Amps (FLA)125 V DC 40 A58 A76 A76 A110 A250 V DC 38 A55 A72 A89 A106 AHorse power rating125 V DC 5 hp7-1/2 hp10 hp10 hp15 hp250 V DC 10 hp15 hp20 hp25 hp30 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedHigh fault current100 kAFuse rating150 A150 A150 A200 A200 AFuse type, 600 VJMaximum electrical switching frequencyFor general use 600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".03
1SFC101109C0201 ABB MOTOR PROTECTION AND CONTROL 3/571SFC101109C0201 - Rev. B—AF116 ... AF370 3-pole contactorsTechnical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370StandardsUL 60947-1 / 60947-4-1A and CSA 60947-1 / 60947-4-1AMaximum operational voltage600VNEMA size–4–––5––NEMA continuous amp ratingThermal current–135 A–––270 A––NEMA maximum horse power ratings 1-phase, 60 Hz115 V AC––––––––230 V AC––––––––NEMA maximum horse power ratings 3-phase, 60 Hz200 V AC–40 hp–––75 hp––230 V AC–50hp–––100 hp––460 V AC–100 hp–––200 hp––575 V AC–100 hp–––200 hp––UL / CSA general use rating600 V AC160 A200 A200 A250 A300 A350 A400 A520 AWith conductor cross-sectional areaAWG 2/0AWG 3/0AWG 3/0MCM 250MCM 350 (2) MCM 5002//AWG 3/0 2//MCM 300UL / CSA maximum 1-phase motor ratingFull load current120 V AC––––––––240 V AC––––––––Horse power rating120 V AC––––––––240 V AC––––––––UL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 92 A120 A120 A150 A177 A221 A285 A359 A220-240 V AC 104 A130 A130 A154 A192 A248 A312 A360 A440-480 V AC 96 A124 A124 A156 A180 A240 A302 A361 A550-600 V AC 99 A125 A125 A144 A192 A242 A289 A336 AHorse power rating (1)200-208 V AC 30 hp40 hp40 hp50 hp60 hp75 hp100 hp125 hp220-240 V AC 40 hp50 hp50 hp60 hp75 hp100 hp125 hp150 hp440-480 V AC 75 hp100 hp100 hp125 hp150 hp200 hp250 hp300 hp550-600 V AC 100 hp125 hp125 hp150 hp200 hp250 hp300 hp350 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedHigh fault current100 kAFuse rating225 A250 A250 A450 A400 A500 A600 A800 AFuse type, 600 VJMaximum electrical switching frequencyFor general use300 cycles/hFor motor use300 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents". (2) For conductor cross-sectional area above MCM 300 use terminal enlargements LW205.03
1SFC101111C0201 - Rev. G3/58ABB MOTOR PROTECTION AND CONTROL—AF400 ... AF750 3-pole contactors Technical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF400AF460AF580AF750StandardsUL 60947-1 / 60947-4-1 and CSA C 22.2 N°60947-1 / 60947-4-1Maximum operational voltage1 000 VNEMA size–6–7NEMA maximum horse power ratings 1-phase, 60 Hz115 V AC–230 V AC–NEMA maximum horse power ratings 3-phase, 60 Hz200 V AC–150 hp––230 V AC–200 hp–300 hp460 V AC–400 hp–600 hp575 V AC–400 hp–600 hpUL / CSA general use rating1000 V AC550 A650 A750 A900 A3 poles in serie600 V DC 550 A650 A750 A900 AUL / CSA maximum 1-phase motor ratingFull load current120 V AC––––240 V AC––––Horse power rating120 V AC––––240 V AC––––UL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 358.8 A414 A552 A692.3 A220-240 V AC 360 A480 A604 A722 A440-480 V AC 414 A477 A590 A722 A550-600 V AC 382 A472 A578 A672 AHorse power rating (1)200-208 V AC 125 hp150 hp200 hp250 hp220-240 V AC 150 hp200 hp250 hp300 hp440-480 V AC 350 hp400 hp500 hp600 hp550-600 V AC 400 hp500 hp600 hp700 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedFuse rating1000 A1200 AFuse type, 600 VLMaximum electrical switching frequencyFor general use300 cycles/hFor motor use300 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.03
1SFC101111C02011SFC101111C0201 - Rev. G ABB MOTOR PROTECTION AND CONTROL 3/59—AF1250 ... AF2850 3-pole contactors Technical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850StandardsUL 60947-1 / 60947-4-1 and CSA C 22.2 N°60947-1 / 60947-4-1Maximum operational voltage1 000 VNEMA size––8–––NEMA maximum horse power ratings 1-phase, 60 Hz115 V AC–230 V AC–NEMA maximum horse power ratings 3-phase, 60 Hz200 V AC––––––230 V AC 300 hp–450 hp–––460 V AC 600 hp–900 hp–––575 V AC 600 hp–900 hp–––UL / CSA general use rating1000 V AC1210 A1350 A1650 A2100 A2700 A2850 A3 poles in serie600 V DC 1210 A–––––UL / CSA maximum 1-phase motor ratingFull load current120 V AC––––––240 V AC––––––Horse power rating120 V AC––––––240 V AC––––––UL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC–954 A1030 A–––220-240 V AC–954 A1030 A–––440-480 V AC–954 A1030 A–––550-600 V AC–944 A1050 A–––Horse power rating (1)200-208 V AC––––––220-240 V AC–400 hp450 hp–––440-480 V AC–800 hp900 hp–––550-600 V AC–1000 hp1150 hp–––Short-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedFuse rating1200 APlease consult us for coordination with circuit-breakerFuse type, 600 VLMaximum electrical switching frequencyFor general use300 cycles/h60 cycles/h15 cycles/h15 cycles/hFor motor use300 cycles/h60 cycles/h––(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.03
1SBC100065S02013/60ABB MOTOR PROTECTION AND CONTROLMain pole utilization characteristics - 3 N.O. non-reversing contactorsContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96HVAC application - UL / CSADefinite purpose heating rating - 3-phaseFull Load Amps (FLA)20 A25 A30 A45 A50 A50 A60 A80 A90 A105 A115 ALocked Rotor Amps (LRA)200-208 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A220-240 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A440-480 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A550-600 V AC 80 A100 A120 A180 A200 A200 A240 A320 A360 A420 A460 ADefinite purpose air conditioning rating - 3-phaseFull Load Amps (FLA)20 A25 A30 A45 A50 A50 A60 A80 A90 A105 A115 ALocked Rotor Amps (LRA)200-208 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A220-240 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A440-480 V AC 120 A150 A180 A270 A300 A300 A360 A480 A540 A630 A690 A550-600 V AC 80 A100 A120 A180 A200 A200 A240 A320 A360 A420 A460 AAC Resistance air heatingFull Load Amps (FLA)600 V AC 20 A25 A30 A45 A50 A50 A65 A80 A90 A105 A115 AElevator control, load switching, 500 000 electrical operating cyclesacc. to CSA B44.1 / ASME 17.5 paragraph 19.2.11-phaseHorse power rating110-120 V AC 1/4 hp 1/3 hp(1)1-1/2 hp 2 hp2 hp3 hp3 hp3 hp5 hp5 hp220-240 V AC 1/2 hp 3/4 hp(1)3 hp3 hp5 hp5 hp7-1/2 hp 10 hp10 hp10 hp3-phaseHorse power rating 200-208 V AC 1 hp2 hp(1)5 hp7-1/2 hp 7-1/2 hp 10 hp10 hp15 hp15 hp15 hp220-240 V AC 1 hp2 hp(1)5 hp7-1/2 hp 10 hp10 hp15 hp20 hp20 hp20 hp440-480 V AC 3 hp5 hp(1)15 hp20 hp20 hp25 hp30 hp40 hp40 hp40 hp550-600 V AC 3 hp5 hp(1)15 hp20 hp20 hp30 hp40 hp40 hp50 hp50 hpElevator control, 500 000 mechanical operating cycles, 5 electrical operating cyclesacc. to CSA B44.1 / ASME 17.5 paragraph 19.2.21-phaseHorse power rating110-120 V AC 3/4 hp 1 hp1-1/2 hp 2 hp2 hp3 hp3 hp3 hp5 hp7-1/2 hp 7-1/2 hp220-240 V AC 1-1/2 hp 2 hp3 hp3 hp5 hp7.5 hp7-1/2 hp 7-1/2 hp 10 hp15 hp20 hp3-phaseHorse power rating 200-208 V AC 2 hp3 hp5 hp7-1/2 hp 10 hp10 hp10 hp15 hp20 hp25 hp30 hp220-240 V AC 2 hp3 hp5 hp7-1/2 hp 10 hp10 hp15 hp20 hp25 hp30 hp30 hp440-480 V AC 5 hp7-1/2 hp 10 hp15 hp20 hp25 hp30 hp40 hp50 hp60 hp60 hp550-600 V AC 7-1/2 hp 10 hp15 hp20 hp25 hp30 hp40 hp50 hp60 hp75 hp75 hpLighting application - UL / CSATungsten lamps1-phase per pole347 V AC 20 A25 A30 A45 A50 A50 A65 A80 A90 A105 A115 A3-phase break all lines600 V AC 20 A25 A30 A45 A50 A50 A65 A80 A90 A105 A115 AElectrical discharge lamps (ballast)1-phase per pole347 V AC 20 A25 A30 A45 A50 A50 A65 A80 A90 A105 A115 A3-phase break all lines600 V AC 20 A25 A30 A45 A50 A50 A65 A80 A90 A105 A115 A(1) 3-pole AF16 cannot be used. Select 4-pole non-reversing contactor AF16..-40-..—AF09 ... AF96 3-pole contactorsTechnical data03
1SBC100069S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/61Main pole utilization characteristics - 3 N.O. non-reversing contactorsContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370HVAC application - UL / CSADefinite purpose heating rating - 3-phaseFull Load Amps (FLA)116 A125 A160 A200 A250 A300 A350 A520 ALocked Rotor Amps (LRA)200-208 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A220-240 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A440-480 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A550-600 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 ADefinite purpose air conditioning rating - 3-phaseFull Load Amps (FLA)116 A125 A160 A200 A250 A300 A350 A520 ALocked Rotor Amps (LRA)200-208 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A220-240 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A440-480 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 A550-600 V AC 800 A875 A1050 A1400 A1500 A2100 A2450 A3120 AAC Resistance air heatingFull Load Amps (FLA)600 V AC 160 A200 A200 A250 A300 A400 A450 A520 AElevator control, load switching, 500 000 electrical operating cyclesacc. to CSA B44.1 / ASME 17.5 paragraph 19.2.13-phaseHorse power rating 200-208 V AC 15 hp15 hp15 hp20 hp30 hp40 hp40 hp50 hp220-240 V AC 20 hp20 hp20 hp25 hp30 hp40 hp50 hp60 hp440-480 V AC 40 hp40 hp40 hp60 hp75 hp100 hp100 hp125 hp550-600 V AC 50 hp50 hp50 hp75 hp100 hp125 hp150 hp150 hpElevator control, 500 000 mechanical operating cycles, 5 electrical operating cyclesacc. to CSA B44.1 / ASME 17.5. paragraph 19.2.23-phaseHorse power rating 200-208 V AC 30 hp40 hp40 hp50 hp60 hp75 hp100 hp125 hp220-240 V AC 40 hp50 hp50 hp60 hp75 hp100 hp125 hp150 hp440-480 V AC 75 hp100 hp100 hp125 hp150 hp200 hp250 hp300 hp550-600 V AC 100 hp125 hp125 hp150 hp200 hp250 hp300 hp350 hpLighting application - UL / CSATungsten lamps1-phase per pole347 V AC – –––––––3-phase break all lines600 V AC – –––––––Electrical discharge lamps (ballast)1-phase per pole347 V AC 160 A200 A200 A250 A300 A400 A450 A520 A3-phase break all lines600 V AC 160 A200 A200 A250 A300 A400 A450 A520 A—AF116 ... AF370 3-pole contactorsTechnical data03
—AF09 ... AF38 3-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38Rated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactorOperationFitted with thermal overload relay-25...+60 °CWithout thermal overload relay-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionA30 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstand5...300 Hzacc. to IEC 60068-2-64 g closed position / 2 g open position(1) Environment B: all AF09...AF38 produced since week 08.2013.AF09...AF38-..-..-12 (48 ...130 V 50 / 60 Hz - DC) compliant to environment A only: for environment B, select AF09...AF38Z-..-..-22.Mounting characteristics and conditions for useContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF09 ... AF38Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally3/62ABB MOTOR PROTECTION AND CONTROL1SBC101427S0201 - Rev. C03
—AF09 ... AF38 3-pole contactorsTechnical dataMagnet system characteristics for AF09 ... AF38 contactors - AC / DC operatedContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38Coil operating limitsacc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max. AC control voltage 50/60 HzRated control circuit voltage Uc24...500 V ACCoil consumptionAverage pull-in value50 VA Average holding value2.2 VA / 2 W DC control voltageRated control circuit voltage Uc20...500 V DCCoil consumptionAverage pull-in value50 W Average holding value2 W PLC-output controlNot suitable for direct control by PLC outputDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity–acc. to SEMI F47-0706Dips withstand–-20 °C ≤ θ ≤ +60 °COperating timeBetween coil energization and:N.O. contact closing40...95 msN.C. contact opening38...90 msBetween coil de-energization and:N.O. contact opening11...95 ms N.C. contact closing13...98 msMagnet system characteristics for AF09Z ... AF38Z 24 DC operated - designed for PLC - coil 30Contactor typesDC operatedAF09ZAF12ZAF16ZAF26ZAF30ZAF38ZCoil operating limitsacc. to IEC 60947-4-1DC supplyAt θ ≤ 60 °C 0.85...1.1 x Uc At θ ≤ 70 °C UcDC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull-in value6 W Average holding value1.7 W PLC-output control≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detectionDrop-out voltage≤ 60 % of Uc min.Operating timeBetween coil energization and:N.O. contact closing27...53 msN.C. contact opening20...35 msBetween coil de-energization and:N.O. contact opening17...29 ms N.C. contact closing22...57 msMagnet system characteristics for AF09Z ... AF38Z for specific applications - coils 20, 21, 22, 23Contactor typesAC / DC operatedAF09ZAF12ZAF16ZAF26ZAF30ZAF38ZCoil operating limitsacc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max. AC control voltageRated control circuit voltage Uc24...250 V ACCoil consumptionAverage pull-in value16 VA Average holding value1.7 VA / 1.5 WDC control voltageRated control circuit voltage Uc12...250 V DCCoil consumptionAverage pull-in value12...16 W Average holding value1.7 WPLC-output control(AF..Z coil 21) ≥ 500 mA 24 V DC for PLCs - not suitable for safety PLCsDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity(AF..Z coil 21, 22, 23) conditions of use on requestacc. to SEMI F47-0706Dips withstand(AF..Z coil 21, 22, 23) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DC-20 °C ≤ θ ≤ +60 °COperating timeBetween coil energization and:N.O. contact closing40...95 msN.C. contact opening38...90 msBetween coil de-energization and:N.O. contact opening11...95 ms N.C. contact closing13...98 ms ABB MOTOR PROTECTION AND CONTROL 3/631SBC100489S0201 - Rev. C03
—AF40 ... AF96 3-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF40AF52AF65AF80AF96Rated insulation voltage Uiacc. to IEC 60947-4-1690 V1000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kV8 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactorOperationFitted with thermal overload relay-40...+70 °CWithout thermal overload relay-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionA25 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstand5...300 Hzacc. to IEC 60068-2-63 g closed position / 3 g open positionMagnet system characteristicsContactor typesAC / DC operatedAF40AF52AF65AF80AF96Coil operating limitsacc. to IEC 60947-4-1AC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.DC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max. AC control voltage 50/60 HzRated control circuit voltage Uc24...500 V ACCoil consumptionAverage pull-in value25 VA 40 VAAverage holding value4 VA / 2 W DC control voltageRated control circuit voltage Uc20...500 V ACCoil consumptionAverage pull-in value25 W 40 WAverage holding value2 W PLC-output control–Drop-out voltage≤ 60 % of Uc min.Voltage sag immunityconditions of use on requestacc. to SEMI F47-0706Dips withstand24 ms average-20 °C ≤ θ ≤ +60 °COperating timeBetween coil energization and:N.O. contact closing42...100 msN.C. contact opening38...95 msBetween coil de-energization and:N.O. contact opening17...100 ms N.C. contact closing19...105 msMounting characteristics and conditionsContactor typesAC / DC operatedAF40AF52AF65AF80AF96Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF40 ... AF96Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mm35 x 15 mmBy screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally3/64ABB MOTOR PROTECTION AND CONTROL1SBC100488S0201 - Rev. C03
1SFC101112C0201 ABB MOTOR PROTECTION AND CONTROL 3/651SFC101112C0201 - Rev. B—AF116 ... AF370 3-pole contactorsTechnical dataMagnet system characteristicsContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370Coil operating limitsAC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxacc. to IEC 60947-4-1DC supplyAt θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc maxRated control circuit voltage Uc24...500 V AC, 20...500 V DCCoil consumptionAC control voltage 50/60 Hz24...60 V ACAverage pull-in value225 VA165 VA475 VAAverage holding value5.5 VA6 VA8.5 VA48...130 V ACAverage pull-in value170 VA175 VA340 VAAverage holding value4 VA4 VA17 VA100...250 V ACAverage pull-in value130 VA220 VA385 VAAverage holding value6 VA7 VA17.5 VA250...500 V ACAverage pull-in value205 VA185 VA420 VAAverage holding value16 VA16 VA21 VADC control voltage20...60 V DCAverage pull-in value210 W205 W400 WAverage holding value2.5 W2.5 W3.5 W48...130 V DCAverage pull-in value130 W130 W360 WAverage holding value2.5 W2.5 W2.5 W100...250 V DCAverage pull-in value135 W190 W410 WAverage holding value3 W2.5 W4.5 W250...500 V DCAverage pull-in value205 W190 W600 WAverage holding value4 W4 W4.7 WDrop-out voltage55 % of Uc minVoltage sag immunity acc. to SEMI F47Conditions of use on requestDips withstand≥ 20 msOperating time Coil supply between A1 - A2Between coil energization and:N.O. contact closing20...55 ms25...60 ms30...60 msBetween coil de-energization and*:N.O. contact opening40..70 ms45...80 ms45...80 ms(*) less than 20ms when using coil code -33 and -34Mounting characteristics and conditions for useContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor AF116 ... AF370Mounting distancesThe contactors can be assembled side by sideFixingOn rail acc. to IEC 60715, EN 60715–By screws4 x M44 x M5General technical dataContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.8 kVElectromagnetic compatibilityAF contactors comply with IEC 60947-1 / EN 60947-1 - Environment AAmbient air temperature close to contactorOperationFitted with thermal overload relay-25 to +55 °CWithout thermal overload relay-40 to +70 °CStorage-40 to +70 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles5 million operating cyclesMaximum switching frequency300 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1No change in contact position, closed or open positionB2AAB1C2C1ABBShock direction1/2 sinusoidal shock for 11 ms1/2 sinusoidal shock for 30 msA20 g20 gB1 15 g closed position / 3 g open position15 g closed position / 3 g open positionB2 15 g closed position / 3 g open position15 g closed position / 3 g open positionC1 20 g20 gC2 20 g20 gVibration withstandacc to IEC 60068-2-60.7 g closed position / 0.7 g open position 13.2...100 Hz03
1SFC101113C0201 - Rev. E3/66ABB MOTOR PROTECTION AND CONTROL—AF400 ... AF750 3-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF400AF460AF580AF750Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.8 kVElectromagnetic compatibilityAF contactors complying with IEC 60947-1 / EN 60947-1 - Environment AAmbient air temperature close to contactorOperationFitted with electronic overload relay-25 to +70 °CWithout electronic overload relay-40 to +70 °CStorage-40 to +70 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles3 millions operating cycles (contacts needs to be replaced every 0,75 millions operating cycles)Max. switching frequency300 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1ABBShock direction1/2 sinusoidal shock for 30 ms: no change in contact position, closed or open positionA5 gB15 gB25 gC15 gC25 gVibration withstandacc to IEC 60068-2-60.7 g closed position / 0.7 g open position 13.2...100 HzMagnet system characteristicsContactor typesAC / DC operatedAF400AF460AF580AF750Coil operating limitsAC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxacc. to IEC 60947-4-1DC supplyAt θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc maxRated control circuit voltage Uc48...500 V AC, 24...500 V DCCoil consumptionAC control voltage 50/60 Hz48...130 V ACAverage pull-in value1215 VA1100 VAAverage holding value12 VA12 VA100...250 V ACAverage pull-in value955 VA880 VAAverage holding value12 VA12 VA250 ... 500 V ACAverage pull-in value950 VA985 VAAverage holding value12 VA12 VADC control voltage24...60 V DCAverage pull-in value900 W785 WAverage holding value5 W5.5 W48...130 V DCAverage pull-in value1150 W1020 WAverage holding value5 W5 W100...250 V DCAverage pull-in value895 W880 WAverage holding value5 W5 W250 ... 500 V DCAverage pull-in value885 W910 WAverage holding value7.5 W7.5 WDrop-out voltage55 % of Uc min.Voltage sag immunity acc. to SEMI F47Conditions of use on requestDips withstand≥ 20 msOperating timeCoil supply between A1 - A2Between coil energization and:Main contact closing50...120 msBetween coil de-energization and:Main contact opening33...70 msControl input for PLC'sBetween coil energization and:Main contact closing40...60 ms40...90 msBetween coil de-energization and:Main contact opening10...30 msMounting characteristics and conditions for useContactor typesAC / DC operatedAF400AF460AF580AF750Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor AF400 ... AF2650Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 60715–By screws4 x M54 x M603
1SFC101113C0201 ABB MOTOR PROTECTION AND CONTROL 3/671SFC101113C0201 - Rev. E—AF1250 ... AF2850 3-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850Rated insulation voltage Uiacc. to IEC 60947-4-1acc. to UL / CSA1000 VRated impulse withstand voltage Uimp.Electromagnetic compatibilityAmbient air temperature close to contactorOperationFitted with electronic overload relay-25 to +70 °CWithout electronic overload relay-40 to +70 °CStorage-40 to +70 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles0.5 million operating cycles0.3 million operating cyclesMax. switching frequency300 cycles/h60 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1ABBShock directionA5 g–B15 g–B25 g–C15 g–C25 g–Vibration withstandacc to IEC 60068-2-60.7 g closed position / 0.7 g open position 13.2...100 HzMagnet system characteristicsContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850Coil operating limitsAC supplyacc. to IEC 60947-4-1DC supplyRated control circuit voltage Uc100...250 V AC or DCCoil consumptionAC control voltage 50/60 Hz48...130 V ACAverage pull-in value1100 VA-Average holding value12 VA-100...250 V ACAverage pull-in value880 VA2450 VAAverage holding value12 VA48 VA250 ... 500 V ACAverage pull-in value985 VA-Average holding value12 VA-DC control voltage24...60 V DCAverage pull-in value785 W-Average holding value5.5 W-48...130 V DCAverage pull-in value1020 W-Average holding value5 W-100...250 V DCAverage pull-in value880 W2290 WAverage holding value5 W20.5 W250 ... 500 V DCAverage pull-in value910 W-Average holding value7.5 W-Drop-out voltage55 % of Uc min.Voltage sag immunityacc. to SEMI F47Conditions of use on requestDips withstand≥ 20 msOperating timeCoil supply between A1 - A2Between coil energization and:Main contact closing50...120 ms50...80 msBetween coil de-energization and:Main contact opening33...70 ms35...55 msControl input for PLC'sBetween coil energization and:Main contact closing40...90 ms40...65 msBetween coil de-energization and:Main contact opening10...30 ms10...30 msMounting characteristics and conditions for useContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor AF400 ... AF2650Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 60715–By screws4 x M64 x M803
—AF09 ... AF38 3-pole contactorsTechnical dataConnecting characteristicsContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38Main terminalsScrew terminals with cable clampConnection capacity (min. ... max.)Main conductors (poles)RigidSolid (≤ 4 mm²)1 x 1...6 mm²2.5...10 mm²Stranded (≥ 6 mm²)2 x 1...6 mm²2.5...10 mm²Flexible with non insulated ferrule1 x 0.75...6 mm²1.5...10 mm²2 x 0.75...6 mm²1.5...10 mm²Flexible with insulated ferrule1 x 0.75...4 mm²1.5...10 mm²2 x 0.75...2.5 mm²1.5...4 mm²L6Bars or lugsL <9.6 mm12.5 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 16...10AWG 14...8Stripping length10 mm14 mmTightening torque1.5 Nm / 13 lb.in2.5 Nm / 22 lb.inAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torqueCoil terminals1.2 Nm / 11 lb.inBuilt-in auxiliary terminals1.2 Nm / 11 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20Coil terminalsIP20Built-in auxiliary terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM3.5M4Screwdriver typeFlat Ø 5.5 / Pozidriv 2Flat Ø 6.5 / Pozidriv 2Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Built-in auxiliary terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 23/68ABB MOTOR PROTECTION AND CONTROL1SBC101428S0201 - Rev. A03
1SBC101746S0201 ABB MOTOR PROTECTION AND CONTROL 3/69Connecting characteristicsContactor typesAC / DC operatedAF40AF52AF65AF80AF96Main terminalsScrew terminals with double connector2 x (9.3 width x 7.9/10.3 depth)Screw terminals with double connector2 x (12.4 width x 9.3/11.1 depth)Connection capacity (min. ... max.)Main conductors (poles)Rigid Stranded (≥ 6 mm²)1 x 6...35 mm²6...70 mm²2 x 6...35 mm²6...50 mm²Flexible with non insulated ferrule1 x 4...35 mm²6...50 mm²2 x 4...35 mm²6...50 mm²Flexible with insulated ferrule1 x 4...35 mm²6...50 mm²2 x 4...35 mm²6...50 mm²L6Bars or lugsL <9.2 mm12.2 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 10...2AWG 6...1Stripping length16 mm17 mmTightening torque4 Nm / 35 lb.in6 Nm / 53 lb.inAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torqueCoil terminals1.2 Nm / 11 lb.inBuilt-in auxiliary terminals1.2 Nm / 11 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP10Coil terminalsIP20Built-in auxiliary terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM6M8Screwdriver typeFlat Ø 6.5 / Pozidriv 2Hexagon socket (s = 4 mm)Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Built-in auxiliary terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2—AF40 ... AF96 3-pole contactorsTechnical data03
1SFC101114C0201 - Rev. A3/70ABB MOTOR PROTECTION AND CONTROLConnecting characteristicsContactor typesAC / DC operatedAF116AF140AF146AF190AF205AF265AF305AF370Main terminalsFlat typeø 6.51373ø 8.517.5105ø 10.519.514.35Connection capacity (min. ... max.)Main conductors (poles) Cu cable - Stranded1 x 10...95 mm²6...150 mm²16...300 mm²Clamp typeLD... included (1)1SDA066917R11SDA055016R1Tightening torque8 Nm14 Nm25 NmCu cable - Stranded 2 x 10...95 mm²50...120 mm²70...185 mm²Clamp typeLD... included (1)1SFN074709R1000, LZ185-2C/1201SCA022194R0890, OZXB4Tightening torque8 Nm16 Nm22 NmAl cable - Stranded1 x–95...185 mm²185...240 mm²Clamp type–1SDA054988R11SDA055020R1Tightening torque–31 Nm43 NmCu cable - Flexible1 x 10...70 mm²6...120 mm²16...240 mm²Clamp typeLD... included (1)1SDA066917R11SDA055016R1Tightening torque8 Nm14 Nm25 Nm Cu cable - Flexible2 x 10...70 mm²50...95 mm²70...185 mm²Clamp typeLD... included (1)1SFN074709R1000, LZ185-2C/1201SCA022194R0890, OZXB4Tightening torque8 Nm16 Nm22 NmLøLugsL ≤ 22 mm (.866 in)24 mm (.945 in)32 mm (1.260 in)Ø > 6 mm (.236 in)8 mm (.315 in)10 mm (.394 in)Socket typeLL... includedLL... includedLL... includedTightening torque9 Nm / 80 lb.in18 Nm / 160 lb.in28 Nm / 248 lb.inConnection capacity acc. to UL / CSA1 x AWG 6...3/06...300 MCM4...400 MCMClamp typeLD... included (1)ATK185 (2)ATK300 (2)Tightening torque8 Nm / 71 lb.in34 Nm / 301 lb.in42 Nm / 372 lb.inConnection capacity acc. to UL / CSA2 x AWG 6...3/0– 4...500 MCMClamp typeLD... included (1)–ATK300/2 (2)Tightening torque8 Nm / 71 lb.in–42 Nm / 372 lb.inAuxiliary conductors(coil terminals)Solid / stranded1 x 1...4 mm²2 x 1...4 mm²Flexible1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL <8 mml > 3.5 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length9 mmTightening torque1.00 Nm / 9 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM6M8M10Screwdriver typeScrews and boltsCoil terminals (delivered in open position)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 2(1) LD... not included for AF116 ... AF146-30-..B. (2) Available in North America only.—AF116 ... AF370 3-pole contactors Technical data03
1SFC101115C0201 - Rev. C ABB MOTOR PROTECTION AND CONTROL 3/71—AF400 ... AF750 3-pole contactorsTechnical dataConnecting characteristicsContactor typesAC / DC operatedAF400AF460AF580AF750Main terminalsFlat typeø 10.525ø 6.522.56ø 12.540ø 6.522.56AF580AF750Connection capacity (min. ... max.)Main conductors (poles)Cu cable - Stranded2 x 240 mm²–Clamp type1SDA013922R1–Tightening torque35 Nm–Cu cable - Stranded3 x–185 mm²Clamp type–1SDA013956R1Tightening torque35 Nm45 NmAl cable - Stranded2 x 240 mm²–Clamp type1SDA013922R1–Tightening torque35 Nm–3 x–185 mm²Clamp type–1SDA013956R1Tightening torque35 Nm45 NmLøLugsL ≤ 47 mm50 mmØ > 10 mm12 mmTightening torque35 Nm / 310 Ib.in45 Nm / 398 lb.inConnection capacity acc. to UL / CSA2 x 250-500 MCM alt. 2/0 AWG-500 MCM–Clamp typeK6TH alt. ATK580–Tightening torque275 Ib.in–Connection capacity acc. to UL / CSA3 x 2/0 AWG-400 MCM2/0 AWG-500 MCMClamp typeK6TJATK750/3Tightening torque275 Ib.in375 Ib.inAuxiliary conductors(coil terminals)Solid / stranded1 x 1...4 mm²2 x 1...4 mm²Flexible1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 8 mml > 3.7 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Tightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM10M12Screws and boltsCoil terminals (delivered in open position)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 203
1SFC101115C0201 - Rev. C3/72ABB MOTOR PROTECTION AND CONTROL—AF1250 ... AF2850 3-pole contactorsTechnical dataConnecting characteristicsContactor typesAC / DC operatedAF1250AF1350AF1650AF2050AF2650AF2850Main terminalsFlat type508ø 13272515.5AF1250AF1350, AF16501710ø 138010274030AF205080104030101317ø 13AF2650, AF28508025404017ø 13Connection capacity (min. ... max.)Main conductors (poles)Cu cable - Stranded2 x–Clamp type–Tightening torque–Cu cable - Stranded3 x–Clamp type–Tightening torque–Al cable - Stranded2 x–Clamp type–Tightening torque–3 x–Clamp type–Tightening torque–LøLugsL ≤ 50 mm100 mmØ > 12 mmTightening torque45 Nm / 398 lb.inConnection capacity acc. to UL / CSA2 x 2// 3 x 0.25 in4/0 AWG - 500 MCM4//4 x 0.25 inClamp typebars, use LW1250K7TK ATK1350/4K7TKbarsTightening torque375 Ib.in–Connection capacity acc. to UL / CSA3 x 2/0 AWG-500 MCM 1/0-750 MCM–Clamp typeATK750/3K8TL, K8TM, ATK1650/4K8TL, K8TM, ATK1650/4, ATK1650/6–Tightening torque375 Ib.in500 Ib.in–Auxiliary conductors(coil terminals)Solid / stranded1 x 1...4 mm²2 x 1...4 mm²Flexible1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 8 mml > 3.7 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Tightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM12Screws and boltsCoil terminals (delivered in open position)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 203
Built-in auxiliary contacts according to IECContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free air thermal current Ith - θ ≤ 40 °C16 A Ie / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 W400 V DC 0.15 A / 60 W500 V DC 0.13 A / 65 W600 V DC 0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Afor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts≥ 2 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4, CAT4 aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Mirror contactsBuilt-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA4, CAL4, CAT4 aux. contact blocks) are mirror contacts.acc. to annex F of IEC 60947-4-1Built-in auxiliary contacts according to UL / CSAContactor typesAC / DC operatedAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Max. operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—AF09 ... AF96 3-pole contactorsTechnical data ABB MOTOR PROTECTION AND CONTROL 3/731SBC101445S0201 - Rev. A03
—3-pole contactorsElectrical durability and utilization categoriesGeneralUtilization categories determine the current making and breaking conditions relating to the characteristics of the loads to be controlled by the contactors. International standard IEC 60947-4-1 and European standard EN 60947-4-1 are the stan-dards to be referred to.If Ic is the current to be broken by the contactor and Ie the rated operational current normally drawn by the load, then:•Categories AC-1 and AC-3: Ic = Ie•Category AC-2: Ic = 2.5 x Ie•Category AC-4: Ic = 6 x IeGenerally speaking Ic = m x Ie where m is a multiple of the load operational current.On next pages, the curves corresponding to categories AC-1, AC-3 and AC-4 represent the electrical durability variation ofstandard contactors in relation to the breaking current Ic.Electrical durability is expressed in millions of operating cycles.Curve utilization modeElectrical durability forecast and contactor selection for categories AC-1, AC-2, AC-3 or AC-4•Note the characteristics of the load to be controlled: - Operational voltage .....................Ue - Current normally drawn ..............Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents"). - Utilization category .....................AC-1, AC-2, AC-3 or AC-4 - Breaking current ...........................Ic = Ie for AC-1 and for AC-3 ; Ic = 2.5 x Ie for AC-2 ; Ic = 6 x Ie for AC-4•Define the number of operating cycles N required.•On the diagram corresponding to the operational category, select the contactor with the curve immediately above the in-tersection point (Ic ; N).Electrical durability forecast and contactor selection for mixed duty motor control: AC-3 (Ic = Ie) type switching off while "motor running" and, occasionally, AC-4 (Ic = 6 x Ie) type switching off while "motor accelerating"•Note the characteristics of the motor to be controlled: - Operational voltage ...........................................................Ue -Current normally drawn while "motor running" ..........Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents") - Breaking current for AC-3 .................................................Ic = Ie -Breaking current for AC-4 while "motor accelerating" Ic = 6 x Ie - Percentage of AC-4 operating cycles ............................K (on the basis of the total number of operating cycles)•Define the total number of operating cycles N required.•Note the smallest contactor rating compatible for AC-3 (Ue / Ie) on Main pole utilization characteristic table (see “Technicaldata”).•For the selected contactor make a note of the following in relation to the voltage using diagram AC-3 in next pages: -The number of operating cycles A for Ic = Ie (AC-3) -The number of operating cycles B for Ic = 6 x Ie (AC-4)•Calculate the estimated number of cycles N’ (N’ is always below A)N'= A 1 + 0.01 K (A/B - 1)•If N' is too low in relation to the target N, calculate the estimated number of cycles for a higher contactor rating.Case of uninterrupted dutyFor uninterrupted duty, some verifications of preventing maintenance are necessary to check the functionality of the con-cerned product (consult us). The combined effect of environmental conditions and the proper temperature of the product may require some disposals. As a matter of fact, for this duty, the use duration prevails over the number of operating cycles.3/ 74ABB MOTOR PROTECTION AND CONTROL1SBC101314S0201 03
—3-pole contactorsElectrical durabilityElectrical durability for AC-1 utilization category - Ue ≤ 690 VSwitching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load.Ambient temperature and maximum electrical switching frequency: see "Technical data".13579135791591357913579135791357913579159135791010.10.20.30.535101001000235203050200300500AF400AF460AF580AF750226.5AF09AF12AF16AF26AF30, AF38AF40AF52AF65AF116AF140AF146AF190AF205AF265AF305AF370AF80, AF96Millions of operatingcyclesBreaking current Ic (A)AF1250, AF1350, AF1650, AF2050:The electrical durability at the rated current is 50000 operating cycles. Note: * For AF580 and AF750 contacts needs to be replaced after 750k operations.Example:Ic / AC-1 = 26.5 A – Electrical durability required = 2 millions operating cycles.Using the AC-1 curves above select the AF26 contactor at intersection "" (26.5 A / 2 millions operating cycles).* * ABB MOTOR PROTECTION AND CONTROL 3/751SBC101940S020103
—3-pole contactorsElectrical durabilityElectrical durability for AC-3 utilization category - Ue ≤ 440 V.Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current).Ambient temperature and maximum electrical switching frequency: see "Technical data".1011010010002352030502003005000.20.30.52351357913579135791357913579135791591591357913579AF400AF460AF580AF7501.855AF09AF12AF16AF26AF40AF52AF65AF116AF190AF205AF305AF370AF265AF30, AF38AF80, AF96AF140, AF146Millions of operatingcyclesBreaking current Ic (A)AF1350, AF1650:The electrical durability at the rated current is 50000 operating cycles. Note: * For AF580 and AF750 contacts needs to be replaced after 750k operations.Example:Motor power 30 kW for AC-3 - Ue = 400 V and Ie = 55 A utilization – Electrical durability required = 1.8 million operating cycles.For AC-3: Ic = Ie. Select the AF65 contactor at intersection "" (55 A / 1.8 million operating cycles) on the curves (AC-3 - Ue ≤ 440 V).* *3/76ABB MOTOR PROTECTION AND CONTROL1SBC101941S020103
—3-pole contactorsElectrical durabilityElectrical durability for AC-3 utilization category - 440 V < Ue ≤ 690 V. Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current).Ambient temperature and maximum electrical switching frequency: see "Technical data".Note: * For AF580 and AF750 contacts needs to be replaced after 750k operations.Example:Motor power 132 kW for AC-3 - Ue = 660 V and Ie = 140 A utilization – Electrical durability required = 1.5 million operating cycles.For AC-3: Ic = Ie. Select the AF265 contactor at intersection "" (140 A / 1.5 million operating cycles) on the curves (AC-3 - 440 V < Ue ≤ 690 V).1357913579159135791357913579135791357913579135791011010010002352030502003005000.20.30.5235AF09AF12AF16AF26AF30AF38AF40AF52AF65AF116AF140AF146AF190AF205AF265AF305AF370AF80AF96AF400AF460AF580AF7501.5140Millions of operating cyclesBreaking current Ic (A)AF1350, AF1650:The electrical durability at the rated current is 50000 operating cycles. * * ABB MOTOR PROTECTION AND CONTROL 3/771SBC101955S020103
—3-pole contactorsElectrical durabilityElectrical durability for AC-2 or AC-4 utilization category - Ue ≤ 440 VAmbient temperature ≤ 60 °C for AF09 ... AF370, ≤ 55 °C for AF400 ... AF1650Switching cage motors: starting, reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keeping in mind that Ie is the motor rated operational current (Ie = motor full-load current).Maximum electrical switching frequency: see "Technical data".3000100010010235203050200300500200050001010.10.0050.010.020.030.050.30.20.52351357913579135791357913579135791357913579AF400AF460AF580AF750AF12AF16AF09AF26AF30, AF38AF40AF80, AF96AF116, AF140,AF146AF205AF265AF190AF65AF52AF305AF370Millions of operatingcyclesBreaking current Ic (A)Note: * For AF580 and AF750 contacts needs to be replaced after 750k operations.* *3/78ABB MOTOR PROTECTION AND CONTROL1SBC101942S0201 - Rev. A03
1SBC101943S0201 ABB MOTOR PROTECTION AND CONTROL 3/79—3-pole contactorsElectrical durabilityElectrical durability for AC-2 or AC-4 utilization category - 440 V < Ue ≤ 690 VAmbient temperature ≤ 60 °C for AF09 ... AF370, ≤ 55 °C for AF400 ... AF750Switching cage motors: starting, reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keaping in mind tha Ie is the motor rated operational current (Ie = motor full load current). Maxi-mum electrical switching frequency: see "Technical data".AF38AF40AF52AF116AF65AF190AF146AF205AF265AF305AF370AF80, AF96AF140 AF30AF26AF16AF12AF0913579135791010.10.0050.010.020.030.050.20.30.523550001000100102352030502003005002000 30001357913579135791357913579AF400AF460AF580AF750Millions of operatingcyclesBreaking current Ic (A)Note: * For AF580 and AF750 contacts needs to be replaced after 750k operations.* * 03
3/80ABB MOTOR PROTECTION AND CONTROL
ABB MOTOR PROTECTION AND CONTROL 3/81— Push-in Spring motor starting solution3/83 Presentation 3/89 OverviewOrdering details 4 to 18.5 kW 3/90 AF09..K ... AF38..K AC / DC operated3/91 AF09Z..K ... AF38Z..K 24 V DC designed for PLC3/92 AF09Z..K ... AF38Z..K AC / DC operated for specific applications3/93 Main accessories3/94 Technical data3/101 Electrical durability 3/404 Voltage code table— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R131003
3/82ABB MOTOR PROTECTION AND CONTROL1SBC100445S0201 03
ABB MOTOR PROTECTION AND CONTROL 3/831SBC100445S0201—Just push itPush-in Spring motor starting solutionWith the new Push-in Spring motor starting solution, one push is all you need for extremely fast wiring. No tool is required, so you can save up to 50% wiring time with Push-in Spring compared to conventional spring solutions. And the connections are just as reliable. So for speed, ease and reliability, just push it.Speed up your projects Faster than ever installationImagine a motor starting solution that’s twice as fast to install. With Push-in Spring, you no longer need to imagine – it’s a reality. Push-in mode allows you to insert both ferruled and rigid cables without the need to use any tools, boosting your productivity like never before.Easy to install Easier than ever wiringPush-in Spring technology opens up new possibilities. With its unmatched ease of use, wiring becomes far more intuitive. This eliminates the need for special training and reduces the chance of wiring error. What possibilities will it open up for you?Continuous operation Reliable as ever connectionsThe speed and ease of Push-in Spring comes with the added reassurance of connections that are as reliable as ever. This gives you complete peace of mind when using the Push-in Spring motor starting solution.03
3/84ABB MOTOR PROTECTION AND CONTROL1SBC100446S0201 —Faster than ever installation2-in-1 connectionFor the very first time, ABB's 2-in-1 connection allows you to use ferruled and rigid cables (Push-in mode) or cables without ferrules (Spring mode) in the same terminal. In Push-in mode, cables can be inserted by just simply pushing them in by hand.Smart accessories100% tool-free connecting kits significantly reduce installation time. Complete solutionHigh connection capacities are optimized for motor starting solutions up to 18.5 kW 400 V AC-3 and 50 A AC-1 (25 hp 480 V and 45 A general use). This includes short-circuit fuseless protection up to 100 kA. Push-in Spring accessories can be mounted on the standard screw range of manual motor starters and contactors.03
ABB MOTOR PROTECTION AND CONTROL 3/851SBC100446S0201Intuitive wiringWith Push-in Spring, all cables and connecting links use the same round shape entry, whilst the square terminals above are clearly marked with screwdriver symbols. The result? Wiring and de-wiring that’s intuitive and easily repeatable without cabling error, with little to no training required.Just one screwdriver requiredFor de-wiring, only one screwdriver size is needed for the entire range. No twisting or turning is required either, so there's less chance of damage to the terminals and to your installation as a whole.Automated wiringThe Push-in Spring motor starting solution features 90° cable insertion for all terminals. Front access to terminals aids smooth, robust insertion of cables and makes automated robot wiring possible. —Easier than ever wiring03
3/86ABB MOTOR PROTECTION AND CONTROL1SBC100446S0201 —Reliable as ever connectionsRobust electrical contactThe special spring design guarantees excellent electrical contact. The design provides strict control of contact strength, independent from operator, giving you complete assurance. Vibration-proofYou can count on Push-in Spring connections, even in harsh environments. Push-in Spring technology has been shock and vibration tested according to IEC 60068-2-27 and IEC 60068-2-6 standards.No need to re-tightenWith self-tightening terminals, there’s no need to re-tighten after transportation or during the life cycle of the product. High connection strength is guaranteed throughout the whole lifetime of the device.03
Spring Mode This mode is used for small cable cross-sections or for cables without ferrules. It is also used for de-wiring the solution. Before inserting the cable, simply push a screwdriver into the clearly marked holes to open the terminal. ABB’s Spring mode is easier to use than conventional spring technology, with less chance of damage to terminals as no twisting or turning is required.Push-in modeConnect rigid cables or ferruled cables simply by pushing them into the cable holes – no need to use any tools. Push-in mode saves up to 50% wiring time compared to conventional spring solutions and makes installation a breeze. Benefit from intuitive wiring, self-tightening terminals and less chance of wiring error.ABB MOTOR PROTECTION AND CONTROL 3/871SBC100446S020103
3/88ABB MOTOR PROTECTION AND CONTROL1SBC100407S0201—Push-in Spring solutionComplete range, complete efficiencyThe Push-in Spring motor starting solution products provide you with a range of benefits.Compatible with screw rangeMount accessories for control circuits on the screw range up to 30 kW AC-3 400 V on manual motor starters and up to 45 kW AC-3 400 V, 130 A AC-1 on contactors.Tool-less connecting links 100% tool-less mounting connecting links.Robust by design Contact robustness by design, independent from operator.Higher connecting capacity The solution ranges up to 18.5 kW 400 V AC-3 and 50 A AC-1 (25 hp 480 V and 45 A 600 V general use).Just one tool for everything You only need a 3 mm screwdriver in Spring mode as well as for de-wiring the complete solution.2-in-1Benefit from both Push-in modeand Spring mode and useferruled cables or cables withoutferrules in the same terminal.03
ABB MOTOR PROTECTION AND CONTROL 3/891SBC100407S0201AC / DC Control supplyTy peAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KIECAC-3Rated operational powerθ ≤ 60 °C, 380 - 400 V kW45.57.5111518.5Rated operational current380 - 400 V A91218263238AC-1Rated operational currentθ ≤ 40 °C, 690 V A252830455050UL/CSA3-phase Motor Rating 440 - 480 V hp57.510152025General Use Rating600 V A252830424545NEMANEMA size000–1––Main accessories for contactorsAuxiliary contact blocksFront mountingCA4-10K (1 N.O.) CA4-01K (1 N.C.)Side mountingCAL4-11KInterlocking unitsMechanicalVM4Mechanical / ElectricalVEM4K*Surge protectionBuilt-in surge protection* For product availability, please consult your ABB local sales organization.—3-pole contactors and motor protection03
3/90ABB MOTOR PROTECTION AND CONTROL1SBC100428S0201—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminals4 to 18.5 kWAC / DC operated AF09-30-10K1SBC101560V0014AF26-30-00K1SBC101562V001445 1.77"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" AF09..K, AF12..K, AF16..K82 3.22"10.5 0.41"45 1.77"80 3.15"86 3.39"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59" AF26..K, AF30..K, AF38..KMain dimensions mm, inchesAF09..K ... AF38..K contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening•built-in surge suppression•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType (1)Order codeWeightPkg(1 pce)Rated operational3-phasemotor ratingGeneral use ratingpowercurrentθ ≤ 40 °C400 V480 V600 V ACAC-3AC-1kWAhpAV 50/60 HzV DCkg4 25 5 25 24 ... 60 20 ... 601 0AF09-30-10K-111SBL137005R11100.2850 1AF09-30-01K-111SBL137005R11010.28548 ... 130 48 ... 1301 0AF09-30-10K-121SBL137005R12100.2850 1AF09-30-01K-121SBL137005R12010.285100 ... 250 100 ... 2501 0AF09-30-10K-131SBL137005R13100.2850 1AF09-30-01K-13 1SBL137005R13010.285250 ... 500 250 ... 5001 0AF09-30-10K-141SBL137005R14100.3250 1AF09-30-01K-141SBL137005R14010.3255.5 28 7.528 24 ... 60 20 ... 601 0AF12-30-10K-111SBL157005R11100.2850 1AF12-30-01K-111SBL157005R11010.28548 ... 130 48 ... 1301 0AF12-30-10K-121SBL157005R12100.2850 1AF12-30-01K-121SBL157005R12010.285100 ... 250 100 ... 2501 0AF12-30-10K-13 1SBL157005R13100.2850 1AF12-30-01K-13 1SBL157005R13010.285250 ... 500 250 ... 5001 0AF12-30-10K-141SBL157005R14100.3250 1AF12-30-01K-141SBL157005R14010.3257.5 30 10 30 24 ... 60 20 ... 601 0AF16-30-10K-111SBL177005R11100.2850 1AF16-30-01K-111SBL177005R11010.28548 ... 130 48 ... 1301 0AF16-30-10K-121SBL177005R12100.2850 1AF16-30-01K-121SBL177005R12010.285100 ... 250 100 ... 2501 0AF16-30-10K-131SBL177005R13100.2850 1AF16-30-01K-13 1SBL177005R13010.285250 ... 500 250 ... 5001 0AF16-30-10K-141SBL177005R14100.3250 1AF16-30-01K-141SBL177005R14010.32511 45 15 42 24 ... 60 20 ... 600 0AF26-30-00K-111SBL237005R11000.32548 ... 130 48 ... 1300 0AF26-30-00K-121SBL237005R12000.325100 ... 250 100 ... 2500 0AF26-30-00K-13 1SBL237005R13000.325250 ... 500 250 ... 5000 0AF26-30-00K-141SBL237005R14000.36515 50 20 45 24 ... 60 20 ... 600 0AF30-30-00K-111SBL277005R11000.33048 ... 130 48 ... 1300 0AF30-30-00K-121SBL277005R12000.330100 ... 250 100 ... 2500 0AF30-30-00K-13 1SBL277005R13000.330250 ... 500 250 ... 5000 0AF30-30-00K-141SBL277005R14000.37018.5 50 25 45 24 ... 60 20 ... 600 0AF38-30-00K-111SBL297005R11000.33048 ... 130 48 ... 1300 0AF38-30-00K-121SBL297005R12000.330100 ... 250 100 ... 2500 0AF38-30-00K-13 1SBL297005R13000.330250 ... 500 250 ... 5000 0AF38-30-00K-141SBL297005R14000.370303
ABB MOTOR PROTECTION AND CONTROL 3/911SBC100498S0201—AF09Z..K ... AF38Z..K 3-pole contactors - with Push-in Spring terminals4 to 18.5 kW24 V DC operated - designed for PLC AF09Z-30-10K AF26Z-30-00K45 1.77"82 3.22"10.5 0.41"91 3.58"97 3.82"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" AF09Z..K, AF12Z..K, AF16Z..K82 3.22"10.5 0.41"45 1.77"100 3.94"106 4.17"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59" AF26Z..K, AF30Z..K, AF38Z..KMain dimensions mm, inchesAF09Z..K ... AF38Z..K contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.• control circuit: DC operated with electronic coil interface allowing low holding consumption up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor ratingGeneral use ratingpowercurrentθ ≤ 40 °C400 V480 V 600 V ACAC-3AC-1kWAhpAV DCkg425525241 0AF09Z-30-10K-301SBL136005R30100.4350 1AF09Z-30-01K-301SBL136005R30010.4355.5287.528241 0AF12Z-30-10K-301SBL156005R30100.4350 1AF12Z-30-01K-301SBL156005R30010.4357.5301030241 0AF16Z-30-10K-301SBL176005R30100.4350 1AF16Z-30-01K-301SBL176005R30010.43511451542240 0AF26Z-30-00K-301SBL236005R30000.44015502045240 0AF30Z-30-00K-301SBL276005R30000.44018.5502545240 0AF38Z-30-00K-301SBL296005R30000.440Note: AF..Z contactors with 24V DC control voltage need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.For product availability, please consult your ABB local sales organization.1SBC101597V00141SBC101599V001403
3/92ABB MOTOR PROTECTION AND CONTROL1SBC100429S0201—AF09Z..K ... AF38Z..K 3-pole contactors - with Push-in Spring terminals4 to 18.5 kWAC / DC operated - for specific applicationsAF09Z-30-10K1SBC101560V0014AF26Z-30-00K1SBC101562V001445 1.77"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" AF09Z..K, AF12Z..K, AF16Z..K82 3.22"10.5 0.41"45 1.77"80 3.15"86 3.39"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59" AF26Z..K, AF30Z..K, AF38Z..KMain dimensions mm, inchesAF09Z..K ... AF38Z..K contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC - can manage large control voltage variations -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request)•built-in surge suppression•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational3-phase motor ratingGeneral use ratingpowercurrentθ ≤ 40 °C400 V480 V600 V ACAC-3AC-1kWAhpAV 50/60 HzV DCkg4 25 5 25 –12 ... 201 0AF09Z-30-10K-201SBL136005R20100.3150 1AF09Z-30-01K-201SBL136005R20010.31524 ... 60 20 ... 601 0AF09Z-30-10K-211SBL136005R21100.3150 1AF09Z-30-01K-211SBL136005R21010.31548 ... 130 48 ... 1301 0AF09Z-30-10K-221SBL136005R22100.3150 1AF09Z-30-01K-221SBL136005R22010.315100 ... 250 100 ... 2501 0AF09Z-30-10K-231SBL136005R23100.3150 1AF09Z-30-01K-231SBL136005R23010.3155.5 28 7.528 –12 ... 201 0AF12Z-30-10K-201SBL156005R20100.3150 1AF12Z-30-01K-201SBL156005R20010.31524 ... 60 20 ... 601 0AF12Z-30-10K-211SBL156005R21100.3150 1AF12Z-30-01K-211SBL156005R21010.31548 ... 130 48 ... 1301 0AF12Z-30-10K-221SBL156005R22100.3150 1AF12Z-30-01K-221SBL156005R22010.315100 ... 250 100 ... 2501 0AF12Z-30-10K-231SBL156005R23100.3150 1AF12Z-30-01K-231SBL156005R23010.3157.5 30 10 30 –12 ... 201 0AF16Z-30-10K-201SBL176005R20100.3150 1AF16Z-30-01K-201SBL176005R20010.31524 ... 60 20 ... 601 0AF16Z-30-10K-211SBL176005R21100.3150 1AF16Z-30-01K-211SBL176005R21010.31548 ... 130 48 ... 1301 0AF16Z-30-10K-221SBL176005R22100.3150 1AF16Z-30-01K-221SBL176005R22010.315100 ... 250 100 ... 2501 0AF16Z-30-10K-231SBL176005R23100.3150 1AF16Z-30-01K-231SBL176005R23010.31511 45 15 42 –12 ... 200 0AF26Z-30-00K-201SBL236005R20000.35524 ... 60 20 ... 600 0AF26Z-30-00K-211SBL236005R21000.35548 ... 130 48 ... 1300 0AF26Z-30-00K-221SBL236005R22000.355100 ... 250 100 ... 2500 0AF26Z-30-00K-231SBL236005R23000.35515 50 20 45 –12 ... 200 0AF30Z-30-00K-201SBL276005R20000.36024 ... 60 20 ... 600 0AF30Z-30-00K-211SBL276005R21000.36048 ... 130 48 ... 1300 0AF30Z-30-00K-221SBL276005R22000.360100 ... 250 100 ... 2500 0AF30Z-30-00K-231SBL276005R23000.36018.5 50 25 45 –12 ... 200 0AF38Z-30-00K-201SBL296005R20000.36024 ... 60 20 ... 600 0AF38Z-30-00K-21 1SBL296005R21000.36048 ... 130 48 ... 1300 0AF38Z-30-00K-22 1SBL296005R22000.360100 ... 250 100 ... 2500 0AF38Z-30-00K-23 1SBL296005R23000.360Note: Only AF..Z contactors with 12...20 V DC control voltage need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.03
—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsMain accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMain polesBuilt-in auxiliary contactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerMechanical interlock unitAuxiliary contact blocks4-pole CA4..K(between 2 contactors)Left sideRight side1-pole CA4..KTEF4SVM42-pole CAL4-11KAF09(Z)..K ... AF38(Z)..K (1)AF09..K ... AF16..K3 00 14 max.or 1or 1–+1–AF09..K ... AF16..K3 01 02 max.–or 1–+1+ 1AF26..K ... AF38..K 3 00 04 max.or 1or 1+ 1+1or 1AF09Z..K ... AF38Z..K 24 V DC designed for PLC - coil 30 (1)AF09Z..K ... AF16Z..K 3 00 14 max.or 1or 1+ 1or1+ 1AF09Z..K ... AF16Z..K 3 01 02 max.–or 1+ 1+1or 1AF26Z..K ... AF38Z..K 3 00 01–+1+ 1(1) Including add-on and built-in contacts: 4 N.C. auxiliary contacts max. on positions 1, 2, 3, 4 and 3 N.C. auxiliary contacts max. on positions 1 ±30°, 5Contactor and main accessories (other accessories available)AF09..K ... AF38..KVM4 Mechanical interlock unitFixing clipsCAL4-11K2-pole auxiliary contact blockCA4..K4-pole auxiliary contact blockTEF4SElectronic timerCA4..K1-pole auxiliary contact blockBX4-CAprotective coverBX4protective coverAF.. K contactorAF.. K contactor1SBC100449S0201 - Rav. AABB MOTOR PROTECTION AND CONTROL 3/9303
3/94ABB MOTOR PROTECTION AND CONTROL1SBC100430S0201—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KStandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C35 A35 A35 A50 A50 A50 AWith conductor cross-sectional area6 mm²6 mm²6 mm²10 mm²10 mm²10 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 25 A28 A30 A45 A50 A50 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 25 A28 A30 A40 A42 A42 Aθ ≤ 70 °C 22 A24 A26 A32 A37 A37 AWith conductor cross-sectional area4 mm²6 mm²6 mm²10 mm²10 mm²10 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 9 A12 A18 A26 A33 A40 A380-400 V 9 A12 A18 A26 A32 A38 A415 V 9 A12 A18 A26 A32 A38 A440 V 9 A12 A18 A26 A32 A38 A500 V 9.5 A12.5 A15 A23 A28 A33 A690 V 7 A9 A10.5 A17 A21 A24 A1000 V–Rated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 2.2 kW3 kW4 kW6.5 kW9 kW11 kW380-400 V 4 kW5.5 kW7.5 kW11 kW15 kW18.5 kW415 V 4 kW5.5 kW9 kW11 kW15 kW18.5 kW440 V 4 kW5.5 kW9 kW15 kW18.5 kW22 kW500 V 5.5 kW7.5 kW9 kW15 kW18.5 kW22 kW690 V 5.5 kW7.5 kW9 kW15 kW18.5 kW22 kW1000 V–Rated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category (without thermal overload relay Ue 400 V 50/60 Hz θ ≤ 40 °C)Ie / Rated operational current AC-8a12 A16 A22 A30 A40 A50 ARated operational power AC-8a5.5 kW7.5 kW11 kW15 kW20 kW25 kWShort-circuit protection device for contactorswithout thermal overload relay in free airMotor protection excluded (2)Ue ≤ 500 V AC - gG type fuse25 A32 A32 A50 A63 A63 ARated short-time withstand current Icw1 s 300 A300 A300 A700 A700 A700 Aat 40 °C ambient temperature,in free air from a cold state10 s 150 A150 A150 A350 A350 A350 A30 s 80 A80 A80 A225 A225 A225 A1 min 60 A60 A60 A150 A150 A150 A15 min 35 A35 A35 A50 A50 A50 AMaximum breaking capacitycos φ = 0.45at 440 V 250 A250 A250 A500 A500 A500 Aat 690 V 106 A106 A106 A200 A200 A200 APower dissipation per poleIe / AC-1 1.14 W1.43 W1.64 W2 W2.44 W2.44 WIe / AC-3 0.15 W0.26 W0.6 W0.66 W1 W1.41 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-2, AC-4300 cycles/h150 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".03
1SBC100434S0201 ABB MOTOR PROTECTION AND CONTROL 3/95—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KStandardsUL 60947-4-1, CSA-C22.2 No. 60947-4-1Maximum operational voltage600 VNEMA size000-1--NEMA continuous amp ratingThermal current9 A18 A27 ANEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 1/3 hp1 hp2 hp230 V AC 1 hp2 hp3 hpNEMA maximum horse power ratings 3-phase, 60 Hz200 V AC 1-1/2 hp3 hp7-1/2 hp230 V AC 1-1/2 hp3 hp7-1/2 hp460 V AC 2 hp5 hp10 hp575 V AC 2 hp5 hp10 hpUL / CSA general use rating600 V AC25 A28 A30 A42 A45 A45 AWith conductor cross-sectional areaAWG 10AWG 10AWG 10AWG 8AWG 8AWG 81 pole80 V DC 25 A28 A30 A42 A45 A45 A2 poles in serie160 V DC 25 A28 A30 A42 A45 A45 A3 poles in serie240 V DC 25 A28 A30 A42 A45 A45 AWith conductor cross-sectional areaAWG 10AWG 10AWG 10AWG 8AWG 8AWG 8UL / CSA maximum 1-phase motor ratingFull load current120 V AC 13.8 A16 A20 A24 A24 A24 A240 V AC 10 A12 A17 A17 A28 A28 AHorse power rating120 V AC 3/4 hp1 hp1-1/2 hp2 hp2 hp2 hp240 V AC 1-1/2 hp2 hp3 hp3 hp5 hp5 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 7.8 A11 A17.5 A25.3 A32.2 A32.2 A220-240 V AC 6.8 A9.6 A15.2 A22 A28 A28 A440-480 V AC 7.6 A11 A14 A21 A27 A34 A550-600 V AC 9 A11 A17 A22 A27 A32 AHorse power rating (1)200-208 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp220-240 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp440-480 V AC 5 hp7-1/2 hp10 hp15 hp20 hp25 hp550-600 V AC 7-1/2 hp10 hp15 hp20 hp25 hp30 hpUL / CSA - DC motor starting - 3 poles in seriesFull Load Amps (FLA)125 V DC 9.5 A13.2 A17 A25 A25 A25 A250 V DC 8.5 A12.2 A12.2 A20 A29 A29 AHorse power rating125 V DC 1 hp1-1/2 hp2 hp3 hp3 hp3 hp250 V DC 2 hp3 hp3 hp5 hp7-1/2 hp7-1/2 hpShort-circuit protection device for contactors without thermal overload relayMotor protection excludedFuse rating30 A60 A100 AFuse type, 600 VRK5Maximum electrical switching frequencyFor general use 600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".03
1SBC100435S02013/96ABB MOTOR PROTECTION AND CONTROL—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical dataMain pole - Utilization characteristics - 3 N.O. non reversing contactorsContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KAC Resistance air heatingFull Load Amps (FLA)600 V AC 20 A25 A30 A42 A45 A45 AElevator control, load switching, 500,000 electrical operating cycles acc. to CSA B44.1 / ASME 17.5 paragraph 19.2.11-phaseHorse power rating110-120 V AC 1/4 hp1/3 hp–1-1/2 hp2 hp2 hp220-240 V AC 1/2 hp3/4 hp–3 hp3 hp5 hp3-phaseHorse power rating 200-208 V AC 1 hp2 hp–5 hp7-1/2 hp7-1/2 hp220-240 V AC 1 hp2 hp–5 hp7-1/2 hp10 hp440-480 V AC 3 hp5 hp–15 hp20 hp20 hp550-600 V AC 3 hp5 hp–15 hp20 hp20 hpElevator control, 500,000 mechanical operating cycles, 5 electrical operating cycles acc. to CSA B44.1 / ASME 17.5 paragraph 19.2.21-phaseHorse power rating110-120 V AC 3/4 hp1 hp1-1/2 hp2 hp2 hp3 hp220-240 V AC 1-1/2 hp2 hp3 hp3 hp5 hp7-1/2 hp3-phaseHorse power rating 200-208 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp220-240 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp440-480 V AC 5 hp7-1/2 hp10 hp15 hp20 hp25 hp550-600 V AC 7-1/2 hp10 hp15 hp20 hp25 hp30 hpLighting application - UL/CSATungsten lamps1-phase per pole347 V AC 20 A25 A30 A42 A45 A45 A3-phase break all lines600 V AC 20 A25 A30 A42 A45 A45 AElectrical discharge lamps (ballast)1-phase per pole347 V AC 20 A25 A30 A42 A45 A45 A3-phase break all lines600 V AC 20 A25 A30 A42 A45 A45 A03
ABB MOTOR PROTECTION AND CONTROL 3/971SBC100436S0201 - Rev. A—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactorOperationWithout thermal overload relay-40 ... +70 °CStorage-60 ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 million operating cyclesMaximum switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionB2AAB1C2C1A30 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstand5 ... 300 Hzacc. to IEC 60068-2-64 g Closed position / 2 g Open position(1) AF09 ... AF38-..-..-12 (48...130 V 50/60 Hz-DC) compliant to environment A only. For environment B: select AF09 ... AF38Z-..-..-22.Mounting characteristics and conditions for useContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KMounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4 Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF09 ... AF38Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally03
3/98ABB MOTOR PROTECTION AND CONTROL1SBC100499S0201—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical dataMagnet System Characteristics for AF09..K ... AF38..K contactors - AC / DC operatedContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KCoil operating limits acc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.At θ ≤ 70 °C 0.85 x Uc min...Uc max. AC control voltage 50/60 HzRated control circuit voltage Uc24 ... 500 V ACCoil consumptionAverage pull-in value 50 VAAverage holding value2.2 VA / 2 W DC control voltageRated control circuit voltage Uc20 ... 500 V DCCoil consumptionAverage pull-in value 50 W Average holding value2 WPLC-output controlNot suitable for direct control by PLC-outputDrop-out voltage≤ 60 % Uc min.Operating timeBetween coil energization and:N.O. contact closing40 ... 95 msN.C. contact opening38 ... 90 msBetween coil de-energization and:N.O. contact opening11 ... 95 msN.C. contact closing13 ... 98 msMagnet System Characteristics for AF09Z..K ... AF38Z..K contactors 24V DC operated - designed for PLC - coil 30Contactor typesAC / DC operatedAF09Z..KAF12Z..KAF16Z..KAF26Z..KAF30Z..KAF38Z..KCoil operating limits acc. to IEC 60947-4-1DC supplyAt θ ≤ 60 °C 0.85 ... 1.1 x UcAt θ ≤ 70 °C UcDC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull-in value 6 WAverage holding value1.7 WPLC-output control≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detectionDrop-out voltage≤ 60 % of Uc min.Operating timeBetween coil energization and:N.O. contact closing27 ... 53 msN.C. contact opening20 ... 35 msBetween coil de-energization and:N.O. contact opening17 ... 29 msN.C. contact closing22 ... 57 msMagnet System Characteristics for AF09Z..K ... AF38Z..K contactors - for specific applications - coils 20, 21, 22, 23Contactor typesAC / DC operatedAF09Z..KAF12Z..KAF16Z..KAF26Z..KAF30Z..KAF38Z..KCoil operating limits acc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc maxAt θ ≤ 70 °C 0.85 x Uc min ... Uc maxDC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 250 V ACCoil consumptionAverage pull-in value 16 VAAverage holding value1.7 VA / 1.5 WDC control voltageRated control circuit voltage Uc12 ... 250 V DCCoil consumptionAverage pull-in value 12 ... 16 WAverage holding value1.7 WPLC-output control(AF..Z coil 21) ≥ 500 mA 24 V DC for PLCsDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706(AF..Z coil 21, 22, 23) conditions of use on requestDips withstand -20 °C ≤ θ ≤ +60°C(AF..Z coil 21, 22, 23) 20 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DCOperating timeBetween coil energization and:N.O. contact closing40 ... 95 msN.C. contact opening38 ... 90 msBetween coil de-energization and:N.O. contact opening11 ... 95 msN.C. contact closing13 ... 98 ms03
ABB MOTOR PROTECTION AND CONTROL 3/991SBC100437S0201Connecting characteristicsContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KMain terminals Push-in Spring terminalsConnection capacity (min. ... max.)Main conductors (poles)Rigid Solid (≤ 2.5 mm²)Stranded (≥ 4 mm²)1 x 1 ... 6 mm²1 ... 10 mm²2 x 1 ... 6 mm²1 ... 10 mm²Flexible with non insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 4 mm²1 ... 6 mm²2 x 1 (push-in) / 0.5 (spring) ... 4 mm²1 ... 6 mm²Flexible with insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 4 mm²1 ... 6 mm²2 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²1 ... 6 mm²Flexible without ferrule1 x (spring) 0.5 ... 4 mm²(spring) 1 ... 6 mm²2 x (spring) 0.5 ... 4 mm²(spring) 1 ... 6 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 18 ... 10AWG 18 ... 8(Solid ≤ AWG 14)Stripping length12 mm14 mmAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 1 ... 2.5 mm²2 x 1 ... 2.5 mm²Flexible with non insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²Flexible with insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²Flexible without ferrule1 x (spring) 0.5 ... 2.5 mm²2 x (spring) 0.5 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 18 ... 14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1and IEC 60529 / EN 60529Main terminalsIP20Coil terminalsIP20Built-in auxiliary terminalsIP20Screwdriver typeAll terminalsFlat Ø 3 mm x 0.5 mm—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical data03
1SBC100438S02013/100ABB MOTOR PROTECTION AND CONTROLBuilt-in auxiliary contacts according to IECContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KRated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free air thermal current Ith - θ ≤ 40 °C16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 W400 V DC 0.15 A / 60 W500 V DC 0.13 A / 65 W600 V DC 0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s100 Afor 0.1 s140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts≥ 2 msPower dissipation per pole at 6 A0.1 WMaximum electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsacc. to annex L of IEC 60947-5-1Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4 aux. contact blocks) are mechanically linked contacts.Mirror contactsacc. to annex F of IEC 60947-4-1Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA4, CAL4 aux. contact blocks) are mirror contacts.Built-in auxiliary contacts according to UL / CSAContactor typesAC / DC operatedAF09..KAF12..KAF16..KAF26..KAF30..KAF38..KMaximum operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsTechnical data03
ABB MOTOR PROTECTION AND CONTROL 3/1011SBC100410S0201—AF09..K ... AF38..K 3-pole contactors with Push-in Spring terminalsElectrical durability and utilization categoriesGeneralUtilization categories determine the current making and breaking conditions relating to the characteristics of the loads to be controlled by the contactors. International standard IEC 60947-4-1 and European standard EN 60947-4-1 are the standards to be referred to.If Ic is the current to be broken by the contactor and Ie the rated operational current normally drawn by the load, then:• Categories AC-1 and AC-3 Ic = Ie• Category AC-2 Ic = 2.5 x Ie• Category AC-4 Ic = 6 x IeGenerally speaking Ic = m x Ie where m is a multiple of the load operational current.On next pages, the curves corresponding to categories AC-1, AC-3 and AC-4 represent the electrical durability variation of standard contactors in relation to the breaking current Ic. Electrical durability is expressed in millions of operating cycles.Curve utilization modeElectrical durability forecast and contactor selection for categories AC-1, AC-2, AC-3 or AC-4CharacteristicsLoad to be controlledOperational voltageUeCurrent normally drawnIe (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents")Utilization categoryAC-1, AC-2, AC-3 or AC-4Breaking currentIc = Ie for AC-1 and for AC-3 ; Ic = 2.5 x Ie for AC-2 ; Ic = 6 x Ie for AC-4• Define the number of operating cycles N required.• On the diagram corresponding to the operational category, select the contactor with the curve immediately above the intersection point (Ic ; N).Electrical durability forecast and contactor selection for mixed duty motor control: AC-3 (Ic = Ie) type switching off while "motor running" and, occasionally, AC-4 (Ic = 6 x Ie) type switching off while "motor accelerating"CharacteristicsLoad to be controlledOperational voltageUeCurrent normally drawn while "motor running" Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents")Utilization categoryAC-1, AC-2, AC-3 or AC-4Breaking current for AC-3 Ic = IeBreaking current for AC-4 while "motor accelerating"Ic = 6 x IePercentage of AC-4 operating cycles K (on the basis of the total number of operating cycles)• Define the total number of operating cycles N required.• Note the smallest contactor rating compatible for AC-3 (Ue / Ie) on Main pole utilization characteristic table (see “Technical data”).• For the selected contactor make a note of the following in relation to the voltage using diagram AC-3 in next pages: -The number of operating cycles A for Ic = Ie (AC-3) -The number of operating cycles B for Ic = 6 x Ie (AC-4)• Calculate the estimated number of cycles N’ (N’ is always below A)N'= A 1 + 0.01 K (A/B - 1)• If N' is too low in relation to the target N, calculate the estimated number of cycles for a higher contactor rating.Case of uninterrupted dutyFor uninterrupted duty, some verifications of preventing maintenance are necessary to check the functionality of the concerned product (consult us). The combinated effect of environmental conditions and the proper temperature of the product may require some disposals. As a matter of fact, for this duty, the use duration prevails over the number of operating cycles.03
—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsElectrical durabilityElectrical Durability for AC-1 Utilization Category - Ue ≤ 690 V. Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load.Ambient temperature and maximum electrical switching frequency: see "Technical Data".13579135791591357913579135791357913579159135791010.10.20.30.535101001000235203050200300500226.5AF09AF12AF16AF26AF30, AF38Millions of operat-ing cyclesBreaking current Ic (A)1SBC100424S02013/102ABB MOTOR PROTECTION AND CONTROL03Example:Ic / AC-1 = 26.5 A – Electrical durability required = 2 millions operating cycles.Using the AC-1 curves above select the AF26 contactor at intersection "" (26.5 A / 2 millions operating cycles).
—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsElectrical durabilityElectrical Durability for AC-3 Utilization Category Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). Ambient temperature and maximum electrical switching frequency: see "Technical Data".1011010010002352030502003005000.20.30.52351357913579135791357913579135791591591357913579AF09AF12AF16AF26AF30, AF381357913579159135791357913579135791357913579135791011010010002352030502003005000.20.30.5235AF09AF12AF16AF26AF30, AF38Millions of operating cyclesMillions of operating cyclesBreaking current Ic (A)Breaking current Ic (A)AC-3 - Ue ≤ 440 V AC-3 - 440 V < Ue ≤ 690 V ABB MOTOR PROTECTION AND CONTROL 3/1031SBC100425S020103
—AF09..K ... AF38..K 3-pole contactors - with Push-in Spring terminalsElectrical durabilityElectrical Durability for AC-2 or AC-4 Utilization Category Switching cage motors: starting reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keeping in mind that Ie is the motor rated operational current Ie (Ie = motor full load current). Ambient temperature ≤ 60 °C. Maximum electrical switching frequency: see "Technical Data".3000100010010235203050200300500200050001010.10.0050.010.020.030.050.30.20.52351357913579135791357913579135791357913579AF12AF16AF09AF26AF30, AF38AF38AF30AF26AF16AF12AF0913579135791010.10.0050.010.020.030.050.20.30.523550001000100102352030502003005002000 30001357913579135791357913579Millions of operating cyclesMillions of operating cyclesBreaking current Ic (A)Breaking current Ic (A)AC-2 or AC-4 - Ue ≤ 440 V AC-2 or AC-4 - 440 V < Ue ≤ 690 V 3/104ABB MOTOR PROTECTION AND CONTROL1SBC100426S020103
ABB MOTOR PROTECTION AND CONTROL 3/105—Notes03
03
—AFS contactors for safety applications3/109 Overview Ordering details 4 to 18.5 kW3/114 AFS09 ... AFS38 AC / DC operated with 2 N.O. + 2 N.C. 18.5 to 45 kW3/115 AFS40 ... AFS96 AC / DC operated with 2 N.O. + 2 N.C. 3/116 AFS09 ... AFS96 Contactors and main accessories3/117 Technical data3/124 Electrical durability3/404 Voltage code table— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R1310 ABB MOTOR PROTECTION AND CONTROL 3/10703
1SBC100321S0201 3/108ABB MOTOR PROTECTION AND CONTROL03
1SBC100321S0201 ABB MOTOR PROTECTION AND CONTROL 3/109—AFS 3-pole contactors with front-mounted auxiliary contactsDedicated for safety applicationsABB’s complete range of safety components make protection systems easier to build. Designed for machine safety applications, AFS contactors come with fixed front or side mounted auxiliary contact blocks, making them ideal for monitoring and controlling circuits. Mechanically linked and mirror contacts help make your system safer.Safety and protectionSafety in all thingsABB’s AFS contactors can be easily integrated in ma‑chine manufacturer’s systems complying with main standards EN ISO 13849 and EN 62061 ‑ guaranteeing the safe use of your machinery and equipment.The AFS contactor range is an integral part of ABB’s comprehensive range of safety products. Continuous operationSecure uptimeThe AFS contactor secures system uptime. It allows direct control by safety PLCs or safety relays to ensure the safety performance customers require, for contactors up to 38 A. A low energy auxiliary contact guarantees PLC feedback.Speed up your projectsSimplify designPerfect design makes integration easier. ABB’s distinctive yellow auxiliary contact block makes identifying the right product quicker. By reducing the contactor coil’s power consumption, panels can also be made smaller and transformers more compact. In addition, all the safety data for the contactors are readily available using safety design tools.03
3/110ABB MOTOR PROTECTION AND CONTROL—AFS contactors with front-mounted auxiliary contact blocksDedicated for safety applicationsSimplify calculation of your installation safety levelAll safety values are available in safety design tool such as Sistema and FSDT, dedicated software for determining the Performance Level (PL) and Safety Integrity Level (SIL) of safety functions and generating technical documentations.Prevent unexpected operationsFront‑mounted contact blocks are permanently fixed to protect devices against accidental misuse and operation. A factory‑fitted transparent cover shields the contactor status indicator, providing additional protection.Contactors status guaranteedABB’s permanently fixed front‑mounted auxiliary contact blocks guarantee the correct contactor status at all times. Mechanically linked and mirror contacts get clearly marked symbols on the front and provide the performance required in feedback circuits. This prevents any unexpected state changes of auxiliary contact if main contacts become welded or stuck and ensures an accurate depiction of the safety system status displayed at all times.Easy safety chain identificationThe yellow housing of ABB’s AFS contactors makes identify‑ing the safety product in your panel quicker. During routine maintenance work, ABB’s intuitive design saves valuable time.03
1SBC100278S0201 ABB MOTOR PROTECTION AND CONTROL 3/111Control by safety PLCs or safety relaysABB’s AFS contactors can be controlled directly by safety PLCs or safety relays. The low energy auxiliary contacts feature a minimum switching capacity 12 V / 3 mA. They guarantee system status feedback, making the system safe and reliable.Fast response for increased safetyWith fast opening times less than 30 ms for selected variants, AFS09 ... AFS38 respond quickly when a dangerous failure is detected. Safety is enhanced and the safety distances of in‑stallations can be significantly shorter.Panel size reductionBy reducing coil energy consumption by up to 60%, panels can be built smaller and transformers can be downsized. With reduced power dissipation in the cabinet, installations also need fewer fans. Using AFS contactors saves money and precious space.Built-in surge suppressionUnlike conventional contactors, ABB's AFS contactors have built‑in surge suppression, preventing surges from ever reaching the control circuit. With no need for the usual ex‑ternal surge suppressor add‑ons, ABB’s solution means one less device to install and one less complication to manage. Sentry safety relayPluto safety PLC03
3/112ABB MOTOR PROTECTION AND CONTROL—AFS contactors for safety applicationsA part of ABB's complete safety solutions03
ABB MOTOR PROTECTION AND CONTROL 3/1131SBC100278S020103
3/114ABB MOTOR PROTECTION AND CONTROL1SBC100306S0201 —AFS09 ... AFS38 3-pole contactors for safety applications4 to 18.5 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAFS16‑30‑221SBC101536V0014AFS38‑30‑221SBC101539V0014AFS09 ... AFS38 contactors are designed for machine safety applications. They are delivered with fixed front‑mounted auxiliary contact blocks making them ideal for monitoring and controlling circuits.Mechanically linked and mirror contacts make your system safer.•control circuit with electronic coil interface: ‑dedicated 24 V DC for direct control by PLC-output ≥ 250 mA, low holding consumption up to 1.7 W ‑24...60 V AC, 20...60 V DC and 100...250 V AC / DC operated accepting a wide control voltage range ‑reduced panel energy consumption•mirror and mechanically linked contacts, with front marked symbol acc. to IEC60947‑5‑1, always guaranteeing the right contactor status•front‑mounted auxiliary contact block: ‑permanently fixed ‑protective cover to prevent manual operation ‑yellow housing for easy identification ‑minimum switching capacity 12 V / 3 mA, with a failure rate 10-7 acc. to IEC 60947‑5‑4•built‑in surge suppressionIECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType (1)Order code WeightPkg(1 pce)Rated operational3-phase motor ratingGeneral use ratingpowercurrentθ ≤ 40 °C400 V480 V 600 V ACAC-3AC-1kWAhpAV 50/60 HzV DCkg425525‑242 2AFS09Z-30-22-301SBL136082R30220.49024 ... 60 20 ... 60(1)2 2AFS09-30-22-11 1SBL137082R11220.320100 ... 250 100 ... 2502 2AFS09-30-22-13 1SBL137082R13220.3205.5287-1/228‑242 2AFS12Z-30-22-301SBL156082R30220.49024 ... 60 20 ... 60(1)2 2AFS12-30-22-111SBL157082R11220.320100 ... 250 100 ... 2502 2AFS12-30-22-13 1SBL157082R13220.3207.5301030‑242 2AFS16Z-30-22-301SBL176082R30220.49024 ... 60 20 ... 60(1)2 2AFS16-30-22-111SBL177082R11220.320100 ... 250 100 ... 2502 2AFS16-30-22-13 1SBL177082R13220.32011451545‑242 2AFS26Z-30-22-301SBL236082R30220.54024 ... 60 20 ... 60(1)2 2AFS26-30-22-111SBL237082R11220.360100 ... 250 100 ... 2502 2AFS26-30-22-13 1SBL237082R13220.36015502050‑242 2AFS30Z-30-22-301SBL276082R30220.54024 ... 60 20 ... 602 2AFS30-30-22-111SBL277082R11220.360100 ... 250 100 ... 250(1)2 2AFS30-30-22-13 1SBL277082R13220.36018.5502550‑242 2AFS38Z-30-22-301SBL296082R30220.54024 ... 60 20 ... 60(1)2 2AFS38-30-22-11 1SBL297082R11220.360100 ... 250 100 ... 2502 2AFS38-30-22-13 1SBL297082R13220.360(1) AFS..-30-..-11 for control by transistor outputs of safety PLCs and safety relays use interface relay RA4 1SBN060100R1000.* For AFS09Z, AFS12Z, AFS16Z-30-22-30: depth + 20 mm (+ 0.79")* For AFS26Z, AFS30Z, AFS38Z-30-22-30: depth + 20 mm (+ 0.79")35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69" AFS09, AFS12, AFS16Main dimensions mm, inches**45 1.77"80 3.15"6 0.24"119.5 4.70"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AFS26, AFS30, AFS38**03
ABB MOTOR PROTECTION AND CONTROL 3/1151SBC100308S0201 —AFS40 ... AFS96 3-pole contactors for safety applications18.5 to 45 kWAC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts AFS65‑30‑221SBC101542V0014 AFS96‑30‑221SBC101544V0014111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69" AFS40, AFS52, AFS6543 1.69"6 0.24"119.5 4.70"70 2.76"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607155.5 0.22" AFS80, AFS96AFS40 ... AFS96 contactors are designed for machine safety applications. They are delivered with fixed front‑mounted auxiliary contact blocks making them ideal for monitoring and controlling circuits. Mechanically linked and mirror contacts make your system safer.• control circuit with electronic coil interface: ‑ 24...60 V AC, 20...60 V DC and 100...250 V AC / DC operated accepting a wide control voltage range ‑ reduced panel energy consumption • mirror and mechanically linked contacts, with front marked symbol acc. to IEC60947‑5‑1, always guaranteeing the right contactor status • front‑mounted auxiliary contact block: ‑ permanently fixed ‑ protective cover to prevent manual operation ‑ yellow housing for easy identification ‑ minimum switching capacity 12 V / 3 mA, with a failure rate 10-7 acc. to IEC 60947‑5‑4 • built‑in surge suppressionIECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe (1)Order codeWeightPkg(1 pce)Rated operational3-phase motor ratingGeneral use ratingpowercurrentθ ≤ 40 °C400 V480 V600 V ACAC-3AC-1kWAhpAV 50/60 HzV DCkg18.5 70 3060 24 ... 6020 ... 60(1)2 2AFS40-30-22-111SBL347082R11221.020100 ... 250100 ... 2502 2AFS40-30-22-131SBL347082R13221.00022 100 4080 24 ... 6020 ... 60(1)2 2AFS52-30-22-111SBL367082R11221.020100 ... 250100 ... 2502 2AFS52-30-22-131SBL367082R13221.00030 105 5090 24 ... 6020 ... 60(1)2 2AFS65-30-22-111SBL387082R11221.020100 ... 250100 ... 2502 2AFS65-30-22-131SBL387082R13221.00037 12560105 24 ... 6020 ... 60(1)2 2AFS80-30-22-111SBL397082R11221.270100 ... 250100 ... 2502 2AFS80-30-22-131SBL397082R13221.22045 13060115 24 ... 6020 ... 60(1)2 2AFS96-30-22-111SBL407082R11221.270100 ... 250100 ... 2502 2AFS96-30-22-131SBL407082R13221.220(1) AFS..-30-..-11 for control by transistor outputs of safety PLCs and safety relays use interface relay R A4 1SBN060100R1000.Main dimensions mm, inches03
3/116ABB MOTOR PROTECTION AND CONTROL1SBC100313S0201 —AFS09 ... AFS96 3-pole contactors for safety applicationsContactors and main accessoriesMain accessory fitting details ‑ for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front‑mounted or side‑mounted.ContactortypesMain polesBuilt-in auxiliary contactsFront-mounted accessoriesMechanical interlock unit(between 2 contactors)VM..Side-mounted accessoriesAuxiliary contact blocksAuxiliary contact blocksElectronic timer2-pole CAL4-11Left sideRight side1-pole CA4 2-pole CAT4-11 4-pole CA4TEF4AFS09 ... AFS383 02 2––––1+1–AFS09Z ... AFS38Z3 02 2––––1––AFS40 ... AFS963 02 2–––––+1+ 1–––––+1or 1Overload relays fitting details (1)Contactor typesThermal overload relaysElectronic overload relays AFS09 ... AFS38TF42 (0.10...38 A)EF19 (0.10...19 A)AFS26 ... AFS38TF42 (0.10...38 A)EF45 (9...45 A)AFS40 ... AFS65TF65 (22...67 A)EF65 (20...70 A)AFS80, AFS96TF96 (40...96 A)EF96 (36...100 A)The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(1) Direct mounting ‑ No kit required.CAL4-112‑pole auxiliary contact blockAFS contactorTFEFOverload relay03
—AFS09 ... AFS96 3-pole contactors for safety applicationsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38AFS40AFS52AFS65AFS80AFS96StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 V1000 VRated frequency (without derating)50 / 60 HzConventional free‑air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C35 A35 A35 A50 A50 A50 A105 A105 A105 A130 A130 AWith conductor cross‑sectional area6 mm²6 mm²6 mm²10 mm²10 mm²10 mm²35 mm²35 mm²35 mm²50 mm²50 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C25 A28 A30 A45 A50 A50 A70 A100 A105 A125 A130 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C25 A28 A30 A40 A42 A42 A60 A80 A90 A100 A105 Aθ ≤ 70 °C22 A24 A26 A32 A37 A37 A50 A70 A80 A85 A90 AWith conductor cross‑sectional area4 mm²6 mm²6 mm²10 mm²10 mm²10 mm²25 mm²35 mm²35 mm²50 mm²50 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V9 A12 A18 A26 A33 A40 A40 A53 A65 A80 A96 A380-400 V9 A12 A18 A26 A32 A38 A40 A53 A65 A80 A96 A415 V9 A12 A18 A26 A32 A38 A40 A53 A65 A80 A96 A440 V9 A12 A18 A26 A32 A38 A40 A53 A65 A80 A96 A500 V9.5 A12.5 A15 A23 A28 A33 A35 A45 A55 A65 A80 A690 V7 A9 A10.5 A17 A21 A24 A25 A35 A39 A49 A57 A1000 V25 A30 ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V2.2 kW3 kW4 kW6.5 kW9 kW11 kW11 kW15 kW18.5 kW22 kW25 kW380-400 V4 kW5.5 kW7.5 kW11 kW15 kW18.5 kW18.5 kW22 kW30 kW37 kW45 kW415 V4 kW5.5 kW9 kW11 kW15 kW18.5 kW22 kW30 kW37 kW45 kW55 kW440 V4 kW5.5 kW9 kW15 kW18.5 kW22 kW22 kW30 kW37 kW45 kW55 kW500 V5.5 kW7.5 kW9 kW15 kW18.5 kW22 kW22 kW30 kW37 kW45 kW55 kW690 V5.5 kW7.5 kW9 kW15 kW18.5 kW22 kW22 kW30 kW37 kW45 kW55 kW1000 V35 kW40 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category(without thermal overload relay Ue 400 V 50/60 Hz - θ ≤ 40 °C)Ie / Rated operational current AC-8a12 A16 A22 A30 A40 A50 A53 A70 A85 A105 A120 ARated operational power AC-8a5.5 kW7.5 kW11 kW15 kW20 kW25 kW25 kW37 kW45 kW55 kW65 kWShort‑circuit protection device for contactorswithout thermal overload relay Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse25 A32 A32 A50 A63 A63 A100 A125 A160 A160 A200 ARated short-time withstand current Icw1 s 300 A300 A300 A700 A700 A700 A1000 A1000 A1000 A1200 A1200 Aat 40 °C ambient temperature,in free air from a cold state10 s150 A150 A150 A350 A350 A350 A600 A600 A600 A780 A780 A30 s80 A80 A80 A225 A225 A225 A350 A350 A350 A450 A450 A1 min60 A60 A60 A150 A150 A150 A250 A250 A250 A300 A300 A15 min35 A35 A35 A50 A50 A50 A110 A110 A110 A140 A140 AMaximum breaking capacitycos φ = 0.45at 440 V250 A250 A250 A500 A500 A500 A950 A950 A950 A1150 A1150 Aat 690 V106 A106 A106 A200 A200 A200 A600 A600 A600 A750 A750 APower dissipation per poleIe / AC-10.8 W1 W1.2 W1.8 W2.4 W2.4 W3 W6.3 W7 W7.6 W8.2 WIe / AC-30.1 W0.2 W0.35 W0.6 W0.9 W1.3 W1 W1.7 W2.7 W3 W4.5 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-2, AC-4300 cycles/h150 cycles/hB10dCalculated for 50% of the rated current value Ie at AC-3 / 400 V1.3 million operating cycles(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices". ABB MOTOR PROTECTION AND CONTROL 3/1171SBC100307S0201 - Rev. A03
3/118ABB MOTOR PROTECTION AND CONTROL1SBC100309S0201 —AFS09 ... AFS96 3-pole contactors for safety applicationsTechnical dataMain pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38AFS40AFS52AFS65AFS80AFS96StandardsUL 60947-4-1, CSA-C22.2 No. 60947-4-1Maximum operational voltage600 VNEMA size000‑1‑‑2‑‑3‑NEMA continuous amp ratingThermal current9 A18 A‑27 A‑‑45 A‑‑90 A‑NEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 1/3 hp1 hp‑2 hp‑‑3 hp‑‑‑‑230 V AC 1 hp2 hp‑3 hp‑‑7.5 hp‑‑‑‑NEMA maximum horse power ratings 3-phase, 60 Hz200 V AC1-1/2 hp3 hp‑7-1/2 hp‑‑10 hp‑‑25 hp‑230 V AC1-1/2 hp3 hp‑7-1/2 hp‑‑15 hp‑‑30 hp‑460 V AC 2 hp5 hp‑10 hp‑‑25 hp‑‑50 hp‑575 V AC 2 hp5 hp‑10 hp‑‑25 hp‑‑50 hp‑UL / CSA general use rating600 V AC25 A28 A30 A45 A50 A50 A60 A80 A90 A105 A115 AWith conductor cross‑sectional areaAWG 10 AWG 10 AWG 10 AWG 8AWG 8AWG 8AWG 6AWG 4AWG 3AWG 2AWG 21 pole80 V DC 25 A28 A30 A45 A50 A50 A60 A80 A90 A105 A115 A2 poles in serie160 V DC 25 A28 A30 A45 A50 A50 A60 A80 A90 A105 A115 A3 poles in serie240 V DC 25 A28 A30 A45 A50 A50 A60 A80 A90 A105 A115 AWith conductor cross‑sectional areaAWG 10 AWG 10 AWG 10 AWG 8AWG 8AWG 8AWG 6AWG 4AWG 3AWG 2AWG 2UL / CSA maximum 1-phase motor ratingFull load current120 V AC 13.8 A16 A20 A24 A24 A24 A34 A34 A56 A80 A80 A240 V AC 10 A12 A17 A17 A28 A28 A40 A50 A68 A68 A88 AHorse power rating120 V AC 3/4 hp1 hp1-1/2 hp2 hp2 hp2 hp3 hp3 hp5 hp7-1/2 hp 7-1/2 hp240 V AC1-1/2 hp2 hp3 hp3 hp5 hp5 hp7-1/2 hp10 hp15 hp15 hp20 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 7.8 A11 A17.5 A25.3 A32.2 A32.2 A32.2 A48.3 A62.1 A78.2 A92 A220-240 V AC 6.8 A9.6 A15.2 A22 A28 A28 A42 A54 A68 A80 A80 A440-480 V AC 7.6 A11 A14 A21 A27 A34 A40 A52 A65 A77 A77 A550-600 V AC 9 A11 A17 A22 A27 A32 A41 A52 A62 A77 A77 AHorse power rating (1)200-208 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp10 hp15 hp20 hp25 hp30 hp220-240 V AC 2 hp3 hp5 hp7-1/2 hp10 hp10 hp15 hp20 hp25 hp30 hp30 hp440-480 V AC 5 hp7-1/2 hp10 hp15 hp20 hp25 hp30 hp40 hp50 hp60 hp60 hp550-600 V AC7-1/2 hp10 hp15 hp20 hp25 hp30 hp40 hp50 hp60 hp75 hp75 hpUL / CSA - DC motor starting - 3 poles in seriesFull Load Amps 125 V DC 9.5 A13.2 A17 A25 A25 A25 A40 A58 A76 A76 A110 A250 V DC 8.5 A12.2 A12.2 A20 A29 A29 A38 A55 A72 A89 A106 AHorse power rating 125 V DC 1 hp1-1/2 hp 2 hp3 hp3 hp3 hp5 hp7-1/2 hp10 hp10 hp15 hp250 V DC 2 hp3 hp3 hp5 hp7-1/2 hp 7-1/2 hp10 hp15 hp20 hp25 hp30 hpShort‑circuit protection device for contactorswithout thermal overload relay ‑ Motor protection excludedHigh fault current100 kAFuse rating30 A60 A100 A150 A200 AFuse type, 600 VJMaximum electrical switching frequencyFor general use 600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".03
ABB MOTOR PROTECTION AND CONTROL 3/1191SBC100310S0201 - Rev. A —AFS09 ... AFS96 3-pole contactors for safety applicationsTechnical dataGeneral technical dataContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38Rated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environments A and BAmbient air temperature close to contactorOperationFitted with thermal overload relay-40 ... +60 °CWithout thermal overload relay-40 ... +70 °CStorage-60 ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 million operating cyclesMaximum switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionB2AAB1C2C1A30 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstandacc. to IEC 60068-2-65 ... 300 Hz4 g Closed position / 2 g Open positionMounting characteristics and conditions for useContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4 Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally03
3/120ABB MOTOR PROTECTION AND CONTROL1SBC100491S0201 - Rev. A —AFS09 ... AFS38 3-pole contactors for safety applicationsTechnical dataMagnet system characteristics for AFS09 ... AFS38 contactors - AC / DC operatedContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38Coil operating limits acc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyat θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max at θ ≤ 70 °C 0.85 x Uc min ... Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 250 V ACCoil consumptionAverage pull‑in value50 VAAverage holding value2.2 VA / 2 WDC control voltageRated control circuit voltage Uc20 ... 250 V DCCoil consumptionAverage pull‑in value50 W Average holding value2 WPLC‑output controlAFS..-30-22-11 not suitable for direct control by PLC-output.Drop‑out voltage≤ 60 % Uc min.Operating timeBetween coil energization and:N.O. contact closing40 ... 95 msN.C. contact opening38 ... 90 msBetween coil de‑energization and:N.O. contact opening11 ... 95 ms (1)N.C. contact closing13 ... 98 ms(1) AFS09 ... AFS38 ≤ 35 ms for 20 °C ≤ θ ≤ 70 °CMagnet System Characteristics for AFS09Z ... AFS38Z contactors 24V DC operated - designed for PLC - coil 30Contactor typesDC operatedAFS09ZAFS12ZAFS16ZAFS26ZAFS30ZAFS38ZCoil operating limits acc. to IEC 60947-4-1DC supplyat θ ≤ 60 °C 0.85 ... 1.1 x Uc at θ ≤ 70 °C UcDC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull‑in value6 W Average holding value1.7 WPLC‑output control≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detection Drop‑out voltage≤ 60 % Uc min.Operating timeBetween coil energization and:N.O. contact closing27 ... 53 msN.C. contact opening20 ... 35 msBetween coil de‑energization and:N.O. contact opening17 ... 29 ms N.C. contact closing22 ... 57 ms03
ABB MOTOR PROTECTION AND CONTROL 3/1211SBC100490S0201 - Rev. A —AFS40 ... AFS96 3-pole contactors for safety applicationsTechnical dataGeneral technical dataContactor typesAC / DC operatedAFS40AFS52AFS65AFS80AFS96Rated insulation voltage Uiacc. to IEC 60947-4-1690 V1000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kV8 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environments A and BAmbient air temperature close to contactorOperationFitted with thermal overload relay-40...+70 °CWithout thermal overload relay-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 million operating cyclesMaximum switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionB2AAB1C2C1A25 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstandacc. to IEC 60068-2-65 ... 300 Hz3 g Closed position / 3 g Open positionMagnet system characteristics for AFS40 ... AFS96 contactors - AC / DC operatedContactor typesAC / DC operatedAFS40AFS52AFS65AFS80AFS96Coil operating limits acc. to IEC 60947-4-1AC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max.DC supplyat θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 250 V ACCoil consumptionAverage pull‑in value25 VA40 VAAverage holding value4 VA / 2 WDC control voltageRated control circuit voltage Uc20 ... 250 V DCCoil consumptionAverage pull‑in value25 W40 WAverage holding value2 WPLC‑output controlAFS..-30-22-11 not suitable for direct control by PLC-output.Drop‑out voltage≤ 60 % Uc min.Operating timeBetween coil energization and:N.O. contact closing42 ... 100 msN.C. contact opening38 ... 95 msBetween coil de‑energization and:N.O. contact opening17 ... 100 msN.C. contact closing19 ... 105 msMounting characteristics and conditions for useContactor typesAC / DC operatedAFS40AFS52AFS65AFS80AFS96Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4 Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mm35 x 15 mmBy screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally03
3/122 ABB MOTOR PROTECTION AND CONTROL1SBC100311S0201 Connecting characteristicsContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38AFS40AFS52AFS65AFS80AFS96Main terminals Screw terminals with cable clampScrew terminals with double connector 2 x (9.3 width x 7.9/10.3 depth)Screw terminals with double connector 2 x (12.4 width x 9.3/11.1 depth)Connection capacity (min. ... max.)Main conductors (poles)Rigid Solid (≤ 4 mm²)1 x1 ... 6 mm²2.5 ... 10 mm²6 ... 35 mm²6 ... 70 mm²Stranded (6 > 6 mm²)2 x1 ... 6 mm²2.5 ... 10 mm²6 ... 35 mm²6 ... 50 mm²Flexible with non insulated ferrule1 x0.75 ... 6 mm²1.5 ... 10 mm²4 ... 35 mm²6 ... 50 mm²2 x0.75 ... 6 mm²1.5 ... 10 mm²4 ... 35 mm²6 ... 50 mm²Flexible with insulated ferrule1 x0.75 ... 4 mm²1.5 ... 10 mm²4 ... 35 mm²6 ... 50 mm²2 x0.75 ... 2.5 mm²1.5 ... 4 mm²4 ... 35 mm²6 ... 50 mm²L6Bars or lugsL <9.6 mm12.5 mm9.2 mm12.2 mmConnection capacity acc. to UL/CSA1 or 2 xAWG 16 ... 10AWG 14 ... 8AWG 10 ... 2AWG 6 ... 1Stripping length10 mm14 mm16 mm17 mmTightening torque1.5 Nm / 13 lb.in2.5 Nm / 22 lb.in4 Nm / 35 lb.in6 Nm / 53 lb.inAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x1 ... 2.5 mm²2 x1 ... 2.5 mm²Flexible with non insulated ferrule1 x0.75 ... 2.5 mm²2 x0.75 ... 2.5 mm²Flexible with insulated ferrule1 x0.75 ... 2.5 mm²2 x0.75 ... 1.5 mm²L6Bars or lugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 xAWG 18 ... 14Stripping length10 mmTightening torqueCoil terminals1.2 Nm / 11 lb.inBuilt‑in auxiliary terminals1.2 Nm / 11 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20IP10Coil terminalsIP20Built‑in auxiliary terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM3.5M4M6M8Screwdriver typeFlat Ø 5.5 / Pozidriv 2Flat Ø 6.5 / Pozidriv 2hexagon socket (s = 4 mm)Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Built‑in auxiliary terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2—AFS09 ... AFS96 3-pole contactors for safety applicationsTechnical data}03
1SBC100312S0201 Built-in auxiliary contacts according to IECContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38AFS40AFS52AFS65AFS80AFS96Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free air thermal current Ith - θ ≤ 40 °C16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz6 A220-240 V 50/60 Hz4 A400-440 V 50/60 Hz3 A500 V 50/60 Hz2 A690 V 50/60 Hz2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC6 A / 144 W48 V DC2.8 A / 134 W72 V DC1 A / 72 W110 V DC0.55 A / 60 W125 V DC0.55 A / 69 W220 V DC0.27 A / 60 W250 V DC0.27 A / 68 W400 V DC0.15 A / 60 W500 V DC0.13 A / 65 W600 V DC0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s100 Afor 0.1 s140 AMinimum switching capacitywith failure rate acc. to IEC 60947-5-412 V / 3 mA10−⁷Non‑overlapping time between N.O. and N.C. contacts≥ 2 msPower dissipation per pole at 6 A0.1 wMaximum electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsacc. to annex L of IEC 60947-5-1Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CAL4 aux. contact blocks) are mechanically linked contacts.Mirror contactsacc. to annex F of IEC 60947-4-1Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CAL4 aux. contact blocks) are mirror contacts.Built-in auxiliary contacts according to UL / CSAContactor typesAC / DC operatedAFS09AFS12AFS16AFS26AFS30AFS38AFS40AFS52AFS65AFS80AFS96Maximum operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt‑ampere making7200 VAAC maximum volt‑ampere breaking720 VADC thermal rated current2.5 ADC maximum volt‑ampere making‑breaking69 VA—AFS09 ... AFS96 3-pole contactors for safety applicationsTechnical data ABB MOTOR PROTECTION AND CONTROL 3/12303
—3-pole contactors for safety applicationsElectrical durabilityElectrical durability for AC-1 utilization category - Ue ≤ 690 VSwitching non‑inductive or slightly inductive loads. The breaking current Ic for AC‑1 is equal to the rated operational current of the load.Ambient temperature and maximum electrical switching frequency: see "Technical data".13579135791591357913579135791357913579159135791010.10.20.30.535101001000235203050200300500226.5AFS09AFS12AFS16AFS26AFS30, AFS38AFS40AFS52AFS65AFS80, AFS96Millions of operatingcyclesBreaking current Ic (A)Example:Ic / AC-1 = 26.5 A – Electrical durability required = 2 millions operating cycles.Using the AC-1 curves above select the AFS26 contactor at intersection "" (26.5 A / 2 millions operating cycles).3/124ABB MOTOR PROTECTION AND CONTROL1SBC100316S0201 - Rev. A03
—3-pole contactors for safety applicationsElectrical durabilityElectrical durability for AC-3 utilization category - Ue ≤ 440 V.Switching cage motors: starting and switching off running motors. The breaking current Ic for AC‑3 is equal to the rated operational current Ie (Ie = motor full load current).Ambient temperature and maximum electrical switching frequency: see "Technical data".1011010010002352030502003005000.20.30.523513579135791357913579135791357915915913579135791.855AFS09AFS12AFS16AFS26AFS40AFS52AFS65AFS30, AFS38AFS80, AFS96Millions of operatingcyclesBreaking current Ic (A)Example:Motor power 30 kW for AC-3 - Ue = 400 V and Ie = 55 A utilization – Electrical durability required = 1.8 million operating cycles.For AC-3: Ic = Ie. Select the AFS65 contactor at intersection "" (55 A / 1.8 million operating cycles) on the curves (AC-3 - Ue ≤ 440 V). ABB MOTOR PROTECTION AND CONTROL 3/1251SBC100317S0201 - Rev. A03
—3-pole contactors for safety applicationsElectrical durabilityElectrical durability for AC-3 utilization category - 440 V < Ue ≤ 690 V. Switching cage motors: starting and switching off running motors. The breaking current Ic for AC‑3 is equal to the rated operational current Ie (Ie = motor full load current).Ambient temperature and maximum electrical switching frequency: see "Technical data".1357913579159135791357913579135791357913579135791011010010002352030502003005000.20.30.5235AFS09AFS12AFS16AFS26AFS30, AFS38AFS40AFS52AFS65AFS80, AFS961.5140Millions of operating cyclesBreaking current Ic (A)3/126ABB MOTOR PROTECTION AND CONTROL1SBC100318S0201 - Rev. A 03
—3-pole contactors for safety applicationsElectrical durabilityElectrical durability for AC-2 or AC-4 utilization category - Ue ≤ 440 V Ambient temperature ≤ 60 °C for AFS09 ... AFS96Switching cage motors: starting, reverse operation and step‑by‑step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keeping in mind that Ie is the motor rated operational current (Ie = motor full-load current).Maximum electrical switching frequency: see "Technical data".3000100010010235203050200300500200050001010.10.0050.010.020.030.050.30.20.52351357913579135791357913579135791357913579AFS12AFS16AFS09AFS26AFS30, AFS38AFS40AFS80, AFS96AFS65AFS52Millions of operatingcyclesBreaking current Ic (A) ABB MOTOR PROTECTION AND CONTROL 3/1271SBC100319S0201 - Rev. A03
3/128ABB MOTOR PROTECTION AND CONTROL1SBC100320S0201 —3-pole contactors for safety applicationsElectrical durabilityElectrical durability for AC-2 or AC-4 utilization category - 440 V < Ue ≤ 690 V Ambient temperature ≤ 60 °C for AFS09 ... AFS96Switching cage motors: starting, reverse operation and step‑by‑step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keaping in mind tha Ie is the motor rated operational current (Ie = motor full load current). Maximum electrical switching frequency: see "Technical data".AFS38AFS40AFS52AFS65AFS80, AFS96AFS30AFS26AFS16AFS12AFS0913579135791010.10.0050.010.020.030.050.20.30.523550001000100102352030502003005002000 30001357913579135791357913579Millions of operatingcyclesBreaking current Ic (A)03
—Notes ABB MOTOR PROTECTION AND CONTROL 3/12903
—AF and EK 4-pole contactors3/132 Overview Ordering details 25 to 125 A AC-13/134 AF09 ... AF38 AC / DC operated3/135 AF09Z ... AF16Z 24 V DC operated designed for PLC3/136 AF09Z ... AF38Z AC / DC operated for specific applications3/137 AF40 ... AF80 AC / DC operated3/138 Contactors and main accessories 160 to 525 A AC-13/139 AF116 ... AF140 AC / DC operated3/140 AF190 ... AF370 AC / DC operated3/141 Contactors and main accessories 3/142 AF116 ... AF140 AC / DC operated - with 1 N.O. + 1 N.C.3/143 AF190 ... AF370 AC / DC operated - with 1 N.O. + 1 N.C.3/144 Contactors and main accessories3/145 AF116 ... AF140 AC / DC operated - with 2 N.O. + 2 N.C. 3/146 AF190 ... AF370 AC / DC operated - with 2 N.O. + 2 N.C. 3/147 Contactors and main accessories 800 to 1000 A AC-13/148 EK550, EK1000 AC operated - with 1 N.O. + 1 N.C.3/149 EK550, EK1000 DC operated - with 2 N.O. + 1 N.C.3/150 EK550, EK1000 AC operated - with 2 N.O. + 2 N.C.3/151 Main accessories3/153 Technical data3/165 Electrical durability3/404 Voltage code table— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R1310 ABB MOTOR PROTECTION AND CONTROL 3/13103
—4-pole contactorsMain accessoriesAuxiliary contact blocksFront mountingSide mountingTimersElectronicInterlocking unitsMechanicalMechanical / ElectricalSurge suppressorsVaristor + RC (AC / DC)IECAC-1 Rated operational current θ ≤ 40 °C, 690 VA25304555701001251602002753504005005258001000UL/CSAGeneral use rating600 VA253045556080105160175230250300350420540—AC / DC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370——AC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000DC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000IECAC-1 Rated operational current690 Vθ ≤ 40 °CA25304555701001251602002753504005005258001000θ ≤ 60 °C (1)A253040456080105145175250300350400425650800θ ≤ 70 °CA22263237507090130160200240290325350575720With conductor cross sectional areamm²46101635355070951502402403002 x 1852 x 2402 x 300Rated operational voltage Ue max.V6906906906906906906906906901000100010001000100010001000(1) θ ≤ 55 °C for EK550, EK1000 contactors CA4-10 (1 x N.O.), CA4-01 (1 x N.C.)CAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11(1 x N.O. + 1 x N.C.)CAL16-11 (1 x N.O. + 1 x N.C.)TEF4-ONTEF4-OFFVM4VM96-4VM19 (for same size contactors)VH800VEM4Built-in surge protectionRC-EH8003/132ABB MOTOR PROTECTION AND CONTROL03
IECAC-1 Rated operational current θ ≤ 40 °C, 690 VA25304555701001251602002753504005005258001000UL/CSAGeneral use rating600 VA253045556080105160175230250300350420540—AC / DC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370——AC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000DC Control supplyTy peAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370EK550EK1000IECAC-1 Rated operational current690 Vθ ≤ 40 °CA25304555701001251602002753504005005258001000θ ≤ 60 °C (1)A253040456080105145175250300350400425650800θ ≤ 70 °CA22263237507090130160200240290325350575720With conductor cross sectional areamm²46101635355070951502402403002 x 1852 x 2402 x 300Rated operational voltage Ue max.V6906906906906906906906906901000100010001000100010001000(1) θ ≤ 55 °C for EK550, EK1000 contactors CA4-10 (1 x N.O.), CA4-01 (1 x N.C.)CAL4-11 (1 x N.O. + 1 x N.C.)CAL19-11 (1 x N.O. + 1 x N.C.)CAL16-11 (1 x N.O. + 1 x N.C.)TEF4-ONTEF4-OFFVM4VM96-4VM19 (for same size contactors)VH800VEM4Built-in surge protectionRC-EH8001SBC101569S0201 - Rev. EABB MOTOR PROTECTION AND CONTROL 3/13303
—AF09 ... AF38 4-pole contactors25 to 55 A AC-1AC / DC operatedAF09 ... AF38 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These contactors are of the block type design with 4 main poles. • control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening.• built-in surge suppression • add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main poles252524...6020...60(1)0 0AF09-40-00-111SBL137201R11000.27048...13048...1300 0AF09-40-00-121SBL137201R12000.270100...250100...2500 0AF09-40-00-131SBL137201R13000.270250...500250...5000 0AF09-40-00-141SBL137201R14000.310303024...6020...60(1)0 0AF16-40-00-111SBL177201R11000.27048...13048...1300 0AF16-40-00-121SBL177201R12000.270100...250100...2500 0AF16-40-00-131SBL177201R13000.270250...500250...5000 0AF16-40-00-141SBL177201R14000.310454524...6020...60(1)0 0AF26-40-00-111SBL237201R11000.36048...13048...1300 0AF26-40-00-121SBL237201R12000.360100...250100...2500 0AF26-40-00-131SBL237201R13000.360250...500250...5000 0AF26-40-00-141SBL237201R14000.400555524...6020...60(1)0 0AF38-40-00-111SBL297201R11000.36048...13048...1300 0AF38-40-00-121SBL297201R12000.360100...250100...2500 0AF38-40-00-131SBL297201R13000.360250...500250...5000 0AF38-40-00-141SBL297201R14000.4002 N.O. + 2 N.C. main poles252524...6020...60(1)0 0AF09-22-00-111SBL137501R11000.27048...13048...1300 0AF09-22-00-121SBL137501R12000.270100...250100...2500 0AF09-22-00-13 1SBL137501R13000.270250...500250...5000 0AF09-22-00-141SBL137501R14000.310303024...6020...60(1)0 0AF16-22-00-111SBL177501R11000.27048...13048...1300 0AF16-22-00-121SBL177501R12000.270100...250100...2500 0AF16-22-00-131SBL177501R13000.270250...500250...5000 0AF16-22-00-141SBL177501R14000.310454524...6020...60(1)0 0AF26-22-00-111SBL237501R11000.36048...13048...1300 0AF26-22-00-121SBL237501R12000.360100...250100...2500 0AF26-22-00-131SBL237501R13000.360250...500250...5000 0AF26-22-00-141SBL237501R14000.400555524...6020...60(1)0 0AF38-22-00-111SBL297501R11000.36048...13048...1300 0AF38-22-00-121SBL297501R12000.360100...250100...2500 0AF38-22-00-13 1SBL297501R13000.360250...500250...5000 0AF38-22-00-141SBL297501R14000.400(1) AF..-40-..-11 and AF..-22-..-11 not suitable for direct control by PLC-output.AF09, AF16AF26, AF3845 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC35 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC1SBC101095F0014AF09-40-001SBC101097F0014AF26-40-00Main dimensions mm, inches1SBC101375S0201 - Rev. C3/134 ABB MOTOR PROTECTION AND CONTROL03
1SBC101529V0014AF09Z-40-00—AF09Z ... AF16Z 4-pole contactors25 to 30 A AC-124 V DC operated designed for PLCAF09Z ... AF16Z 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These contactors are of the block type design with 4 main poles.• control circuit: 24 V DC operated with electronic coil interface allowing low holding consumption up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc Auxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV DCkg4 N.O. main poles2525240 0AF09Z-40-00-301SBL136201R30000.4303030240 0AF16Z-40-00-301SBL176201R30000.4302 N.O. + 2 N.C. main poles2525240 0AF09Z-22-00-301SBL136501R30000.4303030240 0AF16Z-22-00-301SBL176501R30000.430Note: AF..Z contactors with 24 V DC control voltage need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.45 1.77"80 3.15"6 0.24"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC97 3.82"91 3.58" AF09Z, AF16ZContactors AF..Z-...-30, contactor relays NFZ...-30 and accessoriesSchütze AF..Z-...-30, Hilfsschütze NFZ...-30 und ZubehörContacteurs AF..Z-...-30, contacteurs auxiliaires NFZ...-30 et accessoiresKontaktorer AF..Z-...-30, reläkontaktorer NFZ...-30 och tillbehörContattori AF..Z-...-30, contattori ausiliari NFZ...-30 e accessori Contactores AF..Z-...-30, contactores auxiliares NFZ...-30 y accesoriosAF..Z-...-30,NFZ...-30NFZ...-30, 1SBC101053M6801 - 01/18AF09Z...38Z-..-..-30, NFZ22E-30...NFZ80E-30, CA4, CAL4, LDC4Operating instructionsBetriebsanleitungNotice d'instructionInstruktionIstruzioni tecnicheInstrucciones de empleoABB France3, rue Jean Perrin69680 Chassieu / Francewww.abb.com/lowvoltageZ-...-30,35mm EN/EC 607155.5 0.22"91 3.58"97 3.82" 5.5 0.22"10 0.39"35mm EN/EC 607155.5 0.22"91 3.58"130.5 5.14"5.5 0.22"10 0.39"43 1.69"CLIC !4CLIC !2 AmminchNFZ44E...NFZ80E-30 AF09Z...16Z-30-22-30130,5 5.14"AF26Z...38Z-30-22-30AF26Z...38Z-30-11-30139,5 5.49"131,5 5.18" Bmminch91 3.58"100 3.94"100 3.94" Amm inch97 3.82" B mm inch91 3.58"NFZ22E...NFZ40E-30AF09Z...16Z-...-30 AF26Z...38Z-...-30 3-pole106 4.17"100 3.94"45 1,77" 80 3.15" 6 0.24" 2 0.08"2 0.08" AF09Z...38Z-...-30, NFZ22E...NFZ80E-30Acc. to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, min. enclosure for : AF09Z...AF16Z-...-30, NFZ...-30, : 180 x 130 x 175 mmAF26Z...38Z-30-...-30 3-pole : 255 x 180 x 175 mm35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCpozidriv N° 2M 3,51,2 N.mM 3,51,5 N.m2 x1...62 x1...2,5mm²mm²2 x0,75...62 x0,75...2,5 L < 8L < 9,6Ø 5,5Ø 5,5AF09Z...16Z-...-303 & 4-polemm²2 x 0,75...2,51 x 0,75...4AF09Z ... 38Z-...-30NFZ...-30NFZ...-30AF09Z... 38Z-30-22-30AF26Z... 38Z-30-11-30 M 3,51,2 N.mØ 5,5AF26Z...38Z-...-303-poleM 42,5 N.mØ 6,52 x0,75...2,52 x1...2,52 x2,5...102 x1,5...102 x 0,75...1,51 x 0,75... 2,52 x 0,75....1,51 x 0,75... 2,52 x 1,5...41 x 1,5...10L < 12,5 L < 8L < 9,6LLL = 10L = 14L = 10L = 10mmAF09Z...16Z-30-10-30AF09Z...16Z-30-01-30_____LHmmmm-Uc= 24VDCA1A2NFZ...-30AF09Z...38Z-..-30+AF26/AF30/AF38 AF26/AF30/AF38 AF26/AF30/AF38max Fusemax Fuse60A/RK5Circuit BreakerT4V250 + TM250Circuit BreakerXT1H125 + TM100Circuit BreakerXT2V125 + TM10060A/J52535-654265100AF26According to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, for use on a circuit capable of delivering not more than the max. symmetrical amperes at the max. voltage shown in the table below. WARNING : if opening of BCP, controller shall be examined and replaced if damaged.AF30AF38max Fuse100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)480V (kA)600V (kA)Max Short-circuit at100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)Max Short-circuit at480V, 600V(kA)NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30NFZ31E-30, NFZ22E-30AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30 + max 4 aux contacts / 2NCCA4-04CA4-04+ max 4 aux contacts / 3NC Pos. 3Pos. 2Pos. 1Pos. 4NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30+ max 4 aux contacts / 4NC AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30NFZ31E-30, NFZ22E-30 + max 4 aux contacts / 3NC CA4-04+ max 1 x CAL4-11+ max 1 x CAL4-11Pos. 5Pos. 1 ± 30°+30°-30°AF26Z...38Z-30-11-30AF26Z...38Z-30-11-3035 mm EN/IEC 60715Assembly - Anbau - Montage - MonteringMontaggio - Montaje --22Disassembly - AbbauDémontage - DemonteringSmontaggio - Desmontaje-1LDC4NFZ...-30, AF09Z...38Z-..-30 + LDC4UcA1A2A1A2NFZ...-30,AF09Z...38Z-..-30123UcA1A2NFZ...-30,AF09Z...38Z-..-30A1UcA2TF42AF26Z...38ZCAL4-11AF26Z...38Z-30-11AF26Z...38Z-30-22-30AF09Z...16Z-30-22-30NFZ44E...80E-30TF42AF09Z...38ZAF09Z...16Z-30-01-30AF09Z...16Z-30-10-30AF09Z..16Z-40-00-30AF09Z..16Z-22-00-30NFZ22E ...40E-30CA4 -10 -01CA4-40/22/31/04 CAL4-11 CAL4-11AF09Z ... 38Z-..-..-30AF26Z...38Z-30-00-30Circuit-Breaker XT2V125 + TM60max Fuse30A/RK530A/J5100AF09, AF1210AF16AF09/12/16max Fuse60A/RK5 60A/J5100TF42Main dimensions mm, inches1SBC100329S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/13503
1SBC101095F0014AF09Z-40-001SBC101097F0014AF26Z-40-00—AF09Z ... AF38Z 4-pole contactors25 to 55 A AC-1AC / DC operated for specific applicationsAF09Z ... AF38Z 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These contactors are of the block type design with 4 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC - can manage large control voltage variations -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main poles2525-12...200 0AF09Z-40-00-201SBL136201R20000.31024...6020...600 0AF09Z-40-00-211SBL136201R21000.31048...13048...1300 0AF09Z-40-00-221SBL136201R22000.310100...250 100...2500 0AF09Z-40-00-231SBL136201R23000.3103030-12...200 0AF16Z-40-00-201SBL176201R20000.31024...6020...600 0AF16Z-40-00-211SBL176201R21000.31048...13048...1300 0AF16Z-40-00-221SBL176201R22000.310100...250 100...2500 0AF16Z-40-00-231SBL176201R23000.3104545-12...200 0AF26Z-40-00-201SBL236201R20000.40024...6020...600 0AF26Z-40-00-211SBL236201R21000.40048...13048...1300 0AF26Z-40-00-221SBL236201R22000.400100...250 100...2500 0AF26Z-40-00-231SBL236201R23000.4005555-12...200 0AF38Z-40-00-201SBL296201R20000.40024...6020...600 0AF38Z-40-00-21 1SBL296201R21000.40048...13048...1300 0AF38Z-40-00-221SBL296201R22000.400100...250 100...2500 0AF38Z-40-00-23 1SBL296201R23000.4002 N.O. + 2 N.C. main poles2525-12...200 0AF09Z-22-00-201SBL136501R20000.31024...6020...600 0AF09Z-22-00-211SBL136501R21000.31048...13048...1300 0AF09Z-22-00-221SBL136501R22000.310100...250 100...2500 0AF09Z-22-00-231SBL136501R23000.3103030-12...200 0AF16Z-22-00-201SBL176501R20000.31024...6020...600 0AF16Z-22-00-211SBL176501R21000.31048...13048...1300 0AF16Z-22-00-221SBL176501R22000.310100...250 100...2500 0AF16Z-22-00-231SBL176501R23000.3104545-12...200 0AF26Z-22-00-201SBL236501R20000.40024...6020...600 0AF26Z-22-00-211SBL236501R21000.40048...13048...1300 0AF26Z-22-00-221SBL236501R22000.400100...250 100...2500 0AF26Z-22-00-231SBL236501R23000.4005555-12...200 0AF38Z-22-00-201SBL296501R20000.40024...6020...600 0AF38Z-22-00-211SBL296501R21000.40048...13048...1300 0AF38Z-22-00-221SBL296501R22000.400100...250 100...2500 0AF38Z-22-00-231SBL296501R23000.400Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.AF09Z, AF16ZAF26Z, AF38Z45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC35 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inches1SBC101376S0201 - Rev. B3/136 ABB MOTOR PROTECTION AND CONTROL03
1SBC101987S0201 - Rev. C ABB MOTOR PROTECTION AND CONTROL 3/1376 0.24"119.5 4.70"70 2.76"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715113.5 4.47"5.5 0.22"AF40, AF526 0.24"119.5 4.70"90 3.54"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715AF80—AF40 ... AF80 4-pole contactors70 to 125 A AC-1AC / DC operatedAF40 ... AF80 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These contactors are of the block type design with 4 main poles. • control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltages ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request). • built-in surge suppression • add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operationalGeneral use rating600 V ACcurrentθ ≤ 40 °CAC-1AAV 50/60 HzV DCkg4 N.O. main poles706024...6020...600 0AF40-40-00-111SBL347201R11001.21048...13048...1300 0AF40-40-00-121SBL347201R12001.210100...250100...2500 0AF40-40-00-131SBL347201R13001.160250...500250...5000 0AF40-40-00-141SBL347201R14001.1601008024...6020...600 0AF52-40-00-111SBL367201R11001.21048...13048...1300 0AF52-40-00-121SBL367201R12001.210100...250100...2500 0AF52-40-00-131SBL367201R13001.160250...500250...5000 0AF52-40-00-141SBL367201R14001.16012510524...6020...600 0AF80-40-00-111SBL397201R11001.49048...13048...1300 0AF80-40-00-121SBL397201R12001.490100...250100...2500 0AF80-40-00-131SBL397201R13001.440250...500250...5000 0AF80-40-00-141SBL397201R14001.4402 N.O. + 2 N.C. main poles706024...6020...600 0AF40-22-00-111SBL347501R11001.21048...13048...1300 0AF40-22-00-121SBL347501R12001.210100...250100...2500 0AF40-22-00-131SBL347501R13001.160250...500250...5000 0AF40-22-00-141SBL347501R14001.16012510524...6020...600 0AF80-22-00-111SBL397501R11001.49048...13048...1300 0AF80-22-00-121SBL397501R12001.490100...250100...2500 0AF80-22-00-13 1SBL397501R13001.440250...500250...5000 0AF80-22-00-141SBL397501R14001.440For control by PLC-output, use R A4 interface relay.AF40-40-001SBC101045V0014AF80-40-001SBC101048V0014Main dimensions mm, inches03
3/138 ABB MOTOR PROTECTION AND CONTROL—AF09 ... AF80 4-pole contactorsContactors and main accessoriesVEM4 mechanical and electrical interlock set Including: -VM4 mechanical interlock unit with 2 fixing clips -VE4 electrical inlerlock block with A2-A2 connectionAF09...AF52 contactorsAF09...AF80 contactorsAF09...AF38 contactorsCAL4-112-pole auxiliary contact blockCA41-pole auxiliary contact blockVE4VM..Mechanical interlock unitCA41-pole auxiliary contact blockCA41-pole auxiliary contact blockCAL4-112-pole auxiliary contact blockCA44-pole auxiliary contact blockFixing clipsC AT4 -112-pole auxiliary contact and A1/A2 coil terminal blockBX4-CAProtective coverTEF4Electronic timerBX4-CAProtective coverBX4-CAProtective coverBX4Protective coverMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMain polesBuilt-in auxiliary contactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerMechanical latching unitElectrical and Auxiliary contact blocksmechanical interlock set1-pole CA4(between 2 contactors)2-pole CAL4-11 2-pole CAT4-114-pole CA4TEF4 WA4 (4)VEM4Left sideRight sideAF09(Z) ... AF38(Z)AF09 ... AF164 00 0 (1)4 max.or 1or 1or 1or 1–+1–AF26 ... AF384 00 0 (2)2 max.or 1–or 1or 1–+1+ 13 max.––––+ 1 (5)+1or 1AF09 ... AF382 20 0 (2)4 max.or 1or 1or 1or 1–+1–2 max.or 1–or 1or 1–+1+ 1AF09Z ... AF16Z 24 V DC designed for PLC - coil 30AF09Z ... AF16Z4 00 0 (1)4 max.–or 1or 1–– (5)or1+ 12 max.––or 1–– (5)+1or 1–––1––+1+ 1AF09Z ... AF16Z2 20 0 (2)4 max.–or 1or 1––or1+ 12 max.––or 1––+1or 1–––1––+1+ 1AF40 ... AF80AF40 ... AF524 00 04 max.or 1or 1or 1or 1–+1+ 1AF804 00 04 max.–or 1or 1or 1–+1+ 1AF402 20 0 (3)4 max.or 1or 1or 1or 1–+1–4 max.–or 1or 1or 1–+1+ 1AF802 20 0 (3)4 max.–or 1or 1or 1–+1+ 1(1) Including add-on contacts: 4 N.C. auxiliary contacts max. on positions 1, 2, 3, 4 and 3 N.C. auxiliary contacts max. on positions 1 ±30°, 5.(2) Including add-on contacts: 3 N.C. auxiliary contacts max. on positions 1, 2, 3, 4 and 2 N.C. auxiliary contacts max. on positions 1 ±30°, 5.(3) Including add-on contacts: 2 N.C. auxiliary contacts max. on positions 1, 1 ±30°, 2, 3, 4, 5.(4) Use WA4 for AF09...AF65 and WA4-96 for AF80. Accept 1-pole CA4 auxiliary contacts (1 block on each side of the mechanical latch) in respect to the total number of built-in or additional N.C. auxiliary contacts.For WA4 accessory use with contactors coil 30, please consult your ABB local sales organization.(5) VEM4 not suitable for AF..Z contactors with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30). Use VM4 side-mounted mechanical interlock unit.WA4Mechanical latching unitA2-A2 connection(without coil terminal block)X1SBC101392S0201 - Rev. C03
1SFC101197C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/139—AF116 ... AF140 4-pole contactors160 to 200 A AC-1AC / DC operatedAF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 350 V DC. These contactors are of the block type design with 4 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main polesFor connection with built-in cable clamps16016024...60 20...600 0AF116-40-00-111SFL427101R11002.25048...13048...1300 0AF116-40-00-121SFL427101R12002.250100...250 100...2500 0AF116-40-00-131SFL427101R13002.250250...500 250...5000 0AF116-40-00-141SFL427101R14002.25020017524...60 20...600 0AF140-40-00-111SFL447101R11002.25048...13048...1300 0AF140-40-00-121SFL447101R12002.250100...250 100...2500 0AF140-40-00-131SFL447101R13002.250250...500 250...5000 0AF140-40-00-141SFL447101R14002.250With bar connections16016024...60 20...600 0AF116-40-00B-111SFL427102R11002.15048...13048...1300 0AF116-40-00B-121SFL427102R12002.150100...250 100...2500 0AF116-40-00B-131SFL427102R13002.150250...500 250...5000 0AF116-40-00B-141SFL427102R14002.15020017524...60 20...600 0AF140-40-00B-111SFL447102R11002.15048...13048...1300 0AF140-40-00B-121SFL447102R12002.150100...250 100...2500 0AF140-40-00B-131SFL447102R13002.150250...500 250...5000 0AF140-40-00B-141SFL447102R14002.150(1) For other auxiliary contacts arrangements, please contact your ABB local organization.SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"120 4.72"128 5.04"SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"120 4.72"128 5.04"ASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"128 5.04"120 4.72"ASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"128 5.04"120 4.72"AF116, AF140-40-00AF116, AF140-40-00BAF140-40-00AF140-40-00B1SFC101158V00011SFC101193V0001Main dimensions mm, inches03
1SFC101198C0201 - Rev. B3/140ABB MOTOR PROTECTION AND CONTROL—AF190 ... AF370 4-pole contactors275 to 525 A AC-1AC / DC operatedAF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 440 V DC. These contactors are of the block type design with 4 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). •built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main poles27523024...60 20...600 0AF190-40-00-111SFL487102R11003.90048...13048...1300 0AF190-40-00-121SFL487102R12003.900100...250 100...2500 0AF190-40-00-131SFL487102R13003.900250...500 250...5000 0AF190-40-00-141SFL487102R14003.90035025024...60 20...600 0AF205-40-00-111SFL527102R11003.90048...13048...1300 0AF205-40-00-121SFL527102R12003.900100...250 100...2500 0AF205-40-00-131SFL527102R13003.900250...500 250...5000 0AF205-40-00-141SFL527102R14003.90040030024...60 20...600 0AF265-40-00-111SFL547102R11006.36048...13048...1300 0AF265-40-00-121SFL547102R12006.360100...250 100...2500 0AF265-40-00-131SFL547102R13006.360250...500 250...5000 0AF265-40-00-141SFL547102R14006.36050035024...60 20...600 0AF305-40-00-111SFL587102R11006.36048...13048...1300 0AF305-40-00-121SFL587102R12006.360100...250 100...2500 0AF305-40-00-131SFL587102R13006.360250...500 250...5000 0AF305-40-00-141SFL587102R14006.36052542024...60 20...600 0AF370-40-00-111SFL607102R11006.36048...13048...1300 0AF370-40-00-121SFL607102R12006.360100...250 100...2500 0AF370-40-00-131SFL607102R13006.360250...500 250...5000 0AF370-40-00-141SFL607102R14006.360(1) For other auxiliary contacts arrangements, please contact your ABB local organization.Aø 8.5 0.33"35 1.38"196 7.72"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION A-A 140 5.51"152.5 6.00"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A183.75 7.23"AF190, AF205AF265, AF305, AF370AF205-40-00AF370-40-001SFC101160V00011SFC101197V0001Main dimensions mm, inches03
—AF116 ... AF370 4-pole contactors Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Auxiliary contact blocksMechanical interlock units(between two contactors)CAL19-11 (3)CAL19-11B (3)AF116 ... AF3704 00 02 x CAL19-11+ 2 x CAL19-11B–AF116 ... AF3704 00 02 x CAL19-11 (1)+ 2 x CAL19-11B (1)+ VM... (2)(1) Total number of auxiliary contact blocks for the two contactors. (2) Interlock type, according to the contactor ratings (see "Accessories").(3) The CEL19 auxiliary contact blocks can replace the CAL19-11 and CAL19-11B. Though, no auxiliary contact block can be mounted outside the CEL19.AF contactorwith bar connectionsCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockVM Mechanical interlockLT Terminal shroudAF contactorwith built-in cable clamps ABB MOTOR PROTECTION AND CONTROL 3/1411SFC101203C0201 - Rev. A03
1SFC101199C0201 - Rev. B3/142ABB MOTOR PROTECTION AND CONTROL—AF116 ... AF140 4-pole contactors160 to 200 A AC-1AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 350 V DC. These contactors are of the block type design with 4 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). •built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main polesFor connection with built-in cable clamps16016024...60 20...601 1AF116-40-11-11 1SFL427101R11112.27048...13048...1301 1AF116-40-11-121SFL427101R12112.270100...250 100...2501 1AF116-40-11-131SFL427101R13112.270250...500 250...5001 1AF116-40-11-141SFL427101R14112.27020017524...60 20...601 1AF140-40-11-111SFL447101R11112.27048...13048...1301 1AF140-40-11-121SFL447101R12112.270100...250 100...2501 1AF140-40-11-131SFL447101R13112.270250...500 250...5001 1AF140-40-11-141SFL447101R14112.270With bar connections16016024...60 20...601 1AF116-40-11B-11 1SFL427102R11112.17048...13048...1301 1AF116-40-11B-121SFL427102R12112.170100...250 100...2501 1AF116-40-11B-131SFL427102R13112.170250...500 250...5001 1AF116-40-11B-141SFL427102R14112.17020017524...60 20...601 1AF140-40-11B-111SFL447102R11112.17048...13048...1301 1AF140-40-11B-121SFL447102R12112.170100...250 100...2501 1AF140-40-11B-131SFL447102R13112.170250...500 250...5001 1AF140-40-11B-141SFL447102R14112.170(1) For other auxiliary contacts arrangements, please contact your ABB local organization.SECTION A-A55.5 0.22"19.5 4.96"30 1.18"A150 5.91"10 0.39"120 4.72"128 5.04"SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"10 0.39"120 4.72"128 5.04"ASECTION A-A55.5 2.18"19.5 0.77"150 5.91"30 1.18"10 0.39"128 5.04"120 4.72"ASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"10 0.39"128 5.04"120 4.72"AF116, AF140-40-11AF116, AF140-40-11BAF140-40-11AF140-40-11B1SFC101154V00011SFC101192V0001Main dimensions mm, inches03
1SFC101200C0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/143—AF190 ... AF370 4-pole contactors275 to 525 A AC-1AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsAF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 440 V DC. These contactors are of the block type design with 4 main poles.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). •built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main poles27523024...60 20...601 1AF190-40-11-111SFL487102R11113.92048...13048...1301 1AF190-40-11-121SFL487102R12113.920100...250 100...2501 1AF190-40-11-131SFL487102R13113.920250...500 250...5001 1AF190-40-11-141SFL487102R14113.92035025024...60 20...601 1AF205-40-11-111SFL527102R11113.92048...13048...1301 1AF205-40-11-121SFL527102R12113.920100...250 100...2501 1AF205-40-11-131SFL527102R13113.920250...500 250...5001 1AF205-40-11-141SFL527102R14113.92040030024...60 20...601 1AF265-40-11-111SFL547102R11116.38048...13048...1301 1AF265-40-11-121SFL547102R12116.380100...250 100...2501 1AF265-40-11-131SFL547102R13116.380250...500 250...5001 1AF265-40-11-141SFL547102R14116.38050035024...60 20...601 1AF305-40-11-111SFL587102R11116.38048...13048...1301 1AF305-40-11-121SFL587102R12116.380100...250 100...2501 1AF305-40-11-131SFL587102R13116.380250...500 250...5001 1AF305-40-11-141SFL587102R14116.38052542024...60 20...601 1AF370-40-11-111SFL607102R11116.38048...13048...1301 1AF370-40-11-121SFL607102R12116.380100...250 100...2501 1AF370-40-11-131SFL607102R13116.380250...500 250...5001 1AF370-40-11-141SFL607102R14116.380(1) For other auxiliary contacts arrangements, please contact your ABB local organization.Aø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION A-A 140 5.51"152.5 6.00"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"183.75 7.23"AF190, AF205AF265, AF305, AF370AF205-40-11AF370-40-111SFC101155V00011SFC101195V0001Main dimensions mm, inches03
3/144 ABB MOTOR PROTECTION AND CONTROL—AF116 ... AF370 4-pole contactors with 1 N.O. + 1 N.C. auxiliary contacts Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Auxiliary contact blocksMechanical interlock units(between two contactors)CAL19-11CAL19-11BAF116 ... AF3704 01 11 x CAL19-11+ 2 x CAL19-11B–AF116 ... AF3704 01 1–+ 2 x CAL19-11B (1)+ VM... (2)(1) Total number of auxiliary contact blocks for the two contactors. (2) Interlock type, according to the contactor ratings (see "Accessories").AF contactorwith bar connectionsCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockVM Mechanical interlockLT Terminal shroudAF contactorwith built-in cable clamps1SFC101205C020103
1SFC101201C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/145—AF116 ... AF140 4-pole contactors160 to 200 A AC-1AC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 350 V DC. These contactors are of the block type design with 4 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). • built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main polesFor connection with built-in cable clamps16016024...60 20...602 2AF116-40-22-11 1SFL427101R11222.29048...13048...1302 2AF116-40-22-121SFL427101R12222.290100...250 100...2502 2AF116-40-22-131SFL427101R13222.290250...500 250...5002 2AF116-40-22-141SFL427101R14222.29020017524...60 20...602 2AF140-40-22-111SFL447101R11222.29048...13048...1302 2AF140-40-22-121SFL447101R12222.290100...250 100...2502 2AF140-40-22-131SFL447101R13222.290250...500 250...5002 2AF140-40-22-141SFL447101R14222.290With bar connections16016024...60 20...602 2AF116-40-22B-111SFL427102R11222.19048...13048...1302 2AF116-40-22B-121SFL427102R12222.190100...250 100...2502 2AF116-40-22B-131SFL427102R13222.190250...500 250...5002 2AF116-40-22B-141SFL427102R14222.19020017524...60 20...602 2AF140-40-22B-111SFL447102R11222.19048...13048...1302 2AF140-40-22B-121SFL447102R12222.190100...250 100...2502 2AF140-40-22B-131SFL447102R13222.190250...500 250...5002 2AF140-40-22B-141SFL447102R14222.190(1) For other auxiliary contacts arrangements, please contact your ABB local organization.AF140-40-22AF140-40-22B1SFC101159V00011SFC101194V0001SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"10 0.39"120 4.72"128 5.04"SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"10 0.39"120 4.72"128 5.04"ASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"10 0.39"128 5.04"120 4.72"ASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"10 0.39"128 5.04"120 4.72"AF116, AF140-40-11AF116, AF140-40-11BMain dimensions mm, inches03
1SFC101202C0201 - Rev. B3/146 ABB MOTOR PROTECTION AND CONTROL—AF190 ... AF370 4-pole contactors275 to 525 A AC-1AC / DC operated with 2 N.O. + 2 N.C. auxiliary contactsAF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly induc-tive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 440 V DC. These contactors are of the block type design with 4 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). • built-in surge suppression • add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUc min. ... Uc max.Auxiliary contacts fittedTy pe(1)Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50/60 HzV DCkg4 N.O. main poles27523024...60 20...602 2AF190-40-22-111SFL487102R11223.94048...13048...1302 2AF190-40-22-121SFL487102R12223.940100...250 100...2502 2AF190-40-22-131SFL487102R13223.940250...500 250...5002 2AF190-40-22-141SFL487102R14223.94035025024...60 20...602 2AF205-40-22-111SFL527102R11223.94048...13048...1302 2AF205-40-22-121SFL527102R12223.940100...250 100...2502 2AF205-40-22-131SFL527102R13223.940250...500 250...5002 2AF205-40-22-141SFL527102R14223.94040030024...60 20...602 2AF265-40-22-111SFL547102R11226.40048...13048...1302 2AF265-40-22-12 1SFL547102R12226.400100...250 100...2502 2AF265-40-22-131SFL547102R13226.400250...500 250...5002 2AF265-40-22-141SFL547102R14226.40050035024...60 20...602 2AF305-40-22-111SFL587102R11226.40048...13048...1302 2AF305-40-22-121SFL587102R12226.400100...250 100...2502 2AF305-40-22-131SFL587102R13226.400250...500 250...5002 2AF305-40-22-141SFL587102R14226.40052542024...60 20...602 2AF370-40-22-111SFL607102R11226.40048...13048...1302 2AF370-40-22-121SFL607102R12226.400100...250 100...2502 2AF370-40-22-131SFL607102R13226.400250...500 250...5002 2AF370-40-22-141SFL607102R14226.400(1) For other auxiliary contacts arrangements, please contact your ABB local organization.Aø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION A-A 140 5.51"152.5 6.00"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"183.75 7.23"AF190, AF205AF265, AF305, AF370AF205-40-22AF370-40-221SFC101161V00011SFC101196V0001Main dimensions mm, inches03
—AF116 ... AF370 4-pole contactors with 2 N.O. + 2 N.C. auxiliary contacts Contactors and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactortypesMainpolesAvailableauxiliarycontactsSide-mounted accessories Auxiliary contact blocksMechanical interlock units(between two contactors)CAL19-11 (1)CAL19-11B (1)AF116 ... AF3704 02 22 x CAL19-11 included+ 2 x CAL19-11B–(1) The CEL19 auxiliary contact blocks can replace the CAL19-11 and CAL19-11B. Though, no auxiliary contact block can be mounted outside the CEL19.CAL19-11B2-pole auxiliarycontact blockCAL19-11B2-pole auxiliarycontact blockAF contactorwith built-in cable clamps ABB MOTOR PROTECTION AND CONTROL 3/1471SFC101207C0201 - Rev. B03
1SFC101217C02013/148ABB MOTOR PROTECTION AND CONTROL—EK550, EK1000 4-pole contactors 800 to 1000 A AC-1AC operated with 1 N.O. + 1 N.C. auxiliary contactsEK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 600 V DC, EK1000 up to 1000 V AC.These contactors are of the block type design with:•4 main poles•control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuit voltageUc(1)Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50 HzV 60 Hzkg80054048-1 1EK550-40-11SK827041-AD17.200110110...1201 1EK550-40-11SK827041-EF17.200110...115 115...1271 1EK550-40-11SK827041-EG17.200220220...2401 1EK550-40-11SK827041-EL17.200220...230230...2551 1EK550-40-11SK827041-EM17.200400...415-1 1EK550-40-11SK827041-AR17.2001000-48-1 1EK1000-40-11SK827044-AD17.500110110...1201 1EK1000-40-11SK827044-EF17.500110...115 115...1271 1EK1000-40-11SK827044-EG17.500220220...2401 1EK1000-40-11SK827044-EL17.500220...230230...2551 1EK1000-40-11SK827044-EM17.500400...415-1 1EK1000-40-11SK827044-AR17.500(1) Other control voltages see voltage code table.270 10.63"11 0.43"11 0.43"244 9.61"672.64"25 0.98"272 10.71"12.50.49"1)1)ø 11 0.43"1/L13/L25/L37/L42/T14/T26/T38/T42)40 139.5 5.49"6 0.24"225.5 8.88"23 0.91"223 8.78"(M10)4)5)3)1.57"1/L13/L25/L37/L42/T14/T26/T38/T4299 11.77"20 67 2.64"40 244 9.61"ø 270 10.63"11 0.43"1)11 0.43"2)11 0.43"1)1.57"0.79"8 0.31"139.5 5.49"225.5 8.88"23 0.91"4)(M10)5)223 8.78"40 3)1.57"EK550EK10001) Dimension for extra auxiliary contact block. 2) Screw, nut and washer by-packed. 3) Min. distance to uninsulated wall. 4) Damping elements are included. 5) Earthing screw.1SFC98099-069EK1000-40-11Main dimensions mm, inches03
1SFC101218C0201 ABB MOTOR PROTECTION AND CONTROL 3/149—EK550, EK1000 4-pole contactors 800 to 1000 A AC-1DC operated with 2 N.O. + 1 N.C. auxiliary contactsEK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 600 V DC, EK1000 up to 1000 V AC.These contactors are of the block type design with:• 4 main poles• control circuit: DC operated• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUcAuxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV DCkg800540242 1EK550-40-21SK827041-DB17.200482 1EK550-40-21SK827041-DD17.200752 1EK550-40-21SK827041-DG17.2001102 1EK550-40-21SK827041-DE17.2001252 1EK550-40-21SK827041-DU17.2002202 1EK550-40-21SK827041-DF17.2001000-242 1EK1000-40-21SK827044-DB17.500362 1EK1000-40-21SK827044-DC17.500482 1EK1000-40-21SK827044-DD17.500602 1EK1000-40-21SK827044-DT17.500752 1EK1000-40-21SK827044-DG17.5001102 1EK1000-40-21SK827044-DE17.5001252 1EK1000-40-21SK827044-DU17.5002202 1EK1000-40-21SK827044-DF17.500270 10.63"11 0.43"244 9.61"672.64"250.98"272 10.71"12.50.49"1)1/L13/L25/L37/L42/T14/T26/T38/T4E0263D8296 11.65"2)ø 11 0.43"40 139.5 5.49"6 0.24"225.5 8.88"23 0.91"223 8.78"(M10)4)5)3)1.57"1/L13/L25/L37/L42/T14/T26/T38/T4E1693D299 11.77"200.79"67 2.64"401.57"244 9.61"270 10.63"ø 11 0.43"2)296 11.65"11 0.43"1)8 0.31"139.5 5.49"225.5 8.88"23 0.91"4)(M10)5)223 8.78"40 3)1.57"EK550EK10001) Dimension for extra auxiliary contact block. 2) Screw, nut and washer by-packed. 3) Min. distance to uninsulated wall. 4) Damping elements are included. 5) Earthing screw.1SFC98099-069EK1000-40-2103
1SFC101219C02013/150ABB MOTOR PROTECTION AND CONTROL—EK550, EK1000 4-pole Contactors 800 to 1000 A AC-1AC operated with 2 N.O. + 2 N.C. auxiliary contactsEK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and for controlling power circuits up to 1000 V AC and 600 V DC, EK1000 up to 1000 V AC.These contactors are of the block type design with:•4 main poles•control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessoriesIECUL/CSARated control circuit voltageUc(1)Auxiliary contacts fittedType Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 40 °CAC-1General use rating600 V ACAAV 50 HzV 60 Hzkg80054048-2 2EK550-40-22SK827043-AD17.200110110...1202 2EK550-40-22SK827043-EF17.200110...115 115...1272 2EK550-40-22SK827043-EG17.200220220...2402 2EK550-40-22SK827043-EL17.200220...230230...2552 2EK550-40-22SK827043-EM17.200400...415-2 2EK550-40-22SK827043-AR17.2001000-48-2 2EK1000-40-22SK827045-AD17.500110110...1202 2EK1000-40-22SK827045-EF17.500110...115 115...1272 2EK1000-40-22SK827045-EG17.500220220...2402 2EK1000-40-22SK827045-EL17.500220...230230...2552 2EK1000-40-22SK827045-EM17.500380380...4152 2EK1000-40-22SK827045-EP17.500380...400400...4402 2EK1000-40-22SK827045-ER17.500400...415-2 2EK1000-40-22SK827045-AR17.500(1) Other control voltages see voltage code table.270 10.63"11 0.43"11 0.43"244 9.61"672.64"25 0.98"272 10.71"12.50.49"1)1)ø 11 0.43"1/L13/L25/L37/L42/T14/T26/T38/T42)40 139.5 5.49"6 0.24"225.5 8.88"23 0.91"223 8.78"(M10)4)5)3)1.57"1/L13/L25/L37/L42/T14/T26/T38/T4E1693D299 11.77"200.79"67 2.64"401.57"244 9.61"270 10.63"ø 11 0.43"2)296 11.65"11 0.43"1)E1694D8 0.31"139.5 5.49"225.5 8.88"23 0.91"4)(M10)5)223 8.78"40 3)1.57"EK550EK10001) Dimension for extra auxiliary contact block 2) Screw, nut and washer by-packed3) Min. distance to uninsulated wall 4) Damping elements are included 5) Earthing screw1SFC98099-069EK1000-40-22Main dimensions mm, inches03
1SFC101220C0201 ABB MOTOR PROTECTION AND CONTROL 3/151—EK550, EK1000 4-pole contactors with 1 N.O. + 1 N.C. and 2 N.O. + 1 N.C. auxiliary contactsMounting positions of the auxiliary contactAuxiliary contact types and connecting diagrams21221314CAL16-11 A CAL16-11 B43443132 CAL16-11 C61625354 CAL16-11 D83847172 CCL16-11 E47483536 (1)(1) Contact 35-36 used for some types of EK... contactorsEK 4-pole contactorsContactortypesMainpolesAvailableauxiliarycontactsAdd-on auxiliary contact blocks2-pole CAL16-11 ...Mounting and positioning Factory mounted auxiliary contacts Add-on CAL16-11 auxiliary contactsAC operated, 50 Hz, 60 Hz or 50/60 HzEK550, EK10004 0 1 1A+1 x CAL16-11BACDB+1 x CAL16-11C+1 x CAL16-11DDC operatedEK550, EK10004 0 2 1AE+1 x CAL16-11CACEEK 4-pole reversing contactors with VH800 mechanical and electrical interlock units"Left hand" contactors Interlocking"Right hand" contactorsAdd-on auxiliary contact blocks2-pole CAL16-11 ...Mounting and positioning Factory mounted auxiliary contacts Add-on CAL16-11 auxiliary contactsAC operated, 50 Hz, 60 Hz or 50/60 HzEK550, EK1000VH800EK550, EK1000+1 x CAL16-11CACDB1 x CAL16-11DDC operatedEK550, EK1000VH800EK550, EK1000–EEMain accessory fitting details - for ordering details, technical data and other accessories: see section accessories03
1SFC101220C02013/152ABB MOTOR PROTECTION AND CONTROL—EK550, EK1000 4-pole contactors with 1 N.O. + 1 N.C. auxiliary contacts and 2 N.O. + 1 N.C. auxiliary contacts A1A2A1A23153514264627788E0747DBSS550 ... BSS1000A078RC-EHFor contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgSide-mounted auxiliary contact blocksEK1 1CAL16-11BSK829002-B10.0501 1CAL16-11CSK829002-C10.0501 1CAL16-11DSK829002-D10.0501 1CCL16-11E (2)SK829002-E10.050Mechanical interlock unit for two horizontal mounted contactorsEK550, EK1000VH800SK829070-F16.000Connecting setsEK550BSS550SK829090-E13.300EK1000BSS1000SK829090-H15.500Surge suppressorsFor contactorsRated control circuit voltageUcTypeOrder codePkgqtyWeight(1 pce)VACDCkgEK550, EK100048...110–RC-EH800/110SK829007-C10.015EK550, EK100024...125–RC-EH800/110SK829007-C10.015EK550, EK1000220...600–RC-EH800/600SK829007-D10.015See "Main accessory fitting details" table.(2) Mounting of CCL16-11E blocks does not allow an additional second block to be added on top of it.All DC operated EK contactors are equipped with one CCL16-11E on the right side.03
1SBC101989S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/153—AF09 ... AF80 4-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF09AF16AF26AF38AF40AF52AF80StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C35 A35 A55 A55 A105 A105 A125 AWith conductor cross-sectional area6 mm²6 mm²16 mm²16 mm²35 mm²35 mm²50 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 25 A30 A45 A55 A70 A100 A125 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 25 A30 A40 A45 A60 A80 A105 Aθ ≤ 70 °C 22 A26 A32 A37 A50 A70 A90 AWith conductor cross-sectional area4 mm²6 mm²10 mm²16 mm²35 mm²35 mm²50 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 9 A18 A23.2 A23.2 A40 A53 A80 A380-400 V 9 A18 A22 A22 A40 A53 A80 A415 V 9 A18 A21.2 A21.2 A40 A53 A80 A440 V 9 A18 A20 A20 A40 A53 A80 A500 V 9.5 A15 A17.6 A17.6 A35 A45 A65 A690 V 7 A10.5 A10.5 A10.5 A25 A35 A49 ARated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V 2.2 kW4 kW5.5 kW5.5 kW11 kW15 kW22 kW380-400 V 4 kW7.5 kW11 kW (3)11 kW (3)18.5 kW22 kW37 kW415 V 4 kW9 kW11 kW11 kW22 kW30 kW45 kW440 V 4 kW9 kW11 kW11 kW22 kW30 kW45 kW500 V 5.5 kW9 kW11 kW11 kW22 kW30 kW45 kW690 V 5.5 kW9 kW9 kW9 kW22 kW30 kW45 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorsWithout thermal overload relay - Motor protection excludedUe ≤ 500 V AC - gG type fuse25 A32 A50 A63 A80 A110 A160 ARated short-time withstand current Icw1 s 300 A300 A450 A450 A1000 A1000 A1200 AAt 40 °C ambient temperature,in free air from a cold state10 s 150 A150 A300 A300 A600 A600 A780 A30 s 80 A80 A225 A225 A350 A350 A450 A1 min 60 A60 A150 A150 A250 A250 A300 A15 min 35 A35 A55 A55 A110 A110 A140 AMaximum breaking capacitycos φ = 0.45N.O. main poleat 440 V 250 A250 A--950 A950 A1100 Aat 690 V 106 A106 A--600 A600 A750 AN.C. Main poleat 440 V----600 A-900 Aat 690 V----300 A-750 APower dissipation per poleIe / AC-1 0.8 W1.2 W1.6 W2.3 W3 W6.3 W8 WIe / AC-3 0.1 W0.35 W0.42 W0.42 W1 W1.7 W3.2 WMax. electrical switching frequencyAC-1600 cycles/h(1) For the corresponding kW/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor Rated Operational Powers and Currents"(2) For the protection of motor starters against short circuits, see "Coordination with Short-circuit Protection Devices".(3) 400 V 3-phase motors only.03
1SFC101209C0201 - Rev. B3/154ABB MOTOR PROTECTION AND CONTROL—AF116 ... EK1000 4-pole contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370EK550EK1000StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 Rated operational voltage Ue max.690 V1000 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C160 A200 A 275 A350 A400 A500 A525 A800 A1000 AWith conductor cross-sectional area70 mm² 95 mm² 150 mm² 240 mm² (3) 240 mm² 300 mm² (4) 2x 185 mm² (4) 2x 240 mm² 2x 300 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 160 A200 A 275 A350 A400 A500 A525 A800 A1000 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 145 A175 A250 A300 A350 A400 A425 A650 A800 Aθ ≤ 70 °C 130 A160 A 200 A240 A290 A325 A350 A575 A720 AUe max. ≤ 1000 V, 50/60 Hzθ ≤ 40 °C--250 A275 A350 A375 A400 A800 A1000 Aθ ≤ 60 °C (2)--225 A250 A300 A325 A350 A650 A800 Aθ ≤ 70 °C--185 A200 A240 A260 A290 A575 A720 AWith conductor cross-sectional area70 mm² 95 mm² 150 mm² 240 mm² (3) 240 mm² 300 mm² (4) 2x 185 mm² (4) 2x 240 mm² 2x 300 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °C (2)Ie / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V116 A140 A 190 A205 A265 A305 A370 A550 A-380-400 V116 A140 A 190 A205 A265 A305 A370 A550 A-415 V116 A140 A 190 A205 A265 A305 A370 A550 A-440 V116 A140 A 190 A205 A265 A305 A370 A550 A-500 V-------550 A-690 V-------550 A-1000 V-------175 A-Rated operational power AC-3 (1)M31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors220-230-240 V30 kW37 kW 55 kW55 kW75 kW90 kW110 kW160 kW-380-400 V55 kW75 kW 90 kW110 kW132 kW160 kW200 kW280 kW-415 V55 kW75 kW 90 kW110 kW132 kW160 kW200 kW315 kW-440 V75 kW90 kW 110 kW132 kW160 kW160 kW200 kW315 kW-500 V-------400 kW-690 V-------500 kW-1000 V-------250 kW-Rated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorsWithout thermal overload relay - Motor protection excludedUe ≤ 500 V AC - gG type fuse200 A250 A 355 A400 A630 A630 A630 A800 A1000 ARated short-time withstand current Icw1 s 1300 A1460 A 1900 A2050 A2650 A3050 A3700 A5500 A6800 AAt 40 °C ambient temperature,in free air from a cold state10 s 928 A1168 A 1520 A1640 A2120 A2440 A2960 A5300 A6400 A30 s 536 A674 A878 A947 A1224 A1409 A1709 A3700 A4400 A1 min 379 A477 A 621 A670 A865 A996 A1208 A3000 A3400 A15 min 160 A200 A 275 A350 A400 A500 A525 A1000 A1200 AMaximum breaking capacityat 440 V 2000 A3000 A 3300 A3500 A3800 A4600 A5000 A5400 A-cos φ = 0.45at 690 V-------5400 A-Power dissipation per poleIe / AC-1 12 W18 W15 W25 W32 W50 W72 W60 W80 WIe / AC-3-------25 W-Max. electrical switching frequencyAC-1300 cycles/hAC-3300 cycles/h-AC-2, AC4-120 cycles/h-(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) θ ≤ 55 °C for EK550, EK1000(3) For currents above 275 A use terminal enlargements or terminal extensions.(4) For currents above 450 A use terminal enlargements or terminal extensions.03
1SBC100066S0201 ABB MOTOR PROTECTION AND CONTROL 3/155Main pole - Utilization characteristics according to UL/NEMA/CSAContactor typesAC / DC operatedAF09AF16AF26AF38AF40AF52AF80StandardsUL 508, CSA C22.2 N°14UL 60947-4-1, CSA-C22.2 No. 60947-4-1Max. operational voltage600 VUL / CSA general use rating600 V AC 25 A30 A45 A55 A60 A80 A105 AWith conductor cross-sectional areaAWG 10AWG 10AWG 8AWG 6AWG 6AWG 4AWG 21 pole80 V DC 25 A (1)30 A (1)45 A55 A60 A80 A105 A2 poles in serie160 V DC 25 A (1)30 A (1)45 A55 A60 A80 A105 A3 poles in serie240 V DC 25 A30 A45 A55 A60 A80 A105 A4 poles in serie320 V DC 25 A30 A45 A55 A60 A80 A105 AWith conductor cross-sectional areaAWG 10AWG 10AWG 8AWG 8AWG 6AWG 4AWG 2Max. electrical switching frequencyFor general use600 cycles/hNote: 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles, see "General technical data".(1) 20 A for AF09..-22-00 and AF16..-22-00.—AF09 ... AF80 4-pole contactorsTechnical dataMain pole utilization characteristics - 4 N.O. non-reversing contactorsContactor typesAC / DC operatedAF09AF16AF26AF38AF40AF52AF80Lighting application - UL / CSA - breaking all linesElectrical discharge lamps (ballast)1-phase per pole347 V AC 20 A30 A45 A50 A---3-phase break all lines600 V AC 20 A30 A45 A50 A---Elevator control, load switching, 500 000 electrical operating cyclesacc. to CSA B44.1 / ASME 17.5 paragraph 19.2.11-phaseHorse power rating110-120 V AC-1/2 hp-----220-240 V AC-1-1/2 hp-----3-phaseHorse power rating 200-208 V AC-3 hp-----220-240 V AC-3 hp-----440-480 V AC-7-1/2 hp-----550-600 V AC-10 hp-----Note: 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles, see "General technical data".03
1SBC100067S02013/156 ABB MOTOR PROTECTION AND CONTROL—AF116 ... EK1000 4-pole contactorsTechnical dataMain pole - Utilization characteristics according to UL/NEMA/CSAContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370EK550EK1000StandardsUL 60947-4-1UL 508, CSA C22.2 N°14Max. operational voltage600 VUL / CSA general use rating600 V AC160 A175 A230 A250 A300 A350 A420 A540 A-With conductor cross-sectional areaAWG 2/0AWG 3/0MCM 250 MCM 250 MCM 400 MCM 500 2//MCM 300--1 pole90 V DC 200 A200 A-------100 V DC--250 A350 A-----110 V DC----400 A500 A520 A--2 poles in serie175 V DC 200 A200 A-------200 V DC--250 A350 A-----225 V DC----400 A500 A520 A--3 poles in serie260 V DC 200 A200 A-------300 V DC--250 A350 A-----340 V DC----400 A500 A520 A--4 poles in series350 V DC 200 A200 A-------400 V DC--250 A350 A-----450 V DC----400 A500 A520 A--With conductor cross-sectional areaAWG 2/0AWG 3/0MCM 250 MCM 250 MCM 400 MCM 500 2//MCM 300--Max. electrical switching frequencyFor general use300 cycles/hMain pole utilization characteristics - 4 N.O. non-reversing contactorsContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370EK550EK1000Lighting application - UL/CSA - breaking all linesElectrical discharge lamps (ballast)1-phase per pole347 V AC 160 A200 A250 A300 A400 A450 A520 A--3-phase break all lines600 V AC 160 A200 A250 A300 A400 A450 A520 A--03
1SBC101990S0201 - Rev. A1SBC101990S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/157—AF09 ... AF80 4-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF09AF16AF26AF38AF40AF52AF80Rated insulation voltage Uiacc. to IEC 60947-4-1690 V1000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kV8 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactorOperation-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionB2AAB1C2C14 N.O.Main polesA30 g20 gB1 25 g Closed position / 5 g Open position20 g Closed position / 5 g Open positionB2 15 g10 gC1 25 g20 gC2 25 g20 g2 N.O. + 2 N.C.Main polesA30 g30 g Closed position / 25 g Open position20 gB1 25 g Closed position / 5 g Open position25 g Closed position / 5 g Open position20 g Closed position / 5 g Open position20 g Closed position / 4 g Open positionB2 15 g 15 g Closed position / 10 g Open position10 gC1 25 g 25 g Closed position / 20 g Open position20 gC2 25 g25 g Closed position / 20 g Open position20 gVibration withstandacc. to IEC 60068-2-65 ... 300 Hz4 g Closed position / 2 g Open position5 ... 300 Hz3 g Closed position / 2 g Open position(1) Environment B: all AF09 ... AF38 contactors produced since week 08-2013. AF09 ... AF38-..-..-12 (48...130 V 50/60 Hz-DC) compliant to environment A only: for environment B select AF09Z ... AF38Z-..-..-22.Mounting characteristics and conditions for useContactor typesAF09AF16AF26AF38AF40AF52AF80Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.C. auxiliary contacts: see accessory fitting details for a 4-pole contactor AF09 ... AF80Mounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mm35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally2 x M4 or 2 x M6 screws placed diagonallyThese contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising 2 separate loads with a single supply (see diagrams beside). When the contactor operates there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE.12R5R6R3R478A1A212R5R6R3R478LoadLoadBack-upsupply Main supply A1A212R5R6R3R478LoadLoadSupply These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.Block diagramsRemark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles - Single supply and 2 separate loads - 2 separate supplies and 2 separate loads03
1SFC101212C02013/158ABB MOTOR PROTECTION AND CONTROL—AF116 ... EK1000 4-pole contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.8 kVElectromagnetic compatibilityAF contactors comply with IEC 60947-1 / EN 60947-1 - Environment AAmbient air temperature close to contactorOperation-40 to +70 °CStorage-40 to +70 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles5 million operating cyclesMaximum switching frequency300 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1No change in contact position, closed or open positionB2AAB1C2C1ABBShock direction1/2 sinusoidal shock for 11 ms1/2 sinusoidal shock for 30 msA20 g20 gB1 15 g closed position / 3 g open position15 g closed position / 3 g open positionB2 15 g closed position / 3 g open position15 g closed position / 3 g open positionC1 20 g20 gC2 20 g20 gVibration withstandacc to IEC 60068-2-60.7 g closed position / 0.7 g open position 13.2...100 HzGeneral technical dataContactor typesAC or DC operatedEK550EK1000Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL600 VRated impulse withstand voltage Uimp.8 kVElectromagnetic compatibilityEK contactors complying with IEC 60947-1 / EN 60947-1 - Environment AAmbient air temperature close to contactorOperationFitted with thermal overload relay-25 to +55 °C-Without thermal overload relay-40 to +70 °C-Storage-50 to +70 °C-Climatic withstandCategory B acc. to IEC 60068-2-30Maximum operating altitude (without derating)≤ 3000 mMechanical durabilityNumber of operating cycles5 millions operating cycles3 millions operating cyclesMax. switching frequency60 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Closed or open positionB2AAB1C2C1E1862DABBShock direction1/2 sinusoidal shock for 15 ms: no change in contact position, closed or open positionA10 gB1 10 gB2 10 gC1 10 gC2 10 g03
1SBC101991S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/159—AF09 ... AF80 4-pole contactorsTechnical dataMagnet system characteristics AF09 ... AF80 AC / DC operatedContactor typesAC / DC operatedAF09AF16AF26AF38AF40AF52AF80Coil operating limitsacc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.at θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxDC supplyat θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max at θ ≤ 70 °C 0.85 x Uc min ... Uc max at θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24...500 V ACCoil consumptionAverage pull-in value50 VA 40 VAAverage holding value2.2 VA / 2 W 4 VA / 2 WDC control voltageRated control circuit voltage Uc20...500 V DC20...500 V DCCoil consumptionAverage pull-in value50 W 40 WAverage holding value2 W 2 WPLC-output controlAF...-11 not suitable for direct control by PLC-output.-Drop-out voltage≤ 60 % of Uc min.≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706–conditions of use on requestDips withstand -20 °C ≤ θ ≤ +60 °C–24 ms averageOperating timeBetween coil energization and:N.O. contact closing 40...95 ms48...120 msN.C. contact opening 38...90 ms44...115 msBetween coil de-energization and:N.O. contact opening 11...95 ms16...110 msN.C. contact closing 13...98 ms18...113 msMagnet System Characteristics AF09Z...AF38Z 24V DC operated designed for PLC - coil 30Contactor typesDC operatedAF09ZAF16ZCoil operating limitsacc. to IEC 60947-4-1DC supplyat θ ≤ 60 °C 0.85 ... 1.1x Ucat θ ≤ 70 °C UcDC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull-in value6 WAverage holding value1.7 WPLC-output control ≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detection Drop-out voltage≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706-Dips withstand -20 °C ≤ θ ≤ +60 °C-Operating time27 ... 53 msBetween coil energization and:N.O. contact closingN.C. contact opening 20 ... 35 msBetween coil de-energization and:N.O. contact opening 17 ... 29 msN.C. contact closing 22 ... 57 msMagnet System Characteristics AF09Z...AF38Z AC / DC operated for specific applications - coils 20, 21, 22, 23Contactor typesAC / DC operatedAF09ZAF16ZAF26ZAF38ZCoil operating limitsacc. to IEC 60947-4-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max. At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyat θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24...250 V ACCoil consumptionAverage pull-in value16 VAAverage holding value1.7 VA / 1.5 WDC control voltageRated control circuit voltage Uc12...250 V DCCoil consumptionAverage pull-in value12 ... 16 WAverage holding value1.7 WPLC-output control(AF..Z coil 21) ≥ 500 mA 24 V DC for PLCs - Not suitable for safety PLCsDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706(AF..Z coil 21, 22, 23) conditions of use on request Dips withstand -20 °C ≤ θ ≤ +60 °C(AF..Z coil 21, 22, 23) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DCOperating time40...95 msBetween coil energization and:N.O. contact closingN.C. contact opening 38...90 msBetween coil de-energization and:N.O. contact opening 11...95 msN.C. contact closing 13...98 ms03
1SFC101210C0201 - Rev. A3/160ABB MOTOR PROTECTION AND CONTROL—AF116 ... AF370 4-pole contactorsTechnical dataMagnet system characteristicsContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370Coil operating limitsAC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxacc. to IEC 60947-4-1DC supplyAt θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc maxRated control circuit voltage Uc24...500 V AC, 20...500 V DCCoil consumptionAC control voltage 50/60 Hz24...60 V ACAverage pull-in value225 VA165 VA475 VAAverage holding value5.5 VA6 VA8.5 VA48...130 V ACAverage pull-in value170 VA175 VA340 VAAverage holding value4 VA4 VA17 VA100...250 V ACAverage pull-in value130 VA220 VA385 VAAverage holding value6 VA7 VA17.5 VA250...500 V ACAverage pull-in value205 VA185 VA420 VAAverage holding value16 VA16 VA21 VADC control voltage20...60 V DCAverage pull-in value210 W205 W400 WAverage holding value2.5 W2.5 W3.5 W48...130 V DCAverage pull-in value130 W130 W360 WAverage holding value2.5 W2.5 W2.5 W100...250 V DCAverage pull-in value135 W190 W410 WAverage holding value3 W2.5 W4.5 W250...500 V DCAverage pull-in value205 W190 W600 WAverage holding value4 W4 W4.7 WDrop-out voltage55 % of Uc minVoltage sag immunityConditions of use on requestacc. to SEMI F47Dips withstand≥ 20 msOperating time Coil supply between A1 - A2Between coil energization and:N.O. contact closing 20...55 ms25...60 ms30...60 msBetween coil de-energization and:N.O. contact opening 40..70 ms45...80 ms45...80 msMounting characteristics and conditions for useContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 4-pole contactor AF116 ... AF370Mounting distancesThe contactors can be assembled side by sideFixingOn rail acc. to IEC 60715, EN 60715-By screws 4 x M44 x M503
1SFC101211C0201 ABB MOTOR PROTECTION AND CONTROL 3/161—EK550 ... EK1000 4-pole contactorsTechnical dataMagnet system characteristicsContactor typesAC operatedEK550EK1000Coil operating limitsAC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.acc. to IEC 60947-4-1Please also refer to "Mounting characteristics and conditions for use"AC control voltageRated control circuit voltage50 Hz 48...500 V60 Hz 110...600 VCoil consumptionAverage pull-in value50 Hz 3500 VA60 Hz 4000 VA50/60 Hz (1)3800 / 3400 VAAverage holding value50 Hz 125 VA / 50 W60 Hz 140 VA / 60 W50/60 Hz (1)140 VA /60 WDrop-out voltage in % of Uc min.approx. 45...65 %Operating timeBetween coil energization and:N.O. contact closing 30...60 msN.C. contact opening 25...55 msBetween coil de-energization and:N.O. contact opening 10...20 msN.C. contact closing 13...23 ms(1) "A" coil voltage: see "Coil voltage code table".Magnet system characteristicsContactor typesDC operatedEK550EK1000Coil operating limitsDC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.acc. to IEC 60947-4-1Please also refer to "Mounting characteristics and conditions for use"DC control voltageRated control circuit voltage24...220 VCoil consumptionAverage pull-in value1100 WAverage holding value20 WDrop-out voltageapprox. 15...50 % of Uc min.Coil time constantOpenL/R12 msClosedL/R60 msOperating timeBetween coil energization and:N.O. contact closing 60...80 msN.C. contact opening 55...75 msBetween coil de-energization and:N.O. contact opening 10...35 msN.C. contact closing 13...38 msMounting characteristics and conditions for useContactor typesAC / DC operatedEK550EK1000Mounting positionsABBABBABBABBE1863D1Position 1Position 3Position 4Position 2Position 5Position 1 30+30-30Position 6Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 4-pole contactor EK550, EK1000Control voltage / Ambient temperatureMounting positions1, 1±30°, 2, 3, 4, 5at θ ≤ 70 °C 0.85...1.1 x Uc6at θ ≤ 70 °CUnauthorizedMounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 60715–By screws4 x M6 (2)(2) Damping elements are supplied.03
1SBC101988S0201 - Rev. A3/162ABB MOTOR PROTECTION AND CONTROL—AF09 ... AF80 4-pole contactorsTechnical dataConnecting characteristicsContactor typesAF09AF16AF26AF38AF40AF52AF80Main terminalsScrew terminals with cable clampScrew terminals with double connector 2 x (5.5 width x 6.8 depth)Screw terminals with double connector 2 x (9.3 width x 7.9/10.3 depth)Screw terminals with double connector 2 x (12.4 width x 9.3/11.1 depth)Connection capacity (min. ... max.)Main conductors (poles)RigidSolid (≤ 4 mm²)1 x 1...6 mm²1.5...16 mm²6...35 mm²6...70 mm²Stranded (≥ 6 mm²)2 x 1...6 mm²1.5...16 mm²6...35 mm²6...50 mm²Flexible with non insulated ferrule1 x 0.75...6 mm²1.5...16 mm²4...35 mm²6...50 mm²2 x 0.75...6 mm²1.5...16 mm²4...35 mm²6...50 mm²Flexible with insulated ferrule1 x 0.75...4 mm²1.5...16 mm²4...35 mm²6...50 mm²2 x 0.75...2.5 mm²1.5...16 mm²4...35 mm²6...50 mm²L6Bars or lugsL <9.6 mm-9.2 mm12.2 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 16...10AWG 16...6AWG 10...2AWG 6...1Stripping length10 mm12 mm16 mm17 mmTightening torque1.5 Nm / 13 lb.in2.5 Nm / 22 lb.in4 Nm / 35 lb.in6 Nm / 53 lb.inAuxiliary conductors(coil terminals)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torque1.2 Nm / 11 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20IP10Coil terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM3.5M4.5M6M8Screwdriver typeFlat Ø 5.5 / Pozidriv 2Flat Ø 6.5 / Pozidriv 2hexagon socket (s = 4 mm)Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
Connecting characteristicsContactor typesAC / DC operatedAF116AF140AF190AF205AF265AF305AF370Main terminalsFlat typeø 6.51373ø 8.517.5105ø 10.519.514.35Connection capacity (min. ... max.)Main conductors (poles) Cu cable - Stranded1 x 10...95 mm²6...150 mm²16...300 mm²Clamp typeLD... included (1)1SDA066917R11SDA055016R1Tightening torque8 Nm14 Nm25 NmCu cable - Stranded 2 x 10...95 mm²50...120 mm²70...185 mm²Clamp typeLD... included (1)1SFN074709R1000, LZ185-2C/1201SCA022194R0890, OZXB4Tightening torque8 Nm16 Nm22 NmAl cable - Stranded1 x–95...185 mm²185...240 mm²Clamp type–1SDA054988R11SDA055020R1Tightening torque–31 Nm43 NmCu cable - Flexible1 x 10...70 mm²6...120 mm²16...240 mm²Clamp typeLD... included (1)1SDA066917R11SDA055016R1Tightening torque8 Nm14 Nm25 Nm Cu cable - Flexible2 x 10...70 mm²50...95 mm²70...185 mm²Clamp typeLD... included (1)1SFN074709R1000, LZ185-2C/1201SCA022194R0890, OZXB4Tightening torque8 Nm16 Nm22 NmLøLugsL ≤ 22 mm (.866 in)24 mm (.945 in)32 mm (1.260 in)Ø >6 mm (.236 in)8 mm (.315 in)10 mm (.394 in)Socket typeLL... includedLL... includedLL... includedTightening torque9 Nm / 80 lb.in18 Nm / 160 lb.in28 Nm / 248 lb.inConnection capacity acc. to UL / CSA1 x AWG 6...3/06...300 MCM4...400 MCMClamp typeLD... included (1)ATK185 (2)ATK300 (2)Tightening torque8 Nm / 71 lb.in34 Nm / 301 lb.in42 Nm / 372 lb.inConnection capacity acc. to UL / CSA2 x AWG 6...3/0– 4...500 MCMClamp typeLD... included (1)–ATK300/2 (2)Tightening torque8 Nm / 71 lb.in–42 Nm / 372 lb.inAuxiliary conductors(coil terminals)Solid / stranded1 x 1...4 mm²2 x 1...4 mm²Flexible1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL <8 mml >3.5 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length9 mmTightening torque1.00 Nm / 9 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM6M8M10Screwdriver typeScrews and boltsCoil terminals (delivered in open position)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 2(1) LD... not included for AF116 ... AF146-30-..B. (2) Available in North America only.—AF116 ... AF370 4-pole contactors Technical data1SFC101213C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/16303
1SFC101214C02013/164ABB MOTOR PROTECTION AND CONTROL—EK550 ... EK1000 4-pole contactorsTechnical dataConnecting characteristicsContactor typesAC or DC operatedEK550EK1000Main terminalsFlat typeE1864D15ø 6.64.5E1868D40ø 118Connection capacity (min. ... max.)Main conductors (poles)Rigid with connectorCu cable1 x 70...300 mm²-Al/Cu cable1 x 70...300 mm²95...300 mm²Al/Cu cable2 x 35...185 mm²95...300 mm²LøBars or lugsL ≤ 55 mmØ >10 mmConnection capacity acc. to UL/CSA1 or 2 x 3 x 4 - 500 MCM-Tightening torqueRecommended18 Nm / 160 Ib.inMax.22 NmAuxiliary conductors(coil terminals)Rigid solid1 x 0.5...2.5 mm²2 x 0.5...2.5 mm²Flexible with ferrule1 x 0.5...2.5 mm²2 x 0.5...2.5 mm²LlBars or lugsL ≤ 8 mml >3.7 mmConnection capacity acc. to UL/CSA1 or 2 x 18...14 AWGTightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM10Screws and boltsCoil terminals (delivered in open positions)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 203
—4-pole contactorsElectrical durability and utilization categoriesGeneralUtilization categories determine the current making and breaking conditions relating to the characteristics of the loads to be controlled by the contactors. International standard IEC 60947-4-1 and European standard EN 60947-4-1 are the standards to be referred to.If Ic is the current to be broken by the contactor and Ie the rated operational current normally drawn by the load, then:• Categories AC-1: Ic = IeGenerally speaking Ic = m x Ie where m is a multiple of the load operational current.On next pages, the curves corresponding to categorie AC-1 represent the electrical durability variation of standard contactors in relation to the breaking current Ic.Electrical durability curves:• categories AC-1: the curves represent the electrical durability variation of standard contactors in relation to the breaking current Ic.Electrical durability is expressed in millions of operating cycles.Curve utilization modeElectrical durability forecast and contactor selection for categories AC-1• Note the characteristics of the load to be controlled: -Operational voltage ...............Ue - Current normally drawn ........Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents"). - Utilization category ...............AC-1 - Breaking current .....................Ic = Ie for AC-1• Define the number of operating cycles N required.• On the diagram corresponding to the operational category, select the contactor with the curve immediately above the intersection point (Ic ; N).Case of uninterrupted dutyFor uninterrupted duty, some verifications of preventing maintenance are necessary to check the functionality of the concerned product (consult us). The combined effect of environmental conditions and the proper temperature of the product may require some disposals. As a matter of fact, for this duty, the use duration prevails over the number of operating cycles. ABB MOTOR PROTECTION AND CONTROL 3/1651SBC100064S0201 - Rev. A03
—4-pole contactorsElectrical durabilityElectrical durability for AC-1 utilization category - Ue ≤ 690 V Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load.Ambient temperature and maximum electrical switching frequency: see "Technical data".135791357913579135791357913579135791010.10.20.30.5351010010002352030502003005002AF09AF16AF26AF40AF52AF38AF80Millions of operatingcyclesBreaking current Ic (A)3/166ABB MOTOR PROTECTION AND CONTROL1SBC100322S020103
—Notes ABB MOTOR PROTECTION AND CONTROL 3/16703
—Contactors for DC switching— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R13103/170 Overview 3/172 Contactors for DC switching applications3/173 Connection diagrams Selection table for DC switching3/174 AF09 ... AF96 contactors3/175 AF116 ... AF2650 contactors3/176 EK550 ... EK1000 contactors Ordering details 100 A DC-13/178 GA75 AC operated3/179 GAE75 DC operated 250 to 400 A DC-13/180 GAF185 ... GAF300 AC / DC operated with 1 N.O. + 1 N.C. 600 to 875 A DC-13/181 GAF460 ... GAF750 AC / DC operated with 1 N.O. + 1 N.C. 1040 to 1750 A DC-13/182 GAF1250 ... GAF2050 AC / DC operated with 1 N.O. + 1 N.C.3/183 Technical data3/404 Voltage code table ABB MOTOR PROTECTION AND CONTROL 3/16903
3/170 ABB MOTOR PROTECTION AND CONTROL—GAF contactorsThe compact efficient way to switch DC loadsDCProven technologyThe GAF range of contactor is based on the tested and well proven AFcontactor range. The GAF share all accessories with the AF range, reduc-ing the number of parts needed.Easy selection The GAF contactors feature ABBs AF technology and all of its features. With only four coils the entire voltage range of 20 V DC and 24 V AC to 500 V AC / DC is covered. The built in surge suppression takes away the need of a separate surge suppressor. All to enable easier selection of contactors.Up to 2050 A1000 V DC-1The GAF range of DC contactors extends from 250 A up to 2050 A for DC-1 and UL DC general use at 1000 V.PV plant applications for DC switchingContactors are typically selected for applications that need remote control and switching of the central inverter’s DC side at least once per day. Application examples include: disconnection of the inverter from PV strings; or changing the string configuration to increase plant capacity.03
1SBC100507S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/171—GAF contactorsThe compact efficient way to switch DC loadsOptimised for central invertersABB offers the widest range of compact contactors for DC load switching in low voltage power distribution applications. Due to their breaking performance for DC circuits, GAF contactors can switch DC loads of up to 2050 A 1000 V DC-1.— PV solar plantBlock contactortype AFBlock contactortype GAFPV stringsSolar PVcentral inverterACGrid sideDC03
1SBC101980S02013/172 ABB MOTOR PROTECTION AND CONTROL—Contactors for DC switching applicationsDC-1, DC-3, DC-5 applications according to IEC 60947-4-1The circuit switching on DC is more difficult than on AC, as alternating current go to zero according to the frequency of the supply source while DC current has a continuous value. The main parameters to be considered for selecting a contactor are the current, the voltage and the L/R time constant of the controlled load.Time constant and utilization categoriesIn DC applications, the nature of load to switch (resistor, inductance or a combination) is characterized by the ratio of the in-ductance to the resistance (L (inductance of operated circuit) / R (resistance of operated circuit) = mH/Ω = ms)This ratio L/R is called the time constant of the circuit.DC current utilization categories are defined according to IEC 60947-4-1:• DC-1 non inductive or slightly inductive loads, resistance furnaces (L/R ≤ 1 ms)• DC-3 shunt motors: starting, plugging, inching, dynamic breaking of DC motors (L/R ≤ 2 ms)• DC-5 series motors: starting, plugging, inching, dynamic breaking of DC motors (L/R ≤ 7.5 ms).The higher the time constant value is, the more difficult it is to break the arc.The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs, by reducing the time con-stant.Operational voltage• The higher the operational voltage value is, the more difficult it is to break the arc.• The use of main poles connected in series will allow to increase the value of switched voltage.However, the maximum switched voltage must be within the max operational voltage of the contactor. All the poles required for breaking must be connected in series between the load and the source polarity not linked to earth (or chassis) (see recommended connection diagrams).ABB offer a large choice of possibilities for DC switching applications (see selection tables):• Standard 3-pole or 4-pole contactors with either 1- pole breaking or breaking with poles connected in series. • Special contactors designed for DC breaking with permanent magnets fitted on the main poles for use with the 3 poles connected in series and considered as 1-pole devices: - GA75 and GAE75 contactors: the 3 poles are connected in series via two supplied and fitted insulated connections (25 mm²) - GAF145 ... GAF2050 contactors: the 3 poles must be connected in series by the user according to conductor cross-sec-tional area (refer to main pole technical data) or by using LP connection bars to be ordered separately.Selection tablesThe enclosed selection tables will guide your choice through all contactor variants according to utilization category, for op-erational voltage up to 1000 V DC-1 and operational current up to 2050 A in ambient temperatures from -25 °C up to 40 °C.For higher values of current or voltage or heavy DC switching applications see bar mounted R contactors. 03
1SBC101980S0201 ABB MOTOR PROTECTION AND CONTROL 3/173—Connection diagramsConnection diagramsRecommended connectionIn the example below, the 3 poles are connected in series without the load in between. This connection is recommended in systems according to the following configurations.+-LoadIndirect earthed system (isolated system)+-LoadIndirect earthed system (isolated system)Direct earthed systemCentre earthed systemAlternative connection (not possible for GA75, GAE75)The load could be placed in between the contacts in a indirect earthed system. If not connected according to the configura-tion below, a fault to earth could result in one or two contacts breaking the full load which the contactor is not approved for.Points to considerThe above relates to power circuit switching. The SCPD (Short Circuit Protection Device) must comply with applicable protection rules.Polarity:For all GA, GAE, GAF types, connection polarities must be respected.(See instruction leaflet and see markings on the main terminals or the contactor front)03
1SBC101911S02013/174ABB MOTOR PROTECTION AND CONTROL—AF09 ... AF96 contactors DC circuit switchingGeneralThe arc switching on DC is more difficult than on AC.•For selecting a contactor it is essential to determine the current, the voltage and the L/R time constant of the controlled load•For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces (L/R ≈ 1 ms), inductive loads such as shunt motors (L/R ≈ 2 ms) or series motors (L/R ≈ 7.5 ms)•The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs•All the poles required for breaking must be connected in series between the load and the source polarity not linked to earth(or chassis).Technical data•The tables indicate for the standard contactors the Ie max. operating currents depending on: the utilization category (i.e. L/R)DC-1, DC-3, DC-5 as defined in the IEC 60947-4-1 publication, the operating voltage Ue and the pole coupling details. Ampere values quoted in these tables are valid for a -25...+70 °C temperature close to the contactors, as long as these valuesdo not exceed the AC-1 Ampere values for the corresponding ambient temperature•Max. switching frequency: 300 cycles/h.Selection tableContactor typesAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF963 or 4-pole3-pole4-pole3-pole3-pole4-pole3-pole3-pole3-pole3-pole3-poleUtilization category DC-1, L/R ≤ 1 ms≤ 72 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A110 V 10 A15 A20 A----------220 V-------------≤ 72 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A110 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A220 V 10 A15 A20 A----------≤ 72 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A110 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A220 V 25 A27 A30 A45 A45 A50 A50 A55 A70 A100 A105 A125 A130 A≤ 72 V 25 A-30 A-45 A--55 A-----110 V 25 A-30 A-45 A--55 A-----220 V 25 A-30 A-45 A--55 A-----440 V 10 A-20 A----------Utilization category DC-3, L/R ≤ 2 ms≤ 72 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A110 V 6 A7 A8 A----------220 V-------------≤ 72 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A110 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A220 V 6 A7 A8 A----------≤ 72 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A110 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A220 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A≤ 72 V 25 A-30 A----------110 V 25 A-30 A----------220 V 25 A-30 A----------440 V 6 A-8 A----------Utilization category DC-5, L/R ≤ 7.5 ms≤ 72 V 9 A12 A16 A20 A-25 A25 A-70 A100 A105 A125 A130 A110 V 4 A4 A4 A----------220 V-------------≤ 72 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A110 V 10 A15 A20 A45 A-50 A50 A-70 A100 A105 A125 A130 A220 V 4 A4 A4 A----------≤ 72 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A110 V 25 A27 A30 A45 A-50 A50 A-70 A100 A105 A125 A130 A220 V 9 A12 A16 A20 A-25 A25 A-70 A100 A105 A125 A130 A≤ 72 V 25 A-30 A----------110 V 25 A-30 A----------220 V 10 A-20 A----------440 V 4 A-4 A----------For additional ratings ≥ 440 V, please consult us.Note: For AFS09 ... AFS96 safety contactors, DC switching rating are the same as AF09 ... AF96 3-pole contactors.03
1SBC101944S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/175—AF116 ... AF2650 contactors DC circuit switchingSelection tableContactor typesAF116AF140 AF146AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1250AF1350AF1650AF2050AF26503 or 4-pole3-pole3 or 4-pole3-poleUtilization category DC-1, L/R ≤ 1 ms≤ 72 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A90 V160200200250350400500520---------100 V---250350400500520---------110 V-----400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A≤ 72 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A110 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A175 V160200200250350400500520600 A 700 A 800 A 1050 A-----200 V---250350400500520600 A 700 A 800 A 1050 A-----220 V-----400500520600 A 700 A 800 A 1050 A-----(1)≤ 72 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A110 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A220 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A260 V160200200250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A300 V---250350400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A340 V-----400500520600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A440 V--------600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A600 V--------600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A780 V--------600 A 700 A 800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A850 V----------800 A 1050 A 1250 A 1350 A 1650 A 2050 A 2650 A< 350 V200200-250350400500520---------400 V---250350400500520---------440 V-----400500520---------(1) AF2650 at 780 V DC = 2650 AUtilization category DC-3, L/R ≤ 2 ms≤ 72 V-------600 A 700 A 800 A 1050 A-----110 V-------600 A 700 A 800 A 1050 A-----≤ 72 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----110 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----220 V-------600 A 700 A 800 A 1050 A-----≤ 72 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----110 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----220 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----440 V-------600 A 700 A 800 A 1050 A-----600 V-------600 A 700 A 800 A 1050 A-----320 V 145 A 160 A-250 A 275 A 350 A 400 A 450 A---------Utilization category DC-5, L/R ≤ 7.5 ms≤ 72 V-------600 A 700 A 800 A 1050 A-----110 V-------600 A 700 A 800 A 1050 A-----≤ 72 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----110 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----220 V-------600 A 700 A 800 A 1050 A-----≤ 72 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----110 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----220 V 145 A 160 A250 A 275 A 350 A 400 A 450 A 600 A 700 A 800 A 1050 A-----440 V-------600 A 700 A 800 A 1050 A-----600 V-------600 A 700 A 800 A 1050 A-----320 V 145 A 160 A-250 A 275 A 350 A 400 A 450 A---------For additional ratings ≥ 440 V, please consult us.03
1SBC101986S02013/176ABB MOTOR PROTECTION AND CONTROL—EK550, EK1000 contactorsDC circuit switchingSelection tableContactor typesEK550EK1000Utilization category DC-1, L/R ≤ 1 msA 829D≤ 72 VA550–110 VA550–A 830D≤ 72 VA800–110 VA800–220 VA800–A 831D≤ 72 VA800–110 VA800–220 VA800–440 VA650–600 VA650–A 832D≤ 72 VA800–110 VA800–220 VA800–440 VA650–600 VA650–Utilization category DC-3, L/R ≤ 2 msA 829D≤ 72 VA550–A 830D≤ 72 VA650–110 VA650–220 VA650–A 831D≤ 72 VA650–110 VA650–220 VA650–440 VA650–600 VA650–A 832D≤ 72 VA650–110 VA650–220 VA650–440 VA650–600 VA650–Utilization category DC-5, L/R ≤ 7.5 msA 830D≤ 72 VA650–110 VA650–220 VA650–A 831D≤ 72 VA650–110 VA650–220 VA650–440 VA650–600 VA650–A 832D≤ 72 VA650–110 VA650–220 VA650–440 VA650–600 VA650–03
ABB MOTOR PROTECTION AND CONTROL 3/17703—Notes
1SBC101423S02013/178ABB MOTOR PROTECTION AND CONTROL1SBC586544F0301GA75-10-11—GA75 1-pole contactors100 A DC-1AC operatedGA75 contactors are designed for controlling shunt or series motors and resistive or slightly inductive loads up to 1000 V DC.These contactors are of the block type design with 3 main poles connected in series.•main poles arc chutes fitted with permanent magnets specially designed for DC breaking.The connection polarities must be respected. •control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operationalcurrentθ ≤ 55 °C 440 V DC-1General use rating 440 V DCAAV 50 HzV 60 Hzkg10010024240 0GA75-10-001SBL411025R81001.2201 1GA75-10-111SBL411025R81111.26048480 0GA75-10-001SBL411025R83001.2201 1GA75-10-111SBL411025R83111.260110110...1200 0GA75-10-001SBL411025R84001.2201 1GA75-10-111SBL411025R84111.260220...230 230...2400 0GA75-10-001SBL411025R80001.2201 1GA75-10-111SBL411025R80111.260230...240 240...2600 0GA75-10-001SBL411025R88001.2201 1GA75-10-111SBL411025R88111.260380...400400...4150 0GA75-10-001SBL411025R85001.2201 1GA75-10-111SBL411025R85111.260400...415 415...4400 0GA75-10-001SBL411025R86001.2201 1GA75-10-111SBL411025R86111.260(1) Other control voltages see voltage codes table.12 0.47"110 4.33"70 2.76"110.43"11 0.43"100.39"6.50.26"60.24"10 0.39"40.16"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"72 2.83"72 2.83"GA75-10-11Main dimensions mm, inches03
1SBC101424S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/1791SBC586554F0301GAE75-10-11—GAE75 1-pole contactors100 A DC-1DC operatedGAE75 contactors are designed for controlling shunt or series motors and resistive or slightly inductive loads up to 1000 V DC.These contactors are of the block type design with 3 main poles connected in series.• main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection polarities must be respected. • control circuit: DC operated with double winding coil (and factory mounted lagging contact for "holding" winding insertion)• add-on auxiliary contact blocks for side mounting and a wide range of accessoriesIECUL/CSARated control circuit voltageUc(1)Auxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 55 °C 440 V DC-1General use rating 440 V DCAAV DCkg100100120 0GAE75-10-001SBL419025R80001.2601 1GAE75-10-111SBL419025R80111.300240 0GAE75-10-001SBL419025R81001.2601 1GAE75-10-111SBL419025R81111.300480 0GAE75-10-001SBL419025R83001.2601 1GAE75-10-111SBL419025R83111.3001100 0GAE75-10-001SBL419025R86001.2601 1GAE75-10-111SBL419025R86111.3001250 0GAE75-10-001SBL419025R87001.2601 1GAE75-10-111SBL419025R87111.3002200 0GAE75-10-001SBL419025R88001.2601 1GAE75-10-111SBL419025R88111.3002400 0GAE75-10-001SBL419025R89001.2601 1GAE75-10-111SBL419025R89111.300(1) Other control voltages see voltage codes table.82 3.23"12 0.47"110.43"110 4.33"11 0.43"100.39"6.50.26"60.24"10 0.39"40.16"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"72 2.83"72 2.83"GAE75-10-11Main dimensions mm, inches03
1SFC101023C0201 - Rev. A3/180ABB MOTOR PROTECTION AND CONTROL—GAF185 ... GAF300 3-pole contactors250 to 400 A DC-1AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsGAF185 ... GAF300 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately. •main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection polarities must be respected.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 3 coils to cover control voltages between 48...250 V 50/60 Hz and 20...250 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUcAuxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational current θ ≤ 55 °C1000 VDC-1General use ratingθ ≤ 40 °C1000 V DCAAV 50/60 HzV DCkg250250-20...601 1GAF185-10-11 (1)1SFL497025R72113.60048...13048...1301 1GAF185-10-111SFL497025R69113.600100...250 100...2501 1GAF185-10-111SFL497025R70113.600400400-20...601 1GAF300-10-11 (1)1SFL557025R72116.20048...13048...1301 1GAF300-10-111SFL557025R69116.200100...250 100...2501 1GAF300-10-111SFL557025R70116.200(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.ø 8.5 0.33"120.47"17.50.69"105 4.13"111.5 4.39"351.38"10 0.39"187 7.36"160 6.3"35.51.4"196 7.72"5 0.2"43.75 1.72"ø 10.20.4"219 8.62"14 0.55"140 5.51"120.47"17.5 0.69"5 0.2"180.5 7.11"35.5 1.4"227 8.94"GAF185GAF3001SFC101098F0001GAF185-10-111SFC101099F0001GAF300-10-11Main dimensions mm, inches03
1SFC101024C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/181—GAF460 ... GAF750 3-pole contactors600 to 875 A DC-1 AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsGAF460 ... GAF750 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately. • main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection polarities must be respected.• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUcAuxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 55 °C1000 VDC-1General use ratingθ ≤ 40 °C1000 V DCAAV 50/60 HzV DCkg600650-24...601 1GAF460-10-11 (1)1SFL597025R681112.00048...13048...1301 1GAF460-10-111SFL597025R691112.000100...250 100...2501 1GAF460-10-111SFL597025R701112.000250...500 250...5001 1GAF460-10-111SFL597025R711112.000875900-24...601 1GAF750-10-11 (1)1SFL637025R681115.00048...13048...1301 1GAF750-10-111SFL637025R691115.000100...250 100...2501 1GAF750-10-111SFL637025R701115.000250...500 250...5001 1GAF750-10-111SFL637025R711115.000(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.GAF460 ... GAF750 are equipped with low voltage inputs for control, for example by a PLC.Control inputs63 2.48"186 7.32"25 0.98"22.5 0.89"11.5 0.45"268 10.55"ø10.5 0.41"ø6.5 0.26"216 8.5"48.5 1.91"6 0.24"278 10.94"72 2.83"210 8.27"40 1.57"22.50.89"11.5 0.45"273 10.75"ø12.50.49"ø6.50.26"242 9.53"48.5 1.91"6 0.24"283 11.14"GAF460GAF7501SFC101100F0001GAF460-10-111SFC101102F0001GAF750-10-11Main dimensions mm, inches03
1SFC101025C0201 - Rev. B3/182ABB MOTOR PROTECTION AND CONTROL—GAF1250 ... GAF2050 3-pole contactors1040 to 1750 A DC-1AC / DC operated with 1 N.O. + 1 N.C. auxiliary contactsGAF1250 ... GAF2050 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately. •main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection polarities must be respected.•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).•built-in surge suppression•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL / CSARated control circuit voltageUcAuxiliary contacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational currentθ ≤ 55 °C1000 VDC-1General use ratingθ ≤ 40 °C1000 VAAV 50/60 HzV DCkg10401210-24...601 1GAF1250-10-111SFL647025R681116.00048...13048...1301 1GAF1250-10-111SFL647025R691116.000100...250 100...2501 1GAF1250-10-111SFL647025R701116.000250...500 250...5001 1GAF1250-10-111SFL647025R711116.00014501650100...250 100...2501 1GAF1650-10-111SFL677025R701135.00017502050100...250 100...2501 1GAF2050-10-111SFL707025R701135.000GAF1250 ... AF2050 are equipped with low voltage inputs for control, for example by a PLCControl inputs242 9.53"46.58 0.31"18.3"1SFC101125F000150 1.97"72 2.83"72 2.83"210 8.27"344 13.54"313 12.32"263 10.35"72 2.83"ø 7 0.28"ø13 0.51"271.06"1SFC101124F0001249 9.8"136 5.35"136 5.35"80 136 5.35"ø9 0.35"101 438 17.24"392 15.43"312 12.28"471.85"10 0.39"244 9.61"3.15"3.98"40 1.57"2713 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"136 5.35"136 5.35"80136 5.35"ø9 0.35"101438 17.24"392 15.43"312 12.28"47 1.85"10 0.39"244 9.61"3.15"3.98"40 1.57"2713 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"GAF1250GAF1650, GAF20501SFC101004F0201GAF1250-10-111SFC101004F0201GAF1650-10-11136 5.35"136 5.35"80136 5.35"ø9 0.35"101438 17.24"392 15.43"312 12.28"471.85"10 0.39"244 9.61"3.15"3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"GAF1650GAF2050Main dimensions mm, inches03
1SBC101982S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/183—GA75 ... GAF2050 contactorsTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC operatedGA75DC operatedGAE75AC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.1000 V DCDC-1 Utilization category, L/R ≤ 1 msFor air temperature close to contactorIe / Rated operational current DC-1θ ≤ 40 °C220 V 120 A275 A500 A700 A1050 A1250 A1650 A2050 A440 V 100 A275 A500 A700 A1050 A1250 A1650 A2050 A600 V 75 A275 A500 A700 A1050 A1250 A1650 A2050 A1000 V 35 A275 A500 A700 A1050 A1250 A1650 A2050 Aθ ≤ 55 °C220 V 100 A250 A400 A600 A875 A1040 A1450 A1750 A440 V 100 A250 A400 A600 A875 A1040 A1450 A1750 A600 V 75 A250 A400 A600 A875 A1040 A1450 A1750 A1000 V 35 A250 A400 A600 A875 A1040 A1450 A1750 Aθ ≤ 70 °C220 V 85 A180 A325 A480 A720 A875 A1270 A1500 A 440 V 85 A180 A325 A480 A720 A875 A1270 A1500 A 600 V 75 A180 A325 A480 A720 A875 A1270 A1500 A 1000 V 35 A180 A325 A480 A720 A875 A1270 A1500 A With conductor cross-sectional area (3)(1)150 mm²300 mm²(2)2x 240 mm²2x 50x8 mm²2x 100x5 mm²3x 100x5 mm²4x 100x5 mm²DC-3 Utilization category, L/R ≤ 2 msIe / Rated operational current DC-3θ ≤ 55 °C220 V 100 A-440 V 85 A-DC-5 Utilization category, L/R ≤ 7.5 msIe / Rated operational current DC-5θ ≤ 55 °C220 V 85 A-440 V 35 A-Maximum electrical switching frequency300 cycles/h(1) Refer to IEC 60947-1, table 9.(2) For currents up to 370 A, use 2 x LP300 kits.For higher currents, use 300 mm² conductors of minimum length 500 mm together with terminal extension/enlargement (LX300/LW300).(3) To minimize terminal temperature for GAF185 ... GAF2050, length of connection should be at least 0.5 m per pole.Main pole - Utilization characteristics according to UL / CSAContactor typesAC operatedGA75DC operatedGAE75AC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050StandardsUL 508, CSA C22.2 N°14UL 60947-4-1, CSA C22.2 N°60947.4-1Maximum operational voltage1000 V DCUL / CSA DC general use ratingθ ≤ 40 °C440 V 100 A250 A400 A650 A900 A1210 A1650 A2050 A600 V 75 A250 A400 A650 A900 A1210 A1650 A2050 A1000 V 35 A250 A400 A650 A900 A1210 A1650 A2050 AMaximum electrical switching frequency300 cycles/h03
1SBC101983S0201 - Rev. A—GA75 and GAE75 contactorsTechnical dataGeneral technical dataContactor typesAC operatedGA75DC operatedGAE75Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL600 VRated impulse withstand voltage Uimp.8 kVAmbient air temperature close to contactorOperation-40...+70 °CStorage-60...+80 °CClimatic withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification IIMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cycles (5 millions for GAE75)Max. switching frequency3600 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionA20 gB1 10 g closed position / 5 g open position B2 15 gC1 20 gC2 20 g033/184ABB MOTOR PROTECTION AND CONTROL
1SFC101178C0201 - Rev. A—GAF185 ... GAF2050 contactorsTechnical dataGeneral technical dataContactor typesAC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050Rated insulation voltage Uiacc. to IEC 60947-4-11000 Vacc. to UL600 VRated impulse withstand voltage Uimp.8 kVAmbient air temperature close to contactorOperation-40 to +70 °CStorage-40 to +70 °CClimatic withstandacc. to IEC 60068-2-30Maximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles5 millions operating cycles0.5 millions operating cyclesMax. switching frequency300 cycles/h60 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1ABBShock direction1/2 sinusoidal shock for 30 ms: no change in contact position, closed or open positionA5 g-B1 5 g-B2 5 g-C1 5 g-C2 5 g-03ABB MOTOR PROTECTION AND CONTROL 3/185
1SBC101981S0201 - Rev. A—GA75 and GAE75 contactors Technical dataMagnet system characteristicsContactor typesAC operatedGA75Coil operating limitsAC supplyAt θ ≤ 55 °C 0.85...1.1 x Ucacc. to IEC 60947-4-1Please also refer to "Mounting characteristics and conditions for use"AC control voltageRated control circuit voltage Ucat 50 Hz 24...690 Vat 60 Hz 24...690 VCoil consumptionAverage pull-in value50 Hz 180 VA60 Hz 210 VA50/60 Hz (1) 190 VA / 180 VAAverage holding value50 Hz 18 VA / 5.5 W60 Hz 18 VA / 5.5 W50/60 Hz (1) 18 VA / 5.5 WDrop-out voltageApprox. 40...65 % of UcOperating timeBetween coil energization and:N.O. contact closing 8...27 msN.C. contact opening 7...22 msBetween coil de-energization and:N.O. contact opening 4...11 msN.C. contact closing 7...14 ms(1) 50/60 Hz coils: see "Voltage code table".Magnet system characteristicsContactor typesDC operatedGAE75Coil operating limitsAC supplyAt θ ≤ 55 °C 0.85...1.1 x Ucacc. to IEC 60947-4-1Please also refer to "Mounting characteristics and conditions for use"DC control voltageRated control circuit voltage Uc12...250 V DCCoil consumptionAverage pull-in value200 WAverage holding value4 WDrop-out voltageApprox. 15...40 % of UcCoil time constantOpenL/R3 msClosedL/R15 msOperating timeBetween coil energization and:N.O. contact closing 13...30 msN.C. contact opening 10...27 msBetween coil de-energization and:N.O. contact opening (1) 5...15 msN.C. contact closing (1) 8...18 ms(1) The use of surge suppressors increases the opening time with a factor of 1.1 to 1.5 for a RV5 surge suppressor and a factor of 1.5 to 3 for RT5 surge suppressor.Mounting characteristics and conditions for useContactor typesAC operatedGA75DC operatedGAE75Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Control voltage / Ambient temperatureMounting positions1, 1±30°, 2, 3, 4, 5at θ ≤ 55 °C 0.85...1.1 x Ucat θ ≤ 70 °CUc6at θ ≤ 55 °C 0.95...1.1 x Ucat θ ≤ 70 °CUnauthorizedMounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 15 mm or 75 x 25 mmBy screws (not supplied)2 x M6 screws placed diagonally033/186ABB MOTOR PROTECTION AND CONTROL
1SFC101177C0201—GAF185 ... GAF2050 contactorsTechnical dataMagnet system characteristicsContactor typesAC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050Coil operating limitsAC or DC supplyAt θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.Please also refer to "Mounting characteristics and conditions for use"acc. to IEC 60947-4-1AC control voltage 50/60 HzRated control circuit voltage Uc48...250 V AC48...500 V AC100...250 V ACCoil consumptionAverage pull-in value430 VA470 VA890 VA850 VA1900 VAAverage holding value12 VA / 3.5 W 10 VA / 2.5 W 12 VA / 4 W12 VA / 4.5 W48 VA / 17 WDC control voltageRated control circuit voltage Uc20...250 V DC24...500 V DC100...250 V DCCoil consumptionAverage pull-in value500 W520 W990 W950 W1700 WAverage holding value2 W4 W4.5 W16 WDrop-out voltage55 % of Uc min.Dips withstand-20 °C ≤ θ ≤ +60 °C≥ 20 msOperating timeCoil supply between A1 - A2Between coil energization and:N.O. contact closing 30...115 ms50...120 ms50...80 msN.C. contact opening 30...115 ms50...120 ms50...80 msBetween coil de-energization and:N.O. contact opening 25...80 ms33...70 ms35...55 msN.C. contact closing 25...80 ms33...70 ms35...55 msControl input for PLC'sBetween coil energization and:N.O. contact closing-40...60 ms40...90 ms40...65 msN.C. contact opening-40...60 ms40...90 ms40...65 msBetween coil de-energization and:N.O. contact opening-10...30 ms10...30 msN.C. contact closing-10...30 ms10...30 msMounting characteristics and conditions for useContactor typesAC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050Mounting positionsPos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Control voltage / Ambient temperatureMounting positions1, 1±30°, 2, 3, 4, 5 at θ ≤ 70 °C0.85 x Uc min...1.1 x Uc max.6UnauthorizedMounting distancesThe contactors can be assembled side by sideFixingOn rail according to IEC 60715, EN 60715–By screws (not supplied)4 x M54 x M64 x M803 ABB MOTOR PROTECTION AND CONTROL 3/187
1SBC101984S02013/188 ABB MOTOR PROTECTION AND CONTROL—GA75 and GAE75 contactorsTechnical dataConnecting characteristicsContactor typesAC operatedGA75DC operatedGAE75Main terminalsScrew terminals with single connector (13 x 10 mm)Connection capacity (min. ... max.)Main conductors (poles)RigidSolid (≤ 4 mm²)1 x 6...50 mm²Stranded (≥ 6 mm²)2 x 6...25 mm²Flexible with ferrule1 x 6...35 mm²2 x 6...16 mm²LlBars or lugsL ≤–l >–Connection capacity acc. to UL/CSA1 or 2 x AWG 8...1Tightening torqueRecommended4.00 Nm / 35 lb.inMax.4.50 NmAuxiliary conductors(coil terminals)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 1...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 8 mml >3.7 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Tightening torqueCoil terminalsRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP10Coil terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM6Screwdriver typeFlat Ø 6.5 / Pozidriv 2Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
1SFC101179C0201 ABB MOTOR PROTECTION AND CONTROL 3/189—GAF185 ... GAF2050 contactorsTechnical dataConnecting characteristicsContactor typesAC / DC operatedGAF185GAF300GAF460GAF750GAF1250GAF1650GAF2050Main terminalsFlat type517.5ø 8.5ø 10.2205ø 10.525ø 6.522.56AF1250AF750ø 12.540ø 6.522.56508ø 13272515.5AF2050AF165080104040171710ø 138010274030Connection capacity (min. ... max.)Main conductors (poles)Rigid with connectorSingle for Cu cable6...185 mm²16...240 mm²240 mm²300 mm²–Single for Al/Cu cable25...150 mm² 120...240 mm²240 mm²300 mm²–Double for Al/Cu cable–2 x 95...120 mm² 2 x 240 mm²3 x 185 mm²–LøBars or lugsL ≤ 24 mm32 mm47 mm52 mm100 mmØ >8 mm10 mm10 mm12 mm12 mmConnection capacity acc. to UL/CSA1 or 2 x 6 - 250 MCM4 - 500 MCM2//250 - 500 MCM 3// 2/0 - 500 MCM1/0 - 750 MCMTightening torqueRecommended18 Nm /160 Ib.in28 Nm /247 lb.in35 Nm /310 Ib.in45 Nm /398 lb.in45 Nm /398 lb.inMax.20 Nm30 Nm40 Nm49 Nm49 NmAuxiliary conductors(coil terminals)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 8 mml >3.7 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Tightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP00Coil terminalsIP20Screw terminalsMain terminalsM8M10M10M12Screws and boltsCoil terminals (delivered in open position)M3.5Screwdriver typeFlat Ø 5.5 mm / Pozidriv 203
—Contactors for capacitor switching3/192 Overview UA16..RA up to UA110..RA - Unlimited peak current Î3/194 Ordering details3/197 Main accessories3/198 Technical dataUA16 up to UA110 Peak current Î ≤ 100 times the rms current3/200 Ordering details3/203 Main accessories3/204 Technical data3/404 Voltage code table— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310ABB MOTOR PROTECTION AND CONTROL 3/19103
—Contactors for capacitor switchingAC-6b utilization category according to IEC 60947-4-1Capacitor transient conditionsIn Low Voltage industrial installations, capacitors are mainly used for reactive energy correction (raising the power factor). When these capacitors are energized, overcurrents of high amplitude and high frequencies (3 to 15 kHz) occur during the transient period (1 to 2 ms).The amplitude of these current peaks, also known as "inrush current peaks", depends on the following factors: • The network inductances.• The transformer power and short-circuit voltage.• The type of power factor correction.There are 2 types of power factor correction: fixed or automatic.Fixed power factor correction consists of inserting, in paral-lel on the network, a capacitor bank whose total power is provided by the assembly of capacitors of identical or differ-ent ratings.The bank is energized by a contactor that simultaneously supplies all the capacitors (a single step).The inrush current peak, in the case of fixed correction, can reach 30 times the nominal current of the capacitor bank.E1178DSingle-step capacitor bank scheme Use the AF... contactor ranges.An automatic power factor correction system, on the other hand, consists of several capacitor banks of identical or dif-ferent ratings (several steps), energized separately accord-ing to the value of the power factor to be corrected.An electronic device automatically determines the power of the steps to be energized and activates the relevant contac-tors.The inrush current peak, in the case of automatic correction, depends on the power of the steps already on duty, and can reach 100 times the nominal current of the step to be ener-gized.E1179DMulti-step capacitor bank scheme Use the UA... or UA..R A contactor ranges.Steady state condition dataThe presence of harmonics and the network's voltage tolerance lead to a current, estimated to be 1.3 times the nominal current In of the capacitor, permanently circulating in the circuit.Taking into account the manufacturing tolerances, the exact power of a capacitor can reach 1.15 times its nominal power. Standard IEC 60831-1 Edition 2002 specifies that the capacitor must therefore have a maximum thermal current IT of: IT = 1.3 x 1.15 x In = 1.5 x InConsequences for the contactorsTo avoid malfunctions (welding of main poles, abnormal temperature rise, etc.), contactors for capacitor bank switching must be sized to withstand: • A permanent current that can reach 1.5 times the nominal current of the capacitor bank.• The short but high peak current on pole closing (maximum permissible peak current Î ).Contactor selection tool for capacitor switchingIn a given application, if the user does not know the value of the inrush cur-rent peak, this value can be approximately calculated using the formulas given on the pages "Calculation and dimensioning".Alternatively by the CAPCAL selection tool, available on the ABB Website: www.abb.com/lowvoltage right hand side menu search: "Online product selection tools" select: "Contactors: AC-6b capacitor switching"This program allows the calculation of these peaks and gives the references of the ABB contactors according to the installation specifications. This cal-culation is valid for one or several capacitor banks.3/192 ABB MOTOR PROTECTION AND CONTROL1SBC101603S0201 - Rev. A03
—Contactors for capacitor switchingThe ABB solutions1SBC580783F03031SBC580105F03031SBC587774F03011SBC587794F03011SBC587764F03011SBC591694F03031SBC591444F03021SBC580093F0303ABB offers 2 contactor versions according to the value of the inrush current peak and the power of the capacitor bank.UA contactors for capacitor switching (UA16 to UA110)UA..RA contactors for capacitor switching (UA16..RA to UA110..RA) with insertion of damping resistorsThe insertion of damping resistors protects the contactor and the capacitor from the highest inrush currents.Maximum permissible peak current Î ≤ 100 times the nominal rms current of the switched capacitor. ABB MOTOR PROTECTION AND CONTROL 3/1931SBC101604S0201 - Rev. A03
1SBC587794F0301UA16-30-10RA1SBC587774F0301UA30-30-10RA—UA16..RA ... UA30..RA 3-pole contactors for capacitor switching12.5 to 30 kvar - Unlimited peak current ÎAC operatedUA..RA contactors for capacitor switching can be used for installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances.The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making.These contactors are of the block type design with:•3 main poles and 1 built-in auxiliary contact •the UA..RA contactors are fitted with a special front-mounted block, which ensures the serial in-sertion of 3 damping resistors into the circuit to limit the current peak on energization of the ca-pacitor bank - their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles - the insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.• control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational powerRated operational powerθ ≤ 40 °Cθ ≤ 40 °C400 V480 VAC-6bkvarkvarV 50 HzV 60 Hzkg12.51624241 0UA16-30-10RA1SBL181024R81100.460110110...1201 0UA16-30-10RA1SBL181024R84100.460220...230 230...2401 0UA16-30-10RA1SBL181024R80100.460230...240 240...2601 0UA16-30-10RA1SBL181024R88100.460380...400400...4151 0UA16-30-10RA1SBL181024R85100.460400...415 415...4401 0UA16-30-10RA1SBL181024R86100.460222224241 0UA26-30-10RA1SBL241024R81100.710110110...1201 0UA26-30-10RA1SBL241024R84100.710220...230 230...2401 0UA26-30-10RA1SBL241024R80100.710230...240 240...2601 0UA26-30-10RA1SBL241024R88100.710380...400400...4151 0UA26-30-10RA1SBL241024R85100.710400...415 415...4401 0UA26-30-10RA1SBL241024R86100.710302824241 0UA30-30-10RA1SBL281024R81100.810110110...1201 0UA30-30-10RA1SBL281024R84100.810220...230 230...2401 0UA30-30-10RA1SBL281024R80100.810230...240 240...2601 0UA30-30-10RA1SBL281024R88100.810380...400400...4151 0UA30-30-10RA1SBL281024R85100.810400...415 415...4401 0UA30-30-10RA1SBL281024R86100.810(1) Other control voltages see voltage code table.68 2.68"47 1.85"107 4.21"5.5 0.22"4 0.16"35 mm EN/IEC 60715+10+.394"120 4.72"44 1.73"74 2.91"UA16..RA47 1.85"87.3 3.44"126.3 4.97"9 0.35"4 0.16"35 mm EN/IEC 60715+10120 4.72"+.394"54 2.13"90 3.54"UA26..RA102 4.02"9 0.35"4 0.16"47 1.85"130 5.12"+10+.394"141 5.55"35 mm EN/IEC 6071554 2.13"90 3.54"UA30..RAMain dimensions mm, inches3/194ABB MOTOR PROTECTION AND CONTROL1SBC101507S0201 - Rev. A03
1SBC587764F0301UA75-30-00 RA—UA50..RA ... UA75..RA 3-pole contactors for capacitor switching40 to 60 kvar - Unlimited peak current ÎAC operatedUA..RA contactors for capacitor switching can be used for installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances.The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. These contactors are of the block type design with:•3 main poles •the UA..RA contactors are fitted with a special front-mounted block, which ensures the serialinsertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank - their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles - the insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.• control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational powerθ ≤ 40 °C400 VAC-6bRated operational powerθ ≤ 40 °C480 VkvarkvarV 50 Hz V 60 Hzkg405024240 0UA50-30-00RA1SBL351024R81001.350110110...1200 0UA50-30-00RA1SBL351024R84001.350220...230 230...2400 0UA50-30-00RA1SBL351024R80001.350230...240 240...2600 0UA50-30-00RA1SBL351024R88001.350380...400400...4150 0UA50-30-00RA1SBL351024R85001.350400...415 415...4400 0UA50-30-00RA1SBL351024R86001.350505524240 0UA63-30-00RA1SBL371024R81001.350110110...1200 0UA63-30-00RA1SBL371024R84001.350220...230 230...2400 0UA63-30-00RA1SBL371024R80001.350230...240 240...2600 0UA63-30-00RA1SBL371024R88001.350380...400400...4150 0UA63-30-00RA1SBL371024R85001.350400...415 415...4400 0UA63-30-00RA1SBL371024R86001.350606424240 0UA75-30-00RA 1SBL411024R81001.350110110...1200 0UA75-30-00RA1SBL411024R84001.350220...230 230...2400 0UA75-30-00RA1SBL411024R80001.350230...240 240...2600 0UA75-30-00RA1SBL411024R88001.350380...400400...4150 0UA75-30-00RA1SBL411024R85001.350400...415 415...4400 0UA75-30-00RA1SBL411024R86001.350(1) Other control voltages see voltage code table.6 0.24"10 0.39"4 0.16"75 mm EN/IEC 6071535 mm x 15 EN/IEC 60715140.4 5.53"47 1.85"+10+10"150 5.91"101.5 4"70 2.76"110 4.33"114 4.49"UA50..RA, UA63..RA, UA75..RAMain dimensions mm, inchesABB MOTOR PROTECTION AND CONTROL 3/1951SBC101508S0201 - Rev. A03
1SBC591444F0302UA110-30-00 RA—UA95..RA ... UA110..RA 3-pole contactors for capacitor switching70 to 80 kvar - Unlimited peak current ÎAC operatedUA..RA contactors for capacitor switching can be used for installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances.The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. These contactors are of the block type design with:•3 main poles •the UA..RA contactors are fitted with a special front-mounted block, which ensures the serialinsertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank - their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles - the insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.• control circuit: AC operated•add-on auxiliary contact blocks for side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational powerθ ≤ 40 °C400 VAC-6bRated operational powerθ ≤ 40 °C480 VV 50 Hz V 60 Hzkg708024240 0UA95-30-00RA1SFL431024R81002.000110110...1200 0UA95-30-00RA1SFL431024R84002.000220...230 230...2400 0UA95-30-00RA1SFL431024R80002.000230...240 240...2600 0UA95-30-00RA1SFL431024R88002.000380...400400...4150 0UA95-30-00RA1SFL431024R85002.000400...415 415...4400 0UA95-30-00RA1SFL431024R86002.000809524240 0UA110-30-00RA1SFL451024R81002.000110110...1200 0UA110-30-00RA1SFL451024R84002.000220...230 230...2400 0UA110-30-00RA1SFL451024R80002.000230...240 240...2600 0UA110-30-00RA1SFL451024R88002.000380...400400...4150 0UA110-30-00RA1SFL451024R85002.000400...415 415...4400 0UA110-30-00RA1SFL451024R86002.000(1) Other control voltages see voltage code table.47 1.85"+10+10"170 6.69"114.4 4.5"6 0.24"75 mm EN/IEC 6071510 0.39"155.6 6.13"155.3 6.11"90 3.54"148 5.83"UA95..RA, UA100..RAMain dimensions mm, inches3/196ABB MOTOR PROTECTION AND CONTROL1SBC101553S0201 - Rev. A03
—UA..RA 3-pole contactors for capacitor switchingUnlimited peak current ÎMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMainpolesAvailableauxiliarycontactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksAuxiliary contact blocks1-pole CA5-..2-pole CAL...UA16-30-10RA3 01 0–1 x CAL5-11UA26-30-10RA3 01 0–1 to 2 x CAL5-11UA30-30-10RA3 01 0 1 x CA5-...+ 1 to 2 x CAL5-11UA50-30-00RA3 00 0 1 to 2 x CA5-...+ 1 to 2 x CAL5-11UA63-30-00RA3 00 0UA75-30-00RA3 00 0UA95-30-00RA3 00 0 1 to 2 x CA5-...+ 1 to 2 x CAL18-11UA110-30-00RA3 00 0ABB MOTOR PROTECTION AND CONTROL 3/1971SBC101509S020103
—UA16..RA ... UA110..RA 3-pole contactors for capacitor switchingUnlimited peak current ÎTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC operatedUA16..RAUA26..RAUA30..RAUA50..RAUA63..RAUA75..RAUA95..RAUA110..RAStandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzAC-6b Utilization categoryRated operational power AC-6b (1)For air temperature close to contactorθ ≤ 40 °C230-240 V 8 kvar12.5 kvar16 kvar25 kvar30 kvar35 kvar40 kvar45 kvar400-415 V 12.5 kvar22 kvar30 kvar40 kvar50 kvar60 kvar70 kvar80 kvarMulti-step capacitor bank scheme440 V 15 kvar24 kvar32 kvar50 kvar55 kvar65 kvar75 kvar85 kvar500-550 V 18 kvar30 kvar34 kvar55 kvar65 kvar75 kvar85 kvar95 kvar690 V 22 kvar35 kvar45 kvar72 kvar80 kvar100 kvar120 kvar130 kvar θ ≤ 55 °C230-240 V 7.5 kvar11.5 kvar16 kvar24 kvar27 kvar30 kvar35 kvar40 kvar400-415 V 12.5 kvar20 kvar27.5 kvar40 kvar45 kvar50 kvar60 kvar70 kvar440 V 13 kvar20 kvar30 kvar43 kvar48 kvar53 kvar65 kvar75 kvar500-550 V 16 kvar25 kvar34 kvar50 kvar60 kvar65 kvar75 kvar82 kvar690 V 21 kvar31 kvar45 kvar65 kvar75 kvar80 kvar105 kvar110 kvarθ ≤ 70 °C230-240 V 6 kvar9 kvar11 kvar20 kvar23 kvar25 kvar30 kvar35 kvar400-415 V 10 kvar15.5 kvar19.5 kvar35 kvar39 kvar41 kvar53 kvar60 kvar440 V 11 kvar17 kvar20.5 kvar37 kvar42.5 kvar45 kvar58 kvar70 kvar500-550 V 12.5 kvar20 kvar25 kvar46 kvar50 kvar55 kvar70 kvar78 kvar690 V 17 kvar26 kvar32 kvar60 kvar65 kvar70 kvar85 kvar100 kvarMax. permissible peak current ÎUnlimitedShort-circuit protection device for contactorsgG type fuse (2)80 A125 A200 A250 AMax. electrical switching frequency240 cycles/hElectrical durability AC-6bUe ≤ 440 V250 000 operating cycles500 V ≤ Ue ≤ 690 V100 000 operating cycles(1) For 220 V and 380 V, multiply by 0.9 the rated values at 230 V and 400 V respectively. Example: 50 kvar / 400 V corresponding to 0.9 x 50 = 45 kvar/380 V.(2) The fuse ratings given represent the maximum ratings ensuring type 1 coordination according to the definition of standard IEC 60947-4-1.Main pole - Utilization characteristics according to UL / CSAContactor typesAC operatedUA16..RAUA26..RAUA30..RAUA50..RAUA63..RAUA75..RAUA95..RAUA110..RAPower - 60 HzFor air temperature close to contactorθ ≤ 40 °C240 V 8 kvar11 kvar14 kvar25 kvar27.5 kvar32 kvar40 kvar45 kvar480 V 16 kvar22 kvar28 kvar50 kvar55 kvar64 kvar80 kvar95 kvar600 V 20 kvar27 kvar35 kvar62 kvar70 kvar80 kvar100 kvar120 kvarMax. permissible peak Current ÎUnlimitedOperating principleThe front-mounted block mechanism of the UA..RA contactors ensures:•early making of the auxiliary "PA" poles with respect to the main "PP" poles•automatic return to the open position of the auxiliary "PA" poles after the main poles are closed.When the coil is energized, the early making auxiliary poles connect the capacitor to the network via the set of 3 resistors. The damping resistors attenuate the first current peak and the second inrush current when the main contacts begin to make. Once the main poles are in the closed position, the auxiliary poles automatically break.When the coil is de-energized, the main poles break ensuring the breaking of the capacitor bank.The contactor can then begin a new cycle.The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.A1A2PARPPRCCoil voltageUcAux. polesPAMain polesPPTotalclosing time1SBC101510S0201 - Rev. A033/198ABB MOTOR PROTECTION AND CONTROL
Connecting characteristicsContactor typesAC operatedUA16..RAUA26..RAUA30..RAUA50..RAUA95..RAUA63..RAUA110..RAUA75..RAConnection capacity (min. ... max.)Main conductors (poles)RigidSolid (≤ 4 mm²)1 x 1...4 mm²1.5...6 mm²2.5...16 mm²6...50 mm²10...95 mm²Stranded (≥ 6 mm²)2 x--2.5...16 + 2.5...6 mm² 6...25 + 6...16 mm²6...35 mm²Flexible with ferrule1 x 0.75...2.5 mm²1.5...4 mm²2.5...10 mm²6...35 mm²10...70 mm²2 x--2.5...10 + 2.5...4 mm² 6...16 + 6...10 mm²6...35 mm²LlBars or lugsL ≤ 7.7 mm10 mm---l >3.7 mm4.2 mm---Connection capacity acc. to UL/CSA1 or 2 x AWG 18...10AWG 12...8AWG 8...4AWG 8...1AWG 6...2/0Tightening torqueRecommended1 Nm / 9 Ib.in1.7 Nm / 15 Ib.in2.3 Nm / 20 Ib.in4 Nm / 35 Ib.in8 Nm / 53 Ib.inMax.1.2 Nm2.2 Nm2.6 Nm4.5 Nm9 NmAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 1...4 mm²0.75...2.5 mm²2 x 1...4 mm²0.75...2.5 mm²Flexible with ferrule1 x 0.75...2.5 mm²1...2.5 mm²0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsCoil terminalsL ≤ 8 mml >3.7 mmBuilt-in auxiliaryL ≤ 7.7 mm10 mm8 mm--terminalsl >3.7 mm4.2 mm3.7 mm--Connection capacity acc. to UL/CSA1 or 2 x AWG 18...14Tightening torqueCoil terminalsRecommended1 Nm / 9 Ib.inMax.1.2 NmBuilt-in auxiliary terminalsRecommended1 Nm / 9 Ib.inMax.1.2 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20IP10Coil terminalsIP20Built-in auxiliary terminalsIP20--Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM 3.5 M 4M 5M6M8Screwdriver typeFlat Ø 5.5 / Pozidriv 2Flat Ø 6.5 / Pozidriv 2Hexagon socket (s = 4 mm)Coil terminalsM 3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Built-in auxiliary terminalsM 3.5M 4M 3.5--Screwdriver typeFlat Ø 5.5 / Pozidriv 2--Other technical characteristics are the same as those of standard A contactors.—UA16..RA ... UA110..RA 3-pole contactors for capacitor switchingUnlimited peak current ÎTechnical data ABB MOTOR PROTECTION AND CONTROL 3/1991SBC101513S020103
1SBC591694F0304UA16-30-101SBC580093F0303UA30-30-10—UA16 ... UA30 3-pole contactors for capacitor switching12.5 to 27.5 kvar - Peak current Î ≤ 100 times the rms currentAC operatedUA contactors can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current.The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making.These contactors are of the block type design with:•3 main poles and 1 built-in auxiliary contact •control circuit: AC operated•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Rated operational powerθ ≤ 40 °C400 VAC-6bMax peak currentÎRated operational powerθ ≤ 40 °C480 VkvarkAkvarV 50 HzV 60 Hzkg12.51.8-24241 0UA16-30-101SBL181022R81100.34048481 0UA16-30-101SBL181022R83100.340110110...1201 0UA16-30-101SBL181022R84100.340220...230 230...2401 0UA16-30-101SBL181022R80100.340230...240 240...2601 0UA16-30-101SBL181022R88100.340380...400400...4151 0UA16-30-101SBL181022R85100.340400...415 415...4401 0UA16-30-101SBL181022R86100.3402032524241 0UA26-30-101SBL241022R81100.60048481 0UA26-30-101SBL241022R83100.600110110...1201 0UA26-30-101SBL241022R84100.600220...230 230...2401 0UA26-30-101SBL241022R80100.600230...240 240...2601 0UA26-30-101SBL241022R88100.600380...400400...4151 0UA26-30-101SBL241022R85100.600400...415 415...4401 0UA26-30-101SBL241022R86100.60027.53.53224241 0UA30-30-101SBL281022R81100.71048481 0UA30-30-101SBL281022R83100.710110110...1201 0UA30-30-101SBL281022R84100.710220...230 230...2401 0UA30-30-101SBL281022R80100.710230...240 240...2601 0UA30-30-101SBL281022R88100.710380...400400...4151 0UA30-30-101SBL281022R85100.710400...415 415...4401 0UA30-30-101SBL281022R86100.710(1) Other control voltages see voltage code table.44 1.73"74 2.91"68 2.68"74 2.91"5.5 0.22"4 0.16"10 0.39"35 mm EN/IEC 60715UA164 0.16"10 0.39"6.3 0.25"93.6 3.69"9 0.35"35 mm EN/IEC 6071554 2.13"90 3.54"UA26108.3 4.26"9 0.35"6.3 0.25"4 0.16"10 0.39"35 mm EN/IEC 6071554 2.13"90 3.54"UA30Main dimensions mm, inches3/200ABB MOTOR PROTECTION AND CONTROL1SBC101514S020103
1SBC580783F0303UA50-30-00—UA50 ... UA75 3-pole contactors for capacitor switching33 to 50 kvar - Peak current Î ≤ 100 times the rms currentAC operatedUA contactors can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current.The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making.These contactors are of the block type design with:• 3 main poles• control circuit: AC operated• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Ratedoperationalpowerθ ≤ 40 °C400 VAC-6bMaxpeakcurrentÎRatedoperationalpowerθ ≤ 40 °C480 VkvarkAkvarV 50 HzV 60 Hzkg3354024240 0UA50-30-001SBL351022R81001.16048480 0UA50-30-001SBL351022R83001.160110110...1200 0UA50-30-001SBL351022R84001.160220...230 230...2400 0UA50-30-001SBL351022R80001.160230...240 240...2600 0UA50-30-001SBL351022R88001.160380...400400...4150 0UA50-30-001SBL351022R85001.160400...415 415...4400 0UA50-30-001SBL351022R86001.160456.5-24240 0UA63-30-001SBL371022R81001.16048480 0UA63-30-001SBL371022R83001.160110110...1200 0UA63-30-001SBL371022R84001.160220...230 230...2400 0UA63-30-001SBL371022R80001.160230...240 240...2600 0UA63-30-001SBL371022R88001.160380...400400...4150 0UA63-30-001SBL371022R85001.160400...415 415...4400 0UA63-30-001SBL371022R86001.160507.55524240 0UA75-30-001SBL411022R81001.16048480 0UA75-30-001SBL411022R83001.160110110...1200 0UA75-30-001SBL411022R84001.160220...230 230...2400 0UA75-30-001SBL411022R80001.160230...240 240...2600 0UA75-30-001SBL411022R88001.160380...400400...4150 0UA75-30-001SBL411022R85001.160400...415 415...4400 0UA75-30-001SBL411022R86001.160(1) Other control voltages see voltage code table.70 2.76"110 4.33"6.5 0.26"6 0.24"10 0.39"40.16"10 0.39"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"UA50, UA63, UA75Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 3/2011SBC101521S020103
—UA95 ... UA110 3-pole contactors for capacitor switching65 to 75 kvar - Peak current Î ≤ 100 times the rms currentAC operatedUA contactors can be used for the switching of capacitor banks whose inrush current peaks are less or equal to 100 times nominal rms current. The capacitors must be discharges (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making.These contactors are of the block type design with:•3 main poles•control circuit: AC operated•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.IECUL/CSARated control circuitvoltageUc(1)Auxiliarycontacts fittedTy pe Order codeWeightPkg(1 pce)Ratedoperationalpowerθ ≤ 40 °C400 VAC-6bMaxpeakcurrentÎRatedoperationalpowerθ ≤ 40 °C480 VkvarkAkvarV 50 HzV 60 Hzkg659.37024240 0UA95-30-001SFL431022R81002.00048480 0UA95-30-001SFL431022R83002.000110110...1200 0UA95-30-001SFL431022R84002.000220...230 230...2400 0UA95-30-001SFL431022R80002.000230...240 240...2600 0UA95-30-001SFL431022R88002.000380...400400...4150 0UA95-30-001SFL431022R85002.000400...415 415...4400 0UA95-30-001SFL431022R86002.0007510.58024240 0UA110-30-001SFL451022R81002.00048480 0UA110-30-001SFL451022R83002.000110110...1200 0UA110-30-001SFL451022R84002.000220...230 230...2400 0UA110-30-001SFL451022R80002.000230...240 240...2600 0UA110-30-001SFL451022R88002.000380...400400...4150 0UA110-30-001SFL451022R85002.000400...415 415...4400 0UA110-30-001SFL451022R86002.000(1) Other control voltages see voltage code table.1SBC580105F0303UA110-30-0090 3.54"148 5.83"123.5 4.86"6 0.24"20 0.79" 10 0.39"6.5 0.26"UA95, UA110 Main dimensions mm, inches3/202ABB MOTOR PROTECTION AND CONTROL1SFC101059C020103
—UA... 3-pole contactors for capacitor switchingPeak current Î ≤ 100 times the rms currentMain accessory fitting detailsMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMainpolesAvailableauxiliarycontactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksPneumatic timerAuxiliary contact blocks1-pole CA5-..4-pole CA5-..T P. . A2-pole CAL...UA16-30-103 01 01 to 4 x CA5-..or1 x CA5-.. (4-pole)or1 x TP.. A+1 to 2 x CAL5-11UA26-30-103 01 01 to 4 x CA5-..or1 x CA5-.. (4-pole)or1 x TP.. A+1 to 2 x CAL5-11UA30-30-103 01 01 to 5 x CA5-..or1 x CA5-.. (4-pole)or1 x TP.. A+1 to 2 x CAL5-11+ 1 x 1-pole CA5-..+ 1 x CA5-.. (1-pole)UA50-30-003 00 01 to 6 x CA5-..or1 x CA5-.. (4-pole)or1 x TP.. A+1 to 2 x CAL5-11UA63-30-003 00 0+ 2 x 1-pole CA5-..+ 2 x CA5-.. (1-pole)UA75-30-003 00 0UA95-30-003 00 01 to 6 x CA5-..or1 x CA5-.. (4-pole)–+1 to 2 x CAL18-11UA110-30-003 00 0+ 2 x 1-pole CA5-.. ABB MOTOR PROTECTION AND CONTROL 3/2031SBC101533S020103
—UA16 ... UA110 3-pole contactors for capacitor switchingPeak current Î ≤ 100 times the rms currentTechnical dataMain pole - Utilization characteristics according to IECContactor typesAC operatedUA16UA26UA30UA50UA63UA75UA95UA110StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzAC-6b Utilization categoryRated operational power AC-6b (1)For air temperature close to contactorθ ≤ 40 °C230-240 V 7.5 kvar12 kvar16 kvar20 kvar25 kvar30 kvar35 kvar40 kvar400-415 V 12.5 kvar20 kvar27.5 kvar33 kvar45 kvar50 kvar65 kvar75 kvarMulti-step capacitor bank scheme440 V 13.7 kvar22 kvar30 kvar36 kvar50 kvar55 kvar65 kvar75 kvar500-550 V 15.5 kvar22 kvar34 kvar40 kvar50 kvar62 kvar70 kvar80 kvar690 V 21.5 kvar30 kvar45 kvar55 kvar70 kvar75 kvar80 kvar90 kvar θ ≤ 55 °C230-240 V 6.7 kvar11 kvar16 kvar20 kvar25 kvar30 kvar35 kvar40 kvar400-415 V 11.7 kvar18.5 kvar27.5 kvar33 kvar43 kvar50 kvar65 kvar70 kvar440 V 13 kvar20 kvar30 kvar36 kvar48 kvar53 kvar65 kvar75 kvar500-550 V 14.7 kvar22 kvar34 kvar40 kvar50 kvar62 kvar70 kvar80 kvar690 V 20 kvar30 kvar45 kvar55 kvar70 kvar75 kvar80 kvar90 kvarθ ≤ 70 °C230-240 V 6 kvar8.5 kvar11 kvar19 kvar21 kvar22 kvar30 kvar35 kvar400-415 V 10 kvar14.5 kvar19 kvar32 kvar37 kvar39 kvar55 kvar65 kvar440 V 11 kvar16 kvar20 kvar35 kvar41 kvar43 kvar55 kvar70 kvar500-550 V 12.5 kvar19.5 kvar23.5 kvar40 kvar45 kvar47.5 kvar60 kvar75 kvar690 V 17 kvar25 kvar32 kvar52 kvar60 kvar65 kvar70 kvar85 kvarMax. permissible peak current ÎUe ≤ 500 V 1.8 kA3 kA3.5 kA5 kA6.5 kA7.5 kA9.3 kA10.5 kAUe > 500 V 1.6 kA2.7 kA3.1 kA4.5 kA5.8 kA6.75 kA8 kA9 kAShort-circuit protection device for contactorsgG type fusesized 1.5...1.8 In of the capacitorMax. electrical switching frequency240 cycles/hElectrical durability AC-6bUe ≤ 690 V100 000 operating cycles(1) For 220 V and 380 V, multiply by 0.9 the rated values at 230 V and 400 V respectively.Example: 50 kvar / 400 V corresponding to 0.9 x 50 = 45 kvar/380 V.If, in an application, the current peak is greater than the maximum peak current Î specified in the tables above, select a higher rating, refer to the UA..R A contactors, or add induc-tances. (see application guide "Contactors for capacitor switching").Main pole - Utilization characteristics according to UL / CSAContactor typesAC operatedUA16UA26UA30UA50UA63UA75UA95UA110Power - 60 HzFor air temperature close to contactorθ ≤ 40 °C240 V-12.5 kvar16 kvar20 kvar-27.5 kvar35 kvar40 kvar480 V-25 kvar32 kvar40 kvar-55 kvar70 kvar80 kvar600 V-30 kvar40 kvar50 kvar-70 kvar75 kvar85 kvarIf, in an application, the current peak is greater than the maximum peak current Î specified in the tables above, select a higher rating, refer to the UA..R A contactors, or add induc-tances. (see application guide "Contactors for capacitor switching").033/204ABB MOTOR PROTECTION AND CONTROL
Connecting characteristicsContactor typesAC operatedUA16UA26UA30UA50UA95UA63UA110UA75Connection capacity (min. ... max.)Main conductors (poles)RigidSolid (≤ 4 mm²)1 x 1...4 mm²1.5...6 mm²2.5...16 mm²6...50 mm²10...95 mm²Stranded (≥ 6 mm²)2 x 1...4 mm²1.5...6 mm²2.5...16 mm²6...25 mm²6...35 mm²Flexible with ferrule1 x 0.75...2.5 mm²0.75...4 mm²2.5...10 mm²6...35 mm²10...70 mm²2 x 0.75...2.5 mm²0.75...4 mm²2.5...10 mm²6...16 mm²6...35 mm²LlBars or lugsL ≤ 7.7 mm10 mm---l >3.7 mm4.2 mm---Connection capacity acc. to UL/CSA1 or 2 x AWG 18...10AWG 12...8AWG 8...4AWG 8...1AWG 6...2/0Tightening torqueRecommended1 Nm / 9 Ib.in1.7 Nm / 15 Ib.in2.3 Nm / 20 Ib.in4 Nm / 35 Ib.in8 Nm / 71 Ib.inMax.1.2 Nm2.2 Nm2.6 Nm4.5 Nm9 NmAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 1...4 mm²0.75...2.5 mm²2 x 1...4 mm²0.75...2.5 mm²Flexible with ferrule1 x 0.75...2.5 mm²1...2.5 mm²0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsCoil terminalsL ≤ 8 mml >3.7 mmBuilt-in auxiliaryL ≤ 7.7 mm10 mm8 mm--terminalsl >3.7 mm4.2 mm3.7 mm--Connection capacity acc. to UL/CSAAWG 18...14Tightening torqueCoil terminalsRecommended1 Nm / 9 Ib.inMax.1.2 NmBuilt-in auxiliary terminalsRecommended1 Nm / 9 Ib.inMax.1.2 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20IP10Coil terminalsIP20Built-in auxiliary terminalsIP20--Screw terminalsDelivered in open position, screws of unused terminals must be tightenedMain terminalsM3.5 M4M5M6M8Screwdriver typeFlat Ø 5.5 / Pozidriv 2Flat Ø 6.5 / Pozidriv 2Hexagon socket (s = 4 mm)Coil terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Built-in auxiliary terminalsM3.5M4M3.5--Screwdriver typeFlat Ø 5.5 / Pozidriv 2--Other technical characteristics are the same as those of standard A contactors.—UA16 ... UA110 3-pole contactors for capacitor switchingPeak current Î ≤ 100 times the rms currentTechnical data ABB MOTOR PROTECTION AND CONTROL 3/2051SBC101537S020103
—NF 4-pole and 8-pole contactor relaysOrdering details 4-pole contactor relays3/208 NF AC / DC operated3/209 NFZ 24 V DC operated designed for PLC3/210 NFZ AC / DC operated for specific applications3/211 Contactor relays and main accessoriesOrdering details 8-pole contactor relays3/212 NF AC / DC operated 3/213 NFZ 24 V DC operated designed for PLC3/214 NFZ AC / DC operated for specific applications3/215 Contactor relays and main accessories3/216 Technical dataOrdering details contactor relays with Push-in Spring terminals3/219 NF..K AC / DC operated3/220 NFZ..K 24 V DC operated designed for PLC3/221 NFZ..K AC / DC operated for specific applications3/222 Contactor relays and main accessories3/223 Technical data3/404 Voltage code table— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310ABB MOTOR PROTECTION AND CONTROL 3/207
NF contactor relays are used for switching auxiliary and control circuits.These contactor relays are of the block type design with:•4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked sym-bol)•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - reduced panel energy consumption - very distinct closing and opening.•built-in surge suppression•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuitvoltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)V 50/60 HzV DCkg43NONO4431NCNC3221NCNC2213NONO14A1A224...6020...60(1)NF22E-111SBH137001R11220.27048...13048...130NF22E-121SBH137001R12220.270100...250100...250NF22E-131SBH137001R13220.270250...500250...500NF22E-141SBH137001R14220.31033NONO3421NCNC2213NONO1443NONO44A1A224...6020...60(1)NF31E-111SBH137001R11310.27048...13048...130NF31E-121SBH137001R12310.270100...250100...250NF31E-131SBH137001R13310.270250...500250...500NF31E-141SBH137001R14310.31043NONO4433NONO3423NONO2413NONO14A1A224...6020...60(1)NF40E-111SBH137001R11400.27048...13048...130NF40E-121SBH137001R12400.270100...250100...250NF40E-131SBH137001R13400.270250...500250...500NF40E-141SBH137001R14400.310(1) NF..-11 not suitable for direct control by PLC-output.45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCNF22E, NF31E, NF40E—NF 4-pole contactor relaysAC / DC operated1SBC101104F0014NF22EMain dimensions mm, inches3/208ABB MOTOR PROTECTION AND CONTROL1SBC101558S0201 - Rev. C03
NFZ contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with:• 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)•control circuit: 24 V DC operated with electronic coil interface allowing low holding consump-tion up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening•built-in surge suppression•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuitvoltageUcTy pe Order codeWeightPkg(1 pce)V DCkg4-pole contactor relays43NONO4431NCNC3221NCNC2213NONO14A1+A2-24NFZ22E-301SBH136001R30220.43033NONO3421NCNC2213NONO1443NONO44A1+A2-24NFZ31E-301SBH136001R30310.43043NONO4433NONO3423NONO2413NONO14A1+A2-24NFZ40E-301SBH136001R30400.430Note: NFZ contactor relays with DC control voltage 24 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.—NFZ 4-pole contactor relays24 V DC operated designed for PLC1SBC101104F0014NFZ22E-30Main dimensions mm, inches45 1.77"80 3.15"6 0.24"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC97 3.82"91 3.58"NFZ22E, NFZ31E, NFZ40EContactors AF..Z-...-30, contactor relays NFZ...-30 and accessoriesSchütze AF..Z-...-30, Hilfsschütze NFZ...-30 und ZubehörContacteurs AF..Z-...-30, contacteurs auxiliaires NFZ...-30 et accessoiresKontaktorer AF..Z-...-30, reläkontaktorer NFZ...-30 och tillbehörContattori AF..Z-...-30, contattori ausiliari NFZ...-30 e accessori Contactores AF..Z-...-30, contactores auxiliares NFZ...-30 y accesoriosAF..Z-...-30,NFZ...-30NFZ...-30, 1SBC101053M6801 - 01/18AF09Z...38Z-..-..-30, NFZ22E-30...NFZ80E-30, CA4, CAL4, LDC4Operating instructionsBetriebsanleitungNotice d'instructionInstruktionIstruzioni tecnicheInstrucciones de empleoABB France3, rue Jean Perrin69680 Chassieu / Francewww.abb.com/lowvoltageZ-...-30,35mm EN/EC 607155.5 0.22"91 3.58"97 3.82" 5.5 0.22"10 0.39"35mm EN/EC 607155.5 0.22"91 3.58"130.5 5.14"5.5 0.22"10 0.39"43 1.69"CLIC !4CLIC !2 AmminchNFZ44E...NFZ80E-30AF09Z...16Z-30-22-30130,5 5.14"AF26Z...38Z-30-22-30AF26Z...38Z-30-11-30139,5 5.49"131,5 5.18" Bmminch91 3.58"100 3.94"100 3.94" Amm inch97 3.82" Bmm inch91 3.58"NFZ22E...NFZ40E-30AF09Z...16Z-...-30 AF26Z...38Z-...-30 3-pole106 4.17"100 3.94"45 1,77" 80 3.15" 6 0.24" 2 0.08"2 0.08" AF09Z...38Z-...-30, NFZ22E...NFZ80E-30Acc. to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, min. enclosure for : AF09Z...AF16Z-...-30, NFZ...-30, : 180 x 130 x 175 mmAF26Z...38Z-30-...-30 3-pole : 255 x 180 x 175 mm35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCpozidriv N° 2M 3,51,2 N.mM 3,51,5 N.m2 x1...62 x1...2,5mm²mm²2 x0,75...62 x0,75...2,5 L < 8L < 9,6Ø 5,5Ø 5,5AF09Z...16Z-...-303 & 4-polemm²2 x 0,75...2,51 x 0,75...4AF09Z ... 38Z-...-30NFZ...-30NFZ...-30AF09Z... 38Z-30-22-30AF26Z... 38Z-30-11-30 M 3,51,2 N.mØ 5,5AF26Z...38Z-...-303-poleM 42,5 N.mØ 6,52 x0,75...2,52 x1...2,52 x2,5...102 x1,5...102 x 0,75...1,51 x 0,75... 2,52 x 0,75....1,51 x 0,75... 2,52 x 1,5...41 x 1,5...10L < 12,5 L < 8L < 9,6LLL = 10L = 14L = 10L = 10mmAF09Z...16Z-30-10-30AF09Z...16Z-30-01-30_____LHmmmm-Uc= 24VDCA1A2NFZ...-30AF09Z...38Z-..-30+AF26/AF30/AF38 AF26/AF30/AF38 AF26/AF30/AF38max Fusemax Fuse60A/RK5Circuit BreakerT4V250 + TM250Circuit BreakerXT1H125 + TM100Circuit BreakerXT2V125 + TM10060A/J52535-654265100AF26According to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, for use on a circuit capable of delivering not more than the max. symmetrical amperes at the max. voltage shown in the table below. WARNING : if opening of BCP, controller shall be examined and replaced if damaged.AF30AF38max Fuse100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)480V (kA)600V (kA)Max Short-circuit at100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)Max Short-circuit at480V, 600V(kA)NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30NFZ31E-30, NFZ22E-30AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30 + max 4 aux contacts / 2NCCA4-04CA4-04+ max 4 aux contacts / 3NC Pos. 3Pos. 2Pos. 1Pos. 4NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30+ max 4 aux contacts / 4NC AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30NFZ31E-30, NFZ22E-30 + max 4 aux contacts / 3NC CA4-04+ max 1 x CAL4-11+ max 1 x CAL4-11Pos. 5Pos. 1 ± 30°+30°-30°AF26Z...38Z-30-11-30AF26Z...38Z-30-11-3035 mm EN/IEC 60715Assembly - Anbau - Montage - MonteringMontaggio - Montaje --22Disassembly - AbbauDémontage - DemonteringSmontaggio - Desmontaje-1LDC4NFZ...-30, AF09Z...38Z-..-30 + LDC4UcA1A2A1A2NFZ...-30,AF09Z...38Z-..-30123UcA1A2NFZ...-30,AF09Z...38Z-..-30A1UcA2TF42AF26Z...38ZCAL4-11AF26Z...38Z-30-11AF26Z...38Z-30-22-30AF09Z...16Z-30-22-30NFZ44E...80E-30TF42AF09Z...38ZAF09Z...16Z-30-01-30AF09Z...16Z-30-10-30AF09Z..16Z-40-00-30AF09Z..16Z-22-00-30NFZ22E ...40E-30CA4 -10 -01CA4-40/22/31/04 CAL4-11 CAL4-11AF09Z ... 38Z-..-..-30AF26Z...38Z-30-00-30Circuit-Breaker XT2V125 + TM60max Fuse30A/RK530A/J5100AF09, AF1210AF16AF09/12/16max Fuse60A/RK5 60A/J5100TF421SBC100330S0201ABB MOTOR PROTECTION AND CONTROL 3/20903
NFZ contactor relays are used for switching auxiliary and control circuits.These contactor relays are of the block type design with:• 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening -can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).•built-in surge suppression •add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuitvoltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)V 50/60 HzV DCkg43NONO4431NCNC3221NCNC2213NONO14A1A2–12...20NFZ22E-201SBH136001R20220.31024...6020...60NFZ22E-211SBH136001R21220.31048...13048...130NFZ22E-221SBH136001R22220.310100...250100...250NFZ22E-231SBH136001R23220.31033NONO3421NCNC2213NONO1443NONO44A1A2–12...20NFZ31E-201SBH136001R20310.31024...6020...60NFZ31E-211SBH136001R21310.31048...13048...130NFZ31E-221SBH136001R22310.310100...250100...250NFZ31E-231SBH136001R23310.31043NONO4433NONO3423NONO2413NONO14A1A2–12...20NFZ40E-201SBH136001R20400.31024...6020...60NFZ40E-211SBH136001R21400.31048...13048...130NFZ40E-221SBH136001R22400.310100...250100...250NFZ40E-231SBH136001R23400.310Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCNFZ22E, NFZ31E, NFZ40E—NFZ 4-pole contactor relaysAC / DC operated for specific applications1SBC101104F0014NFZ22EMain dimensions mm, inches1SBC101559S0201 - Rev. A3/210ABB MOTOR PROTECTION AND CONTROL03
ABB MOTOR PROTECTION AND CONTROL 3/211—NF 4-pole contactor relaysContactor relays and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.Contactor relaytypesMainpolesFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerMechanical latching unitAuxiliary contact blocks2-pole CAL4-11 1-pole CA44-pole CA4TEF4 WA4 (3) Left sideRight sideNF(Z)NF2321E (1)E (1)4 max.or 1or 1or 1+1–2 max.–or 1or 1+1+ 14 0 E (2)NFZ 24 V DC designed for PLC - coil 30NFZ2 2 E (1)4 max.or 1or 1–or1+ 13 1 E (1)2 max.–or 1–+1–4 0 E (2)––1–+1+ 1(1) Including add-on contacts: 3 N.C. auxiliary contacts max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5.(2) Including add-on contacts: 4 N.C. auxiliary contacts max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5.(3) Accept 1-pole CA4 auxiliary contacts (1 block on each side of the mechanical latch) in respect to the total number of additional N.C. auxiliary contacts.For WA4, accessory use with contactor relays coil 30, please consult your ABB local sales organization.NF contactor relayCAL4-112-pole auxiliary contact blockCA41-pole auxiliary contact blockCA44-pole auxiliary contact blockBX4-CAProtective coverBX4-CAProtective coverTEF4Electronic timerBX4Protective coverWA4Mechanical latching unit1SBC101518S0201 - Rev. B03
NF contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with: • 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanicallylinked auxiliary contact elements (side-marked symbol) except for NF33/11 and NF51/11 variants •overlapping of lagging / leading contacts for NF33/11 and NF51/11 variants•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - reduced panel energy consumption - very distinct closing and opening •built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.Number of contactsRated control circuitvoltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)1st stack2nd stackV 50/60 HzV DCkg8-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A224...6020...60(1)NF44E-111SBH137001R11440.32048...13048...130NF44E-121SBH137001R12440.320100...250100...250NF44E-131SBH137001R13440.320250...500250...500NF44E-141SBH137001R14440.36043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A224...6020...60(1)NF53E-111SBH137001R11530.32048...13048...130NF53E-121SBH137001R12530.320100...250100...250NF53E-131SBH137001R13530.320250...500250...500NF53E-141SBH137001R14530.36043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A224...6020...60(1)NF62E-111SBH137001R11620.32048...13048...130NF62E-121SBH137001R12620.320100...250100...250NF62E-131SBH137001R13620.320250...500250...500NF62E-141SBH137001R14620.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A224...6020...60(1)NF71E-111SBH137001R11710.32048...13048...130NF71E-121SBH137001R12710.320100...250100...250NF71E-131SBH137001R13710.320250...500250...500NF71E-141SBH137001R14710.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A224...6020...60(1)NF80E-111SBH137001R11800.32048...13048...130NF80E-121SBH137001R12800.320100...250100...250NF80E-131SBH137001R13800.320250...500250...500NF80E-141SBH137001R14800.3608-pole contactor relays with overlapping of lagging / leading contactsA1A241NCNC4233NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6251NCNC5224...6020...60(1)NF33/11-111SBH137001R11390.32048...13048...130NF33/11-121SBH137001R12390.320100...250100...250NF33/11-131SBH137001R13390.320250...500250...500NF33/11-141SBH137001R14390.320A1A243NONO4433NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6253NONO5424...6020...60(1)NF51/11-111SBH137001R11590.32048...13048...130NF51/11-121SBH137001R12590.320100...250100...250NF51/11-131SBH137001R13590.320250...500250...500NF51/11-141SBH137001R14590.320(1) NF..-11 not suitable for direct control by PLC.—NF 8-pole contactor relaysAC / DC operated35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"NF44E, NF53E, NF62E, NF71E, NF80E, NF33/11, NF51/111SBC101029V0014NF44E1SBC101042V0014NF33/111SBC101043V0014NF51/11Main dimensions mm, inches3/212ABB MOTOR PROTECTION AND CONTROL1SBC101560S0201 - Rev. C03
NFZ contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with:• 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechani-cally linked auxiliary contact elements (side-marked symbol) • control circuit: 24 V DC operated with electronic coil interface allowing low holding consumption up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening• built-in surge suppression.Number of contactsRated control circuitvoltageUcTy pe Order codeWeightPkg(1 pce)V DCkg8-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-24NFZ44E-301SBH136001R30440.49043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-24NFZ53E-301SBH136001R30530.49043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-24NFZ62E-301SBH136001R30620.49043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-24NFZ71E-301SBH136001R30710.49043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-24NFZ80E-301SBH136001R30800.490Note: NFZ contactor relays with DC control voltage 24 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.—NFZ 8-pole contactor relays24 V DC operated designed for PLC1SBC101535V0014NFZ44EMain dimensions mm, inches35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"NFZ44E, NFZ53E, NFZ62E, NFZ71E, NFZ80EContactors AF..Z-...-30, contactor relays NFZ...-30 and accessoriesSchütze AF..Z-...-30, Hilfsschütze NFZ...-30 und ZubehörContacteurs AF..Z-...-30, contacteurs auxiliaires NFZ...-30 et accessoiresKontaktorer AF..Z-...-30, reläkontaktorer NFZ...-30 och tillbehörContattori AF..Z-...-30, contattori ausiliari NFZ...-30 e accessori Contactores AF..Z-...-30, contactores auxiliares NFZ...-30 y accesoriosAF..Z-...-30,NFZ...-30NFZ...-30, 1SBC101053M6801 - 01/18AF09Z...38Z-..-..-30, NFZ22E-30...NFZ80E-30, CA4, CAL4, LDC4Operating instructionsBetriebsanleitungNotice d'instructionInstruktionIstruzioni tecnicheInstrucciones de empleoABB France3, rue Jean Perrin69680 Chassieu / Francewww.abb.com/lowvoltageZ-...-30,35mm EN/EC 607155.5 0.22"91 3.58"97 3.82" 5.5 0.22"10 0.39"35mm EN/EC 607155.5 0.22"91 3.58"130.5 5.14"5.5 0.22"10 0.39"43 1.69"CLIC !4CLIC !2 AmminchNFZ44E...NFZ80E-30 AF09Z...16Z-30-22-30130,5 5.14"AF26Z...38Z-30-22-30AF26Z...38Z-30-11-30139,5 5.49"131,5 5.18" Bmminch91 3.58"100 3.94"100 3.94" Amm inch97 3.82" B mm inch91 3.58"NFZ22E...NFZ40E-30AF09Z...16Z-...-30 AF26Z...38Z-...-30 3-pole106 4.17"100 3.94"45 1,77" 80 3.15" 6 0.24" 2 0.08"2 0.08" AF09Z...38Z-...-30, NFZ22E...NFZ80E-30Acc. to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, min. enclosure for : AF09Z...AF16Z-...-30, NFZ...-30, : 180 x 130 x 175 mmAF26Z...38Z-30-...-30 3-pole : 255 x 180 x 175 mm35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCpozidriv N° 2M 3,51,2 N.mM 3,51,5 N.m2 x1...62 x1...2,5mm²mm²2 x0,75...62 x0,75...2,5 L < 8L < 9,6Ø 5,5Ø 5,5AF09Z...16Z-...-303 & 4-polemm²2 x 0,75...2,51 x 0,75...4AF09Z ... 38Z-...-30NFZ...-30NFZ...-30AF09Z... 38Z-30-22-30AF26Z... 38Z-30-11-30 M 3,51,2 N.mØ 5,5AF26Z...38Z-...-303-poleM 42,5 N.mØ 6,52 x0,75...2,52 x1...2,52 x2,5...102 x1,5...102 x 0,75...1,51 x 0,75... 2,52 x 0,75....1,51 x 0,75... 2,52 x 1,5...41 x 1,5...10L < 12,5 L < 8L < 9,6LLL = 10L = 14L = 10L = 10mmAF09Z...16Z-30-10-30AF09Z...16Z-30-01-30_____LHmmmm-Uc= 24VDCA1A2NFZ...-30AF09Z...38Z-..-30+AF26/AF30/AF38 AF26/AF30/AF38 AF26/AF30/AF38max Fusemax Fuse60A/RK5Circuit BreakerT4V250 + TM250Circuit BreakerXT1H125 + TM100Circuit BreakerXT2V125 + TM10060A/J52535-654265100AF26According to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, for use on a circuit capable of delivering not more than the max. symmetrical amperes at the max. voltage shown in the table below. WARNING : if opening of BCP, controller shall be examined and replaced if damaged.AF30AF38max Fuse100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)480V (kA)600V (kA)Max Short-circuit at100A/RK5 100A/J5100Max Short-circuit at480V, 600V(kA)Max Short-circuit at480V, 600V(kA)NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30NFZ31E-30, NFZ22E-30AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30 + max 4 aux contacts / 2NCCA4-04CA4-04+ max 4 aux contacts / 3NC Pos. 3Pos. 2Pos. 1Pos. 4NFZ40E-30AF09Z...16Z-30-10-30AF09Z...16Z-40-00-30AF26Z...38Z-30-00-30+ max 4 aux contacts / 4NC AF09Z...16Z-30-01-30AF09Z...16Z-22-00-30NFZ31E-30, NFZ22E-30 + max 4 aux contacts / 3NC CA4-04+ max 1 x CAL4-11+ max 1 x CAL4-11Pos. 5Pos. 1 ± 30°+30°-30°AF26Z...38Z-30-11-30AF26Z...38Z-30-11-3035 mm EN/IEC 60715Assembly - Anbau - Montage - MonteringMontaggio - Montaje --22Disassembly - AbbauDémontage - DemonteringSmontaggio - Desmontaje-1LDC4NFZ...-30, AF09Z...38Z-..-30 + LDC4UcA1A2A1A2NFZ...-30,AF09Z...38Z-..-30123UcA1A2NFZ...-30,AF09Z...38Z-..-30A1UcA2TF42AF26Z...38ZCAL4-11AF26Z...38Z-30-11AF26Z...38Z-30-22-30AF09Z...16Z-30-22-30NFZ44E...80E-30TF42AF09Z...38ZAF09Z...16Z-30-01-30AF09Z...16Z-30-10-30AF09Z..16Z-40-00-30AF09Z..16Z-22-00-30NFZ22E ...40E-30CA4 -10 -01CA4-40/22/31/04 CAL4-11 CAL4-11AF09Z ... 38Z-..-..-30AF26Z...38Z-30-00-30Circuit-Breaker XT2V125 + TM60max Fuse30A/RK530A/J5100AF09, AF1210AF16AF09/12/16max Fuse60A/RK5 60A/J5100TF421SBC100431S0201 ABB MOTOR PROTECTION AND CONTROL 3/21303
NFZ contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with: • 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol) except for NFZ33/11 and NFZ51/11 variants•overlapping of lagging / leading contacts for NFZ33/11 and NFZ51/11 variants•control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 coils to cover control voltages between 24 ... 250 V 50/60 Hz and 12 ... 250 V DC -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening -can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request). •built-in surge suppression •add-on auxiliary contact blocks for side mounting and a wide range of accessories.Number of contactsRated control circuitvoltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)1st stack2nd stackV 50/60 HzV DCkg8-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A2-12...20NFZ44E-201SBH136001R20440.36024...6020...60NFZ44E-211SBH136001R21440.36048...13048...130NFZ44E-221SBH136001R22440.360100...250100...250NFZ44E-231SBH136001R23440.36043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A2-12...20NFZ53E-201SBH136001R20530.36024...6020...60NFZ53E-211SBH136001R21530.36048...13048...130NFZ53E-221SBH136001R22530.360100...250100...250NFZ53E-231SBH136001R23530.36043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A2-12...20NFZ62E-201SBH136001R20620.36024...6020...60NFZ62E-211SBH136001R21620.36048...13048...130NFZ62E-221SBH136001R22620.360100...250100...250NFZ62E-231SBH136001R23620.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A2-12...20NFZ71E-201SBH136001R20710.36024...6020...60NFZ71E-211SBH136001R21710.36048...13048...130NFZ71E-221SBH136001R22710.360100...250100...250NFZ71E-231SBH136001R23710.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A2-12...20NFZ80E-201SBH136001R20800.36024...6020...60NFZ80E-211SBH136001R21800.36048...13048...130NFZ80E-221SBH136001R22800.360100...250100...250NFZ80E-231SBH136001R23800.3608-pole contactor relays with overlapping of lagging / leading contactsA1A241NCNC4233NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6251NCNC52-12...20NFZ33/11-201SBH136001R20390.36024...6020...60NFZ33/11-211SBH136001R21390.36048...13048...130NFZ33/11-221SBH136001R22390.360100...250100...250NFZ33/11-231SBH136001R23390.360A1A243NONO4433NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6253NONO54-12...20NFZ51/11-201SBH136001R20590.36024...6020...60NFZ51/11-211SBH136001R21590.36048...13048...130NFZ51/11-221SBH136001R22590.360100...250100...250NFZ51/11-231SBH136001R23590.360Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole—NFZ 8-pole contactor relaysAC / DC operated for specific applications35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"NFZ44E, NFZ53E, NFZ62E, NFZ71E, NFZ80E, NFZ33/11, NFZ51/111SBC101029V0014NFZ44E1SBC101042V0014NFZ33/111SBC101043V0014NFZ51/11Main dimensions mm, inches3/214ABB MOTOR PROTECTION AND CONTROL1SBC101561S0201 - Rev. B03
1SBC101598S0201 - Rev. DABB MOTOR PROTECTION AND CONTROL 3/215BX4-CAProtective cover—NF 8-pole contactor relaysContactor relays and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesContactor relaytypesMainpolesSide-mounted accessoriesAuxiliary contact blocks2-pole CAL4-11 (1) Left sideRight sideNF45678354321031EEEEE//11111–(1) not allowed for 24 V DC operated contactor relay (coil 30).NF contactor relayCAL4-112-pole auxiliary contact block03
—NF contactor relaysTechnical dataContact utilization characteristics according to IECContactor relay typesAC / DC operatedNFStandardsIEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ith θ ≤ 40 °C16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz6 A220-240 V 50/60 Hz4 A400-440 V 50/60 Hz3 A500 V 50/60 Hz2 A690 V 50/60 Hz2 ARated making capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Rated breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC0.27 A / 60 W250 V DC0.27 A / 68 W400 V DC0.15 A / 60 W500 V DC0.13 A / 65 W600 V DC0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s100 Afor 0.1 s140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts≥ 2 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4 aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Contact utilization characteristics according to UL / CSAContactor relay typesAC / DC operatedNFStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA3/216ABB MOTOR PROTECTION AND CONTROL1SBC101562S0201 - Rev. A03
—NF contactor relaysTechnical dataMagnet System Characteristics - NF contactor relays AC / DC operatedContactor relay typesAC / DC operatedNFCoil operating limitsAC supplyAt θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.acc. to IEC 60947-5-1At θ ≤ 70 °C 0.85 x Uc min...Uc max.DC supplyat θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc maxat θ ≤ 70 °C 0.85 x Uc min ... Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24...500 V ACCoil consumptionAverage pull-in value50 VA Average holding value2.2 VA / 2 WDC control voltageRated control circuit voltage Uc20...500 V DCCoil consumptionAverage pull-in value50 WAverage holding value2 W PLC-output controlNot suitable for direct control by PLC-outputDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706–Dips withstand-20 °C ≤ θ ≤ +60 °C–Operating timeBetween coil energization and:N.O. contact closing40...95 msN.C. contact opening38...90 msBetween coil de-energization and:N.O. contact opening11...95 msN.C. contact closing13...98 msMagnet System Characteristics - NFZ contactor relays 24V DC operated - designed for PLC - coil 30Contactor relay typesDC operatedNFZCoil operating limitsDC supplyat θ ≤ 60 °C 0.85 ... 1.1x Ucat θ ≤ 70 °C Ucacc. to IEC 60947-5-1DC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull-in value6 WAverage holding value1.7 W PLC-output control ≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detection Drop-out voltage≤ 60 % of Uc min.Operating timeBetween coil energization and:N.O. contact closing27 ... 53 msN.C. contact opening20 ... 35 msBetween coil de-energization and:N.O. contact opening17 ... 29 msN.C. contact closing22 ... 57 msMagnet System Characteristics - NFZ... contactor relays - for specific applications - coils 20, 21, 22, 23Contactor relay typesAC / DC operatedNFZCoil operating limitsAC supplyat θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc maxat θ ≤ 70 °C 0.85 x Uc min ... Uc maxacc. to IEC 60947-5-1DC supplyat θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24...250 V ACCoil consumptionAverage pull-in value16 VA Average holding value1.7 VA / 1.5 WDC control voltageRated control circuit voltage Uc12...250 V DCCoil consumptionAverage pull-in value12 ... 16 WAverage holding value1.7 WPLC-output control(NFZ coil 21) ≥ 500 mA 24 V DC for PLCs - Not suitable for safety PLCsDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity acc. to SEMI F47-0706Conditions of use on requestDips withstand-20 °C ≤ θ ≤ +60 °C(NFZ coil 21, 22, 23) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DCOperating timeBetween coil energization and:N.O. contact closing40...95 msN.C. contact opening38...90 msBetween coil de-energization and:N.O. contact opening11...95 msN.C. contact closing13...98 ms ABB MOTOR PROTECTION AND CONTROL 3/2171SBC101563S0201 - Rev. C03
—NF contactor relaysTechnical dataGeneral technical dataContactor relay typesAC / DC operatedNFRated insulation voltage Uiacc. to IEC 60947-5-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactor relayOperation in free air-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles20 millions operating cyclesMax. switching frequency6000 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1B2AAB1C2C1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionA30 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstand5...300 Hzacc. to IEC 60068-2-64 g closed position / 2 g open position(1) Environment B: all NF contactor relays produced since week 08-2013. NF..E-12 (48...130 V 50/60 Hz-DC) compliant to environment A only: for environment B, select NFZ..E-22.Mounting characteristicsContactor relay typesAC / DC operatedNFMounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.C. auxiliary contacts:see accessory fitting details for a NF contactor relayMounting distancesThe contactor relays can be assembled side by side.FixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonallyConnecting characteristicsContactor relay typesAC / DC operatedNFMain terminalsScrew terminals with cable clampConnection capacity (min. ... max.)Pole and coil terminalsRigid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torquePole terminals1.2 Nm / 11 lb.inCoil terminals1.2 Nm / 11 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529All terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 23/218ABB MOTOR PROTECTION AND CONTROL1SBC101564S0201 - Rev. B03
ABB MOTOR PROTECTION AND CONTROL 3/2191SBC100439S0201—NF..K contactor relays - with Push-in Spring terminalsAC / DC operated NF22EK1SBC101568V00141SBC101570V0014NF44EK45 1.77"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" NF22EK, NF31EK, NF40EK 45 1.77"82 3.22"10.5 0.41"71 2.79"110.5 4.35"5.5 0.22"5.5 0.22"35mm EN/EC 6071510 0.39"45 1.77"NF44EK, NF53EK, NF62EK, NF71EK, NF80EKMain dimensions mm, inchesNF..K contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with:• 4 poles and 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - reduced panel energy consumption - very distinct closing and opening• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuit voltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)V 50/60 HzV DCkg4-pole contactor relays43NONO4431NCNC3221NCNC2213NONO14A1A224 ... 60 20 ... 60(1) NF22EK-111SBH137005R11220.28548 ... 130 48 ... 130NF22EK-121SBH137005R12220.285100 ... 250 100 ... 250NF22EK-131SBH137005R13220.285250 ... 500 250 ... 500NF22EK-141SBH137005R14220.32533NONO3421NCNC2213NONO1443NONO44A1A224 ... 60 20 ... 60(1) NF31EK-111SBH137005R11310.28548 ... 130 48 ... 130NF31EK-121SBH137005R12310.285100 ... 250 100 ... 250NF31EK-131SBH137005R13310.285250 ... 500 250 ... 500NF31EK-141SBH137005R14310.32543NONO4433NONO3423NONO2413NONO14A1A224 ... 60 20 ... 60(1) NF40EK-111SBH137005R11400.28548 ... 130 48 ... 130NF40EK-121SBH137005R12400.285100 ... 250 100 ... 250NF40EK-131SBH137005R13400.285250 ... 500 250 ... 500NF40EK-141SBH137005R14400.3258-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A224 ... 60 20 ... 60(1) NF44EK-111SBH137005R11440.33048 ... 130 48 ... 130NF44EK-121SBH137005R12440.330100 ... 250 100 ... 250NF44EK-131SBH137005R13440.330250 ... 500 250 ... 500NF44EK-141SBH137005R14440.37043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A224 ... 60 20 ... 60(1) NF53EK-111SBH137005R11530.33048 ... 130 48 ... 130NF53EK-121SBH137005R12530.330100 ... 250 100 ... 250NF53EK-131SBH137005R13530.330250 ... 500 250 ... 500NF53EK-141SBH137005R14530.37043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A224 ... 60 20 ... 60(1) NF62EK-111SBH137005R11620.33048 ... 130 48 ... 130NF62EK-121SBH137005R12620.330100 ... 250 100 ... 250NF62EK-131SBH137005R13620.330250 ... 500 250 ... 500NF62EK-141SBH137005R14620.37043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A224 ... 60 20 ... 60(1) NF71EK-111SBH137005R11710.33048 ... 130 48 ... 130NF71EK-121SBH137005R12710.330100 ... 250 100 ... 250NF71EK-131SBH137005R13710.330250 ... 500 250 ... 500NF71EK-141SBH137005R14710.37043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A224 ... 60 20 ... 60(1) NF80EK-111SBH137005R11800.33048 ... 130 48 ... 130NF80EK-121SBH137005R12800.330100 ... 250 100 ... 250NF80EK-131SBH137005R13800.330250 ... 500 250 ... 500NF80EK-141SBH137005R14800.370(1) NF..K-11 not suitable for direct control by PLC-output.03
3/220ABB MOTOR PROTECTION AND CONTROL1SBC100500S0201—NFZ..K contactor relays - with Push-in Spring terminals24 V DC operated designed for PLCNFZ22EK-30NFZ44EK-3045 1.77"82 3.22"10.5 0.41"91 3.58"97 3.82"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" NFZ22EK, NFZ31EK, NFZ40EK45 1.77"82 3.22"10.5 0.41"35mm EN/EC 607155.5 0.22"91 3.58"130.5 5.14"5.5 0.22"10 0.39"45 1.77"NFZ44EK, NFZ53EK, NFZ62EK, NFZ71EK, NFZ80EKMain dimensions mm, inchesNFZ contactor relays are used for switching auxiliary and control circuits.These contactor relays are of the block type design with 4 poles or 8 poles (with a permanently fixed 4-pole auxiliary contact block). •contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)•control circuit: 24 V DC operated with electronic coil interface allowing low holding consumption up to 1.7 W and reduced panel energy consumption -allow direct control by PLC-output ≥ 250 mA 24 V DC - very distinct closing and opening•built-in surge suppression•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuit voltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)V DCkg4-pole contactor relays43NONO4431NCNC3221NCNC2213NONO14A1+A2-24NFZ22EK-301SBH136005R30220.43533NONO3421NCNC2213NONO1443NONO44A1+A2-24NFZ31EK-301SBH136005R30310.43543NONO4433NONO3423NONO2413NONO14A1+A2-24NFZ40EK-301SBH136005R30400.4358-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-24NFZ44EK-301SBH136005R30440.49043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-24NFZ53EK-301SBH136005R30530.49043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-24NFZ62EK-301SBH136005R30620.49043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-24NFZ71EK-301SBH136005R30710.49043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-24NFZ80EK-301SBH136005R30800.490Note: NFZ contactor relays with 24 V DC control voltage need to respect the connection polarities indicated close to the coilterminals: A1+ for the positive pole and A2- for the negative pole.For product availability, please consult your ABB local sales organization.1SBC101649V00141SBC101651V001403
ABB MOTOR PROTECTION AND CONTROL 3/2211SBC100440S0201—NFZ..K contactor relays - with Push-in Spring terminalsAC / DC operated for specific applications NFZ22EK1SBC101568V001445 1.77"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22" NFZ22EK, NFZ31EK, NFZ40EKMain dimensions mm, inchesNFZ..K contactor relays are used for switching auxiliary and control circuits. These contactor relays are of the block type design with:• 4 poles and 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)• control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC) - can manage large control voltage variations - only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC -allow direct control by PLC-output ≥ 24 V DC 500 mA - reduced panel energy consumption - very distinct closing and opening -c an withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.Number of contactsRated control circuit voltageUc min. ... Uc max.Ty pe Order codeWeightPkg(1 pce)V 50/60 HzV DCkg4-pole contactor relays43NONO4431NCNC3221NCNC2213NONO14A1A2–12 ... 20NFZ22EK-201SBH136005R20220.31524 ... 60 20 ... 60NFZ22EK-211SBH136005R21220.31548 ... 130 48 ... 130NFZ22EK-221SBH136005R22220.315100 ... 250 100 ... 250NFZ22EK-231SBH136005R23220.31533NONO3421NCNC2213NONO1443NONO44A1A2–12 ... 20NFZ31EK-201SBH136005R20310.31524 ... 60 20 ... 60NFZ31EK-211SBH136005R21310.31548 ... 130 48 ... 130NFZ31EK-221SBH136005R22310.315100 ... 250 100 ... 250NFZ31EK-231SBH136005R23310.31543NONO4433NONO3423NONO2413NONO14A1A2–12 ... 20NFZ40EK-201SBH136005R20400.31524 ... 60 20 ... 60NFZ40EK-211SBH136005R21400.31548 ... 130 48 ... 130NFZ40EK-221SBH136005R22400.315100 ... 250 100 ... 250NFZ40EK-231SBH136005R23400.3158-pole contactor relays43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A2–12 ... 20NFZ44EK-201SBH136005R20440.36024 ... 60 20 ... 60NFZ44EK-211SBH136005R21440.36048 ... 130 48 ... 130NFZ44EK-221SBH136005R22440.360100 ... 250 100 ... 250NFZ44EK-231SBH136005R23440.36043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A2–12 ... 20NFZ53EK-201SBH136005R20530.36024 ... 60 20 ... 60NFZ53EK-211SBH136005R21530.36048 ... 130 48 ... 130NFZ53EK-221SBH136005R22530.360100 ... 250 100 ... 250NFZ53EK-231SBH136005R23530.36043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A2–12 ... 20NFZ62EK-201SBH136005R20620.36024 ... 60 20 ... 60NFZ62EK-211SBH136005R21620.36048 ... 130 48 ... 130NFZ62EK-221SBH136005R22620.360100 ... 250 100 ... 250NFZ62EK-231SBH136005R23620.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A2–12 ... 20NFZ71EK-201SBH136005R20710.36024 ... 60 20 ... 60NFZ71EK-211SBH136005R21710.36048 ... 130 48 ... 130NFZ71EK-221SBH136005R22710.360100 ... 250 100 ... 250NFZ71EK-231SBH136005R23710.36043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A2–12 ... 20NFZ80EK-201SBH136005R20800.36024 ... 60 20 ... 60NFZ80EK-211SBH136005R21800.36048 ... 130 48 ... 130NFZ80EK-221SBH136005R22800.360100 ... 250 100 ... 250NFZ80EK-231SBH136005R23800.360Note: NFZ contactor relays with 12...20 V DC control voltage need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.1SBC101570V0014NFZ44EK 45 1.77"82 3.22"10.5 0.41"71 2.79"110.5 4.35"5.5 0.22"5.5 0.22"35mm EN/EC 6071510 0.39"45 1.77"NFZ44EK, NFZ53EK, NFZ62EK, NFZ71EK, NFZ80EK03
—NF..K contactor relays - with Push-in Spring terminalsContactor relays and main accessoriesMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.Contactor relaytypesMain polesFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerAuxiliary contact blocks2-pole CAL4-11K1-pole CA4..K4-pole CA4..KTEF4SLeft sideRight sideNF(Z)NF2 2 EK (1)4 max.or 1or 1+ 1-3 1 EK (1)2 max.-or 1+ 1+ 14 0 EK (2)NF4 4EK----+ 1-5 3EK6 2EK7 1EK8 0EKNFZ 24 V DC designed for PLC - coil 30NFZ2 2 EK (1)4 max.or 1or 1or1+ 13 1 EK (1)2 max.-or 1+14 0 EK (2) 1+ 1+ 1NFZ4 4EK-----5 3EK6 2EK7 1EK8 0EK(1 ) Including add-on contacts: 3 N.C. max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5(2) Including add-on contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5CAL4-11K2-pole auxiliarycontact blockCA4..K4-poleauxiliary contact blockTEF4SElectronic timerCA4..K1-pole auxiliarycontact blockNF.. K contactor relayCAL4-11K2-pole auxiliarycontact blockBX4-CAProtective coverBX4-CAProtective coverNF.. K contactor relayBX4protective cover3/222ABB MOTOR PROTECTION AND CONTROL1SBC100413S0201 - Rev. A03
ABB MOTOR PROTECTION AND CONTROL 3/2231SBC100441S0201Contact utilization characteristics according to IECContactor relay typesAC / DC operatedNF.. KStandardsIEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free air thermal current Ith - θ ≤ 40 °C 16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 W400 V DC 0.15 A / 60 W500 V DC 0.13 A / 65 W600 V DC 0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Afor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts≥ 2 msPower dissipation per pole at 6 A0.1 WMaximum electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsacc. to annex L of IEC 60947-5-1Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4 aux. contact blocks) are mechanically linked contactsContact utilization characteristics according to UL / CSAContactor relay typesNF.. KStandardsUL 508, CSA C22.2 N°14Maximum operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—NF..K contactor relays - with Push-in Spring terminalsTechnical data03
3/224ABB MOTOR PROTECTION AND CONTROL1SBC100442S0201 - Rev. A—NF..K contactor relays - with Push-in Spring terminalsTechnical dataGeneral technical dataContactor relay typesAC / DC operatedNF.. KRated insulation voltage Uiacc. to IEC 60947-5-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVElectromagnetic compatibilityDevices complying with IEC 60947-1 / EN 60947-1 - Environment A and B (1)Ambient air temperature close to contactor relayOperation in free air-40 ... +70 °CStorage-60 ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles20 million operating cyclesMaximum switching frequency6000 cycles/hShock withstandacc. to IEC 60068-2-27 and EN 60068-2-27Mounting position 1Shock direction1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionB2AAB1C2C1A30 gB1 25 g closed position / 5 g open positionB2 15 gC1 25 gC2 25 gVibration withstandacc. to IEC 60068-2-65 ... 300 Hz 4 g closed position / 2 g open position(1) NF..-12 (48...130 V 50/60 Hz-DC) compliant to environment A only. For environment B: select NFZ..-22.Mounting characteristics Contactor relay typesAC / DC operatedNF.. KMounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Max. add-on N.C. auxiliary contacts: see accessory fitting details for a NF contactor relayMounting distancesThe contactor relays can be assembled side by sideFixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonallyConnecting characteristicsContactor relay typesAC / DC operatedNF.. KMain terminalsPush-in Spring terminalsConnection capacity (min. ... max.)Pole and coil terminalsRigid1 x 1 ... 2.5 mm²2 x 1 ... 2.5 mm²Flexible with non insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²Flexible with insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²Flexible without ferrule1 x (spring) 0.5 ... 2.5 mm²2 x (spring) 0.5 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 18 ... 14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1and IEC 60529 / EN 60529IP20Screwdriver typeAll terminalsFlat Ø 3 mm x 0.5 mm03
ABB MOTOR PROTECTION AND CONTROL 3/2251SBC100501S0201 - Rev. A—NF..K contactor relays - with Push-in Spring terminalsTechnical dataMagnet System Characteristics for NF..K contactor relays - AC / DC operatedContactor relay typesAC / DC operatedNF.. KCoil operating limits acc. to IEC 60947-5-1AC supplyat θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc maxat θ ≤ 70 °C 0.85 x Uc min ... Uc maxDC supplyAt θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max At θ ≤ 70 °C 0.85 x Uc min ... Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 500 V ACCoil consumptionAverage pull-in value50 VAAverage holding value2.2 VA / 2 W DC control voltageRated control circuit voltage Uc20 ... 500 V DCCoil consumptionAverage pull-in value50 W Average holding value2 WPLC-output controlNot suitable for direct control by PLC-outputDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity according to SEMI F47-0706–Dips withstand -20 °C ≤ θ ≤ +60°C–Operating timeBetween coil energization and:N.O. contact closing40 ... 95 msN.C. contact opening38 ... 90 msBetween coil de-energization and:N.O. contact opening11 ... 95 msN.C. contact closing13 ... 98 msMagnet System Characteristics for NFZ..K contactor relays 24V DC operated - designed for PLC - coil 30Contactor relay typesAC / DC operatedNFZ..KCoil operating limits acc. to IEC 60947-5-1DC supplyAt θ ≤ 60 °C 0.85 ... 1.1 x UcAt θ ≤ 70 °C UcDC control voltageRated control circuit voltage Uc24 V DCCoil consumptionAverage pull-in value6 WAverage holding value1.7 WPLC-output control≥ 250 mA 24 V DC for PLCs and safety PLCs using broken wire detectionDrop-out voltage≤ 60 % of Uc min.Operating timeBetween coil energization and:N.O. contact closing27 ... 53 msN.C. contact opening20 ... 35 msBetween coil de-energization and:N.O. contact opening17 ... 29 msN.C. contact closing22 ... 57 msMagnet System Characteristics for NFZ..K contactor relays - for specific applications - coils 20, 21, 22, 23Contactor relay typesAC / DC operatedNFZ..KCoil operating limits acc. to IEC 60947-5-1AC supplyAt θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc maxAt θ ≤ 70 °C 0.85 x Uc min ... Uc maxDC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 250 V ACCoil consumptionAverage pull-in value16 VAAverage holding value1.7 VA / 1.5 WDC control voltageRated control circuit voltage Uc12 ... 250 V DCCoil consumptionAverage pull-in value12 ... 16 WAverage holding value1.7 WPLC-output control(AF..Z coil 21) ≥ 500 mA 24 V DC for PLCsDrop-out voltage≤ 60 % of Uc min.Voltage sag immunity according to SEMI F47-0706 (NFZ coil 21, 22, 23) conditions of use on requestDips withstand -20 °C ≤ θ ≤ +60°C(NFZ coil 21, 22, 23) 20 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DCOperating timeBetween coil energization and:N.O. contact closing40 ... 95 msN.C. contact opening38 ... 90 msBetween coil de-energization and:N.O. contact opening11 ... 95 msN.C. contact closing13 ... 98 ms03
— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310
—AccessoriesAccessories for AF09 ... AF2850 3-pole contactors, AF09 ... AF370 4-pole contactors and NF contactor relays 3/230 Auxiliary contact blocks 3/245 Electronic timers 3/248 Interlocks3/250 Impulse contact blocks3/252 Interface relays3/254 Mechanical latching units3/256 Other accessories3/258 Additional terminal blocks3/259 Terminal shrouds3/260 Connections3/261 Terminal connecting strips and shorting bars3/262 Connection accessories for starting solutions3/263 Connection sets for star-delta starter3/264 Connection accessories for starting solutions with Push-in Spring terminals3/265 Connection bars3/266 Mounting plates3/267 Adapter plates3/268 Low Voltage Ride Through (LVRT) modules 3/269 Contactor coils, main contact sets and arc chutesAccessories for UA, UA..RA, GA75, GAE75, GAF contactors 3/272 Auxiliary contact blocks3/278 Electronic timers3/282 Mechanical and electrical interlock units3/284 CA5, CE5, CAL, CEL18 and TEF5 fitting details3/285 Function markers - Mounting piece3/286 Surge suppressors for contactor coils3/288 Interface relays3/290 Mechanical latching units3/292 Additional terminal blocks and others accessories3/293 Terminals for control lead connections3/294 Connection bar for contactors3/295 Contactor coils and main contact setsAccessories for EK550, EK1000 4-pole contactors3/298 Auxiliary contact blocks3/302 Mechanical interlock units, terminal shrouds and connection sets3/303 Surge suppressors for contactor coils3/305 Main contact sets - Arc chutes3/306 Contactor coils3/404 Voltage code tableABB MOTOR PROTECTION AND CONTROL 3/227
—Accessories for AF09 ... AF2850 3-pole contactors, AF09 ... AF370 4-pole contactors and NF contactor relays3/230 Auxiliary contact blocks 3/245 Electronic timers 3/248 Interlocks3/250 Impulse contact blocks3/252 Interface relays3/254 Mechanical latching units3/256 Other accessories3/258 Additional terminal blocks3/259 Terminal shrouds3/260 Connections3/261 Terminal connecting strips and shorting bars3/262 Connection accessories for starting solutions3/263 Connection sets for star-delta starter3/264 Connection accessories for starting solutions with Push-in Spring terminals3/265 Connection bars3/266 Mounting plates3/267 Adapter plates3/268 Low Voltage Ride Through (LVRT) modules 3/269 Contactor coils, main contact sets and arc chutesABB MOTOR PROTECTION AND CONTROL 3/22903— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310
—Auxiliary contact blocks for AF09 ... AF96 contactors and NF contactor relaysThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:•CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts•CC4 1-pole block, with N.O. leading contact or N.C. lagging contact•CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connec-tion on front face.Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Termi-nal marking and positioning").Types of auxiliary contact blocks for side mounting:•CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce)kgFront-mounted instantaneous auxiliary contact blocksAF09 ... AF964-pole NF1 0– –CA4-101SBN010110R101010.0141 0– –CA4-10-T1SBN010110T1010100.0140 1– –CA4-011SBN010110R100110.0140 1– –CA4-01-T1SBN010110T1001100.014AF09 ... AF16..-30-102 2– –CA4-22M1SBN010140R112210.0553 1– –CA4-31M1SBN010140R113110.0551 3– –CA4-13M1SBN010140R111310.0550 4– –CA4-04M1SBN010140R110410.055AF26 ... AF96..-30-00AF09 ... AF80..-40-00AF09 ... AF80..-22-002 2– –CA4-22E1SBN010140R102210.0553 1– –CA4-31E1SBN010140R103110.0554 0– –CA4-40E1SBN010140R104010.055AF26 ... AF96..-30-00AF09 ... AF16..-40-00AF40 ... AF80..-40-000 4– –CA4-04E1SBN010140R100410.055AF09 ... AF16..-30-012 2– –CA4-22U1SBN010140R132210.0553 1– –CA4-31U1SBN010140R133110.0554 0– –CA4-40U1SBN010140R134010.0554-pole NF2 2– –CA4-22N1SBN010140R122210.0553 1– –CA4-31N1SBN010140R123110.0554 0– –CA4-40N1SBN010140R124010.0551 3– –CA4-13N1SBN010140R121310.055NF..40E0 4– –CA4-04N1SBN010140R120410.055Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contactAF09 ... AF964-pole NF– –1 0CC4-101SBN010111R101010.014– –0 1CC4-011SBN010111R100110.014Note: 1 max CC4-10 and 1 max CC4-01. CC4-01 use: on each "Accessory fitting details" table, the allowed number of N.C. add-on and built-in contacts including CC4-01, is decreased by one.Side-mounted instantaneous auxiliary contact blocksAF09 ... AF96NF1 1– –CAL4-111SBN010120R101110.0401 1– –CAL4-11-T1SBN010120T1011100.040Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocksAF09 ... AF16..-30-101 1– –CAT4-11M1SBN010151R111110.040AF26 ... AF65..-30-00AF09 ... AF52..-40-00AF09 ... AF40..-22-001 1– –CAT4-11E1SBN010151R101110.040AF09 ... AF16..-30-011 1– –CAT4-11U1SBN010151R131110.040For each contactor or contactor relay type, refer to "Accessory fitting details" table.Note: CAT4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC (coil 20) and 24 V DC (coil 30).3/230ABB MOTOR PROTECTION AND CONTROL1SBC101573S0201 - Rev. A03CAL4-111SBC100007V0014CA4-101SBC100001V0014C AT4 -1 1E1SBC100002V0014CA4-22E1SBC100006V0014
1SBC101593S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/231—Auxiliary contact blocks for AF09 ... AF96 contactors and NF contactor relaysTechnical dataContact utilization characteristics according to IECTy pes1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4StandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp.6 kVRated operational voltage Ue max.24...690 VConventional thermal current Ith - θ ≤ 40 °C16 ARated frequency (without derating)50/60 HzIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 W400 V DC 0.15 A / 60 W500 V DC 0.13 A / 65 W600 V DC 0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Power dissipation per pole at 6 A0.1 WMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contacts acc. to annex L of IEC 60947-5-1Additional N.O. or N.C. auxiliary contacts (CA4, CAL4, CAT4) are mechanically linked contactsMirror contacts acc. to annex F of IEC 60947-4-1Additional N.C. auxiliary contacts (CA4, CAL4, CAT4) are mirror contactsContact utilization characteristics according to UL / CSATy pes1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4StandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VAConnecting characteristicsTy pes1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4Connection capacity (min. ... max.)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torque1.2 Nm / 11 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
3/232ABB MOTOR PROTECTION AND CONTROL1SBC100417S0201—Auxiliary contact blocks with Push-in Spring terminalsThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments. Types of auxiliary contact blocks for front mounting:•CA4..K 1 or 4-pole block, with instantaneous N.O., N.C. contactsSelect the 4-pole auxiliary contact blocks CA4-..EK, CA4-..MK or CA4-..NK type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning").Types of auxiliary contact blocks for side mounting:•CAL4..K 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors.The auxiliary contact blocks are equipped with push-in spring terminals protected against acci-dental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce)kgFront-mounted instantaneous auxiliary contact blocksAF09 ... AF96NF1 0CA4-10K1SBN010160R101010.0121 0CA4-10K-T1SBN010160T1010100.0120 1CA4-01K1SBN010160R100110.0120 1CA4-01K-T1SBN010160T1001100.012AF09 ... AF16..-30-102 2CA4-22MK1SBN010146R112210.0503 1CA4-31MK1SBN010146R113110.0501 3CA4-13MK1SBN010146R111310.0500 4CA4-04MK1SBN010146R110410.050AF26 ... AF96..-30-00AF09 ... AF80..-40-00AF09 ... AF80..-22-002 2CA4-22EK1SBN010146R102210.0503 1CA4-31EK1SBN010146R103110.0504 0CA4-40EK1SBN010146R104010.0504-pole NF1 3CA4-13NK1SBN010146R121310.0502 2CA4-22NK1SBN010146R122210.0503 1CA4-31NK1SBN010146R123110.0504 0CA4-40NK1SBN010146R124010.050NF40E0 4CA4-04NK1SBN010146R120410.050Side-mounted instantaneous auxiliary contact blocks3-poleAF09 ... AF96 NF1 1CAL4-11K1SBN010134R101110.030Note: for each contactor or contactor relay type, refer to "Accessory fitting details" table.CA4-10K1SBC100080V0014CAL4-11K1SBC100082V0014CA4-22EK1SBC100081V001403
1SBC100447S0201 ABB MOTOR PROTECTION AND CONTROL 3/233Contact utilization characteristics according to IECContactor relay types1-pole CA4..K, 4-pole CA4..K, 2-pole CAL4..KStandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp.6 kVRated operational voltage Ue max.690 VConventional thermal current Ith - θ ≤ 40 °C16 ARated frequency (without derating)50 / 60 HzIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 W400 V DC 0.15 A / 60 W500 V DC 0.13 A / 65 W600 V DC 0.1 A / 60 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacitywith failure rate acc. to IEC 60947-5-412 V / 3 mA10-7Power dissipation per pole at 6 A0.1 WMechanical durabilityNumber of operating cycles10 million operating cyclesMax. switching frequency3600 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contacts acc. to annex L of IEC 60947-5-1Additional N.O. or N.C. auxiliary contacts (CA4, CAL4) are mechanically linked contacts.Mirror contacts acc. to annex F of IEC 60947-4-1Additional N.C. auxiliary contacts (CA4, CAL4) are mirror contacts.Contact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22 N°14Max. operational voltage600 V AC, 600 V DCPilot dutyA600, Q600AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VAConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1 ... 2.5 mm²2 x 1 ... 2.5 mm²Flexible with ferrule1 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 2.5 mm²Flexible with insulated ferrule1 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²2 x 1 (push-in) / 0.5 (spring) ... 1.5 mm²Flexible without ferrule1 x (spring) 0.5 ... 2.5 mm²2 x (spring) 0.5 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 18 ... 14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screwdriver typeFlat Ø 3 mm x 0.5 mm—Auxiliary contact blocks for AF09 ... AF96 contactors and NF contactor relays with Push-in Spring terminalsTechnical data03
1SBC101905S0201 - Rev. A3/234ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for severe industrial environmentsfor AF09 ... AF96 contactors and NF contactor relaysThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for severe industrial environments.Types of auxiliary contact blocks for front mounting:•CE5 1-pole block, instantaneous with N.O. contact or N.C. contact, available in 2 IP degrees - CE5 D with built-in microswitch IP40, degree of protection (IP20 on terminals) - CE5 W with built-in microswitch IP67, degree of protection (IP20 on terminals).The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgAF09 ... AF96NF1–– –CE5-10D0.11SBN010015R101010.020–1– –CE5-01D0.11SBN010015R100110.0201–– –CE5-10D21SBN010017R101010.020–1– –CE5-01D21SBN010017R100110.0201–– –CE5-10W0.11SBN010016R101010.020–1– –CE5-01W0.11SBN010016R100110.0201–– –CE5-10W21SBN010018R101010.020–1– –CE5-01W21SBN010018R100110.020(1) For each contactor type, refer to "Accessory fitting details" table.Note: For use with 24 V DC operated AF..Z contactor and NFZ contactor relay (coil 30), please consult your ABB local sales organization.1SBC101030V0014CE5-10WA47 1.85"1-pole CE5 onAAF09 ... AF16..-30-xx 1 stackAF09, AF16..-40/22-00NF..E 1-stack103.5 mm / 4.07"AF26 ... AF38..-30-00112.5 mm / 4.43"AF26, AF38..-40/22-00127.5 mm / 5.02"AF40 ... AF65-30-00137 mm / 5.39"AF40 ... AF65-40/22-00140 mm / 5.51"AF80 ... AF96-30-00142 mm / 5.59"AF80-40/22-00142 mm / 5.59"Main dimensions mm, inches03
1SBC101906S0201 ABB MOTOR PROTECTION AND CONTROL 3/235—Auxiliary contact blocks for severe industrial environmentsTechnical dataFront mountedTy pes1-pole CE5-..0.11-pole CE5-..2Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Uiacc. to IEC 60947-5-1250 VRated operational voltage Ue max.125 V250 VConventional thermal current Ith - θ ≤ 40 °C0.1 A2 ARated frequency (without derating)50 / 60 HzIe / Rated operational currentAC-14AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 0.1 A2 A220-240 V 50/60 Hz–2 AMaking capacity6 x Ie AC-14 acc. to IEC 60947-5-110 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity6 x Ie AC-14 acc. to IEC 60947-5-110 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-12acc. to IEC 60947-5-124 V DC 0.1 A2 A48 V DC 0.1 A1 A72 V DC 0.1 A0.3 A110 V DC 0.1 A0.2 A125 V DC–0.2 A220 V DC–0.1 AShort-circuit protection device FF type fuse (1)0.1 A10 AMinimum switching capacityAF09 ... AF38 contactors3 V / 1 mA17 V / 1 mAwith failure rate acc. to IEC 60947-5-4–≤ 10-7Mechanical durabilityNumber of operating cycles5 millions for CE5-..D0.15 millions for CE5-..D22.5 millions for CE5-..W0.12.5 millions for CE5-..W2Max. switching frequency3600 cycles/hElectrical durabilityNumber of operating cycles2.5 millions for CE5-..D0.11 million for CE5-..D20.7 millions for CE5-..W0.10.3 millions for CE5-..W2Max. electrical switching frequencyAC-141200 cycles/hAC-151200 cycles/hDC-12900 cycles/hContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage125 V AC / 110 V DC250 V AC / 220 V DCPilot dutyAC thermal rated current0.1 A2 AConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 7.7 mml >3.7 mmConnecting capacity acc. to UL / CSA1 or 2 x AWG 18...14Tightening torque1 NmDegree of protectionTerminalsIP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529MicroswitchesIP40 for CE5-..D0.1IP40 for CE5-..D2IP67 for CE5-..W0.1IP67 for CE5-..W2Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2(1) HRC fuses for very fast action (6.3 x 32 mm size).03
1SBC101907S0201 - Rev. A3/236ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for severe industrial environmentsFor AF09 ... AF96 3-pole contactors and AF09 ... AF80 4-pole contactorsFor AF contactorsMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMainpolesBuilt-inauxiliarycontactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectrical and mechanical interlock setAuxiliary contact blocks(Between 2 contactors)Left sideRight side1-pole CE51-pole CA4VEM42-pole CAL4-113-pole contactors AF09 ... AF96Max. N.C. built-in and add-on N.C. auxiliary contacts (CA4, CAL4, VEM4):2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4AF09 ... AF163 0 0 11+ 3 max.–+1–AF09 ... AF163 0 1 02+ 2 max.–––AF26 ... AF383 0 0 01+ 3 max.–+1–1+ 1 max.–+1+ 11+ 2 max.+ 1+1–Max. N.C. built-in or add-on N.C. auxiliary contacts (CA4, CAL4, VEM4):1 max. with 1 CE5 on positions 1 ±30°, 5AF09 ... AF163 0 0 11+ 3 max.–––AF09 ... AF163 0 1 01+ 3 max.–+ 1–AF26 ... AF383 0 0 01+ 2 max.+ 1––Max. add-on N.C. auxiliary contacts (CA4, CAL4):4 max. with 1 CE5, 2 max. with 2 CE5 on positions 1, 1 ±30°, 2, 3, 4, 5AF40 ... AF963 0 0 02+ 2 max.–+1+ 11+ 3 max.–+ 1+ 14-pole contactors AF09 ... AF80Max. add-on N.C. auxiliary contacts (CA4, CAL4, VEM4):2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4AF09, AF164 0 0 02+ 2 max.–––1+ 3 max.–+1–1+ 1 max.–+1+ 11+ 2 max.+ 1+1–Max. add-on N.C. auxiliary contacts (CA4, CAL4, VEM4):1 max. with 1 CE5 on positions 1, 2, 3, 4AF26, AF384 0 0 01+ 3 max.–+1–1+ 2 max.+ 1––AF09, AF162 2 0 01+ 3 max.–+1–AF26, AF38Max. add-on N.C. auxiliary contacts (CA4, CAL4, VEM4):1 max. with 1 CE5 on positions 1 ±30°, 5AF09, AF164 0 0 01+ 3 max.–+1–1+ 2 max.+ 1––No add-on N.C. auxiliary contacts on positions 1 ±30°, 5AF26, AF384 0 0 01+ 3 max.–––AF09, AF162 2 0 0AF26, AF382 2 0 0Max. add-on N.C. auxiliary contacts (CA4, CAL4):4 max. with 1 CE5, 2 max. with 2 CE5 on positions 1, 1 ±30°, 2, 3, 4, 5AF40 ... AF804 0 0 02+ 2 max.–+1+ 11+ 3 max.–+1+ 1No add-on N.C. auxiliary contacts on positions 1, 1 ±30°, 2, 3, 4, 5AF40, AF802 2 0 01+ 3 max.–––03
1SBC101907S0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/237—Auxiliary contact blocks for severe industrial environmentsFor NF contactor relaysMain accessory fitting details - for ordering details, technical data and other accessories: see section accessoriesMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.Contactor relaytypesMainpolesFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksAuxiliary contact blocksLeft sideRight side1-pole CE51-pole CA42-pole CAL4-11Max. add-on N.C. auxiliary contacts (CA4, CAL4): 1 max. with 1 CE5 on positions 1, 2, 3, 4NF2321EE1+ 3 max.–+1–Max. add-on N.C. auxiliary contacts (CA4, CAL4): 2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4NF4 0E2+ 2 max.–––1+ 3 max.–+1–1+ 1 max.–+1+ 1Max. add-on N.C. auxiliary contacts (CA4): none with 1 CE5 on positions 1 ±30°, 5NF2321EE1+ 3 max.–––Max. add-on N.C. auxiliary contacts (CA4, CAL4): 1 max. with 1 CE5 on positions 1 ±30°, 5NF4 0E1+ 3 max.–+1–03
—Auxiliary contact blocks for AF116 ... AF2850 contactorsThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for side mounting:•CAL 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors.The CAL ...-11B is a second block for mounting in addition to a first CAL ...-11 block, right- and/or left-hand of the AF116 ... AF2850 contactors.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce)kgSide-mounted instantaneous auxiliary contact blocksAF116 ... AF3701 1CAL19-111SFN010820R101110.0401 1CAL19-11B1SFN010820R331110.040AF400 ... AF28501 1CAL18-111SFN010720R101120.0501 1CAL18-11B1SFN010720R331120.050For each contactor type, refer to "Accessory fitting details" table.1SFC101071V0001CAL19-111SFC101082V0001CAL18-113/238ABB MOTOR PROTECTION AND CONTROL1SFC101097C0201 - Rev. A03
1SFC101116C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/239—Auxiliary contact blocks for AF116 ... AF2850 contactorsTechnical dataTy pesCAL18CAL19Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp.6 kVRated operational voltage Ue max.24...690 V ACConventional thermal current Ith - θ ≤ 40 °C16 ARated frequency (without derating)50/60 HzIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A380-440 V 50/60 Hz 3 A500-690 V 50/60 Hz 2 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W3 A / 72 W48 V DC 2.8 A / 134 W1.5 A / 72 W72 V DC 1 A / 72 W1 A / 72 W110 V DC 0.55 A / 60 W0.55 A / 60 W125 V DC 0.55 A / 69 W0.55 A / 69 W220 V DC 0.3 A / 66 W0.3 A / 69 W250 V DC 0.3 A / 75 W0.3 A / 75 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacity24 V / 50 mA (0.5 million of operating cycles)24 V / 50 mAwith failure rate acc. to IEC 60947-5-4≤ 10-6Power dissipation per pole at 6 A0.15 WMechanical durabilityNumber of operating cycles3 millions (A/AF400 ... AF750)0.5 million (AF1250 ... AF2050)5 millions operating cyclesMax. switching frequency3600 cycles/h300 cycles/hMax. electrical switching frequencyAC-151200 cycles/h300 cycles/hDC-13900 cycles/h300 cycles/hMirror contacts acc. to annex F of IEC 60947-4-1N.C. auxiliary contacts are mirror contacts (1)(1) CAL19: for 3-pole contactors only.Contact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 V AAC maximum volt-ampere breaking720 V ADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 V AConnecting characteristicsConnection capacity (min. ... max.)Solid / stranded1 x 1...4 mm²2 x 1...4 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 8 mml >3.7 mmConnection capacity acc. to UL/CSA1 or 2 xAWG18...14Stripping length9 mmTightening torque1 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
1SFC101125C0201 - Rev. A3/240ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for AF116 ... AF2850 contactors for severe industrial environmentsThe auxiliary contact blocks are used for the operation of auxiliary and control circuits for severe industrial environments.Types of auxiliary contact blocks for side mounting:•CEL1-pole block, with built-in microswitch IP67 degree of protection (IP20 on terminals). Instantaneous N.O. or N.C. contact.For clipping onto the right- and/or left-hand side of the contactors.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgSide-mounting instantaneous auxiliary contact blocksAF116 ... AF3701 0CEL19-101SFN010832R101010.0400 1CEL19-011SFN010832R100110.040AF400 ... AF28501 0CEL18-101SFN010716R101010.0500 1CEL18-011SFN010716R100110.050For each contactor type, refer to "Accessory fitting details" table.1SFC101214V0001CEL191SFC101083V0001CEL1803
1SFC101129C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/241—Auxiliary contact blocks for AF116 ... AF2850 contactorsfor severe industrial environmentsTechnical dataTy pesCEL18, CEL19Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1250 VRated operational voltage Ue max.125 VConventional thermal current Ith - θ ≤ 40 °C0.1 AIe / Rated operational current AC-14acc. to IEC 60947-5-124-127 V 50/60 Hz 0.1 AMaking capacity acc. to IEC 60947-5-16 x Ie AC-14Breaking capacity acc. to IEC 60947-5-16 x Ie AC-14Ie / Rated operational current DC-12acc. to IEC 60947-5-124 V DC 0.1 A48 V DC 0.1 A72 V DC 0.1 A110 V DC 0.1 A220 V DC–Short-circuit protection device0.1 A (FF type fuses) (1)Minimum switching capacitywith failure rate acc. to IEC 60947-5-43 V / 1 mAMechanical durabilityNumber of operating cycles1 million (2)Max. switching frequency1200 cycles/h (2)Electrical durabilityNumber of operating cycles0.7 millions (2)Max. switching frequencyAC-14, AC15 1200 cycles/h (2)DC-12900 cycles/h (2)Mirror contacts acc. to annex F of IEC 60947-4-1N.C. auxiliary contacts are mirror contactsContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage125 VPilot dutyAC thermal rated current0.1 AConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 7.7 mml >3.7 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Tightening torque1 NmDegree of protection TerminalsIP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529MicroswitchesIP67Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2(1) or HRC fuses for very fast action (6.3 x 32 mm size).(2) For CEL19, please consult us.03
1SBC101641S0201 - Rev. A3/242ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for AF09 ... AF96 contactors and NF contactor relaysElectrical durabilityElectrical durability for AC-15 utilization categoryAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1: -making current: 10 x Ie with cos φ = 0.7 and Ue - breaking current: Ie with cos φ = 0.4 and Ue.These curves represent the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.Electrical durability for DC-13 utilization categoryDC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current Ie and Ue. -AF09 ... AF96 contactor built-in auxiliary contacts - 1-pole and 4-pole CA4, 2-pole CAT4, 1-pole CC4, 2-pole CAL4 add-on auxiliary contacts.Example:Breaking current = 1 AOn the opposite curve at intersection "O" 1 A the corresponding value for the electrical durability is approxi-mately 2 millions operating cycles. -AF09 ... AF96 contactor built-in auxiliary contacts 1-pole and 4-pole CA4, 2-pole CAT4, 1-pole CC4, - 2-pole CAL4 add-on auxiliary contacts, - NF contactor relays.Example:Control of DC electro-magnet: Ue voltage = 72 V DC and breaking power = 70 W.On the opposite curve at intersection "O" 72 V / 70 W the corre-sponding value for the electrical durability is approximately 2 millions operating cycles.NF contactor relays.(For add on auxiliary contacts see curve above).Breaking current (A)0.020.050.10.30.51245100.10.20.30.51235102030Million operating cycles360.2Breaking current (A)0.020.050.10.30.51245100.10.20.30.51235102030360.2Million operating cyclesVoltage (V)Breaking power (W)101105205021007020 2425010020050050721.10 cycles63.10 cycles610.10 cycles603
1SFC101117C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/243—Auxiliary contact blocks for AF116 ... AF2850 contactorsElectrical durabilityElectrical durability for AC-15 utilization categoryAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:• making current: 10 x Ie with cos φ = 0.7 and Ue• breaking current: Ie with cos φ = 0.4 and Ue.This curves represent the electrical durability of the add-on auxiliary contacts, in relation to the breaking current.The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.• AF116 ... AF2850 contactors auxiliary contacts• 2-pole CAL18 and CAL19 add-on auxiliary contacts Example:Breaking current = 1.2 AOn the opposite curve at intersection "O" 1.2 A the corresponding value for the electrical durability is approxi-mately 2.7 millions operating cycles.Breaking current (A)0.020.050.10.30.51245100.10.20.30.51235102030Million operating cycles360.21.22.703
1SBC101660S0201 - Rev. A3/244ABB MOTOR PROTECTION AND CONTROL—Add-on auxiliary contactsTerminal marking and positioning4-pole auxiliary contacts1-pole auxiliary contacts-1NC-2CA4-01 (1)-3NO-4CA4-10 (1)-5NC-6CC4-01-7NO-8CC4-102-pole auxiliary contactsCAL4-11 (1) (Left-side mounted)13X / NO14X / 21X / NC22X / 44X43X31X32XCAL4-11 (1) (Right-side mounted)NCNO31X / 22X32X / 21X43X / 14X44X / 13XC AT4 -1 1M21NC2233NO34C AT4 -1 1E13NO1421NC22C AT4 -1 1U-3NO-4-1NC-2CA4-40E (1)1314232433344344NONONONOCA4-13M (1)31324142NCNC5354NO2122NCCA4-40U-3-4-3-4-3-4-3-4NONONONOCA4-13N (1)6162535481827172NONCNCNCCA4-31E (1)2122131443443334NONCNONOCA4-31M (1)2122333443445354NONONONCCA4-31U 1 2 3 4 3 4 3 4NONCNONOCA4-40N (1)5354636473748384NONONONOCA4-22E (1)2122131443443132NONCNCNOCA4-22M (1)2122313243445354NO NONCNCCA4-22U 1 2 3 4 3 4 1 2NONCNCNOCA4-31N (1)5354616273748384NONONONCCA4-04E2122111241423132NCNCNCNCCA4-04M (1)3132212251524142NCNCNCNCCA4-22N (1)6162535483847172NONCNCNOCA4-04N (1)6162515281827172NCNCNCNC21X /22X /13X /14X /NONC43X44X31X32XCAL18-11, CAL19-11(Left-side mounted)NCNO83X /84X /71X /72X /61X62X53X54XCAL18-11B, CAL19-11B(Right-side mounted)61X /62X /53X /54X /NONC83X84X71X72XCAL18-11B, CAL19-11B(Left-side mounted)NCNO43X /44X /31X /32X /21X22X13X14XCAL18-11, CAL19-11 (Right-side mounted)(1) available with Push-in Spring terminals03
1SBC101669S0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/245—Electronic timersTEF4 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFF-delay versions.Compact solution in cabinet compared to separate timersTEF4 electronic timers are front-mounted and locked on AF contactors or NF contactor relays. A mechanical indicator allows to show the state of the contactor.Safe and cost-reduced wiringTEF4 electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil.Available for a wide control voltage range 24...240 V AC/DCTEF4-ON or TEF4-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted by means of a rotary switch. The timing function is activated by closing or opening the device on which the timer is mounted. The OFF-delay version operates without additional control supply.For contactors,contactor relaysTime delay rangeselected by switchDelaytypeRated control circuit voltage UcAuxiliary contactsTy pe Order codeWeightPkg(1 pce)V 50/60 Hz or DCkgWith screw terminalsAF09 ... AF96NF0.1...1 s1...10 s10...100 sON-delay24...2401 1TEF4-ON1SBN020112R10000.065OFF-delay24...2401 1TEF4-OFF1SBN020114R10000.065With spring terminalsAF09 ... AF96NF0.1...1 s1...10 s10...100 sON-delay24...2401 1TEF4S-ON1SBN020113R10000.065OFF-delay24...2401 1TEF4S-OFF1SBN020115R10000.065TEF4-ON1sbc100004V0014TEF4-OFF1SBC100012V0014TEF4S-ON1SBC101394F0014TEF4S-OFF1SBC101394F001403
1SBC101670S0201 - Rev. B3/246ABB MOTOR PROTECTION AND CONTROL—Electronic timersTechnical dataContact utilization characteristics according to IECTypesTEF4-ONTEF4-OFFStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1400 VRated impulse withstand voltage Uimp4 kVRated operational voltage Ue max.240 VRated frequency (without derating)50 / 60 HzConventional thermal current Ith - θ ≤ 40 °C5 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 3 A220-240 V 50/60 Hz 1.5 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 1 A / 24 WShort-circuit protection device gG type fuse6 ARated short-time withstand current Icwfor 1.0 s8 Aθ = 40 °Cfor 0.1 s8 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-424 V DC 10-7Power dissipation per pole at 3 A0.1 WFunction diagramON-delayOFF-delayUc (A1 - A2)N.O. (67 - 68)t100 msmin.150 msmin.N.C. (55 - 56)Uc (A1 - A2)N.O. (67 - 68)t100 msmin.1 smin.N.C. (55 - 56)Bistable relay inside. Before use, once apply Uc then switch it off in order to initialize position of the contacts.Control circuit voltage AC control voltageRated control circuit voltage Uc24...240 V AC50/60 HzAverage consumption1.5 mA RMS1 mA RMSDC control voltageRated control circuit voltage Uc24...240 V DCAverage consumption1.5 mA1 mARated frequency limits50 / 60 HzSupply voltage range0.85...1.1 x Uc (at θ ≤ 70 °C)Overvoltage protectionVaristor includedTime delay range (t) selected by switch0.1...1 s1...10 s10...100 sOn-load reiteration accuracy under constant conditions≤ 1 %Minimum ON period0.1 s1 sRecovery time0.15 s0.1 sAmbient air temperatureOperation-25 °C ... +70 °CStorage-40 °C ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude2000 mMounting positionsMounting positions 1, 1 +/- 30°, 2, 3, 4, 5Shock withstand1/2 sinusoidal shock for 11 ms: no change in contact positionacc. to IEC 60068-2-27 and EN 60068-2-27Same as contactor or contactor relay(Mounting position 1)Vibration withstand5...300 Hzacc. to IEC 60068-2-63 g closed position / 2 g open positionMechanical durabilityNumber of operating cycles5 millions operating cyclesMax. switching frequency3600 cycles/h1800 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/h03
1SBC101670S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/247240110100101001000Voltage (V)Breaking power (W)1.106 cyclesElectrical durability for DC-13 utilization categoryDC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current Ie and Ue.—Electronic timersTechnical dataContact utilization characteristics according to UL / CSATy pesTEF4-ONTEF4-OFFStandardsUL 508, CSA C22.2 N°14Rated insulation voltage Ui acc. to UL / CSA300 VMax. operational voltage240 VPilot dutyB300, R300AC thermal rated current5 AAC maximum volt-ampere making3600 VAAC maximum volt-ampere breaking360 VADC thermal rated current1 ADC maximum volt-ampere making-breaking28 VAConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm² (0.75 ... 1.5 mm² with spring terminals)2 x 0.75...1.5 mm² (0.75 ... 1.5 mm² with spring terminals)LlLugsL ≤ 8 mm (1)l >3.7 mm (1)Connection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torque1.2 N.m / 11 lb.in (1)Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals should be tightenedAll terminalsM3.5 Screwdriver typeFlat Ø 5.5 / Pozidriv 2Spring terminalsScrewdriver typeØ 3.5Terminal MarkingA1A256 NC68 NO55 NC67 NOKM1A1A256 NC68 NO55 NC67 NOKM1(1) Not applicable for TEFAS-ON and TEF4S-OFF with spring terminal Spring terminals)03
A2A201NC01NCKM1KM21SFC101035V0014—InterlocksMechanical interlock unitsThe VM mechanical interlock units are designed for the interlocking of two AF contactors. When mounted between two contactors, the VM mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed. The mechanical interlock units VM4 and VM96-4 include 2 fixing clips (BB4).For contactors MountingTy pe Order codePkg qtyWeight(1 pce)kgMechanical interlock units for two contactors mounted side by sideAF09 ... AF38..-30-..VM41SBN030105T1000100.005AF09 ... AF38..-40-00AF40 ... AF96-30-..AF40 ... AF80-40-00VM96-41SBN033405T1000100.006For same size contactors:VM191SFN030300R100010.054AF116 ... AF146AF190, AF205AF265 ... AF370AF116 ... AF146 and AF190, AF205VM140/1901SFN034403R100010.088AF190, AF205 and AF265 ... AF370VM205/2651SFN035203R100010.090AF265 ... AF370 and AF400 ... AF460VM370/4001SFN035403R100010.100AF400 ... AF1250PN.. mounting plate to be orderedseparatelyVM750H1SFN035700R100010.200AF1350 ... AF2650Plate includedVM1650H1SFN036503R100116.000Mechanical interlock units for two contactors mounted one above the otherAF400 ... AF1250Additional plate (not supplied)VM750V1SFN035701R100010.200Mechanical and electrical interlock setsVEM4 mechanical and electrical interlock set for the interlocking of two AF contactors. VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock block with A2-A2 connection. Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection diagram.For contactors AuxiliarycontactsTy pe Order codePkg qtyWeight(1 pce)kgMechanical and electrical interlock setFor same size contactors:AF09 ... AF16..-30-..AF26 ... AF38..-30-00AF09, AF16..-40-00AF26, AF38..-40-000 2VEM41SBN030111R100010.035Fixing clipsAF09 ... AF96BB41SBN110120W1000500.002Note: VEM4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC (coil 20) and 24 V DC (coil 30). VM19BB4VM41SBC100010V0014VEM41SBC100011V00141SBC100013V00143/248ABB MOTOR PROTECTION AND CONTROL1SBC101595S0201 - Rev. B03
1SBC101594S0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/249—InterlocksTechnical dataMechanical interlock unitTy pesVM4, VM96VM19 ... VM750VM1650HMechanical durabilityNumber of operating cycles5 millions operating cycles1 million operating cycles500 000 operating cyclesMax. mechanical switching frequency1800 cycles/h300 cycles/hMechanical and electrical interlock setContact utilization characteristics according to IECTy pesVEM4StandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp.6 kVRated control circuit voltage UcAC 50/60 Hz control voltage24...500 V ACDC control voltage20...500 V DCConventional thermal current Ith - θ ≤ 40 °C16 AMechanical durabilityNumber of operating cycles5 millions operating cyclesMax. mechanical switching frequency1800 cycles/hElectrical durabilityMax. electrical switching frequency1200 cycles/hContact utilization characteristics according to UL / CSATy pesVEM4StandardsUL 508, CSA C22.2 N°14Max. operational voltage500 V AC, 500 V DCConnecting characteristicsTy pesVEM4Connection capacity (min. ... max.)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length10 mmTightening torque1.2 Nm / 11 lb.inDegree of protection IP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
—Impulse contact blocksImpulse contact blocks are designed for use in enclosures, in association with an adjustable mechanical pushbutton. Two types are available:•CB5-10: N.O. contact with a black actuator ("ON" function)•CB5-01: N.C. contact with a light grey actuator ("OFF" function).These blocks are equipped with 2 connecting leads 0.5 mm² with end, approximately 18 cm long.Mounting: Clipped onto the front face of the contactors.For contactors ContactsTy pe Order codePkg qtyWeight(1 pce)kgAF09 ... AF961–CB5-101SBN010013R101010.012–1CB5-011SBN010013R100110.012CB51SBC100039V00149.80.39"CB5-1036 1.42"10 0.39"22.9 0.90"9.80.39"CB5-0136 1.42"21.6 0.85"5 0.2"Main dimensions mm, inches3/250ABB MOTOR PROTECTION AND CONTROL1SBC101655S0201 - Rev. C03
ABB MOTOR PROTECTION AND CONTROL 3/25103—Notes
—RA4 interface relaysRA4 interface relay is designed to receive 24 V DC signals delivered by PLC’s or other sources with a low output power and to restore them with sufficient power to operate the coils of the relevant AF09 ... AF96 contactors or the NF contactor relays. RA4 interface relay is made up of a miniature electromechanical relay equipped with a N.O. contact and with a low consumption 24 V DC coil.The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power contactor.Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators and, more generally, on component lifetime. The RA4 is protected from surge thanks to the built-in surge protection of AF09 ... AF96. Furthermore, the RA4 is protected against relay pole reversal by a diode inserted between the E1 and E2 input terminals.ConnectionThe "E1+" and "E2–" input terminals must be connected, according to their polarity, to the PLC-output.The RA4 is equipped with two terminal pads for connection to the A1 and A2 terminals of the contactor coil.This coil is supplied between the A0 and A2 terminals of the RA4.MountingRemove the coil terminal block from the contactor and clip the interface relay without any screw-ing operation.For contactors (1)Coil voltages (2)Rated control circuit voltage UcType Order codePkg qtyWeight(1 pce)V AC 50/60 Hz (4)V DCkgAF09 ... AF96NF24 ... 25024RA41SBN060100R100010.040RA4-T (3)1SBN060100T1000100.040(1) LDC4 additional terminal blocks and CAT4 auxiliary contact blocks not suitable with R A4.(2) Main use with contactor coils 41, 11, 12, 13.(3) On request. Please contact your ABB local sales organization.(4) 24 V DC on request.1SBC101065V0014RA4RA4 mounted on AF09 ... AF38AF40 ... AF96A80 mm / 3.15" 119.5 mm / 4.70"B63 mm / 2.48" 83 mm / 3.27"C45 mm / 1.77" 40 mm / 1.57"CAB==44.8 1.76"40 1.57"230.91"Main dimensions mm, inchesWiring diagram* 24 V DC on request.24 V DCA0E2--+E1+KM1A1A2PLCOutputA2RA4≤250 V AC *Uc3/252ABB MOTOR PROTECTION AND CONTROL1SBC101060S020103
1SBC101061S0201 ABB MOTOR PROTECTION AND CONTROL 3/253—RA4 interface relaysTechnical dataUtilization characteristics according to IECTy peRA4StandardsIEC 60947 5-1Rated insulation voltage Ui acc. to IEC 60947 5-1250 V AC 50/60 HzAmbient air temperature In free air operationat Uc = 24 V DC (between E1 and E2) -25 ... +70 °Cfrom 0.85 to 1.1 x Uc -25 ... +60 °CStorage-40 ... +70 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude≤3000 mMounting positionsMounting positions 1, 1 ±30°, 2, 3, 4, 5Connecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1 ... 2.5 mm²2 x 1 ... 2.5 mm²Flexible with non insulated ferrule1 x 0.75 ... 2.5 mm²2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x 0.75 ... 2.5 mm²2 x 0.75 ... 1.5 mm²LlLugsL <8 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18 ... 14Stripping length10 mmTightening torque1.2 Nm / 11 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20 protection against direct contact in acc. with EN 50274RA4 wired and mounted on the associated contactorScrew terminalsDelivered in open positionAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Working dataSurge suppressionFor interface relay coilIncluded inside AF built-in surge protectionProtection against polarity reversal between terminals E1 and E2DiodeInterface relay operating timeClosing and drop-out ≤10 msTotal operating timeinterface relay + contactor (1)Between energization and:N.O. contact closing42 ... 95 ms (AF09 ... AF38, NF) 44 ... 105 ms (AF40 ... AF96)N.C. contact opening40 ... 90 ms (AF09 ... AF38, NF) 40 ... 100 ms (AF40 ... AF96)Between de-energization and:N.O. contact opening15 ... 57 ms (AF09 ... AF38, NF) 21 ... 107 ms (AF40 ... AF96)N.C. contact closing17 ... 60 ms (AF09 ... AF38, NF) 23 ... 112 ms (AF40 ... AF96)(1) For contactor coils 41, 11, 12, 13.Electrical input dataControl voltage (E1 and E2 terminals) UcRated value24 V DCMax. range at ambient temperature 20 °C19 ... 30 V DCMax. consumption for Uc = 24 V DC, θ = 20 °C0.3 W"0" status (relay open)for Uc≤2.4 V DCfor Ic<1 mA"1" status (relay closed) for Uc≥19 V DCMax. short supply interruption immunity time2 msElectrical output dataSwitching voltage (A0 and A2 terminals)≤250 V ACElectrical durabilitySwitching frequency600 cycles/hNumber of operating cycles2 million operating cycles03
1SBC100204S02013/254ABB MOTOR PROTECTION AND CONTROL1SBC101058V0014E1E2A1A2Wiring diagramWA4B100.39"60 2.36"411.61"5.5 0.22"3 0.12"A—Mechanical latching unitWA4 + AF09 ... AF96, NF 1-stack The WA4 mechanical latching unit for AF09 ... AF96 contactors and NF contactor relays ensures that the contactor or contactor relay remains switched on even if there is a lack or a failure of voltage. Standard contactors can be easily converted into compact latched contactors.The WA4 block contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching.OperationAfter closing, the contactor continues to be held in the closed position by the latching mechanism should the supply voltage fail at the contactor coil terminals. Contactor opening can be controlled:•electrically by an impulse (AC or DC) on the WA4 block coil (the coil is not designed to be perma-nently energized)•manually by pressing the pushbutton on the front face of the WA4 block.MountingThe WA4 block is clipped onto the front face of the 1-stack contactor where it takes up two slots in central position (see fig. below). The two other slots may accept CA4 single pole auxiliary contacts (1 block on each side of the mechanical latch).Additional CAL4 can be fitted on the side of the contactor in respect to the total number of built-in or additional N.O. and N.C. auxiliary contacts as described in the accessory fitting details part of each contactor type.For contactors and contactor relaysRated control circuit voltage UcTy pe Order codePkgqtyWeight(1 pce)V AC 50/60 Hz V DCkgAF09 ... AF65, NF 1-stack24...6024...60WA4-111SBN040100R101110.08048...13048...130WA4-121SBN040100R101210.080100...250100...250WA4-131SBN040100R101310.080250...500250...500WA4-141SBN040100R101410.080AF80, AF9624...6024...60WA4-96-111SBN040200R101110.08048...13048...130WA4-96-121SBN040200R101210.080100...250100...250WA4-96-131SBN040200R101310.080250...500250...500WA4-96-141SBN040200R101410.080Mechanical latching unit for 24 V DC - 500 mA PLC controlAF09 ... AF38, NF 1-stack–24WA4-101SBN040100R101010.080Note: For WA4 accessory use with contactor or contactor relay coil 30, please consult your ABB local sales organization.For contactors and contactor relaysAmm in.Bmm in.AF09 ... 16(Z)-30-..AF09 ... 16(Z)-40/22-00NF(Z)45 1.77"133.5 5.25"AF26 ... 38(Z)-30-0045 1.77"142.5 5.61"AF26 ... 38(Z)-40/22-00 45 1.77"157.5 1.77"AF40 ... 65-30-0055 2.16"167 6.57"AF40-40/22-0070 2.75"170 6.70"AF52-40-0070 2.75"170 6.70"AF80, 96-30-0070 2.75"172 6.77"AF80-40/22-0090 3.54"172 6.77"Main dimensions mm, inches03
1SBC100205S0201 ABB MOTOR PROTECTION AND CONTROL 3/255—Mechanical latching unit Technical dataTy pesWA4, WA4-96WA4Coil voltage code11, 12, 13, 1410StandardsIEC 60947-4-1Rated insulation voltage Uiacc. to IEC 60947-1690 V ACCoil operating limitsAC supplyAt θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max–acc. to IEC 60947-4-1DC supply At θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc maxAt θ ≤ 70 °C 0.85 x Uc ... 1.1 x UcControl circuit voltageAC control voltage 50/60 HzRated control circuit voltage Uc24 ... 500 V AC 50/60 Hz–Coil consumptionAverage pull-in value15 ... 100 VA–DC control voltage 50/60 HzRated control circuit voltage Uc24 ... 500 V DC24 V DCCoil consumptionAverage pull-in value15 ... 100 W12 WMax. electrical impulse timeOn AC control supply (with load factor 1.6%)4 s–On DC control supply (with load factor 1.6%)4 sMin. electrical impulse timeFor latching, energizing of the contactor coil120 msFor unlatching, energizing of the mechanical latching unit coil50 msOperating timeOn contactor closing (latching) between coil energization and:N.O. contact closingNo difference with the operation of a contactor without mechanical latching unitN.C. contact openingNo difference with the operation of a contactor without mechanical latching unitOn contactor opening (unlatching) between mechanical latching unit coil energization and:N.O. contact opening8 ... 15 msN.C. contact closing10 ... 17 msAmbient air temperatureOperation-25 ... +70 °CStorage-60 ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMax. operating altitude≤ 3000 mMounting positionsMounting positions 1, 1+/- 30°, 2, 3, 4, 5Mechanical durabilityAF09 ... AF38, NF: 1 million operating cyclesAF40 ... AF65: 0.5 million operating cyclesAF80, AF96: 0.2 million operating cyclesMax. switching frequencywith on-load factor of 1.6%cycles/h600Connecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1 ... 2.5 mm²2 x 1 ... 2.5 mm²Flexible with non insulated ferrule1 x 0.75 ... 2.5 mm²2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x 0.75 ... 2.5 mm²2 x 0.75 ... 1.5 mm²L6LugsL <8 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18 ... 14Stripping length10 mmTightening torque1.2 Nm / 11 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open positionAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
—Other accessoriesFor contactorsTy peOrder codePkg qtyWeight(1 pce)kgAdditional coil terminal blocks with screw terminal Additional coil terminal blocks for a bottom access to the coil terminals of contactors or contactor relays.AF09 ... AF96, NFLDC41SBN070156T1000100.010Additional coil terminal blocks with Push-in Spring terminalAF09 ... AF96, NFLDC4K1SBN070159T100010 0.010Protective coversSealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.AF09 ... AF96 1-stack contactors and NF contactor relaysBX41SBN110108T1000100.0064-pole CA4, 2-pole CAT4 auxiliary contact blocks andTEF4 electronic timerBX4-CA1SBN110109W1000500.001Note: BX4 produced since 13045 (day 045 - year 2013) are suitable for AF40 ... AF96.Function markers AF09 ... AF370Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking table to identify your contactors, overload relays or manual motor starters. Marker dimensions: 7 x 20 mm (.276" x .787").AF09 ... AF370 contactors, TF thermal overload relays, EF electronic overload relays and MS116, MS132 manual motor startersBA41SNA235156R2700160.011AMS 500 support plate for 8 BA4SPRC 11SNA360010R150010.220HTP500 support plateHTP500-BA41SNA235712R240010.290Function markers AF400 ... AF2850Set of 50 function markers designed to be clipped onto the front face of devices. Details can be added to these markers using a ball point pen, indelible felt-tip pen or pentel white. Self-adhesive labels (not supplied) can also be added to them. Marker dimensions: 7 x 19 mm (.276" x .748").AF400 ... AF2850 and accessoriesBA5-501SBN110000R100010.0171SBC100021V0014BX4BA5-501SBC100044V001428 1.10"60.24"44.8 1.76"BX4LDC41SBC100020V0014BX4-CA1SBC100023V0014BA41SNC160101F0014Main dimensions mm, inchesLDC4K1SBC100090V00143/256ABB MOTOR PROTECTION AND CONTROL1SBC101733S020103
1SBC101752S0201 - Rev. A—Other accessoriesFor contactorsTy peOrder codePkg qtyWeight(1 pce)kgMounting piecesMounting piece for replacing installed contactors fixed by screws by AF contactors.From contactorTo contactorA26 ... A40, AL26 ... AL40AF09 ... AF38BP38-41SBN112303T1000100.003A50 ... A75, AE50 ... AE75, AF50 ... AF75 AF40 ... AF65BP65-41SBN113403T1000100.004A95, A110, AE95, AE110, AF95, AF110AF80 ... AF96BP96-41SBN113903T1000100.005Test blockBDT4 test block is suitable for switching on contactor off-load. Marking on the block indicates the contactor type to fit with.AF09...AF96 3-pole, NFBDT41SBN110122T1000100.007Main dimensions mm, inchesø 4.2 0.17"54 2.13"5 0.20"5 0.20"45 1.77"70 2.76"80 3.15"90 3.54"M4 8-32 UNCBP38-478 3.07"13 0.51"136 5.35"126 4.96"ø 6.2 0.24"M6 1/4-20 UNC5 0.20"4.6 0.18"90 3.54"147.7 5.81"BP96-45 0.20"119.5 4.70"100 3.94"90 3.54"ø 6.2 0.24"M6 1/4-20 UNC60 2.36"10 0.39"4.6 0.18"70 2.76"BP65-4BP38-41SBC100022V00141SBC100041V0014BDT4For AF09 ... AF65, NF1SBC100042V0014BDT4For AF80 ... AF96 ABB MOTOR PROTECTION AND CONTROL 3/25703
1SBC101734S02013/258ABB MOTOR PROTECTION AND CONTROL—Additional terminal blocksThe LD terminal block is designed to increase the connecting capacity of 3-pole AF26 ... AF38 contactors on which it is fitted and for preparation of the wiring before final connection to the contactor. LD38-4 blocks are 3-pole terminal blocks with tunnel terminals.For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAF26 ... AF38LD38-41SBN072308R100020.070Technical dataTy pesLD38-4Rated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VMain terminalsScrew terminals with double connector2 x (7 width x 5.8/9.2 depth)Connection capacity (min. ... max.)RigidSolid (≤ 4 mm²)1x 2.5...25 mm²Stranded (≥ 6 mm²)1x 2.5...25 mm² + 1x 2.5...16mm² Flexible with non insulated ferrule1x 2.5...16 mm²1x 2.5...16mm² + 1x 2.5...10mm²Flexible with insulated ferrule1x 2.5...16mm²1x 2.5...16mm² + 1x 2.5...10mm²Connection capacity acc. to UL / CSA1x AWG 8-42x AWG 8-6Stripping length14 mmTightening torque2.5 Nm / 22 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in closed position, screws of unused terminals must be tightenedMain terminalsM5Screwdriver typeFlat Ø 6.5 / Pozidriv 2Note: The utilization of LD38-4 additional terminal blocks does not allow the use of BER and BEY connection sets.LD38-41SBC100038V0014102 4.02"125 4.92"30 1.18"Main dimensions mm, inches03
1SFC101099C0201 - Rev. C ABB MOTOR PROTECTION AND CONTROL 3/259—Terminal shroudsMain terminal protection for AF40 ... AF1250 contactors.The auxiliary contact blocks and coils are designed to provide an IP 20 degree of protection.The main terminals, equipped with compression lugs or cable clamps, can be protected against accidental direct contact after wiring (EN 50274) by the addition of terminal shrouds (see table below).For contactorsTy pe Order codePkg qtyWeight(1 pce)kg3-pole contactorsAF40 ... AF65LT65-301SBN123401R100010.015AF80, AF96LT96-301SBN123901R100010.020AF116 ... AF146, with compression lugsLT140-30L1SFN124203R100020.070AF190, AF205, with cable clampsLT205-30C1SFN124801R100020.050AF190, AF205, with compression lugsLT205-30L1SFN124803R100020.220AF190, AF205, with shorting bar or between contactor and TOL/EOL in DOL starters LT205-30Y1SFN124804R100010.050AF265 ... AF370, with cable clampsLT370-30C1SFN125401R100020.035AF265 ... AF370, with compression lugsLT370-30L1SFN125403R100020.280AF265 ... AF370, with shorting bar or between contactor and TOL/EOL in DOL startersLT370-30Y1SFN125404R100010.075AF265 ... AF370, for use with extending cable clamps, ATK300/2 and OZXB4LT370-30D1SFN125406R100010.15 AF400, AF460 with cable clampsLT460-AC1SFN125701R100020.100AF400, AF460 with compression lugsLT460-AL1SFN125703R100020.800AF580, AF750 with cable clampsLT750-AC1SFN126101R100020.120AF580, AF1250 with compression lugsLT750-AL1SFN126103R100020.8254-pole contactorsAF40, AF52LT52-401SBN123402R100010.020AF80LT80-401SBN123902R100010.025AF116 ... AF140, with compression lugsLT140-40L1SFN124203R200020.090AF190 ... AF205, with cable clampsLT205-40C1SFN124801R200020.035AF190 ... AF205, with compression lugsLT205-40L1SFN124803R200020.140AF265 ... AF370, with cable clampsLT370-40C1SFN125401R200020.040AF265 ... AF370, with compression lugsLT370-40L1SFN125403R200020.165Note: With LT65-30, LT96-30, LT52-40, LT80-40, use rigid cables or flexible cables with insulated ferrules including a stripping length ≥ 18 mm.Connecting characteristics with LT ... terminal shroudsContactor typesAC / DC operatedAF40 ... 65 + LT65 ... AF80 ... 96 + LT ...Screw terminals with double connector2 x (9.3 width x 7.9/10.3 depth)Screw terminals with double connector2 x (12.4 width x 9.3/11.1 depth)Connection capacity (min. ... max.)Main contactor (poles)Rigid solid1 x 6...16 mm² or 25 ...35 mm²6...16 mm² or 25 ...70 mm²2 x 6...16 mm² or 25 ...35 mm²6...16 mm² or 35 ... 50 mm²Flexible with insulated ferrule1 x 4...16 mm² or 25 ...35 mm²6...16 mm² or 25 ...50 mm²2 x 4...16 mm² or 25 ...35 mm²6...16 mm² or 35 ...50 mm²L6Bars or LugsL <9.2 mm12.2 mmConnection capacity acc. to UL / CSA1 x AWG 10...6 or AWG 4..2AWG 6 or AWG 4..12 x AWG 10...6 or AWG 4..2AWG 6 or AWG 2..1Stripping length18 mm18 mmTightening torqueRecommended4 Nm / 35 lb.in6 Nm / 53 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminals equipped with LTIP20Screw terminalsMain terminalsM6M8Screwdriver typeFlat Ø 6.5 / Pozidriv 2hexagon socket (s = 4 mm)1SBC100073V0014LT65-301SFC101038V0001LT140-30L1SFC101041V0001LT370-30C1SFC101089V0001LT460-AC1SBC100075V0014LT80-401SFC101199V0001LT205-4003
—ConnectionsTerminal enlargementsEnlargement pieces designed to increase the width of the contactor terminal pads in order to al-low larger connections to be mounted.For contactors DimensionsTy pe Order codePkg qtyWeight(1 pce)hole Ø mmbar mmkg3-pole contactorsAF116 ... AF1466.513 x 3LW1401SFN074207R100010.115AF190, AF20510.517.5 x 5LW2051SFN074807R100010.260AF265 ... AF37010.525 x 5LW3701SFN075407R100010.340AF400, AF46010.525 x 5LW4601SFN075707R100010.730AF580, AF7501340 x 6LW7501SFN076107R100011.230AF12501350 x 10LW12501SFN076407R100012.0004-pole contactorsAF190 ... AF20510.520 x 5LW205-401SFN074807R200010.306AF265 ... AF37010.525 x 5LW370-401SFN075407R200010.540Terminal extensionExtension pieces designed to extend the main terminals of contactors for combined mounting of contactors and connection sets.For 3-pole contactors DimensionsTy pe Order codePkg qtyWeight(1 pce)hole Ø mmbar mmkgAF116 ... AF1466.513 x3LX1401SFN074210R100010.072AF190, AF2058.517.5 x 5LX2051SFN074810R100010.180AF265 ... AF37010.520 x 5LX3701SFN075410R100010.234AF400, AF46010.525 x 5LX4601SFN075710R100010.500AF580, AF7501340 x 6LX7501SFN076110R100010.850Connection socketsConnection socket can be used to replace built-in cable clamps in AF116 ... AF146.For contactorTy peOrder codePkgqtyWeight(1 pce)kg3-pole contactorsAF116 ... AF146LL146-301SFN074211R100060.102AF190 ... AF205LL205-301SFN074811R100010.166AF265 ... AF370LL370-301SFN075411R100010.173AF400 ... AF460LE4601SFN075716R100060.600AF580 ... AF750LE7501SFN076116R100060.7504-pole contactorsAF116 ... AF140LL146-401SFN074211R200080.132AF190 ... AF205LL205-401SFN074811R200020.216AF265 ... AF370LL370-401SFN075411R200020.224Connection moduleConnection module can be fixed on AF116 ... AF146 delivered with bar terminals.For contactorTy peOrder codePkgqtyWeight(1 pce)kg3-pole contactorsAF116 ... AF146LD146-301SFN074208R100020.1654-pole contactorsAF116 ... AF140LD146-401SFN074208R200020.2251SFC101050V0001LW140LW205-401SFC101049V0001LX1401SFC101073V0001LL146-301SFC101046V0001LD146-30LW205-403/260ABB MOTOR PROTECTION AND CONTROL1SFC101100C0201 - Rev. C03
—Terminal connecting strips and shorting barsParallel and series connection of 3-pole contactors:• To obtain a star point (3 parallel-connected poles)• To connect poles in parallel and thus increase the AC load passing through the flow path made up of the parallel-connected poles: LP, LY, LH, LF, LG. The relevant cable cross-sectional area may limit the maximum permissible current. Consult information in table below• To connect poles in series and thus increase the DC voltage controlled by the poles: LP, LY (only LY16-4 and LY38-4 secable strips).Ty pesfor connection of "n" poleswith terminalinsulatedLPn = 2nono (1)LYn = 2 (secable LY16-4, LY38-4 connecting strips)noyesn = 3noyes (1)LHn = 2yesnoLFn = 3yesyesLGn = 4yesyes(1) LP460 ... LP750, LY185 ... LY 750 not insulated. Use terminal shrouds.For contactorsmax. nominal continuous current with "n" polesCable cross-sectional areaTy pe Order codePkg qtyWeight(1 pce)in parallelin series2 poles 3 poles 4 poles 2 polesAmm²kgAF093033–256LY16-41SBN071303T1000100.006AF123236–27AF163440–30AF265060–4510LY38-41SBN072303T1000100.012AF116 ... AF146–240––LY1401SFN074203R100010.055AF190, AF205–400––LY1851SFN074703R100010.200AF265 ... AF370–670––LY3001SFN075103R100010.300AF400, AF460–1000––LY4601SFN075703R100010.450AF580, AF750–1650––LY7501SFN076103R100010.800AF190, AF205300–––LP1851SFN074712R100020.300AF265 ... AF370475–––LP3001SFN075112R100020.400AF400, AF460725–––LP4601SFN075712R100020.550AF580, AF7501200–––LP7501SFN076112R100020.950AF0945––10LH38-41SBN072304R100020.012AF1250––10AF1654––16AF2681––25AF30, AF3890––25AF0962–16LF16-41SBN071305R100020.020AF1270–25AF1675–25AF26112–35LF38-41SBN072305R100020.040AF30, AF38125–50AF09––70–25LG16-41SBN071306R100020.025AF12––78–25AF16––84–25LY16-41SBC100024V0014BACTy peFor contactorsDimensionsABCmminchmminchmminchLH38-4AF09 ... AF16111.204.38"833.27"220.87"AF26 ... AF381144.49"863.39"160.63"LF16-4AF09 ... AF161214.76"873.43"230.91"LF38-4AF26 ... AF38135.205.32"1034.06"311.22"LG16-4AF09 ... AF16124.204.89"873.43"230.91"LY1851SFC101088V00011SBC100035V0014LH38-41SBC100037V0014LF16-41SBC100036V0014LG16-4Main dimensions ABB MOTOR PROTECTION AND CONTROL 3/2611SBC101735S0201 - Rev. A03
—Connection accessories for starting solutionsConnecting links with manual motor startersThe BEA insulated 3-pole connecting links are used to connect AF09 ... AF65 contactors with the MS116 or MS132 or MS165 manual motor starters. The BEA insulated 3-pole connecting links ensure the electrical and mechanical connection between the contactor and the associated manual motor starter. BPR65-4 35 mm rail hooks used with BEA65-4 connecting link, allow direct mounting on 2 rails 35 mm of MS165 manual motor starters with AF40 ... AF65 contactors.For 3-pole contactors Manual motor starterTy pe Order codePkg qtyWeight(1 pce)kg AF09 ... AF16MS116-0.16 ... MS116-25,BEA16-41SBN081306T1000100.025MS132-0.16... MS132-25AF26 ... AF38MS116-0.16 ... MS116-16, BEA26-41SBN082306T1000100.025MS132-0.16 ... MS132-10MS116-20 ... MS116-32,BEA38-41SBN082306T2000100.030MS132-12 ... MS132-32AF40 ... AF65MS165-16 ... MS165-65BEA65-41SBN083406R100010.090MS165-16 ... MS165-65 (1)BPR65-4 (2)1SBN113405R100010.014Note : BEA not suitable for AF..Z contactors with DC control voltage 24 V DC (coil 30).(1) Applicable for MS165 manufactured after week 31, 2016 (date code > 16214).(2) Use one BPR65-4 for each contactor AF40 ... AF65.Connection sets for reversing contactorsThe BER and BEM connection sets are used to connect the main poles of two 3-pole contactors mounted side by side. The BER connection sets are made up of 1 upstream and 1 downstream con-nections. The BEM connection sets are made up of 3 upstream and 3 downstream connections. BER and BEM connection sets are insulated and made of solid copper bars.For 3-pole contactors Ty pe Order codePkg qtyWeight(1 pce)kgAF09 ... AF16BER16-41SBN081311R100010.045AF26 ... AF38BER38-41SBN082311R100010.100AF40 ... AF65BER65-41SBN083411R100010.175AF80, AF96BER96-41SBN083911R100010.250AF116 ... AF146BER140-41SFN084211R100010.615AF190, AF205BER205-41SFN084811R100011.237AF265 ... AF370BER370-41SFN085411R100012.140AF400, AF460BEM460-301SFN085701R100014.400AF580, AF750BEM750-301SFN086101R100017.300Phase to phase connectionsThe BEP and BES connection sets are used to connect phase to phase the main poles of two con-tactors mounted side by side. 4-pole contactors will then operate as source reversing contactors. The BEP connection sets are made up of 1 upstream or downstream connections. The BES connec-tion sets are made up of 3 upstream or downstream connections. BEP and BES connection sets are insulated and made of solid copper bars.For contactors Ty pe Order codePkg qtyWeight(1 pce)kg3-pole contactorsAF116 ... AF146BEP140-301SFN084214R100010.320AF190, AF205BEP205-301SFN084814R100010.534AF265 ... AF370BEP370-301SFN085414R100010.926AF400, AF460BES4601SFN085704R100012.200AF580, AF750BES7501SFN086104R100013.7004-pole contactorsAF116 ... AF140BEP140-401SFN084214R200010.420AF190 ... AF205BEP205-401SFN084814R200010.710AF265 ... AF370BEP370-401SFN085414R200011.230A1A2A1A2315534266412BEP, BES3-pole phase to phase con-nectionsA1A2A1A2315315426426BER, BEMReversing connections1SBC100014V0014BEA16-4BER16-41SBC100016V0014BEP140-301SFC101052V0001BEP4-pole changeover connectionsA1A2A1A23155374266487182E0743DBPR65-41SBC100078V00143/262ABB MOTOR PROTECTION AND CONTROL1SBC101736S0201 - Rev. D03
A1 A2 A1 A2 3 1 5 3 1 5 4 2 6 4 2 6 A1 A2 3 1 5 4 2 6A1 A2 A1 A2 3 1 5 3 1 5 4 2 6 4 2 6 A1 A2 3 1 5 4 2 6—Connection sets for star-delta starterThe BEY and BED connection sets are used to connect the main poles of the Line, Delta and Star contactors of a star-delta starter.The connection sets are made up of:• Line contactor / delta contactor: -BEY: upstream phase-to-phase connection -BED: upstream connection in parallel• Delta contactor / star contactor: downstream connection in parallel• Star contactor: star point upstream• Insulated, solid copper bar.For 3-pole line, delta & star contactors Interlock unit between delta & star contactorsTy pe Order codePkg qtyWeight(1 pce)kgAF09 ... AF16With or without VM4 or VEM4BEY16-41SBN081313R200010.050AF26 ... AF38With or without VM4 or VEM4BEY38-41SBN082713R200010.110AF40 ... AF65With or without VM96-4BEY65-41SBN083413R200010.200AF80, AF96With or without VM96-4BEY96-41SBN083913R200010.250AF116 ... AF146With or without VM19BEY140-41SFN084413R100011.040AF190 ... AF205 (line and delta)AF116 ... AF146 (star)With or without VM140/190BEY190-41SFN084813R100011.154AF190, AF205With or without VM19BEY205-41SFN085213R100011.205AF265 ... AF370 (line and delta)AF190 ... AF205 (star)With or without VM205/265BEY265-41SFN085413R100012.020AF265 ... AF370With or without VM19BEY370-41SFN085813R100012.110AF400 ... AF460With or without VM750HBED4601SFN085703R100014.700AF580 ... AF750 (line and delta)AF400 ... AF460 (star)With or without VM750HBED5801SFN085903R100016.300AF580 ... AF750With or without VM750HBED7501SFN086103R100017.700AF09 ... AF370Line-delta-star connectionAF400 ... AF750Star-delta-line connectionBEY16-41SBC100018V0014 ABB MOTOR PROTECTION AND CONTROL 3/2631SBC101737S0201 - Rev. A03
1SBC100452S0201 3/264ABB MOTOR PROTECTION AND CONTROL—Connection accessories for starting solutions- with Push-in Spring terminalsFor contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce)kgMechanical and electrical interlock set (1)AF09..K ... AF16..K0 2VEM4K1SBN030113R100010.034AF26..K ... AF38..KNote: - VEM4K includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4K electrical interlock block with A2 - A2 connection. - VE4K block must be used with A2-A2 connection to respect the electrical connection diagram.- VEM4K not suitable for AF..Z contactors with DC control voltage 12 ... 20 V DC (coil 20 and 24 V DC (coil 30).For product availability, please consult your ABB local sales organization.Connecting links with manual motor starters (1)AF09..K ... AF16..Kwith MS132-0.16K... MS132-25KBEA16-4K1SBN081321T1000100.051AF26..K ... AF38..Kwith MS132-0.16K... MS132-32KBEA38-4K1SBN082321T2000100.053(1)For product availability, please consult your ABB local sales organization.Note: BEA not suitable for AF..Z contactors with DC control voltage 24 V DC (coil 30).VEM4K1SBC100083V0014BEA16-4K1SBC100084V0014A2A201NC01NCKM1KM203
—Connection barsConnection between contactors/starters and moulded case circuit breakers. These connection sets are solid copper bars.For 3-pole contactors MCCBTy pe Order codePkg qtyWeight(1 pce)kgVertical assemblyAF116 ... AF146XT2BEA140/XT21SFN084206R100010.058AF116 ... AF146XT3BEA140/XT31SFN084206R100210.070AF116 ... AF146XT4BEA140/XT41SFN084206R100110.068AF190, AF205XT4BEA205/XT41SFN084806R100010.200AF190, AF205T4BEA205/T41SFN084806R100110.190AF265 ... AF370T5BEA370/T51SFN085406R100010.350AF400 ... AF750T6BEA750/T61SFN086106R100010.410AF400 ... AF750T5BEA750/T51SFN086106R100110.410Vertical assembly with control wire terminals (also suitable when using busbar kits for starter combinations)AF400 ... AF750T5BEA750D/T51SFN086106R100310.720AF400 ... AF750T6BEA750D/T61SFN086106R100210.720Horizontal assembly (also suitable when using busbar kits for starter combinations)AF400, AF460T4BEA460H/T41SFN085907R100012.450Connection bars between contactors and switch fuseConnection between contactors/starters and moulded case circuit breakers. These connection sets are solid copper bars.For 3-pole contactors Switch fuseTy pe Order codePkg qtyWeight(1 pce)kgVertical assemblyAF400, AF460OESA400BEF460/OESA4001SFN085708R100010.340AF460 ... AF750OESA630 to OESA800BEF750/OESA8001SFN086108R100010.740Horizontal assemblyAF400, AF460OESA400...LROESA460H/OESA4001SFN085709R100011.250Note: The BEF connection bars provided for the A145 ... A300 contactors can be used for the AF145 ... AF300 contactors.1SFC101061V0001BEA140/XT2 1SFC101064V0001BEA205/T4 1SFC101065V0001BEA370/T5 ABB MOTOR PROTECTION AND CONTROL 3/2651SFC101103C0201 Rev. B03
—Mounting platesMounting plates with fixing holes for the specified 3-pole contactors and overload relays.For 3-pole contactorsFor overload relaysType Order codePkg qtyWeight(1 pce)kgMounting plates for Direct on line startersAF400, AF460E500DUPN460-111SFN095705R100012.120AF580, AF750E800DUPN750-111SFN096105R100012.500For two contactors side by side with space for mechanical interlockFor one or two overload relaysType Order codePkg qtyWeight(1 pce)kgMounting plates for mechanical interlocked contactors, reversing starters and two speed starters for double windingsAF400, AF460E500DUPN460-211SFN095701R100013.490AF580, AF750E800DUPN750-211SFN096101R100014.230For main and delta contactorsFor star contactor (1)For overload relaysTy pe Order codePkg qtyWeight(1 pce)kgMounting plates for star-delta starters and two speed starters for single windingsAF400, AF460A300, AF400E500DUPN460-411SFN095703R100015.310AF580, AF750AF400 ... AF580E800DUPN750-411SFN096103R100016.320(1) Space for mechanical interlock included.1SFC101087V0001PN4603/266ABB MOTOR PROTECTION AND CONTROL1SFC101106C020103
—Adapter platesAdapter plates with fixing holes for replacing installed contactors.From contactorsTo contactorTy pe Order codePkg qtyWeight(1 pce)kgA95, AF95, A110, AF110 AF116, AF140, AF146PR146-11SFN094200R100010.300EH150, EH160, EH175, EH210, EG160AF190, AF205PR210-11SFN094900R100010.440EH250, EH260, EH300AF265, AF305, AF370PR300-11SFN095300R100010.560EH370, EH550, EG315AF400, AF460, AF580PR460-11SFN095700R100010.900EH700, EH800AF750PR750-11SFN096100R100010.500OKYM150, OKYM175AF190PR185-21SFN095100R100110.500OKYM200, OKYM250AF265, AF305, AF370PR300-21SFN095300R100110.500OKYM315AF400, AF460PR400-21SFN095700R100210.820OKYM400AF400, AF460PR460-21SFN095700R100110.800OKYM500AF580PR580-21SFN096100R100210.700EH550, EG630, OKYM630AF580, AF750PR750-21SFN096100R100111.1001SFC101048V0001PR146-1 E2119DhlL Dimensions (mm)Type of the plateDimensions Fixing holesLIhmmPR146-115090154 x ø 6.5PR210-120013211.54 x ø 7PR300-120017211.54 x ø 7PR460-127819811.54 x ø 7PR750-128324411.54 x ø 7PR185-220215211.24 x ø 11PR300-220215211.24 x ø 11PR400-227815111.54 x ø 11PR460-227817611.54 x ø 11PR580-228317611.54 x ø 11PR750-228325511.54 x ø 14Fixing holes according to the plate types ABB MOTOR PROTECTION AND CONTROL 3/2671SFC101107C020103
1SFC101077D0201AF116 ... AF1250AF116 ... AF1250RU19A1A2X3X4X1X2For direct opening of AF400 ... AF1250 contactors, connect through built in PLC interface.Control inputs—Low Voltage Ride Through (LVRT) modulesRU19 is designed to meet the Low Voltage Ride Through (LVRT) requirements for grid connections by staying operational during voltage dips preventing disturbances on the grid it self.The RU19 is a separate module connected to the contactors coil connection A1-A2 creating a delay function of the opening of the contactor. When controlled by PLC, the contactor is operated di-rectly whitout delay functionality. The RU19 can be screw or DIN rail mounted.For contactorRated control circuitvoltage UcType Order codeWeightPkg(1 pce)V 50/60 HzkgAF116 ... AF370 use coil 33110...120RU19/1201SFN170801R10010.400AF400 ... AF1250 use coil 69AF116 ... AF370 use coil 33230...240RU19/2401SFN170801R10020.400AF400 ... AF1250 use coil 70171 6.73"DIN-railmountingM5 screw (not provided) 5 Nm49 1.93"RU19/240RU19/1201SFC101223V0001Main dimensions mm, inches3/268ABB MOTOR PROTECTION AND CONTROL03
—Contactor coils, main contact sets and arc chutesContactor coilsFor contactors Rated control circuit voltageUc min. ... Uc max.Ty pe Order codePkg qtyWeight(1 pce)V 50/60 HzV DCkgAF400, AF460-24...60ZAF4601SFN155770R680610.52548...13048...130ZAF4601SFN155770R690610.525100...250100...250ZAF4601SFN155770R700610.525250...500250...500ZAF4601SFN155770R710610.525AF580 ... AF1250-24...60ZAF7501SFN156170R680611.33548...13048...130ZAF7501SFN156170R690611.335100...250100...250ZAF7501SFN156170R700611.335250...500250...500ZAF7501SFN156170R710611.335AF1350 ... AF2050100...250100...250ZAF1650 (1)1SFN156570R70261 set0.900ZP1650 (2)1SFN166521R107010.300AF2650100...250100...250ZAF2650 (1)1SFN156670R70261 set0.900ZP2650 (2)1SFN166621R107010.300ZAF460, ZAF750 : printed circuit board included.(1) One set of two coil.(2) Printed circuit board.Main contact setsThe contact sets for 3-pole contactors consists of six fixed contacts, three moving contacts, springs and the required screws.For 3-pole contactorsTy pe Order codePkg qtyWeight(1 pce)kgAF400ZL4001SFN165703R100011.320AF460ZL4601SFN165903R100011.320AF580ZL5801SFN166103R100011.840AF750ZL7501SFN166303R100011.840AF1250ZL12501SFN166403R100011.840AF1350For contactors produced before 2014-01-13, with serial number before 1S16010051403xxxxZL13501SFN166503R100012 500For contactors produced since 2014-01-13, with serial number above 1S16010051403xxxxZL1350-11SFN166503R100114 500AF1650For contactors produced before 2014-01-13, with serial number before 1S16010051403xxxxZL16501SFN166703R100013 500For contactors produced since 2014-01-13, with serial number above 1S16010051403xxxxZL1650-11SFN166703R100114 500AF2050For contactors produced before 2014-01-13, with serial number before 1S16010051403xxxxZL20501SFN167003R100013 500For contactors produced since 2014-01-13, with serial number above 1S16010051403xxxxZL2050-11SFN167003R100114 500AF2650 (3)ZL26501SFN166603R100011.200(3) Does not include fixed contacts and screws.—Arc chutesFor contactorsTy pe Order codePkg qtyWeight(1 pce)kgAF400, AF460ZW4601SFN165710R100011.380AF580, AF750, AF1250ZW7501SFN166110R100011.500AF1350, AF1650, AF2050ZW16501SFN166510R100114.560AF2650ZW26501SFN166610R100014.0001SFC101007F0201ZAF16501SFC101009F0201ZL1650 ABB MOTOR PROTECTION AND CONTROL 3/2691SFC101137C0201 - Rev. D03
—Accessories for UA, UA..RA contactors and GA75, GAE75, GAF contactors3/272 Auxiliary contact blocks3/278 Electronic timers3/282 Mechanical and electrical interlock units3/284 CA5, CE5, CAL, CEL18 and TEF5 fitting details3/285 Function markers - Mounting piece3/286 Surge suppressors for contactor coils3/288 Interface relays3/290 Mechanical latching units3/292 Additional terminal blocks and others accessories3/293 Terminals for control lead connections3/294 Connection bar for contactors3/295 Contactor coils and main contact sets3/404 Voltage code table— For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310ABB MOTOR PROTECTION AND CONTROL 3/27103
—Auxiliary contact blocksThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:•CA5 1 or 4-pole block, instantaneous with N.O., N.C. contacts•CC5 1-pole block, with N.O. leading contact or N.C. lagging contact.Select the 4-pole auxiliary contact blocks CA5 type, according to the contactor type for compliance with the standard requirements (see "Terminal Marking and Positioning").Types of auxiliary contact blocks for side mounting:•CAL 2-pole block instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgFront-mounted instantaneous auxiliary contact blocks, 1-poleUA16 ... UA1101 0– –CA5-101SBN010010R1010100.0140 1– –CA5-011SBN010010R1001100.014– –1 0CC5-101SBN010011R1010100.014– –0 1CC5-011SBN010011R1001100.014Front-mounted instantaneous auxiliary contact blocks, 4-poleUA16 ... UA302 2– –CA5-22M1SBN010040R112220.0603 1– –CA5-31M1SBN010040R113120.0601 3– –CA5-13M1SBN010040R111320.0600 4– –CA5-04M1SBN010040R110420.0601 11 1CA5-11/11M1SBN010040R111820.060UA50 ... UA1102 2– –CA5-22E1SBN010040R102220.0603 1– –CA5-31E1SBN010040R103120.0604 0– –CA5-40E1SBN010040R104020.0600 4– –CA5-04E1SBN010040R100420.0601 11 1CA5-11/11E1SBN010040R101820.060Side-mounted instantaneous auxiliary contact blocks, 2-poleUA16 ... UA751 1– –CAL5-111SBN010020R101120.050UA95, UA110, GAF185...GAF20501 1– –CAL18-111SFN010720R101120.050For each contactor type, refer to "Accessory fitting details" table.Note: -The front-mounted auxiliary contact blocks provided for the UA75 contactors can be used with the GA and GAE types -The CAL auxiliary contact blocks can be used with GA contactors: GA75-10-00: 2 x CAL5-11 blocks GA75-10-11: 1 x CAL5-11 block GAE75-10-00: 1 x CAL5-11 block GAE75-10-11: no add-on block. -The CAL auxiliary contact blocks can be used with UA..RA contactors. See "Accessory fitting details" for this contactor type.1SBC580992F0301CA5-101SBC573794F0302CA5-40E1SBC573752F0301CAL5-111SFC101033F0201CAL18-113/272ABB MOTOR PROTECTION AND CONTROL1SBC101520S0201 - Rev. B03
1SBC101522S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/273—Auxiliary contact blocks Technical dataFront mountedSide mountedTy pes1-pole CA5, 1-pole CC5, 4-pole CA5CAL5-11CAL18-11, CAL18-11BContact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated operational voltage Ue max.24...690 V ACConventional thermal current Ith - θ ≤ 40 °C16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A380-440 V 50/60 Hz 3 A500-690 V 50/60 Hz 2 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.3 A / 66 W250 V DC 0.3 A / 75 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacityA40 ... A75 contactors17 V / 1 mA–with failure rate acc. to IEC 60947-5-4≤ 10-7–A95 ... A110 contactors24 V / 50 mA–24 V / 50 mA (0.5 million of operating cycles)with failure rate acc. to IEC 60947-5-4––≤ 10-6Power dissipation per pole at 6 A0.1 W0.15 WMechanical durabilityNumber of operating cycles10 millions (UA16 ... UA75)10 millions5 millions (UA95 ... UA110)3 millions (UA95 ... UA110)3 millions (GAF185 ... GAF750)0.5 million (GAF1250 ... GAF2050)Max. switching frequency3600 cycles/hElectrical durabilityNumber of operating cyclessee "Electrical durability" curvesMax. switching frequencyAC-151200 cycles/hDC-13900 cycles/hContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL ≤ 7.7 mm8 mml >3.7 mm3.7 mmTightening torque1 NmDegree of protection TerminalsIP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
1SBC101577S0201 - Rev. C3/2 74ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for severe industrial environmentsThe auxiliary contact blocks are used for the operation of auxiliary and control circuits for severe industrial environments.Types of auxiliary contact blocks for front mounting:•CE5 1-pole block, instantaneous with N.O. contact or N.C. contact, designed in 2 protection versions: -CE5-.. D with built-in microswitch IP40, degree of protection (IP20 on terminals) -CE5-.. W with built-in microswitch IP67, degree of protection (IP20 on terminals).Types of auxiliary contact blocks for side mounting:•CEL18 1-pole block with built-in microswitch IP67 degree of protection (IP20 on terminals). Instantaneous N.O. or N.C. contact.For clipping onto the right- and/or left-hand side of the contactors.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.For contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgFront-mounting instantaneous auxiliary contact blocks, 1-poleUA16 ... UA751–– –CE5-10D0.11SBN010015R101010.020–1– –CE5-01D0.11SBN010015R100110.0201–– –CE5-10D21SBN010017R101010.020–1– –CE5-01D21SBN010017R100110.0201–– –CE5-10W0.11SBN010016R101010.020–1– –CE5-01W0.11SBN010016R100110.0201–– –CE5-10W21SBN010018R101010.020–1– –CE5-01W21SBN010018R100110.020Side-mounting instantaneous auxiliary contact blocks, 1-pole microswitch auxiliary contact N.O. or N.C.UA95, UA110GAF185 ... GAF20501 0– –CEL18-101SFN010716R101010.050UA95, UA110GAF185 ... GAF20500 1– –CEL18-011SFN010716R100110.050For each contactor type, refer to "Accessory fitting details" table.Note: The front-mounted auxiliary contact blocks provided for the UA contactors can be used with the GA and GAE types. The side-mounted auxiliary contact blocks provided for the UA95, UA110 contactors can be used with the GAF types.1SBC581011F0301CE5-01W03
1SBC101584S0201ABB MOTOR PROTECTION AND CONTROL 3/275—Auxiliary contact blocks Technical dataFront-mountedSide-mountedTy pes1-pole CE5-..0.11-pole CE5-..2CEL18-10, CEL18-01Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1250 VRated operational voltage Ue max.125 V250 V125 VConventional thermal current Ith - θ ≤ 40 °C0.1 A2 A0.1 AIe / Rated operational currentAC-14AC-15AC-14acc. to IEC 60947-5-124-127 V 50/60 Hz 0.1 A2 A0.1 A220-240 V 50/60 Hz–2 A–Making capacity acc. to IEC 60947-5-16 x Ie AC-1410 x Ie AC-156 x Ie AC-14Breaking capacity acc. to IEC 60947-5-16 x Ie AC-1410 x Ie AC-156 x Ie AC-14Ie / Rated operational current DC-12acc. to IEC 60947-5-124 V DC 0.1 A2 A0.1 A48 V DC 0.1 A1 A0.1 A72 V DC 0.1 A0.3 A0.1 A110 V DC 0.1 A0.2 A0.1 A125 V DC–0.2 A–220 V DC–0.1 A–Short-circuit protection device0.1 A (FF type fuses) (1)10 A (FF type fuses) (1)0.1 A (FF type fuses) (1)Minimum switching capacityA40 ... A75 contactors3 V / 1 mA17 V / 1 mA3 V / 1 mAWith failure rate acc. to IEC 60947-5-4–≤ 10-7–A95 ... A110 contactors3 V / 1 mA17 V / 1 mA–With failure rate acc. to IEC 60947-5-4–≤ 10-7–Mechanical durabilityNumber of operating cycles5 millions for CE5-..D0.15 millions for CE5-..D21 million2.5 millions for CE5-..W0.12.5 millions for CE5-..W2–Max. switching frequency3600 cycles/h1200 cycles/hElectrical durabilityNumber of operating cycles2.5 millions for CE5-..D0.11 million for CE5-..D20.7 millions0.7 millions for CE5-..W0.10.3 millions for CE5-..W2Max. switching frequencyAC-14, AC-151200 cycles/hDC-12900 cycles/hContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage125 V AC / 110 V DC250 V AC / 220 V DC125 VPilot dutyAC thermal rated current0.1 A2 A0.1 AConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlBars or lugsL ≤ 7.7 mml >3.7 mmConnection capacity acc. to UL/CSA1 or 2 x AWG 18...14Tightening torque1 NmDegree of protection TerminalsIP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529MicroswitchesIP40 for CE5-..D0.1IP40 for CE5-..D2IP67IP67 for CE5-..W0.1IP67 for CE5-..W2Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2(1) or HRC fuses for very fast action (6.3 x 32 mm size).03
1SBC100238S0201 - Rev. A3/276ABB MOTOR PROTECTION AND CONTROL—Auxiliary contactsElectrical durabilityElectrical durability for AC-15 utilization categoryAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:•making current: 10 x Ie with cos φ = 0.7 and Ue•breaking current: Ie with cos φ = 0.4 and Ue.These curves represent the electrical durability of the built-in or add-on auxiliary contacts, in relation to the breaking current.The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.•1-pole and 4-pole CA5,1-pole CC5,2-pole CAL5 and CAL18 add-on auxiliary contacts.Example:Breaking current = 1.2 AOn the opposite curve at intersection "O" 1.2 A the corresponding value for the electrical durability is approximately 2.7.106 operating cycles.Breaking current (A)0.020.050.10.30.51245100.10.20.30.51235102030Million operating cycles360.21.22.7Electrical durability for DC-13 utilization categoryDC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current = Ie with Ue value.•1-pole and 4-pole CA5,1-pole CC5,2-pole CAL5 and CAL18 add-on auxiliary contacts.Example:Control of DC electro-magnet: Ue voltage = 72 V DC and breaking power = 70 W.On the opposite curve at intersection "O" 72 V / 70 W the corresponding value for the electrical durability is approximately 2.106 operating cycles.Voltage (V)Breaking power (W)101105205021007020 2425010020050050721.10 cycles63.10 cycles610.10 cycles603
1SBC101586S0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/2772122111241423132NCNCNCNCCA5-04E2122131443443132NONCNCNOCA5-22E2122131443443334NONCNONOCA5-31E2122131447483536NONCNCNOCA5-11/11E1314232433344344NONONONOCA5-40E-1-2NCCA5-01-5-6NCCC5-01-7-8NOCC5-10-3-4NOCE5-10, CEL18-10-1-2NCCE5-01, CEL18-01-3-4NOCA5-101-pole auxiliary contacts21X /22X /13X /14X /NONC43X44X31X32XCAL5-11, CAL18-11(Left-side mounted)25X /26X /17X /18X /NONC47X48X35X36XCCL5-11 (Left-side mounted)NCNO47X /48X /35X /36X /25X26X17X18XCCL5-11 (Right-side mounted)NCNO43X /44X /31X /32X /21X22X13X14XCAL5-11, CAL18-11 (Right-side mounted)2-pole auxiliary contacts4-pole auxiliary contacts—Add-on auxiliary contactsTerminal marking and positioning033132212251524142NCNCNCNCCA5-04M2122333443445354NONONONCCA5-31M2122313243445354NO NONCNCCA5-22M31324142NCNC5354NO2122NCCA5-13M3334212257584546NC NONONCCA5-11/11M
1SBC101675S0201 - Rev. B3/278ABB MOTOR PROTECTION AND CONTROLTEF5-OFF—Electronic timersTEF5 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFF-delay versions.Compact solution in cabinet compared to separate timersTEF5 electronic timers are front-mounted and locked on contactors. A mechanical indicator allows to show the state of the contactor.TEF5 electronic timers are supplied by direct wiring to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil.Available for a wide control voltage range 24...240 V AC/DCTEF5-ON or TEF5-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, indepen-dently of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted by means of a rotary switch. The timing function is activated by closing or open-ing the device on which the timer is mounted. The OFF-delay version operates without additional control supply.For contactors,contactor relaysTime delay rangeselected by switchDelaytypeRated control circuit voltage UcAuxiliary contactsTy pe Order codeWeightPkg(1 pce)V 50/60 Hz or DCkgUA16 ... UA75GA75, GAE750.1...1 s1...10 s10...100 sON-delay24...2401 1TEF5-ON1SBN020312R10000.065OFF-delay24...2401 1TEF5-OFF1SBN020314R10000.0651SBC101396F001403
1SBC101674S0201 - Rev. AABB MOTOR PROTECTION AND CONTROL 3/279—Electronic timersTechnical dataContact utilization characteristics according to IECTy pesTEF5-ONTEF5-OFFStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Uiacc. to IEC 60947-5-1400 VRated impulse withstand voltage Uimp4 kVRated operational voltage Ue max.240 VRated frequency (without derating)50 / 60 HzConventional thermal current Ith - θ ≤ 40 °C5 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 3 A220-240 V 50/60 Hz 1.5 AMaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 1 A / 24 WShort-circuit protection device gG type fuse6 ARated short-time withstand current Icwfor 1.0 s8 Aθ = 40 °Cfor 0.1 s8 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-424 V DC 10-7Power dissipation per pole at 3 A0.1 WFunction diagramON-delayOFF-delayUc (A1 - A2)N.O. (67 - 68)t100 msmin.150 msmin.N.C. (55 - 56)Uc (A1 - A2)N.O. (67 - 68)t100 msmin.1 smin.N.C. (55 - 56)Bistable relay inside. Before use, once apply Uc then switch it off in order to initialize position of the contacts.Control circuit voltage AC control voltageRated control circuit voltage Uc24...240 V AC50/60 HzAverage consumption1.5 mA RMS1 mA RMSDC control voltageRated control circuit voltage Uc24...240 V DCAverage consumption1.5 mA1 mARated frequency limits50 / 60 HzSupply voltage range0.85...1.1 x Uc (at θ ≤ 70 °C)Overvoltage protectionVaristor includedTime delay range (t) selected by switch0.1...1 s1...10 s10...100 sOn-load reiteration accuracy under constant conditions≤ 1 %Minimum ON period0.1 s1 sRecovery time0.15 s0.1 sAmbient air temperature Operation-25 °C ... +70 °CStorage-40 °C ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude2000 mMounting positionsAcc. to mounting positions permitted on contactors or contactor relaysShock withstand1/2 sinusoidal shock for 11 ms: no change in contact positionacc. to IEC 60068-2-27 and EN 60068-2-27Same as contactor or contactor relay(Mounting position 1)Mechanical durabilityNumber of operating cycles5 millions operating cyclesMax. switching frequency3600 cycles/h1800 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/h03
1SBC101674S0201 - Rev. A3/280ABB MOTOR PROTECTION AND CONTROL—Electronic timersTechnical dataConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...2.5 mm²2 x 1...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlLugsL ≤ 8 mml >3.7 mmStripping length10 mmTightening torque1 N.m / 9 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals should be tightenedAll terminalsM3.5 Screwdriver typeFlat Ø 5.5 / Pozidriv 2Terminal MarkingA1A256 NC68 NO55 NC67 NOKM1A1A256 NC68 NO55 NC67 NOKM103
ABB MOTOR PROTECTION AND CONTROL 3/28103—Notes
—Mechanical and electrical interlock unitsWhen mounted between two contactors, the mechanical interlock unit prevents one of the con-tactors from closing as long as the other contactor is closed.VE interlock units are used for mechanical and electrical interlocking of two AC or DC operated contactors mounted side by side.For contactors MountingTy pe Order codePkg qtyWeight(1 pce)kgMechanical and electrical interlock units for two horizontal mounted contactors GA75, GAE75Rail mountingVE5-21SBN030210R100010.1461SBC101429F0014VE5-23/282ABB MOTOR PROTECTION AND CONTROL1SBC101525S0201 - Rev. B03
1SBC101331S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/283—Mechanical and electrical interlock unitsTechnical dataTy pesVE5-2Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated operational voltage Ue max.24...690 VConventional thermal current Ith - θ ≤ 40 °C16 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A380-440 V 50/60 Hz 3 A500-690 V 50/60 Hz 2 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A 48 V DC 2.8 A 72 V DC 1 A 125 V DC 0.55 A250 V DC 0.3 AShort-circuit protection device - gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 APower dissipation per pole at 6 A0.15 WMechanical durabilityNumber of operating cycles5 millions operating cyclesMax. switching frequency600 cycles/hUtilization characteristics according to UL/CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 VConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL <8 mml >3.5 mmTightening torqueRecommended1 NmMax.1.2 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsdelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Terminal marking0102NCE0085D10102NCTechnical note: when, during switching, the arc time is estimated to more than 40 ms, the closing signal of one of the two contactors must be delayed with respect to the open-ing signal of the other contactor in order to prevent a short-circuit. Use a TEF5 electronic timer according to application use with time lapse for GA75, GAE75 contators.03
1SBC101585S0201 - Rev. A3/284ABB MOTOR PROTECTION AND CONTROL—CA5, CE5, CAL, CEL18 and TEF5 fitting detailsMany configurations are possible depending on whether these are front-mounted or side-mounted.ContactortypesMainpolesBuilt-inauxiliarycontactsFront-mounted accessoriesElectronic timerSide-mounted accessoriesAuxiliary contact blocksAuxiliary contact blocksInterlock unit1-pole CA5 1-pole CE54-pole CA5TEF52-pole CAL 1-pole CEL18VE5UA contactorsUA16 ... UA263 0 1 01 to 4 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 to 2 x CAL5-11 –1 to 2 x CE5 max. (1)+ 1 x 1-pole CA5 or CE5 (1)+ 1 x 1-pole CA5 ––UA303 0 1 01 to 5 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 to 2 x CAL5-11 –1 to 3 x CE5 max. (1)+ 1 x 1-pole CA5 or CE5 (1)+ 1 x 1-pole CA5 ––UA50 ... UA753 0 0 01 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 to 2 x CAL5-11 –1 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (1)+ 2 x 1-pole CA5 ––3 0 1 11 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 x CAL5-11 –1 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (1)+ 2 x 1-pole CA5 ––UA95, UA1103 0 0 01 to 6 x CA5 or 1 x 4-pole CA5–+ 1 to 2 x CAL18-11–1 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (1)–or 1 to 2 x CEL18–3 0 1 11 to 6 x CA5 or 1 x 4-pole CA5–+ 1 x CAL18-11–1 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (1)–or 1 x CEL18–UA..RA contactorsUA16-30-10RA3 0 1 0–––+ 1 x CAL5-11 –UA26-30-10RA3 0 1 0UA30-30-10RA3 0 1 01 x CA5––+ 1 to 2 x CAL5-11 –1 x CE5UA50-30-00RA3 0 0 01 to 2 x CA51 to 2 x CE5––+ 1 to 2 x CAL5-11 –UA63-30-00RA3 0 0 0UA75-30-00RA3 0 0 0UA95-30-00RA3 0 0 01 to 2 x CA5––+ 1 to 2 x CAL18-11 –UA110-30-00RA3 0 0 01 to 2 x CE5––or 1 to 2 x CEL18–GA75, GAE75 contactorsGA751 0 0 01 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 to 2 x CAL5-11or 1 x VE5-21 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (2)+ 2 x 1-pole CA5–+ 1 x CAL5-111 0 1 11 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 x CAL5-11or 1 x VE5-21 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (2)+ 2 x 1-pole CA5––GAE751 0 0 01 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5+ 1 x CAL5-11or 1 x VE5-21 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (2)+ 2 x 1-pole CA5––1 0 1 11 to 6 x CA5 or 1 x 4-pole CA5or 1 x TEF5––1 to 5 x CE5 max. (2)+ 2 x 1-pole CA5 or CE5 (2)+ 2 x 1-pole CA5––Notes regarding combination of CE5 with other accessories:(1) The total number of N.O. or N.C. CE5 and other additional N.C. CA5 auxiliary contacts is limited to 3. CES auxiliary contacts not allowed in mounting position 5.(2) The total number of N.O. or N.C. CE5 and other additional N.C. CA5 auxiliary contacts is limited to 5.03
—Function markersMounting pieceBA5-50 Function markersSet of 50 function markers designed to be clipped onto the front face of devices. Details can be added to these markers using a ball point pen, indelible felt-tip pen or pentel white.Self-adhesive labels (not supplied) can also be added to them.Marker dimensions: 7 x 19 mm (0.276" x 0.748").For contactorsTy pe Order codePkg qtyWeight(1 pce)kgUA, UA..RA and accessoriesGA75, GAE75BA5-501SBN110000R100010.017BP16 Mounting pieceMounting piece for screw fixing (M4, not supplied) of UA, UA..RA series contactors indicated in the table below.Easy handling of screwdrivers and screw driving.Add-on mounting piece on contactor's rear face, offering a wide fixing facility.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgUA16, UA16..RABP161SBN111403R10001000.141BA5-50BP161SBC586724F03021SBC575874F030135 1.38"84 3.31"4.5 0.18"4.5 0.18"ø 4.5 0.18"M4 8-32 UNCDrilling plan for UA16, UA16..RA contac-tors with BP16 ABB MOTOR PROTECTION AND CONTROL 3/2851SBC101531S0201 - Rev. B03
—Surge suppressors for contactor coils01000100 (V)T (μs)01000100A 884DRV5/50RC5-1/501SBC573891F03011SBC574001F0301The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to breakdown of in-sulators and even destruction of certain sensitive components. The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of 3500 V.Overvoltage Factor The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil rated control voltage Uc:Ûs max. Ûs max. Ûs max.k = in DC: k = or in AC: k = Ûc Uc Uc√23500For example the following is obtained for the above graph: k =≈ 6042 √2To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppres-sors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies.Each case is different, but the technical data tolerances and the generous sizing of parts have en-abled us to reduce the number of variants.We have chosen the following solutions: transil diodes, varistors and RC blocks. Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.For contactors Rated control circuit voltage UcType Order codePkg qtyWeight(1 pce)VACDCkgUA, UA..RAGA75, GAE7524...50●●RV5/501SBN050010R100020.01550...133●●RV5/1331SBN050010R100120.015110...250●●RV5/2501SBN050010R100220.015250...440●●RV5/4401SBN050010R100320.015UA, UA..RAGA7524...50●–RC5-2/501SBN050200R100020.01550...133●–RC5-2/1331SBN050200R100120.015110...250●–RC5-2/2501SBN050200R100220.015250...440●–RC5-2/4401SBN050200R100320.015GAE7512...32–●RT5/321SBN050020R100020.01525...65–●RT5/651SBN050020R100120.01550...90–●RT5/901SBN050020R100220.01577...150–●RT5/1501SBN050020R100320.015150...264–●RT5/2641SBN050020R100420.0153/286ABB MOTOR PROTECTION AND CONTROL1SBC101527S0201 - Rev. B03
1SBC101335S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/287—Surge suppressors for contactor coilsTechnical dataVaristorRV5/50RV5/133RV5/250RV5/4 4 0Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V AC24...50 V DC50...133 V DC110...250 V DC250...440 V DCResidual overvoltage (clipping voltage)132 V AC 270 V AC480 V AC825 V AC132 V DC 270 V DC480 V DC825 V DCOpening time growth factor1.1...1.5Operating temperature-20...+70 °CConnection to the coil terminals (parallel mounting)Clip-on for both fixing and connection.FixingClipped onto the top part of the contactor base without change in contactor overall dimensions.AdvantagesHigh energy absorption: good damping - Unpolarized system.DrawbackClipping as from Uvdr*, thus voltage front up to this point.*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %.RC typeRC5-2/50RC5-2/133RC5-2/250RC5-2/440Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V ACResidual overvoltage (clipping voltage)2 to 3 x Uc max.Opening time growth factor1.2...1.3Operating temperature-20...+70 °CConnection to the coil terminals (parallel mounting)Clip-on for both fixing and connection.FixingClipped onto the top part of the contactor base without change in contactor overall dimensions.AdvantagesVery fast clipping - Attenuation of steep fronts and thus of high frequencies. No operating delays.Transil diodeRT5/32RT5/65RT5/90RT5/150RT5/264Rated control circuit voltage Uc12...32 V DC25...65 V DC50...90 V DC77...150 V DC150...264 V DCResidual overvoltage (clipping voltage)50 V DC100 V DC150 V DC210 V DC390 V DCOpening time growth factor1.5...3Operating temperature-20...+70 °CConnection to the coil terminals (parallel mounting)Clip-on for both fixing and connection.FixingClipped onto the top part of the contactor base without change in contactor overall dimensions.AdvantagesGood energy absorption - Unpolarized system - Simple, reliable system.DrawbackA certain delay on drop out which does not however reduce contactor breaking capacity.Wiring diagramsA1A2E0733DA1A2E0735DA1A2E0734DTransil diodeVaristorRC typeDimensionsE0844DRV5, RC5, RT5The add-on block does not increase thecontactor overall dimensions03
—Interface relaysRA5-1 interface relay is designed to receive 24 V DC signals delivered by PLC’s or other sources with a low output power and to restore them with sufficient power to operate the coils of the relevant contactors.RA5-1 interface relay is made up of a miniature electromechanical relay equipped with a N.O. contact and with a low consumption 24 V DC coil.The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power contactor.Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators and, more generally, on component lifetime. The RA5-1 is equipped with surge suppressors:•on the 24 V DC relay coil via a diode,•on the power contactor coil via a varistor.Furthermore, the RA5-1 is protected against relay pole reversal by a diode inserted between the E1 and E2 input terminals.For contactorsCoil voltagesRated control circuit voltage UcType Order codePkg qtyWeight(1 pce)V 50/60 HzV DCkgUA, UA..RAGA7524...25024RA5-11SBN060300R100010.050RA5-11SBN060300T1000100.0501SBC101005F0014RA5-13/288ABB MOTOR PROTECTION AND CONTROL1SBC101528S0201 - Rev. B03
1SBC101337S0201 Rev. AABB MOTOR PROTECTION AND CONTROL 3/289—Interface relaysTechnical dataTy peRA5-1Utilization characteristics according to IECStandardsIEC 60255-5Rated insulation voltage Ui acc. to IEC 60947-4-1250 V ACAmbient air temperature In free air operationat Uc = 24 V DC (between E1 and E2) -25...+70 °Cfrom 0.85 to 1.1 x Uc -25...+55 °CStorage-40...+70 °CClimatic withstandComplies with that of associated contactorsMaximum operating altitude3000 mMounting positionsNo limitationFixingUsing the contactor A1 and A2 teminal connecting partsConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL <8 mml >3.5 mmTightening torqueRecommended1 NmMax.1.2 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Protection against direct contact in acc. with EN 50274RA5-1 wired and mounted on the associated contactorScrew terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 2Working dataSurge suppressionFor contactor coilVaristorFor interface relay coilDiodeProtection against polarity reversal between terminals E1 and E2DiodeInterface relay operating timeClosing and drop-out ≤ 10 msTotal operating time, interface relay + contactorBetween energization and:N.O. contact closing20...37 msN.C. contact opening17...32 msBetween de-energization and:N.O. contact opening17...25 msN.C. contact closing20...28 msElectrical input dataControl voltage (E1 and E2 terminals) UcRated value24 V DCMax. range at ambient temperature 20 °C19...30 V DCMax. consumption for Uc = 24 V DC, θ = 20 °C0.3 W"0" status (relay open)for Uc≤ 2.4 V DCfor Ic< 1 mA"1" status (relay closed) for Uc≥ 19 V DCMax. short supply interruption immunity time2 msElectrical output dataSwitching voltage (A0 and A2 terminals)≤ 250 V ACElectrical durabilityNumber of operating cycles2 millions (600 cycles/h) on UA16(RA) ... UA75(RA), GA75, GAE75 contactors0.5 million (600 cycles/h) on UA95(RA) and UA110(RA) contactorsConnectionUc ≤ 250 V AC24 V DC+–RA 5-1A0E2 –E1 +KM1A1A2PLCOutputA2E0742DGThe "E1+" and "E2-" input terminals must be connected, according to their polarity, to the PLC output.The RA5-1 is equipped with two terminal pads for connection to the A1 and the A2 terminals of the contactor coil. This coil is supplied between the A0 and the A2 terminals of the RA 5-1.Mounting: terminals pads clamped inside the contactor coil terminals.03
—Mechanical latching unitsFor converting standard contactors into latched contactors.The WB75-A block contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching.Captive screw type connecting terminals, built-in cable clamps, M3.5 (+,-) pozidriv 2 screw with screwdriver guidance; delivered untightened and protected against accidental direct contact.Operation After closing, the contactor continues to be held in the closed position by the latching mechanism should the supply voltage fail at the contactor coil terminals.Contactor opening can be controlled:•electrically by an impulse (AC or DC) on the WB75-A block coil. (the coil is not designed to be permanently energized)•manually by pressing the pushbutton on the front face of the WB75-A block.Mounting The WB75-A block is clipped onto the front face of the 1-stack contactor where it takes up two slots. The two other slots may accept CA5... single pole auxiliary contacts (1 block on each side of the mechanical latch).For contactorsRated control circuit voltage UcType Order codePkg qtyWeight(1 pce)V 50 Hz or DC V 60 HzkgUA16 ... UA75,GA75, GAE752424...28WB75-AFPTN372726R100110.1204242...48WB75-AFPTN372726R100210.1204848...55WB75-AFPTN372726R100310.120110110...127WB75-AFPTN372726R100410.120220...230220...255WB75-AFPTN372726R100610.120230...240230...277WB75-AFPTN372726R100510.120380...415380...440WB75-AFPTN372726R100710.120415...440440...480WB75-AFPTN372726R100810.1201SBC565483F0301 WB75-AE2676DE1 E2Terminal marking3/290ABB MOTOR PROTECTION AND CONTROL1SBC101526S0201 - Rev. B03
1SBC101333S0201 ABB MOTOR PROTECTION AND CONTROL 3/291—Mechanical latching unitsTechnical dataTy peWB75-A Utilization characteristics according to IECRated insulation voltage Ui acc. to IEC 60947-1690 VMax. electrical impulse timeOn AC coil (with load factor 5 %)20 sOn DC coil (with load factor 3 %)8 sMin. electrical impulse timeFor latching (energizing of the contactor coil)AC50 ms (UA, GA contactors)DC50 ms (GAE contactors)For pull-out (energizing of the WB block coil)AC30 ms (UA, GA contactors)DC50 ms (GAE contactors)Coil operating limitsAC or DC supply 0.85...1.1 x UcAC control voltage 50/60 HzRated control circuit voltage Uc24...480 V ACCoil consumptionAverage pull-in value90 VAAverage holding value60 VADC control voltageRated control circuit voltage Uc24...440 V DCCoil consumptionAverage pull-in value110 WAverage holding value110 WOn contactor closing (latching)Between coil energization and:N.O. contact closingNo difference with the operation of a contactor without mechanical latching unitN.C. contact openingNo difference with the operation of a contactor without mechanical latching unitOn contactor opening (unlatching)Between WB coil energization and:N.O. contact opening5...25 msN.C. contact closing7...28 msMechanical durabilityNumber of operating cycles1 million operating cyclesMax. switching frequency3600 cycles/h with on-load factor of 8 %Connecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 1...4 mm²2 x 1...4 mm²Flexible with ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²LlLugsL <8 mml >3.5 mmTightening torqueRecommended1 NmMax.1.2 NmScrew terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typeFlat Ø 5.5 / Pozidriv 203
—Additional terminal blocks and other accessoriesTerminal blocksThe LD terminal blocks are designed to increase the connecting capacity of the contactor on which they are fitted and for preparation of the wiring before final connection on the contactor.The LD blocks are 3-pole terminal blocks with tunnel terminals.The LD75 terminal blocks are fixed in the 3 independent slots located above the built-in connectors.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgUA50(RA) ... UA75(RA)LD751SBN073508R100010.115LD751SBC580742F0301Technical dataTy pesLD75Rated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VMain terminalsScrew terminals with single connector 10x11 mmConnection capacity (min. ... max.)RigidSolid (≤ 4 mm²)1 x 6...50 mm²Stranded (≥ 6 mm²)2 x 6...25 mm²Flexible with ferrule1 x 6...35 mm²2 x 6...16 mm²Bars10 mmTightening torque4 NmDegree of protectionIP10acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Screw terminalsDelivered in closed positionM6Screwdriver typepozidriv 2Note: The utilization of LD additional terminal blocks leaves the possibility to connect the following cables directly into the contactor main terminals.LD75Possible cross section of rigid cable in the contactor terminals50 mm²Terminal enlargementsEnlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger connections to be mounted.Sets containing 3 tin plated copper bars fixed by an isolating spacer.For contactors DimensionsTy pe Order codePkg qtyWeight(1 pce)hole Ø mmbar mmkgUA95, UA1106.515 x 3LW1101SFN074307R100010.100LW1SFT98000-011C3 3/292ABB MOTOR PROTECTION AND CONTROL1SBC101534S0201 - Rev. B03
—Terminals for control lead connectionsTerminals designed to connect the control conductors to the main poles of the UA and GA contactors and derivative versions.Accessories clipped into the slots placed above each power terminal connector. The LK75 are fitted with a pin designed to hold them in place until the connector has been fully clamped with its power cable.• Degree of protection IP20• Connecting terminal delivered in open position: cable clamp and M3.5 (+,-) pozidriv 2 screw.• Cable cross-sectional area: - 1 or 2 rigid conductors ...........................................1...4 mm² - 1 or 2 flexible conductors with cable end .........0.75...2.5 mm²• Tightening torque for the LK screw: - recommended .........................................................1.00 Nm - maxi. ..........................................................................1.20 NmFor contactorsTy pe Order codePkg qtyWeight(1 pce)kgRight and left on:UA50(RA) ... UA75(RA)GA75, GAE75LK75-L1SBN073552R100320.006Opposite on:UA50(RA) ... UA75(RA)GA75, GAE75LK75-F1SBN073552R100220.006Note: The LK terminals provided for the UA contactors can be used with the AM types.LK75-LLK75-F13 0.51"13 0.51"19 0.75"13 0.51"11 0.43"19 0.75"LK75-LLK75-F1SBC575763F03011SBC575773F0301LK positioningMain dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 3/2931SBC101535S0201 - Rev. B03
1SFC101185C0201 - Rev. A3/294ABB MOTOR PROTECTION AND CONTROLFor contactorsTy peOrder codePkg qtyWeight(1 pce)kgConnection bar for contactorGAF185LP1851SFN074712R100020.300GAF300LP3001SFN075112R100020.400GAF460LP4601SFN075712R100040.550GAF750LP7501SFN076112R100040.950GAF1250LP12501SFN076412R100041.900GAF1650, GAF2050LP20501SFN076512R100042.900Maximum continuous current with two parrallel connection strips per poleConnexion kit (includes 4 pcs of connection strips)Ie max2 x LP185220 A2 x LP300370 A1 x LP460600 A1 x LP750800 A1 x LP1250900 A1 x LP20501650 A—Connection bar for contactorLP1851SFC101114F0001LP20501SFC101117F000103
—Contactor coils and main contact setsContactor coilsFor contactorsRated control circuitTy peOrder codePkgqtyWeightvoltageUc(1 pce)V 50 HzV 60 HzkgUA16,2424ZA161SBN151410R810610.093110110...120ZA161SBN151410R840610.093220...230230...240ZA161SBN151410R800610.093230...240240...260ZA161SBN151410R880610.093380...400400...415ZA161SBN151410R850610.093400...415415...440ZA161SBN151410R860610.093UA26, UA30,2424ZA401SBN152410R810610.148110110...120ZA401SBN152410R840610.148220...230230...240ZA401SBN152410R800610.148230...240240...260ZA401SBN152410R880610.148380...400400...415ZA401SBN152410R850610.148400...415415...440ZA401SBN152410R860610.148UA50 ... UA752424ZA751SBN153510R810610.166GA75110110...120ZA751SBN153510R840610.166220...230230...240ZA751SBN153510R800610.166230...240240...260ZA751SBN153510R880610.166380...400400...415ZA751SBN153510R850610.166400...415415...440ZA751SBN153510R860610.166UA95, UA1102424ZA1101SFN154310R810610.170110110...120ZA1101SFN154310R840610.170220...230230...240ZA1101SFN154310R800610.170230...240240...260ZA1101SFN154310R880610.170380...400400...415ZA1101SFN154310R850610.170400...415415...440ZA1101SFN154310R860610.170GAF460-24...60ZAF4601SFN155770R680610.52548...13048...130ZAF4601SFN155770R690610.525100...250100...250ZAF4601SFN155770R700610.525250...500250...500ZAF4601SFN155770R710610.525GAF750 ... AF1250-24...60ZAF7501SFN156170R680611.33548...13048...130ZAF7501SFN156170R690611.335100...250100...250ZAF7501SFN156170R700611.335250...500250...500ZAF7501SFN156170R710611.335GAF1650 ... GAF2050100...250100...250ZAF1650 (1)1SFN156570R70261 set0.900ZP1650 (2)1SFN166521R107010.300ZAF460, ZAF750 : printed circuit board included.(1) One set of two coil.(2) Printed circuit board.Main contact setsThe contact sets for 3-pole contactors consists of six fixed contacts, three moving contacts, springs and the required screws.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgUA50ZLU501SBN163502R100010.115UA63ZLU631SBN163702R100010.145UA75ZLU751SBN164102R100010.145UA95ZLU951SFN164302R100010.190UA110ZLU1101SFN164502R100010.1901SBC573802F0302ZA161SFC101007F0201ZAF1650 ABB MOTOR PROTECTION AND CONTROL 3/2951SFC101143C0201 - Rev B03
—Accessories for EK550, EK1000 4-pole contactors3/298 Auxiliary contact blocks3/302 Mechanical interlock units, terminal shrouds and connection sets3/303 Surge suppressors for contactor coils3/305 Main contact sets - Arc chutes3/306 Contactor coils3/404 Voltage code table— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R1310 ABB MOTOR PROTECTION AND CONTROL 3/29703
1SFC101221C02013/298ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocksThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.Types of auxiliary contact blocks for standard industrial environments:•CAL instantaneous with N.O. + N.C. contacts•CCL N.O. leading contact + N.C. lagging contact.The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact, and bear the corresponding function marking. Mounting: Screwed onto the right and / or lefthand side of the EK550, EK1000 contactors.For contactorsNumber of blocks Auxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kg2-pole auxiliary contacts N.O. + N.C.EK11 1– –CAL16-11ASK829002-A10.05011 1– –CAL16-11BSK829002-B10.05011 1– –CAL16-11CSK829002-C10.05011 1– –CAL16-11DSK829002-D10.05011––1 CCL16-11E (1)SK829002-E10.050(1) Mounting of CCL16-11E blocks does not allow an additional second block to be added on top of it.All DC operated EK contactors are equipped with one CCL16-11E on the right side.E2074DMounting positions of the CAL16-1103
1SBC101656S0201ABB MOTOR PROTECTION AND CONTROL 3/299—Auxiliary contact blocks Technical dataTy pes2-pole CAL 16-11, 2-pole CCL 16-11Contact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated operational voltage Ue max.24...690 VConventional thermal current Ith - θ ≤ 40 °C10 ARated frequency (without derating)50/60 HzIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V6 A220-240 V6 A380-440 V4 A500-690 V1 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC6 A48 V DC6 A72 V DC4 A125 V DC 1.8 A250 V DC 0.6 AShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s50 Aθ = 40 °Cfor 0.1 s100 AMinimum switching capacitywith failure rate acc. to IEC 60947-5-40.25 VA / 12 V or 0.25 VA / 5 mAPower dissipation per pole at 6 A0.2 WMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hElectrical durabilityNumber of operating cyclessee "Electrical durability" curvesMax. switching frequency1200 cycles/hContact utilization characteristics according to UL / CSAMax. operational voltage600 VPilot dutyA600Connecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 0.5...2.5 mm²2 x 0.5...2.5 mm²Flexible with ferrule1 x 0.5...2.5 mm²2 x 0.5...2.5 mm²Flexible with insulated ferrule1 x 0.5...1.5 mm²2 x 0.5...1.5 mm²L6LugsL ≤ 8 mml >3.7 mmTightening torqueRecommended1.00 NmMax.1.20 NmDegree of protection IP20acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3.5Screwdriver typePozidriv 203
1SBC101657S02013/300 ABB MOTOR PROTECTION AND CONTROL—Auxiliary contactsElectrical durabilityElectrical Durability for AC-15 Utilization CategoryAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:• making current: 10 x Ie with cos φ = 0.7 and Ue• breaking current: Ie with cos φ = 0.4 and Ue.This curve represents the electrical durability of the auxiliary contacts in relation to the breaking current.The curve has been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.Breaking current (A)0.020.050.10.30.51245100.10.20.30.51235102030Million operating cycles360.22-pole CAL16... and CCL16... auxiliary contact blocksElectrical Durability for DC-13 Utilization CategoryDC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1:• making and breaking current = Ie with Ue value.Example:Control of d.c. electro-magnet: Ue voltage = 72 V d.c. and breaking power = 70 W.On the opposite curve at intersection "O" 72 V / 70 W the correspon-ding value for the electrical durability is approx-imately 2.106 cycles.2-pole CAL16... and CCL16... auxiliary contact blocksVoltage (V)Breaking power (W)101105205021007020 2425010020050050721.10 cycles63.10 cycles610.10 cycles603
1SBC101687S0201 ABB MOTOR PROTECTION AND CONTROL 3/301CAL16-11ACAL16-11B2-pole auxiliary contacts—Add-on auxiliary contactsTerminal marking and positioning43443132NONC21221314NONC61625354NONC83847172NONC47483536NONCCAL16-11CCAL16-11 DCAL16-11E03
1SFC101222C02013/302ABB MOTOR PROTECTION AND CONTROL—Mechanical interlock units, terminal shrouds and connection setsMechanical interlock unitsThe mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed.VH800 interlock unit is used for the mechanical interlocking of two horizontal mounted EK550, EK1000 contactors. Mounting plate is included.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgMechanical interlock unit for two horizontal mounted contactorsEK550, EK1000VH800SK829070-F16.000A090C4Terminal shroudsThe use of terminal shrouds on the main terminals of EK contactors is required in electrical panels or cubicles to be built in compliance with the rules for protection against direct contact with live parts in acc. with EN 50274. On EK550, EK1000 contactors:•The auxiliary contact blocks and coils are designed to provide an IP20 degree of protection•The main terminals, equipped with lugs or connectors, can be protected against accidental di-rect contact after wiring (EN 50274) by the addition of terminal shrouds (see table below).Each terminal shroud protects all the terminals on one side of the contactor. Two terminal shrouds should be provided for each separate contactor.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgEK550LT550-EKSK178001-LB10.190EK1000LT1000-EKSK178001-MB10.200Connection setsConnection between the main poles of two 4-pole contactors mounted side by side so that they operate as source reversing contactors.These sets are made up of four downstream connections. BSS550, BSS1000 – Bare, solid copper bars.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgMechanical and electrical interlock units for two horizontal mounted contactorsEK550BSS550SK829090-E13.300EK1000BSS1000SK829090-H15.500A1A2A1A23153514264627788E0747DBSS550, BSS100003
1SFC101223C0201 ABB MOTOR PROTECTION AND CONTROL 3/303—Surge suppressors for contactor coils01000100(V)T (s)01000100A 884DThe operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to breakdown of in-sulators and even destruction of certain sensitive components. The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of 3500 V.Overvoltage Factor The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil rated control voltage Uc: Ûs max. Ûs max. Ûs max.k = in DC: k = or in AC: k = Ûc Uc Uc√2 3500 For example the following is obtained for the above graph: k = ≈ 60 42 √2To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppres-sors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies.Each case is different, but the technical data tolerances and the generous sizing of parts have en-abled us to reduce the number of variants.We have chosen the following solutions: transil diodes, varistors and RC blocks. Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.For contactors Rated control circuit voltage UcType Order codePkg qtyWeight(1 pce)VACDCkgEK550, EK100048...110●–RC-EH800/110SK829007-C10.015EK550, EK100024...125–●RC-EH800/110SK829007-C10.015EK550, EK1000220...600●–RC-EH800/600SK829007-D10.015A078RC-EH03
1SFC101224C02013/304ABB MOTOR PROTECTION AND CONTROL—Surge suppressors for contactor coilsTechnical dataVaristor + RCRC- E H800/110RC-EH800/600Rated control circuit voltage Uc48...110 V AC220...600 V AC24...125 V DC–Residual overvoltage (clipping voltage)205 V AC1100 V AC205 V DC–Opening time growth factor1.1 ... 1.15Operating temperature-20 ... +70 °CConnection to the coil terminals (parallel mounting)Flexible, accessible leads, equipped with forked lugsFixingGlued to the top part of the contactor baseAdvantages- High energy absorption: good damping - Unpolarized system - The RC system damps the voltage front under the Uvdr (1) threshold.(1) Uvdr = Varistor operating (voltage dependant resistor), tolerance ±10 %.Wiring diagramsA1A2E0736DUVaristor + RCMain dimensions mm1557.517530E0845DRC-EH03
1SFC101226C0201ABB MOTOR PROTECTION AND CONTROL 3/305—Main contact setsArc chutesMain contact setsThe contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs and the necessary screws. In addition, the sets include four moving arcing contacts for EK550, EK1000 contactors.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgEK550KZK550SK827204-B12.400EK1000KZK1000SK827204-F13.000Arc chutesThe arc chutes sets for EK 4-pole contactors contain 8 pieces.For contactorsTy pe Order codePkg qtyWeight(1 pce)kgEK550KWK5505223351-Z13.170EK1000KWK10005223351-AN13.1701SBC586473F0304KZK03
1SFC101227C02013/306ABB MOTOR PROTECTION AND CONTROL—Contactor coilsFor AC operated coilCoils for EK550, EK1000 - AC operated.For contactors Rated control circuit voltageUc(1)Type Order codePkgqtyWeight(1 pce)V 50 HzV 60 HzkgEK550, EK100048-KH800SK828100-AD10.950110110...120KH800SK828100-EF10.950110...115115...127KH800SK828100-EG10.950220220...240KH800SK828100-EL10.950220...230230...255KH800SK828100-EM10.950380...400400...440KH800SK828100-ER10.950400...415-KH800SK828100-AR10.950(1) Other control voltages, see voltage code table.1SBC273813F0302KH800For DC operated coil Coils for EK550, EK1000 - DC operated with sets including a DC coil, an economy resistor and a insertion contact.For contactors Rated control circuit voltageUc (1)Ty pe Order codePkgqtyWeight(1 pce)V DCkgEK550, EK100024KP800SK828150-DB1 set1.060110KP800SK828150-DE1 set1.060125KP800SK828150-DU1 set1.060220KP800SK828150-DF1 set1.060(1) Other control voltages, see voltage code table.03
ABB MOTOR PROTECTION AND CONTROL 3/30703—Notes
3/308ABB MOTOR PROTECTION AND CONTROL
—Contactors and contactor relays Terminal marking and positioning, Dimensions — For direct product details information, use product type or order code, ex:•www.abb.com/productdetails/AF09-30-10-13•or www.abb.com/productdetails/1SBL137001R1310Terminal marking and positioning3/310 AF, AF..K, AFS 3-pole contactors3/314 AF, EK 4-pole contactors3/317 UA, UA ... RA contactors3/319 NF contactor relays Dimensions3/321 AF, AFS, AF ... K 3-pole contactors3/357 AF, EK 4-pole contactors3/372 GA, GAF contactors3/379 UA, UA ... RA contactors3/382 NF contactor relays3/404 Voltage code tableABB MOTOR PROTECTION AND CONTROL 3/309
1SBC101463S0201 - Rev. B3/310ABB MOTOR PROTECTION AND CONTROLAF09 ... AF16..-30-10 (1)AF09 ... AF96..-30-22AF40 ... AF96..-30-11AF09 ... AF16..-30-01 (1)AF26 ... AF96..-30-00 (1)AF26 ... AF38..-30-11AF09 ... AF16..-30-01 (1)AF26 ... AF38..-30-11AF26 ... AF96..-30-00 (1)AF40 ... AF96..-30-11AF09 ... AF16..-30-10 (1)AF09 ... AF16..-30-22Combination 11 = AF09 ... AF16..-30-10 + CA4-01 (1)Combination 21 = AF09 ... AF16..-30-10 + CAT4-11MCombination 32 = AF09 ... AF16..-30-10 + CA4-22M (1)Combination 11 = AF26 ... AF96..-30-00 + CA4-10 + CA4-01 (1)Combination 21Combination 32Combination 21Combination 11Combination 21 = CAL4-11 + AF09 ... AF16..-30-10 (1)13NONO145L36T33L24T21L12T1A1 A2A1 A221NCNC225L36T33L24T21L12T1A1 A2A1 A25L36T33L24T21L12T1A1 A2A1 A25L33L2A1A26T34T21L12T113NONO145L33L2A1A26T34T21L12T121NCNC225L33L2A1A26T34T21L12T1=+-1NC-213NO145L36T33L24T21L1NO2T121NC22A1 A2A1 A2A1 A22-2-13NO5L33L21L1146T34T2NO2T1A1 A2=++-3NO-4-1NC-25L36T33L24T21L113NO2T114A1 A221NC22A1 A2A1 A21-1-2-2-5L33L21L16T34T22T1A1 A2 =+A121NC2233NO34A213NO5L33L21L1146T34T2NO2T113NO145L36T33L24T21L1A1NO2T121NC2233NO34A2=+13NO145L36T33L24T21L1NO2T1A1 A231NC3221NC2243NO4453NO542131NCNC32224353NO NO4454A1 A2A1 A213NO5L33L21L1146T34T2NO2T1A1 A2=+13XNO21XNCNO14XNC22X13XNO21XNCNO14XNC22X13NONO145L36T33L24T21L12T1A1 A2A1 A213NONO145L36T33L24T21L12T1A1 A2A1 A221NCNC225L33L2A1A26T34T21L12T113NONO1421NCNC225L33L2A1A26T34T21L12T113NONO1433NONO3421NCNC225L33L2A1A26T34T21L12T113NONO1443NONO4453NONO5431NCNC3213XNONO14X21XNCNC22X5L33L2A1A26T34T21L12T113NONO14Note: only AF..Z contactor with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30) need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.(1) For AF09..K ... AF38..K contactors with Push-in Spring terminals, terminal marking and positioning are the same.5L36T33L24T21L143NO31NC21NC13NO2T144322214A1 A2A1 A25L36T33L24T21L121NC13NO2T12214A1 A2A1 A221NCNC225L33L2A1A26T34T21L12T113NONO1443NONO4431NCNC3221NCNC225L33L2A1A26T34T21L12T113NONO1413XNONO14X21XNCNC22X5L33L2A1A26T34T21L12T113XNO21XNCNO14XNC22X6T33L24T21L12T1A1 A2A1 A25L3AF26 ... AF96..-30-225L36T33L24T21L143NO31NC21NC13NO2T144322214A1 A2A1 A2—AF09 ... AF96 3-pole contactorsTerminal marking and positioningAF09 ... AF96 contactors - AC / DC operatedStandard devices without addition of auxiliary contactsOther possible contact combinations with auxiliary contacts added by the user03
1SFC101130C0201 ABB MOTOR PROTECTION AND CONTROL 3/311AF116 ... AF370-30-00AF116 ... AF370-30-00AF116 ... AF370-30-22AF116 ... AF370-30-11A1A25L36T33L24T21L12T143XNONO44X31XNCNC32X21XNCNC22X13XNONO14XAF116 ... AF370-30-22A1A21L12T13L24T221XNCNC22X5L36T313XNONO14XAF116 ... AF370-30-11A1A21L12T13L24T25L36T3A1A21L13L25L32T14T26T3A1A2NO 13XNC 21XNC 22XNO 14X1L13L25L32T14T26T3A1A2NO 13XNC 21XNC 22XNO 14X43X NO31X NC32X NC44X NO1L13L25L32T14T26T3—AF116 ... AF370 3-pole contactorsTerminal marking and positioningAF116 ... AF370 contactors - AC / DC operatedStandard devices without addition of auxiliary contactsStandard devices with factory mounted auxiliary contacts03
1SFC101131C02013/312ABB MOTOR PROTECTION AND CONTROLNO 13XNC 21XNC 22XNO 14X43X NO31X NC32X NC44X NOA1A21L13L25L32T14T26T3Logicsignal123X5AF400 ... AF1250-30-22NO 13XNC 21XNC 22XNO 14XA1A21L13L25L32T14T26T3Logicsignal123X5AF400 ... AF1250-30-11A1A25L36T33L24T21L12T143XNONO44X31XNCNC32X21XNCNC22X13XNONO14XAF400 ... AF1250-30-22A1A21L12T13L24T221XNCNC22X5L36T313XNONO14XAF400 ... AF1250-30-11ONOFF_NCOMMONONOFF24V+ContactorSupply voltage123X50VA1A2AF400 ... AF1250-30-11, AF400 ... AF1250-30-22Control with logic signalA1A25L36T33L24T21L12T143XNONO44X31XNCNC32X21XNCNC22X13XNONO14XAF1350, AF1650-30-22E2138D3A1A21L12T13L24T221XNCNC22X5L36T313XNONO14XE2139D3AF1350, AF1650-30-111L1A1NO 13XNC 21XNO 22XNO 14XA23L25L32T14T26T3E1689D2GONOFF_NCOMMONONOFF24V+ContactorAF1350, AF1650Supply voltage123X50VA1A2E2693DGONOFF_NCOMMONONOFF24V+ContactorAF1350, AF1650Supply voltage123X50VA1A2AF1350 ... AF2850-30-11AF1350 ... AF2850-30-22Wiring diagramswhen used with transistor output when used with transistor output AF400 ... AF1250 contactors - AC / DC operatedStandard devices with factory mounted auxiliary contacts—AF400 ... AF2850 3-pole contactorsTerminal marking and positioningAF1350 ... AF2850 contactors - AC / DC operatedStandard devices with factory mounted auxiliary contactsAF1350 ... AF2850-30-1103
ABB MOTOR PROTECTION AND CONTROL 3/3131SBC100315S0201 —AFS09 ... AFS750 3-pole contactors for safety applicationsTerminal marking and positioningAFS09 ... AFS96..-30-22AFS09 ... AFS16..-30-225L36T33L24T21L143NO31NC21NC13NO2T144322214A1 A2A1 A221NCNC225L33L2A1A26T34T21L12T113NONO1443NONO4431NCNC32AFS26 ... AFS96..-30-225L36T33L24T21L143NO31NC21NC13NO2T144322214A1 A2A1 A2AFS09 ... AFS96 contactors - AC / DC operatedStandard devicesAFS116 ... AFS370-30-12A1A25L36T33L24T21L12T131XNCNC32X21XNCNC22X13XNONO14XAFS116 ... AFS370-30-12A1A2NO 13XNC 21XNC 22XNO 14X32X NC1L13L25L32T14T26T331X NCAFS116 ... AFS370 contactors - AC / DC operatedStandard devices with factory mounted auxiliary contactsAFS400 ... AFS750 contactors - AC / DC operatedStandard devices with factory mounted auxiliary contactsNO 13XNC 21XNC 22XNO 14X31X NC32X NCA1A21L13L25L32T14T26T3Logicsignal123X5AFS400 ... AFS750-30-12A1A25L36T33L24T21L12T131XNCNC32X21XNCNC22X13XNONO14XAFS400 ... AFS750-30-12ONOFF_NCOMMONONOFF24V+ContactorSupply voltage123X50VA1A2AFS400 ... AFS750-30-12Control with logic signal03
1SBC101480S0201 - Rev. B3/314ABB MOTOR PROTECTION AND CONTROLCombination 11Combination 22Combination 11Combination 10Combination 11Note: only AF..Z contactor with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30) need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.7L48T45L36T33L24T21L12T1A1 A2A1 A278R5R6R3R412A1 A2A1 A25L33L2A1A26T38T44T21L12T17L4R5R3A1A2R6R41278=+-3NO-47L48T45L36T33L24T21L113NO2T114A1 A2A1 A21-1-7L45L33L21L18T46T34T22T1A1 A2A1 A2=++-3NO-4-1NC-213NO1421NC227L45L33L21L18T46T34T22T1A1 A2A1 A21-1-2-2-7L45L33L21L18T46T34T22T1A1 A2A1 A25L33L2A1A26T34T21L12T113NONO147L48T45L33L2A1A26T34T21L12T113NONO147L48T421NCNC22=+A113NO1421NC22A27L48T45L36T33L24T21L1A12T113NO1421NC22A27L45L33L21L18T46T34T22T1=+1321NCNO22143143NC NO32447L48T45L36T33L24T21L12T121NC2213NO1431NC3243NO44A1 A2A1 A27L45L33L21L18T46T34T22T1A1 A2A1 A25L33L2A1A26T34T21L12T113NONO147L48T421NCNC2221NCNC225L33L2A1A26T34T21L12T17L48T413NONO1443NONO4431NCNC32=+13XNO21XNCNO14XNC22X13XNO21XNCNO14XNC22X7L48T45L36T33L24T21L12T1A1 A2A1 A27L48T45L36T33L24T21L12T1A1 A2A1 A221XNCNC22X5L33L2A1A26T34T21L12T17L48T413XNONO14X—AF09 ... AF80 4-pole contactorsTerminal marking and positioningAF09 ... AF38 contactors - AC / DC operatedStandard devices without addition of auxiliary contactsOther possible contact combinations with auxiliary contacts added by the userAF09 ... AF80..-40-00AF09 ... AF40..-22-00AF80-22-00AF09 ... AF80..-40-00Combination 10 = AF09 ... AF80..-40-00 + CA4-10Combination 11 = AF09 ... AF80..-40-00 + CAT4-11ECombination 22 = AF09 ... AF80..-40-00 + CA4-22ECombination 11 = AF09 ... AF80..-40-00 + CA4-10 + CA4-01Combination 11 = CAL4-11 + AF09 ... AF80..-40-00AF09 ... AF40..-22-00AF80-22-0003
AF116 ... AF370-40-00AF116 ... AF370-40-00AF116 ... AF370-40-22AF116 ... AF370-40-11A1A27L48T45L36T31L12T143XNONO44X31XNCNC32X21XNCNC22X13XNONO14X3L24T2AF116 ... AF370-40-22A1A21L12T15L36T321XNCNC22X7L48T413XNONO14X3L24T2AF116 ... AF370-40-11A1A21L12T13L24T25L36T37L48T4A1A21L13L25L37L42T14T26T38T4NO 13XNC 21XNC 22XNO 14XA1A21L13L25L37L42T14T26T38T4NO 13XNC 21XNC 22XNO 14X43X NO31X NC32X NC44X NO—AF116 ... AF370 4-pole contactorsTerminal marking and positioningAF116 ... AF370 contactors - AC / DC operatedStandard devices without addition of auxiliary contactsStandard devices with factory mounted auxiliary contactsA1A21L13L25L37L42T14T26T38T41SFC101215C0201 ABB MOTOR PROTECTION AND CONTROL 3/31503
1SFC101216C02013/316ABB MOTOR PROTECTION AND CONTROL221413211L13L25L37L42T14T26T38T4EK550, EK1000-40-11A1A21234212256131478EK550, EK1000-40-11221413211L13L25L37L42T14T26T38T432444331EK550, EK1000-40-22A1A2123456782122131431324344EK550, EK1000-40-22221413211L13L25L37L42T14T26T38T432444331221413211L13L25L37L42T14T26T38T43244433162545361625453617284837172848371Combination 44 =EK550, EK1000-40-22 +CAL16-11C +CAL16-11DA1A21256783421221314313243445354616283847172345612A1A25354616221221314313243447883847172Combination 44 =EK550, EK1000-40-22 +CAL16-11C +CAL16-11D221413211L13L25L37L42T14T26T38T436484735EK550, EK1000-40-21A1A212345678212213144748EK550, EK1000-40-216254536162545361221413211L13L25L37L42T14T26T38T436484735221413211L13L25L37L42T14T26T38T436484735Combination 32 = EK550, EK1000-40-21 + CAL16-11C345612A1A278A1A2125678342122131461625354616247485354474821221314Combination 32 = EK550, EK1000-40-21 + CAL16-11CR1A2A11314212247483 L21 L14 T22 T15 L36 T33536{V DC7 L48 T4EK550, EK1000 DC operated—EK 4-pole contactorsTerminal marking and positioningEK550, EK1000 contactors - AC operatedStandard devicesOther possible contact combinations with auxiliary contacts added by the userOther possible contact combinations with auxiliary contacts added by the userEK550, EK1000 contactors - with multifrequency coil or DC operatedStandard devicesResistor only forEK550, EK1000Resistor only forEK550, EK1000Resistor only forEK550, EK100003
1SBC101574S0201 ABB MOTOR PROTECTION AND CONTROL 3/317—UA..RA contactorsTerminal marking and positioningUA..RA contactors - AC operatedStandard devices without addition of auxiliary contacts1L13L25L32T14T26T3A1A2A2 13NONO14NONONO273747283848UA16-30-10 R A UA26-30-10 R A1L13L25L32T14T26T3A1A2A2 13NONO14NONONO2737472838485-5-UA30-30-10 RA2737 471L13L25L32T14T26T32838 481-1-5-5-A1A2A2NONONOUA50 ... 110-30-00 R AA1A25L3NONONONO3L21L16T34T22T11314272837384748UA16 ... 30-30-10 R AA1A25L3NONONO3L21L16T34T22T1272837384748UA50 ... 110-30-00 R A03
1SBC101571S02013/318ABB MOTOR PROTECTION AND CONTROL—UA... contactorsTerminal marking and positioningUA... contactors - AC operatedStandard devices without addition of auxiliary contactsStandard devices with factory mounted auxiliary contacts1L13L25L32T14T26T3A1A2A213NONO14UA16 ... UA30-30-10A1A21L12T13L24T25L36T313NONO14UA16 ... UA30-30-10A11L13L25L32T14T26T3A2A2UA50 ... UA110-30-00A1A21L12T15L36T33L24T2UA50 ... UA110-30-00A11L12T1A213X21X14X22XA23L25L34T26T3NCNONONCUA50 ... UA110-30-11A1A21L12T13L24T221XNCNC22X5L36T313XNONO14XUA50 ... UA110-30-1103
1SBC101582S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/319Combination 41 = NF..31E + CA4-10Combination 51 = CAL4-11 + NF..40ECombination 42 = NF..40E + CA4-01+CA4-01 Combination 62 = NF..40E + CA4-22NNote: only NFZ contactor relays with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30) need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.(1) Not available with Contactor relays with Push-in Spring terminals.—NF contactor relaysTerminal marking and positioningStandard devices without addition of auxiliary contactsOther possible contact combinations with auxiliary contacts added by the userN F. . 2 2 E43NO31NC21NC13NOA1 A2A1 A2443222NONCNCNO14N F. . 3 1E43NO4433NO3421NC2213NONONONCNO14A1 A2A1 A2N F. . 4 0 E43NO4433NO3423NO2413NONONONONO14A1 A2A1 A2N F. . 4 4 E43NO4433NO3423NO2413NO81NC71NC61NC51NCNONONONO1482726252A1 A2A1 A2N F. . 2 2 E43NONO4431NCNC3221NCNC2213NONO14A1A2N F. . 4 0 E43NONO4433NONO3423NONO2413NONO14A1A2N F. . 3 1E33NONO3421NCNC2213NONO1443NONO44A1A2N F. . 4 4 E43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A2N F. . 53 E43NO4433NO3423NO2413NO81NC71NC61NC53NONONONONO1482726254A1 A2A1 A2N F. . 3 3/1 1 (1)41NC4233NO3423NO2413NO87NO75NC61NC51NCNCNONONO1488766252A1 A2A1 A2N F. .6 2 E43NO4433NO3423NO2413NO83NO71NC61NC53NONONONONO1484726254A1 A2A1 A2NF..51/11 (1)43NO4433NO3423NO2413NO87NO75NC61NC53NONONONONO1488766254A1 A2A1 A2N F. .7 1E43NO4433NO3423NO2413NO83NO73NO61NC53NONONONONO1484746254A1 A2A1 A2NF..80E43NO4433NO3423NO2413NO83NO73NO63NO53NONONONONO1484746454A1 A2A1 A2N F. . 53 E43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A2N F. .7 1E43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A2N F. .6 2 E43NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A2NF..80E43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A2=+-3NO-443NONONCNO44333421221353NONONONCNO1454A1 A2A1 A2A1 A25-5-43NONONCNO332113443422NONONCNO14A1 A2+-1NC-2=+-1NC-243NONONONO44333423241351NCNONONONO1452A1 A261NC62A1 A2A1 A25-5-6-6-43NONONONO332313443424NONONONO14A1 A2=+21XNCNC22X13XNONO14X13XNO21XNCNO14XNC22X43NO4433NO3423NO2413NONONONONO14A1 A2A1 A243NO4433NO3423NO2413NONONONONO14A1 A2A1 A2=+83NO71NC61NC53NO8472625443NO4433NO3423NO2413NO83NO71NC61NC53NONONONONO1484726254A1 A2A1 A243NO4433NO3423NO2413NONONONONO14A1 A2A1 A233NONO3421NCNC2213NONO1443NONO4453NONO54A1 A2 Combination 41 E43NONO4433NONO3423NONO2413NONO14A1 A2 21XNCNC22X13XNONO14XCombination 51 E43NONO4433NONO3423NONO2413NONO1453NONO5471NCNC7283NONO8461NCNC62A1 A2 Combination 62 E43NONO4433NONO3423NONO2413NONO14A1 A2 61NCNC6251NCNC52Combination 42 EA1A241NCNC4233NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6251NCNC52NF..33/11 (1) A1A243NONO4433NONO3423NONO2413NONO1487NONO8875NCNC7661NCNC6253NONO54NF..51/11 (1)03
1SBC101582S0201 - Rev. B3/320ABB MOTOR PROTECTION AND CONTROL—NF add-on auxiliary contactsTerminal marking and positioning1-pole auxiliary contacts2-pole auxiliary contacts4-pole auxiliary contacts-1NC-2CA4-016162535481827172NONCNCNCCA4-13N5354636473748384NONONONOCA4-40N5354616273748384NONONONCCA4-31N6162535483847172NONCNCNOCA4-22N6162515281827172NCNCNCNCCA4-04N13X / NO14X / 21X / NC22X / 44X43X31X32XCAL4-11(Left side-mounted)NCNO31X / 22X32X / 21X43X / 14X44X / 13XCAL4-11(Right side-mounted)-5NC-6CC4-01-3NO-4CA4-10-7NO-8CC4-1003
1SBC101682S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/32145 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"43 1.69"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 607155.5 0.22"10 0.39"45 1.77"12 0.47"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"—AF09, AF12, AF16 3-pole contactorsDimensionsMain dimensions mm, inches (1)AF09, AF12, AF16AF09, AF12, AF16+ CA4, CC4 1-pole auxiliary contact blockAF09, AF12, AF16..-30-22AF09, AF12, AF16+ TEF4 electronic timer AF09, AF12, AF16AF09, AF12, AF16+ CAL4-11 2-pole auxiliary contact blockAF09, AF12, AF16+ CAT4 2-pole auxiliary contact and coil terminal blockAF09, AF12, AF16+ CA4 4-pole auxiliary contact block45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"45 1.77"80 3.15"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"(1) Note: For AF09 ... AF16 contactors, lateral distance to grounded component 2 mm 0.08" min.24 V DC operated contactor (coil 30) depth + 20 mm + 0.79".35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"45 1.77"80 3.15"6 0.24"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"1.1 0.04"5.5 0.22"133.5 5.26"40.5 1.59"03
1SBC101682S0201 - Rev. B3/322ABB MOTOR PROTECTION AND CONTROLAF09, AF12, AF16+ VEM4 mechanical and electrical interlock setAF09, AF12, AF16+ VEM4 mechanical and electrical interlock set90 3.54"91.5 3.60"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"91.5 3.60"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC45 1.77"156.1 6.15"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 60715100.39"5.5 0.22"6.20.24"72.7 2.86"76.8 3.02"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF09, AF12, AF16+ TF42, EF19AF09, AF12, AF16+ TF42 thermal overloard relayAF09, AF12, AF16 3-pole contactors+ EF19 electronic overload relay—AF09, AF12, AF16 3-pole contactorsDimensionsMain dimensions mm, inches (1)45 1.77"152.4 6.00"77 3.03"76.8 3.02"73.3 2.89"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"17.4 0.69"5.5 0.22"(1) Note: For AF09 ... AF16 contactors, lateral distance to grounded component 2 mm 0.08" min.24 V DC operated contactor (coil 30) depth + 20 mm + 0.79".03
1SBC101683S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/323—AF26, AF30, AF38 3-pole contactorsDimensionsMain dimensions mm, inches (1)45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26, AF30, AF38AF26, AF30, AF3845 1.77"80 3.15"6 0.24"119.5 4.70"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"80 3.15"6 0.24"12 0.47"45 1.77"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26, AF30, AF38+ CA4, CC4 1-pole auxiliary contact blockAF26, AF30, AF38+ CAL4-11 2-pole auxiliary contact block45 1.77"80 3.15"6 0.24"119.5 4.70"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"111.5 4.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"45 1.77"80 3.15"AF26, AF30, AF38+ CAT4 2-pole auxiliary contact and coil terminal blockAF26, AF30, AF38+ CA4 4-pole auxiliary contact block(1) Note: For AF26 ... AF38 contactors, lateral distance to grounded component 2 mm (0.08") min.24 V DC operated contactor (coil 30) depth + 20 mm (+ 0.79").45 1.77"80 3.15"40.5 1.59"6 0.24"1.1 0.04"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"142.5 5.61"AF26, AF30, AF38+ TEF4 electronic timer45 1.77"80 3.15"6 0.24"111.5 4.30"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AF26, AF30, AF38..-30-11AF26, AF30, AF38..-30-2203
1SBC101683S0201 - Rev. B3/324ABB MOTOR PROTECTION AND CONTROL60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"91.5 3.60"111.5 4.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"91.5 3.60"111.5 4.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"43 1.69"AF26, AF30, AF38+ VEM4 mechanical and electrical interlock setAF26, AF30, AF38+ VEM4 mechanical and electrical interlock setAF26, AF30, AF38+ TF42, EF19, EF45—AF26, AF30, AF38 3-pole contactorsDimensionsMain dimensions mm, inches (1)(1) Note: For AF26 ... AF38 contactors, lateral distance to grounded component 2 mm (0.08") min.24 V DC operated contactor (coil 30) depth + 20 mm (+ 0.79").45 1.77"158.9 6.26"86 3.39"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF26, AF30, AF38 + TF42 thermal overload relay45 1.77"158.9 6.26"86 3.39"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"155.2 6.11"86 3.39"76.3 3.00"79.8 3.14"80 3.15"10 0.39"20.4 0.80"35 mm EN/IEC 607155.5 0.22"5.5 0.22"45 1.77"172.3 6.78"86 3.39"82.5 3.25"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26 3-pole contactors+ EF19 electronic overload relayAF26, AF30, AF38 3-pole contactors+ EF45 electronic overload relay03
1SBC101731S02011SBC101731S0201 ABB MOTOR PROTECTION AND CONTROL 3/325—AF40 ... AF65 3-pole contactorsDimensionsMain dimensions mm, inchesAF40, AF52, AF65AF40, AF52, AF65111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"5.50.22"45 1.77"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC2 x2 xAF40, AF52, AF65+ CA4, CC4 1-pole auxiliary contact blockAF40, AF52, AF65-30-00 + CAL4-11 2-pole auxiliary contact blockAF40, AF52, AF65-30-11111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69"5.50.22"111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"12 0.47"10 0.39"35 mm EN/IEC 607155.5 0.22"AF40, AF52, AF65+ CA4 4-pole auxiliary contact blockAF40, AF52, AF65+ CAT4 2-pole auxiliary contact and coil terminal block111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69"111 4.37"7 0.28"55 2.17"119.5 4.70"100.39"35 mm EN/IEC 607155.5 0.22"136 5.35"43 1.69"AF40, AF52, AF65..-30-22AF40, AF52, AF65+ TEF4 electronic timer111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"10 0.39"35 mm EN/IEC 607155.5 0.22"144 5.67"43 1.69"111 4.37"7 0.28"6 0.24"55 2.17"119.5 4.70"35 mm EN/IEC 607155.5 0.22"10 0.39"1.1 0.04"40.5 1.59"167 6.57"5.50.22"03
1SBC101731S02013/326ABB MOTOR PROTECTION AND CONTROL—AF40 ... AF65 3-pole contactorsDimensionsMain dimensions mm, inches110 4.33"6 0.24"119.5 4.70"111 4.37"7 0.28"5.5 0.22"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715100 3.94"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNCAF40, AF52, AF65+ VM96-4 mechanical interlock unitAF40, AF52, AF65+ TF65 thermal overload relayAF40, AF52, AF65+ EF65 electronic overload relayAF40, AF52, AF65+ VM96-4 mechanical interlock setAF40, AF52, AF65+ TF65, EF6545 1.77"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC2 x2 x111 4.37"7 0.28"55 2.17"10 0.39"35 mm EN/IEC 607155.5 0.22"106.8 4.20"110.6 4.35"4 0.16"208.5 8.21"111 4.37"7 0.28"55 2.17"10 0.39"35 mm EN/IEC 607155.5 0.22"237 9.33"70 2.76"106.8 4.20"110.6 4.35"5.4 0.21"03
1SBC101732S0201 ABB MOTOR PROTECTION AND CONTROL 3/3271SBC101732S0201—AF80 ... AF96 3-pole contactorsDimensionsMain dimensions mm, inchesAF80, AF96AF80, AF966 0.24"119.5 4.70"70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 607155.5 0.22"ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"AF80, AF96+ CA4, CC4 1-pole auxiliary contact blockAF80, AF96-30-00 + CAL4-11 2-pole auxiliary contact blockAF80, AF96-30-116 0.24"119.5 4.70"70 2.76"116 4.57"7 0.28"100.39"5.5 0.22"149 5.87"43 1.69"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"5.5 0.22"70 2.76"116 4.57"10 0.39"12 0.47"7 0.28"35 x 15 mm EN/IEC 60715AF80, AF96+ CA4 4-pole auxiliary contact block43 1.69"6 0.24"119.5 4.70"70 2.76"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607155.5 0.22"AF80, AF96..-30-2243 1.69"6 0.24"119.5 4.70"70 2.76"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607155.5 0.22"AF80, AF96+ TEF4 electronic timer6 0.24"119.5 4.70"70 2.76"116 4.57"7 0.28"10 0.39"1.1 0.04"5.5 0.22"35 x 15 mm EN/IEC 6071540.5 1.59"172 6.77"5.5 0.22"03
1SBC101732S02013/328ABB MOTOR PROTECTION AND CONTROL—AF80 ... AF96 3-pole contactorsDimensionsMain dimensions mm, inches140 5.51"6 0.24"119.5 4.70"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715130 5.12"ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCAF80, AF96+ VM96-4 mechanical interlock unitAF80, AF96+ TF96 thermal overload relayAF80, AF96+ EF96 electronic overload relayAF80, AF96+ VM96-4 mechanical interlock setAF80, AF96+ TF96, EF96ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"237 9.33"106.8 4.20"110.6 4.35"5.4 0.21"35 x 15 mm EN/IEC 6071570 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"106.8 4.20"211 8.31"110.9 4.37"4 0.16"35 x 15 mm EN/IEC 6071503
1SFC101118C0201 ABB MOTOR PROTECTION AND CONTROL 3/329—AF116, AF140, AF146 3-pole contactorsDimensionsMain dimensions mm, inchesAF116, AF140, AF146-30-00 + CAL19 2-pole auxiliary contact block AF116, AF140, AF146-30-11AF116, AF140, AF146-30-..(B)AF116, AF140, AF146-30-00B + CAL19 2-pole auxiliary contact block AF116, AF140, AF146-30-11B100 3.94"30 1.18"M4 8-32 UNCSECTION D-D SECTION E-E 55.5 0.22"90 3.54"19.5 4.96"126 4.96"30 1.18"3 0.12"14.2 0.56"14.2 0.56"14.2 0.56"20 0.79"DDE150 5.91"10 0.39"SECTION D-D ESECTION E-E 3 0.12"ø 6.5 0.26"23.8 0.94"22.8 0.90"5.5 0.22"20 0.79"55.5 2.18"19.5 0.77"126 4.96"90 3.54"150 5.91"30 1.18"23.8 0.94"DD10 0.39"03
1SFC101118C02013/330ABB MOTOR PROTECTION AND CONTROL—AF116, AF140, AF146 3-pole contactors With built-in PLC interface (coil code 33, 34)DimensionsMain dimensions mm, inchesAF116, AF140, AF146-30-00 + CAL19 2-pole auxiliary contact block AF116, AF140, AF146-30-11AF116, AF140, AF146-30-..(B)AF116, AF140, AF146-30-00B + CAL19 2-pole auxiliary contact block AF116, AF140, AF146-30-11B100 3.94"30 1.18"M4 8-32 UNCSECTION D-D SECTION E-E 55.5 0.22"90 3.54"19.5 4.96"30 1.18"3 0.12"14.2 0.56"14.2 0.56"14.2 0.56"20 0.79"DDE150 5.91"10 0.39"142.5 5.61"SECTION D-D ESECTION E-E 3 0.12"ø 6.5 0.26"23.8 0.94"22.8 0.90"5.5 0.22"20 0.79"55.5 2.18"19.5 0.77"142.5 5.61"90 3.54"150 5.91"30 1.18"23.8 0.94"DD10 0.39"03
1SFC101118C0201 ABB MOTOR PROTECTION AND CONTROL 3/331—AF116, AF140, AF146 3-pole contactorsDimensionsMain dimensions mm, inches24 0.94"226 8.90"30 1.18"90 3.54"ø 6.4 0.25"13 0.51"8 0.31"126 4.96"17 0.67"3 0.12"29.5 1.16"AF..-30-11 233 9.17"41 1.61"108 4.25"126 4.96"ø 6 0.24"15 0.59"7.5 0.3"17 0.67"3 0.12"AF..-30-11B 228 8.98"24 0.94"226 8.90"30 1.18"90 3.54"ø 6.4 0.25"13 0.51"8 0.31"126 4.96"17 0.67"3 0.12"AF116, AF140, AF146-30-11 + LX140 terminal extensionAF116, AF140, AF146-30-11(B) + LW140(B) terminal enlargement150 5.91"180 7.09"126 4.96"AF116, AF140, AF146-30-11(B) + VM19 mechanical interlocking unit60 2.36"8x30 1.18"M4 8-32 UNC100 3.94"30 1.18"AF116, AF140, AF146-30-11(B) + VM19 mechanical interlocking unit150 5.91"180 7.09"126 4.96"03
1SFC101118C02013/332ABB MOTOR PROTECTION AND CONTROL—AF116, AF140, AF146 3-pole contactorsDimensionsMain dimensions mm, inchesAF116, AF140, AF146-30-11(B) + EF146 electronic overload relayAF116, AF140-30-11(B) + TF140 thermal overload relay126 4.96"90 3.54"259 10.20"17 0.67"3 0.12"6 0.24"8 0.31"100 3.94"45 1.77"82.3 3.24"30 1.18"37 1.46"50 1.97"M4 8-32 UNCM5 10-24 UNC4 x4 x126 4.96"105 4.13"90 3.54"270 10.63"17 0.67"3 0.12"100 3.94"46 1.81"94.7 3.73"30 1.18"37 1.46"M4 8-32 UNCM5 10-24 UNC6 x2 x21.50.85"AF116, AF140, AF146-30-11(B) + EF146 electronic overload relayAF116, AF140-30-11(B) + TF140 thermal overload relay03
1SFC101119C0201 ABB MOTOR PROTECTION AND CONTROL 3/333—AF190, AF205 3-pole contactorsDimensionsMain dimensions mm, inchesAF190, AF205-30-00 + CAL19 2-pole auxiliay contact block AF190, AF205-30-11AF190, AF205AF190, AF205-30-11+ LX205 terminal extension B105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"152 5.98"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 125 4.92"20 0.79"27 1.06"10 0.37"ø 10.5 0.41"45 1.77"152 5.98"299 11.77"30.5 1.20"5 0.20"105 4.13"17.5 0.69"ø 8.5 0.33"152 5.98"30.5 1.20"5 0.20"27 1.06"10 0.39"35 1.38"299 11.77"AF190, AF205-30-11+ LW205 terminal enlargement165 6.50"35 1.38"M5 10-24 UNC4 X03
1SFC101119C02013/334ABB MOTOR PROTECTION AND CONTROL—AF190, AF205 3-pole contactors With built-in PLC interface (coil code 33, 34)DimensionsMain dimensions mm, inchesAF190, AF205-30-00 + CAL19 2-pole auxiliay contact block AF190, AF205-30-11AF190, AF205B105 4.13"ø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION B-B 169.5 6.67"165 6.50"35 1.38"M5 10-24 UNC4 X03
1SFC101119C0201 ABB MOTOR PROTECTION AND CONTROL 3/335—AF190, AF205 3-pole contactorsDimensionsMain dimensions mm, inchesAF190, AF205-30-11 + VM19 mechanical interlocking unitAF190, AF205 + VM19 mechanical interlocking unit210 8.27"152 5.98"196 7.727"35 1.38"70 2.76"35 1.38"M5 10-24 UNC6 X165 6.50"03
1SFC101119C02013/336ABB MOTOR PROTECTION AND CONTROL—AF190, AF205 3-pole contactorsDimensionsMain dimensions mm, inchesAF190, AF205-30-11 + TA200DU thermal overload relay105 4.13"312.5 12.3"152 5.98"35.5 1.40"5 0.20"62 2.44"42.5 1.67"20 0.79"ø 11 0.43"126 4.96"4 0.16"11 0.43"21 0.83"82 3.23"25.51.0"35 1.39"37 1.46"50 1.97"M5 10-24 UNC8 x165 6.50"AF190, AF205+ TA200DU thermal overload relay03
1SFC101119C0201 ABB MOTOR PROTECTION AND CONTROL 3/337AF190, AF205-30-11 + EF205 electronic overload relay105 4.13"342 13.46"152 5.98"35.5 1.40"5 0.20"35 1.38"35 1.38"17.5 0.69"8.5 0.33"123 4.84"5 0.20"10 0.39"35 1.38"20.50.81"112 4.42"35 1.39"M5 10-24 UNC8 x165 6.50"—AF190, AF205 3-pole contactorsDimensionsMain dimensions mm, inchesAF190, AF205 + EF205 electronic overload relay03
1SFC101120C0201 - Rev. B3/338ABB MOTOR PROTECTION AND CONTROL—AF265, AF305, AF370 3-pole contactorsDimensionsMain dimensions mm, inchesAF265, AF305, AF370-30-00 + CAL19 2-pole contact block AF265, AF305, AF370-30-11AF265, AF305, AF370140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"187 7.36"43.75 1.72"M5 10-24 UNC4 X03
1SFC101120C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/339—AF265, AF305, AF370 3-pole contactors with built-in PLC interface (coil code 33, 34)DimensionsMain dimensions mm, inchesAF265, AF305, AF370-30-00 + CAL19 2-pole contact block AF265, AF305, AF370-30-11AF265, AF305, AF370140 5.51"19.5 0.77"ø 10.5 0.41"43.75 1.72"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"195.5 7.70"187 7.36"43.75 1.72"M5 10-24 UNC4 X03
1SFC101120C0201 - Rev. B3/340ABB MOTOR PROTECTION AND CONTROL—AF265, AF305, AF370 3-pole contactorsDimensionsMain dimensions mm, inchesAF265, AF305, AF370-30-11+ LX370 terminal extensionAF265, AF305, AF370-30-11+ LW370 terminal enlargement165 6.50"25 0.98"ø 10.5 0.41"62 2.44"180 7.09"354.5 13.96"30.5 1.20"5 0.20"12.5 0.49"31.2 1.23"20 0.79"ø 10.5 0.41"43.75 1.72"180 7.09"354.5 20.02"30.5 1.20"5 0.20"12.5 0.49"32.0 1.28"20 0.79"ø 10.5 0.41"43.75 1.72"180 7.09"354.5 20.02"30.5 1.20"5 0.20"12.5 0.49"32.0 1.28"03
1SFC101120C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/341—AF265, AF305, AF370 3-pole contactorsDimensionsMain dimensions mm, inchesAF265, AF305, AF370-30-11 + VM19 mechanical interlocking unitAF265, AF305, AF370 + VM19 mechanical interlocking unit280 11.02"180 7.09"225 8.86"187 7.36"43.75 1.72"96.25 3.79"43.75 1.72"M5 10-24 UNC8 X03
1SFC101120C0201 - Rev. B3/342ABB MOTOR PROTECTION AND CONTROL—AF265, AF305, AF370 3-pole contactorsDimensionsMain dimensions mm, inchesAF265, AF305, AF370-30-11+ EF370 electronic overload relay385 15.16"140 5.51"180 7.09"123 4.84"44 1.73"43.8 1.72"20 1.79"14 0.55"ø 11 0.43"35.5 1.40"5 0.20"35 1.20"5 0.20"112 4.41"29 1.14"35 1.38"43.75 1.72"M5 10-24 UNC8 x187 7.36"AF265, AF305, AF370+ EF370 electronic overload relay03
1SFC101121C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/34363 2.48"186 7.32"25 0.98"22.5 0.89"11.5 0.45"268 10.55"ø10.5 0.41"ø6.5 0.26"AF400, AF460-30-11216 8.5"48.5 1.91"6 0.24"278 10.94"63 2.48"248 9.76"M5 10-24 UNC63 2.48"186 7.32"25 0.98"11.50.45"472 18.58"ø 10.5 0.41"33 1.3" AF400, AF460-30-11+ LX460 terminal extension181 7.13"25 0.98"120.47"472 18.58"33 1.3"ø10 0.39"78 3.07"AF400, AF460-30-11+ LW460 terminal enlargement216 8.5"44 1.73"5 0.2"139 5.47"AF400, AF460—AF400 and AF460 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101121C0201 - Rev. A3/344ABB MOTOR PROTECTION AND CONTROL63 2.48"402 15.83"268 10.55"301.18"25 0.98"ø10.5 0.41"216 8.5"48.5 1.91"6 0.24"278 10.94"63 2.48"216 8.5"248 9.76"M5 10-24 UNCAF400, AF460 + VM750H mechanical interlock unitAF400, AF460-30-11 + VM750H mechanical interlock unit—AF400 and AF460 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101121C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/34563 2.48"186 7.32"63 2.48"63 2.48"25 0.98"449.5 17.7"63 2.48"192 7.56"25 0.98"11.5 0.45"ø10.50.41"ø10.5 0.41"AF400, AF460-30-11 + EF460 electronic O/L relay216 8.5"48.5 1.91"6 0.24"454.5 17.89"153.5 6.02"46 1.81"5 0.2"63 2.48"6.5 0.26"6.5 0.26"76 2.99"248 9.76"83 3.27"55 2.17"M5 10-24 UNCM5 10-24 UNCAF400, AF460 + EF460 electronic O/L relay—AF400 and AF460 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101122C02013/346ABB MOTOR PROTECTION AND CONTROL72 2.83"210 8.27"40 1.57"22.50.89"11.5 0.45"273 10.75"ø12.50.49"ø6.50.26"AF580 and AF750242 9.53"48.5 1.91"6 0.24"283 11.14"72 2.83"249 9.8"M6 1/4-20 UNCAF580 and AF750-30-11—AF580 and AF750 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101122C0201 ABB MOTOR PROTECTION AND CONTROL 3/347210 8.27"105 4.13"11.50.45"35.51.4"483 19.02"ø13 0.51"72 2.83"40 1.57"22.50.89"AF580 and AF750-30-11 + LX750 terminal extension242 9.53"6 0.24"43 1.69"9.6 0.38"141.5 5.57"—AF580 and AF750 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101122C02013/348ABB MOTOR PROTECTION AND CONTROL245 9.65"11 0.43"351.38"483 19.02"ø13 0.51"92 3.62"40 1.57"AF580 and AF750-30-11 + LW750 terminal enlargement242 9.53"6 0.24"43 1.69"9.6 0.38"141.5 5.57"—AF580 and AF750 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101122C0201 ABB MOTOR PROTECTION AND CONTROL 3/349210 8.27"40 1.57"72 2.83"72 2.83"466.6 18.37"11.5 0.45"11.50.45"ø12.50.49"247 9.72"40 1.57"83 3.27"83 3.27"ø12.5 0.49"AF580 and AF750-30-11 + EF750 electronic O/L relay242 9.53"48.5 1.91"6 0.24"188 7.4"60.5 2.38"5 0.2"471.5 18.56"5 0.2"5 0.2"249 9.8"M6 1/4-20 UNC82 3.23"80 3.15"79 3.11"72 2.83"M6 1/4-20 UNCAF580 and AF750 + EF750 electronic O/L relay—AF580 and AF750 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101122C02013/350ABB MOTOR PROTECTION AND CONTROL723025273E2041D450ø12.5E2043D249(M6)24072(M6)E2042D242283648.5—AF580 and AF750 3-pole contactorsDimensionsMain dimensions mm, inchesAF580 and AF750+ VM 750H mechanical interlock unitAF580 and AF750-30-11+ VM 750H mechanical interlock unit03
1SFC101136C0201 ABB MOTOR PROTECTION AND CONTROL 3/351AF1250AF1250-30-11242 9.53"46.58 0.31"18.3"1SFC101125F000172 2.83"249 9.8"M6 1/4-20 UNC1SFC101130F000150 1.97"72 2.83"72 2.83"210 8.27"344 13.54"313 12.32"263 10.35"72 2.83"ø 7 0.28"ø13 0.51"271.06"1SFC101124F0001249 9.8"—AF1250 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101136C02013/352ABB MOTOR PROTECTION AND CONTROLAF1250-30-11 + LW1250 terminal enlargement72 2.83"53.8 2.12"50 1.97"95 3.74"240 9.45"95 3.74"341.34" 263 10.35"249 9.8"15 0.59"443 17.44"479 18.86"ø13 0.51"1SFC101131F000110 0.39"37 1.46" 242 9.53"1SFC101132F0001—AF1250 3-pole contactorsDimensionsMain dimensions mm, inches03
1SFC101123C0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/353—AF1350, AF1650, AF2050 and AF2850 3-pole contactorsDimensionsMain dimensions mm, inchesAF1350, AF1650, AF2050-30-11AF1350, AF1650, AF2050AF2850-30-11AF2850136 5.35"M8 5/16-18 UMC312 12.28"136 5.35"M8 5/16-18 UMC312 12.28"136 5.35"136 5.35"80 136 5.35"ø9 0.35"438 17.24"392 15.43"312 12.28"47 1.85"40 1.57"10 0.39"244 9.61"3.15"3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"101136 5.35"136 5.35"80 136 5.35"ø9 0.35"438 17.24"392 15.43"312 12.28"47 1.85"40 1.57"10 0.39"244 9.61"3.15"3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"101136 5.35"136 5.35"80 136 5.35"ø9 0.35"438 17.24"422 16.61"312 12.28" 53 2.09"25 0.98"244 9.61"3.15"AF2650401.57"40 1.57"17 0.67"ø 130.51"3.98"10140 1.57"136 5.35"136 5.35"80 136 5.35"ø9 0.35"438 17.24"422 16.61"312 12.28" 53 2.09"25 0.98"244 9.61"3.15"AF2650401.57"40 1.57"17 0.67"ø 130.51"3.98"10140 1.57"03
1SFC101123C0201 - Rev. B3/354ABB MOTOR PROTECTION AND CONTROLM8 5/16-18 UMC312 12.28"305 12.01"1365.35"1365.35"1365.35"1365.35"879 34.61"441 17.36"10 0.39"25 0.98"263.5 10.37"66.5 2.62"263.5 10.37"72.5 2.85"—AF1350, AF1650, AF2050 and AF2850 3-pole contactorsDimensionsMain dimensions mm, inchesAF1350, AF1650, AF2050, AF2850 + VM 1650H mechanical interlock unitAF1350, AF1650, AF2050, AF2850-30-11 + VM 1650H mechanical interlock unitAF1350, AF1650, AF2050AF2850312 12.28"1365.35"395 15.55"933.66"170 6.69"M6 1/4-20 UNCM8 5/16-18 UNC438 17.24"244 9.61"10 0.39"47 1.85"20 0.79"90 3.54"10 0.39"10 0.39"17 0.67"13 0.51"27 1.06"40 1.57"30 1.18"252 9.92"80 3.15"136 5.35"136 5.35"425 16.73"674 26.54"AF1350 and AF1650-30-11+ EF1250DU-1250 electronic O/L relay03
ABB PUSH-IN SPRING MOTOR STARTING SOLUTION 3551SBC100412S0201—AF09..K, AF12..K, AF16..K 3-pole contactors - with Push-in Spring terminalsDimensionsMain dimensions mm, inchesAF09..K, AF12..K, AF16..K+ CA4..K 4-pole auxiliary contact block45 1.77"82 3.22"10.5 0.41"71 2.80"110.5 4.35"5.5 0.22"5.5 0.22"35mm EN/EC 6071510 0.39"45 1.77"AF09..K, AF12..K, AF16..K+ TEF4S electronic timer45 1.77"82 3.22"10.5 0.41"71 2.80"132.5 5.22"5.5 0.22"5.5 0.22"35mm EN/EC 6071510 0.39"41.5 1.63"AF09..K, AF12..K, AF16..K+ CA4..K 1-pole auxiliary contact block45 1.77"82 3.22"10.5 0.41"71 2.80"110.5 4.35"5.5 0.22"5.5 0.22"35mm EN/EC 6071510 0.39"45 1.77"AF09..K, AF12..K, AF16..K+ CAL4-11K 2-pole auxiliary contact block45 1.77"12 0.47"72 2.83"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22"AF09..K, AF12..K, AF16..K45 1.77"82 3.22"10.5 0.41"71 2.80"77 3.03"5.5 0.22"35mm EN/EC 6071510 0.39"5.5 0.22"AF09..K, AF12..K, AF16..K45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCNote: For AF09..K ... AF16..K contactors, lateral distance to grounded component 2 mm 0.08" min24 V DC operated contactor (coil 30) depth + 20 mm (0.79").03
356ABB PUSH-IN SPRING MOTOR STARTING SOLUTION1SBC100423S0201—AF26..K, AF30..K, AF38..K 3-pole contactors - with Push-in Spring terminalsDimensionsMain dimensions mm, inchesAF26..K, AF30..K, AF38..K+ CA4..K 4-pole auxiliary contact block45 1.77"82 3.22"10.5 0.41"80 3.15"119.5 4.70"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59"45 1.77"AF26..K, AF30..K, AF38..K+ TEF4S electronic timer82 3.22"10.5 0.41"45 1.77"80 3.15"141.5 5.57"41.5 1.63"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59"AF26..K, AF30..K, AF38..K+ CA4..K 1-pole auxiliary contact block82 3.22"10.5 0.41"45 1.77"80 3.15"119.5 4.70"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59"45 1.77"AF26..K, AF30..K, AF38..K+ CAL4-11K 2-pole auxiliary contact block12 0.47"72 2.83"82 3.22"10.5 0.41"45 1.77"80 3.15"86 3.39"5.5 0.22"35mm EN/EC 6071515 0.59"5.5 0.22"AF26..K, AF30..K, AF38..K82 3.22"10.5 0.41"45 1.77"80 3.15"86 3.39"5.5 0.22"5.5 0.22"35mm EN/EC 6071515 0.59"AF26..K, AF30..K, AF38..K45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCNote: For AF26..K ... AF38..K contactors, lateral distance to grounded component 2 mm 0.08" min24 V DC operated contactor (coil 30) depth + 20 mm (0.79").03
1SBC101485S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/35745 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC—AF09, AF16 4-pole contactorsMain dimensions mm, inches (1)AF09, AF1645 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF09, AF1645 1.77"80 3.15"6 0.24"43 1.69"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 607155.5 0.22"10 0.39"AF09, AF16+ CA4, CC4 1-pole auxiliary contact block45 1.77"12 0.47"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"AF09, AF16+ CAL4-11 2-pole auxiliary contact blockAF09, AF16+ CA4 4-pole auxiliary contact block45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"AF09, AF16+ CAT4 2-pole auxiliary contact and coil terminal block45 1.77"80 3.15"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"(1) Note: contactor lateral distance to grounded component 2 mm 0.08" min.24 V DC operated contactor (coil 30) depth + 20 mm 0.79".03
1SBC101485S0201 - Rev. B3/358ABB MOTOR PROTECTION AND CONTROL45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC—AF09, AF16 4-pole contactorsMain dimensions mm, inches (1)AF09, AF16+ TEF4 electronic timerAF09, AF16AF09..-40-00, AF16..-40-00+ VEM4 mechanical and electrical interlock setAF09..-40-00, AF16..-40-00+ VEM4 mechanical and electrical interlock set90 3.54"91.5 3.60"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"91.5 3.60"102.5 4.04"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC(1) Note: contactor lateral distance to grounded component 2 mm 0.08" min.24 V DC operated contactor (coil 30) depth + 20 mm 0.79".45 1.77"80 3.15"6 0.24"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"1.1 0.04"5.5 0.22"133.5 5.26"40.5 1.59"03
1SBC101486S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/35935 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC35 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"35 mm EN/IEC 607155.5 0.22"95 3.74"134.5 5.30"10 0.39"43 1.69"5.5 0.22"45 1.77"12 0.47"80 3.15"6 0.24"35 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 mm EN/IEC 607155.5 0.22"95 3.74"134.5 5.30"10 0.39"43 1.69"5.5 0.22"45 1.77"80 3.15"35 mm EN/IEC 607155.5 0.22"95 3.74"126.5 4.98"10 0.39"5.5 0.22"43 1.69"—AF26, AF38 4-pole contactorsDimensionsMain dimensions mm, inchesAF26, AF38AF26, AF38+ CA4, CC4 1-pole auxiliary contact blockAF26, AF38AF26, AF38+ CAL4-11 2-pole auxiliary contact blockAF26, AF38+ CAT4 2-pole auxiliary contact and coil terminal blockAF26, AF38+ CA4 4-pole auxiliary contact blockNote: For AF26 and AF38 contactors, lateral distance to grounded component 2 mm 0.08" min.03
1SBC101486S0201 - Rev. A3/360ABB MOTOR PROTECTION AND CONTROL90 3.54"91.5 3.60"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC35 mm EN/IEC 607155.5 0.22"95 3.74"126.5 4.98"10 0.39"5.5 0.22"43 1.69"90 3.54"91.5 3.60"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC35 mm EN/IEC 607155.5 0.22"95 3.74"126.5 4.98"10 0.39"5.5 0.22"43 1.69"(1) Note: For AF26 and AF38 contactors, lateral distance to grounded component 2 mm 0.08" min.—AF26, AF38 4-pole contactorsDimensionsMain dimensions mm, inches (1)AF26..-40-00, AF38..-40-00+ VEM4 mechanical and electrical interlock setAF26..-40-00, AF38..-40-00+ VEM4 mechanical and electrical interlock setAF26, AF38+ TEF4 electronic timerAF26, AF3835 mm EN/IEC 607155.5 0.22"95 3.74"10 0.39"5.5 0.22"157.5 6.20"45 1.77"80 3.15"6 0.24"40.5 1.59"1.1 0.04"35 mm EN/IEC 607155.5 0.22"95 3.74"101 3.98"10 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC03
1SBC101977S02011SBC101977S0201 ABB MOTOR PROTECTION AND CONTROL 3/361—AF40, AF52 4-pole contactorsDimensionsMain dimensions mm, inchesAF40, AF52AF40, AF526 0.24"119.5 4.70"70 2.76"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715113.5 4.47"5.5 0.22"ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"AF40, AF52+ CA4 4-pole auxiliary contact block43 1.69"100.39"5.5 0.22"7 0.28"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"70 2.76"113.5 4.47"147 5.79"5.5 0.22"AF40, AF52+ CAT4 2-pole auxiliary contact and coil terminal blockAF40, AF52+ CA4, CC4 1-pole auxiliary contact blockAF40, AF52 + CAL4-11 2-pole auxiliary contact block7 0.28"100.39"5.5 0.22"43 1.69"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"70 2.76"147 5.79"113.5 4.47"6 0.24"119.5 4.70"5.5 0.22"70 2.76"10 0.39"12 0.47"7 0.28"35 x 15 mm EN/IEC 60715113.5 4.47"43 1.69"100.39"5.5 0.22"7 0.28"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"70 2.76"113.5 4.47"139 5.47"5.5 0.22"03
1SBC101977S02013/362ABB MOTOR PROTECTION AND CONTROLAF40, AF52ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"AF40, AF52+ TEF4 electronic timer—AF40, AF52 4-pole contactorsDimensionsMain dimensions mm, inches100.39"5.5 0.22"7 0.28"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"70 2.76"113.5 4.47"169.7 6.68"5.5 0.22"1.1 0.04"40.5 1.59"7 0.28"10 0.39"5.5 0.22"113.5 4.47"6 0.24"119.5 4.70"140 5.51"5.5 0.22"5 0.20"4.6 0.18"M6 ¼-20 UNC2 xø 6.4 0.25"110 4.33"100 3.94"130 5.12"AF40, AF52+ VM96-4 mechanical interlock unitAF40, AF52+ VM96-4 mechanical interlock unit03
1SBC101978S0201 ABB MOTOR PROTECTION AND CONTROL 3/3631SBC101978S0201—AF80 4-pole contactorsDimensionsMain dimensions mm, inchesAF80AF806 0.24"119.5 4.70"90 3.54"116 4.57"7 0.28"10 0.39"5.5 0.22"35 x 15 mm EN/IEC 60715ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x80 3.15"AF80+ CA4 4-pole auxiliary contact block43 1.69"116 4.57"100.39"5.5 0.22"149 5.87"7 0.28"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"90 3.54"5.50.22"AF80+ TEF4 Electronic timerAF80+ CA4, CC4 1-pole auxiliary contact blockAF80 + CAL4-11 2-pole auxiliary contact block116 4.57"7 0.28"100.39"5.5 0.22"149 5.87"43 1.69"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"90 3.54"6 0.24"119.5 4.70"5.5 0.22"116 4.57"10 0.39"12 0.47"7 0.28"35 x 15 mm EN/IEC 6071590 3.54"116 4.57"100.39"5.5 0.22"7 0.28"35 x 15 mm EN/IEC 607156 0.24"119.5 4.70"90 3.54"171.8 6.76"5.5 0.22"1.1 0.04"40.5 1.59"03
1SBC101978S02013/364 ABB MOTOR PROTECTION AND CONTROLAF80+ CA4, CC4 1-pole auxiliary contact blockAF80+ VM96-4 mechanical interlock unit—AF80 4-pole contactorsDimensionsMain dimensions mm, inches116 4.57"7 0.28"10 0.39"5.5 0.22"6 0.24"119.5 4.70"180 7.09"5 0.20"4.6 0.18"M6 ¼-20 UNC2 xø 6.4 0.25"110 4.33"100 3.94"170 6.69"03
1SFC101228C0201 ABB MOTOR PROTECTION AND CONTROL 3/3651SFC101228C0201 - Rev. AAF116, AF140-40-11 + VM19 mechanical interlocking unit150 5.91"128 5.04"240 9.45"AF116, AF140 + VM19 mechanical interlocking unit100 3.94"60 2.36"60 2.36"M4 8-32 UNC60 2.36"150 5.91"128 5.04"240 9.45"—AF116, AF140 4-pole contactorsDimensionsMain dimensions mm, inchesAF116, AF140-40-00B + CAL19 2-pole auxiliary contact blockAF116, AF140-40-11BASECTION A-A 55.5 2.18"19.5 0.77"150 5.91"30 1.18"10 0.39"128 5.04"120 4.72"AF116, AF140-40-00 + CAL19 2-pole auxiliary contact blockAF116, AF140-40-11AF116, AF140-40-..(B)SECTION A-A 55.5 0.22"19.5 4.96"30 1.18"A150 5.91"10 0.39"120 4.72"128 5.04"100 3.94"M4 8-32 UNC60 2.36"03
1SFC101229C0201 - Rev. A3/366ABB MOTOR PROTECTION AND CONTROLAF190, AF205-40-11+ LW205-40 terminal enlargement45 1.77"319 12.56"36 1.42"10 0.39"170 6.69"ø 10.5 0.41"20 0.79"152.5 6.00"5 0.20"40.5 1.59"—AF190, AF205 4-pole contactorsDimensionsMain dimensions mm, inchesAF190, AF205-40-00 + CAL19 2-pole auxiliary contact blockAF190, AF205-40-11AF190, AF205-40Aø 8.5 0.33"35 1.38"196 7.72"10 0.39"83.5 3.29"35.5 1.40"5 0.20"29.5 1.16"SECTION A-A 140 5.51"152.5 6.00"165 6.50"M5 10-24 UNC4 X70 2.76"03
1SFC101229C0201 ABB MOTOR PROTECTION AND CONTROL 3/3671SFC101229C0201 - Rev. AMain dimensions mm, inchesAF190, AF205-40-11 + VM19 mechanical interlocking unitAF190, AF205 + VM19 mechanical interlocking unit165 6.50"70 2.76"M5 10-24 UNC4 X70 2.76"70 2.76"152.5 6.00"196 7.72"280 11.02"—AF190, AF205 4-pole contactorsDimensions03
1SFC101230C0201 - Rev. A3/368ABB MOTOR PROTECTION AND CONTROL—AF265, AF305, AF370 4-pole contactorsDimensionsMain dimensions mm, inchesAF265, AF305, AF370-40-00 + CAL19 2-pole auxiliary contact blockAF265, AF305, AF370-40-1119.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"183.75 7.23"AF265, AF305, AF370187 7.36"M5 10-24 UNC4 X87.5 3.44"AF265, AF305, AF370-40-11 + LW370-40 terminal enlargement62 2.44"404.4 15.92"36 1.42"226 8.90"25 0.98"ø 10.5 0.41"12.5 0.49"5 0.20"180.4 7.10"40.7 1.60"19.5 0.77"ø 10.5 0.41"43.75 1.72"180 7.09"94.7 3.73"225 8.86"35.5 1.40"5 0.20"33.4 1.31"A10 0.39"183.75 7.23"03
1SFC101230C0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/369Main dimensions mm, inchesAF265, AF305, AF370-40-11 + VM19 mechanical interlocking unitAF265, AF305, AF370 + VM19 mechanical interlocking unit225 8.86"180 7.09"367.5 14.47"187 7.36"87.5 3.44"M5 10-24 UNC4 X87.5 3.44"97 3.82"—AF265, AF305, AF370 4-pole contactorsDimensions03
1SBC101651S0201 - Rev. A3/370 ABB MOTOR PROTECTION AND CONTROL—EK550, EK1000 4-pole contactors AC operatedDimensionsMain dimensions mm, inches1) Dimension for extra auxiliary contact block2) Screw, nut and washer by-packed3) Min. distance to uninsulated wall4) Damping elements are included5) Earthing screwa) Min. dim Makes distance F1 = 70b) Includes space for three auxiliary contact blocks between the contactorsc) Includes space for four auxiliary contact blocks between the contactors1/L13/L25/L37/L42/T14/T26/T38/T4299 11.77"200.79"67 2.64"40 1.57"244 9.61"270 10.63"110.43"1) ø11 0.43"2)110.43"1)EK10008 0.31"139.5 5.49"225.5 8.88"23 0.91"4)223 8.78"40 1.57"3)M103/8-16 UNC5)F1200 7.87"220 8.66"M6 1/4-20 UNC--271 10.67"a)282 11.1"b)293 11.54"c)EK1000200 7.87"ø 6.20.24"220 8.66"40 1.57"139.5 5.49"6 0.24"225.5 8.88"230.91"223 8.78"M103/8-16 UNC4)5)3)270 10.63"110.43"110.43"244 9.61"67 2.64"250.98"272 10.71"12.5 0.49"1)1)ø 11 0.43"1/L13/L25/L37/L42/T14/T26/T38/T42)EK55003
1SBC101653S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/371—EK550, EK1000 4-pole contactors DC operatedDimensionsMain dimensions mm, inches1) Dimension for extra auxiliary contact block2) Screw, nut and washer by-packed3) Min. distance to uninsulated wall4) Damping elements are included5) Earthing screwa) Min. dim.b) Includes space for two auxiliary contact blocks and the dc-unit between the contactors139.5 5.49"6 0.24"225.5 8.88"230.91"223 8.78"4)40 1.57"3)M103/8-16 UNC5)200 7.87"ø 6.20.24"220 8.66"8 0.31"139.5 5.49"225.5 8.88"23 0.91"4)223 8.78"401.57"3)M103/8-16 UNC5)270 10.63"110.43"244 9.61"67 2.64"250.98"272 10.71"12.5 0.49"1)1/L13/L25/L37/L42/T14/T26/T38/T4296 11.65"ø 11 0.43"2)EK5501/L13/L25/L37/L42/T14/T26/T38/T4299 11.77"200.79"67 2.64"40 1.57"244 9.61"270 10.63"ø 11 0.43"2)296 11.65"110.43"1)EK1000F1200 7.87"220 8.66"M6 1/4-20 UNC297 11.69"-a)308 12.13"b)EK100003
1SBC101985S0201—GA75 ... GAF2050 contactorsTerminal marking and positioningGAE75 contactors - DC operatedStandard devices without addition of auxiliary contactsGAE75-10-11GAE75-10-11GAE75-10-00GAE75-10-00A1A2CDL51L1 +2T1 –A336X35XA1A213X21X14X22XNONCNONCCDL51L1 +2T1 –A336X35XA11L1 +A22T1 –A335X36X13X14X21X22XA1A2A335X36X1L1 +2T1 –GA75-10-11GA75-10-11GA75-10-00GA75-10-00GA75 contactors - AC operatedStandard devices without addition of auxiliary contactsA11L1 +2T1 –A2A2A11L1 +2T1 –A213X21X14X22XNONCNONCA2A11L1 +A22T1 –A11L1 +13X14X21X22XA22T1 –GAF185 ... GAF2050-10-11GAF185 ... GAF2050-10-11GAF185 ... GAF2050 contactors - AC / DC operated+Device equipped withpermmanent magnetsIEC 60947-4-1Ui = 1000V DCIth=2050AUe = 1000V DC1G1129Ie DC-1 = 2050AGAF2050-10EN 60947-4-1All 3 poles must beconnected in seriesConnection bars are sold separatelyA11L1 +13X14X21X22XA22T1 –033/372ABB MOTOR PROTECTION AND CONTROL
1SBC101491S0201 ABB MOTOR PROTECTION AND CONTROL 3/37350.2"50.2"60 2.36"90 3.54"ø 6.2 0.24"M6 1/4-20 UNC100 3.94"50.2"50.2"60 2.36"90 3.54"ø 6.2 0.24"M6 1/4-20 UNC100 3.94"100.39"6.50.26"60.24"10 0.39"40.16"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"72 2.83"72 2.83"100.39"6.50.26"60.24"10 0.39"40.16"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"72 2.83"72 2.83"12 0.47"110 4.33"70 2.76"110.43"11 0.43"GA75-10-11GA75GAE75-10-11GAE7582 3.23"12 0.47"110.43"110 4.33"11 0.43"70 2.76"110 4.33"110.43"110.43"GA75-10-0082 3.23"110.43"110 4.33"110.43"GAE75-10-00—GA75, GAE75 1-pole contactor DimensionsMain dimensions mm, inches03
1SFC101180C02013/374ABB MOTOR PROTECTION AND CONTROLGAF185-30-11GAF185-30-11GAF300-30-11GAF300-30-11ø 8.5 0.33"120.47"17.50.69"105 4.13"111.5 4.39"351.38"10 0.39"187 7.36"160 6.3"35.51.4"196 7.72"5 0.2"M5 10-24 UNC351.38"165 6.5"43.75 1.72"ø 10.20.4"219 8.62"14 0.55"140 5.51"120.47"17.5 0.69"5 0.2"180.5 7.11"35.5 1.4"227 8.94"M5 10-24 UNC43.75 1.72"187 7.36"—GAF185, GAF300 3-pole contactor DimensionsMain dimensions mm, inches03
1SFC101181C0201 ABB MOTOR PROTECTION AND CONTROL 3/375GAF460-30-1163 2.48"186 7.32"25 0.98"22.5 0.89"11.5 0.45"268 10.55"ø10.5 0.41"ø6.5 0.26"216 8.5"48.5 1.91"6 0.24"278 10.94"63 2.48"248 9.76"M5 10-24 UNC—GAF460 3-pole contactor DimensionsMain dimensions mm, inches03
1SFC101182C02013/376ABB MOTOR PROTECTION AND CONTROLGAF750-30-11242 9.53"48.5 1.91"6 0.24"283 11.14"72 2.83"249 9.8"M6 1/4-20 UNC72 2.83"210 8.27"40 1.57"22.50.89"11.5 0.45"273 10.75"ø12.50.49"ø6.50.26"—GAF750 3-pole contactorDimensionsMain dimensions mm, inches03
1SFC101183C0201 ABB MOTOR PROTECTION AND CONTROL 3/377GAF1250-30-11242 9.53"46.58 0.31"18.3"1SFC101125F000172 2.83"249 9.8"M6 1/4-20 UNC1SFC101130F000150 1.97"72 2.83"72 2.83"210 8.27"344 13.54"313 12.32"263 10.35"72 2.83"ø 7 0.28"ø13 0.51"271.06"1SFC101124F0001249 9.8"—GAF1250 3-pole contactor DimensionsMain dimensions mm, inches03
1SFC101184C0201 - Rev. A3/378ABB MOTOR PROTECTION AND CONTROLGAF1650, GAF2050-30-11136 5.35"M8 5/16-18 UMC312 12.28"136 5.35"136 5.35"80 136 5.35"ø9 0.35"101 438 17.24"392 15.43"312 12.28"47 1.85"10 0.39"244 9.61"3.15"3.98"40 1.57"27 13 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"136 5.35"136 5.35"80136 5.35"ø9 0.35"101438 17.24"392 15.43"312 12.28"47 1.85"10 0.39"244 9.61"3.15"3.98"40 1.57"2713 0.51"30 1.18"17 0.67"10 0.39" 1.06"AF1350, AF1650AF2050401.57"17 0.67"0.51"ø 130.51"1330 1.18"10 0.39"GAF1650GAF2050—GAF1650, GAF2050 3-pole contactor DimensionsMain dimensions mm, inches03
1SBC101575S0201 ABB MOTOR PROTECTION AND CONTROL 3/379—UA..RA 3-pole contactors for capacitor switchingUnlimited peak current ÎMain dimensions mm, inches4.50.18"ø 4.5 0.18"4.50.18"35 1.38"60 2.36"50 1.97"M4 8-32 UNCø 4.2 0.17"4.50.18"4.50.18"45 1.77"70 2.76"80 3.15"M4 8-32 UNCø 4.2 0.17"4.50.18"4.50.18"45 1.77"70 2.76"80 3.15"M4 8-32 UNC50.2"50.2"60 2.36"90 3.54"ø 6.2 0.24"M6 1/4-20 UNC100 3.94"68 2.68"47 1.85"107 4.21"5.5 0.22"4 0.16"35 mm EN/IEC 60715+10+.394"120 4.72"44 1.73"74 2.91"UA16..RA54 2.13"90 3.54"UA26..RA47 1.85"87.3 3.44"126.3 4.97"9 0.35"4 0.16"35 mm EN/IEC 60715+10120 4.72"+.394"54 2.13"90 3.54"UA30..RA102 4.02"9 0.35"4 0.16"47 1.85"130 5.12"+10+.394"141 5.55"35 mm EN/IEC 607156 0.24"10 0.39"4 0.16"75 mm EN/IEC 6071535 mm x 15 EN/IEC 60715140.4 5.53"47 1.85"+10+10"150 5.91"101.5 4"70 2.76"110 4.33"114 4.49"UA50..RA, UA63..RA, UA75..RA03
1SBC101575S02013/380ABB MOTOR PROTECTION AND CONTROL—UA..RA 3-pole contactors for capacitor switchingUnlimited peak current ÎMain dimensions mm, inches47 1.85"+10+10"170 6.69"114.4 4.5"6 0.24"75 mm EN/IEC 6071510 0.39"155.6 6.13"155.3 6.11"90 3.54"148 5.83"UA95..RA, UA110..RA126 4.96"78 3.07"ø 6.2 0.24"M6 1/4-20 UNC136 5.35"6 0.24"6 0.24"03
1SBC101572S0201 ABB MOTOR PROTECTION AND CONTROL 3/381—UA.. 3-pole contactors for capacitor switchingDimensionsMain dimensions mm, inches68 2.68"74 2.91"5.50.22"40.16"10 0.39"35 mm EN/IEC 6071544 1.73"74 2.91"UA16ø 4.2 0.17"4.50.18"4.50.18"45 1.77"70 2.76"80 3.15"M4 8-32 UNCUA26, UA30 drilling plan50.2"50.2"60 2.36"90 3.54"ø 6.2 0.24"M6 1/4-20 UNC100 3.94"Drilling plan90 3.54"148 5.83"UA95, UA110-30-00120.47"90 3.54"148 5.83"74 2.91"UA95, UA110-30-11123.5 4.86"60.24"20 0.79"10 0.39"6.5 0.26"126 4.96"78 3.07"ø 6.2 0.24"M6 1/4-20 UNC136 5.35"6 0.24"6 0.24"Drilling plan70 2.76"110 4.33"UA50, UA63, UA75-30-0070 2.76"120.47"110 4.33"74 2.91"UA50, UA63, UA75-30-116.5 0.26"6 0.24"10 0.39"40.16"10 0.39"75 mm EN/IEC 6071535 mm x15 EN/IEC 60715108 4.25"4.50.18"ø 4.5 0.18"4.50.18"35 1.38"60 2.36"50 1.97"M4 8-32 UNCUA16 drilling plan93.6 3.69"9 0.35"6.3 0.25"4 0.16"10 0.39"35 mm EN/IEC 6071554 2.13"90 3.54"UA2654 2.13"90 3.54"UA30108.3 4.26"9 0.35"6.3 0.25"4 0.16"10 0.39"35 mm EN/IEC 6071503
1SBC101583S0201 - Rev. B3/382ABB MOTOR PROTECTION AND CONTROL—NF contactor relaysDimensionsMain dimensions mm, inches (1)N F. . 2 2 E , N F. . 3 1E , N F. . 4 0 E45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCNF45 1.77"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCN F. . 2 2 E , N F. . 3 1E , N F. . 4 0 E+ CA4, CC4 1-pole auxiliary contact block45 1.77"80 3.15"6 0.24"43 1.69"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 607155.5 0.22"10 0.39"N F. . 2 2 E , N F. . 3 1E , N F. . 4 0 E+ CAL4-11 2-pole auxiliary contact block45 1.77"12 0.47"80 3.15"6 0.24"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"45 1.77"80 3.15"6 0.24"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"1.1 0.04"5.5 0.22"133.5 5.26"40.5 1.59"N F. . 2 2 E , N F. . 3 1E , N F. . 4 0 E+ TEF4 electronic timerN F. . 2 2 E , N F. . 3 1E , N F. . 4 0 E+ CA4 4-pole auxiliary contact block45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"N F. . 4 4 E , N F. . 53 E , N F. .6 2 E , N F. .7 1E , N F. . 8 0 E , N F. . 3 3/1 1 , N F. . 51/1 135 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"80 3.15"6 0.24"110.5 4.35"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"5.5 0.22"43 1.69"(1) Note: contactor relay lateral distance to grounded component 2 mm 0.08" min.24 V DC operated contactor relay (coil 30) depth + 20 mm 0.79".03
ABB MOTOR PROTECTION AND CONTROL 3/383—Notes03
3/384ABB MOTOR PROTECTION AND CONTROL
—Other contactor application data Contactor selection3/386 Control of three-phase slip-ring motors3/388 Autotransformer starters3/389 Three-phase transformer switching3/391 Lighting circuit switching3/400 Parallel connection of main poles3/401 Temporary or intermittent duty3/402 Influence of the length of conductors used in contactor control circuit 3/404 Voltage code table3/409 Questionnaire for product specifications— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R1310 ABB MOTOR PROTECTION AND CONTROL 3/38503
1SBC101969S0201 - Rev. B3/386ABB MOTOR PROTECTION AND CONTROL—Control of three-phase slip-ring motorsContactor selection GeneralThree kinds of contactors are used to control three-phase slip-ring motors: the stator contactor, the acceleration contactor(s) and the rotor short-circuit contactor. Refer to the diagram opposite. The selection tables below concern complete smooth starting, excluding specific cases, such as: intermittent operation, regenera-tive current, controlled slipping, etc. for which you need to consult our specialised departments. The starting and breaking technical data for slip-ring motors are defined in standard IEC 60947-4-1 in the AC-2 utilization category. The load factor is defined by the equation:Operating cycleL.F. (%) = x 100Cycle time (Operating cycle + Rest cycle) Stator contactorClosing of the starting current, conditioned by the value of the rotor resistances: it may reach 1.5 to 4 times rated motor operational current. Breaking of the rated operational current, or of the starting current, with possible regenerative current. The following table gives the permissible values of the Ie / AC-2 rated operational stator current, as a function of load factor. Temperature of 60 °C for AF09 ... AF370 and 55 °C for AF400 ... AF1650 maximum near the contactor. Maximum switching frequency and electrical durability in AC-2 category: see "Technical data".Contactor typesAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Load factor15 % Ie / AC-2 A 1824335264767910612415418425 % Ie / AC-2 A 152031445465689011113616340 % Ie / AC-2 A 13172638465558779411613960 % Ie / AC-2 A 11142231384648647896115S7 acc. to IEC 60034-1: periodical continuous duty with electrical breaking A 912182632384053658096Acceleration contactorsThe sizing of these contactors is based on the AC-1 rated operational current (see "Technical data") that we recall below for the max-imum ambient temperature of 60 °C for AF09 to AF370 and 55 °C for AF400 to AF1650. The table below lists the factors to be applied to the AC-1 current of the contactors in order to obtain the maximal permissible value of the rotor current after contactor closing for star connection. If delta connection is used, increase by 50 % this current. This table takes into account the number of cycles an hour (without inching) and the current flow time per cycle, in the contactor.Number of cycles an hour 13612203060120Current flow time per cycle Factors applicable to Ie / AC-1 5 s 5.24.94.74.34.03.73.42.8 10 s 3.83.63.43.13.02.82.62.2 20 s 2.82.72.62.52.42.22.01.6 30 s 2.42.32.22.12.11.91.7- 40 s 2.22.12.01.91.91.71.5- 60 s 1.91.81.81.71.71.5--Contactors AF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Rated operational current Ie / AC-1 for air temperature near the contactor ≤ 60 °C A 252830404242608090100105Rotor short-circuit contactorThe duty of this contactor is characterized by small closing stresses. The decisive factor is the thermal stress. Delta connection of the contactor is considered (reduce currents by 35 % if star connection is used). The following table gives the permissible values of the rated operational rotor current, as a function of load factor. Temperature: 60 °C for AF09 to AF370 and 55 °C for AF400 to AF1650 maximum near the contactor.Contactor typesAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Load factor15 % Ie A 63717610210710715220322825426625 % Ie A 57646992969613718320622924140 % Ie A 49555978828211715717619620660 % Ie A 434851687272103137154171180S7 acc. to IEC 60034-1: periodical continuous duty with electrical breaking A36414458616187116131145152Rated operational rotor voltage: -Maximum values for starting and breakingV1380 (1600 in star connection)2000 (2300 in star connection) -Maximum values for starting and electrical brakingV690 (730 in star connection)690 (730 in star connection)03
1SBC101969S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 3/387Example of a three-stroke starter•The first stroke corresponds to energization of the motor by the stator contactor: all the resistances are operational in the rotor circuit•At the second stroke, the acceleration contactor short-circuits the first resistance stack•At the third stroke, the rotor short-circuit contactor isactivated by eliminating the last resistance stack, thus com-pleting the starting period.Stator contactorAccelerationcontactorRotor short-circuitcontactor R2R1M3Contactor typesAF116AF140AF190AF205AF265AF305AF370AF400AF460AF580AF750AF1350AF1650Load factor15 % Ie / AC-2 A 220335360425530625750850950115015001720210025 % Ie / AC-2 A 18527030035044051562068078097512501430175040 % Ie / AC-2 A 15021525030037043051558065080010501200147060 % Ie / AC-2 A 13518022025531537043048055070090010301250S7 acc. to IEC 60034-1: periodical continuous duty with electrical breaking A 1161401902102653053704004605807508601050Contactors AF116AF140AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1350AF1650Rated operational current Ie / AC-1for air temperature near the contactor ≤ 60 °C (AF116-AF370) ≤ 55 °C (AF400-AF1650) A 14517525030035040050050060070080011501450Contactor typesAF116AF140AF190AF205AF265AF305AF370AF400 AF460AF580AF750AF1350AF1650Load factor15 % Ie A 330540580750830950105012001400165019002400280025 % Ie A 30049053065072583091510501250145016502100250040 % Ie A 2604254605756307208009501100130014501850220060 % Ie A 2303754005005756507008109751150130016501950S7 acc. to IEC 60034-1: periodical continuous duty with electrical breaking A200300350380480550640700840980115015001800Rated operational rotor voltage: -Maximum values for starting and breakingV2200 (2600 in star connection)3000 (3600 in star connection) -Maximum values for starting and electrical brakingV690 (730 in star connection)—Control of three-phase slip-ring motorsContactor selection 03
—Autotransformer startersContactor selection3/388ABB MOTOR PROTECTION AND CONTROL1SBC101699S0201 - Rev. B03GeneralAn autotransformer starter allows to start a squirel cage motor with a reduced starting current due to the reduced voltage within the accelerating duration.Unlike the star-delta wiring, this autotransformer starting method needs three wires and three terminals on the motor.At the starting period, the motor is wired to the autotrans-former taps: the star contactor "KM3" and the autotrans-former contactor "KM2" are closed, the motor is under re-duced voltage. Consequently, the torque is reduced as the square of the applied voltage. The autotransformers are generally equipped of three taps at each phase in order to adapt the starting parameters to the field requirements.When the motor reaches 80...95 % of its nominal speed, the star contactor opens. Then, the line contactor "KM1" is mak-ing and the autotransformer contactor is opening. This starting process is done without any network interruption.KM1KM2T1AutotransformerElectrical distributionKM3Selection Table (Id starting current / In nominal current < 8 - Acceleration time ≤ 20s - 30 cycles / h max.)kW motor ratings 50/60 HzContactorsKM1KM2KM3lineautotransformer taps:star220/240 V380/400 V415 V440 V690 V90 %80 %70 %60 %47.57.57.59AF16AF16AF12AF09AF09AF096.511111115AF26AF26AF16AF16AF09AF161118.518.518.522AF38AF30AF26AF26AF16AF261522303030AF52AF52AF38AF30AF26AF3018.530373737AF65AF52AF40AF30AF26AF382237454545AF80AF65AF52AF40AF30AF402545555555AF96AF80AF65AF52AF38AF523055557555AF116AF116AF80AF65AF52AF653775759075AF140AF140AF96AF80AF65AF654575759090AF146AF140AF96AF80AF65AF65559090110132AF190AF146AF116AF96AF65AF8055110110132160AF205AF190AF140AF116AF80AF9675132132160200AF265AF265AF190AF140AF96AF11690160160160250AF305AF265AF205AF190AF116AF140110200200200315AF370AF370AF265AF190AF140AF190132250250250355AF460 AF400 AF305 AF265 AF190AF205 160315355355500AF580 AF580 AF400 AF305 AF205 AF305 220400425450600AF750 AF750 AF580 AF400 AF305AF400 257475500560900AF1350 AF750 AF580 AF460 AF400 AF460 3155606006701000AF1650 AF1350 AF750 AF580 AF460 AF580
1SBC101970S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 3/389—Three-phase transformer switchingContactor selectionAC-6a Utilization category according to IEC 60947-4-1GeneralSwitching the primary of 3-phase transformers, on energization of the transformer, is characterized by high current peaks due to the magnetization phenomena. Selection TableThe tables below show the operational ratings for:• current peaks up to 20 to 30 times the transformer nominal current• maximum switching frequency of 60 operating cycles per hour• air ambient temperature ≤ 40 °C.AC / DC operated contactorsAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96Operational power at Ue: 50/60 Hz - according to AC-6a220 / 240 V kVA 4 5 6 10 13 14 15 19 21 23 25 380 / 400 V kVA 7 8 10 17 22 25 26 33 36 39 44 415 / 440 VkVA8 9 11 18 24 27 28.5 36 40 43 48 500 VkVA9 11 13 22 28 32 34.5 43 48 52 57 660 / 690 V kVA 12.5 14 18 29 37 43 45.5 57 64 68 75 Max. permissible Îpeak A 350 400 500 800 1000 1200 1250 1550 1750 1900 2100 AC / DC operated contactorsAF116AF140AF190AF205AF265AF305AF370AF400AF460AF580AF750AF1350AF1650Operational power at Ue: 50/60 Hz - according to AC-6a220 / 240 V kVA 2630424555637695100110130160190380 / 400 V kVA 4652737594108132165170190240275350415 / 440 VkVA50578080103118144180190210270325390500 VkVA606896100124143173220230250320––660 / 690 V kVA 80 90127130164188228290300310410––Max. permissible Îpeak A 2100 2400 3300 3500 4300 4900 6000 7700 8400 930012000 ––03
—Notes3/390ABB MOTOR PROTECTION AND CONTROL03
—Lighting circuit switchingContactor selectionGeneralContactor selection criteria for control of lighting circuits are as follows:• type, power rating and number of lamps• connection mode• current values on closing and in steady state• power factor• presence or not of correction capacitors.Lighting circuitsIn a given circuit, the number and power rating of lamps are defined and cannot result in overload. Only short-circuit protec-tion has to be provided. gG fuses or modular circuit-breakers will be chosen for this purpose.The lamps have very specific technical data, according to their construction type.• Incandescent lamps have a very high current on closing: more than 15 times nominal current. They do not introduce a large phase displacement between current and voltage• Fluorescent tubes are equipped with a ballast whose purpose is two-fold: contribute to ignition and limit current to nomi-nal value once steady state is reached. This ballast is a reactor that considerably lowers the power factor. It may or may not be compensated.Individual compensation(parallel compensation)Serial compensation in dual mountingSSSSelection of contactorsThe following tables indicate, for each contactor type, the maximum permissible number of lamps per phase. Air tempera-ture, near the contactor, must be limited to 60 °C. Numbers are given for a 230 V voltage distributed between phase and neu-tral: single-phase (phase + neutral) or three-phase (3 phases + neutral) distribution, lamps are wired in star connection. In the case of a three-phase supply without neutral, 230 V phase-to-phase, the permissible number of lamps per phase will be that given in the tables multiplied by 0.58.Example:120 x 100 W / 230 V incandescent lamps - 400 V three-phase network with distributed neutral.Calculate the number of lamps per phase: 120 : 3 = 40. On the 100 W line of the incandescent lamp table, contactor AF09 is limited to 38 lamps per phase, you must thus select contactor AF12 which accepts up to 43 lamps per phase.1SBC101961S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39103
—Lighting circuit switchingContactor selection AF09 ... AF146 3-pole contactorsSelection table3-pole AC / DC operated contactorsAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96AF116AF140AF146Lamp characteristicsMaximum permissible number of lamps per phaseWAμFIncandescent and halogen lampsVoltage: 220/240 V ACaccording to AC-5b600.27-6472771031291481772072332592774305195411000.45-3843466277891061241401551662583113242000.91-19212330384452616977821271541603001.37-1214152025293541465154851021075002.28-789121517212427303351616410004.55-3446781012131516253132Fluorescent lamps without compensation - Fluorescent lamps with electronic starterVoltage: 220/240 V ACaccording to AC-5a200.38-465155738492126147157184210305368384400.45-384346627177106124133155177258311324650.70-252730404550688085100114166200209800.80-212426354043607075871001451751831001.15-15161824273041485260691011221271101.20-141617232629404650586697117122Fluorescent lamps with parallel compensationVoltage: 220/240 V ACaccording to AC-5a200.185535353155168176266309325388444644778811400.265535353107123134184215230269307446538562650.427373737667683114133142166190276333348800.527333737536167921071151341532232692811000.65161616164349537386921071231782152251100.7018141414404549688085100114166200209Fluorescent lamps in dual mountingVoltage: 220/240 V ACaccording to AC-5a2 x 20 2 x 0.14 -6269751001141251712002142502854145005212 x 40 2 x 0.25 -353942566470961121201401602322802922 x 65 2 x 0.40 -212426354043607075871001451751832 x 80 2 x 0.48 -18202129333650586272831211461522 x 100 2 x 0.60 -1416172326294046505866971171222 x 110 2 x 0.65 -131516212426364346536189108112Compact fluorescent lampsVoltage: 220/240 V ACaccording to AC-5a50.045-3884334666227117771066124413331555177725783111324470.075-2332602803734264666407468009331066154718671947110.105-166185200266304333457533571666761110513331390150.135-12914415520723725935541444451859285910371081200.160-109121131175200218300350375437500725875913230.180-971081161551771942663113333884446447788111SBC101961S0201 - Rev. B3/392ABB MOTOR PROTECTION AND CONTROL03
—Lighting circuit switchingContactor selection AF190 ... AF2650 3-pole contactorsSelection table3-pole AC / DC operated contactorsAF190AF205AF265AF305AF370AF400AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650Lamp characteristicsMaximum permissible number of lamps per phaseWAμFIncandescent and halogen lampsVoltage: 220/240 V ACaccording to AC-5b600.27-704759981113013701481170421482778300932503972493563801000.45-422456589678822889102212891667180619502383296138282000.91-2092252913354074405056378248939641179146418933001.37-13915019322327029233642354759364178397312575002.28-839011613416217520225432935638547058475510004.55-424558678188101127165179193236293379Fluorescent lamps without compensation - Fluorescent lamps with electronic starterVoltage: 220/240 V ACaccording to AC-5a200.38-500539697803974105312111526197421382309282235074533400.45-42245658967882288910221289166718061950238329613828650.70-271293379436529571657829107111611254153219042461800.80-238256331381463500575725938101610971341166621531001.15-165178230265322348400504652707763933115914981101.20-15817122125430833338348362567773189411101435Fluorescent lamps with parallel compensationVoltage: 220/240 V ACaccording to AC-5a200.18510561139147216942056222225563222416745144875595874039569400.265731788101911731423153817692231288531253375412551256625650.42745248863172688195210951381178619352089255431734101800.52736539451058771276988511151442156316882063256333131000.65162923154084695696157088921154125013501650205026501100.7018271293379436529571657829107111611254153219042461Fluorescent lamps in dual mountingVoltage: 220/240 V ACaccording to AC-5a2 x 20 2 x 0.14 -679732946108913211429164320712679290231343830475961522 x 40 2 x 0.25 -38041053061074080092011601500162517552145266534452 x 65 2 x 0.40 -238256331381463500575725938101610971341166621532 x 80 2 x 0.48 -1982142763183854174796047818469141117138817942 x 100 2 x 0.60 -158171221254308333383483625677731894111014352 x 110 2 x 0.65 -14615820423528530835444657762567582510251325Compact fluorescent lampsVoltage: 220/240 V ACaccording to AC-5a50.045-422245565889677882228889102221288916667180561950023833296113827870.075-25332733353340674933533361337733100001083311700143001776722967110.105-18101952252429053524381043815524714377388357102141269016405150.135-140715191963225927412963340742965556601965007944987012759200.160-118812811656190623132500287536254688507854846703832810766230.180-105611391472169420562222255632224167451448755958740395691SBC101961S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39303
—Lighting circuit switchingContactor selection AF09 ... AF146 3-pole contactorsSelection table3-pole AC / DC operated contactorsAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96AF116AF140AF146Lamp characteristicsMaximum permissible number of lamps per phaseWAμFLow pressure sodium vapour lamps without compensationVoltage: 220/240 V AC351.4-910121515162331353942708589551.4-910121515162331353942708589902.1-67810101015202326284757591353.1-44567710141517193238401803.1-4456771014151719323840Low pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC350.62012121235363855738191100164198207550.62012121235363855738191100164198207900.92510101023242536485561661101321381350.94555518181934343657591101321381800.9455551818193434365759110132138High pressure sodium vapour lamps without compensationVoltage: 220/240 V AC1501.8-78911121218242730334554572503.0-45577711141618202733344004.4-3334557101112131822236006.2-22233357789131616100010.3-1112223445581010High pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC1501.0201212122122233343495560931121172501.53677714141522293336406275784002.54855588913171922243745476003.365333666101315161828343510006.210022233357789151819High pressure mercury vapour lamps without compensationVoltage: 220/240 V AC500.60-22252835363855738291100152190214800.80-16182126272841556168751141431601251.15-111314181920283843475279991122502.15-6679101015202325274253604003.25-44566710131516182835397005.40-223344689101117212410007.50-12222345678121517Voltage: 380/415 V AC20008.00-11222245667111416High pressure mercury vapour lamps with compensationVoltage: 220/240 V AC500.287363636757882117157176196214326407458800.438313131485153761021151271392122652981250.661020222531333450667583901381731942501.2818101113161717253438424671891004002.052567810101116212426294456637003.554034456691213151626323610004.836023344469101112192427Voltage: 380/415 V AC20005.453522334468910111721241SBC101961S0201 - Rev. B3/394ABB MOTOR PROTECTION AND CONTROL03
Selection table3-pole AC / DC operated contactorsAF190AF205AF265AF305AF370AF400AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650Lamp characteristicsMaximum permissible number of lamps per phaseWAμFLow pressure sodium vapour lamps without compensationVoltage: 220/240 V AC351.4-1151241611852252432793524554935336518091046551.4-1151241611852252432793524554935336518091046902.1-77831071231501621862353043293554345396971353.1-525673841011101261592062232412943654721803.1-52567384101110126159206223241294365472Low pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC350.620269290375432524567652822106311511243151918882440550.620269290375432524567652822106311511243151918882440900.9251791942502883493784345487087678291013125816271350.9451791942502883493784345487087678291013125816271800.945179194250288349378434548708767829101312581627High pressure sodium vapour lamps without compensationVoltage: 220/240 V AC1501.8-74801031191441561792262923133384135136632503.0-4448627186931071351751882032483083984004.4-30334249596473921191281381692102716006.2-2123303442455265859198120149192100010.3-13141821252731395155597290116High pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC1501.020152164212244296320368464600625675825102513252501.5361011091411631972132453094004174505506838834002.548616685981181281471862402502703304105306003.36546506474909711214118218920525031140210006.2100252634394852597597101109133165214High pressure mercury vapour lamps without compensationVoltage: 220/240 V AC500.60-26133338047557057066576099811881283156819482518800.80-1962492853564284284995707488919621176146118881251.15-136173198248297297347397520620669818101613132502.15-73931061331591591862122783313584375437034003.25-486170881051051231401842192372893604657005.40-293742536363748411113214317421628010007.50-21273038464653618095103125156201Voltage: 380/415 V AC20008.00-2025293643435057758996118146189High pressure mercury vapour lamps with compensationVoltage: 220/240 V AC500.28756071381410181221122114251629213825452748335941735395800.43836546453066379579592810601392165717902187271735131250.6610238302345432518518605691907108011661425177022892501.281812215617822326726731235646855760173591311804002.052576971111391671671952222923483754595707377003.554044566480969611212816920121726532942510004.83603241475971718394124148159195242313Voltage: 380/415 V AC20005.45352937425263637384110131141173214277—Lighting circuit switchingContactor selection AF190 ... AF2650 3-pole contactors1SBC101961S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39503
Selection table3-pole AC / DC operated contactorsAF09AF12AF16AF26AF30AF38AF40AF52AF65AF80AF96AF116AF140AF146Lamp characteristicsMaximum permissible number of lamps per phaseWAμFMetal halide vapour lamps without compensationVoltage: 220/240 V AC2503-45577711141618202733384004-33455581112131520252810009.5-1112223455681112200016.5-00111122333567Voltage: 380/415 V AC200010.5-1112223445581011Metal halide vapour lamps with compensationVoltage: 220/240 V AC2501.323377715161725333741456986974002.22455559910141922242741515810005.14852234446891011182225200011.51481111122344581011Voltage: 380/415 V AC20006.106022233357899151921—Lighting circuit switchingContactor selection AF09 ... AF146 3-pole contactors1SBC101961S0201 - Rev. B3/396ABB MOTOR PROTECTION AND CONTROL03
Selection table3-pole AC / DC operated contactorsAF190AF205AF265AF305AF370AF400AF460AF580AF750AF1250AF1350AF1650AF2050 AF2650Lamp characteristicsMaximum permissible number of lamps per phaseWAμFMetal halide vapour lamps without compensationVoltage: 220/240 V AC2503-465867831001001171331752082252753424424004-3444506375758810013115616920625633110009.5-141821263232374255667187108139200016.5-811121518182124323841506280Voltage: 380/415 V AC200010.5-13171924292933385060647998126Metal halide vapour lamps with compensationVoltage: 220/240 V AC2501.323311915117321625925930234545354058371388511444002.2245719010312815415418020527032134742452668010005.14853039445567677889116139150183227294200011.5148141720253030354052626782102131Voltage: 380/415 V AC20006.1060263337475656657598117126154192248—Lighting circuit switchingContactor selection AF190 ... AF2650 3-pole contactors1SBC101961S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39703
Selection table4-pole AC / DC operated contactorsAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370Lamp characteristicsMaximum permissible number of lamps per phaseWAμFIncandescent and halogen lampsVoltage: 220/240 V ACaccording to AC-5b600.27-6477103114177207259430519704759981113013701000.45-384662681061241552583114224565896788222000.91-192330345261771271542092252913354073001.37-12152022354151851021391501932232705002.28-7912132124305161839011613416210004.55-346610121525314245586781Fluorescent lamps without compensation - Fluorescent lamps with electronic starterVoltage: 220/240 V ACaccording to AC-5a200.38-46557381126147184305368500539697803974400.45-38466268106124155258311422456589678822650.70-253040446880100166200271293379436529800.80-212635386070871451752382563313814631001.15-151824264148601011221651782302653221101.20-1417232540465897117158171221254308Fluorescent lamps with parallel compensationVoltage: 220/240 V ACaccording to AC-5a200.185535311011026630930964477810561139147216942056400.2655353107110184215269446538731788101911731423650.42737376673114133166276333452488631726881800.52733375359921071342232693653945105877121000.6516161634347386961782152923154084695691100.701814143030688086166200271293379436529Fluorescent lamps in dual mountingVoltage: 220/240 V ACaccording to AC-5a2 x 202 x 0.14-6275100110171200250414500679732946108913212 x 402 x 0.25-35425662961121402322803804105306107402 x 652 x 0.40-212635386070871451752382563313814632 x 802 x 0.48-182129325058721211461982142763183852 x 1002 x 0.60-14172325404658971171581712212543082 x 1102 x 0.65-1316212336435389108146158204235285Compact fluorescent lampsVoltage: 220/240 V ACaccording to AC-5a50.045-388466622688106612441555257831114222455658896778822270.075-2332803734136407469331547186725332733353340674933110.105-1662002662954575336661105133318101952252429053524150.135-129155207229355414518859103714071519196322592741200.160-10913117519330035043772587511881281165619062313230.180-9711615517226631138864477810561139147216942056Low pressure sodium vapour lamps without compensationVoltage: 220/240 V AC351.4-91215162331397085115124161185225551.4-91215162331397085115124161185225902.1-681010152026475777831071231501353.1-45671014173238525673841011803.1-4567101417323852567384101Low pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC350.62012122727557377164198269290375432524550.62012122727557377164198269290375432524900.925101022223648611101321791942502883491350.9455512123434341101321791942502883491800.945551212343434110132179194250288349—Lighting circuit switchingContactor selection AF09 ... AF370 4-pole contactors1SBC101961S0201 - Rev. B3/398ABB MOTOR PROTECTION AND CONTROL03
Selection table4-pole AC / DC operated contactorsAF09AF16AF26AF38AF40AF52AF80AF116AF140AF190AF205AF265AF305AF370Lamp characteristicsMaximum permissible number of lamps per phaseWAμFHigh pressure sodium vapour lamps without compensationVoltage: 220/240 V AC1501.8-791112182430455474801031191442503,0-4577111418273344486271864004.4-334571012182230334249596006.2-223357813162123303442100010.3-11223458101314182125High pressure sodium vapour lamps with parallel compensationVoltage: 220/240 V AC1501,02012122123334355931121521642122442962501.53677141522293662751011091411631974002.54855891317223745616685981186003.36533661013162834465064749010006.2100223357815182526343948High pressure mercury vapour lamps without compensationVoltage: 220/240 V AC500.60-22283538557391152190261333380475570800.80-162126284155681141431962492853564281251.15-1114182028384779991361731982482972502.15-67910152025425373931061331594003.25-45671013162835486170881057005.40-233468101721293742536310007.50-122345712152127303846Voltage: 380/415 V AC20008-122245611142025293643High pressure mercury vapour lamps with compensationVoltage: 220/240 V AC500.2873636757911715719632640756071381410181221800.43831314853761021272122653654645306637951250.6610202531345066831381732383023454325182501.28181013161725344271891221561782232674002.0525681011162126445676971111391677003.55403456912152632445664809610004.83602344691119243241475971Voltage: 380/415 V AC20005,45352334681017212937425263Metal halide vapour lamps without compensationVoltage: 220/240 V AC2503-45771114182733465867831004004-3455811132025344450637510009.5-11223458111418212632200016.5-011122356811121518Voltage: 380/415 V AC200010.5-11223458101317192429Metal halide vapour lamps with compensationVoltage: 220/240 V AC2501.323377151625334169861191511732162594002.2245559101419244151719010312815410005.14852344681018223039445567200011.514811122348101417202530Voltage: 380/415 V AC20006.1060223357915192633374756—Lighting circuit switchingContactor selection AF09 ... AF370 4-pole contactors1SBC101961S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 3/39903
1SBC101972S02013/400ABB MOTOR PROTECTION AND CONTROL—Parallel connection of main polesGeneralPurpose: Increasing the AC resistive load by wiring connection of main poles in parallel.Remarks:•Parallel connection of main poles to increase the DC resistive load is not acceptable•Parallel connection of main poles does not increase the breaking capacity.The table below shows the uprating factor for Ie / AC-1 max. in relation to the number of poles wired connected in parallel and for a maximum switching frequency.Note: The poles can be connected in parallel via following connecting strips. See details and permissible current in "Accessory" part.•LP, LH, LY and LF for parallel connection of 2 or 3 poles•LG for parallel connection of 4 poles. L2L1L3NA825DL2L1L3NA826DL2L1L3NA827D2 poles in parallel3 poles in parallel4 poles in parallelContactors Factor to be applied to the rated operational current Ie / AC-1 to obtain the permissible current Ie / AC-1 with "n" poles in parallelAC operatedDC operatedCycles / h3-pole contactorsAF09 ... AF96AF09 ... AF966001.62.2–AF116 ... AF1250AF116 ... AF12503001.62.2–AF1350 ... AF2650AF1350 ... AF2650301.62.2–4-pole contactorsAF09 ... AF38A45 ... A75AF09 ... AF386001.62.22.6AF45 ... AF75AE45 ... AE75 TAE45 ... TAE75AF45 ... AF753001.62.22.6EKEK3001.62.22.803
1SBC101971S0201 ABB MOTOR PROTECTION AND CONTROL 3/401—Temporary or intermittent dutyUtilization of contactors for temporary / intermittent dutyThe table below shows the factor (known as "On-load factor") to be applied to the rated operational current Ie / AC-1 to obtain the permissible operational current Ie / AC-1 in relation to the switching frequency and the current flow time per cycle.Operating cycles per hour123612203060120Prefered classes acc. to IEC 60947-4-1 1–3–12–30–120Current flow time per cycleFactors applicable to Ie / AC-15 s 5.254.94.74.34.03.73.42.810 s3.83.73.63.43.13.02.82.62.220 s2.82.72.72.62.52.42.22.01.530 s2.42.32.32.22.12.11.91.7–40 s2.22.12.12.01.91.91.71.5–60 s1.91.81.81.81.71.71.5––Example:AF09 contactor (intermittent duty, resistive load)Rated operational current Ie / AC-1 at 60 °C(see "Technical data: main pole utilization characteristics") 25 ASwitching frequency 2 operating cycles/hCurrent flow time per cycle 20 sFactor to be applied to the current Ie / AC-1 2.7Permissible current: 2.7 x 25 = 67 A03
1SBC100063S02013/4 0 2ABB MOTOR PROTECTION AND CONTROL—Influence of the length of conductors used in contactor control circuitUnder certain conditions the excessive length of the control circuit conductors may prevent the contactor from carrying out closing and opening orders.•no closing: due to excessive voltage drop (in AC or DC)•no opening: due to excessive capacitance (in AC).Contactor Closing (contactor with AC or DC operated coil).The voltage drop is due to the pull-in current (pull-in power) and to the resistance of the control circuit conductors.The table and graph below can be used to determine the single length of line feeders (distance be-tween the control device and the contactor coil) in relation to:•the coil pull-in consumption.•the supply voltage.•the connecting wire cross-sectional area.The graph has been drawn for a max. line voltage drop of 5 %.Coil pull-in consumption (average value)11010010001000012000202353050200300500300050002.5101001000100002.5250002000020002035305020030050030005000410100100010000200004000042000205305020030050030005000300001101001000100001.5101001000100001.515000202353050200300500500023520307020030050020005000Cross-sectional area (Cu) in mm2Coil pull-in consumption: in VA for AC operated contactors in W for DC operated contactorssingle line length in m135791357913579135792900660 V - 690 V500 V380 V - 400 V220 V - 230 V110 V60 V48 V24 V501SBC101014V0014AF40-30-001SFC101133V0001AF370-30-113-pole contactorsAC control supplyDC control supply50/60 HzAF09, AF12, AF16, AF26, AF30, AF3850 VA50 WAF09Z, AF12Z, AF16Z, AF26Z, AF30Z, AF38Z 20 VA20 WAF40, AF52, AF6525 VA25 WAF80, AF9640 VA40 WAF116, AF140, AF146180 VA170 WAF190, AF205195 VA185 WAF265, AF305, AF370405 VA465 WAF400, AF4601005 VA 960 WAF580, AF750, AF1250940 VA900 WAF1350, AF1650, AF2050, AF2650 2450 VA 2290 W4-pole contactorsAC control supplyDC control supply50/60 HzAF09, AF16, AF26, AF3850 VA50 WAF09Z, AF16Z, AF26Z, AF38Z20 W20 WAF40, AF52, AF8040 VA40 WAF116, AF140 185 VA170 WAF190, AF205 190 VA180 WAF265, AF305, AF370405 VA445 WPermissible single length for the control circuit conductors on contactor closing:Depending on the coil pull-in power consumption on the supply voltage and on the control circuit conductor cross-sectional area.Example AF09 contactor: Coil voltage: 230 V 50 Hz, contactor coil pull-in power consumption: 50 VA, control circuit conductor cross-sectional area: Cu 1.5 mm². Max. permissible length: 2900 m.03
1SBC100063S0201 ABB MOTOR PROTECTION AND CONTROL 3/403—Influence of the length of conductors used in contactor control circuitContactor Opening (contactor with AC operated coil)Under certain conditions, an AC operated contactor does not open when the control circuit is de-energized.This is due to a critical capacity of the excessively long control circuit line and the type of contactor coil control layout (see diagrams A and B opposite). This may be caused by the following factors:• high control voltage• low coil holding consumption• low contactor drop-out voltage (according to IEC 60947-4-1: 0.2 to 0.75 x Uc).If lines longer than those indicated are required, the following measures must be taken:• select a contactor with a higher rating• select a lower control voltage• connect "Rp" resistance in parallel with the contactor coil: 103 RP = (with C in μF) CThe table and graph below can be used to determine the single length of line feeders (distance be-tween the control device and the contactor coil) in relation to:• the coil holding consumption VA• the supply voltage• the capacity in μF/km (depending on the control layout).Wiring diagrams A and B opposite show two supply and coil control wiring examples.Coil holding consumption (average value)0.60Coil holding consumption in VASingle line length in m10100100021.7352030502003005001700110100100023572030502003005000.10101001000100002030502003005002000300050000.20101001000305020030050020003000500050.301010010003.35203050200300500200033000.401010010002.55203050200300500200025000.501010010002352030502003005002000Line capacitance in μF/km380 V - 400 V660 V - 690 V220 V - 230 V110 V60 V48 V24 V500 V2.2171357913579135793-pole contactorsAC control supply50/60 HzAF09, AF12, AF16, AF26, AF30, AF382.2 VAAF09Z, AF12Z, AF16Z, AF26Z, AF30Z, AF38Z1.7 VAAF40, AF52, AF65, AF80, AF964 VAAF116, AF140, AF1468.9 VAAF190, AF2059.3 VAAF265, AF305, AF37016.6 VAAF400, AF460, AF580, AF750, AF125012 VAAF1350, AF1650, AF2050, AF2650 48 VA4-pole contactorsAC control supply50/60 HzAF09, AF16, AF26, AF382.2 VAAF09Z, AF16Z, AF26Z, AF38Z1.7 VAAF40, AF52, AF804 VAAF116, AF140, AF190, AF2058 VAAF265, AF305, AF37016 VAPermissible single length for the control circuit conductors on contactor opening:Depending on the coil holding power consumption, on the supply voltage and on the control circuit conductor capacity.Example AF16 contactor: Coil voltage Uc = 500 V, 50 Hz, 2.2 VA contactor coil holding consumption, control type: diagram A, via maintained pushbutton, and 2-core cable with a capacity of 0.2 μF/km. Max. permissible length: 17 m.Single control line lengthA841DWiring diagram AVia maintained pushbutton and 2-core cable (with a capacity of 0.2 μF/km, for example).A840DWiring diagram BVia momentary pushbutton plus hold-in contact and 3-core cable (with a capac-ity of 2 x 0.2 = 0.4 μF/km, for example).1SBC100063S020103
—Voltage code tableThe below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give the order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the order code according to the table below. Example: for contactor AF400-30-11 and coil 100...250 V 50/60 Hz, the order code is: 1SFL577001R7011.AF09 ... AF370 3-pole contactorsAF09 ... AF370 4-pole contactorsAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeAF09Z- 30- 10-21AC coil codeDC coil code 50/60 Hz20 - 12...20 V21 24...60 V 20...60 V22 48...130 V 48...130 V23 100...250 V 100...250 V1SBL136001R2110AF09 ... AF38 3- and 4-pole contactors - low consumptionLow coil consumptionContactor typeAC / DC operatedAF..AF400 ... AF2650 3-pole contactorsCoil 68, 69, 71: not available for AF1350 ... AF2650Auxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeAC / DC operatedAF400- 30- 11AF..AC coil codeDC coil code 50/60 Hz68 - 24...60 V69 48...130 V 48...130 V70 100...250 V 100...250 V71 250...500 V 250...500 V1SFL577001R6911Auxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeAC / DC operatedAF09- 30- 10-13AF..AC coil codeAC coil codeDC coil codeDC coil code 50/60 Hz41 24...60 V -11 24...60 V 20...60 V12 48...130 V 48...130 V13 100...250 V 100...250 V14 250...500 V 250...500 V 50/60 Hz33 100...250 V 100...250 V34 250...500 V 250...500 V1SBL137001R1310AF116 ... AF370 3-pole contactorswith built-in PLC interfaceCoil 41: not available for AF116 ... AF3703/4 0 4 ABB MOTOR PROTECTION AND CONTROL1SBC101601S0201 - Rev. E03
—Voltage code tableNF contactor relaysN.O. N.C. Number contacts Ty peOrder codeNF 22E -13AC coil codeDC coil code 50/60 Hz41 24...60 V -11 24...60 V 20...60 V12 48...130 V 48...130 V13 100...250 V 100...250 V14 250...500 V 250...500 V1SBH137001R1322Contactor typeAC / DC operatedNFN.O. N.C. Number contacts N.O. leading contactsN.C. lagging contactsTy peOrder codeNF 33/11-13AC coil codeDC coil code 50/60 Hz41 24...60 V -11 24...60 V 20...60 V12 48...130 V 48...130 V13 100...250 V 100...250 V14 250...500 V 250...500 V1SBH137001R1339NF contactor relays with overlapping of lagging / leading contactsContactor typeAC / DC operatedNFLow coil consumptionContactor typeAC / DC operatedN.O. N.C. Number contacts Ty peOrder codeNFZ22E -21NFAC coil codeDC coil code 50/60 Hz20 - 12...20 V21 24...60 V 20...60 V22 48...130 V 48...130 V23 100...250 V 100...250 V1SBH136001R2122NF contactor relays - low consumptionN.O. leading contactsN.C. lagging contactsLow coil consumptionContactor typeAC / DC operatedN.O. N.C. Number contacts Ty peOrder codeNFZ33/11E -21NFAC coil codeDC coil code 50/60 Hz20 - 12...20 V21 24...60 V 20...60 V22 48...130 V 48...130 V23 100...250 V 100...250 V1SBH136001R2139NF contactor relays with overlapping of lagging / leading contacts - low consumption ABB MOTOR PROTECTION AND CONTROL 3/4051SBC101601S0201 - Rev. E03
—Voltage code tableContactors: GA AC coil codeContactors: GAE DC coil codeAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeGA75 -10- 00GA DC switching - AC operatedGAE DC switching - DC operated1SBL411025R820050 Hz 60 Hz81 24 V 24 V82 42 V 42 V83 48 V 48 V84 110 V 110...120 V89110...115 V 115...127 V80220...230 V 230...240 V88230...240 V 240...260 V42 230...240 V 277 V85380...400 V 400...415 V86400...415 V 415...440 VCodes in bold for dual frequency coils.80 12 V81 24 V82 42 V83 48 V86 110 V87 125 V88 220 V89 240 V38 250 VGA contactorsAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeAC / DC operatedGAF185 -10- 11GAFAC coil codeDC coil code50/60 Hz72 - 20...60 V69 48...130 V 48...130 V70 100...250 V 100...250 V1SFL497025R6911GAF185 ... GAF300 contactorsGAF460 ... GAF1250 contactorsAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeAC / DC operatedGAF460 -10- 11GAFAC coil codeDC coil code50/60 Hz68 - 24...60 V69 48...130 V 48...130 V70 100...250 V 100...250 V71 250...500 V 250...500 V1SFL597025R69113/406ABB MOTOR PROTECTION AND CONTROL1SBC101601S0201 - Rev. E03
—Voltage code tableContactors: UA..RA AC coil codeAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeUA16- 30 -10RAUA..RA Capacitor switching - AC operated1SBL181024R8410 50 Hz 60 Hz81 24 V 24 V84 110 V 110...120 V89 110...115 V 115...127 V36 190 V 220 V80 220...230 V 230...240 V88 230...240 V 240...260 V85 380...400 V 400...415 V86 400...415 V 415...440 V75 200 V 200...220 VCodes in bold for dual frequency coils.UA..RA contactorsGAF1650, GAF2050 contactorsAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeGAF1650 -10- 11AC coil codeDC coil code 50/60 Hz70 100...250 V 100...250 V1SFL677025R7011Contactor typeAC / DC operatedGAFContactors: UA AC coil codeAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeUA16- 30 -10UA Capacitor switching - AC operated1SBL181022R8310 50 Hz 60 Hz81 24 V 24 V83 48 V 48 V84 110 V 110...120 V89 110...115 V 115...127 V36 190 V 220 V80 220...230 V 230...240 V88 230...240 V 240...260 V42 230...240 V 277 V85 380...400 V 400...415 V86 400...415 V 415...440 V75 200 V 200...220 VCodes in bold for dual frequency coils.UA contactors ABB MOTOR PROTECTION AND CONTROL 3/4071SBC101601S0201 - Rev. E03
—Voltage code tableAuxiliary contacts N.O. N.C.N.O. N.C. Main contactsTy peOrder codeContactor typeEK550 - 40 - 11EK AC operated or DC operatedSK827041-ADEK550, EK1000 contactorsDual frequency coil code50 Hz 60 HzEF 110 V 110...120 VEG 110...115 V 115...127 VEL 220 V 220...240 VEM 220...230 V 230...255 VEP 380 V 380...415 VER 380...400 V 400...440 V2 auxiliary contact blocks maximum per contactor, ambient temperature ≤ 55 °C and mounting positions 2 and 6 excluded.DC coil codeDB 24 VDC 36 VDD 48 VDT 60 VDG 75 VDE 110 VDU 125 VDF 220 VAC coil code50 Hz 60 HzAD 48 V -AE - 110 VAF 110 V 120 VAG 127 V -AZ - 208 VAH 190 V 220 VAK - 240 VAL 220...230 V 240 VAM 230...240 V -AN - 380 VAP 380...400 V 440 VAR 400...415 V -AS - 480 VAT 440 V -AU 500 V -AV - 600 V3/4 0 8ABB MOTOR PROTECTION AND CONTROL1SBC101601S0201 - Rev. E03
—Questionnaire for product specifications:Block contactorsTel.: e-mail: Segments: Tel.: e-mail: Date: ApplicationType: No of phases: Utilisation category (AC/DC): % AC4 if any: Rated operational voltage Ue: V Cos j: Frequency: Hz L/R: msNominal current In: A Making current: A Breaking current: ADuty: continuous temporary intermittentLoad factor (% of ON time): %Number of cycles per hour: or per year: Expected durability: operating cyclesNumber of main poles N.O.: N.C.: Other information: InstallationAmbient temperature: Ambient environment: Humidity: %Chemical pollution: Other: Mounting position, see drawing below (Position 6: please consult factory): Pos. 5Pos. 6Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Wiring: Clamping screws or cage connectors Cable lugs (ring tongue) Other: Cross section: Additional comments: Control circuit Rated control Uc voltage: V DC AC f: HzMinimum / maximum: V to VSurge suppressor: type: Interface with PLC: mA V DCAccessories: Number of auxiliary contacts: N.O.: N.C.: Low level contacts: mA V DC ACProtection Short circuit protection: Typ e : Fuse Circuit breaker Manual motor starterMax short circuit current: AMotor protection: Overload relay Manual Motor Starter Electronic overload relayLogistic and packaging Quantity by batch: Delivery order: Expected quantity: per year Expected first delivery date: and Qty: Quantity on first 6 month: on first year: Approvals and other requirementsReference standards: Required approvals: Customer specifications: Shock and vibrations: Specific quality assurance clauses: Other comments: ABB MOTOR PROTECTION AND CONTROL 3/4091SBC101701S020103
—Questionnaire for product specifications:Block contactorsOther comments: ................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................User Guide for the questionnaireThis document is used to define the contactor specifications according to the complete information on the application.Do not hesitate to join some complementary documents if necessary (schemes, tables, customer specification...).Please see below some definitions to help you :Operating cycleIncludes one making operation and one breaking operation.Electrical DurabilityNumber of on-load operating cycles that the contactor is able to carry out. It depends on the utilization category.Mechanical DurabilityNumber of no-current operating cycles that the contactor is able to carry outLoad FactorRatio of the on-load operating time to the total cycle time x 100 (%).Intermittent DutyDuty during which the contactor is successively closed or open for periods which are too short to enable the contactor to achieve thermal balance.Temporary DutyDuty in which the main contacts of the contactor remain closed for periods insufficient to allow the equipment to reach stabilized temperature, the unload periods being separated by off-load periods of sufficient duration to restore the ambient temperatureContinuous DutyDuty in which the main contacts of the contactor remain closed, with a continuous current during enough time to reach thermal sta-bilization, but no more than eight hours without interruption.Ambient TemperatureAir temperature close to the contactor.Mounting PositionComply with the manufacturer's instructions. Restrictions could be taken into account for certain mounting positions.A contactor's duty is characterized by the utilization category together with the rated operational voltage and current indicated:Utilization categories for contactors according to IEC 60947-4-1Utilization categories for contactor relays according to IEC 60947-5-1See our catalog p7/8Making and breaking currentCurrent at contactor closing or at contactor openingTime constant L/R (for DC circuit)Ratio of the inductance to the resistance (L/R = mH/Ω = ms)3/410ABB MOTOR PROTECTION AND CONTROL1SBC101701S020103
—Notes ABB MOTOR PROTECTION AND CONTROL 3/41103
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/BC6-30-10-07 www.abb.com/productdetails/GJL1213001R0107or
ABB B MINI CONTACTORS, K MINI CONTACTOR RELAYS 4/1—B mini contactorsK mini contactor relays044/3 Presentation 4/6 OverviewWith screw terminals4/8 3-pole contactors AC and DC operated4/10 3-pole reversing contactors AC and DC operated4/14 3-pole interface contactors DC operated4/15 4-pole contactors AC and DC operated4/17 Contactor relays AC and DC operated4/19 Interface contactor relays DC operatedWith soldering pins 4/20 3-pole contactors AC and DC operated4/22 3-pole reversing contactors AC and DC operated4/26 3-pole interface contactors DC operated4/27 Contactor relays AC and DC operated4/29 Interface contactor relays DC operatedWith flat pin connection 4/30 3-pole contactors AC and DC operated4/32 3-pole reversing contactors AC and DC operated4/36 3-pole interface contactors DC operated4/37 Contactor relays AC and DC operated4/39 Interface contactor relays DC operated4/40 Technical data4/47 Accessories4/52 Location of the connection terminals and terminal designation4/53 Dimension drawings
4/2ABB MOTOR PROTECTION AND CONTROL04
—B mini contactorsFlexibility in small spacesMini contactors are ideally suited for applications where reliability is a must and space is at a premium. The dimensions, technical features and the variety of the assortment provide customers a high flexibility in a wide-range of applications.Space-savingDesigned to be miniThis type of contactor is a specialist for applica-tions in small spaces. It comes with three differ-ent terminal types. Side or front auxiliary contact blocks can be mounted to match the require-ments of width or depth limitations.Optimum interfaceGreat flexibilityB mini offer many possibilities to adapt to any project. It offers screw terminals, soldering pins or flat pin connectors and different coil versions. This makes this contactor a perfect fit and simpli-fies the installation greatly.Speed up your projectsSimpler by designYou can easily combine a manual motor starter or overload relay with a mini contactor in order to create the solution of your choice. Reversing starters come pre-assembled from the factory, which saves time. With the right accessories, this range is simple to use.ABB MOTOR PROTECTION AND CONTROL 4/304
2CDC102073C0201—B mini contactorSmart - flexibility and diversity in a small sizeMountable in just about any placeAccording to the available space, auxil-iary contacts can be mounted on the front or at the side of the B mini. Also, additional surge protection can be fit-ted on any side of the contactor.Save assembly timeThis range offers reversing starters delivered as one piece from the factory. It avoids mounting mistakes and secures operation. It is also available with mechanical interlock for special demands.ACDCorSoldering pins Soldering pin terminalsThis connection type allows an easy installation on PCB boards, where all components have to be soldered in place. The soldering pins sustain currents up to AC-1/AC-3 12 A.Screw Screw terminalsThis conventional terminal type enables a quick connection to an installation using just a one size screwdriver. All terminal screws, from power to control, are aligned and accessible from the front for easy tightening.Flat pins Flat pin terminalsThanks to really quick plug-in assembling, good reliability of the connection and low costs, the flat pin terminals are already the favorite choice in many industry sectors. The best option when high con-nection speed is required.Perfect fit Mini contactors match manual motor starters or overload relays. This creates a space-saving and easy to install motor starting solution for a complete protection and control of your devices.4/4ABB MOTOR PROTECTION AND CONTROL04
2CDC102073C0201—B mini contactorCompact - a tiny specialist for specific needsChoose your specialist. No matter what kind of application - The B range includes contactors with low power consumption coils and integrated surge suppression for direct control by PLC. Dedicated relay versions for control functions or for small oads are also available.Extreme conditions Manufactured with resistant and high performances materials, the B Mini Contactors can be precious allies even for applications in extreme conditions. Specific versions with wide operating temperature ranges and coil voltage ranges are part of our offer.Resisitive loads Not only motors! The ABB Mini Contactors can be used for the activation of your AC-1 / DC-1 loads up to 20 A as well. Heaters, coffee machines and o vens are just examples of products in which it is possible to utilize this reliable and silent device as a component.Motors control With a maximum rated operational power AC-3 of 5.5 kW at 400 V the B Mini Contactors are the best solution for controlling the small motors inside your products. If the both direction control is needed, the reversing contactors are always ready to help. ABB MOTOR PROTECTION AND CONTROL 4/504
4/6ABB MOTOR PROTECTION AND CONTROLScrew terminalsSoldering pinsFlat pinsAC Control supply3-pole contactorsCoil consumption 3.5 WTy peB6B7--B6...PB7...P--B6...FB7...F--3-pole reversing contactorsCoil consumption 3.5 WTy pe--VB6VB6A (2)VB7VB7A (2)--VB6...PVB6A...P (2)VB7...PVB7A...P (2)--VB6...FVB6A...F (2)VB7...FVB7A...F (2)4-pole contactorsCoil consumption 3.5 WTy peB6B7(3)(3)(3)(3)(3)(3)(3)(3)DC Control supply3-pole contactorsCoil consumption 3.5 WTy peBC6BC7B7D (1)--BC6...PBC7...PB7D...P (1)--BC6...FBC7...FB7D...F (1)--3-pole reversing contactorsCoil consumption 3.5 WTy pe--VBC6VBC6A (2)VBC7VBC7A (2)--VBC6...PVBC6A...P (2)VBC7...PVBC7A...P (2)--VBC6...FVBC6A...F (2)VBC7...FVBC7A...F (2)3-pole interface contactorsCoil consumption 1.4 ... 2.8 WTy peBC6B6S (1)BC7B7S (1)(3)(3)BC6...PBC7...P(3)(3)BC6...FBC7...F--4-pole contactorsCoil consumption 3.5 WTy peBC6B7D(3)(3)(3)(3)(3)(3)(3)(3)IECRated operational power AC-3220-230-240 VkW2.232.232.232.232.232.23380-400 VkW45.545.545.545.545.545.5Rated operational current AC-1400 V, θ ≤ 40 °CA202020201212121220202020UL/CSA3-phase motor rating220-240 V AChp232323232323440-480 V AChp353535353535General use ratingA12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)Main accessoriesAuxiliary contact blocksFront mountingCAF6--Side mountingCA6-CA6-11K-P-CA6-11K-F-Connection setsFor reversing contactorsBSM6-30--Surge suppressorsVaristor (AC/DC)RV-BC6--Overload relaysThermal overload relays Thermal and phase failure protection, with single setup possibleClass 10T16--Electronic overload relays With single setup possibleClass 10E, 20E, 30EE16DU--Manual motor startersThermal / magnetic protectionClass 10MS116, MS132MS116, MS132MS116, MS132Magnetic only typesMO132MO132MO132Connecting link to manual motor startersBEA7/132--—Mini contactorsScrew terminalsSoldering pinsFlat pinsAC Control supply4-pole contactor relaysCoil consumption 3.5 WTy peK6K6...PK6...FDC Control supply4-pole contactor relaysCoil consumption 3.5 WTy peKC6KC6...PKC6...F4-pole interface contactor relaysCoil consumption 1.4 ... 2.8 WTy peKC6, K6S (1)KC6...PKC6...FIECRated operational current AC-15220-230-240 VA444380-400 VA333Rated operational current DC-1324 VA2.52.52.5Main accessoriesAuxiliary contact blocksFront mountingCAF6--Side mountingCA6-11KCA6-11K-PCA6-11K-F(1) With integrated surge suppressor(2) With safety blocking function(3) Please visit: https://new.abb.com/low-voltage/products/motor-protection/3-pole-contactors-and-overload-relays-for-motor-starting/mini-contactors—Mini contactor relays04
2CDC102050C0201 ABB MOTOR PROTECTION AND CONTROL 4/7Screw terminalsSoldering pinsFlat pinsAC Control supply3-pole contactorsCoil consumption 3.5 WTy peB6B7--B6...PB7...P--B6...FB7...F--3-pole reversing contactorsCoil consumption 3.5 WTy pe--VB6VB6A (2)VB7VB7A (2)--VB6...P VB6A...P (2)VB7...P VB7A...P (2)--VB6...F VB6A...F (2)VB7...F VB7A...F (2)4-pole contactorsCoil consumption 3.5 WTy peB6B7(3)(3)(3)(3)(3)(3)(3)(3)DC Control supply3-pole contactorsCoil consumption 3.5 WTy peBC6BC7B7D (1)--BC6...PBC7...PB7D...P (1)--BC6...FBC7...FB7D...F (1)--3-pole reversing contactorsCoil consumption 3.5 WTy pe--VBC6VBC6A (2)VBC7VBC7A (2)--VBC6...PVBC6A...P (2)VBC7...PVBC7A...P (2)--VBC6...FVBC6A...F (2)VBC7...FVBC7A...F (2)3-pole interface contactorsCoil consumption 1.4 ... 2.8 WTy peBC6B6S (1)BC7B7S (1)(3)(3)BC6...PBC7...P(3)(3)BC6...FBC7...F--4-pole contactorsCoil consumption 3.5 WTy peBC6B7D(3)(3)(3)(3)(3)(3)(3)(3)IECRated operational power AC-3220-230-240 VkW2.232.232.232.232.232.23380-400 VkW45.545.545.545.545.545.5Rated operational current AC-1400 V, θ ≤ 40 °CA202020201212121220202020UL/CSA3-phase motor rating220-240 V AChp232323232323440-480 V AChp353535353535General use ratingA12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)12 (300 V)16 (600 V)Main accessoriesAuxiliary contact blocksFront mountingCAF6--Side mountingCA6-CA6-11K-P-CA6-11K-F-Connection setsFor reversing contactorsBSM6-30--Surge suppressorsVaristor (AC/DC)RV-BC6--Overload relaysThermal overload relays Thermal and phase failure protection, with single setup possibleClass 10T16--Electronic overload relays With single setup possibleClass 10E, 20E, 30EE16DU--Manual motor startersThermal / magnetic protectionClass 10MS116, MS132MS116, MS132MS116, MS132Magnetic only typesMO132MO132MO132Connecting link to manual motor startersBEA7/132--Screw terminalsSoldering pinsFlat pinsAC Control supply4-pole contactor relaysCoil consumption 3.5 WTy peK6K6...PK6...FDC Control supply4-pole contactor relaysCoil consumption 3.5 WTy peKC6KC6...PKC6...F4-pole interface contactor relaysCoil consumption 1.4 ... 2.8 WTy peKC6, K6S (1)KC6...PKC6...FIECRated operational current AC-15220-230-240 VA444380-400 VA333Rated operational current DC-1324 VA2.52.52.5Main accessoriesAuxiliary contact blocksFront mountingCAF6--Side mountingCA6-11KCA6-11K-PCA6-11K-F(1) With integrated surge suppressor(2) With safety blocking function(3) Please visit: https://new.abb.com/low-voltage/products/motor-protection/3-pole-contactors-and-overload-relays-for-motor-starting/mini-contactors04
2CDC102008C02014/8ABB MOTOR PROTECTION AND CONTROLB6, B7 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:•3 main poles and one built-in auxiliary contact•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for front or side mounting and a wide range of accessories•designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgB6 mini contactors4203300 V / 12 A24241 0B6-30-10-01GJL1211001R0101100.1750 1B6-30-01-01GJL1211001R0011100.17542421 0B6-30-10-02GJL1211001R0102100.1750 1B6-30-01-02GJL1211001R0012100.17548481 0B6-30-10-03GJL1211001R0103100.1750 1B6-30-01-03GJL1211001R0013100.175110 ... 127 110 ... 1271 0B6-30-10-84GJL1211001R8104100.1750 1B6-30-01-84GJL1211001R8014100.175220 ... 240 220 ... 2401 0B6-30-10-80GJL1211001R8100100.1750 1B6-30-01-80GJL1211001R8010100.175380 ... 415 380 ... 4151 0B6-30-10-85GJL1211001R8105100.1750 1B6-30-01-85GJL1211001R8015100.175B7 mini contactors5.5205600 V / 16 A 24241 0B7-30-10-01GJL1311001R0101100.1750 1B7-30-01-01GJL1311001R0011100.17542421 0B7-30-10-02GJL1311001R0102100.1750 1B7-30-01-02GJL1311001R0012100.17548481 0B7-30-10-03GJL1311001R0103100.1750 1B7-30-01-03GJL1311001R0013100.175110 ... 127 110 ... 1271 0B7-30-10-84GJL1311001R8104100.1750 1B7-30-01-84GJL1311001R8014100.175220 ... 240 220 ... 2401 0B7-30-10-80GJL1311001R8100100.1750 1B7-30-01-80GJL1311001R8010100.175380 ... 415 380 ... 4151 0B7-30-10-85GJL1311001R8105100.1750 1B7-30-01-85GJL1311001R8015100.175Other types on request 2CDC211001F0010B6-30-10 2CDC211014F0011B7-30-10—B6, B7 3-pole mini contactors – with screw terminals4 to 5.5 kWAC operatedMain dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"B6, B704
2CDC102015C0201 ABB MOTOR PROTECTION AND CONTROL 4/9—BC6, BC7, B7D 3-pole mini contactors – with screw terminals4 to 5.5 kWDC operatedBC6, BC7, B7D 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:• 3 main poles and one built-in auxiliary contact• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories• designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgBC6 mini contactors4203300 V / 12 A121 0BC6-30-10-07GJL1213001R0107100.1750 1BC6-30-01-07GJL1213001R0017100.175241 0BC6-30-10-01GJL1213001R0101100.1750 1BC6-30-01-01GJL1213001R0011100.175481 0BC6-30-10-16GJL1213001R1106100.1750 1BC6-30-01-16GJL1213001R1016100.175601 0BC6-30-10-03GJL1213001R0103100.1750 1BC6-30-01-03GJL1213001R0013100.175110 ... 1251 0BC6-30-10-04GJL1213001R0104100.1750 1BC6-30-01-04GJL1213001R0014100.175220 ... 2401 0BC6-30-10-05GJL1213001R0105100.1750 1BC6-30-01-05GJL1213001R0015100.175BC7 mini contactors5.5205600 V / 16 A121 0BC7-30-10-07GJL1313001R0107100.1750 1BC7-30-01-07GJL1313001R0017100.175241 0BC7-30-10-01GJL1313001R0101100.1750 1BC7-30-01-01GJL1313001R0011100.175481 0BC7-30-10-16GJL1313001R1106100.1750 1BC7-30-01-16GJL1313001R1016100.175601 0BC7-30-10-03GJL1313001R1103100.1750 1BC7-30-01-03GJL1313001R0013100.175110 ... 1251 0BC7-30-10-04GJL1313001R0104100.1750 1BC7-30-01-04GJL1313001R0014100.175220 ... 2401 0BC7-30-10-05GJL1313001R0105100.1750 1BC7-30-01-05GJL1313001R0015100.175B7D mini contactors with integrated suppressor diode5.5205600 V / 16 A241 0B7D-30-10-01GJL1317001R0101100.1750 1B7D-30-01-01GJL1317001R0011100.1752201 0B7D-30-10-05GJL1317001R0105100.1750 1B7D-30-01-05GJL1317001R0015100.175Other types on request 2CDC211040F0011BC6-30-10 2CDC211013F0011BC7-30-10Main dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"BC6, BC7, B7D04
2CDC102016C02014/10ABB MOTOR PROTECTION AND CONTROL—VB6, VB7 3-pole mini reversing contactors – with screw terminals4 to 5.5 kWAC operatedVB6, VB7 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:•built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc.•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for front mounting•designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgVB6 mini reversing contactors4203300 V / 12 A24241 0VB6-30-10-01GJL1211901R010150.3550 1VB6-30-01-01GJL1211901R001150.35542421 0VB6-30-10-02GJL1211901R010250.3550 1VB6-30-01-02GJL1211901R001250.35548481 0VB6-30-10-03GJL1211901R010350.3550 1VB6-30-01-03GJL1211901R001350.355110 ... 127 110 ... 1271 0VB6-30-10-84GJL1211901R810450.3550 1VB6-30-01-84GJL1211901R801450.355220 ... 240 220 ... 2401 0VB6-30-10-80GJL1211901R810050.3550 1VB6-30-01-80GJL1211901R801050.355380 ... 415 380 ... 4151 0VB6-30-10-85GJL1211901R810550.3550 1VB6-30-01-85GJL1211901R801550.355VB7 mini reversing contactors5.5205600 V / 16 A24241 0VB7-30-10-01GJL1311901R010150.3550 1VB7-30-01-01GJL1311901R001150.35542421 0VB7-30-10-02GJL1311901R010250.3550 1VB7-30-01-02GJL1311901R001250.35548481 0VB7-30-10-03GJL1311901R010350.3550 1VB7-30-01-03GJL1311901R001350.355110 ... 127 110 ... 1271 0VB7-30-10-84GJL1311901R810450.3550 1VB7-30-01-84GJL1311901R801450.355220 ... 240 220 ... 2401 0VB7-30-10-80GJL1311901R810050.3550 1VB7-30-01-80GJL1311901R801050.355380 ... 415 380 ... 4151 0VB7-30-10-85GJL1311901R810550.3550 1VB7-30-01-85GJL1311901R801550.355Other types on request 2CDC211006F0011VB7-30-10Main dimensions mm, inches4.5 0.18"43.7 1.72"46.7 1.84"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VB6, VB704
2CDC102017C0201 ABB MOTOR PROTECTION AND CONTROL 4/11—VBC6, VBC7 3-pole mini reversing contactors – with screw terminals4 to 5.5 kWDC operatedVBC6, VBC7 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc.• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front mounting• designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC6 mini reversing contactors4203300 V / 12 A121 0VBC6-30-10-07GJL1213901R010750.3550 1VBC6-30-01-07GJL1213901R001750.355241 0VBC6-30-10-01GJL1213901R010150.3550 1VBC6-30-01-01GJL1213901R001150.355481 0VBC6-30-10-16GJL1213901R110650.3550 1VBC6-30-01-16GJL1213901R101650.355601 0VBC6-30-10-03GJL1213901R010350.3550 1VBC6-30-01-03GJL1213901R001350.355110 ... 1251 0VBC6-30-10-04GJL1213901R010450.3550 1VBC6-30-01-04GJL1213901R001450.355220 ... 2401 0VBC6-30-10-05GJL1213901R010550.3550 1VBC6-30-01-05GJL1213901R001550.355VBC7 mini reversing contactors5.5205600 V / 16 A121 0VBC7-30-10-07GJL1313901R010750.3550 1VBC7-30-01-07GJL1313901R001750.355241 0VBC7-30-10-01GJL1313901R010150.3550 1VBC7-30-01-01GJL1313901R001150.355481 0VBC7-30-10-16GJL1313901R110650.3550 1VBC7-30-01-16GJL1313901R101650.355601 0VBC7-30-10-03GJL1313901R010350.3550 1VBC7-30-01-03GJL1313901R001350.355110 ... 1251 0VBC7-30-10-04GJL1313901R010450.3550 1VBC7-30-01-04GJL1313901R001450.355220 ... 2401 0VBC7-30-10-05GJL1313901R010550.3550 1VBC7-30-01-05GJL1313901R001550.355Other types on request 2CDC211042F0011VBC6-30-10 2CDC211001F0011VBC7-30-10Main dimensions mm, inches4.5 0.18"43.7 1.72"46.7 1.84"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VBC6, VBC704
2CDC102018C02014/12 ABB MOTOR PROTECTION AND CONTROL—VB6A, VB7A 3-pole mini reversing contactors – with screw terminals4 to 5.5 kWAC operated – with safety blocking function VB6A, VB7A 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.• control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front mounting• designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 HzV AC60 HzV ACkWAhpkgVB6A mini reversing contactors with safety blocking function4203300 V / 12 A24241 0VB6A-30-10-01GJL1211911R010150.3550 1VB6A-30-01-01GJL1211911R001150.35542421 0VB6A-30-10-02GJL1211911R010250.3550 1VB6A-30-01-02GJL1211911R001250.35548481 0VB6A-30-10-03GJL1211911R010350.3550 1VB6A-30-01-03GJL1211911R001350.355110 ... 127 110 ... 1271 0VB6A-30-10-84GJL1211911R810450.3550 1VB6A-30-01-84GJL1211911R801450.355220 ... 240 220 ... 2401 0VB6A-30-10-80GJL1211911R810050.3550 1VB6A-30-01-80GJL1211911R801050.355380 ... 415 380 ... 4151 0VB6A-30-10-85GJL1211911R810550.3550 1VB6A-30-01-85GJL1211911R801550.355VB7A mini reversing contactors with safety blocking function5.5205600 V / 16 A24241 0VB7A-30-10-01GJL1311911R010150.3550 1VB7A-30-01-01GJL1311911R001150.35542421 0VB7A-30-10-02GJL1311911R010250.3550 1VB7A-30-01-02GJL1311911R001250.35548481 0VB7A-30-10-03GJL1311911R010350.3550 1VB7A-30-01-03GJL1311911R001350.355110 ... 127 110 ... 1271 0VB7A-30-10-84GJL1311911R810450.3550 1VB7A-30-01-84GJL1311911R801450.355220 ... 240 220 ... 2401 0VB7A-30-10-80GJL1311911R810050.3550 1VB7A-30-01-80GJL1311911R801050.355380 ... 415 380 ... 4151 0VB7A-30-10-85GJL1311911R810550.3550 1VB7A-30-01-85GJL1311911R801550.355Other types on request 2CDC211037F0011VB6A-30-10 2CDC211008F0011VB7A-30 -10Main dimensions mm, inches4.5 0.18"43.7 1.72"46.7 1.84"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VB6A, VB7A04
2CDC102019C0201 ABB MOTOR PROTECTION AND CONTROL 4/13—VBC6A, VBC7A 3-pole mini reversing contactors – with screw terminals4 to 5.5 kWDC operated – with safety blocking function VBC6A, VBC7A 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front mounting• designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC6A mini reversing contactors with safety blocking function4203300 V / 12 A121 0VBC6A-30-10-07GJL1213911R010750.3550 1VBC6A-30-01-07GJL1213911R001750.355241 0VBC6A-30-10-01GJL1213911R010150.3550 1VBC6A-30-01-01GJL1213911R001150.355481 0VBC6A-30-10-16GJL1213911R110650.3550 1VBC6A-30-01-16GJL1213911R101650.355601 0VBC6A-30-10-03GJL1213911R010350.3550 1VBC6A-30-01-03GJL1213911R001350.355110 ... 1251 0VBC6A-30-10-04GJL1213911R010450.3550 1VBC6A-30-01-04GJL1213911R001450.355220 ... 2401 0VBC6A-30-10-05GJL1213911R010550.3550 1VBC6A-30-01-05GJL1213911R001550.355VBC7A mini reversing contactors with safety blocking function5.5205600 V / 16 A121 0VBC7A-30-10-07GJL1313911R010750.3550 1VBC7A-30-01-07GJL1313911R001750.355241 0VBC7A-30-10-01GJL1313911R010150.3550 1VBC7A-30-01-01GJL1313911R001150.355481 0VBC7A-30-10-16GJL1313911R110650.3550 1VBC7A-30-01-16GJL1313911R001650.355601 0VBC7A-30-10-03GJL1313911R010350.3550 1VBC7A-30-01-03GJL1313911R001350.355110 ... 1251 0VBC7A-30-10-04GJL1313911R010450.3550 1VBC7A-30-01-04GJL1313911R001450.355220 ... 2401 0VBC7A-30-10-05GJL1313911R010550.3550 1VBC7A-30-01-05GJL1313911R001550.355Other types on request 2CDC211044F0011VBC6A-30-10 2CDC211007F0011VBC7A-30 -10Main dimensions mm, inches4.5 0.18"43.7 1.72"46.7 1.84"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VBC6A, VBC7A04
2CDC102010C02014/14 ABB MOTOR PROTECTION AND CONTROL—BC6, BC7 3-pole interface mini contactors – with screw terminals4 to 5.5 kWDC operatedBC6, BC7 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:• 3 main poles and one built-in auxiliary contact• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs• hum-free coil• no auxiliary contact block permitted for mounting• designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgDC operation 24 V / 1.4 W4203300 V / 12 A241 0BC6-30-10-1.4-81GJL1213001R8101100.1750 1BC6-30-01-1.4-81GJL1213001R8011100.1755.5205600 V / 16 A241 0BC7-30-10-1.4-81GJL1313001R8101100.1750 1BC7-30-01-1.4-81GJL1313001R8011100.175DC operation 17 ... 32 V / 2.4 W4203300 V / 12 A17 ... 321 0BC6-30-10-2.4-51GJL1213001R5101100.1750 1BC6-30-01-2.4-51GJL1213001R5011100.1755.5205600 V / 16 A17 ... 321 0BC7-30-10-2.4-51GJL1313001R5101100.1750 1BC7-30-01-2.4-51GJL1313001R5011100.175Connection to PLCs with integrated protective circuitDC operation 24 V / 1.7 W4203300 V / 12 A241 0B6S-30-10-1.7-71GJL1213001R7101100.1750 1B6S-30-01-1.7-71GJL1213001R7011100.1755.5205600 V / 16 A241 0B7S-30-10-1.7-71GJL1313001R7101100.1750 1B7S-30-01-1.7-71GJL1313001R7011100.175DC operation 17 ... 32 V / 2.8 W4203300 V / 12 A17 ... 321 0B6S-30-10-2.8-72GJL1213001R7102100.1750 1B6S-30-01-2.8-72GJL1213001R7012100.1755.5205600 V / 16 A17 ... 321 0B7S-30-10-2.8-72GJL1313001R7102100.1750 1B7S-30-01-2.8-72GJL1313001R7012100.175Other types on request 2CDC211040F0011BC6-30-10 2CDC211013F0011BC7-30-10Main dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"BC6, BC704
2CDC102009C0201 ABB MOTOR PROTECTION AND CONTROL 4/15—B6, B7 4-pole mini contactors – with screw terminals4 to 5.5 kWAC operatedB6, B7 4-pole mini contactors are compact control products mainly used for switching resistive loads up to 690 V AC.These contactors are designed with:4 main poles• control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories• designed for rail or wall mountingIECUL/CSARated control circuit voltageUC50/60 HzAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operationalcurrent θ ≤ 40 °CAC-1General use ratingAV ACkg4 N.O. main poles20300 V / 12 A240 0B6-40-00-01GJL1211201R0001100.175420 0B6-40-00-02GJL1211201R0002100.175480 0B6-40-00-03GJL1211201R0003100.175110 ... 1270 0B6-40-00-84GJL1211201R8004100.175220 ... 2400 0B6-40-00-80GJL1211201R8000100.17520600 V / 16 A240 0B7-40-00-01GJL1311201R0001100.175420 0B7-40-00-02GJL1311201R0002100.175480 0B7-40-00-03GJL1311201R0003100.175110 ... 1270 0B7-40-00-84GJL1311201R8004100.175220 ... 2400 0B7-40-00-80GJL1311201R8000100.1752 N.O. + 2 N.C. main poles20300 V / 12 A240 0B6-22-00-01GJL1211501R0001100.175420 0B6-22-00-02GJL1211501R0002100.175480 0B6-22-00-03GJL1211501R0003100.175110 ... 1270 0B6-22-00-84GJL1211501R8004100.175220 ... 2400 0B6-22-00-80GJL1211501R8000100.17520600 V / 16 A240 0B7-22-00-01GJL1311501R0001100.175420 0B7-22-00-02GJL1311501R0002100.175480 0B7-22-00-03GJL1311501R0003100.175110 ... 1270 0B7-22-00-84GJL1311501R8004100.175220 ... 2400 0B7-22-00-80GJL1311501R8000100.175Other types on request 2CDC211028F0011B6-22-00Main dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"B6, B704
2CDC102021C02014/16ABB MOTOR PROTECTION AND CONTROL—BC6, B7D 4-pole mini contactors – with screw terminals4 to 5.5 kWDC operatedBC6, B7D 4-pole mini contactors are compact control products mainly used for switching resistive loads up to 690 V AC.These contactors are designed with:•4 main poles•control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for front or side mounting•designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operationalcurrent θ ≤ 40 °CAC-1General use ratingAV DCkg4 N.O. main poles20600 V / 16 A240 0B7D-40-00-01GJL1317201R0001100.1752200 0B7D-40-00-05GJL1317201R0005100.1752 N.O. + 2 N.C. main poles20300 V / 12 A120 0BC6-22-00-07GJL1213501R0007100.175240 0BC6-22-00-01GJL1213501R0001100.175420 0BC6-22-00-02GJL1213501R0002100.175480 0BC6-22-00-16GJL1213501R1006100.175600 0BC6-22-00-03GJL1213501R0003100.175110 ... 1250 0BC6-22-00-04GJL1213501R0004100.175220 ... 2400 0BC6-22-00-05GJL1213501R0005100.175Other types on request 2CDC211032F0011BC6-22-00Main dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"BC6, B7D04
2CDC102011C0201 ABB MOTOR PROTECTION AND CONTROL 4/17—K6 4-pole mini contactor relays – with screw terminalsAC operated K6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to AC-15 4 A / 240 V.These contactors are designed with:• 4-poles with various contact combinations• control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front or side mounting• designed for rail or wall mountingRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)50 Hz60 HzV ACV ACkgK6 4-pole mini contactor relays2424K6-22Z-01GJH1211001R0221100.1754242K6-22Z-02GJH1211001R0222100.1754848K6-22Z-03GJH1211001R0223100.175110 ...127110 ...127K6-22Z-84GJH1211001R8224100.175220 ... 240220 ... 240K6-22Z-80GJH1211001R8220100.175380 ... 415380 ... 415K6-22Z-85GJH1211001R8225100.1752424K6-31Z-01GJH1211001R0311100.1754242K6-31Z-02GJH1211001R0312100.1754848K6-31Z-03GJH1211001R0313100.175110 ...127110 ...127K6-31Z-84GJH1211001R8314100.175220 ... 240220 ... 240K6-31Z-80GJH1211001R8310100.175380 ... 415380 ... 415K6-31Z-85GJH1211001R8315100.1752424K6-40E-01GJH1211001R0401100.1754242K6-40E-02GJH1211001R0402100.1754848K6-40E-03GJH1211001R0403100.175110 ...127110 ...127K6-40E-84GJH1211001R8404100.175220 ... 240220 ... 240K6-40E-80GJH1211001R8400100.175380 ... 415380 ... 415K6-40E-85GJH1211001R8405100.175Other types on request 2CDC211012F0011K6-22Z 2CDC211004F0010K6-31ZMain dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"K604
2CDC102012C02014/18 ABB MOTOR PROTECTION AND CONTROL—KC6 4-pole mini contactor relays – with screw terminalsDC operatedKC6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to AC-15 4 A / 240 V.These contactors are designed with:• 4-poles with various contact combinations• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for front or side mounting• designed for rail or wall mountingRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)V DCkgKC6 4-pole mini contactor relays12KC6-22Z-07GJH1213001R0227100.17524KC6-22Z-01GJH1213001R0221100.17548KC6-22Z-16GJH1213001R1226100.17560KC6-22Z-03GJH1213001R0223100.175110 ... 125KC6-22Z-04GJH1213001R0224100.175220 ... 240KC6-22Z-05GJH1213001R0225100.17512KC6-31Z-07GJH1213001R0317100.17524KC6-31Z-01GJH1213001R0311100.17548KC6-31Z-16GJH1213001R1316100.17560KC6-31Z-03GJH1213001R0313100.175110 ... 125KC6-31Z-04GJH1213001R0314100.175220 ... 240KC6-31Z-05GJH1213001R0315100.17512KC6-40E-07GJH1213001R0407100.17524KC6-40E-01GJH1213001R0401100.17548KC6-40E-16GJH1213001R1406100.17560KC6-40E-03GJH1213001R0403100.175110 ... 125KC6-40E-04GJH1213001R0404100.175220 ... 240KC6-40E-05GJH1213001R0405100.175Other types on request 2CDC211016F0011KC6-22ZMain dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"KC604
2CDC102013C0201 ABB MOTOR PROTECTION AND CONTROL 4/19—KC6 4-pole interface mini contactor relays – with screw terminalsDC operatedKC6 4-pole interface mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to AC-15 4 A / 240 V.These contactors are designed with:• 4-poles with various contact combinations• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs• hum-free coil• no auxiliary contact block permitted for mounting • designed for rail or wall mountingRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)V DCkgDC operation 24 V / 1.4 W24KC6-31Z-1.4-81GJH1213001R8311100.17524KC6-40E-1.4-81GJH1213001R8401100.175DC operation 17 ... 32 V / 2.4 W17 ... 32KC6-31Z-2.4-51GJH1213001R5311100.17517 ... 32KC6-40E-2.4-51GJH1213001R5401100.175Connection to PLCs with integrated protective circuitDC operation 24 V / 1.7 W24K6S-22Z-1.7-71GJH1213001R7221100.17524K6S-31Z-1.7-71GJH1213001R7311100.17524K6S-40E-1.7-71GJH1213001R7401100.175DC operation 17 ... 32 V / 2.8 W17 ... 32K6S-22Z-2.8-72GJH1213001R7222100.17517 ... 32K6S-31Z-2.8-72GJH1213001R7312100.17517 ... 32K6S-40E-2.8-72GJH1213001R7402100.175Other types on request 2CDC211017F0011KC6-31ZMain dimensions mm, inches47.5 1.87"52.5 2.07"57.5 2.26"42.2 1.66"45.2 1.78"4.5 0.18"43.7 1.72"46.7 1.84"KC604
2CDC102023C02014/20ABB MOTOR PROTECTION AND CONTROL—B6, B7 3-pole mini contactors – with soldering pins4 to 5.5 kWAC operatedB6..P and B7..P 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:•3 main poles and one built-in auxiliary contact•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for side mounting•designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgB6 mini contactors4123300 V / 12 A24241 0B6-30-10-P-01GJL1211009R0101100.1700 1B6-30-01-P-01GJL1211009R0011100.17042421 0B6-30-10-P-02GJL1211009R0102100.1700 1B6-30-01-P-02GJL1211009R0012100.17048481 0B6-30-10-P-03GJL1211009R0103100.1700 1B6-30-01-P-03GJL1211009R0013100.170110 ... 127 110 ... 127 1 0B6-30-10-P-84GJL1211009R8104100.1700 1B6-30-01-P-84GJL1211009R8014100.170220 ... 240 220 ... 240 1 0B6-30-10-P-80GJL1211009R8100100.1700 1B6-30-01-P-80GJL1211009R8010100.170380 ... 415 380 ... 415 1 0B6-30-10-P-85GJL1211009R8105100.1700 1B6-30-01-P-85GJL1211009R8015100.170B7 mini contactors5.5125600 V / 16 A24241 0B7-30-10-P-01GJL1311009R0101100.1700 1B7-30-01-P-01GJL1311009R0011100.17042421 0B7-30-10-P-02GJL1311009R0102100.1700 1B7-30-01-P-02GJL1311009R0012100.17048481 0B7-30-10-P-03GJL1311009R0103100.1700 1B7-30-01-P-03GJL1311009R0013100.170110 ... 127 110 ... 127 1 0B7-30-10-P-84GJL1311009R8104100.1700 1B7-30-01-P-84GJL1311009R8014100.170220 ... 240 220 ... 240 1 0B7-30-10-P-80GJL1311009R8100100.1700 1B7-30-01-P-80GJL1311009R8010100.170380 ... 415 380 ... 415 1 0B7-30-10-P-85GJL1311009R8105100.1700 1B7-30-01-P-85GJL1311009R8015100.170Other types on request 2CDC211003F0010B6-30-10-P 2CDC211011F0011B7-30-10-PMain dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"B6, B704
2CDC102024C0201 ABB MOTOR PROTECTION AND CONTROL 4/21—BC6, BC7 3-pole mini contactors – with soldering pins4 to 5.5 kWDC operatedB6..P and B7..P 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:• 3 main poles and one built-in auxiliary contact• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for side mounting• designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgBC6 mini contactors with 3 N.O. main poles4123300 V / 12 A121 0BC6-30-10-P-07GJL1213009R0107100.1700 1BC6-30-01-P-07GJL1213009R0017100.170241 0BC6-30-10-P-01GJL1213009R0101100.1700 1BC6-30-01-P-01GJL1213009R0011100.170481 0BC6-30-10-P-16GJL1213009R1106100.1700 1BC6-30-01-P-16GJL1213009R1016100.170601 0BC6-30-10-P-03GJL1213009R0103100.1700 1BC6-30-01-P-03GJL1213009R0013100.170110 ... 1251 0BC6-30-10-P-04GJL1213009R0104100.1700 1BC6-30-01-P-04GJL1213009R0014100.170220 ... 2401 0BC6-30-10-P-05GJL1213009R0105100.1700 1BC6-30-01-P-05GJL1213009R0015100.170BC7 mini contactors with 3 N.O. main poles5.5125600 V / 16 A121 0BC7-30-10-P-07GJL1313009R0107100.1700 1BC7-30-01-P-07GJL1313009R0017100.170241 0BC7-30-10-P-01GJL1313009R0101100.1700 1BC7-30-01-P-01GJL1313009R0011100.170481 0BC7-30-10-P-16GJL1313009R1106100.1700 1BC7-30-01-P-16GJL1313009R1016100.170601 0BC7-30-10-P-03GJL1313009R0103100.1700 1BC7-30-01-P-03GJL1313009R0013100.170110 ... 1251 0BC7-30-10-P-04GJL1313009R0104100.1700 1BC7-30-01-P-04GJL1313009R0014100.170220 ... 2401 0BC7-30-10-P-05GJL1313009R0105100.1700 1BC7-30-01-P-05GJL1313009R0015100.170BC6 mini contactors 2 N.O. + 1 N.C. main poles4123300 V / 12 A241 0BC6-21-10-P-01GJL1213109R0101100.170481 0BC6-21-10-P-16GJL1213109R1106100.170601 0BC6-21-10-P-03GJL1213109R0103100.170110 ... 1251 0BC6-21-10-P-04GJL1213109R0104100.170220 ... 2401 0BC6-21-10-P-05GJL1213109R0105100.170Other types on request 2CDC211030F0011BC7-30-10-PMain dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"B6, B704
2CDC102025C02014/22ABB MOTOR PROTECTION AND CONTROL—VB6, VB7 3-pole mini reversing contactors – with soldering pins 4 to 5.5 kWAC operatedVB6..P, VB7..P 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:•built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•no auxiliary contact block permitted for mounting•designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgVB6 mini reversing contactors4123300 V / 12 A24241 0VB6-30-10-P-01GJL1211909R010150.3450 1VB6-30-01-P-01GJL1211909R001150.34542421 0VB6-30-10-P-02GJL1211909R010250.3450 1VB6-30-01-P-02GJL1211909R001250.34548481 0VB6-30-10-P-03GJL1211909R010350.3450 1VB6-30-01-P-03GJL1211909R001350.345110 ... 127 110 ... 127 1 0VB6-30-10-P-84GJL1211909R810450.3450 1VB6-30-01-P-84GJL1211909R801450.345220 ... 240 220 ... 240 1 0VB6-30-10-P-80GJL1211909R810050.3450 1VB6-30-01-P-80GJL1211909R801050.345380 ... 415 380 ... 415 1 0VB6-30-10-P-85GJL1211909R810550.3450 1VB6-30-01-P-85GJL1211909R801550.345VB7 mini reversing contactors5.5125600 V / 16 A24241 0VB7-30-10-P-01GJL1311909R010150.3450 1VB7-30-01-P-01GJL1311909R001150.34542421 0VB7-30-10-P-02GJL1311909R010250.3450 1VB7-30-01-P-02GJL1311909R001250.34548481 0VB7-30-10-P-03GJL1311909R010350.3450 1VB7-30-01-P-03GJL1311909R001350.345110 ... 127 110 ... 127 1 0VB7-30-10-P-84GJL1311909R810450.3450 1VB7-30-01-P-84GJL1311909R801450.345220 ... 240 220 ... 240 1 0VB7-30-10-P-80GJL1311909R810050.3450 1VB7-30-01-P-80GJL1311909R801050.345380 ... 415 380 ... 415 1 0VB7-30-10-P-85GJL1311909R810550.3450 1VB7-30-01-P-85GJL1311909R801550.345Other types on request 2CDC211010S0011VB7-30-10-PMain dimensions mm, inches45.2 1.78"57.5 2.26"96.2 3.79"44.7 1.76"47.7 1.88"4.3 0.17"1 0.04"4.5 0.18"42.2 1.66"VB6, VB704
2CDC102026C0201 ABB MOTOR PROTECTION AND CONTROL 4/23—VBC6, VBC7 3-pole mini reversing contactors – with soldering pins 4 to 5.5 kWDC operatedVBC6..P, VBC7..P 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• no auxiliary contact block permitted for mounting• designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC6 mini reversing contactors4123300 V / 12 A121 0VBC6-30-10-P-07GJL1213909R010750.3450 1VBC6-30-01-P-07GJL1213909R001750.345241 0VBC6-30-10-P-01GJL1213909R010150.3450 1VBC6-30-01-P-01GJL1213909R001150.345481 0 VBC6-30-10-P-06 GJL1213909R010650.3450 1VBC6-30-06-P-06GJL1213909R001650.345601 0VBC6-30-10-P-03GJL1213909R010350.3450 1VBC6-30-01-P-03GJL1213909R001350.345110 ... 1251 0VBC6-30-10-P-04GJL1213909R010450.3450 1VBC6-30-01-P-04GJL1213909R001450.345220 ... 2401 0VBC6-30-10-P-05GJL1213909R010550.3450 1VBC6-30-01-P-05GJL1213909R001550.345VBC7 mini reversing contactors5.5125600 V / 16 A121 0VBC7-30-10-P-07GJL1313909R010750.3450 1VBC7-30-01-P-07GJL1313909R001750.345241 0VBC7-30-10-P-01GJL1313909R010150.3450 1VBC7-30-01-P-01GJL1313909R001150.345481 0VBC7-30-10-P-16GJL1313909R110650.3450 1VBC7-30-01-P-16GJL1313909R101650.345601 0VBC7-30-10-P-03GJL1313909R010350.3450 1VBC7-30-01-P-03GJL1313909R001350.345110 ... 1251 0VBC7-30-10-P-04GJL1313909R010450.3450 1VBC7-30-01-P-04GJL1313909R001450.345220 ... 2401 0VBC7-30-10-P-05GJL1313909R010550.3450 1VBC7-30-01-P-05GJL1313909R001550.345Other types on request 2CDC211009F0011VBC7-30-10-PMain dimensions mm, inches45.2 1.78"57.5 2.26"96.2 3.79"44.7 1.76"47.7 1.88"4.3 0.17"1 0.04"4.5 0.18"42.2 1.66"VBC6, VBC704
2CDC102027C02014/24ABB MOTOR PROTECTION AND CONTROL—VB6A, VB7A 3-pole mini reversing contactors – with soldering pins4 to 5.5 kWAC operated – with safety blocking functionVB6A..P, VB7A..P 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:•built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•no auxiliary contact block permitted for mounting•designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgVB6A mini reversing contactors with safety blocking function4123300 V / 12 A24241 0VB6A-30-10-P-01GJL1211919R010150.3450 1VB6A-30-01-P-01GJL1211919R001150.34542421 0VB6A-30-10-P-02GJL1211919R010250.3450 1VB6A-30-01-P-02GJL1211919R001250.34548481 0VB6A-30-10-P-03GJL1211919R010350.3450 1VB6A-30-01-P-03GJL1211919R001350.345110 ... 127 110 ... 127 1 0VB6A-30-10-P-84GJL1211919R810450.3450 1VB6A-30-01-P-84GJL1211919R801450.345220 ... 240 220 ... 240 1 0VB6A-30-10-P-80GJL1211919R810050.3450 1VB6A-30-01-P-80GJL1211919R801050.345380 ... 415 380 ... 415 1 0VB6A-30-10-P-85GJL1211919R810550.3450 1VB6A-30-01-P-85GJL1211919R801550.345VB7A mini reversing contactors with safety blocking function5.5125600 V / 16 A24241 0VB7A-30-10-P-01GJL1311919R010150.3450 1VB7A-30-01-P-01GJL1311919R001150.34542421 0VB7A-30-10-P-02GJL1311919R010250.3450 1VB7A-30-01-P-02GJL1311919R001250.34548481 0VB7A-30-10-P-03GJL1311919R010350.3450 1VB7A-30-01-P-03GJL1311919R001350.345110 ... 127 110 ... 127 1 0VB7A-30-10-P-84GJL1311919R810450.3450 1VB7A-30-01-P-84GJL1311919R801450.345220 ... 240 220 ... 240 1 0VB7A-30-10-P-80GJL1311919R810050.3450 1VB7A-30-01-P-80GJL1311919R801050.345380 ... 415 380 ... 415 1 0VB7A-30-10-P-85GJL1311919R810550.3450 1VB7A-30-01-P-85GJL1311919R801550.345Other types on request 2CDC211013F0010VB7-30-01-PMain dimensions mm, inches45.2 1.78"57.5 2.26"96.2 3.79"44.7 1.76"47.7 1.88"4.3 0.17"1 0.04"4.5 0.18"42.2 1.66"VB6A, VB7A04
2CDC102028C0201 ABB MOTOR PROTECTION AND CONTROL 4/25—VBC7A 3-pole mini reversing contactors – with soldering pins4 to 5.5 kWDC operated – with safety blocking functionVBC7A..P 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.• control circuit: AC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• no auxiliary contact block permitted for mounting• designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC7A mini reversing contactors with safety blocking function5.5125600 V / 16 A121 0VBC7A-30-10-P-07GJL1313919R010750.3450 1VBC7A-30-01-P-07GJL1313919R001750.345241 0VBC7A-30-10-P-01GJL1313919R010150.3450 1VBC7A-30-01-P-01GJL1313919R001150.345481 0VBC7A-30-10-P-16GJL1313919R110650.3450 1VBC7A-30-01-P-16GJL1313919R101650.345601 0VBC7A-30-10-P-03GJL1313919R010350.3450 1VBC7A-30-01-P-03GJL1313919R001350.345110 ... 1251 0VBC7A-30-10-P-04GJL1313919R010450.3450 1VBC7A-30-01-P-04GJL1313919R001450.345220 ... 2401 0VBC7A-30-10-P-05GJL1313919R010550.3450 1VBC7A-30-01-P-05GJL1313919R001550.345Other types on request 2CDC211009F0011VBC7A-30-10-P45.2 1.78"57.5 2.26"96.2 3.79"44.7 1.76"47.7 1.88"4.3 0.17"1 0.04"4.5 0.18"42.2 1.66"VBC7AMain dimensions mm, inches04
2CDC102029C02014/26ABB MOTOR PROTECTION AND CONTROL—BC6, BC7 3-pole interface mini contactors – with soldering pins4 to 5.5 kWDC operatedBC6..P, BC7..P 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with: •3 main poles and one built-in auxiliary contact• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs•hum-free coil•no auxiliary contact block permitted for mounting•designed for soldering on PCB boardsIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgDC operation 24 V / 1.4 W4123300 V / 12 A241 0BC6-30-10-P-1.4-81GJL1213009R8101100.1700 1BC6-30-01-P-1.4-81GJL1213009R8011100.1705.5125600 V / 16 A241 0BC7-30-10-P-1.4-81GJL1313009R8101100.1700 1BC7-30-01-P-1.4-81GJL1313009R8011100.170DC operation 17 ... 32 V / 2.4 W, Ith < 8 A4123300 V / 12 A17 ... 321 0BC6-30-10-P-2.4-51GJL1213009R5101100.1700 1BC6-30-01-P-2.4-51GJL1213009R5011100.1705.5125600 V / 16 A17 ... 321 0BC7-30-10-P-2.4-51GJL1313009R5101100.1700 1BC7-30-01-P-2.4-51GJL1313009R5011100.170Other types on request2CDC211030F0011BC7-30-10-PMain dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"BC6, BC704
2CDC102030C0201 ABB MOTOR PROTECTION AND CONTROL 4/27—K6 4-pole mini contactor relays – with soldering pinsAC operatedK6..P 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:• 4-poles with various contact combinations• control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)• hum-free coil• add-on auxiliary contact block for side mounting• designed for soldering on PCB boardsRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)50 Hz60 HzV ACV ACkgK6 4-pole mini contactor relays2424K6-22Z-P-01GJH1211009R0221100.1704242K6-22Z-P-02GJH1211009R0222100.1704848K6-22Z-P-03GJH1211009R0223100.170110 ...127110 ...127K6-22Z-P-84GJH1211009R8224100.170220 ... 240220 ... 240K6-22Z-P-80GJH1211009R8220100.170380 ... 415380 ... 415K6-22Z-P-85GJH1211009R8225100.1702424K6-31Z-P-01GJH1211009R0311100.1704242K6-31Z-P-02GJH1211009R0312100.1704848K6-31Z-P-03GJH1211009R0313100.170110 ...127110 ...127K6-31Z-P-84GJH1211009R8314100.170220 ... 240220 ... 240K6-31Z-P-80GJH1211009R8310100.170380 ... 415380 ... 415K6-31Z-P-85GJH1211009R8315100.1702424K6-40E-P-01GJH1211009R0401100.1704242K6-40E-P-02GJH1211009R0402100.1704848K6-40E-P-03GJH1211009R0403100.170110 ...127110 ...127K6-40E-P-84GJH1211009R8404100.170220 ... 240220 ... 240K6-40E-P-80GJH1211009R8400100.170380 ... 415380 ... 415K6-40E-P-85GJH1211009R8405100.170Other types on request 2CDC211022F0011K6-22Z-PMain dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"K604
2CDC102031C02014/28ABB MOTOR PROTECTION AND CONTROL—KC6 4-pole mini contactor relays – with soldering pinsDC operatedKC6..P 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:•4-poles with various contact combinations•control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)•hum-free coil•add-on auxiliary contact block for side mounting•designed for soldering on PCB boardsRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)V DCkgK6 4-pole mini contactor relays12KC6-22Z-P-07GJH1213009R0227100.17024KC6-22Z-P-01GJH1213009R0221100.17048KC6-22Z-P-16GJH1213009R1226100.170110 ... 125KC6-22Z-P-04GJH1213009R0224100.170220 ... 240KC6-22Z-P-05GJH1213009R0225100.17024KC6-31Z-P-01GJH1213009R0311100.17048KC6-31Z-P-16GJH1213009R1316100.170110 ... 125KC6-31Z-P-04GJH1213009R0314100.170220 ... 240KC6-31Z-P-05GJH1213009R0315100.17012KC6-40E-P-07GJH1213009R0407100.17024KC6-40E-P-01GJH1213009R0401100.17048KC6-40E-P-16GJH1213009R1406100.170110 ... 125KC6-40E-P-04GJH1213009R0404100.170220 ... 240KC6-40E-P-05GJH1213009R0405100.170Other types on request 2CDC211025F0011KC6-22Z-P 2CDC211023F0011KC6-31Z-PMain dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"KC604
2CDC102032C0201 ABB MOTOR PROTECTION AND CONTROL 4/29—KC6 4-pole interface mini contactor relays – with solderings pinsDC operatedKC6..P 4-pole interface mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:• 4-poles with various contact combinations• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs• hum-free coil• no auxiliary contact block permitted for mounting• designed for soldering on PCB boardsRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)V DCkgDC operation 24 V / 1.4 W24KC6-31Z-P-1.4-81GJH1213009R8311100.17024KC6-40E-P-1.4-81GJH1213009R8401100.170DC operation 17 ... 32 V / 2.4 W17 ... 32KC6-31Z-P-2.4-51GJH1213009R5311100.17017 ... 32KC6-40E-P-2.4-51GJH1213009R5401100.170Other types on request 2CDC211023F0011KC6-31Z-P-1.4Main dimensions mm, inches1 0.04"47.5 1.87"42.2 1.66"45.2 1.78"44.7 1.76"47.7 1.88"4.3 0.17"KC604
2CDC102033C02014/30ABB MOTOR PROTECTION AND CONTROL—B6, B7 3-pole mini contactors – with flat pin connection4 to 5.5 kWAC operatedB6..F, B7..F 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:•flat pin connection for plug-in wiring and shake proven connection•3 main poles and one built-in auxiliary contact•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for side mounting•designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgB6 mini contactors4203300 V / 12 A24241 0B6-30-10-F-01GJL1211003R0101100.1700 1B6-30-01-F-01GJL1211003R0011100.17042421 0B6-30-10-F-02GJL1211003R0102100.1700 1B6-30-01-F-02GJL1211003R0012100.17048481 0B6-30-10-F-03GJL1211003R0103100.1700 1B6-30-01-F-03GJL1211003R0013100.170110 ... 127 110 ... 1271 0B6-30-10-F-84GJL1211003R8104100.1700 1B6-30-01-F-84GJL1211003R8014100.170220 ... 240 220 ... 2401 0B6-30-10-F-80GJL1211003R8100100.1700 1B6-30-01-F-80GJL1211003R8010100.170380 ... 415 380 ... 4151 0B6-30-10-F-85GJL1211003R8105100.1700 1B6-30-01-F-85GJL1211003R8015100.170B7 mini contactors5.5205600 V / 16 A24241 0B7-30-10-F-01GJL1311003R0101100.1700 1B7-30-01-F-01GJL1311003R0011100.17042421 0B7-30-10-F-02GJL1311003R0102100.1700 1B7-30-01-F-02GJL1311003R0012100.17048481 0B7-30-10-F-03GJL1311003R0103100.1700 1B7-30-01-F-03GJL1311003R0013100.170110 ... 127 110 ... 1271 0B7-30-10-F-84GJL1311003R8104100.1700 1B7-30-01-F-84GJL1311003R8014100.170220 ... 240 220 ... 2401 0B7-30-10-F-80GJL1311003R8100100.1700 1B7-30-01-F-80GJL1311003R8010100.170380 ... 415 380 ... 4151 0B7-30-10-F-85GJL1311003R8105100.1700 1B7-30-01-F-85GJL1311003R8015100.170Other types on request 2CDC211002F0010B6-30-10-F 2CDC211031F0011B7-30-10-FMain dimensions mm, inches57.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"B6, B704
2CDC102034C0201 ABB MOTOR PROTECTION AND CONTROL 4/31—BC6, BC7 3-pole mini contactors – with flat pin connection4 to 5.5 kWDC operatedBC6..F, BC7..F 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:• flat pin connection for plug-in wiring and shake proven connection• 3 main poles and one built-in auxiliary contact• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for side mounting• designed for rail or wall mountingIECUL/CSARated control circuit voltage UCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgBC6 mini contactors4203300 V / 12 A121 0BC6-30-10-F-07GJL1213003R0107100.1700 1BC6-30-01-F-07GJL1213003R0017100.170241 0BC6-30-10-F-01GJL1213003R0101100.1700 1BC6-30-01-F-01GJL1213003R0011100.170481 0BC6-30-10-F-16GJL1213003R1106100.1700 1BC6-30-01-F-16GJL1213003R1016100.170601 0BC6-30-10-F-03GJL1213003R0103100.1700 1BC6-30-01-F-03GJL1213003R0013100.170110 ... 1251 0BC6-30-10-F-04GJL1213003R0104100.1700 1BC6-30-01-F-04GJL1213003R0014100.170220 ... 2401 0BC6-30-10-F-05GJL1213003R0105100.1700 1BC6-30-01-F-05GJL1213003R0015100.170BC7 mini contactors5.5205600 V / 16 A121 0BC7-30-10-F-07GJL1313003R0107100.1700 1BC7-30-01-F-07GJL1313003R0017100.170241 0BC7-30-10-F-01GJL1313003R0101100.1700 1BC7-30-01-F-01GJL1313003R0011100.170481 0BC7-30-10-F-16GJL1313003R1106100.1700 1BC7-30-01-F-16GJL1313003R1016100.170601 0BC7-30-10-F-03GJL1313003R0103100.1700 1BC7-30-01-F-03GJL1313003R0013100.170110 ... 1251 0BC7-30-10-F-04GJL1313003R0104100.1700 1BC7-30-01-F-04GJL1313003R0014100.170220 ... 2401 0BC7-30-10-F-05GJL1313003R0105100.1700 1BC7-30-01-F-05GJL1313003R0015100.170Other types on request 2CDC211041F0011BC6-30-10-F 2CDC211024F0011BC7-30-10-FMain dimensions mm, inches57.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"BC6, BC704
2CDC102035C02014/32ABB MOTOR PROTECTION AND CONTROL—VB7 3-pole mini reversing contactors – with flat pin connection 4 to 5.5 kWAC operatedVB7..F 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:•built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc.•flat pin connection for plug-in wiring and shake proven connection•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•no auxiliary contact block permitted for mounting•designed for rail and wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACkgVB7 mini reversing contactors5.5205600 V / 16 A24241 0VB7-30-10-F-01GJL1311903R010150.3450 1VB7-30-01-F-01GJL1311903R001150.34542421 0VB7-30-10-F-02GJL1311903R010250.3450 1VB7-30-01-F-02GJL1311903R001250.34548481 0VB7-30-10-F-03GJL1311903R010350.3450 1VB7-30-01-F-03GJL1311903R001350.345110 ... 127 110 ... 127 1 0VB7-30-10-F-84GJL1311903R810450.3450 1VB7-30-01-F-84GJL1311903R801450.345220 ... 240 220 ... 240 1 0VB7-30-10-F-80GJL1311903R810050.3450 1VB7-30-01-F-80GJL1311903R801050.345380 ... 415 380 ... 415 1 0VB7-30-10-F-85GJL1311903R810550.3450 1VB7-30-01-F-85GJL1311903R801550.345Other types on request 2CDC211005F0011VB7-30-10-FMain dimensions mm, inches43.7 1.72"46.7 1.84"4.5 0.18"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VB704
2CDC102036C0201 ABB MOTOR PROTECTION AND CONTROL 4/33—VBC7 3-pole mini reversing contactors – with flat pin connection 4 to 5.5 kWDC operatedVBC7..F 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be de-energised for 50 ms at least to prevent phase to phase short circuit on the arc• flat pin connection for plug-in wiring and shake proven connection• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• no auxiliary contact block permitted for mounting• designed for rail and wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC7 mini reversing contactors5.5205600 V / 16 A121 0VBC7-30-10-F-07GJL1313903R010750.3450 1VBC7-30-01-F-07GJL1313903R001750.345241 0VBC7-30-10-F-01GJL1313903R010150.3450 1VBC7-30-01-F-01GJL1313903R001150.345481 0VBC7-30-10-F-16GJL1313903R110650.3450 1VBC7-30-01-F-16GJL1313903R101650.345601 0VBC7-30-10-F-03GJL1313903R010350.3450 1VBC7-30-01-F-03GJL1313903R001350.345110 ... 1251 0VBC7-30-10-F-04GJL1313903R010450.3450 1VBC7-30-01-F-04GJL1313903R001450.345220 ... 2401 0VBC7-30-10-F-05GJL1313903R010550.3450 1VBC7-30-01-F-05GJL1313903R001550.345Other types on request2CDC211004F0011VBC7-30-10-F43.7 1.72"46.7 1.84"4.5 0.18"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VBC7Main dimensions mm, inches04
2CDC102037C02014/34ABB MOTOR PROTECTION AND CONTROL—VB7A 3-pole mini reversing contactors – with flat pin connection4 to 5.5 kWAC operated – with safety blocking functionVB7A..F 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:•built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.•flat pin connection for plug-in wiring and shake proven connection•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•no auxiliary contact block permitted for mounting•designed for rail and wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-150 Hz60 HzkWAhpV ACV ACpcekgVB7A mini reversing contactors with safety blocking function5.5205600 V / 16 A24241 0VB7A-30-10-F-01GJL1311913R010150.3450 1VB7A-30-01-F-01GJL1311913R001150.34542421 0VB7A-30-10-F-02GJL1311913R010250.3450 1VB7A-30-01-F-02GJL1311913R001250.34548481 0VB7A-30-10-F-03GJL1311913R010350.3450 1VB7A-30-01-F-03GJL1311913R001350.345110 ... 127 110 ... 127 1 0VB7A-30-10-F-84GJL1311913R810450.3450 1VB7A-30-01-F-84GJL1311913R801450.345220 ... 240 220 ... 240 1 0VB7A-30-10-F-80GJL1311913R810050.3450 1VB7A-30-01-F-80GJL1311913R801050.345380 ... 415 380 ... 415 1 0VB7A-30-10-F-85GJL1311913R810550.3450 1VB7A-30-01-F-85GJL1311913R801550.345Other types on request 2CDC211003F0011VB7A-30-10-F43.7 1.72"46.7 1.84"4.5 0.18"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VB7AMain dimensions mm, inches04
2CDC102038C0201 ABB MOTOR PROTECTION AND CONTROL 4/35—VBC7A 3-pole mini reversing contactors – with flat pin connection4 to 5.5 kWDC operated – with safety blocking functionVBC7A..F 3-pole compact design reversing contactors are space optimized control products mainly used for switching resistive or motor loads up to 690 V AC.These reversing contactors are designed with:• built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the voltage is applied to the coil of the contactor to be switched on before the contactor to be switched off has dropped out. The contactor coils are designed for continuous operation when the contactor is de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor with the coil voltage applied.• flat pin connection for plug-in wiring and shake proven connection• control circuit: DC operated, low coil consumption (3.5 W at pull-in and at holding)• hum-free coil• no auxiliary contact block permitted for mounting• designed for rail and wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phase motor rating 480 VGeneral use ratingpower400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgVBC7A mini reversing contactors with safety blocking function5.5205600 V / 16 A121 0VBC7A-30-10-F-07GJL1313913R010750.3450 1VBC7A-30-01-F-07GJL1313913R001750.345241 0VBC7A-30-10-F-01GJL1313913R010150.3450 1VBC7A-30-01-F-01GJL1313913R001150.345481 0VBC7A-30-10-F-16GJL1313913R110650.3450 1VBC7A-30-01-F-16GJL1313913R101650.345601 0VBC7A-30-10-F-03GJL1313913R010350.3450 1VBC7A-30-01-F-03GJL1313913R001350.345110 ... 1251 0VBC7A-30-10-F-04GJL1313913R010450.3450 1VBC7A-30-01-F-04GJL1313913R001450.345220 ... 2401 0VBC7A-30-10-F-05GJL1313913R010550.3450 1VBC7A-30-01-F-05GJL1313913R001550.345Other types on request 2CDC211002F0011VBC7A-30-10-F43.7 1.72"46.7 1.84"4.5 0.18"96.2 3.79"42.2 1.66"45.2 1.78"57.5 2.26"VBC7AMain dimensions mm, inches04
2CDC102039C02014/36ABB MOTOR PROTECTION AND CONTROL—BC6, BC7 3-pole interface mini contactors – with flat pin connection4 to 5.5 kWDC operatedBC6..F, BC7..F 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.These contactors are designed with:•flat pin connection for plug-in wiring and shake proven connection •3 main poles and one built-in auxiliary contact• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs•hum-free coil•no auxiliary contact block permitted for mounting•designed for rail or wall mountingIECUL/CSARated control circuit voltageUCAuxiliarycontactsfittedTy pe Order codePkg qtyWeight(1 pce)Rated operational3-phasemotor rating 480 VGeneral use ratingpower 400 V AC-3current θ ≤ 40 °C AC-1kWAhpV DCkgDC operation 24 V / 1.4 W4203300 V / 12 A241 0BC6-30-10-F-1.4-81GJL1213003R8101100.1700 1BC6-30-01-F-1.4-81GJL1213003R8011100.1705.5205600 V / 16 A241 0BC7-30-10-F-1.4-81GJL1313003R8101100.1700 1BC7-30-01-F-1.4-81GJL1313003R8011100.170DC operation 17 ... 32 V / 2.4 W4203300 V / 12 A17 ... 321 0BC6-30-10-F-2.4-51GJL1213003R5101100.1700 1BC6-30-01-F-2.4-51GJL1213003R5011100.1705.5205600 V / 16 A17 ... 321 0BC7-30-10-F-2.4-51GJL1313003R5101100.1700 1BC7-30-01-F-2.4-51GJL1313003R5011100.170Other types on request 2CDC211041F0011BC6-30-10-F 2CDC211024F0011BC7-30-10-F57.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"BC6, BC7Main dimensions mm, inches04
2CDC102040C0201 ABB MOTOR PROTECTION AND CONTROL 4/37—K6 4-pole mini contactor relays – with flat pin connectionAC operatedK6..F 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:• flat pin connection for plug-in wiring and shake proven connection• 4-poles with various contact combinations• control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)• hum-free coil• add-on auxiliary contact blocks for side mounting• designed for rail and wall mountingRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)50 Hz60 HzV ACV ACkgK6 4-pole mini contactor relays2424K6-22Z-F-01GJH1211003R0221100.1704242K6-22Z-F-02GJH1211003R0222100.1704848K6-22Z-F-03GJH1211003R0223100.170110 ...127110 ...127K6-22Z-F-84GJH1211003R8224100.170220 ... 240220 ... 240K6-22Z-F-80GJH1211003R8220100.170380 ... 415380 ... 415K6-22Z-F-85GJH1211003R8225100.1702424K6-31Z-F-01GJH1211003R0311100.1704242K6-31Z-F-02GJH1211003R0312100.1704848K6-31Z-F-03GJH1211003R0313100.170110 ...127110 ...127K6-31Z-F-84GJH1211003R8314100.170220 ... 240220 ... 240K6-31Z-F-80GJH1211003R8310100.170380 ... 415380 ... 415K6-31Z-F-85GJH1211003R8315100.1702424K6-40E-F-01GJH1211003R0401100.1704242K6-40E-F-02GJH1211003R0402100.1704848K6-40E-F-03GJH1211003R0403100.170110 ...127110 ...127K6-40E-F-84GJH1211003R8404100.170220 ... 240220 ... 240K6-40E-F-80GJH1211003R8400100.170380 ... 415380 ... 415K6-40E-F-85GJH1211003R8405100.170Other types on request 2CDC211034S0011K6-22Z-F57.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"K6Main dimensions mm, inches04
2CDC102041C02014/38ABB MOTOR PROTECTION AND CONTROL—KC6 4-pole mini contactor relays – with flat pin connectionDC operatedK6..F 4-pole mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:•flat pin connection for plug-in wiring and shake proven connection•4-poles with various contact combinations•control circuit: AC operated, low coil consumption (3.5 VA at pull-in and at holding)•hum-free coil•add-on auxiliary contact blocks for side mounting•designed for rail and wall mountingRated control circuit voltageUCTy pe Order codePkg qtyWeight (1 pce)V DCkgK6 4-pole mini contactor relays12KC6-22Z-F-07GJH1213003R0227100.17024KC6-22Z-F-01GJH1213003R0221100.17048KC6-22Z-F-16GJH1213003R1226100.170110 ... 125KC6-22Z-F-04GJH1213003R0224100.170220 ... 240KC6-22Z-F-05GJH1213003R0225100.17012KC6-31Z-F-07GJH1213003R0317100.17024KC6-31Z-F-01GJH1213003R0311100.17048KC6-31Z-F-16GJH1213003R1316100.170110 ... 125KC6-31Z-F-04GJH1213003R0314100.170220 ... 240KC6-31Z-F-05GJH1213003R0315100.170 24KC6-40E-F-01GJH1213003R0401100.17048KC6-40E-F-16GJH1213003R1406100.170110 ... 125KC6-40E-F-04GJH1213003R0404100.170220 ... 240KC6-40E-F-05GJH1213003R0405100.170Other types on request 2CDC211029F0011KC6-22Z-F-0157.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"KC6Main dimensions mm, inches04
2CDC102045C0201 ABB MOTOR PROTECTION AND CONTROL 4/39—KC6 4-pole interface mini contactor relays – with flat pin connectionDC operatedKC6..F 4-pole interface mini-contactor relays are space optimized control products mainly used for control functions or for small loads up to 4 A.These contactors are designed with:• flat pin connection for plug-in wiring and shake proven connection• 4-poles with various contact combinations• control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC-outputs• hum-free coil• no auxiliary contact block permitted for mounting• designed for rail and wall mountingRated control circuit voltage UCTy pe Order codePkg qtyWeight (1 pce)V DCkgDC operation 24 V / 1.4 W24KC6-31Z-F-1.4-81GJH1213003R8311100.17024KC6-40E-F-1.4-81GJH1213003R8401100.170DC operation 17 ... 32 V / 2.4 W17 ... 32KC6-31Z-F-51GJH1213003R5311100.17017 ... 32KC6-40E-F-51GJH1213003R5401100.170Other types on request 2CDC211033F0011KC6-31Z-F-05Main dimensions mm, inches57.5 2.26"45.2 1.78"47.5 1.87"52.5 2.07"43.7 1.72"46.7 1.84"42.2 1.66"4.5 0.18"KC604
2CDC102043C02014/4 0ABB MOTOR PROTECTION AND CONTROL—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical dataMain pole – Utilization characteristics according to IECContactor typesAC operatedB6, VB6, VB6AB7, VB7, VB7ADC operatedBC6, VBC6, VBC6ABC7, VBC7, VBC7AStandardsIEC/EN 60947-1, IEC/EN 60947-4-1Rated operational voltage Ue max690 V ACRated frequency (without derating)DC or 50 / 60 HzConventional free-air thermal current lth acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C, with conductor cross-sectional areaScrew terminal types: 20 AFlat pin types: 20 ASoldering pin types: 12 AAC-1 Utilization category for air temperature close to contactor θ ≤ 40 °CIe / Rated operational current AC-1 Ue max ≤ 690 V, 50/60 Hz220-230-240 V Screw terminal types: 20 AFlat pin types: 20 ASoldering pin types: 12 A380-400 V Screw terminal types: 20 AFlat pin types: 20 ASoldering pin types: 12 A440 V Screw terminal types: 20 AFlat pin types: 20 ASoldering pin types: 12 A500 V 12 A690 V 6 AAC-1 Utilization category for air temperature close to contactor θ ≤ 55 °CIe / Rated operational current AC-1 Ue max ≤ 690 V, 50/60 Hz220-230-240 V Screw terminal types: 16 AFlat pin types: 16 ASoldering pin types: 12 A380-400 V Screw terminal types: 16 AFlat pin types: 16 ASoldering pin types: 12 A440 V Screw terminal types: 16 AFlat pin types: 16 ASoldering pin types: 12 A500 V 12 A690 V 6 AAC-3 Utilization category for air temperature close to contactor θ ≤ 55 °CIe / Rated operational current AC-3 220 / 230 / 240 V 8.9 / 8.5 / 8.1 A11.8 / 11.3 / 10.8 A3-phase motorsM3380 / 400 V 8.9 / 8.5 A12.1 / 11.5 A440 V 7.4 A10.1 A500 V 6.8 A9.2 A690 V 3.8 A3.8 ARated operational power AC-3220-230-240 V 2.2 kW3 kWM31500 r.p.m. 50 Hz1800 r.p.m. 60 Hz3-phase motors380-400 V 4 kW5.5 kW440 V 4 kW5.5 kW500 V 4 kW5.5 kW690 V 3 kW3 kWDC-1 Utilization category for air temperature close to contactor θ ≤ 55 °CIe / Rated operational current DC-1110 V-4 A220 V-0.6 ADC-3 Utilization category for air temperature close to contactor θ ≤ 55 °CIe / Rated operational current DC-3110 V-1.5 A220 V-0.25 ADC-5 Utilization category for air temperature close to contactor θ ≤ 55 °CIe / Rated operational current DC-5110 V-0.4 A220 V-0.2 ARated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1Short-circuit protection device for contactorswithout thermal O/L relay - motor protection excluded Ue ≤ 500 V AC - fuse type gGType 1: 25 A / Type 2: 25 ARated short-time withstand current ICWat 40 °C ambient temperature, in free air from a cold state10 s64 A96 AMinimum switching capacity17 V ; 200 mAMaximum breaking capacity cos φ = 0.45at 400 V 64 A96 AMaximum electrical switching frequencyAC-1300 cycles/hAC-3600 cycles/hDC-1, DC-3, DC-5 600 cycles/h04
2CDC102043C0201 ABB MOTOR PROTECTION AND CONTROL 4/41—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical data—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical dataMain pole – Utilization characteristics according to UL/NEMA/CSAContactor typesAC operatedB6, VB6, VB6AB7, VB7, VB7ADC operatedBC6, VBC6, VBC6ABC7, VBC7, VBC7AStandardsUL 508, CSA C22.2 N°14Maximum operational voltage600 VUL/CSA general use rating12 A / 300 V16 A / 600 VUL/CSA maximum 1-phase motor ratingFull load current120 V AC 5.8 A13.8 A240 V AC 4.9 A10.0 AHorse power rating120 V AC 0.25 hp0.75 hp240 V AC 0.5 hp1.5 hpUL/CSA maximum 3-phase motor ratingFull load current (1)200 / 208 V AC 4.8 / 4.6 A7.8 / 10.6 A220-240 V AC 6.8 A9.6 A440-480 V AC 4.8 A7.6 A550-600 V AC 1.7 A6.1 AHorse power rating (1)200 / 208 V AC 1 hp2 / 3 hp220-240 V AC 2 hp3 hp440-480 V AC 3 hp5 hp550-600 V AC 1 hp5 hpResistive Heating300 V per pole 8 A8 AIncandescent Lamps300 V per pole 6 A6 AFluorescent Lamps300 V per pole 8.4 A8.4 AShort-circuit protection device for contactorswithout thermal overload relay - motor protection excludedFuse rating600 V 40 AFuse type, 600 V600 VClass JMaximum electrical switching frequencyFor resitive loads AC-1300 cycles/hFor motor loads AC-3600 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".General technical dataContactor typesAC operatedB6, VB6, VB6AB7, VB7, VB7ADC operatedBC6, VBC6, VBC6ABC7, VBC7, VBC7ARated insulation voltage Uiacc. to IEC 60947-4-1 690 Vacc. to UL/CSA600 VRated impulse withstand voltage Uimp6 kVAmbient air temperature, close to contactorOperationFitted with thermal overload relay-25 ... +50 °CWithout thermal overload relay-25 ... +55 °CStorage-40 ... +80 °CClimatic withstandAcc. to IEC 60947-1 Annex QMaximum operating altitude (without derating)2000 mMechanical durability107 operating cyclesResistance to shockHalf-sineacc. IEC 60068-2-27 and EN 60068-2-2715 g / 11 msacc. to IEC/EN 60947-1 Annex. QCategory EResistance to vibrationsSinusoidalacc. IEC 60068-2-27 and EN 60068-2-275 g / 3 ... 150 Hzacc. to IEC/EN 60947-1 Annex. QCategory E04
2CDC102043C02014/4 2ABB MOTOR PROTECTION AND CONTROL—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical dataMagnet system characteristics for B6, B7 contactorsContactor typesAC operatedB6, VB6B7, VB7Coil operating limits acc. to IEC 60947-4-1AC supply0.85 ... 1.1 x UcAC control voltageRated control circuit voltage UCSee ordering tablesCoil consumptionAverage pull-in value3.5 VA / 3.5 WAverage holding value3.5 VA / 3.5 WDrop-out voltage0.20 ... 0.75 % of UcMagnet system characteristics for BC6, BC7 contactorsContactor typesDC operatedBC6, VBC6BC7, VBC7Coil operating limits acc. to IEC 60947-4-1DC supply0.85 ... 1.1 x UcAC control voltageRated control circuit voltage UCSee ordering tablesCoil consumption (1)Average pull-in value3.5 VA / 3.5 WAverage holding value3.5 VA / 3.5 WDrop-out voltage in % of UC min0.10 ... 0.75 x UC(1) Interface mini-contactors: see coil consumption on ordering details pagesMounting characteristics and conditions for useContactor typesAC operatedB6, VB6, VB6AB7, VB7, VB7ADC operatedBC6, VBC6, VBC6ABC7, VBC7, VBC7AMounting positionsPos. 1Pos. 2Pos. 4Pos. 1 ± 30°- 30°+ 30°Pos. 5Pos. 6Pos. 3Mounting distancesThe contactors can be assembled side by sideFixingOn rail acc. to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally04
2CDC102043C0201 ABB MOTOR PROTECTION AND CONTROL 4/43—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical dataBuilt-in auxiliary contact according to IECTy pesBuilt-in auxiliary contactsStandardsIEC/EN 60947-1, IEC/EN 60947-4-1Rated operational voltage Ue max690 VRated frequency (without derating)DC or 50 / 60 HzConventional free-air thermal current lth θ ≤ 40 °C6 AIe / Rated operational current AC-15acc. to IEC 60947-5-124 V 50/60 Hz 4 A110-120 V 50/60 Hz 4 A220-230-240 V 50/60 Hz4 A380-400 V 50/60 Hz 3 A440 V 50/60 Hz 3 AIe / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 2.5 A110 V DC 0.7 A220 - 240 V DC 0.4 AShort-circuit protection device6 A, Type gGMinimum switching capacity with failure rate acc. to IEC 60947-5-417 V / 5 mAMaximum electrical switching frequencyAC-15600 cycles/hDC-13600 cycles/hBuilt-in auxiliary contact according to UL/CSATy pesBuilt-in auxiliary contactsMax. operational voltage600 V ACPilot dutyA600AC thermal rated current5 AConnection characteristicsContactor typesAC operatedB6, VB6, VB6AB7, VB7, VB7ADC operatedBC6, VBC6, VBC6ABC7, VBC7, VBC7AMain terminals (1)Screw terminals with cable clampConnection capacityMain conductors (poles)Rigid: solid1 or 2 x 1 ... 4 mm²Flexible without ferrule1 or 2 x 1 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 22 ... 10Stripping length9 mmTightening torques0.8 ... 1.1 Nm / 7 lb.inConnection capacity – auxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid: solid1 or 2 x 1 ... 4 mm²Flexible without ferrule1 or 2 x 1 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 x AWG 22 ... 10Stripping length9 mmTightening torquesCoil terminals0.8 ... 1.1 Nm / 7 lb.inBuilt-in auxiliary terminals0.8 ... 1.1 Nm / 7 lb.inDegree of protectionacc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Main terminalsIP20Coil terminalsIP20Built-in auxiliary terminalsIP20Screw terminals(Delivered in open position, screws of unused terminals must be tightened)All terminalsM3Screwdriver typeFlat Ø 5.5 mm / Pozidriv 1(1) Soldering pin connection acc. to DIN 40801: 0.8 x 1 mm / 0.8 x 2.54 mm Flat pin connection acc. to DIN 46248: 1 x 6.3 mm / 1 x 2.8 mm04
2CDC102043C02014/4 4ABB MOTOR PROTECTION AND CONTROLMain pole – Utilization characteristics according to IECContactor typesAC operatedK6DC operatedKC6StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Uemax690 VRated frequency (without derating)DC or 50 / 60 HzConventional free-air thermal current lth θ ≤ 40 °C6 AIe / Rated operational current AC-15acc. to IEC 60947-5-124 V 50/60 Hz 4 A110-120 V 50/60 Hz 4 A220-230-240 V 50/60 Hz4 A380-400 V 50/60 Hz 3 A440 V 50/60 Hz 3 A480-500 V 50/60 Hz 2 AIe / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 2.5 A110 V DC 0.7 A220-240 V DC 0.4 AShort-circuit protection device for contactors Ue ≤ 500 V AC, fuse type gG6 AMinimum switching capacity17 V / 5 mAMaximum electrical switching frequencyAC-15600 cycles/hDC-13600 cycles/hMain pole – Utilization characteristics according to UL/NEMA/CSAContactor typesAC operatedK6DC operatedKC6StandardsUL 508, CSA C22.2 No14Maximum operational voltage600 V ACPilot dutyA600—K6, KC6 4-pole mini contactor relaysTechnical data04
2CDC102043C0201 ABB MOTOR PROTECTION AND CONTROL 4/45General technical dataContactor relay typesAC operatedK6DC operatedKC6Rated insulation voltage Uiacc. to IEC 60947-5-1690 Vacc. to UL/CSA600 VRated impulse withstand voltage Uimp6 kVElectromagnetic compatibilityAmbient air temperature close to contactor relayOperation in free air-25 ... +55 °CStorage-40 ... +80 °CClimatic withstandAcc. to IEC 60068-2-30Maximum operating altitude (without derating)2000 mMechanical durability107 operating cyclesResistance to shockHalf-sine acc. IEC 60068-2-27 and EN 60068-2-2715 g / 11msacc. to IEC/EN 60947-1 Annex. QCategory EResistance to vibrationsSinusoidalacc. IEC 60068-2-27 and EN 60068-2-275 g / 3 ... 150 Hzacc. to IEC/EN 60947-1 Annex. QCategory EMagnet system characteristics for K6 contactor relaysContactor relay typesAC operatedK6Coil operating limits acc. to IEC 60947-4-1AC supply0.85 ... 1.1 x UCAC control voltageCoil consumptionAverage pull-in value3.5 VA / 3.5 WAverage holding value3.5 VA / 3.5 WDrop-out voltage in % of UC min.Approx. 20 ... 75%Magnet system characteristics for KC6 contactor relaysContactor relay typesDC operatedKC6Coil operating limits acc. to IEC 60947-5-1DC supply0.85 ... 1.1 x UCDC control voltageCoil consumptionAverage pull-in value3.5 VA / 3.5 WAverage holding value3.5 VA / 3.5 WDrop-out voltage in % of UC min.10 ... 75 %—K6, KC6 4-pole mini contactor relaysTechnical data04
2CDC102043C02014/4 6ABB MOTOR PROTECTION AND CONTROLMounting characteristics and conditions for useContactor typesAC operatedK6DC operatedKC6Mounting positionsPos. 1Pos. 2Pos. 4Pos. 1 ± 30°- 30°+ 30°Pos. 5Pos. 6Pos. 3Mounting distancesThe contactors can be assembled side by side.FixingOn rail acc. to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonallyConnecting characteristicsContactor relay typesAC operatedK6DC operatedKC6Main terminals(1)Screw terminals with cable clampConnection capacityMain conductors (poles)Rigid: solid1 or 2 x 1 ... 4 mm²Flexible without ferrule1 or 2 x 1 ... 2.5 mm²Connection apacity acc. to UL/CSA1 or 2 x AWG 22 ... 10Stripping length9 mmTightening torques0.8 ... 1.1 Nm / 7 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529AllIP20Screw terminals(Delivered in open position, screws of unused terminals must be tightened)All terminalsM3Screwdriver typeFlat Ø 5.5 / Pozidriv 1(1) Soldering pin connection acc. to DIN 40801: 0.8 x 1 mm / 0.8 x 2.54 mm Flat pin connection acc. to DIN 46248: 1 x 6.3 mm / 1 x 2.8 mm—K6, KC6 4-pole mini contactor relaysTechnical data04
Summary_accessoriesABB MOTOR PROTECTION AND CONTROL 4/47—Accessories044/48 Accessories for B 3-pole and 4-pole mini contactors, VB 3-pole and 4-pole mini reversing4/50 Accessories for K 4-pole mini contactor relays4/52 Location of the connection terminals and terminal designation4/53 Dimension drawings
Note: The picture is valid for screw terminal contactors only.—Accessories for mini contactorsMS116MS132MO132RV-BC6BEA7B7CAF6RV-BC6RV-BC6RV-BC6E16DUT16B6CA62CDCxxxxBible-mini contacteurs - Rev. A4/4 8 ABB MOTOR PROTECTION AND CONTROL04
2CDC102042C0201 ABB MOTOR PROTECTION AND CONTROL 4/49—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3-pole mini reversing contactorsAccessoriesSuitable forAuxiliarycontactsTy pe Order codePkg qtyWeight(1 pce)kgFront mounted instantaneous auxiliary contact blocks (not allowed for mounting on B6S, B7S, interface contactors) (1) B6-, B7-40-00, BC6-, BC7-40-00VB6, VB7, VBC6, VBC7, VB6A, VB7A VBC6A, VBC7A1 1CAF6-11EGJL1201330R0002100.0202 0CAF6-20EGJL1201330R0006100.0200 2CAF6-02EGJL1201330R0010100.020B6-, B7-30-10, BC6-, BC7-30-10VB6, VB7, VBC6, VBC7, VB6A, VB7A VBC6A, VBC7A1 1CAF6-11MGJL1201330R0003100.0202 0CAF6-20MGJL1201330R0007100.0200 2CAF6-02MGJL1201330R0011100.020B6-, B7-30-01, BC6-, BC7-30-01VB6, VB7, VBC6, VBC7, VB6A, VB7A VBC6A, VBC7A1 1CAF6-11NGJL1201330R0004100.0202 0CAF6-20NGJL1201330R0008100.0200 2CAF6-02NGJL1201330R0012100.020Side mounted instantaneous auxiliary contact block (1) B6-, B7-40-00, BC6-, BC7-40-001 1CA6-11EGJL1201317R0002100.030B6-, B7-30-10, BC6-, BC7-30-101 1CA6-11MGJL1201317R0003100.030B6-, B7-30-01, BC6-, BC7-30-011 1CA6-11NGJL1201317R0004100.030Side mounted instantaneous auxiliary contact block with soldering pins (2)B6-, B7-40-00-P, BC6-,BC7-40-00-P1 1CA6-11E-PGJL1201319R0002100.025B6-, B7-30-10-P, BC6-, BC7-30-10-P1 1CA6-11M-PGJL1201319R0003100.025B6-, B7-30-01-P, BC6-, BC7-30-01-P1 1CA6-11N-PGJL1201319R0004100.025Side mounted instantaneous auxiliary contact block with flat pin connection (2)B6-, B7-40-00-F, BC6-,BC7-40-00-F1 1CA6-11E-FGJL1201318R0002100.025B6-, B7-30-10-F, BC6-, BC7-30-10-F1 1CA6-11M-FGJL1201318R0003100.025B6-, B7-30-01-F, BC6-, BC7-30-01-F1 1CA6-11N-FGJL1201318R0004100.025Soldering socket (Ith = 10 A, AC-3: 500 V / 8 A, 690 V / 3.5 A, UL: 300 V / 8 A)B6, B7, BC6, BC7LB6GJL1201902R0001100.0202-pole aux.contact blocks CALB6-CAGJL1201903R000110 0.010(1) CA6 and CAF6 must not be fitted simultaneously.Suitable forRated control circuit voltage UCConnection typeTy pe Order codePkg qtyWeight(1 pce)V DCkgSurge suppressors for contactor coilsBC6, BC724 ... 60Cable lugRV-BC6/60GHV2501902R0002100.00550 ... 250Cable lugRV-BC6/250GHV2501903R0002100.005Note: Mini contactors for AC operation have an integrated protective circuitConnecting links with manual motor startersTo connect B..VB.. mini contactor to MS116, MS132BEA7/1321SBN080906R1002100.013To connect B..VB.. mini contactors to MS325BEA7/3251SBN080906R1001100.021Connection sets for reversing contactorsVB6, VB7, VBC6, VBC7, VB6A, VB7A, VBC6A, VBC7A, cross-section 1.8 mm² BSM6-30GJL1201908R000110 0.010Parallel connecting linkB6, B7, BC6, BC7LP6GJL1201907R00011000.009Cover cap, transparent fitting to DIN rail design, sealableB6, B7, BC6, BC7LT6-BGJL1201906R0001100.015Plastic label for markingsB6, B7, BC6, BC7BA5-501SBN110000R1000500.020 2CDC211012F0010CAF6-11N 2CDC211008F0010CA6-11E 2CDC211018F0011CA6-11E-P 2CDC211020F0011CA6-11E-F2CDC211007F0010CAF6-11N SST27792RBSM6-30 2CDC231012F0011LT6 - B04
2CDC102042C02014/50ABB MOTOR PROTECTION AND CONTROL—K6, KC6 4-pole mini contactor relaysAccessoriesSuitable forAuxiliarycontactsTy pe Order codePkg qtyWeight(1 pce)kgFront mounted instantaneous auxiliary contact blocks (1) K6, KC61 1CAF6-11KGJL1201330R0001100.0202 0CAF6-20KGJL1201330R0005100.0200 2CAF6-02KGJL1201330R0009100.020Side mounted instantaneous auxiliary contact block (1) K6, KC61 1CA6-11KGJL1201317R0001100.030Side mounted instantaneous auxiliary contact block with soldering pins (2)K6..P, KC6..P1 1CA6-11K-PGJL1201319R0001100.025Side mounted instantaneous auxiliary contact block with flat pin connection (2)K6..F, KC6..F1 1CA6-11K-FGJL1201318R0001100.025Soldering socket ( Ie < 8 A )K6, KC6LB6GJL1201902R0001100.0202-pole auxiliary contact blocks CALB6-CAGJL1201903R000110 0.010(1) CA6 and CAF6 must not be fitted simultaneously.Suitable forRated control circuit voltageUCConnection typeTy pe Order codePkg qtyWeight(1 pce)V DCkgSurge suppressors for contactor coilsKC624 ... 60Cable lugRV-BC6/60GHV2501902R0002100.00550 ... 250Cable lugRV-BC6/250GHV2501903R0002100.005Note: Mini contactors for AC operation have an integrated protective circuitCover cap, transparent fitting to DIN rail design, sealableK6, KC6LT6-BGJL1201906R0001100.0152CDC211019F0011CAF6-11K 2CDC211009F0010CA6-11K 2CDC211011F0010 CA6-11K-P 2CDC211010F0010CA6-11K-F 2CDC211006F0010LT6 - B2CDC211007F0010RV-BC6/25004
2CDC102074C0201 ABB MOTOR PROTECTION AND CONTROL 4/51—B6, B7, BC6, BC7 3- and 4-pole mini contactorsVB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactorsTechnical dataAuxiliary contacts for front mounting and side mounting according to IECTy pesCA6, CAF6StandardsIEC/EN 60947-1, IEC/EN 60947-4-1Rated operational voltage Ue max690 VRated frequency (without derating)DC or 50 / 60 HzConventional free-air thermal current lth θ ≤ 40 °C6 AIe / Rated operational current AC-15acc. to IEC 60947-5-124 V 50/60 Hz4 A110-120 V 50/60 Hz4 A220-230-240 V 50/60 Hz4 A380-400 V 50/60 Hz3 A440 V 50/60 Hz3 AIe / Rated operational current DC-13acc. to IEC 60947-5-124 V DC2.5 A110 V DC0.7 A220 - 240 V DC0.4 AShort-circuit protection device6 A, Type gGMinimum switching capacity with failure rate acc. to IEC 60947-5-417 V / 5 mAMaximum electrical switching frequencyAC-15600 cycles/hDC-13600 cycles/hAuxiliary contacts for front mounting and side mounting according to UL/CSATy pesCA6, CAF6Max. operational voltage600 V ACPilot dutyA600AC thermal rated current5 AConnection characteristicsTy pesCA6, CAF6Auxiliary terminals (1)Screw terminals with cable clampConnection capacity – auxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid: solid1 or 2 x1 ... 4 mm²Flexible without ferrule1 or 2 x1 ... 2.5 mm²Connection capacity acc. to UL/CSA1 or 2 xAWG 22 ... 10Stripping length9 mmTightening torques0.8 ... 1.1 Nm / 7 lb.inDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529Auxiliary terminalsIP20Screw terminals(Delivered in open position, screws of unused terminals must be tightened)All terminalsM3Screwdriver typeFlat Ø 5.5 mm / Pozidriv 1(1) Soldering pin connection acc. to DIN 40801: 0.8 x 1 mm / 0.8 x 2.54 mm Flat pin connection acc. to DIN 46248: 1 x 6.3 mm / 1 x 2.8 mm04
2CDC102074C02014/52 ABB MOTOR PROTECTION AND CONTROLMini contactors1 3 5 7 A12 4 6 8 A2B6(7)-40-00 ...BC6(7)-40-00 ...2CDC212001F00121 3 5 13 A12 4 6 14 A2B6(7)-30-10 ...BC6(7)-30-10 ...2CDC212002F00121 3 5 21 A12 4 6 22 A2B6(7)-30-01 ...BC6(7)-30-01 ...2CDC212003F00121 3 R5 R7 A12 4 R6 R8 A2B6(7)-22-00 ...BC6(7)-22-00 ...2CDC212004F00121 3 5 R7 A12 4 6 R8 A2B6(7)-31-00 ...BC6(7)-31-00 ...2CDC212005F0012Compact reversing contactors1 3 5 21 A12 4 6 22 A2A1 21 1 3 5A2 22 2 4 6VB6(7)-30-01 ...VBC6(7)-30-01 ...2CDC212006F0012A1 13 1 3 5A2 14 2 4 61 3 5 13 A12 4 6 14 A2VB6(7)-30-10 ...VBC6(7)-30-10 ...2CDC212007F0012Mini contactor relays13 23 33 43 A114 24 34 44 A2K6-40E ...KC6-40E ...2CDC212008F001213 33 43 21 A114 34 44 22 A2K6-31Z ...KC6-31Z ...K6S-31Z ...2CDC212009F001213 43 21 31 A114 44 22 32 A2K6-22Z ...KC6-22Z ...K6S-22Z ...2CDC212010F0012Auxiliary switchesCA6...CAF...1 3 5 72 4 6 813 2114 22CA6-11E CA6-11E-FCA6-11E-PB(C)6(7)-40-00B(C)6(7)-40-00-FB(C)6(7)-40-00-P1 3 5 72 4 6 8CAF 61321142213231424112112221 2 31 = CAF6-11E 2 = CAF6-20E3 = CAF6-02EB(C)6(7)-40-001 3 5 132 4 6 1433 2134 22CA6-11M CA6-11M-FCA6-11M-PB(C)6(7)-30-10B(C)6(7)-30-10-FB(C)6(7)-30-10-P1 3 5 132 4 6 14CAF 63321342223332434213122321 2 31 = CAF6-11M 2 = CAF6-20M3 = CAF6-02MB(C)6(7)-30-101 3 5 212 4 6 2213 3114 32CA6-11N CA6-11N-FCA6-11N-PB(C)6(7)-30-01B(C)6(7)-30-01-FB(C)6(7)-30-01-P1 3 5 212 4 6 22CAF 61331143213331434113112321 2 31 = CAF6-11N 2 = CAF6-20N3 = CAF6-02N B(C)6(7)-30-0153 6154 6240 E31 Z22 ZCA6-11K CA6-11K-FCA6-11K-PK(C)6 .....K(C)6 ....-FK(C)6 ....-P53635464536154625161526240 E31 Z22 Z1 2 31 = CAF6-11K2 = CAF6-20K3 = CAF6-02K K(C)6 .....—Mini contactorsLocation of the connection terminals and terminal designation04
2CDC102074C0201 ABB MOTOR PROTECTION AND CONTROL 4/53Front mounted auxiliary contact blocks, with screw terminals38.4 44 47.5 9.6 26.6 29 1.51"1.73"1.87"0.38"1.05"1.14"4.5 29 43.7 73.3 42.2 50 57.5 35 40 45 4.5 47.5 0.18"1.14"1.72"2.89"1.66"1.97"2.26"1.38"1.57"1.77"0.18"1.87"CAF6Mini contactors or contactor relays + CAF642.2 1.66"45.2 1.78"57.5 2.26"96.2 3.79"10.1 0.4"10 0.39"43.7 1.72"59.4 2.34"73.3 2.89"4.5 0.18"29 1.14"Mini reversing contactors + CAF6 (max. 2 contact blocks) Side mounted auxiliary contact blocks, with screw terminals 42.2 48.4 20.3 43.4 46.4 1.66"1.91"0.8"1.71"1.83"67.8 2.67"43.7 1.72"46.7 1.84"42.2 1.66"57.5 2.26"4.5 0.18"CA6-11E, CA6-11M, CA6-11NMini contactors or contactor relays + CA6-11E, CA6-11M, CA6-11N—Mini contactors and contactor relaysDimension drawings with accessoriesMain dimensions mm, inches04
2CDC102074C02014/54 ABB MOTOR PROTECTION AND CONTROLSide mounted auxiliary contact blocks, with soldering pins20.3 44.4 47.4 4.3 42.2 48.4 0.8"1.75"1.87"0.17"1.66"1.91"1 42.2 67.8 44.7 47.7 4.3 0.04"1.66"2.67"1.76"1.88"0.17"CA6-11E-P, CA6-11M-P, CA6-11N-PMini contactors or contactor relays + CA6-11E-P, CA6-11M-P, CA6-11N-PSide mounted auxiliary contact blocks, with flat pin connection43.4 46.4 42.2 48.4 20.3 1.71"1.83"1.66"1.91"0.8"43.7 46.7 4.5 67.8 42.2 57.5 1.72"1.84"0.18"2.67"1.66"2.26"CA6-11E-F, CA6-11M-F, CA6-11N-FMini contactors or contactor relays + CA6-11E-F, CA6-11M-F, CA6-11N-F Front mounted cover cap for DIN rail panel installation45 63 52.5 55 25.6 4.5 33.5 43.5 58 61 1.77"2.48"2.07"2.17"0.18"1.01"1.32"1.71"2.28"2.4"Mini contactors or contactor relays + LT6-B cover cap—Mini contactors and contactor relaysDimension drawings with accessoriesMain dimensions mm, inches04
2CDC102074C0201 ABB MOTOR PROTECTION AND CONTROL 4/55Drilling plans for wall mounting35 1.38"40 1.57"45 1.77"50 1.97"Ø 4.5 Ø 0.18"50 1.97"90 3.54"Ø 4.5 Ø 0.18"Mini contactors or contactor relays with screw terminals and flat pin connection Mini reversing contactors with screw terminals and flat pin connectionDrilling plans for PCBA25.4 1"10.16 0.4"20.32 0.8"30.48 1.2"38.08 1.5"Ø 1.5 Ø 0.06"10.16 25.4 58.43 Ø1.5 5 x 10.16 = 50.83 0.4"1"2.3"Ø0.06"5 x 0.4" = 2"Mini contactors or contactor relays with soldering pinsMini contactors or contactor relays with soldering pins + CA6-11E-P, CA6-11M-P, CA6-11N-P10.18 0.4"3 x 10.6 = 30.48 3 x 10.6 = 30.48 3 x 0.4" = 1.2"3 x 0.4" = 1.2"25.4 1"86.34 3.4"Ø 1.5 Ø 0.06"10.16 0.4"Mini reversing contactors with soldering pins—Mini contactors and contactor relaysDimension drawings with accessoriesMain dimensions mm, inches04
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AS09-30-10-20 www.abb.com/productdetails/1SBL101001R2010or
ABB MOTOR PROTECTION AND CONTROL 5/1 3-pole contactors5/3 Overview5/8 AS09 ... AS16 AC operated5/9 ASL09 ... ASL16 DC operated5/10 AS09 ... AS16 AC operated - 2-stack5/11 ASL09 ... ASL16 DC operated - 2-stack5/12 Main accessories5/14 Technical data5/20 Electrical durability5/22 Terminal marking and positioning5/24 Dimensions Contactor relays5/28 Overview5/30 NS AC operated5/31 NSL DC operated5/32 Main accessories5/34 Technical data5/38 Terminal marking and positioning5/40 Dimensions Accessories5/42 Auxiliary contact blocks5/45 Electronic timers5/48 Surge suppressors5/50 Mechanical interlock unit and other accessories5/51 Connection accessories for starting solutions 5/52 Voltage code table—AS 3-pole contactors and NS 3-pole contactor relayswith screw terminals05
5/2ABB MOTOR PROTECTION AND CONTROL05
ABB MOTOR PROTECTION AND CONTROL 5/31SBC100208S0201—AS contactorsEfficient and space savingThe compact AS contactor range allows you to optimize equipment design and is a reliable, time and cost saving solution.Speed up your projectsSimpler by designAS contactors come in one single size and are de-signed to make life easy for engineering, handling and wiring purposes. These products follow a simple marking pattern, which enables a quick identification of their individual features.Easy to installEasy to useMake engineering a simple process with AS con-tactors. Every product is delivered with opened terminals, located directly on the front for easy access. Every terminal is screwdriver guided. Spring terminal versions are also available for a time-saving and reliable connection alternative.Space savingSpace optimizationThe addition of accessories keeps the panel smart and compact, while providing additional features. Interlocking kits and surge suppression are clipped into the housing without adding width to the small frame of the contactor.05
—Compact and efficientOptimize your equipment dimensions!Side clip-on surge suppressorsThis add-on snaps and connects to the side of the housing and does not add width to the frame. The coil terminals remain accessible this way.ACDCorW 45 x H 68 x D 72.5 mm Easy to engineer with just one sizeFor motor starting solutions up to 7.5 kW at 400 V and 3 hp at 440 V, contactors are in one frame size for both AC and DC coils.Spring Spring terminalScrew Screw terminalOn top of that, they are available with screw or spring terminals.90 mmCompact reversing contactorsWith their low consumption coil of only 3 W, AS contactors can be controlled directly by most PLC's. For 24 V control circuits, this is only 125 mA.5/4ABB MOTOR PROTECTION AND CONTROL1SBC100209S020105
—Easy to useSpace-saving and intuitiveTwo types of terminals, for even more choicesAs an alternative to the conventional screw terminals, spring terminals are often used in applications with vibrations. Both types are able to accommodate two cables. This way, AS offers the right type of terminal depending on the installation.Make your control circuits reliableBuilt-in and add-on auxiliary contacts offer high reliability for low signals and meet the requirements for mechanically linked and mirror contacts according to IEC standards.Direct control by PLCWith their low consumption coil of only 3 W, AS contactors can be controlled directly by most PLC's. For 24 V control circuits, this is only 125 mA.Choose reliable and time-saving solutionsAS contactors can easily be connected to manual motor starters or overload relays. The connecting accessories prevent mistakes and save time when assembling starter combinations.A1+A2- ABB MOTOR PROTECTION AND CONTROL 5/51SBC100209S020105
1SBC101292S02015/6ABB MOTOR PROTECTION AND CONTROLMain accessories for starting solutionsDirect-on-line starterReversing starterStar-delta starterMain accessories for contactors—3-pole contactorsMain accessoriesAS09 ... AS16 3-pole contactorsRV5, RT5 or RC5-1Surge suppressorCA-31-pole auxiliary contact blockT16 Thermal overload relayT16 Thermal overload relayAS ASL ContactorsASASLContactorsBER16C-3 Connection setT16 Thermal overload relayVM3 Mechanical interlock unitT16 Thermal overload relayAS ASL ContactorsBEY16C-3 Connection setTimer05
1SBC101292S0201ABB MOTOR PROTECTION AND CONTROL 5/7—3-pole contactors Screw terminalsAC control voltageAS09AS12AS16DC control voltageASL09ASL12ASL16Switching of 3-phase cage motors3M33IECAC-3Rated operational power400 V4 kW5.5 kW7.5 kWRated operational currentθ ≤ 60 °C400 V9 A12 A15.5 Aθ ≤ 60 °C415 V9 A12 A15.5 Aθ ≤ 60 °C690 V5 A7 A9 AUL / CSA3-phase motor rating440-480 V5 hp7.5 hp10 hpNEMA size00 000Protection of 3-phase motorsThermal overload relaysT16...Switching of resistive circuitsR3R3IECAC-1Rated operational currentθ ≤ 40 °C690 V22 A24 A24 Aθ ≤ 60 °C690 V18 A20 A20 Aθ ≤ 70 °C690 V15 A16 A16 AWith conductor cross-sectional area2.5 mm²2.5 mm²2.5 mm²UL / CSAGeneral use rating600 V AC20 A20 A20 AWith conductor cross-sectional areaAWG 12AWG 12AWG 12Main accessoriesAuxiliarycontact blocksFront mounting1-pole CA3-10 or CA3-01InterlocksMechanicalVM3Surge suppressorsSide-mounted (without additional width)RV5(Varistor) AC / DCRC5-1 (Capacitor) ACRT5(Transil diode) DCConnection setsReversing startersStar-delta startersBER16C-3 BEY16C-3Connecting linkWith manual motor starterBEA16-30.10...0.130.23...0.310.55...0.741.30...1.703.10...4.207.60...10.00.13...0.170.31...0.410.74...1.001.70...2.304.20...5.7010.0...13.00.17...0.230.41...0.551.00...1.302.30...3.105.70...7.6013.0...16.005
1SBC101301S0201 - Rev. A—AS09 ... AS16 3-pole contactors4 to 7.5 kW AC operatedAS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:•3 main poles and 1 built-in auxiliary contact •control circuit: AC operated•add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc (1)AuxiliarycontactsfittedTy pe Order codeWeight Pkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower 400 VAC-3currentθ ≤ 40 °C AC-1kWAhpAV 50 HzV 60 Hzkg42252024241 0AS09-30-10-201SBL101001R20100.2200 1AS09-30-01-201SBL101001R20010.2202302301 0AS09-30-10-261SBL101001R26100.2200 1AS09-30-01-261SBL101001R26010.2205.5247.52024241 0AS12-30-10-201SBL111001R20100.2200 1AS12-30-01-201SBL111001R20010.2202302301 0AS12-30-10-261SBL111001R26100.2200 1AS12-30-01-261SBL111001R26010.2207.524102024241 0AS16-30-10-201SBL121001R20100.2200 1AS16-30-01-201SBL121001R20010.2202302301 0AS16-30-10-261SBL121001R26100.2200 1AS16-30-01-261SBL121001R26010.220Note: for multiple packaging, please contact your ABB local sales organization. (1) Other control voltages see voltage code table.72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"50 1.97"60 2.36"35 1.38"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"AS09, AS12, AS161SBC101007F0014AS09-30-10Main dimensions mm, inches5/8ABB MOTOR PROTECTION AND CONTROL05
1SBC101302S0201 - Rev. A1SBC101010F0014ASL09-30-10ASL09 ... ASL16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with:• 3 main poles and 1 built-in auxiliary contact • control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core mag-net. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)• add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV DCkg422520241 0ASL09-30-10-811SBL103001R81100.2800 1ASL09-30-01-811SBL103001R81010.2805.5247.520241 0ASL12-30-10-811SBL113001R81100.2800 1ASL12-30-01-811SBL113001R81010.2807.5241020241 0ASL16-30-10-811SBL123001R81100.2800 1ASL16-30-01-811SBL123001R81010.280Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"ASL09, ASL12, ASL16—ASL09 ... ASL16 3-pole contactors4 to 7.5 kWDC operatedMain dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/905
1SBC101303S0201 - Rev. A—AS09 ... AS16 2-stack 3-pole contactors4 to 7.5 kWAC operated AS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:•1st stack with 3 main poles and 1 N.O. built-in auxiliary contact•2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block. The auxiliary contact el-ements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts•control circuit: AC operated•a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV 50 HzV 60 Hzkg42252024243 2AS09-30-32-201SBL101001R20320.2602302303 2AS09-30-32-261SBL101001R26320.2605.5247.52024243 2AS12-30-32-201SBL111001R20320.2602302303 2AS12-30-32-261SBL111001R26320.2607.524102024243 2AS16-30-32-201SBL121001R20320.2602302303 2AS16-30-32-261SBL121001R26320.260Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.1SBC101332F0014AS09-30-3245 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"AS09, AS12, AS16Main dimensions mm, inches5/10ABB MOTOR PROTECTION AND CONTROL05
1SBC101453S0201 - Rev. A1SBC101334F0014ASL09-30-32ASL09 ... ASL16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:• 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact• 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block. The auxiliary contact el-ements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts• control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core mag-net. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected) • a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightPkg(1 pce)Rated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 VAC-3currentθ ≤ 40 °CAC-1kWAhpAV DCkg422520243 2ASL09-30-32-811SBL103001R81320.3205.5247.520243 2ASL12-30-32-81 1SBL113001R81320.3207.5241020243 2ASL16-30-32-811SBL123001R81320.320Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"ASL09, ASL12, ASL16—ASL09 ... ASL16 2-stack 3-pole contactors4 to 7.5 kWDC operatedMain dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/1105
1SBC101297S02015/12ABB MOTOR PROTECTION AND CONTROLMS116Manual motor starterBEA16-3Connecting linkASASLContactorsASASLContactorsBER16C-3 Connection setT16 Thermal overload relayVM3 Mechanical interlock unitT16 Thermal overload relayAS ASL ContactorsBEY16C-3 Connection setTimer—AS09 ... AS16 and ASL09 ... ASL16 3-pole contactorsMain accessoriesMain accessory fitting detailsMany configurations of accessories are possible depending on whether these are front-mounted or side-mounted.ContactortypesMainpolesBuilt-inauxiliarycontactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timerMechanical interlock unit (between 2 contactors)1-pole CA3TEF3VM3Surge suppressorsAS09 ... AS163 01 02 max.or1+1+RV5orRC5-13 00 1AS09 ... AS163 03 2––1+RV5orRC5-1ASL09 ... ASL163 01 02 max.or1+1+RV5orRT5 3 00 1ASL09 ... ASL163 03 2––1+RV5orRT5 Overload relays fitting details (1)Contactor typesThermal overload relaysAS09 ... AS16T16 (0.10...16 A)ASL09 ... ASL16The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.(1) Direct mounting - No kit required.Contactor and main accessories (other accessories available)TEF3CA3RV5, RC5-1 or RT505
1SBC101297S0201 ABB MOTOR PROTECTION AND CONTROL 5/13—AS09 ... AS16 and ASL09 ... ASL16 3-pole contactorsMain accessoriesFront-mounted instantaneous auxiliary contact blocksFor contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgAS09 ... AS161 0CA3-101SBN011010T1010100.011ASL09 ... ASL160 1CA3-011SBN011010T1001100.011Front-mounted electronic timer For contactorsRated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)V kgON-delayAS09 ... AS16, ASL09 ... ASL1624...240 V AC/DCTEF3-ON1SBN021012R100010.065OFF-delayAS09 ... AS16, ASL09 ... ASL1624...240 V AC/DCTEF3-OFF1SBN021014R100010.065Mechanical interlock unitFor contactorsTy pe Order codePkg qtyWeight(1 pce)kgAS09 ... AS16, ASL09 ... ASL16VM31SBN031005T1000100.002Surge suppressorsFor contactors Rated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)kgVACDCAS09 ... AS16, ASL09 ... ASL1624...50RV5/501SBN050010R100020.01550...133RV5/1331SBN050010R100120.015110...250RV5/2501SBN050010R100220.015250...440RV5/4401SBN050010R100320.015AS09 ... AS1624...50–RC5-1/501SBN050100R100020.01250...133–RC5-1/1331SBN050100R100120.012110...250–RC5-1/2501SBN050100R100220.012250...440–RC5-1/4401SBN050100R100320.012ASL09 ... ASL1612...32–RT5/321SBN050020R100020.01525...65–RT5/651SBN050020R100120.01550...90–RT5/901SBN050020R100220.01577...150–RT5/1501SBN050020R100320.015150...264–RT5/2641SBN050020R100420.015Connecting links with manual motor startersFor contactorsManual motor starterType Order codePkg qtyWeight(1 pce)kgAS09 ... AS16MS116-0.16 ... MS116-16 MS132-0.16 ... MS132-16BEA16-31SBN081006T1000100.019ASL09 ... ASL16Connection sets for reversing contactorsFor contactorsMechanical interlock unitType Order codePkg qtyWeight(1 pce)kgAS09 ... AS16, ASL09 ... ASL16with or without VM3BER16C-31SBN081012R100010.035Note: BER16C-3 connection set includes two BB3 fixing clips, and an electrical interlocking when fitted on contactors with built-in N.C. auxiliary contacts. BER16C-3 can be used with or without VM3 mechanical interlock unit.Connection sets for star-delta startingFor contactorsMech. interlock unit between Star & Delta contactorsTy pe Order codePkg qtyWeight(1 pce)kgAS09 ... AS12, ASL09 ... ASL12with or without VM3BEY16C-31SBN081018R200010.041Note: BEY16C-3 connection set includes two BB3 fixing clips, and an electrical interlocking when fitted on Star and Delta contactors with built-in N.C. auxiliary contacts. BEY16C-3 can be used with or without VM3 mechanical interlock unit.1SBC101036F0014CA3-101SBC101337F0014TEF3-ON1SBC101069F0014VM31SBC574001F0301RV51SBC101034F0014BEA16-31SBC101070F0014BEY16C-31SBC101071F0014BER16C-305
1SBC101489S02015/14ABB MOTOR PROTECTION AND CONTROLMain pole - Utilization characteristics according to IECContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C22 A25 A25 AWith conductor cross-sectional area2.5 mm²4 mm²4 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 22 A24 A24 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 18 A20 A20 Aθ ≤ 70 °C 15 A16 A16 AWith conductor cross-sectional area2.5 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V 9 A12 A15.7 A400 V 9 A12 A15.5 A415 V 9 A12 A15.5 A440 V 8 A11 A13.6 A500 V 8 A11 A12.5 A690 V 5 A7 A9 ARated operational power AC-3 (1)M3220-230-240 V 2.2 kW3 kW4 kW400 V 4 kW5.5 kW7.5 kW1500 r.p.m. 50 Hz415 V 4 kW5.5 kW7.5 kW1800 r.p.m. 60 Hz440 V 4 kW5.5 kW7.5 kW3-phase motors500 V 4 kW5.5 kW7.5 kW690 V 4 kW5.5 kW7.5 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)Ie / Rated operational current AC-8a12 A16 A22 ARated operational power AC-8a5.5 kW7.5 kW11 kWShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse25 ARated short-time withstand current Icw1 s 230 A250 A250 Aat 40 °C ambient temperature,10 s 100 A124 A124 Ain free air from a cold state30 s 65 A75 A75 A1 min 50 A55 A55 A15 min 22 A24 A24 AMaximum breaking capacitycos φ = 0.45at 440 V 155 Aat 690 V 90 APower dissipation per poleIe / AC-1 1 W1.2 W1.2 WIe / AC-3 0.16 W0.3 W0.5 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-4300 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".—AS09 ... AS16 andASL09 ... ASL16 3-pole contactorsTechnical data05
1SBC101489S0201 ABB MOTOR PROTECTION AND CONTROL 5/15Main pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16StandardsUL 508, CSA C22.2 N°14Max. operational voltage690 VNEMA size00000NEMA continuous amp ratingThermal current9 A9 A18 ANEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 1/3 hp1/3 hp1 hp230 V AC 1 hp1 hp2 hpNEMA maximum horse power ratings 3-phase, 60 Hz200 V AC 1 1/2 hp1 1/2 hp3 hp230 V AC 1 1/2 hp1 1/2 hp3 hp460 V AC 2 hp2 hp5 hp575 V AC 2 hp2 hp5 hpUL / CSA general use rating600 V AC20 A20 A20 AWith conductor cross-sectional areaAWG 12AWG 12AWG 12UL / CSA maximum 1-phase motor ratingFull load current120 V AC 7.2 A9.8 A13.8 A240 V AC 8 A10 A12 AHorse power rating120 V AC 1/3 hp1/2 hp3/4 hp240 V AC 1 hp1-1/2 hp2 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 7.8 A7.8 A11 A220-240 V AC 6.8 A9.6 A15.2 A440-480 V AC 7.6 A11 A14 A550-600 V AC 9 A11 A11 AHorse power rating (1)200-208 V AC 2 hp2 hp3 hp220-240 V AC 2 hp3 hp5 hp440-480 V AC 5 hp7-1/2 hp10 hp550-600 V AC 7-1/2 hp10 hp10 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedFuse rating40 A50 A60 AFuse type, 600 VJ Max. electrical switching frequencyFor general use 600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".General technical dataContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16Rated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVAmbient air temperature close to contactorOperationFitted with thermal overload relay-25...+60 °CWithout thermal overload relay-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hShock withstand1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionacc. to IEC 60068-2-27 and EN 60068-2-27Shock directionAS contactors - AC operatedASL contactors - DC operatedMounting position 1B2AAB1C2C1A20 g20 g closed position / 10 g open positionB1 10 g closed position / 5 g open position15 g closed position / 5 g open positionB2 15 g10 gC1 20 g closed position / 9 g open position15 g closed position / 8 g open positionC2 20 g closed position / 14 g open position14 g closed position / 8 g open positionVibration withstand acc. to IEC 60068-2-65...300 Hz / 3 g closed position / 2 g open position—AS09 ... AS16 and ASL09 ... ASL16 3-pole contactorsTechnical data05
1SBC101489S02015/16ABB MOTOR PROTECTION AND CONTROLMagnet system characteristics for AS09 ... AS16 contactorsContactor typesAC operatedAS09AS12AS16Coil operating limits AC supplyacc. to IEC 60947-4-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)AC control voltageRated control circuit voltage Ucat 50 Hz 24...415 Vat 60 Hz 24...415 VCoil consumptionAverage pull-in value50 Hz 33 VA60 Hz 33 VA50/60 Hz 33 VAAverage holding value50 Hz 6.5 VA / 1.5 W60 Hz 5 VA / 1.2 W50/60 Hz 6.5 VA / 1.5 WDrop-out voltageApprox. 30...50 % of UcOperating timeBetween coil energization and:N.O. contact closing9...24 msN.C. contact opening6...18 msBetween coil de-energization and:N.O. contact opening (1) 5...19 msN.C. contact closing (1) 7...22 ms(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3Magnet system characteristics for ASL09 ... ASL16 contactorsContactor typesDC operatedASL09ASL12ASL16Coil operating limits DC supplyacc. to IEC 60947-4-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)DC control voltageRated control circuit voltage Uc12...240 V DCCoil consumptionAverage pull-in value3 WAverage holding value3 WDrop-out voltageApprox. 10...40 % of UcCoil time constantOpenL/R12 msClosedL/R40 msOperating timeBetween coil energization and:N.O. contact closing36...59 msN.C. contact opening31...53 msBetween coil de-energization and:N.O. contact opening (1) 13...17 msN.C. contact closing (1) 15...20 ms(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2Mounting characteristics and conditions for useContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16Mounting positionsPos. 1 ± 30°+30°-30°Pos. 3Pos. 2Pos. 1Pos. 4Pos. 5Mounting distancesThe contactors can be assembled side by side.FixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally—AS09 ... AS16 andASL09 ... ASL16 3-pole contactorsTechnical data05
1SBC101489S0201 ABB MOTOR PROTECTION AND CONTROL 5/17Connecting characteristicsContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16Main terminalsScrew terminals with cable clampConnection capacity (min. ... max.)Main conductors (poles)Rigid solid1 x 0.75...4 mm²2 x 0.75...4 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlBars or lugsL ≤ 7.7 mml >3.2 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...12Stripping length9 mmTightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlLugsL ≤ 7.7 mml >3.2 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping lengthTightening torqueCoil terminalsRecommended1.00 Nm / 9 lb.inMax.1.20 NmBuilt-in auxiliary terminalsRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529All terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3Screwdriver typeFlat Ø 5.5 / Pozidriv 2—AS09 ... AS16 andASL09 ... ASL16 3-pole contactorsTechnical data05
1SBC101489S02015/18ABB MOTOR PROTECTION AND CONTROLBuilt-in auxiliary contacts according to IECContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ith - θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Afor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts1.5 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Mirror contactsBuilt-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA3 aux. contact blocks) are mirror contacts.acc. to annex F of IEC 60947-4-1Built-in auxiliary contacts according to UL / CSAContactor typesAC operatedAS09AS12AS16DC operatedASL09ASL12ASL16Max. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—AS09 ... AS16 andASL09 ... ASL16 3-pole contactorsTechnical data05
—Notes05 ABB MOTOR PROTECTION AND CONTROL 5/19
1SBC101931S02015/20ABB MOTOR PROTECTION AND CONTROL—AS09 ... AS16 and ASL09 ... ASL16 3-pole contactorsElectrical durabilityElectrical durability for AC-1 utilization category - Ue ≤ 690 VNote: AC-1 maximum current is selected according to ambient temperature. Please see technical data.Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load. Maximum electrical switching frequency: 600 cycles / hour.135791357913579135791357910.10.20.30.53410235302020.69AS09ASL09, AS12, ASL12,AS16, ASL16AS12, ASL12,AS16, ASL16ASL09Millions of operating cyclesBreaking current Ic (A)Example:Breaking current = 9 A.On the opposite curve at intersection "" 9 A the corresponding value for the electrical durability is approximately 0.6 mil-lions operating cycles.05
1SBC101930S0201 ABB MOTOR PROTECTION AND CONTROL 5/21—AS09 ... AS16 and ASL09 ... ASL16 3-pole contactorsElectrical durabilityElectrical durability for AC-3 utilization category - Ue ≤ 440 V - Ambient temperature ≤ 60 °CSwitching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated op-erational current Ie (Ie = motor full load current). Maximum electrical switching frequency: 1200 cycles / hour.13579135791010.20.30.5325102352013579AS12, ASL12AS16, ASL16AS09, ASL0934Millions of operating cyclesBreaking current Ic (A)Example:Breaking current = 4 A.On the opposite curve at intersection "" 4 A the corresponding value for the electrical durability is approximately 3 millions operating cycles.05
1SBC101404S02015/22ABB MOTOR PROTECTION AND CONTROL21NCNC225L33L2A1A26T34T21L12T113NONO1433NONO3421NCNC225L33L2A1A26T34T21L12T113NONO14Combination 11Combination 21Combination 11AS09 ... AS16-30-10=A1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L313NO2T14T26T3NO14=+-1-2NC2-2-2122NCCA3-01 +Combination 21=AS09 ... AS16-30-10A1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L313NO2T14T26T3NO14=++-1-2NC-3-4NO2-2-3-3-2122NC3334NOCA3-01 CA3-10 ++—AS09 ... AS16 3-pole contactorsTerminal marking and positioningA1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L321NC2T14T26T3NC22AS09 ... AS16-30-10AS09 ... AS16-30-32AS09 ... AS16-30-01A1A21L13L2 5L31353NO2T14T2 6T3NONO43NO31NC21NC54NO44NO32NC22NCNONONCNC145L33L2A1A26T34T21L12T113NONO145L33L2A1A26T34T21L12T121NCNC22AS09 ... AS16-30-01AS09 ... AS16-30-105L33L2A1A26T34T21L12T153NONO5443NONO4431NCNC3221NCNC2213NONO14AS09 ... AS16-30-32AS contactors - AC operatedStandard devices without addition of auxiliary contactsOther possible contact combinations with auxiliary contact blocks added by the user-1NC-2-3NO-4-1-2NC-3-4NOCA3-10CA3-01 CA3 1-pole auxiliary contact blocksTEF355NC67NONC56NO6855566768NCNOTEF3 front-mounted electronic timer05
1SBC101404S0201ABB MOTOR PROTECTION AND CONTROL 5/23—ASL09 ... ASL16 3-pole contactorsTerminal marking and positioningASL09 ... ASL16-30-10ASL09 ... ASL16-30-32ASL09 ... ASL16-30-01A1+A2-1L13L2 5L31353NO2T14T2 6T3NONO43NO31NC21NC54NO44NO32NC22NCNONONCNC14A1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L321NC2T14T26T3NC22ASL09 ... ASL16-30-105L33L2A1+A2-6T34T21L12T153NONO5443NONO4431NCNC3221NCNC2213NONO14ASL09 ... ASL16-30-325L33L2A1+A2-6T34T21L12T113NONO14ASL09 ... ASL16-30-015L33L2A1+A2-6T34T21L12T121NCNC22ASL contactors - DC operated (the polarity A1+, A2- must be respected)Standard devices without addition of auxiliary contactsCombination 2121NCNC225L33L2A1+A2-6T34T21L12T113NONO1433NONO3421NCNC225L33L2A1+A2-6T34T21L12T113NONO14Combination 11Combination 11ASL09 ... ASL16-30-10=CA3-01 +A1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L313NO2T14T26T3NO14=+-1-2NC2-2-2122NCCombination 21=ASL09 ... ASL16-30-10CA3-01 CA3-10++A1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L313NO2T14T26T3NO14=++-1-2NC-3-4NO2-2-3-3-2122NC3334NOOther possible contact combinations with auxiliary contact blocks added by the user-1NC-2-3NO-4-1-2NC-3-4NOCA3-10CA3-01 TEF355NC67NONC56NO6855566768NCNOCA3 1-pole auxiliary contact blocksTEF3 front-mounted electronic timer05
1SBC101405S02015/24ABB MOTOR PROTECTION AND CONTROL—AS09 ... AS16 3-pole contactorsDimensions100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"ø 4.2 0.17"2 xM4 8-32 UNC100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"ø 4.2 0.17"2 xM4 8-32 UNCAS09, AS12, AS16+ CA3 front-mounted 1-pole auxiliary contact block72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"50 1.97"60 2.36"35 1.38"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"AS09, AS12, AS16AS09, AS12, AS16+ TEF3 electronic timerAS09 ... 16-30-32100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"1.1 0.05"35 mm EN/IEC 6071544.2 1.74"128.1 5.04"ø 4.2 0.17"2 xM4 8-32 UNC44.4 1.75"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inches05
1SBC101405S0201ABB MOTOR PROTECTION AND CONTROL 5/25—AS09 ... AS16 3-pole contactorsDimensions50 1.97"60 2.36"125 4.92"ø 4.2 0.17"4 xM4 8-32 UNC5.5 0.22"7 0.28"35 mm EN/IEC 6071572.5 2.85"68 2.68"78.5 3.09"135 5.31"10 0.39"AS09, AS12, AS16+ BEY16C-3 connection set for star-delta starter including four BB3 fixing clips50 1.97"60 2.36"80 3.15"ø 4.2 0.17"2 xM4 8-32 UNC5.5 0.22"7 0.28"35 mm EN/IEC 6071572.5 2.85"68 2.68"78.5 3.09"90 3.54"10 0.39"AS09, AS12, AS16+ BER16C-3 connection set for reversing starter including two BB3 fixing clips68 2.68"90 3.54"50 1.97"60 2.36"80 3.15"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"4 xM4 8-32 UNC10 0.39"AS09, AS12, AS16+ VM3 mechanical interlock unit including two BB3 fixing clipsMain dimensions mm, inches05
1SBC101406S02015/26ABB MOTOR PROTECTION AND CONTROL—ASL09 ... ASL16 3-pole contactorsDimensions100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCASL09, ASL12, ASL16ASL09, ASL12, ASL16+ CA3 front-mounted 1-pole auxiliary contact blockASL09, ASL12, ASL16+ TEF3 electronic timerASL09 ... 16-30-32100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715128.1 5.04"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNC44.4 1.75"1.1 0.05"100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNC60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inches05
1SBC101406S0201ABB MOTOR PROTECTION AND CONTROL 5/27—ASL09 ... ASL16 3-pole contactorsDimensions78.5 3.09"135 5.31"60 2.36"125 4.92"ø 4.2 0.17"4 xM4 8-32 UNC5.5 0.22"7 0.28"35 mm EN/IEC 6071572.5 2.85"68 2.68"10 0.39"ASL09, ASL12, ASL16+ BEY16C-3 connection set for star-delta starter including four BB3 fixing clips5.5 0.22"7 0.28"35 mm EN/IEC 6071572.5 2.85"68 2.68"78.5 3.09"90 3.54"80 3.15"60 2.36"ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"ASL09, ASL12, ASL16+ BER16C-3 connection set for reversing starter including two BB3 fixing clips68 2.68"90 3.54"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071510 0.39"80 3.15"60 2.36"ø 4.2 0.17"4 xM4 8-32 UNCASL09, ASL12, ASL16+ VM3 mechanical interlock unit including two BB3 fixing clipsMain dimensions mm, inches05
1SBC101409S02015/28ABB MOTOR PROTECTION AND CONTROL—Contactor relaysMain accessoriesNS, NSL Contactor relays4-pole contactor relays8-pole contactor relaysNSNSLContactor relaysRV5, RT5 or RC5-1Surge suppressorRV5, RT5 or RC5-1Surge suppressorNSNSLContactor relaysCA-31-pole auxiliary contact block05
1SBC101409S0201 ABB MOTOR PROTECTION AND CONTROL 5/29—Contactor relays Screw terminalsAC control voltageNS22ENS31ENS40EDC control voltageNSL22ENSL31ENSL40E2 N.O. + 2 N.C.3 N.O. + 1 N.C.4 N.O.AC control voltageNS44ENS53ENS62ENS71ENS80EDC control voltageNSL44ENSL53ENSL62ENSL71ENSL80E4 N.O. + 4 N.C.5 N.O. + 3 N.C.6 N.O. + 2 N.C.7 N.O. + 1 N.C.8 N.O.Control circuit switchingIECRated operational currentAC-15240 V 4 A400 V 3 A690 V 2 ADC-1324 V 6 A / 144 W250 V 0.27 A / 68 WUL / CSAPilot DutyA600, Q300Main accessoriesAuxiliarycontact blocksFront mounting1-pole CA3-10 or CA3-01Surge suppressorsSide-mounted (without additional width)RV5 (Varistor) AC / DC RC5-1 (Capacitor) AC RT5 (Transil diode) DCNSNSNSLNSL05
1SBC101475S0201 - Rev. A1SBC101012F0014NS22ENS contactor relays are used for switching auxiliary and control circuits.These contactor relays are designed with: •4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)•control circuit: AC operated•add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.Number of contactsRated control circuitTy pe Order codeWeight1st stack2nd stackvoltagePkg(1 pce)Uc(1)V 50 HzV 60 Hzkg43NONO4431NCNC3221NCNC2213NONO14A1A22424NS22E-201SBH101001R20220.220230230NS22E-261SBH101001R26220.22033NONO3421NCNC2213NONO1443NONO44A1A22424NS31E-201SBH101001R20310.220230230NS31E-261SBH101001R26310.22043NONO4433NONO3423NONO2413NONO14A1A22424NS40E-201SBH101001R20400.220230230NS40E-261SBH101001R26400.22043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A22424NS44E-201SBH101001R20440.260230230NS44E-261SBH101001R26440.26043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A22424NS53E-201SBH101001R20530.260230230NS53E-261SBH101001R26530.26043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A22424NS62E-201SBH101001R20620.260230230NS62E-261SBH101001R26620.26043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A22424NS71E-201SBH101001R20710.260230230NS71E-261SBH101001R26710.26043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A22424NS80E-201SBH101001R20800.260230230NS80E-261SBH101001R26800.260Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 6071550 1.97"60 2.36"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"35 1.38"ø 4.2 0.17"2 x M4 8-32 UNCNS22E, NS31E, NS40ENS44E, NS53E, NS62E, NS71E, NS80E—NS contactor relaysAC operated Main dimensions mm, inches5/30ABB MOTOR PROTECTION AND CONTROL05
1SBC101479S0201 - Rev. A1SBC101018F0014NSL22ENSL contactor relays are used for switching auxiliary and control circuits.These contactor relays are designed with: • 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)• control circuit: low coil consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)• add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.Number of contactsRated control circuitTy pe Order codeWeight1st stack2nd stackvoltagePkg(1 pce)Uc(1)V DCkg43NONO4431NCNC3221NCNC2213NONO14A1+A2-24NSL22E-811SBH103001R81220.28033NONO3421NCNC2213NONO1443NONO44A1+A2-24NSL31E-811SBH103001R81310.28043NONO4433NONO3423NONO2413NONO14A1+A2-24NSL40E-811SBH103001R81400.28043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-24NSL44E-811SBH103001R81440.32043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-24NSL53E-811SBH103001R81530.32043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-24NSL62E-811SBH103001R81620.32043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-24NSL71E-811SBH103001R81710.32043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-24NSL80E-811SBH103001R81800.320Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 6071560 2.36"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"35 1.38"ø 4.2 0.17"2 x M4 8-32 UNCNSL22E, NSL31E, NSL40ENSL44E, NSL53E, NSL62E, NSL71E, NSL80E—NSL contactor relaysDC operated Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/3105
1SBC101298S02015/32ABB MOTOR PROTECTION AND CONTROLTEF3CA3—NS and NSL contactor relaysMain accessoriesMain accessory fitting detailsContactortypesMainpolesFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksElectronic timer1-pole CA3TEF3Surge suppressorsNS..2 2E2 max.or 1+RV5or RC5-1NS..3 1ENS..4 0ENS..4 4E––RV5or RC5-1NS..5 3ENS..6 2ENS..7 1ENS..8 0ENSL..2 2E2 max.or 1+RV5or RT5NSL..3 1ENSL..4 0ENSL..4 4E––RV5or RT5NSL..5 3ENSL..6 2ENSL..7 1ENSL..8 0EContactor relays and main accessories (other accessories available)4-pole contactor relayNSNSLContactor relaysRV5, RT5 or RC5-1Surge suppressor8-pole contactor relayRV5, RT5 or RC5-1Surge suppressorNSNSLContactor relaysCA-31-pole auxiliary contact block05
1SBC101298S0201 ABB MOTOR PROTECTION AND CONTROL 5/33—NS and NSL contactor relaysMain accessoriesFront-mounted instantaneous auxiliary contact blocksFor contactor relaysAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgNS, NSL1 0CA3-101SBN011010T1010100.0110 1CA3-011SBN011010T1001100.011Front-mounted electronic timer For contactorsRated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)V kgON-delayNS, NSL24...240 V AC/DCTEF3-ON1SBN021012R100010.065OFF-delayNS, NSL24...240 V AC/DCTEF3-OFF1SBN021014R100010.065Surge suppressorsFor contactor relaysRated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)VACDCkgNS, NSL24...50RV5/501SBN050010R100020.01550...133RV5/1331SBN050010R100120.015110...250RV5/2501SBN050010R100220.015250...440RV5/4401SBN050010R100320.015NS24...50–RC5-1/501SBN050100R100020.01250...133–RC5-1/1331SBN050100R100120.012110...250–RC5-1/2501SBN050100R100220.012250...440–RC5-1/4401SBN050100R100320.012NSL12...32–RT5/321SBN050020R100020.01525...65–RT5/651SBN050020R100120.01550...90–RT5/901SBN050020R100220.01577...150–RT5/1501SBN050020R100320.015150...264–RT5/2641SBN050020R100420.0151SBC101036F0014CA3-101SBC574001F0301RV51SBC101337F0014TEF3-ON05
1SBC101502S02015/34ABB MOTOR PROTECTION AND CONTROLContact utilization characteristics according to IECContactor relay typesAC operatedNSDC operatedNSLStandardsIEC 60947-5-1 and EN 60947-5-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ith - θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device for contactorsUe ≤ 500 V AC - gG type fuse10 ARated short-time withstand current Icwfor 1.0 s100 Afor 0.1 s140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7 Non-overlapping time between N.O. and N.C. contacts1.5 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Contact utilization characteristics according to UL / CSAContactor relay typesAC operatedNSDC operatedNSLStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—NS and NSL contactor relaysTechnical data05
1SBC101502S0201 ABB MOTOR PROTECTION AND CONTROL 5/35Magnet system characteristics for NS contactor relaysContactor relay typesAC operatedNSCoil operating limits AC supplyacc. to IEC 60947-5-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)AC control voltageRated control circuit voltage Ucat 50 Hz 24...415 Vat 60 Hz 24...415 VCoil consumptionAverage pull-in value50 Hz 33 VA60 Hz 33 VA50/60 Hz 33 VAAverage holding value50 Hz 6.5 VA / 1.5 W60 Hz 5 VA / 1.2 W50/60 Hz 6.5 VA / 1.5 WDrop-out voltageApprox. 30...50 % of UcOperating timeBetween coil energization and:N.O. contact closing9...24 msN.C. contact opening6...18 msBetween coil de-energization and:N.O. contact opening (1) 5...19 msN.C. contact closing (1) 7...22 ms(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.Magnet system characteristics for NSL contactor relaysContactor relay typesDC operatedNSLCoil operating limits DC supplyacc. to IEC 60947-5-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)DC control voltageRated control circuit voltage Uc12...240 V DCCoil consumptionAverage pull-in value3 WAverage holding value3 WDrop-out voltageApprox. 10...40 % of UcCoil time constantOpenL/R12 msClosedL/R40 msOperating timeBetween coil energization and:N.O. contact closing36...59 msN.C. contact opening31...53 msBetween coil de-energization and:N.O. contact opening (1) 13...17 msN.C. contact closing (1) 15...20 ms(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2.Mounting characteristics and conditions for useContactor relay typesAC operatedNSDC operatedNSLMounting positionsPos. 3Pos. 2Pos. 1Pos. 4Pos. 5Mounting distancesThe contactor relays can be assembled side by side.FixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally—NS and NSL contactor relaysTechnical data05
1SBC101502S02015/36ABB MOTOR PROTECTION AND CONTROLGeneral technical dataContactor relay typesAC operatedNSDC operatedNSLRated insulation voltage Uiacc. to IEC 60947-5-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVAmbient air temperature close to contactor relayOperation in free air-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles20 millions operating cyclesMax. switching frequency3600 cycles/hShock withstand1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionacc. to IEC 60068-2-27 and EN 60068-2-27Shock directionNS contactor relays - AC operatedNSL contactor relays - DC operatedMounting position 1B2AAB1C2C1A20 g20 g closed position / 10 g open positionB1 5 g15 g closed position / 5 g open positionB2 15 g10 gC1 19 g closed position / 8 g open position19 g closed position / 8 g open positionC2 16 g closed position / 13 g open position14 g closed position / 8 g open positionVibration withstand acc. to IEC 60068-2-65...300 Hz / 3 g closed position / 2 g open positionConnecting characteristicsContactor relay typesAC operatedNSDC operatedNSLMain terminalsScrew terminals with cable clampConnection capacity (min. ... max.)Pole and coil terminalsRigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlLugsL ≤ 7.7 mml >3.2 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length9 mmTightening torqueRecommended1.00 Nm / 9 lb.inMax.1.20 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529All terminalsIP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3Screwdriver typeFlat Ø 5.5 / Pozidriv 2—NS and NSL contactor relaysTechnical data05
—Notes05 ABB MOTOR PROTECTION AND CONTROL 5/37
1SBC101410S02015/38ABB MOTOR PROTECTION AND CONTROL-1NC-2-1-2NC—NS contactor relaysTerminal marking and positioningA1A21323 33435361 7181NO1424 34NONONONONONONONCNCNCNO445462 7282A1A21321 3143NO1422 32NONCNCNCNCNONO44NS22ENS53EA1A21323 33435361 7183NO1424 34NONONONONONONONONCNCNO445462 7284A1A21321 3343NO1422 34NONONONCNCNONO44NS31ENS62EA1A21323 33435361 7383NO1424 34NONONONONONONONONONCNO445462 7484A1A21323 3343NO1424 34NONONONONONONO44NS40ENS71EA1A21323 33435363 7383NO1424 34NONONONONONONONONONONO445464 7484A1A21323 33435161 7181NO1424 34NONONONONONONONCNCNCNC445262 7282NS44ENS80E43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A243NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A243NONO4431NCNC3221NCNC2213NONO14A1A243NONO4433NONO3423NONO2413NONO14A1A2NS22ENS40ENS71ENS53E43NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A243NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A233NONO3421NCNC2213NONO1443NONO44A1A243NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A2NS31ENS44ENS80ENS62ENS contactor relays - AC operatedStandard devices without addition of auxiliary contact blocksOther possible contact combinations with auxiliary contact blocks added by the userA1A21323 33431424 3444A1A21323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-3-4NO-3-4NO5-5-6-6-5354NO6364NOA1A21323 33431424 3444A1A21323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-1-2NC-1-2NC5-5-6-6-5152NC6162NCCombination 60E=NS40ECA3-10CA3-10++Combination 42E=NS40ECA3-01CA3-01++A1A21321 3343NO1422 34NO44A1A21321 3343NO1422 34NONONONCNCNONONONONCNCNONO44=+-3-4NO5-5-5354NOA1A21323 3343NO1424 34NO44A1A21323 3343NO1424 34NONONONONONONONONONONONONO44=+-3-4NO5-5-5354NOCombination 50E=NS40ECA3-10+Combination 41E=NS31ECA3-10+43NONO4433NONO3423NONO2413NONO1453NONO54A1 A2 43NONO4433NONO3423NONO2413NONO1463NONO6453NONO54A1 A2 33NONO3421NCNC2213NONO1443NONO4453NONO54A1 A2 43NONO4433NONO3423NONO2413NONO14A1 A2 61NCNC6251NCNC52Combination 50ECombination 60ECombination 41ECombination 42ECA3 1-pole auxiliary contact blocks-3NO-4-3-4NOCA3-10CA3-01 55NC67NONC56NO6855566768NCNOTEF3 front-mounted electronic timerTEF305
1SBC101410S0201 ABB MOTOR PROTECTION AND CONTROL 5/39—NSL contactor relaysTerminal marking and positioningA1+A2-1323 33435361 7181NO1424 34NONONONONONONONCNCNCNO445462 7282A1+A2-1321 3143NO1422 32NONCNCNCNCNONO44NSL53ENSL22EA1+A2-1323 33435361 7183NO1424 34NONONONONONONONONCNCNO445462 7284A1+A2-1321 3343NO1422 34NONONONCNCNONO44NSL62ENSL31EA1+A2-1323 33435361 7383NO1424 34NONONONONONONONONONCNO445462 7484A1+A2-1323 3343NO1424 34NONONONONONONO44NSL71ENSL40EA1+A2-1323 33435363 7383NO1424 34NONONONONONONONONONONO445464 7484A1+A2-1323 33435161 7181NO1424 34NONONONONONONONCNCNCNC445262 7282NSL80ENSL44E43NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-33NONO3421NCNC2213NONO1443NONO44A1+A2-43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-NSL80ENSL44ENSL62ENSL31E43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-43NONO4431NCNC3221NCNC2213NONO14A1+A2-43NONO4433NONO3423NONO2413NONO14A1+A2-NSL71ENSL40ENSL53ENSL22ENSL contactor relays - DC operated (the polarity A1+, A2- must be respected)Standard devices without addition of auxiliary contact blocksA1+A2-1323 33431424 3444A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-3-4NO-3-4NO5-5-6-6-5354NO6364NOA1+A2-1323 33431424 3444A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-1-2NC-1-2NC5-5-6-6-5152NC6162NCCombination 60E=NSL40ECA3-10CA3-10++Combination 42E=NSL40ECA3-01CA3-01++A1+A2-1321 3343NO1422 34NO44A1+A2-1321 3343NO1422 34NONONONCNCNONONONONCNCNONO44=+-3-4NO5-5-5354NOA1+A2-1323 3343NO1424 34NO44A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONO44=+-3-4NO5-5-5354NOCombination 50E=NSL40ECA3-10+Combination 41E=NSL31ECA3-10+43NONO4433NONO3423NONO2413NONO1453NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1463NONO6453NONO54A1+A2-33NONO3421NCNC2213NONO1443NONO4453NONO54A1+A2-43NONO4433NONO3423NONO2413NONO14A1+A2-61NCNC6251NCNC52Combination 50ECombination 41ECombination 60ECombination 42EOther possible contact combinations with auxiliary contact blocks added by the user-3NO-4-3-4NO-1NC-2-1-2NCCA3 1-pole auxiliary contact blocksCA3-10CA3-01 55NC67NONC56NO6855566768NCNOTEF3 front-mounted electronic timerTEF305
1SBC101411S02015/4 0ABB MOTOR PROTECTION AND CONTROL—NS contactor relaysDimensions72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"50 1.97"60 2.36"35 1.38"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNCNS22E, NS31E, NS40E50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"ø 4.2 0.17"2 xM4 8-32 UNCNS22E, NS31E, NS40E+ CA3 front-mounted 1-pole auxiliary contact block4-pole contactor relays50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"ø 4.2 0.17"2 xM4 8-32 UNCNS44E, NS53E, NS62E, NS71E, NS80E8-pole contactor relaysNS22E, NS31E, NS40E+ TEF3 electronic timer100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"1.1 0.05"35 mm EN/IEC 6071544.2 1.74"128.1 5.04"ø 4.2 0.17"2 xM4 8-32 UNC44.4 1.75"Main dimensions mm, inches05
1SBC101411S0201 ABB MOTOR PROTECTION AND CONTROL 5/41—NSL contactor relaysDimensions60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNCNSL22E, NSL31E, NSL40E45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCNSL22E, NSL31E, NSL40E+ CA3 front-mounted 1-pole auxiliary contact block4-pole contactor relays45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715100.2 3.94"44.2 1.74"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCNSL44E, NSL53E, NSL62E, NSL71E, NSL80E8-pole contactor relaysNSL22E, NSL31E, NSL40E+ TEF3 electronic timer100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"1.1 0.05"35 mm EN/IEC 6071544.2 1.74"128.1 5.04"ø 4.2 0.17"2 xM4 8-32 UNC44.4 1.75"Main dimensions mm, inches05
1SBC101492S02015/4 2ABB MOTOR PROTECTION AND CONTROLCA3-10—Auxiliary contact blocksAccessoriesThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.CA3 1-pole auxiliary contact blocks, designed for standard industrial environments, are equipped with:•N.O. or N.C. contacts.•Screw-type connecting terminals with cage clamp delivered open.All 1-pole auxiliary contact blocks are protected against accidental direct contact and bear the corresponding function marking.A maximum of two 1-pole auxiliary contact blocks can be front-mounted on 1-stack contactors or 1-stack contactor relays.For contactorsFor contactor relaysContact blocksType Order codePkg qtyWeight(1 pce) kg1-pole auxiliary contact blocks with screw terminalsAS09 ... AS16ASL09 ... ASL16NS, NSL1–CA3-101SBN011010T1010100.011–1CA3-011SBN011010T1001100.0111SBC101036F0014100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071544.2 1.74"100.2 3.94"Main dimensions mm, inches05
1SBC101493S0201 ABB MOTOR PROTECTION AND CONTROL 5/43—Auxiliary contact blocks Technical dataContact utilization characteristics according to IECTy pes1-pole CA3StandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp6 kVRated operational voltage Ue max.690 VConventional thermal current Ith - θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-1324 V DC 6 A / 144 Wacc. to IEC 60947-5-148 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Power dissipation per pole at 6 A0.1 WMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contacts acc. to annex L of IEC 60947-5-1Additional N.O. or N.C. auxiliary contacts (CA3) are mechanically linked contactsMirror contactsacc. to annex F of IEC 60947-4-1Additional N.C. auxiliary contacts (CA3) are mirror contactsContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage690 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VAConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlLugsL ≤ 7.7 mml >3.2 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length9 mmTightening torqueRecommended1 Nm / 9 Ib.inMax.1.20 NmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals must be tightenedAll terminalsM3Screwdriver typeFlat Ø 5.5 / Pozidriv 205
1SBC101932S02015/4 4ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for AS09 ... AS16, ASL09 ... ASL16 contactors and NS, NSL contactor relaysElectrical durabilityMillions of operating cyclesBreaking current Ic (A)Electrical durability for AC-15 utilization category - Ue ≤ 400 VAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:•making current: 10 x Ie with cos φ = 0.7 and Ue•breaking current: Ie with cos φ = 0.4 and Ue.This curve represents the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.The curve has been drawn for resistive and inductive loads up to 400 V:•AS09 ... AS16 and ASL09 ... ASL16 contactor built-in auxiliary contacts•1-pole CA3•NS and NSL contactor relays.Example:Breaking current = 1.3 AOn the opposite curve at intersection "" 1.3 A the corresponding value for the electrical durability is approximately 2 millions oper-ating cycles.0.020.050.10.30.51245100.10.20.30.51235102030360.21.31357905
1SBC101504S0201 ABB MOTOR PROTECTION AND CONTROL 5/45TEF3-OFFTEF3-ON—Electronic timersTEF3 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFF-delay versions.Compact solution in cabinet compared to separate timersTEF3 electronic timers are front-mounted and locked on AS/ASL contactors or NS/NSL contactor relays. A mechanical indicator allows to show the state of the contactor.Safe and cost-reduced wiringTEF3 electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil.Available for a wide control voltage range 24...240 V AC/DCTEF3-ON or TEF3-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted by means of a rotary switch. The timing function is activated by closing or opening the device on which the timer is mounted. The OFF-delay version operates without additional control supply.For contactors,contactor relaysTime delay rangeselected by switchDelaytypeRated control circuit voltage UcAuxiliary contactsTy pe Order codeWeightPkg(1 pce)V 50/60 Hz or DCkgAS09 ... AS16ASL09 ... ASL16NS, NSL0.1...1 s1...10 s10...100 sON-delay24...2401 1TEF3-ON1SBN021012R10000.065OFF-delay24...2401 1TEF3-OFF1SBN021014R10000.065100.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"1.1 0.05"35 mm EN/IEC 6071544.2 1.74"128.1 5.04"ø 4.2 0.17"2 xM4 8-32 UNC44.4 1.75"1SBC101336F00101SBC101337F0010Main dimensions mm, inches05
1SBC101505S0201 - Rev. B5/4 6ABB MOTOR PROTECTION AND CONTROL—Electronic timersTechnical dataContact utilization characteristics according to IECTy pesTEF3-ONTEF3-OFFStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1400 VRated impulse withstand voltage Uimp4 kVRated operational voltage Ue max.240 VRated frequency (without derating)50 / 60 HzConventional thermal current Ith - θ ≤ 40 °C5 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz3 A220-240 V 50/60 Hz1.5 AMaking capacity acc. to IEC 60947-5-110 x Ie AC-15Breaking capacity acc. to IEC 60947-5-110 x Ie AC-15Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 1 A / 24 WShort-circuit protection device gG type fuse6 ARated short-time withstand current Icwfor 1.0 s8 Aθ = 40 °Cfor 0.1 s8 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-424 V DC 10-7Power dissipation per pole at 3 A0.1 WFunction diagramON-delayOFF-delayUc (A1 - A2)N.O. (67 - 68)t100 msmin.150 msmin.N.C. (55 - 56)Uc (A1 - A2)N.O. (67 - 68)t100 msmin.1 smin.N.C. (55 - 56)Bistable relay inside. Before use, once apply Uc then switch it off in order to initialize position of the contacts.Control circuit voltage AC control voltageRated control circuit voltage Uc24...240 V AC50/60 HzAverage consumption1.5 mA RMS1 mA RMSDC control voltage Rated control circuit voltage Uc24...240 V DCAverage consumption1.5 mA1 mARated frequency limits50 / 60 HzSupply voltage range0.85...1.1 x Uc (at θ ≤ 70 °C)Overvoltage protectionVaristor includedTime delay range (t) selected by switch0.1...1 s1...10 s10...100 sOn-load reiteration accuracy under constant conditions≤ 1 %Minimum ON period0.1 s1 sRecovery time0.15 s0.1 sAmbient air temperatureOperation-25 °C ... +70 °CStorage-40 °C ... +80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude2000 mMounting positionsMounting positions 1, 1 +/- 30°, 2, 3, 4, 5Shock withstand1/2 sinusoidal shock for 11 ms: no change in contact positionacc. to IEC 60068-2-27 and EN 60068-2-27Same as contactor or contactor relay(Mounting position 1)Vibration withstand5...300 Hzacc. to IEC 60068-2-63 g closed position / 2 g open positionMechanical durabilityNumber of operating cycles5 millions operating cyclesMax. switching frequency3600 cycles/h1800 cycles/hMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/h05
1SBC101505S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 5/47—Electronic timersTechnical dataContact utilization characteristics according to UL / CSATy pesTEF3-ONTEF3-OFFStandardsUL 508, CSA C22.2 N°14Rated insulation voltage Ui acc. to UL / CSA300 VMax. operational voltage240 VPilot dutyB300, R300AC thermal rated current5 AAC maximum volt-ampere making3600 VAAC maximum volt-ampere breaking360 VADC thermal rated current1 ADC maximum volt-ampere making-breaking28 VAConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...1.5 mm²LlLugsL ≤ 7.7 mml >3.2 mmConnection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length9 mmTightening torqueRecommended1 N.m / 9 lb.inMax.1.20 N.mDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsDelivered in open position, screws of unused terminals should be tightenedAll terminalsM3 Screwdriver typeFlat Ø 5.5 / Pozidriv 2Terminal MarkingA1A256 NC68 NO55 NC67 NOKM1A1A256 NC68 NO55 NC67 NOKM1240110100101001000Voltage (V)Breaking power (W)1.106 cyclesElectrical durability for DC-13 utilization categoryDC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1 : making and breaking current Ie and Ue.05
1SBC101494S02015/4 8ABB MOTOR PROTECTION AND CONTROL—Surge suppressors for contactor coilsThe operation of inductive circuits causes overvoltages, in particular on opening the contactor coil.The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to the breakdown of insulators and even the destruction of certain sensitive components.The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.Following a burst of discharges with a very steep slope, a damped oscillation emerges with a peak value of 3500 V.Overvoltage FactorThe overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil rated control voltage Uc:Ûs max.k = Ûc Ûs max.in DC k = Uc Ûs max.in AC k = Uc √2For example the following is obtained for the above graph: 3500k = ≈ 6042 √2To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppres-sors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies.Each case is different, but the technical data tolerances and generous sizing of parts have enabled us to reduce the number of variants.We have chosen the following solutions: transil diodes, varistors and RC blocks.Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.For contactors For contactor relaysRated control circuit voltage - UcTy pe Order codePkg qtyWeight(1 pce)VACDCkgAS, ASLNS, NSL24...50●●RV5/501SBN050010R100020.01550...133●●RV5/1331SBN050010R100120.015110...250●●RV5/2501SBN050010R100220.015250...440●●RV5/4401SBN050010R100320.015ASNS24...50●–RC5-1/501SBN050100R100020.01250...133●–RC5-1/1331SBN050100R100120.012110...250●–RC5-1/2501SBN050100R100220.012250...440●–RC5-1/4401SBN050100R100320.012ASLNSL12...32–●RT5/321SBN050020R100020.01525...65–●RT5/651SBN050020R100120.01550...90–●RT5/901SBN050020R100220.01577...150–●RT5/1501SBN050020R100320.015150...264–●RT5/2641SBN050020R100420.01501000100 (V)T (μs)01000100RV51SBC101042F0014RT51SBC101042F0014RC5-11SBC101042F001472.5 2.85"45 1.77"68 2.68"45 1.77"68 2.68"Easy connection to the coil terminals (parallel mounting)Clip-on for both fixing and connection.No additional spaceClipped onto the right side part of the contactor base without changing con-tactor overall dimensions and keeping a free access to coil terminals.Main dimensions mm, inches05
1SBC101602S0201 ABB MOTOR PROTECTION AND CONTROL 5/49—Surge suppressors for contactor coilsTechnical dataVaristorRV5/50RV5/133RV5/250RV5/4 4 0Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V AC24...50 V DC50...133 V DC110...250 V DC250...440 V DCResidual overvoltage (clipping voltage)132 V AC 270 V AC480 V AC825 V AC132 V DC 270 V DC480 V DC825 V DCOpening time growth factornoneOperating temperature-20...+70 °CAdvantagesHigh energy absorption: good damping - Unpolarized system.DrawbackClipping as from Uvdr*, thus voltage front up to this point.*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %.RC typeRC5-1/50RC5-1/133RC5-1/250RC5-1/440Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V ACResidual overvoltage (clipping voltage)2 to 3 x Uc max.Opening time growth factor2...3Operating temperature-20...+70 °CAdvantagesVery fast clipping - Attenuation of steep fronts and thus of high frequencies.Transil diodeRT5/32RT5/65RT5/90RT5/150RT5/264Rated control circuit voltage Uc12...32 V DC25...65 V DC50...90 V DC77...150 V DC150...264 V DCResidual overvoltage (clipping voltage)50 V DC100 V DC150 V DC210 V DC390 V DCOpening time growth factor1.1...1.2Operating temperature-20...+70 °CAdvantagesGood energy absorption - Unpolarized system - Simple, reliable system.DrawbackDelay on drop out which does not however reduce contactor breaking capacity.Wiring diagramsA1A2E0733DA1A2E0735DA1A2E0734DTransil diodeVaristorRC type05
1SBC101496S0201 - Rev. A5/50ABB MOTOR PROTECTION AND CONTROL—Mechanical interlock unit and other accessoriesMechanical interlock unitWhen mounted between two contactors without additional width, the VM3 mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed.The mechanical interlock unit includes 2 fixing clips.For contactors Ty pe Order codePkg qtyWeight(1 pce)LeftRightkgASASVM31SBN031005T1000100.002ASLASLNote : VM3 mechanical durability, 5 millions of operating cycles on both reversing contactors.Fixing clipsBB3 is a set of 50 fixing clips.For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAS, ASLBB31SBN111020R100010.009Test blockBDT4 test block is suitable for switching on contactor off-load. Marking on the block indicates the contactor type to fit with.For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAS, ASL, NS, NSLBDT41SBN110122T1000100.007Function markersBox of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking table to identify your contactors, overload relays or manual motor starters. Marker dimensions: 7 x 20 mm (.276" x .787").For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAS, ASL, NS, NSLBA41SNA235156R2700160.011AMS 500 support plate for 8 BA4SPRC 11SNA360010R150010.220HTP500 support plateHTP500-BA41SNA235712R240010.290VM3BB31SBC100043V0014B DT4BA41SNC160101F001405
1SBC101495S0201 ABB MOTOR PROTECTION AND CONTROL 5/51—Connection accessories for starting solutionsConnecting linksThe BEA16-3 insulated 3-pole connecting links are used to connect an AC or DC operated contactors with manual motor starters. The connecting links ensure the electrical and mechanical connection between the contactor and the manual motor starter.For contactors Manual motor starterType Order codePkg qtyWeight(1 pce)kgAS09 ... AS16 ASL09 ... ASL16MS116-0.16 ... MS116-16 MS132-0.16 ... MS132-16BEA16-31SBN081006T1000100.019Connection sets for reversing contactorsThe BER16C-3 connection sets are used for the connections between the main poles of two 3-pole contactors mounted side by side as reversing contactors, including electrical interlocking between built-in N.C. auxiliary contact and coil terminals.The connection sets are made up of:• 1 upstream and 1 downstream connections: insulated, solid copper bars,• 2 connections to realize electrical interlocking between contactors equipped with built-in N.C. auxiliary contacts,• 2 fixing clips.For contactors Mechanical interlock unitType Order codePkg qtyWeight(1 pce)kg2 x AS09 ... AS16 2 x ASL09 ... ASL16with or without VM3BER16C-31SBN081012R100010.035Connection sets for star-delta startingBEY16C-3 connection sets are designed for star-delta starters whose contactors are assembled according to line delta star mounting.The connection sets are made up of:• Line contactor / delta contactor: upstream phase-to-phase connection,• Delta contactor / star contactor: downstream connection in parallel,• Star contactor: star point upstream,• An electrical interlocking between delta and star contactors equipped with built-in N.C. auxil-iary contacts,• 4 fixing clips.For contactors Mech. interlock unit between star & delta contactorsTy pe Order codePkg qtyWeight(1 pce)LineDeltaStarkgAS09AS09AS09with or without VM3BEY16C-31SBN081018R200010.041AS12AS12AS09BEA16-31SBC101034F0014BER16C-31SBC101071F00141SBC101070F0014BEY16C-305
1SBC101600S02015/52ABB MOTOR PROTECTION AND CONTROL—Voltage code tableThe below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give either type or order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the type or in the order code according to the table below. Example: for contactor AS09-30-10 and coil 42 V 50/60 Hz, type is AS09-30-10-21 and order code is 1SBL101001R2110.Auxiliary contacts N.O. N.C.N.O. N.C. Number contacts N.O. N.C. Main contactsTy peTy peOrder codeOrder codeContactor typeContactor typeAS16 - 30 -10-26NS 40 E -26AS AC operatedASL DC operatedNS AC operatedNSL DC operatedAC coil codeAC coil code50 Hz 60 Hz20 24 V 24 V21 42 V 42 V22 48 V 48 V23 110 V 110 V24 115 V 115 V16 –120 V25 220 V 220 V26 230 V 230 V27 240 V 240 V17 –277 V13 380 V –28 400 V 400 V29 415 V 415 V50 Hz 60 Hz20 24 V 24 V21 42 V 42 V22 48 V 48 V23 110 V 110 V24 115 V 115 V16 –120 V25 220 V 220 V26 230 V 230 V27 240 V 240 V17 –277 V13 380 V –28 400 V 400 V29 415 V 415 V1SBL121001R26101SBH101001R2640DC coil code80 12 V81 24 V83 48 V84 60 V86 110 V87 125 V88 220 V89 240 VDC coil code80 12 V81 24 V83 48 V84 60 V86 110 V87 125 V88 220 V89 240 V3-pole contactorsContactor relays05
ABB MOTOR PROTECTION AND CONTROL 5/5305—Notes
05
ABB MOTOR PROTECTION AND CONTROL 5/55— For direct product details information, use product type or order code, ex:• www.abb.com/productdetails/AF09-30-10-13 • or www.abb.com/productdetails/1SBL137001R1310 AS..S 3-pole contactors - with spring terminals5/56 AS09..S ... AS16..S AC operated5/57 ASL09..S ... ASL16..S DC operated5/58 AS09..S ... AS16..S AC operated - 2-stack5/59 ASL09..S ... ASL16..S DC operated - 2-stack5/60 Main accessories5/62 Technical data5/68 Electrical durability5/69 Terminal marking and positioning5/71 Main dimensions NS..S contactors relays - with spring terminals 5/73 NS..S AC operated5/74 NSL..S DC operated5/75 Main accessories5/77 Technical data5/80 Terminal marking and positioning5/82 Main dimensions Accessories5/84 Auxiliary contact blocks - with spring terminals5/88 Surge suppressors for contactor coils5/90 Connecting links for starting solution and other accessories5/91 Voltage code table —AS..S 3-pole contactors and NS..S contactor relays with spring terminals05
1SBC101454S0201—AS09..S ... AS16..S 3-pole contactors4 to 7.5 kWAC operated - with spring terminalsAS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:•spring terminals•3 main poles and 1 built-in auxiliary contact •control circuit: AC operated•add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.IECUL/CSARated controlcircuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightRated operational3-phasemotorrating480 VGeneraluserating600 V ACpower 400 Vcurrentθ ≤ 40 °CPkg(1 pce)AC-3AC-1kWAhpAV 50 Hz V 60 Hzkg42051224241 0AS09-30-10S-201SBL101004R20100.2200 1AS09-30-01S-201SBL101004R20010.2202302301 0AS09-30-10S-261SBL101004R26100.2200 1AS09-30-01S-261SBL101004R26010.2205.5227.51224241 0AS12-30-10S-201SBL111004R20100.2200 1AS12-30-01S-201SBL111004R20010.2202302301 0AS12-30-10S-261SBL111004R26100.2200 1AS12-30-01S-261SBL111004R26010.2207.5221015.224241 0AS16-30-10S-201SBL121004R20100.2200 1AS16-30-01S-201SBL121004R20010.2202302301 0AS16-30-10S-261SBL121004R26100.2200 1AS16-30-01S-261SBL121004R26010.220Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.50 1.97"60 2.36"35 1.38"72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"AS09..S, AS12..S, AS16..S1SBC101009F0014AS09-30-10SMain dimensions mm, inches5/56ABB MOTOR PROTECTION AND CONTROL05
1SBC101455S0201 - Rev. A1SBC101011F0014ASL09-30-10SASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:• spring terminals• 3 main poles and 1 built-in auxiliary contact • control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core mag-net. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)• add-on auxiliary contact blocks for front mounting and comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightRated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 Vcurrentθ ≤ 40 °CPkg(1 pce)AC-3AC-1kWAhpAV DCkg420512241 0ASL09-30-10S-811SBL103004R81100.2800 1ASL09-30-01S-811SBL103004R81010.2805.5227.512241 0ASL12-30-10S-811SBL113004R81100.2800 1ASL12-30-01S-811SBL113004R81010.2807.5221015.2241 0ASL16-30-10S-811SBL123004R81100.2800 1ASL16-30-01S-811SBL123004R81010.280Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"ASL09..S, ASL12..S, ASL16..S—ASL09..S ... ASL16..S 3-pole contactors4 to 7.5 kWDC operated - with spring terminals Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/5705
1SBC101456S0201 - Rev. A—AS09..S ... AS16..S 2-stack 3-pole contactors4 to 7.5 kWAC operated - with spring terminalsAS09..S ... AS16..S contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:•spring terminals•1st stack with 3 main poles and 1 N.O. built-in auxiliary contact•2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block•the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxil-iary contacts are mirror contacts• control circuit: AC operated•a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliarycontactsfittedTy pe Order codeWeightRated operational3-phasemotorrating480 VGeneraluserating600 V ACpower400 Vcurrentθ ≤ 40 °CPkg(1 pce)AC-3AC-1kWAhpAV 50 HzV 60 Hzkg42051224243 2AS09-30-32S-201SBL101004R20320.2602302303 2AS09-30-32S-261SBL101004R26320.2605.5227.51224243 2AS12-30-32S-201SBL111004R20320.2602302303 2AS12-30-32S-261SBL111004R26320.2607.5221015.224243 2AS16-30-32S-201SBL121004R20320.2602302303 2AS16-30-32S-261SBL121004R26320.260Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.10 0.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"AS09..S, AS12..S, AS16..S1SBC101333F0014AS09-30-32SMain dimensions mm, inches5/58ABB MOTOR PROTECTION AND CONTROL05
1SBC101457S0201 - Rev. A1SBC101335F0014ASL09-30-32SASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC.These contactors are of the block type design with:• spring terminals• 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact• 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block• the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxil-iary contacts are mirror contacts• control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core mag-net. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected) • a comprehensive range of accessories.IECUL/CSARated control circuitvoltageUc(1)AuxiliaryTy pe Order codeWeightRated operational3-phasemotorrating480 VGeneraluserating600 V ACcontactspower 400 Vcurrentθ ≤ 40 °CfittedPkg(1 pce)AC-3AC-1kWAhpAV DCkg420512243 2ASL09-30-32S-811SBL103004R81320.3205.5227.512243 2ASL12-30-32S-81 1SBL113004R81320.3207.5221015.2243 2ASL16-30-32S-811SBL123004R81320.320Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.10 0.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"ASL09..S, ASL12..S, ASL16..S—ASL09..S ... ASL16..S 2-stack 3-pole contactors4 to 7.5 kWDC operated - with spring terminals Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/5905
1SBC101412S02015/60ABB MOTOR PROTECTION AND CONTROLRV5, RC5-1 or RT5VM3AS..SASL..SContactorsAS..SASL..SContactorsCA3..SCA3..S—AS09..S ... AS16..S and ASL09..S ... ASL16..S 3-pole contactors - with spring terminals Main accessoriesMain accessory fitting detailsContactortypesMain polesBuilt-inauxiliary contactsFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocksMechanical interlock unit (between 2 contactors)1-pole CA3..SVM3Surge suppressorsAS09..S ... AS16..S3 01 0 2 max.+ 1+RV5or RC5-1AS09..S ... AS16..S3 00 1AS09..S ... AS16..S3 03 2–1+RV5or RC5-1ASL09..S ... ASL16..S3 01 0 2 max.+ 1+RV5or RT5ASL09..S ... ASL16..S3 00 1ASL09..S ... ASL16..S3 03 2–1+RV5or RT5Contactor and main accessories (other accessories available)05
1SBC101412S0201 ABB MOTOR PROTECTION AND CONTROL 5/61BEA16-3U1SBC101384F0010—AS09..S ... AS16..S and ASL09..S ... ASL16..S 3-pole contactors - with spring terminals Main accessoriesFront-mounted instantaneous auxiliary contact blocksFor contactorsAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgAS09..S ... AS16..S1 0CA3-10S1SBN011019T1010100.011ASL09..S ... ASL16..S0 1CA3-01S1SBN011019T1001100.011Mechanical interlock unitFor contactorsTy pe Order codePkg qtyWeight(1 pce) kgAS09..S ... AS16..S, ASL09..S ... ASL16..SVM31SBN031005T1000100.002Surge suppressorsFor contactors Rated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)VACDCkgAS09..S ... AS16..S,ASL09..S ... ASL16..S24...50●●RV5/501SBN050010R100020.01550...133●●RV5/1331SBN050010R100120.015110...250●●RV5/2501SBN050010R100220.015250...440●●RV5/4401SBN050010R100320.015AS09..S ... AS16..S24...50●–RC5-1/501SBN050100R100020.01250...133●–RC5-1/1331SBN050100R100120.012110...250●–RC5-1/2501SBN050100R100220.012250...440●–RC5-1/4401SBN050100R100320.012ASL09..S ... ASL16..S12...32–●RT5/321SBN050020R100020.01525...65–●RT5/651SBN050020R100120.01550...90–●RT5/901SBN050020R100220.01577...150–●RT5/1501SBN050020R100320.015150...264–●RT5/2641SBN050020R100420.015Connecting links with manual motor startersFor contactorsManual motor starterType Order codePkg qtyWeight(1 pce)kgAS09..S ... AS16..S ASL09..S ... ASL16..SMS116-0.16 ... MS116-16 MS132-0.16 ... MS132-16BEA16-3U1SBN081020R100010.0451SBC101069F0014VM31SBC574001F0301RV5CA3-10S1SBC101037F001405
1SBC101490S02015/62ABB MOTOR PROTECTION AND CONTROLMain pole - Utilization characteristics according to IECContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SStandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ithacc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C20 A22 A22 AWith conductor cross-sectional area2.5 mm²2.5 mm²2.5 mm²AC-1 Utilization categoryFor air temperature close to contactorIe / Rated operational current AC-1θ ≤ 40 °C 20 A22 A22 AUe max. ≤ 690 V, 50/60 Hzθ ≤ 60 °C 15 A17 A17 Aθ ≤ 70 °C 12 A14 A14 AWith conductor cross-sectional area2.5 mm²AC-3 Utilization categoryFor air temperature close to contactor θ ≤ 60 °CIe / Max. rated operational current AC-3 (1)M33-phase motors220-230-240 V9 A12 A15.7 A400 V9 A12 A15.5 A415 V9 A12 A15.5 A440 V8 A11 A13.6 A500 V8 A11 A12.5 A690 V5 A7 A9 ARated operational power AC-3 (1)M3220-230-240 V 2.2 kW3 kW4 kW400 V4 kW5.5 kW7.5 kW1500 r.p.m. 50 Hz415 V4 kW5.5 kW7.5 kW1800 r.p.m. 60 Hz440 V4 kW5.5 kW7.5 kW3-phase motors500 V4 kW5.5 kW7.5 kW690 V4 kW5.5 kW7.5 kWRated making capacity AC-310 x Ie AC-3 acc. to IEC 60947-4-1Rated breaking capacity AC-38 x Ie AC-3 acc. to IEC 60947-4-1AC-8a Utilization category(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)Ie / Rated operational current AC-8a12 A16 A22 ARated operational power AC-8a5.5 kW7.5 kW11 kWShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excluded (2)Ue ≤ 500 V AC - gG type fuse25 ARated short-time withstand current Icw1 s230 A250 A250 Aat 40 °C ambient temperature,10 s100 A124 A124 Ain free air from a cold state30 s65 A75 A75 A1 min 50 A55 A55 A15 min 20 A22 A22 AMaximum breaking capacitycos φ = 0.45at 440 V155 Aat 690 V90 APower dissipation per poleIe / AC-1 0.9 W1.1 W1.1 WIe / AC-3 0.18 W0.33 W0.55 WMax. electrical switching frequencyAC-1600 cycles/hAC-31200 cycles/hAC-4300 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".—AS09..S ... AS16..S andASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTechnical data05
1SBC101490S0201 ABB MOTOR PROTECTION AND CONTROL 5/63Main pole - Utilization characteristics according to UL / NEMA / CSAContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SStandardsUL 508, CSA C22.2 N°14Max. operational voltage690 VNEMA size000000NEMA continuous amp ratingThermal current9 ANEMA maximum horse power ratings 1-phase, 60 Hz115 V AC 1/3 hp1/3 hp1/3 hp230 V AC 1 hp1 hp1 hpNEMA maximum horse power ratings 3-phase, 60 Hz200 V AC 1-1/2 hp1-1/2 hp1-1/2 hp230 V AC 1-1/2 hp1-1/2 hp1-1/2 hp460 V AC 2 hp2 hp2 hp575 V AC 2 hp2 hp2 hpUL / CSA General use rating600 V AC12 A12 A15.2 AWith conductor cross-sectional areaAWG 14AWG 14AWG 12UL / CSA maximum 1-phase motor ratingFull load current120 V AC 7.2 A9.8 A13.8 A240 V AC 8 A10 A12 AHorse power rating120 V AC 1/3 hp1/2 hp3/4 hp240 V AC 1 hp1-1/2 hp2 hpUL / CSA maximum 3-phase motor ratingFull load current (1)200-208 V AC 7.8 A7.8 A11 A220-240 V AC 6.8 A9.6 A15.2 A440-480 V AC 7.6 A11 A14 A550-600 V AC 9 A11 A11 AHorse power rating (1)200-208 V AC 2 hp2 hp3 hp220-240 V AC 2 hp3 hp5 hp440-480 V AC 5 hp7-1/2 hp10 hp550-600 V AC 7-1/2 hp10 hp10 hpShort-circuit protection device for contactorswithout thermal overload relay - Motor protection excludedFuse rating40 A50 A60 AFuse type, 600 VJ Max. electrical switching frequencyFor general use 600 cycles/hFor motor use1200 cycles/h(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".General technical dataContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVAmbient air temperature close to contactorOperation-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hShock withstand1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionacc. to IEC 60068-2-27 and EN 60068-2-27Shock directionAS contactors - AC operatedASL contactors - DC operatedMounting position 1B2AAB1C2C1A20 g20 g closed position / 10 g open positionB1 10 g closed position / 5 g open position15 g closed position / 5 g open positionB2 15 g10 gC1 20 g closed position / 9 g open position15 g closed position / 8 g open positionC2 20 g closed position / 14 g open position14 g closed position / 8 g open positionVibration withstandacc. to IEC 60068-2-65...300 Hz / 3 g closed position / 2 g open position—AS09..S ... AS16..S andASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTechnical data05
1SBC101490S02015/64ABB MOTOR PROTECTION AND CONTROLMagnet system characteristics for AS09..S ... AS16..S contactorsContactor typesAC operatedAS09..SAS12..SAS16..SCoil operating limits AC supplyacc. to IEC 60947-4-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)AC control voltageRated control circuit voltage Ucat 50 Hz 24...415 Vat 60 Hz 24...415 VCoil consumptionAverage pull-in value50 Hz 33 VA60 Hz 33 VA50/60 Hz 33 VAAverage holding value50 Hz 6.5 VA / 1.5 W60 Hz 5 VA / 1.2 W50/60 Hz 6.5 VA / 1.5 WDrop-out voltageApprox. 30...50 % of UcOperating timeBetween coil energization and:N.O. contact closing9...24 msN.C. contact opening6...18 msBetween coil de-energization and:N.O. contact opening (1) 5...19 msN.C. contact closing (1) 7...22 ms(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.Magnet system characteristics for ASL09..S ... ASL16..S contactorsContactor typesDC operatedASL09..SASL12..SASL16..SCoil operating limits DC supplyacc. to IEC 60947-4-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)DC control voltageRated control circuit voltage Uc12...240 V DCCoil consumptionAverage pull-in value3 WAverage holding value3 WDrop-out voltageApprox. 10...40 % of UcCoil time constantOpenL/R12 msClosedL/R40 msOperating timeBetween coil energization and:N.O. contact closing36...59 msN.C. contact opening31...53 msBetween coil de-energization and:N.O. contact opening (1) 13...17 msN.C. contact closing (1) 15...20 ms(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2Mounting characteristics and conditions for useContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SMounting positionsPos. 1 ± 30°+30°-30°Pos. 3Pos. 2Pos. 1Pos. 4Pos. 5Mounting distancesThe contactors can be assembled side by side.FixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally—AS09..S ... AS16..S andASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTechnical data05
1SBC101490S0201 ABB MOTOR PROTECTION AND CONTROL 5/65Connecting characteristicsContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SMain terminalsSpring terminalsConnection capacity (min. ... max.)Main conductors (poles)Rigid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...1.5 mm²2 x 0.75...1.5 mm²Connection capacity acc. to UL / CSA1 or 2 x AWG 18...12Stripping length10 mmAuxiliary conductors(built-in auxiliary terminals + coil terminals)Rigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...1.5 mm²2 x 0.75...1.5 mm²Connection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529All terminalsIP20Screwdriver typeFlat Ø 3.5—AS09..S ... AS16..S andASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTechnical data05
1SBC101490S02015/66ABB MOTOR PROTECTION AND CONTROLBuilt-in auxiliary contacts according to IECContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SRated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free air thermal current Ith - θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s100 Afor 0.1 s140 AMinimum switching capacity12 V / 3 mwith failure rate acc. to IEC 60947-5-410-7Non-overlapping time between N.O. and N.C. contacts1.5 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Mirror contactsBuilt-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA3 aux. contact blocks) are mirror contacts.acc. to annex F of IEC 60947-4-1Built-in auxiliary contacts according to UL / CSAContactor typesAC operatedAS09..SAS12..SAS16..SDC operatedASL09..SASL12..SASL16..SMax. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—AS09..S ... AS16..S andASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTechnical data05
ABB MOTOR PROTECTION AND CONTROL 5/6705—Notes
1SBC101946S02015/68ABB MOTOR PROTECTION AND CONTROL—AS09..S ... AS16..S and ASL09..S ... ASL16..S 3-pole contactors - with spring terminalsElectrical durabilityElectrical durability for AC-1 utilization category - Ue ≤ 690 VNote: AC-1 maximum current is selected according to ambient temperature. Please see technical data.Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load. Maximum electrical switching frequency: 600 cycles / hour.135791357913579135791357910.10.20.30.53410235302020.69AS09..SASL09..S, AS12..S, ASL12..S,AS16..S, ASL16..SAS12..S, ASL12..S,AS16..S, ASL16..SASL09..SMillions of operating cyclesBreaking current Ic (A)Example:Breaking current = 9 A.On the opposite curve at intersection "" 9 A the corresponding value for the electrical durability is approximately 0.6 mil-lions operating cycles.05
1SBC101413S0201 ABB MOTOR PROTECTION AND CONTROL 5/69-1NC-2-3NO-4-1-2NC-3-4NOCA3-10SCA3-01S —AS09..S ... AS16..S 3-pole contactors - with spring terminalsTerminal marking and positioningAS..S contactors - AC operatedStandard devices without addition of auxiliary contactsCA3..S 1-pole auxiliary contact blocksOther possible contact combinations with auxiliary contact blocks added by the userA1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L321NC2T14T26T3NC225L33L2A1A26T34T21L12T113NONO145L33L2A1A26T34T21L12T121NCNC22AS09 ... AS16-30-10SAS09 ... AS16-30-01SAS09 ... AS16-30-10SAS09 ... AS16-30-01SA1A21L13L2 5L31353NO2T14T2 6T3NONO43NO31NC21NC54NO44NO32NC22NCNONONCNC145L33L2A1A26T34T21L12T153NONO5443NONO4431NCNC3221NCNC2213NONO14AS09 ... AS16-30-32SAS09 ... AS16-30-32S21NCNC225L33L2A1A26T34T21L12T113NONO14Combination 11Combination 11AS09 ... AS16-30-10S=A1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L313NO2T14T26T3NO14=+-1-2NC2-2-2122NCCA3-01S+21NCNC225L33L2A1A26T34T21L12T113NONO1433NONO34Combination 21Combination 21=AS09 ... AS16-30-10SA1A21L13L25L313NO2T14T26T3NO14A1A21L13L25L313NO2T14T26T3NO14=++-1-2NC-3-4NO2-2-3-3-2122NC3334NOCA3-01SCA3-10S++05
1SBC101413S02015/70ABB MOTOR PROTECTION AND CONTROL—ASL09..S ... ASL16..S 3-pole contactors - with spring terminalsTerminal marking and positioningASL..S contactors - DC operated (the polarity A1+, A2- must be respected)Standard devices without addition of auxiliary contactsOther possible contact combinations with auxiliary contact blocks added by the userA1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L321NC2T14T26T3NC225L33L2A1+A2-6T34T21L12T113NONO145L33L2A1+A2-6T34T21L12T121NCNC22ASL09 ... ASL16-30-10SASL09 ... ASL16-30-01SASL09 ... ASL16-30-10SASL09 ... ASL16-30-01SA1+A2-1L13L2 5L31353NO2T14T2 6T3NONO43NO31NC21NC54NO44NO32NC22NCNONONCNC145L33L2A1+A2-6T34T21L12T153NONO5443NONO4431NCNC3221NCNC2213NONO14ASL09 ... ASL16-30-32ASL09 ... ASL16-30-32S21NCNC225L33L2A1+A2-6T34T21L12T113NONO14A1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L313NO2T14T26T3NO14=+-1-2NC2-2-2122NCCombination 11Combination 11ASL09 ... ASL16-30-10S=CA3-01S+21NCNC225L33L2A1+A2-6T34T21L12T113NONO1433NONO34A1+A2-1L13L25L313NO2T14T26T3NO14A1+A2-1L13L25L313NO2T14T26T3NO14=++-1-2NC-3-4NO2-2-3-3-2122NC3334NOCombination 21Combination 21=ASL09 ... ASL16-30-10SCA3-01SCA3-10S++CA3..S 1-pole auxiliary contact blocks-1NC-2-3NO-4-1-2NC-3-4NOCA3-10SCA3-01S05
1SBC101414S0201ABB MOTOR PROTECTION AND CONTROL 5/71—AS09..S ... AS16..S 3-pole contactors - with spring terminalsDimensions68 2.68"90 3.54"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071550 1.97"60 2.36"80 3.15"ø 4.2 0.17"4 xM4 8-32 UNC10 0.39"AS09..S, AS12..S, AS16..S+ VM3 mechanical interlock unit including two BB3 fixing clips50 1.97"60 2.36"35 1.38"72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"AS09..S, AS12..S, AS16..S10 0.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071535.4 1.39"110.8 4.36"ø 4.2 0.17"2 xM4 8-32 UNCAS09..S, AS12..S, AS16..S+ CA3..S front-mounted 1-pole auxiliary contact blockAS09...16-30-32S10 0.39"50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inches05
1SBC101414S02015/72ABB MOTOR PROTECTION AND CONTROL—ASL09..S ... ASL16..S 3-pole contactors - with spring terminalsDimensions60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNC10 0.39"ASL09..S, ASL12..S, ASL16..S10 0.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071535.4 1.39"110.8 4.36"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCASL09..S, ASL12..S, ASL16..S+ CA3..S front-mounted 1-pole auxiliary contact block68 2.68"90 3.54"60 2.36"4 xM4 8-32 UNC72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071510 0.39"ø 4.2 0.17"80 3.15"ø 4.2 0.17"ASL09..S, ASL12..S, ASL16..S+ VM3 mechanical interlock unit including two BB3 fixing clipsASL09...16-30-32S10 0.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCMain dimensions mm, inches05
1SBC101481S0201 - Rev. A1SBC101015F0014NS22ESNS..S contactor relays are used for switching auxiliary and control circuits.These contactor relays are designed with: • spring terminals• 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)• control circuit: AC operated• add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.Number of contactsRated control circuitvoltageUc(1)Ty pe Order codeWeight1st stack2nd stackPkg(1 pce)V 50 HzV 60 Hzkg43NONO4431NCNC3221NCNC2213NONO14A1A22424NS22ES-201SBH101004R20220.220230230NS22ES-261SBH101004R26220.22033NONO3421NCNC2213NONO1443NONO44A1A22424NS31ES-201SBH101004R20310.220230230NS31ES-261SBH101004R26310.22043NONO4433NONO3423NONO2413NONO14A1A22424NS40ES-201SBH101004R20400.220230230NS40ES-261SBH101004R26400.22043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A22424NS44ES-201SBH101004R20440.260230230NS44ES-261SBH101004R26440.26043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A22424NS53ES-201SBH101004R20530.260230230NS53ES-261SBH101004R26530.26043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A22424NS62ES-201SBH101004R20620.260230230NS62ES-261SBH101004R26620.26043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A22424NS71ES-201SBH101004R20710.260230230NS71ES-261SBH101004R26710.26043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A22424NS80ES-201SBH101004R20800.260230230NS80ES-261SBH101004R26800.260Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 6071545 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"NS22ES, NS31ES, NS40ESNS44ES, NS53ES, NS62ES, NS71ES, NS80ES—NS..S contactor relays - with spring terminalsAC operated Main dimensions mm, inches ABB MOTOR PROTECTION AND CONTROL 5/7305
1SBC101482S0201 - Rev. A1SBC101021F0014NSL22ESNSL..S contactor relays are used for switching auxiliary and control circuits.These contactor relays are designed with:•spring terminals •4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)•control circuit: low coil consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)•add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.Number of contactsRated control circuitvoltageUc(1)Ty pe Order codeWeight1st stack2nd stackPkg(1 pce)V DCkg43NONO4431NCNC3221NCNC2213NONO14A1+A2-24NSL22ES-811SBH103004R81220.28033NONO3421NCNC2213NONO1443NONO44A1+A2-24NSL31ES-811SBH103004R81310.28043NONO4433NONO3423NONO2413NONO14A1+A2-24NSL40ES-811SBH103004R81400.28043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-24NSL44ES-811SBH103004R81440.32043NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-24NSL53ES-811SBH103004R81530.32043NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-24NSL62ES-811SBH103004R81620.32043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-24NSL71ES-811SBH103004R81710.32043NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-24NSL80ES-811SBH103004R81800.320Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071545 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"NSL22ES, NSL31ES, NSL40ESNSL44ES, NSL53ES, NSL62ES, NSL71ES, NSL80ES—NSL..S contactor relays - with spring terminalsDC operatedMain dimensions mm, inches5/ 74ABB MOTOR PROTECTION AND CONTROL05
1SBC101415S0201 ABB MOTOR PROTECTION AND CONTROL 5/75—NS..S and NSL..S contactor relays - with spring terminalsMain accessoriesMain accessory fitting detailsContactortypesMainpolesFront-mounted accessoriesSide-mounted accessoriesAuxiliary contact blocks1-pole CA3..SSurge suppressorsNS..S2 2E2 max.+RV5or RC5-1NS..S3 1ENS..S4 0ENS..S4 4E–RV5or RC5-1NS..S5 3ENS..S6 2ENS..S7 1ENS..S8 0ENSL..S2 2E2 max.+RV5or RT5NSL..S3 1ENSL..S4 0ENSL..S4 4E–RV5or RT5NSL..S5 3ENSL..S6 2ENSL..S7 1ENSL..S8 0EContactor relays and main accessories4-pole contactor relay8-pole contactor relayNS..SNSL..SContactor relaysNS..SNSL..SContactor relaysRV5, RC5-1 or RT5RV5, RC5-1 or RT5CA3..S05
1SBC101415S02015/76ABB MOTOR PROTECTION AND CONTROL—NS..S and NSL..S contactor relays - with spring terminalsMain accessoriesFront mounted instantaneous auxiliary contact blocksFor contactor relaysAuxiliary contactsTy pe Order codePkg qtyWeight(1 pce) kgNS..S, NSL..S1 0CA3-10S1SBN011019T1010100.0110 1CA3-01S1SBN011019T1001100.011Surge suppressorsFor contactor relaysRated control circuit voltage - UcType Order codePkg qtyWeight(1 pce)VACDCkgNS..S, NSL..S24...50●●RV5/501SBN050010R100020.01550...133●●RV5/1331SBN050010R100120.015110...250●●RV5/2501SBN050010R100220.015250...440●●RV5/4401SBN050010R100320.015NS..S24...50●–RC5-1/501SBN050100R100020.01250...133●–RC5-1/1331SBN050100R100120.012110...250●–RC5-1/2501SBN050100R100220.012250...440●–RC5-1/4401SBN050100R100320.012NSL..S12...32–●RT5/321SBN050020R100020.01525...65–●RT5/651SBN050020R100120.01550...90–●RT5/901SBN050020R100220.01577...150–●RT5/1501SBN050020R100320.015150...264–●RT5/2641SBN050020R100420.0151SBC574001F0301RV5CA3-10S1SBC101037F001405
1SBC101503S0201 ABB MOTOR PROTECTION AND CONTROL 5/77Contact utilization characteristics according to IECContactor relay typesAC operatedNS..SDC operatedNSL..SStandardsIEC 60947-5-1 and EN 60947-5-1Rated operational voltage Ue max.690 VRated frequency (without derating)50 / 60 HzConventional free-air thermal current Ith θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity AC-1510 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device for contactorsUe ≤ 500 V AC - gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aat 40 °C ambient temperature,in free air from a cold statefor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7 Non-overlapping time between N.O. and N.C. contacts1.5 msPower dissipation per pole at 6 A0.1 WMax. electrical switching frequencyAC-151200 cycles/hDC-13900 cycles/hMechanically linked contactsBuilt-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3..S aux. contact blocks) are mechanically linked contacts.acc. to annex L of IEC 60947-5-1Contact utilization characteristics according to UL / CSAContactor relay typesAC operatedNS..SDC operatedNSL..SStandardsUL 508, CSA C22.2 N°14Max. operational voltage600 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VA—NS..S and NSL..S contactor relays - with spring terminalsTechnical data05
1SBC101503S02015/78 ABB MOTOR PROTECTION AND CONTROL—NS..S and NSL..S contactor relays - with spring terminalsTechnical dataMagnet system characteristics for NS..S contactor relaysContactor relay typesAC operatedNS..SCoil operating limits AC supplyacc. to IEC 60947-5-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)AC control voltageRated control circuit voltage Ucat 50 Hz 24...415 Vat 60 Hz 24...415 VCoil consumptionAverage pull-in value50 Hz33 VA60 Hz 33 VA50/60 Hz 33 VAAverage holding value50 Hz 6.5 VA / 1.5 W60 Hz 5 VA / 1.2 W50/60 Hz 6.5 VA / 1.5 WDrop-out voltageApprox. 30...50 % of UcOperating timeBetween coil energization and:N.O. contact closing9...24 msN.C. contact opening6...18 msBetween coil de-energization and:N.O. contact opening (1) 5...19 msN.C. contact closing (1) 7...22 ms(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.Magnet system characteristics for NSL..S contactor relaysContactor relay typesDC operatedNSL..SCoil operating limits DC supplyacc. to IEC 60947-5-10.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)DC control voltageRated control circuit voltage Uc12...240 V DCCoil consumptionAverage pull-in value3 WAverage holding value3 WDrop-out voltageApprox. 10...40 % of UcCoil time constantOpenL/R12 msClosedL/R40 msOperating timeBetween coil energization and:N.O. contact closing36...59 msN.C. contact opening31...53 msBetween coil de-energization and:N.O. contact opening (1) 13...17 msN.C. contact closing (1) 15...20 ms(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2.Mounting characteristics and conditions for useContactor relay typesAC operatedNS..SDC operatedNSL..SMounting positionsPos. 3Pos. 2Pos. 1Pos. 4Pos. 5Mounting distancesThe contactor relays can be assembled side by side.FixingOn rail according to IEC 60715, EN 6071535 x 7.5 mm or 35 x 15 mmBy screws (not supplied)2 x M4 screws placed diagonally05
1SBC101503S0201 ABB MOTOR PROTECTION AND CONTROL 5/79—NS..S and NSL..S contactor relays - with spring terminalsTechnical dataGeneral technical dataContactor relay typesAC operatedNS..SDC operatedNSL..SRated insulation voltage Uiacc. to IEC 60947-5-1690 Vacc. to UL / CSA600 VRated impulse withstand voltage Uimp.6 kVAmbient air temperature close to contactor relayOperation in free air-40...+70 °CStorage-60...+80 °CClimatic withstandCategory B according to IEC 60947-1 Annex QMaximum operating altitude (without derating)3000 mMechanical durabilityNumber of operating cycles20 millions operating cyclesMax. switching frequency3600 cycles/hShock withstand1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open positionacc. to IEC 60068-2-27 and EN 60068-2-27Shock directionMounting position 1NS contactor relays - AC operatedNSL contactor relays - DC operatedA20 g20 g closed position / 10 g open positionB1 5 g15 g closed position / 5 g open positionB2 15 g10 gC1 19 g closed position / 8 g open position19 g closed position / 8 g open positionC2 16 g closed position / 13 g open position14 g closed position / 8 g open positionVibration withstand5...300 Hz3 g closed position / 2 g open positionacc. to IEC 60068-2-6Connecting characteristicsContactor relay typesAC operatedNS..SDC operatedNSL..SMain terminalsSpring terminalsConnection capacity (min. ... max.)Pole and coil terminalsRigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...1.5 mm²2 x 0.75...1.5 mm²Connection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529All terminalsIP20Screwdriver typeFlat Ø 3.5B2AAB1C2C105
1SBC101416S02015/80ABB MOTOR PROTECTION AND CONTROL—NS..S contactor relays - with spring terminalsTerminal marking and positioningA1A21323 33435361 7181NO1424 34NONONONONONONONCNCNCNO445462 7282A1A21321 3143NO1422 32NONCNCNCNCNONO44NS22ESNS53ESA1A21323 33435361 7183NO1424 34NONONONONONONONONCNCNO445462 7284A1A21321 3343NO1422 34NONONONCNCNONO44NS31ESNS62ESA1A21323 33435361 7383NO1424 34NONONONONONONONONONCNO445462 7484A1A21323 3343NO1424 34NONONONONONONO44NS40ESNS71ESA1A21323 33435363 7383NO1424 34NONONONONONONONONONONO445464 7484A1A21323 33435161 7181NO1424 34NONONONONONONONCNCNCNC445262 7282NS44ESNS80ES43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1A243NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1A243NONO4431NCNC3221NCNC2213NONO14A1A243NONO4433NONO3423NONO2413NONO14A1A2NS22ESNS40ESNS71ESNS53ES43NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1A243NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1A233NONO3421NCNC2213NONO1443NONO44A1A243NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1A2NS31ESNS44ESNS80ESNS62ESNS..S contactor relays - AC operatedStandard devices without addition of auxiliary contact blocks-1NC-2-3NO-4-1-2NC-3-4NOCA3-10SCA3-01SCA3..S 1-pole auxiliary contact blocksOther possible contact combinations with auxiliary contact blocks added by the userA1A21321 3343NO1422 34NO44A1A21321 3343NO1422 34NONONONCNCNONONONONCNCNONO44=+-3-4NO5-5-5354NOA1A21323 3343NO1424 34NO44A1A21323 3343NO1424 34NONONONONONONONONONONONONO44=+-3-4NO5-5-5354NOA1A21323 33431424 3444A1A21323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-3-4NO-3-4NO5-5-6-6-5354NO6364NO43NONO4433NONO3423NONO2413NONO1453NONO54A1 A2 43NONO4433NONO3423NONO2413NONO1463NONO6453NONO54A1 A2 A1A21323 33431424 3444A1A21323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-1-2NC-1-2NC5-5-6-6-5152NC6162NC33NONO3421NCNC2213NONO1443NONO4453NONO54A1 A2 43NONO4433NONO3423NONO2413NONO14A1 A2 61NCNC6251NCNC52Combination 50ECombination 60E==NS40ESNS40ESCA3-10SCA3-10SCA3-10S+++Combination 42E=NS40ESCA3-01SCA3-01S++Combination 41E=NS31ESCA3-10S+Combination 50ECombination 60ECombination 41ECombination 42E05
1SBC101416S0201 ABB MOTOR PROTECTION AND CONTROL 5/81—NSL..S contactor relays - with spring terminalsTerminal marking and positioning-3NO-4-3-4NO-1NC-2-1-2NCCA3-10SCA3-01SCA3..S 1-pole auxiliary contact blocksA1+A2-1323 33435361 7181NO1424 34NONONONONONONONCNCNCNO445462 7282A1+A2-1321 3143NO1422 32NONCNCNCNCNONO44NSL53ESNSL22ESA1+A2-1323 33435361 7183NO1424 34NONONONONONONONONCNCNO445462 7284A1+A2-1321 3343NO1422 34NONONONCNCNONO44NSL62ESNSL31ESA1+A2-1323 33435361 7383NO1424 34NONONONONONONONONONCNO445462 7484A1+A2-1323 3343NO1424 34NONONONONONONO44NSL71ESNSL40ESA1+A2-1323 33435363 7383NO1424 34NONONONONONONONONONONO445464 7484A1+A2-1323 33435161 7181NO1424 34NONONONONONONONCNCNCNC445262 7282NSL80ESNSL44ES43NONO4433NONO3423NONO2413NONO1483NONO8471NCNC7261NCNC6253NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7463NONO6453NONO54A1+A2-33NONO3421NCNC2213NONO1443NONO44A1+A2-43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6251NCNC52A1+A2-NSL80ESNSL44ESNSL62ESNSL31ES43NONO4433NONO3423NONO2413NONO1481NCNC8271NCNC7261NCNC6253NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1483NONO8473NONO7461NCNC6253NONO54A1+A2-43NONO4431NCNC3221NCNC2213NONO14A1+A2-43NONO4433NONO3423NONO2413NONO14A1+A2-NSL71ESNSL40ESNSL53ESNSL22ESNSL..S contactor relays - DC operated (the polarity A1+, A2- must be respected)Standard devices without addition of auxiliary contact blocksA1+A2-1321 3343NO1422 34NO44A1+A2-1321 3343NO1422 34NONONONCNCNONONONONCNCNONO44=+-3-4NO5-5-5354NOA1+A2-1323 3343NO1424 34NO44A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONO44=+-3-4NO5-5-5354NOA1+A2-1323 33431424 3444A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-3-4NO-3-4NO5-5-6-6-5354NO6364NO43NONO4433NONO3423NONO2413NONO1453NONO54A1+A2-43NONO4433NONO3423NONO2413NONO1463NONO6453NONO54A1+A2-A1+A2-1323 33431424 3444A1+A2-1323 3343NO1424 34NONONONONONONONONONONONONONONO44=++-1-2NC-1-2NC5-5-6-6-5152NC6162NC33NONO3421NCNC2213NONO1443NONO4453NONO54A1+A2-43NONO4433NONO3423NONO2413NONO14A1+A2-61NCNC6251NCNC52Combination 50ECombination 60E==NSL40ESNSL40ESCA3-10SCA3-10SCA3-10S+++Combination 42E=NS4L0ESCA3-01SCA3-01S++Combination 41E=NSL31ESCA3-10S+Combination 50ECombination 41ECombination 60ECombination 42EOther possible contact combinations with auxiliary contact blocks added by the user05
1SBC101417S02015/82ABB MOTOR PROTECTION AND CONTROL—NS..S contactor relays - with spring terminalsDimensions50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071535.4 1.39"110.8 4.36"ø 4.2 0.17"2 xM4 8-32 UNCNS22ES, NS31ES, NS40ES+ CA3..S front-mounted 1-pole auxiliary contact block50 1.97"60 2.36"35 1.38"72.5 2.85"45 1.77"68 2.68"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNCNS22ES, NS31ES, NS40ES4-pole contactor relays50 1.97"60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"ø 4.2 0.17"2 xM4 8-32 UNCNS44ES, NS53ES, NS62ES, NS71ES, NS80ES8-pole contactor relaysMain dimensions mm, inches05
1SBC101417S0201ABB MOTOR PROTECTION AND CONTROL 5/83—NSL..S contactor relays - with spring terminalsDimensions45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071535.4 1.39"110.8 4.36"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCNSL22ES, NSL31ES, NSL40ES+ CA3..S front-mounted 1-pole auxiliary contact block60 2.36"35 1.38"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715ø 4.2 0.17"2 xM4 8-32 UNCNSL22ES, NSL31ES, NSL40ES4-pole contactor relays45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 60715110.8 4.36"35.4 1.39"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNCNSL44ES, NSL53ES, NSL62ES, NSL71ES, NSL80ES8-pole contactor relaysMain dimensions mm, inches05
1SBC101497S02015/84ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks - with spring terminalsAccessoriesThe auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.CA3 1-pole auxiliary contact blocks, designed for standard industrial environments, are equipped with:•N.O. or N.C. contacts.•spring-type connecting terminals.All 1-pole auxiliary contact blocks are protected against accidental direct contact and bear the corresponding function marking.A maximum of two 1-pole auxiliary contact blocks can be front-mounted on 1-stack contactors or 1-stack contactor relays.For contactorsFor contactor relaysContact blocksType Order codePkg qtyWeight(1 pce) kg1-pole auxiliary contact blocks with spring terminalsAS09..S ... AS16..SNS..S, NSL..S1–CA3-10S1SBN011019T1010100.011ASL09..S ... ASL16..S–1CA3-01S1SBN011019T1001100.011100.39"45 1.77"68 2.68"72.5 2.85"5.5 0.22"7 0.28"35 mm EN/IEC 6071535.4 1.39"110.8 4.36"CA3-10S1SBC101037F0014Main dimensions mm, inches05
1SBC101498S0201 ABB MOTOR PROTECTION AND CONTROL 5/85—Auxiliary contact blocks - with spring terminals Front mountingTechnical dataTy pes1-pole CA3..SContact utilization characteristics according to IECStandardsIEC 60947-5-1 and EN 60947-5-1Rated insulation voltage Ui acc. to IEC 60947-5-1690 VRated impulse withstand voltage Uimp6 kVRated operational voltage Ue max.690 VConventional thermal current Ith - θ ≤ 40 °C10 AIe / Rated operational current AC-15acc. to IEC 60947-5-124-127 V 50/60 Hz 6 A220-240 V 50/60 Hz 4 A400-440 V 50/60 Hz 3 A500 V 50/60 Hz 2 A690 V 50/60 Hz 2 AMaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Breaking capacity10 x Ie AC-15 acc. to IEC 60947-5-1Ie / Rated operational current DC-13acc. to IEC 60947-5-124 V DC 6 A / 144 W48 V DC 2.8 A / 134 W72 V DC 1 A / 72 W110 V DC 0.55 A / 60 W125 V DC 0.55 A / 69 W220 V DC 0.27 A / 60 W250 V DC 0.27 A / 68 WShort-circuit protection device gG type fuse10 ARated short-time withstand current Icwfor 1.0 s 100 Aθ = 40 °Cfor 0.1 s 140 AMinimum switching capacity12 V / 3 mAwith failure rate acc. to IEC 60947-5-410-7Power dissipation per pole at 6 A0.1 WMechanical durabilityNumber of operating cycles10 millions operating cyclesMax. switching frequency3600 cycles/hMax. electrical switching frequencyAC-151200 cycles/hAC-13900 cycles/hMechanically linked contactacc. to annex L of IEC 60947-5-1Additional N.O. or N.C. auxiliary contacts (CA3..S aux. contact blocks) are mechanically linked contactsMirror contactsacc. to annex F of IEC 60947-4-1Additional N.C. auxiliary contacts (CA3..S aux. contact blocks) are mirror contactsContact utilization characteristics according to UL / CSAStandardsUL 508, CSA C22.2 N°14Max. operational voltage690 V AC, 250 V DCPilot dutyA600, Q300AC thermal rated current10 AAC maximum volt-ampere making7200 VAAC maximum volt-ampere breaking720 VADC thermal rated current2.5 ADC maximum volt-ampere making-breaking69 VAConnecting characteristicsConnection capacity (min. ... max.)Rigid solid1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with non insulated ferrule1 x 0.75...2.5 mm²2 x 0.75...2.5 mm²Flexible with insulated ferrule1 x 0.75...1.5 mm²2 x 0.75...1.5 mm²Connection capacity acc. to UL / CSA1 or 2 x AWG 18...14Stripping length10 mmDegree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529IP20Screw terminalsAll terminalsSpring terminalsScrewdriver typeFlat Ø 3.505
1SBC101947S02015/86ABB MOTOR PROTECTION AND CONTROL—Auxiliary contact blocks for AS09..S ... AS16..S, ASL09..S ... ASL16..S contactors and NS, NSL contactor relays - with spring terminalsElectrical durabilityMillions of operating cyclesBreaking current Ic (A)Electrical durability for AC-15 utilization category - Ue ≤ 400 VAC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:•making current: 10 x Ie with cos φ = 0.7 and Ue•breaking current: Ie with cos φ = 0.4 and Ue.This curve represents the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.The curve has been drawn for resistive and inductive loads up to 400 V:•AS09..S ... AS16..S and ASL09..S ... ASL16..S contactor built-in auxiliary contacts•1-pole CA3..S•NS..S and NSL..S contactor relays.Example:Breaking current = 1.3 AOn the opposite curve at intersection "" 1.3 A the corresponding value for the electrical durability is approximately 2 millions operating cycles.0.020.050.10.30.51245100.10.20.30.51235102030360.21.31357905
05 ABB MOTOR PROTECTION AND CONTROL 5/87—Notes
1SBC101499S02015/88ABB MOTOR PROTECTION AND CONTROL—Surge suppressors for contactor coilsAccessoriesThe operation of inductive circuits causes overvoltages, in particular on opening the contactor coil.The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to the breakdown of insulators and even the destruction of certain sensitive components.The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.Following a burst of discharges with a very steep slope, a damped oscillation emerges with a peak value of 3500 V.Overvoltage FactorThe overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil rated control voltage Uc:Ûs max.k = Ûc Ûs max.in DC k = Uc Ûs max.in AC k = Uc √2For example the following is obtained for the above graph: 3500k = ≈ 6042 √2To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppres-sors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies.Each case is different, but the technical data tolerances and generous sizing of parts have enabled us to reduce the number of variants.We have chosen the following solutions: transil diodes, varistors and RC blocks.Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.For contactors For contactor relaysRated control circuit voltage - UcTy pe Order codePkg qtyWeight(1 pce)VDCACkgAS..S, ASL..SNS..S, NSL..S24...50●●RV5/501SBN050010R100020.01550...133●●RV5/1331SBN050010R100120.015110...250●●RV5/2501SBN050010R100220.015250...440●●RV5/4401SBN050010R100320.015AS..SNS..S24...50–●RC5-1/501SBN050100R100020.01250...133–●RC5-1/1331SBN050100R100120.012110...250–●RC5-1/2501SBN050100R100220.012250...440–●RC5-1/4401SBN050100R100320.012ASL..SNSL..S12...32●–RT5/321SBN050020R100020.01525...65●–RT5/651SBN050020R100120.01550...90●–RT5/901SBN050020R100220.01577...150●–RT5/1501SBN050020R100320.015150...264●–RT5/2641SBN050020R100420.01501000100 (V)T (μs)01000100RV51SBC101042F0014RT51SBC101042F0014RC5-11SBC101042F001472.5 2.85"45 1.77"68 2.68"45 1.77"68 2.68"72.5 2.85"45 1.77"68 2.68"45 1.77"68 2.68"Easy connection to the coil terminals (parallel mounting)Clip-on for both fixing and connection.No additional spaceClipped onto the right side part of the contactor base without changing con-tactor overall dimensions and keeping a free access to coil terminals.Main dimensions mm, inches05
1SBC101602S0201 ABB MOTOR PROTECTION AND CONTROL 5/89—Surge suppressors for contactor coilsTechnical dataVaristorRV5/50RV5/133RV5/250RV5/4 4 0Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V AC24...50 V DC50...133 V DC110...250 V DC250...440 V DCResidual overvoltage (clipping voltage)132 V AC 270 V AC480 V AC825 V AC132 V DC 270 V DC480 V DC825 V DCOpening time growth factornoneOperating temperature-20...+70 °CAdvantagesHigh energy absorption: good damping - Unpolarized system.DrawbackClipping as from Uvdr*, thus voltage front up to this point.*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %.RC typeRC5-1/50RC5-1/133RC5-1/250RC5-1/440Rated control circuit voltage Uc24...50 V AC50...133 V AC110...250 V AC250...440 V ACResidual overvoltage (clipping voltage)2 to 3 x Uc max.Opening time growth factor2...3Operating temperature-20...+70 °CAdvantagesVery fast clipping - Attenuation of steep fronts and thus of high frequencies.Transil diodeRT5/32RT5/65RT5/90RT5/150RT5/264Rated control circuit voltage Uc12...32 V DC25...65 V DC50...90 V DC77...150 V DC150...264 V DCResidual overvoltage (clipping voltage)50 V DC100 V DC150 V DC210 V DC390 V DCOpening time growth factor1.1...1.2Operating temperature-20...+70 °CAdvantagesGood energy absorption - Unpolarized system - Simple, reliable system.DrawbackDelay on drop out which does not however reduce contactor breaking capacity.Wiring diagramsA1A2E0733DA1A2E0735DA1A2E0734DTransil diodeVaristorRC type05
1SBC101782S02015/90ABB MOTOR PROTECTION AND CONTROLBEA16-3U1SBC101384F0010—Connecting links for starting solutions and other accessories Connecting linksThe BEA16-3U insulated connecting links are used to connect an AS..S AC operated contactor or an ASL..S DC operated contactor with a manual motor starter.The connecting link ensure the electrical and mechanical connection between the contactor and the manual motor starter.For contactorsManual motor starterType Order codePkg qtyWeight(1 pce)kgAS09..S ... AS16..S ASL09..S ... ASL16..SMS116-0.16 ... MS116-16 MS132-0.16 ... MS132-16BEA16-3U1SBN081020R100010.045Test blockBDT4 test block is suitable for switching on contactor off-load. Marking on the block indicates the contactor type to fit with.For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAS..S, ASL..S, NS..S, NSL..SBDT41SBN110122T1000100.007Function markersBox of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking table to identify your contactors, overload relays or manual motor starters. Marker dimensions: 7 x 20 mm (.276" x .787").For contactors Ty pe Order codePkg qtyWeight(1 pce)kgAS..S, ASL..S, NS..S, NSL..SBA41SNA235156R2700160.011AMS 500 support plate for 8 BA4SPRC 11SNA360010R150010.220HTP500 support plateHTP500-BA41SNA235712R240010.2901SBC100043V0014B DT4BA41SNC160101F001405
1SBC101621S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 5/91—Voltage code tableThe below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give either type or order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the type or in the order code according to the table below. Example: for contactor AS09-30-10S and coil 42 V 50/60 Hz, type is AS09-30-10S-21 and order code is 1SBL101004R2110.Auxiliary contacts N.O. N.C.N.O. N.C. Main contactsTypeOrder codeContactor typeAS16 - 30 -10S -26AS AC operatedASL DC operatedAC coil code 50 Hz 60 Hz20 24 V 24 V21 42 V 42 V22 48 V 48 V23 110 V 110 V24 115 V 115 V16 – 120 V25 220 V 220 V26 230 V 230 V27 240 V 240 V17 – 277 V13 380 V –28 400 V 400 V29 415 V 415 V1SBL121004R2610DC coil code80 12 V81 24 V83 48 V84 60 V86 110 V87 125 V88 220 V89 240 V3-pole contactors - with spring terminalsContactor relays - with spring terminalsContactor with spring terminalN.O. N.C. Number contacts TypeOrder codeNS 40 ES -26Contactor typeNS AC operatedNSL DC operatedAC coil code 50 Hz 60 Hz20 24 V 24 V21 42 V 42 V22 48 V 48 V23 110 V 110 V24 115 V 115 V16 – 120 V25 220 V 220 V26 230 V 230 V27 240 V 240 V17 – 277 V13 380 V –28 400 V 400 V29 415 V 415 V1SBH101004R2640DC coil code80 12 V81 24 V83 48 V84 60 V86 110 V87 125 V88 220 V89 240 VContactor with spring terminal05
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/T16-1.3 www.abb.com/productdetails/1SAZ711201R1025or
—Overload relays6/2 Overview Thermal overload relays6/4 T16 thermal overload relays – 0.10 to 16.0 A6/8 TF42 thermal overload relays – 0.10 to 38.0 A6/13 TF65 thermal overload relays – 22.0 to 67.0 A6/17 TF96 thermal overload relays – 40.0 to 96.0 A6/21 TF140DU thermal overload relays – 66 to 142 A6/25 TA200DU thermal overload relays – 66 to 200 A Electronic overload relays6/29 E16DU, EF19, EF45 electronic overload relays – 0.10 to 45.0 A6/33 EF65, EF96, EF146 electronic overload relays – 20 to 150 A6/37 EF205, EF370 electronic overload relays – 63 to 380 A6/41 EF460, EF750, EF1250DU electronic overload relays 150 to 1250 A6/44 General accessories ABB MOTOR PROTECTION AND CONTROL 6/106
6/2ABB MOTOR PROTECTION AND CONTROL—Thermal and electronic overload relaysThermal overload relaysIEC: rated operational power AC-3400 V 0.06 ... 7.5 kW0.06 ... 7.5 kW0.06 ... 18.5 kW11 ... 37 kW18.5 ... 45 kW37 ... 75 kW37 ... 110 kWUL/CSA: 3-phase hp-ratings480 V 1/2 ... 10 hp1/2 ... 10 hp1/2 ... 25 hp15 ... 50 hp30 ... 75 hp50 ... 100 hp50 ... 150 hpFitting to contactorsB6, B7AS09 ... AS16AF09 ... AF38AF40, AF52, AF65AF80, AF96AF116, AF140, AF146AF190, AF205Ty p eT16T16TF42TF65TF96TF140DUTA200DUCurrent range0.10 ... 16 A0.10 ... 16 A0.10 ... 38 A22 ... 67 A40 ... 96 A66 ... 142 A66 ... 200 ATrip class101010101010A10ASingle mounting kitDB16DB16DB42DB65DB96-DB200Electronic overload relayswith integrated CTIEC: rated operational power AC-3400 V 0.06 ... 7.5 kW0.06 ... 7.5 kW4 ... 22 kW7.5 ... 37 kW22 ... 55 kW30 ... 75 kW37 ... 110 kW75 ... 200 kWUL/CSA: 3-phase hp-ratings480 V 1/2 ... 10 hp1/2 ... 10 hp5 ... 30 hp15 ... 50 hp30 ... 75 hp50 ... 100 hp50 ... 150 hp100 ... 300 hpFitting to contactorsB6, B7, BC6, BC7, VB6, VB7, VBC6, VBC7AF09 ... AF38AF26 ... AF38AF40, AF52, AF65AF80, AF96AF116, AF140, AF146AF190, AF205AF265, AF305, AF370Ty p eE16DUEF19EF45EF65EF96EF146EF205EF370Current range0.10 ... 18.9 A0.10 ... 18.9 A9 ... 45 A20 ... 70 A36 ... 100 A54 ... 150 A63 ... 210 A115 ... 380 ATrip class10E, 20E, 30E selectable10E, 20E, 30E selectableSingle mounting kitDB16EDB19EFDB45EF-DB96---Electronic overload relayswith external separate CTIEC: rated operational power AC-3400 V 75 ... 250 kW132 ... 400 kW250 ... 710 kWUL/CSA: 3-phase hp-ratings480 V 100 ... 400 hp200 ... 500 hp600 ... 900 hpFitting to contactorsAF400, AF460AF580, AF750, AF1250AF1350, AF1650, AF2050Ty p eEF460EF750EF1250DUCurrent range150 ... 500 A250 ... 800 A375 ... 1250 ATrip class10E, 20E, 30E selectable06
ABB MOTOR PROTECTION AND CONTROL 6/3Thermal overload relaysIEC: rated operational power AC-3400 V 0.06 ... 7.5 kW0.06 ... 7.5 kW0.06 ... 18.5 kW11 ... 37 kW18.5 ... 45 kW37 ... 75 kW37 ... 110 kWUL/CSA: 3-phase hp-ratings480 V 1/2 ... 10 hp1/2 ... 10 hp1/2 ... 25 hp15 ... 50 hp30 ... 75 hp50 ... 100 hp50 ... 150 hpFitting to contactorsB6, B7AS09 ... AS16AF09 ... AF38AF40, AF52, AF65AF80, AF96AF116, AF140, AF146AF190, AF205Ty p eT16T16TF42TF65TF96TF140DUTA200DUCurrent range0.10 ... 16 A0.10 ... 16 A0.10 ... 38 A22 ... 67 A40 ... 96 A66 ... 142 A66 ... 200 ATrip class101010101010A10ASingle mounting kitDB16DB16DB42DB65DB96-DB200Electronic overload relayswith integrated CTIEC: rated operational power AC-3400 V 0.06 ... 7.5 kW0.06 ... 7.5 kW4 ... 22 kW7.5 ... 37 kW22 ... 55 kW30 ... 75 kW37 ... 110 kW75 ... 200 kWUL/CSA: 3-phase hp-ratings480 V 1/2 ... 10 hp1/2 ... 10 hp5 ... 30 hp15 ... 50 hp30 ... 75 hp50 ... 100 hp50 ... 150 hp100 ... 300 hpFitting to contactorsB6, B7, BC6, BC7, VB6, VB7, VBC6, VBC7AF09 ... AF38AF26 ... AF38AF40, AF52, AF65AF80, AF96AF116, AF140, AF146AF190, AF205AF265, AF305, AF370Ty p eE16DUEF19EF45EF65EF96EF146EF205EF370Current range0.10 ... 18.9 A0.10 ... 18.9 A9 ... 45 A20 ... 70 A36 ... 100 A54 ... 150 A63 ... 210 A115 ... 380 ATrip class10E, 20E, 30E selectable10E, 20E, 30E selectableSingle mounting kitDB16EDB19EFDB45EF-DB96---Electronic overload relayswith external separate CTIEC: rated operational power AC-3400 V 75 ... 250 kW132 ... 400 kW250 ... 710 kWUL/CSA: 3-phase hp-ratings480 V 100 ... 400 hp200 ... 500 hp600 ... 900 hpFitting to contactorsAF400, AF460AF580, AF750, AF1250AF1350, AF1650, AF2050Ty p eEF460EF750EF1250DUCurrent range150 ... 500 A250 ... 800 A375 ... 1250 ATrip class10E, 20E, 30E selectable—Single mounting kit overviewD816 + T16D842 + TF42D865 + TF65D896 + TF96DB200 + TA200EOLD819EFD819EF + EF19D845EF + EF45D896 + EF96020406080100120140160180200 ATOLD816D842D865D896D8200D845EFD89606
2CDC106036C02016/4ABB MOTOR PROTECTION AND CONTROL—T16 thermal overload relays – 0.10 to 16.0 AOrdering detailsThe T16 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). •Manual or automatic reset selectable •Phase loss sensitive acc. to IEC/EN 60947-4-1 •TEST and STOP function – Trip indication on the front •Temperature compensation •Suitable for three- and single-phase applicationsSetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AS09...AS16, B6 and B7 all variants0.10 ... 0.130.5 A, fuse type T10T16-0.131SAZ711201R10050.1000.13 ... 0.171.0 A, fuse type T10T16-0.171SAZ711201R10080.1000.17 ... 0.231.0 A, fuse type T10T16-0.231SAZ711201R10090.1000.23 ... 0.311.0 A, fuse type T10T16-0.311SAZ711201R10130.1000.31 ... 0.412.0 A, fuse type gG10T16-0.411SAZ711201R10140.1000.41 ... 0.552.0 A, fuse type gG10T16-0.551SAZ711201R10170.1000.55 ... 0.744.0 A, fuse type gG10T16-0.741SAZ711201R10210.1000.74 ... 1.006.0 A, fuse type gG10T16-1.01SAZ711201R10230.1001.00 ... 1.306.0 A, fuse type gG10T16-1.31SAZ711201R10250.1001.30 ... 1.7010.0 A, fuse type gG10T16-1.71SAZ711201R10280.1001.70 ... 2.3010.0 A, fuse type gG10T16-2.31SAZ711201R10310.1002.30 ... 3.1010.0 A, fuse type gG10T16-3.11SAZ711201R10330.1003.10 ... 4.2020.0 A, fuse type gG10T16-4.21SAZ711201R10350.1004.20 ... 5.7020.0 A, fuse type gG10T16-5.71SAZ711201R10380.1005.70 ... 7.6035.0 A, fuse type gG10T16-7.61SAZ711201R10400.1007.60 ... 10.035.0 A, fuse type gG10T16-101SAZ711201R10430.10410.0 ... 13.040.0 A, fuse type gG10T16-131SAZ711201R10450.10413.0 ... 16.040.0 A, fuse type gG10T16-161SAZ711201R10470.104Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitT16DB161SAZ701901R00010.032Reset push buttonE16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.0272CDC231009F0013T162CDC231025F0013T16 + DB1635.6 1.4"48.2 1.9"36.9 1.45"2.4 0.09"53.5 2.11"1.2 0.05"9.1 0.36"8.6 0.34"76.7 3.02"45 1.77"8.1 0.32"14.4 0.57"12.35 0.49"9.1 0.36"2CDC232008F0008T162CDC231002F0011DB161SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC106036C0201 ABB MOTOR PROTECTION AND CONTROL 6/5Main circuit – Utilization characteristics according to IEC/ENTypeT16StandardsIEC/EN 60947–4–1, IEC/EN 60947-5-1, IEC/EN 60947-1Rated operational voltage Ue690 V AC- V DCRated frequency50/60 HzTrip class10Number of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V ACAuxiliary circuit according to IEC/ENTypeT16Rated operational voltage Ue600 VConventional free air thermal current IthN.C., 95-96 6 AN.O., 97-98 4 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A220-230-240 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A440 VN.C., 95-96 0.75 AN.O., 97-98 0.75 A480-500 VN.C., 95-96 0.75 AN.O., 97-98 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A60 VN.C., 95-96 0.55 AN.O., 97-98 0.55 A110-120-125 VN.C., 95-96 0.55 AN.O., 97-98 0.55 A250 VN.C., 95-96 0.27 AN.O., 97-98 0.27 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 6 A, fuse type gGN.O., 97-98 4 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time—T16 thermal overload relays – 0.10 to 16.0 ATechnical data06
2CDC106036C02016/6ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to UL/CSATypeT16StandardsUL 508, CSA 22.2 No. 14Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeT16Contact ratingN.C., 95-96 B600, Q300N.O., 97-98D300, Q300Conventional thermal currentN.C., 95-96 5 AN.O., 97-98 2.5 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V AC480 / 600 V ACShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalFuse typeT16-0.130.13 A18 kA1 A, K5100 kA30 A, Class JT16-0.170.17 A18 kA1 A, K5100 kA30 A, Class JT16-0.230.23 A18 kA1 A, K5100 kA30 A, Class JT16-0.310.31 A18 kA3 A, K5100 kA30 A, Class JT16-0.410.41 A18 kA3 A, K5100 kA30 A, Class JT16-0.550.55 A18 kA3 A, K5100 kA30 A, Class JT16-0.740.74 A18 kA3 A, K5100 kA30 A, Class JT16-1.01.00 A18 kA6 A, K5100 kA30 A, Class JT16-1.31.30 A18 kA6 A, K5100 kA30 A, Class JT16-1.71.70 A18 kA6 A, K5100 kA30 A, Class JT16-2.32.30 A18 kA10 A, K5100 kA30 A, Class JT16-3.13.10 A18 kA10 A, K5100 kA30 A, Class JT16-4.24.20 A18 kA15 A, K5100 kA30 A, Class JT16-5.75.70 A18 kA20 A, K5100 kA30 A, Class JT16-7.67.60 A18 kA25 A, K5100 kA30 A, Class JT16-1010.0 A18 kA35 A, K5100 kA45 A, Class JT16-1313.0 A18 kA40 A, K5100 kA45 A, Class JT16-1616.0 A18 kA60 A, K5100 kA45 A, Class J—T16 thermal overload relays – 0.10 to 16.0 ATechnical data06
2CDC106036C0201 ABB MOTOR PROTECTION AND CONTROL 6/7General technical dataTypeT16Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +60 °COpen-25 ... +60 °CStorage-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-63g / 3 ... 150 HzMounting positionPosition 1-5MountingMount on the contactor and tighten the screws of the main circuit terminals or with single mounting kit on DIN rail (35 mm)Degree of protectionHousingIP20Main circuit terminalsIP10Electrical connectionMain circuitTypeT16Connecting capacityRigid1 x2 x0.75 ... 4 mm² 0.75 ... 1.5 mm² or 1.5 ... 4 mm² (1)Flexible1 x or 2 x 0.75 ... 4 mm²Stranded acc. to UL/CSA1 x or 2 x AWG 18-10Flexible acc. to UL/CSA1 x or 2 x AWG 18-10Stripping length12 mmTightening torque1.1 ... 1.5 Nm / 9 ... 13 Ib.in Recommended screw driverM4 (Pozidriv 2)Auxiliary circuitTypeT16Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x2 x0.75 ... 2.5 mm²0.75 ... 1.5 mm²Flexible1 x or 2 x 0.75 ... 1 mm² or 1 ... 2.5 mm² (1)Stranded acc. to UL/CSA1 x or 2 x AWG 18-12Flexible acc. to UL/CSA1 x or 2 x AWG 18-12Stripping length9 mmTightening torque1.1 ... 1.5 Nm / 9 ... 13 Ib.inRecommended screw driverM3 (Pozidriv 2)(1) Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges—T16 thermal overload relays – 0.10 to 16.0 ATechnical data06
2CDC106046C02016/8ABB MOTOR PROTECTION AND CONTROL—TF42 thermal overload relays – 0.10 to 38.0 AOrdering detailsThe TF42 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). •Manual or automatic reset selectable •Phase loss sensitive acc. to IEC/EN 60947-4-1 •TEST and STOP function – Trip indication on the front •Temperature compensation •Suitable for three- and single-phase applications•With ATEX certificationSetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF09...AF38 contactors0.10 ... 0.130.5 A, fuse type T10TF42-0.131SAZ721201R10050.1300.13 ... 0.171.0 A, fuse type T10TF42-0.171SAZ721201R10080.1300.17 ... 0.231.0 A, fuse type T10TF42-0.231SAZ721201R10090.1300.23 ... 0.311.0 A, fuse type T10TF42-0.311SAZ721201R10130.1300.31 ... 0.412.0 A, fuse type gG10TF42-0.411SAZ721201R10140.1300.41 ... 0.552.0 A, fuse type gG10TF42-0.551SAZ721201R10170.1300.55 ... 0.744.0 A, fuse type gG10TF42-0.741SAZ721201R10210.1300.74 ... 1.006.0 A, fuse type gG10TF42-1.01SAZ721201R10230.1301.00 ... 1.306.0 A, fuse type gG10TF42-1.31SAZ721201R10250.1301.30 ... 1.7010.0 A, fuse type gG10TF42-1.71SAZ721201R10280.1301.70 ... 2.3010.0 A, fuse type gG10TF42-2.31SAZ721201R10310.1302.30 ... 3.1010.0 A, fuse type gG10TF42-3.11SAZ721201R10330.1303.10 ... 4.2020.0 A, fuse type gG10TF42-4.21SAZ721201R10350.1304.20 ... 5.7020.0 A, fuse type gG10TF42-5.71SAZ721201R10380.1305.70 ... 7.6035.0 A, fuse type gG10TF42-7.61SAZ721201R10400.1307.60 ... 10.035.0 A, fuse type gG10TF42-101SAZ721201R10430.13010.0 ... 13.040.0 A, fuse type gG10TF42-131SAZ721201R10450.13013.0 ... 16.040.0 A, fuse type gG10TF42-161SAZ721201R10470.13016.0 ... 20.063.0 A, fuse type gG10TF42-201SAZ721201R10490.14520.0 ... 24.063.0 A, fuse type gG10TF42-241SAZ721201R10510.14524.0 ... 29.063.0 A, fuse type gG10TF42-291SAZ721201R10520.14529.0 ... 35.080.0 A, fuse type gG10TF42-351SAZ721201R10530.14535.0 ... 38.0/40.0 80.0 A, fuse type gG10TF42-381SAZ721201R10550.1452CDC231006F0013TF422CDC231026F0013TF42 + DB422.3 0.09"88.3 3.48"12.35 0.49"9.1 0.36"14.4 0.57"8.1 0.32"45 1.77"16.2 0.64"11.7 0.46"50.25 1.98"2.7 0.11"52.6 2.07"70.5 2.78"66.4 2.61"2CDC232005F0009TF42Main dimensions mm, inches06
2CDC106046C0201 ABB MOTOR PROTECTION AND CONTROL 6/9—TF42 thermal overload relays – 0.10 to 38.0 AOrdering detailsOrdering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitTF42DB421SAZ701902R00010.087Reset push buttonE16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.019Remote reset coil 24-30 V AC/DCTF42, TF65, TF96DRS-F-011SAX101911R10010.077Remote reset coil 48-60 V AC/DCDRS-F-021SAX101911R10020.077Remote reset coil 110-127 V AC/DCDRS-F-031SAX101911R10030.077Remote reset coil 220-240 V AC/DCDRS-F-041SAX101911R10040.0771SFC151224F0002 KPR-101L2CDC231001F0011DB4206
2CDC106046C02016/10ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTy peTF42StandardsIEC/EN 60947–4–1, IEC/EN 60947-5-1, IEC/EN 60947-1Rated operational voltage Ue690 V ACRated frequency50/60 HzTrip class10Number of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V ACAuxiliary circuit according to IEC/ENTypeTF42Rated operational voltage Ue600 VConventional free air thermal current IthN.C., 95-96 6 AN.O., 97-98 4 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A220-230-240 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A440 VN.C., 95-96 0.75 AN.O., 97-98 0.75 A480-500 VN.C., 95-96 0.75 AN.O., 97-98 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A110-120-125 VN.C., 95-96 0.55 AN.O., 97-98 0.55 A250 VN.C., 95-96 0.27 AN.O., 97-98 0.27 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 6 A, fuse type gGN.O., 97-98 4 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time—TF42 thermal overload relays – 0.10 to 38.0 ATechnical data06
2CDC106046C0201 ABB MOTOR PROTECTION AND CONTROL 6/11Main circuit – Utilization characteristics according to UL/CSATypeTF42StandardsUL 508, CSA 22.2 No. 14Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeTF42Contact ratingN.C., 95-96 B600, Q300N.O., 97-98D300, Q300Conventional thermal currentN.C., 95-96 5 AN.O., 97-98 2.5 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V AC480 / 600 V ACShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalFuse typeTF42-0.130.13 A18 kA1 A, K5100 kA30 A, Class JTF42-0.170.17 A18 kA1 A, K5100 kA30 A, Class JTF42-0.230.23 A18 kA1 A, K5100 kA30 A, Class JTF42-0.310.31 A18 kA3 A, K5100 kA30 A, Class JTF42-0.410.41 A18 kA3 A, K5100 kA30 A, Class JTF42-0.550.55 A18 kA3 A, K5100 kA30 A, Class JTF42-0.740.74 A18 kA3 A, K5100 kA30 A, Class JTF42-1.01.00 A18 kA6 A, K5100 kA30 A, Class JTF42-1.31.30 A18 kA6 A, K5100 kA30 A, Class JTF42-1.71.70 A18 kA6 A, K5100 kA30 A, Class JTF42-2.32.30 A18 kA10 A, K5100 kA30 A, Class JTF42-3.13.10 A18 kA10 A, K5100 kA30 A, Class JTF42-4.24.20 A18 kA15 A, K5100 kA30 A, Class JTF42-5.75.70 A18 kA20 A, K5100 kA30 A, Class JTF42-7.67.60 A18 kA25 A, K5100 kA30 A, Class JTF42-1010.0 A18 kA35 A, K5100 kA45 A, Class JTF42-1313.0 A18 kA40 A, K5100 kA45 A, Class JTF42-1616.0 A18 kA60 A, K5100 kA45 A, Class JTF42-2020.0 A18 kA80 A, K5100 kA60 A, Class JTF42-2424.0 A18 kA80 A, K5100 kA60 A, Class JTF42-2929.0 A18 kA100 A, K5100 kA100 A, Class JTF42-3535.0 A18 kA150 A, K5100 kA175 A, Class JTF42-3838.0 A18 kA150 A, K5100 kA175 A, Class J—TF42 thermal overload relays – 0.10 to 38.0 ATechnical data06
2CDC106046C02016/12ABB MOTOR PROTECTION AND CONTROLGeneral technical dataTypeTF42Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +60 °COpen-25 ... +60 °CStorage-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-63g / 3 ... 150 HzMounting positionPosition 1-5MountingMount on the contactor and tighten the screws of the main circuit terminals or with single mounting kit on DIN rail (35 mm)Degree of protectionHousingIP20Main circuit terminalsIP10Electrical connectionMain circuitTypeTF42(TF42-0.13 ... TF42-16)TF42(TF42-20 ... TF42-38)Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²1.5 ... 2.5 mm² or 2.5 ... 10 mm² (1)Flexible with insulated ferrule1 x or 2 x 0.75 ... 4 mm²2.5 ... 4 mm² or 4 ... 6 mm² (1)Stranded acc. to UL/CSA1 x or 2 x AWG 18-10AWG 14-6Flexible acc. to UL/CSA1 x or 2 x AWG 18-10AWG 14-6Stripping length12 mmTightening torque1.5 - 2.5 Nm / 13 ... 22 Ib.in2.5 - 2.7 Nm / 22 Ib.inRecommended screw driverM4 (Pozidriv 2)Auxiliary circuitTypeTF42Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x2 x0.75 ... 2.5 mm²0.75 ... 1.5 mm²Flexible1 x or 2 x 0.75 ... 1 mm² or 1 ... 2.5 mm² (1)Stranded acc. to UL/CSA1 x or 2 x AWG 18-12Flexible acc. to UL/CSA1 x or 2 x AWG 18-12Stripping length9 mmTightening torque1.1 ... 1.5 Nm / 9 ... 13 Ib.inRecommended screw driverM3 (Pozidriv 2)(1) Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges.—TF42 thermal overload relays – 0.10 to 38.0 ATechnical data06
2CDC106063C0201 ABB MOTOR PROTECTION AND CONTROL 6/13—TF65 thermal overload relays – 22.0 to 67.0 AOrdering detailsThe TF65 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). • Manual or automatic reset selectable • Phase loss sensitive acc. to IEC/EN 60947-4-1 • TEST and STOP function – Trip indication on the front • Temperature compensation • Suitable for three- and single-phase applications• With ATEX certification (1)Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF40...AF65 contactors22.0 ... 28.080 A, gG Type Fuses10TF65-281SAZ811201R10010.45625.0 ... 33.080 A, gG Type Fuses10TF65-331SAZ811201R10020.45630.0 ... 40.0100 A, gG Type Fuses10TF65-401SAZ811201R10030.45636.0 ... 47.0125 A, gG Type Fuses10TF65-471SAZ811201R10040.45644.0 ... 53.0 125 A, gG Type Fuses10TF65-531SAZ811201R10050.45650.0 ... 60.0125 A, gG Type Fuses10TF65-601SAZ811201R10060.46657.0 ... 67.0160 A, gG Type Fuses10TF65-671SAZ811201R10070.466Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitTF65DB651SAZ801901R10010.132Reset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.019Remote reset coil 24-30 V AC / DCTF42, TF65, TF96DRS-F-011SAX101911R10010.077Remote reset coil 48-60 V AC / DCDRS-F-021SAX101911R10020.077Remote reset coil 110-127 V AC / DCDRS-F-031SAX101911R10030.077Remote reset coil 220-240 V AC / DCDRS-F-041SAX101911R10040.0771) ATEX is valid for products, produced from week 26, 2015.2CDC231004F0013TF652CDC231003V0015DB652CDC231004V0015DB65 + TF652T14T26T316.6 0.65"7 0.28"34.8 1.37"67.8 2.67"87.7 3.45"46 1.81"54.9 2.16"37.4 1.47"10.4 0.41"18.9 0.74"4 0.08"55.7 2.19"10.1 0.40"65 2.56"83.5 3.29"102.8 4.05"106.1 4.18"106.9 4.21"101.4 3.45"2CDC232005F0009TF651SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC106063C02016/14ABB MOTOR PROTECTION AND CONTROL—TF65 thermal overload relays – 22.0 to 67.0 ATechnical dataMain circuit – Utilization characteristics according to IEC/ENTypeTF65StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue690 V ACRated frequency50/60 HzTrip class10Number of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui690 VAuxiliary circuit according to IEC/ENTypeTF65Rated operational voltage Ue600 VConventional free air thermal current IthN.C., 95-96 6 AN.O., 97-98 4 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A220-230-240 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A440 VN.C., 95-96 0.75 AN.O., 97-98 0.75 A480-500 VN.C., 95-96 0.75 AN.O., 97-98 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A110-120-125 VN.C., 95-96 0.55 AN.O., 97-98 0.55 A250 VN.C., 95-96 0.27 AN.O., 97-98 0.27 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 6 A, gG Type FusesN.O., 97-98 4 A, gG Type FusesRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time06
2CDC106063C0201 ABB MOTOR PROTECTION AND CONTROL 6/15—TF65 thermal overload relays – 22.0 to 67.0 ATechnical dataMain circuit – Utilization characteristics according to UL/CSATypeTF65StandardsUL 60947-1, UL 60947-4-1Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeTF65Contact ratingN.C., 95-96 B600, Q600N.O., 97-98 D300, Q600Conventional thermal currentN.C., 95-96 6 AN.O., 97-98 4 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V AC480 / 600 V ACShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalFuse typeTF65-2828 A5 kA100 A, K5 / RK5100 kA110 A, Class JTF65-3333 A5 kA100 A, K5 / RK5100 kA110 A, Class JTF65-4040 A5 kA100 A, K5 / RK5100 kA110 A, Class JTF65-4747 A5 kA125 A, K5 / RK5100 kA125 A, Class JTF65-5353 A10 kA125 A, K5 / RK5100 kA125 A, Class JTF65-6060 A10 kA150 A, K5 / RK5100 kA150 A, Class JTF65-6767 A10 kA150 A, K5 / RK5100 kA150 A, Class J06
2CDC106063C02016/16ABB MOTOR PROTECTION AND CONTROL—TF65 thermal overload relays – 22.0 to 67.0 ATechnical dataGeneral technical dataTypeTF65Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperation (1)Open - compensated-40 ... +70 °C Open-40 ... +70 °CStorage-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN 60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzMounting positionPosition 1 to 6MountingMount on the contactor and tighten the screws of the main circuit terminals or with single mounting kit on DIN rail (35 mm)Degree of protectionHousingIP20Main circuit terminalsIP10(1) Valid for TF65 produced from week 11, 2016. Otherwise, -25 ...+60 °C range is valid. Derating might be applicable for temperatures > 50°C. Data on requestElectrical connectionMain circuitTypeTF65Connecting capacityRigid1 x or 2 x1 x2.5 ... 16 mm²2.5 ... 35 mm²Flexible with ferrule1 x or 2 x1 x2.5 ... 10 mm²2.5 ... 35 mm²Flexible with insulated ferrule1 x or 2 x1 x2.5 ... 10 mm²2.5 ... 35 mm²Flexible1 x or 2 x1 x2.5 ... 16 mm²2.5 ... 35 mm²Stranded acc. to UL/CSA1 x2 xAWG 12 ... 2AWG 12 ... 6Flexible acc. to UL/CSA1 x2 xAWG 12 ... 2AWG 12 ... 6Stripping length17 mmTightening torque4.0 - 4.5 Nm / 35 ... 40 Ib.inRecommended screw driverM6 (Pozidriv 2)Auxiliary circuitTypeTF65Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 4 mm²Flexible with insulated ferrule1 x2 x0.75 ... 2.5 mm²0.75 ... 1.5 mm²Flexible1 x or 2 x 0.75 ... 1 mm² or 1 ... 2.5 mm²Stranded acc. to UL/CSA1 x or 2 x AWG 18 ... 12Flexible acc. to UL/CSA1 x or 2 x AWG 18 ... 12Stripping length9 mmTightening torque1.1 ... 1.5 Nm / 9 ... 13 Ib.inRecommended screw driverM3 (Pozidriv 2)06
2CDC106064C0201 ABB MOTOR PROTECTION AND CONTROL 6/17—TF96 thermal overload relays – 40.0 to 96.0 AOrdering detailsThe TF96 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). • Manual or automatic reset selectable • Phase loss sensitive acc. to IEC/EN 60947-4-1 • TEST and STOP function – Trip indication on the front • Temperature compensation • Suitable for three- and single-phase applications• With ATEX certification (1)Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF80, AF96 contactors40.0 ... 51.0125 A, gG Type Fuses10TF96-511SAZ911201R10010.62048.0 ... 60.0160 A, gG Type Fuses10TF96-601SAZ911201R10020.62057.0 ... 68.0160 A, gG Type Fuses10TF96-681SAZ911201R10030.62065.0 ... 78.0200 A, gG Type Fuses10TF96-781SAZ911201R10040.62075.0 ... 87.0200 A, gG Type Fuses10TF96-871SAZ911201R10050.62084.0 ... 96.0250 A, gG Type Fuses10TF96-961SAZ911201R10060.630Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitTF96, EF96DB961SAZ901901R10010.190Reset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.019Remote reset coil 24-30 V AC/DCTF42, TF65, TF96DRS-F-011SAX101911R10010.077Remote reset coil 48-60 V AC/DCDRS-F-021SAX101911R10020.077Remote reset coil 110-127 V AC/DCDRS-F-031SAX101911R10030.077Remote reset coil 220-240 V AC/DCDRS-F-041SAX101911R10040.077(1) ATEX is valid for products, produced from week 26, 2015.2CDC231005F0013TF962CDC231001V0015DB962CDC231005V0015DB96 + TF962T14T26T316.6 0.65"10 0.39"45.8 1.80"70.3 2.77"60.6 3.57"46 1.81"44.9 1.77"54.9 2.16"17.9 0.70"18.9 0.74"2.5 0.10"58.5 2.30"12.1 0.47"67.5 2.66"83.5 3.29"102.8 4.05"106.1 4.18"106.9 4.21"106.3 4.19"69.9 2.75"2CDC232005F0009TF961SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC106064C02016/18ABB MOTOR PROTECTION AND CONTROL—TF96 thermal overload relays – 40.0 to 96.0 ATechnical dataMain circuit – Utilization characteristics according to IEC/ENTypeTF96StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue690 V ACRated frequency50/60 HzTrip class10Number of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui690 VAuxiliary circuit according to IEC/ENTypeTF96Rated operational voltage Ue600 VConventional free air thermal current IthN.C., 95-96 6 AN.O., 97-98 4 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A220-230-240 VN.C., 95-96 3.00 AN.O., 97-98 0.75 A440 VN.C., 95-96 0.75 AN.O., 97-98 0.75 A480-500 VN.C., 95-96 0.75 AN.O., 97-98 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A110-120-125 VN.C., 95-96 0.55 AN.O., 97-98 0.55 A250 VN.C., 95-96 0.27 AN.O., 97-98 0.27 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 6 A, fuse type gGN.O., 97-98 4 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time06
2CDC106064C0201 ABB MOTOR PROTECTION AND CONTROL 6/19—TF96 thermal overload relays – 40.0 to 96.0 ATechnical dataMain circuit – Utilization characteristics according to UL/CSATypeTF96StandardsUL 60947-1, UL 60947-4-1Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeTF96Contact ratingN.C., 95-96 B600, Q600N.O., 97-98 D300, Q600Conventional thermal currentN.C., 95-96 6 AN.O., 97-98 4 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V AC480 / 600 V ACShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalFuse typeTF96-5151 A5 kA150 A, K5 / RK5100 kA125 A, Class JTF96-6060 A10 kA150 A, K5 / RK5100 kA150 A, Class JTF96-6868 A10 kA150 A, K5 / RK5100 kA150 A, Class JTF96-7878 A10 kA175 A, K5 / RK5100 kA175 A, Class JTF96-8787 A10 kA200 A, K5 / RK5100 kA200 A, Class JTF96-9696 A10 kA250 A, K5 / RK5100 kA200 A, Class J06
2CDC106064C02016/20ABB MOTOR PROTECTION AND CONTROL—TF96 thermal overload relays – 40.0 to 96.0 ATechnical dataGeneral technical dataTypeTF96Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperation (1)Open - compensated-40 ... +70 °COpen-40 ... +70 °CStorage-50 ... +80 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzMounting positionPosition 1 to 6MountingMount on the contactor and tighten the screws of the main circuit terminals or with single mounting kit on DIN rail (35 mm)Degree of protectionHousingIP20Main circuit terminalsIP10(1) Valid for TF96 produced from week 11, 2016. Otherwise, -25 ...+60 °C range is valid. Derating might be applicable for temperatures > 50°C. Data on request.Electrical connectionMain circuitTypeTF96Connecting capacityRigid1 x or 2 x1 x6 ... 35 mm²6 ... 50 mm²Flexible with ferrule1 x or 2 x1 x6 ... 35 mm²6 ... 50 mm²Flexible with insulated ferrule1 x or 2 x1 x6 ... 16 mm²6 ... 50 mm²Flexible1 x or 2 x1 x6 ... 35 mm²6 ... 50 mm²Stranded acc. to UL/CSA1 x2 xAWG 8 ... 1AWG 8 ... 3Flexible acc. to UL/CSA1 x2 xAWG 8 ... 1AWG 8 ... 3Stripping length20 mm (1)Tightening torque6 ... 9 Nm / 53 ... 80 Ib.in (2)Recommended screw driverM8 (Hexagon)(2) Valid for products, produced from week 27, 2015Auxiliary circuitTypeTF96Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 4 mm²Flexible with insulated ferrule1 x2 x0.75 ... 2.5 mm²0.75 ... 1.5 mm²Flexible1 x or 2 x 0.75 ... 1 mm² or 1 ... 2.5 mm² Stranded acc. to UL/CSA1 x or 2 x AWG 18 ...12Flexible acc. to UL/CSA1 x or 2 x AWG 18 ... 12Stripping length9 mmTightening torque1.1 ... 1.5 Nm / 9 ... 13 Ib.inRecommended screw driverM3 (Pozidriv 2)06
2CDC106054C0201 ABB MOTOR PROTECTION AND CONTROL 6/21—TF140DU thermal overload relays – 66 to 142 AOrdering detailsThe TF140DU thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10A.The thermal overload relays are three pole relays with bimetal tripping elements. The motor cur-rent flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a re-lease of the relay and a change of the contacts switching position (95-96 / 97-98). • Manual or automatic reset selectable • Phase loss sensitive acc. to IEC/EN 60947-4-1 • TEST and STOP function – Trip indication on the front • Temperature compensation • Suitable for three- and single-phase applications• ATEX variants availableSetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF116...AF140 contactors66 ... 90200 A, fuse type gG10ATF140DU-901SAZ431201R10010.82080 ... 110224 A, fuse type gG10ATF140DU-1101SAZ431201R10020.820100 ... 135224 A, fuse type gG10ATF140DU-1351SAZ431201R10030.820110 ... 142250 A, fuse type gG10ATF140DU-1421SAZ431201R10040.82066 ... 90200 A, fuse type gG10ATF140DU-90-V1000*1SAZ431301R10010.82080 ... 110224 A, fuse type gG10ATF140DU-110-V1000*1SAZ431301R10020.820100 ... 135224 A, fuse type gG10ATF140DU-135-V1000*1SAZ431301R10030.820110 ... 142250 A, fuse type gG10ATF140DU-142-V1000*1SAZ431301R10040.820*Note: ATEX variantOrdering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgReset push buttonE16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.0272CDC231012F0012TF140DU989796952/T14/T26/T3140 5.51"25 0.98"58.82.31"13.450.53"89 3.5"29.75 1.17"6.4 3.5"73.8 2.91"126 4.96"6 0.24"4 0.16"19.9 0.78"5.5 0.22"37 1.46"67.3 2.65"82.3 3.24" 5.3 0.21"501.97"68 2.68"80 3.15"84.2 3.31"51 2.01"29.75 1.17"25 0.98"8 0.31"2CDC232008F0012TF140DU1SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC106054C02016/22ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeTF140DU / TF140DU-V1000StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue690 V ACRated frequencyDC, 50/60 HzFrequency range0 ... 400 HzTrip class10ANumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui690 VAuxiliary circuit according to IEC/ENTypeTF140DU / TF140DU-V1000Rated operational voltage Ue500 V AC, 440 V DCConventional free air thermal current IthN.C., 95-96 10 AN.O., 97-98 6 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 1.50 A220-230-240 VN.C., 95-96 1.50 AN.O., 97-98 1.50 A440 VN.C., 95-96 1.00 AN.O., 97-98 1.00 A480-500 VN.C., 95-96 1.00 AN.O., 97-98 1.00 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A60 VN.C., 95-96 0.25 AN.O., 97-98 0.25 A110-120-125 VN.C., 95-96 0.25 AN.O., 97-98 0.25 A250 VN.C., 95-96 0.12 AN.O., 97-98 0.04 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 10 A, fuse type gGN.O., 97-98 6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time—TF140DU thermal overload relays – 66 to 142 ATechnical data06
2CDC106054C0201 ABB MOTOR PROTECTION AND CONTROL 6/23Main circuit – Utilization characteristics according to UL/CSATypeTF140DU / TF140DU-V1000StandardsUL 508, CSA 22.2 No. 14, UL 60947-4-1AMaximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeTF140DU / TF140DU-V1000Contact ratingN.C., 95-96B600N.O., 97-98C300Conventional thermal currentN.C./N.O.10 A / 6 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V AC480 / 600 V AC480 / 600 V ACShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalListed circuit breakerTF140DU-90 / TF140DU-90-V1000 90 A10 kA250 A, K5 / RK5100 kA250 A, Class J100 kA250 ATF140DU-110 / TF140DU-110-V1000 110 A10 kA250 A, K5 / RK5100 kA250 A, Class J100 kA250 ATF140DU-135 / TF140DU-135-V1000 135 A10 kA250 A, K5 / RK5100 kA250 A, Class J100 kA250 ATF140DU-142 / TF140DU-142-V1000 142 A10 kA250 A, K5 / RK5100 kA250 A, Class J100 kA250 A—TF140DU thermal overload relays – 66 to 142 ATechnical data06
2CDC106054C02016/24ABB MOTOR PROTECTION AND CONTROLGeneral technical dataTypeTF140DU / TF140DU-V1000Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +55 °COpen-25 ... +55 °CStorage-40 ... +70 °CAmbient air temperature compensationAcc. to IEC/EN 60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2712g / 11 msMounting positionPosition 1-5MountingMount on the contactor and tighten the screws of the main circuit terminalsDegree of protectionHousingIP20Main circuit terminalsIP00Electrical connectionMain circuitTypeTF140DU / TF140DU-V1000Connecting capacityRigid1 x2 x16 ... 70 mm² -Flexible1 x2 x16 ... 70 mm² -Stranded acc. to UL/CSA1 x or 2 x AWG 6-2/0Flexible acc. to UL/CSA1 x or 2 x AWG 6-2/0Stripping length25 mmTightening torque8 ... 10 Nm / 77 ... 88 Ib.in Recommended screw driverM8 (Hexagon)Auxiliary circuitTypeTF140DU / TF140DU-V1000Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible1 x or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 x or 2 x AWG 18-14Flexible acc. to UL/CSA1 x or 2 x AWG 18-14Stripping length9 mmTightening torque0.8 ... 1.3 Nm / 12 Ib.inRecommended screw driverM3.5 (Pozidriv 2)—TF140DU thermal overload relays – 66 to 142 ATechnical data06
2CDC106038C0201 ABB MOTOR PROTECTION AND CONTROL 6/25—TA200DU thermal overload relays – 66 to 200 AOrdering detailsThe TA200DU thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10A.The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). • Manual or automatic reset selectable • Phase loss sensitive acc. to IEC/EN 60947-4-1 • TEST and STOP function – Trip indication on the front • Temperature compensation • Suitable for three- and single-phase applications• ATEX variants availableSetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF145...AF2050 contactors66 ... 90200 A, fuse type gG / 125 A aM10ATA200DU-901SAZ421201R10010.75580 ... 110224 A, fuse type gG / 160 A aM10ATA200DU-1101SAZ421201R10020.760100 ... 135224 A, fuse type gG / 200 A aM10ATA200DU-1351SAZ421201R10030.760110 ... 150250 A, fuse type gG / 200 A aM10ATA200DU-1501SAZ421201R10040.760130 ... 175315 A, fuse type gG / 250 A aM10ATA200DU-1751SAZ421201R10050.770150 ... 200315 A, fuse type gG / 250 A aM10ATA200DU-2001SAZ421201R10060.78566 ... 90 200 A, fuse type gG / 125 A aM10ATA200DU-90-V1000 (1)1SAZ421301R1001 0.75580 ... 110 224 A, fuse type gG / 160 A aM10ATA200DU-110-V1000 (1) 1SAZ421301R1002 0.760100 ... 135 224 A, fuse type gG / 200 A aM10ATA200DU-135-V1000 (1) 1SAZ421301R1003 0.760110 ... 150 250 A, fuse type gG / 200 A aM10ATA200DU-150-V1000 (1) 1SAZ421301R1004 0.760130 ... 175 315 A, fuse type gG / 250 A aM10ATA200DU-175-V1000 (1) 1SAZ421301R1005 0.770150 ... 200 315 A, fuse type gG / 250 A aM 10ATA200DU-200-V1000 (1)1SAZ421301R10060.785(1) ATEX variantOrdering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgTerminal shroudTA200DULT200/A1SAZ401901R10010.090Single mounting kitTA200DUDB2001SAZ401110R00010.225Reset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.0272CDC231016F0013TA200DU4 0.16"61 2.4"8 0.31"126 4.96"6 0.24"4 0.16"6 0.24"32 1.26"3 0.12"23 0.91"26 1.02"37 1.46"35 1.38"35 1.38"Ø8.5 Ø0.33"5.5 0.22"82.3 3.24"11 0.43"30.9 1.22"49.9 2"151 5.94"10 0.39"68 2.68"80 3.15"Ø 11 Ø 0.43"20 0.79"22.1 0.87"Ø 5.3 Ø 0.21"42 1.65"42 1.65"50 1.97"2CDC232021F0011TA200DU1SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC106038C02016/26ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeTA200DU / TA200DU-V1000StandardsIEC/EN 60947-1, IEC/EN 60947-4-1Rated operational voltage Ue690 V ACRated frequencyDC, 50/60 HzFrequency range0 ... 400 HzTrip class10ANumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V ACAuxiliary circuit according to IEC/ENTypeTA200DU / TA200DU-V1000Rated operational voltage Ue500 V AC, 440 V DCConventional free air thermal current IthN.C., 95-96 10 AN.O., 97-98 6 ARated frequencyDC, 50/60 HzNumber of poles1 N.O. + 1 N.C.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 VN.C., 95-96 3.00 AN.O., 97-98 1.50 A220-230-240 VN.C., 95-96 3.00 AN.O., 97-98 1.50 A440 VN.C., 95-96 1.00 AN.O., 97-98 1.00 A480-500 VN.C., 95-96 1.00 AN.O., 97-98 1.00 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 VN.C., 95-96 1.25 AN.O., 97-98 1.25 A60 VN.C., 95-96 0.25 AN.O., 97-98 0.25 A110-120-125 VN.C., 95-96 0.25 AN.O., 97-98 0.25 A250 VN.C., 95-96 0.12 AN.O., 97-98 0.04 AMinimum switching capacity17 V / 3 mAShort-circuit protective deviceN.C., 95-96 10 A, fuse type gGN.O., 97-98 6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232004F0214ta: Motor starting time—TA200DU thermal overload relays – 66 to 200 ATechnical data06
2CDC106038C0201 ABB MOTOR PROTECTION AND CONTROL 6/27Main circuit – Utilization characteristics according to UL/CSATypeTA200DU / TA200DU-V1000StandardsUL 508, CSA 22.2 No. 14Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeTA200DU / TA200DU-V1000Contact ratingN.C., 95-96C600N.O., 97-98B600Conventional thermal current5 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 / 600 V ACShort circuit rating RMS symmetricalFuse typeListed circuit breakerShort circuit rating RMS symmetricalFuse typeShort circuit rating RMS symmetricalListed circuit breakerTA200DU-90 / TA200DU-90-V100090 A10 kA250 A, K5 / RK5225 A100 kA250 A, Class J100 kA250 ATA200DU-110 / TA200DU-110-V1000110 A10 kA250 A, K5 / RK5225 A100 kA250 A, Class J100 kA250 ATA200DU-135 / TA200DU-135-V1000135 A10 kA300 A, K5 / RK5225 A100 kA250 A, Class J100 kA250 ATA200DU-150 / TA200DU-150-V1000150 A10 kA300 A, K5 / RK5225 A100 kA250 A, Class J100 kA250 ATA200DU-175 / TA200DU-175-V1000175 A10 kA300 A, K5 / RK5225 A100 kA300 A, Class J100 kA300 ATA200DU-200 / TA200DU-200-V1000200 A10 kA400 A, K5 / RK5400 A100 kA400 A, Class J100 kA400 A—TA200DU thermal overload relays – 66 to 200 ATechnical data06
2CDC106038C02016/28ABB MOTOR PROTECTION AND CONTROLGeneral technical dataTypeTA200DU / TA200DU-V1000Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +55 °COpen-25 ... +55 °CStorage-40 ... +70 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2712g / 15 msMounting positionPosition 1-6MountingMount on the contactor and tighten the screws of the main circuit terminals or with single mounting kitDegree of protectionHousingIP20Main circuit terminalsIP00Electrical connectionMain circuitTypeTA200DU / TA200DU-V1000Connecting capacityRigid1 x 25 ... 120 mm²Flexible1 x 25 ... 120 mm²Stranded acc. to UL/CSA1 x AWG 4 ... 0000Flexible acc. to UL/CSA1 x AWG 4 ... 0000LugsL > 10 mmTightening torque25 Nm / 220 lb.inRecommended screwdriverOpen barsAuxiliary circuitTypeTA200DU / TA200DU-V1000Connecting capacityRigid1 x or 2 x 0.75 ... 4 mm²Flexible with ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 x or 2 x 0.75 ... 2.5 mm²Flexible1 x or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 x or 2 x AWG 18 ... 14Flexible acc. to UL/CSA1 x or 2 x AWG 18 ... 14Stripping length9 mmTightening torque0.8 ... 1.3 Nm / 12 Ib.inRecommended screwdriverM3.5 (Pozidriv 2)—TA200DU thermal overload relays – 66 to 200 ATechnical data06
2CDC107032C0201 ABB MOTOR PROTECTION AND CONTROL 6/29—E16DU, EF19, EF45 electronic overload relays – 0.10 to 45.0 AOrdering detailsThe E16DU, EF19 and EF45 are self-supplied electronic overload relays, which means no extra external supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to the contactors. The EF19 and EF45 have ATEX and IECEx certification (1).Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgE16DU electronic overload relays, suitable for B6 & B70.10 ... 0.321 A, fuse type gG10E, 20E, 30EE16DU-0.321SAX111001R11010.1500.30 ... 1.004 A, fuse type gG10E, 20E, 30EE16DU-1.01SAX111001R11020.1500.80 ... 2.7010 A, fuse type gG10E, 20E, 30EE16DU-2.71SAX111001R11030.1502.00 ... 6.3020 A, fuse type gG10E, 20E, 30EE16DU-6.31SAX111001R11040.1505.70 ... 18.950 A, fuse type gG10E, 20E, 30EE16DU-18.91SAX111001R11050.150EF19 electronic overload relays, suitable for AF09 ... AF26 (1)0.10 ... 0.321 A, fuse type gG10E, 20E, 30EEF19-0.321SAX121001R11010.1580.30 ... 1.004 A, fuse type gG10E, 20E, 30EEF19-1.01SAX121001R11020.1580.80 ... 2.7010 A, fuse type gG10E, 20E, 30EEF19-2.71SAX121001R11030.1581.90 ... 6.3020 A, fuse type gG10E, 20E, 30EEF19-6.31SAX121001R11040.1585.70 ... 18.950 A, fuse type gG10E, 20E, 30EEF19-18.91SAX121001R11050.158EF45 electronic overload relays, suitable for AF26 ... AF38 (1)9.00 ... 30.0160 A, fuse type gG10E, 20E, 30EEF45-301SAX221001R11010.36215.0 ... 45.0160 A, fuse type gG10E, 20E, 30EEF45-451SAX221001R11020.362(1) ATEX is valid for products produced from week 42, 2014. IECEx is valid for products produced from week 15, 2017.Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitE16DUDB16E1SAX101110R00010.035Single mounting kitEF19DB19EF1SAX101910R10010.046Single mounting kitEF45DB45EF1SAX201910R00010.100Reset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.019 2CDC231001F0007E16DU-1.0 1SBC101147F0010EF19-18.9 1SBC101148F0010EF45-30 2CDC231024V0013 DB19EF 2CDC231002V0014 DB45EF37.536.32.4 74.6 5.65 10.3 8.2 14 44.4 9.3 9.3 1.2 5753 1.48”1.43”0.37” 2.94” 0.22”0.41” 0.32” 0.55” 1.75” 0.37” 0.37”0.5” 2.24” 2.09”85 3.35"55.42.18"59.3 2.33"14 0.55"15.73 0.62"38.8 1.53"1.2 0.05"11.78 0.46"5.65 0.22"8.2 0.32"37.5 1.48"10.3 0.41"2.3 0.09"44.4 1.75"E16DUEF19, EF451SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC107032C02016/30ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeE16DUEF19EF45StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue690 V ACRated frequency50/60 Hz – not suitable for DC applicationsTrip class10E, 20E, 30E, selectableNumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V ACAuxiliary circuit according to IEC/ENTypeE16DUEF19EF45Rated operational voltage Ue600 V AC / DCConventional free air thermal current Ith6 ARated frequencyDC, 50/60 HzNumber of poles1 N.C. + 1 N.O.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 V50/60 Hz 3.00 A220-230-240 V50/60 Hz 3.00 A440 V50/60 Hz 1.10 A480-500 V50/60 Hz 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 V1.50 A60 V0.55 A110-120-125 V0.55 A250 V0.27 AMinimum switching capacity12 V / 3 mAShort-circuit protective devices6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 V—E16DU, EF19, EF45 electronic overload relays – 0.10 to 45.0 ATechnical data104.7 4.12"82.13.23"86 3.39"14 0.55"14 0.55"59.5 2.34"2 0.08"14 0.55"5.65 0.22"8.5 0.33"56.5 2.22"10.3 0.41"3.4 0.13"45 1.77"EF4506
2CDC107032C0201 ABB MOTOR PROTECTION AND CONTROL 6/31Technical diagram – Intermittent periodic dutyduty ratio (Op/h)switching frequency Trip class 10E (%)0 20 40 60 80 100 120 140 160 0 20406080100t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232001F0214duty ratio (Op/h)switching frequency Trip class 20E (%)0 10 20 30 40 50 60 70 80 0 20406080100t = 4 sat = 8 sat = 10 sat = 12 sat = 2 sat = 6 sa2CDC232002F0214duty ratio (Op/h)switching frequency Trip class 30E (%)0 5 10 15 20 25 30 35 45 0 2040608010040 50 t = 10 sat = 20 sat = 25 sat = 5 sat = 15 sa2CDC232003F0214Trip class 10ETrip class 20ETrip class 30EMain circuit – Utilization characteristics according to UL/CSATypeE16DUEF19EF45StandardsUL 508, CSA 22.2 No. 14Maximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeE16DUEF19EF45Contact ratingN.C., 95-96 B600, Q300B600, Q600N.O., 97-98 B600, Q300B600, Q600Conventional free-air thermal current6 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 V AC600 V ACSCCRFuse typeSCCRFuse typeSCCRFuse typeE16DU-0.320.32 A50 kA2 A, Class J5 kA2 A, K5 / RK5100 kA2 A, Class JE16DU-1.01.00 A50 kA2 A, K5 / RK55 kA2 A, K5 / RK5100 kA2 A, Class JE16DU-2.72.70 A50 kA4 A, K5 / RK55 kA4 A, K5 / RK5100 kA4 A, Class JE16DU-6.36.30 A50 kA15 A, K5 / RK55 kA15 A, K5 / RK5100 kA15 A, Class JE16DU-18.918.90 A50 kA30 A, K5 / RK55 kA30 A, K5 / RK5100 kA30 A, Class JTy peFull load amps (FLA)Short-circuit protective device480 V AC600 V ACSCCRFuse typeSCCRFuse typeSCCRFuse typeEF19-0.320.32 A50 kA2 A, Class J5 kA2 A, K5 / RK5100 kA2 A, Class JEF19-1.01.00 A50 kA2 A, K5 / RK55 kA2 A, K5 / RK5100 kA2 A, Class JEF19-2.72.70 A50 kA4 A, K5 / RK55 kA4 A, K5 / RK5100 kA4 A, Class JEF19-6.36.30 A50 kA15 A, K5 / RK55 kA15 A, K5 / RK5100 kA15 A, Class JEF19-18.918.90 A50 kA30 A, K5 / RK55 kA30 A, K5 / RK5100 kA30 A, Class JTy peFull load amps (FLA)Short-circuit protective device480 V AC600 V ACSCCRFuse typeSCCRFuse typeSCCRFuse typeEF45-3030 A18 kA150 A, K5 / RK518 kA150 A, K5 / RK5100 kA150 A, Class JEF45-4545 A18 kA200 A, K5 / RK518 kA200 A, K5 / RK5100 kA200 A, Class J—E16DU, EF19, EF45 electronic overload relays – 0.10 to 45.0 ATechnical data06
2CDC107032C02016/32ABB MOTOR PROTECTION AND CONTROLGeneral dataTypeE16DUEF19EF45Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +70 °CStorage-50 ... +85 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2715g / 11 ms pulse25g / 11 ms pulseResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz3g / 3 ... 150 HzMounting positionPosition 1-6MountingMount on the contactor and tighten the screws of the main circuit terminalsDegree of protectionHousingIP20Main circuit terminalsIP20Electrical connectionMain circuitTypeE16DUEF19EF45Connecting capacityRigid1 or 2 x 1 ... 4 mm²1 ... 4 mm²2.5 ... 16 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 2.5 mm²2.5 ... 10 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-10AWG 16-10AWG 14-6Flexible acc. to UL/CSA1 or 2 x AWG 16-10AWG 16-10AWG 14-6Stripping length9 mm9 mm13 mmTightening torque0.8 ... 1.5 Nm / 7 ... 13 Ib.in0.8 ... 1.5 Nm / 7 ... 13 Ib.in2.3 ... 2.6 Nm / 20 ... 22 Ib.inRecommended screw driverM3.5 (Pozidriv 2)M3.5 (Pozidriv 2)M3.5 (Pozidriv 2)Auxiliary circuitTypeE16DUEF19EF45Connecting capacityRigid1 or 2 x 1 ... 4 mm²1 ... 4 mm²1 ... 4 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 2.5 mm²0.75 ... 2.5 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²0.75 ... 2.5 mm²0.75 ... 2.5 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²0.75 ... 2.5 mm²0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 or 2 x AWG 16-10AWG 18-10AWG 18-10Flexible acc. to UL/CSA1 or 2 x AWG 16-10AWG 18-10AWG 18-10Stripping length9 mm9 mm9 mmTightening torque0.8 ... 1.2 Nm / 7 ... 11 Ib.in0.8 ... 1.2 Nm / 7 ... 11 Ib.in0.8 ... 1.2 Nm / 7 ... 11 Ib.inRecommended screw driverM3 (Pozidriv 2)M3 (Pozidriv 2)M3 (Pozidriv 2)—E16DU, EF19, EF45 electronic overload relays – 0.10 to 45.0 ATechnical data06
2CDC107038C0201 ABB MOTOR PROTECTION AND CONTROL 6/33—EF65, EF96, EF146 electronic overload relays – 20 to 150 AOrdering detailsThe EF65, EF96 and EF146 are self-supplied electronic overload relays, which means no extra ex-ternal supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Fur-ther features are the temperature compensation, trip contact (N.C.), signal contact (N.O.), auto-matic or manual reset selectable, trip-free mechanism, STOP and TEST function and a trip indica-tion. The overload relays are connected directly to the contactors. The EF65, EF96 and EF146 have ATEX and IECEx certification (1).Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF40, AF52, AF6520 ... 56160 A, fuse type gG10E, 20E, 30EEF65-561SAX331001R11020.82125 ... 70160 A, fuse type gG10E, 20E, 30EEF65-701SAX331001R11010.821Suitable for AF80, AF9620 ... 56160A, fuse type gG10E, 20E, 30EEF96-561SAX341001R11020.80236 ... 100200 A, fuse type gG 10E, 20E, 30EEF96-1001SAX341001R11010.802Suitable for AF116, AF140, AF14654 ... 150315 A, fuse type gG10E, 20E, 30EEF146-1501SAX351001R11010.879(1) ATEX is valid for products produced from week 42, 2014. ATEX certification is valid for EF65-56 produced from week 47, 2015. IECEx is valid for products produced from week 15, 2017.Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgSingle mounting kitEF96, TF96DB961SAZ901901R10010.190Reset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.019 2CDC231001F0012EF65-70 2CDC231002F0012EF96-100 2CDC231003F0012EF146-150 2CDC231001V0015DB96 2CDC231002V0015DB96 + EF9658 16 37 70 5.5 53.3 3 17.2 0.39"103.2 1"11 3 74 101.4105.274.2 85.2 105.2 120.238.434.65 55 8 2.28"0.63"1.46"2.76"0.22"2.1"0.12"0.68"10 4.06"25.4 0.43"0.12"2.91" 3.99"4.14"2.92"3.35"4.14"4.73"1.51"1.36"2.17"0.31"58 5.5 16 37 70 8 43.7 38.4 74.2 85.2 105.2 121.7 56.6 3 17.2 105.2 74 101.4 3 11 10 103.2 25.4 2.28"0.22"0.63"1.46"2.76"0.31"1.72"1.51"2.92"3.35"4.14"4.79"2.23"0.12"0.68"4.14"2.91"3.99"0.12"0.43"0.39"4.06"1"EF65-56 / EF65-70EF96-56 / EF96-10089.05 3.51"60.1 2.37"13 0.5"6.6 0.26"5.5 0.22"139.4 5.49"15.5 0.61"4 0.16"3 0.12"74 2.91"101.4 3.99"105.2 4.14"70 2.76"58 2.28"37 1.46"16 0.63"127 5"117.4 4.62"38.4 1.51"74.2 2.92"85.2 3.35"88.9 3.5"103.7 4.08"11 0.43"10 0.39"119.25 4.69"EF146-1501SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC107038C02016/34ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeEF65, EF96, EF146StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue1000 V ACRated frequency50/60 Hz – not suitable for DC applicationsTrip class10E, 20E, 30E, selectableNumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui1000 VAuxiliary circuit according to IEC/ENTypeEF65, EF96, EF146Rated operational voltage Ue600 V AC / DCConventional free air thermal current Ith6 ARated frequencyDC, 50/60 HzNumber of poles1 N.C. + 1 N.O.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 V50/60 Hz 3.00 A220-230-240 V50/60 Hz 3.00 A400 V50/60 Hz 1.10 A480-500 V50/60 Hz 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 V1.50 A60 V0.55 A110-120-125 V0.55 A250 V0.27 AMinimum switching capacity12 V / 3 mAShort-circuit protective device6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratio (Op/h)switching frequency Trip class 10E (%)0 20 40 60 80 100 120 140 160 0 20406080100t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232001F0214duty ratio (Op/h)switching frequency Trip class 20E (%)0 10 20 30 40 50 60 70 80 0 20406080100t = 4 sat = 8 sat = 10 sat = 12 sat = 2 sat = 6 sa2CDC232002F0214duty ratio (Op/h)switching frequency Trip class 30E (%)0 5 10 15 20 25 30 35 45 0 2040608010040 50 t = 10 sat = 20 sat = 25 sat = 5 sat = 15 sa2CDC232003F0214Trip class 10ETrip class 20ETrip class 30E—EF65, EF96, EF146 electronic overload relays – 20 to 150 ATechnical data06
2CDC107038C0201 ABB MOTOR PROTECTION AND CONTROL 6/35Main circuit – Utilization characteristics according to UL/CSATypeEF65, EF96, EF146StandardsUL 508, CSA 22.2 No. 14, UL 60947-4-1AMaximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeEF65, EF96, EF146Contact ratingN.C., 95-96 B600, Q600N.O., 97-98 B600, Q600Conventional thermal current6 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 V AC600 V ACSCCRFuse typeSCCRFuse typeSCCRFuse typeEF65-5656 A10 kA150 A, K5/RK510 kA150 A, K5/RK5100 kA150 A, JEF65-7070 A10 kA150 A, K5/RK510 kA150 A, K5/RK5100 kA150 A, JEF96-6556 A10 kA150 A, K5/RK510 kA150 A, K5/RK5100 kA150 A, JEF96-100100 A10 kA200 A, K5/RK510 kA200 A, K5/RK5100 kA225 A, JEF146-150150 A10 kA250 A, K5/RK510 kA250 A, K5/RK5100 kA350 A, J—EF65, EF96, EF146 electronic overload relays – 20 to 150 ATechnical data06
2CDC107038C02016/36ABB MOTOR PROTECTION AND CONTROLGeneral dataTypeEF65, EF96, EF146Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +70 °CStorage-50 ... +85 °CAmbient air temperature compensationAcc. to IEC/EN 60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2715g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzMounting positionPosition 1-6MountingMount on the contactor and tighten the screws of the main circuit terminalsDegree of protectionHousingIP20Main circuit terminalsIP10Electrical connectionMain circuitTypeEF65EF96EF146Connecting capacityRigid (1)1 x2 x4 ... 35 mm²4 ... 35 mm²4 ... 70 mm²4 ... 35 mm²10 ... 95 mm²10 ... 35 mm²Flexible (1)1 x2 x4 ... 35 mm²2.5 ... 35 mm²4 ... 50 mm²4 ... 35 mm²10 ... 70 mm²10 ... 35 mm²Stranded acc. to UL/CSA1 x2 xAWG 10-2AWG 10-2AWG 6-00AWG 6-2Flexible acc. to UL/CSA1 x2 xAWG 10-2AWG 10-2AWG 6-00AWG 6-2Stripping length20 mm20 mm20 mmTightening torque4 Nm / 35 lb.in6 Nm / 55 lb.in10 Nm / 70 lb.inRecommended screw driverM8 (Pozidriv 2)M8 (Hexagon 4)M8 (Hexagon 4)(1) Only one wire size allowed when using 2 wiresAuxiliary circuitTypeEF65, EF96, EF146Connecting capacityRigid1 or 2 x 1 ... 4 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 or 2 x AWG 18-10Flexible acc. to UL/CSA1 or 2 x AWG 18-10Stripping length9 mmTightening torque0.8 ... 1.2 Nm / 7 ... 11 Ib.inRecommended screw driverM3.5 (Pozidriv 2)—EF65, EF96, EF146 electronic overload relays – 20 to 150 ATechnical data06
2CDC107040C0201 ABB MOTOR PROTECTION AND CONTROL 6/37—EF205, EF370 electronic overload relays – 63 to 380 AOrdering detailsThe EF205 and EF370 are self-supplied electronic overload relays, which means no extra external supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to the contactors. The EF205 and EF370 have ATEX and IECEx certification (1).Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgSuitable for AF145, AF185, AF190, AF20563 ... 2101250 A, fuse type gG 10E, 20E, 30EEF205-2101SAX531001R11011.210Suitable for AF210, AF260, AF265, AF300, AF305, AF370115 ... 3801600 A, fuse type gG 10E, 20E, 30EEF370-3801SAX611001R11011.430(1) ATEX is valid for products produced from week 42, 2015. IECEx is valid for products produced from week 15, 2017.Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgReset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.027Terminal shroudEF205LT200E1SAX501904R00010.085Terminal shroudEF370LT320E1SAX601904R00010.105 2CDC231010V0012EF205-210 2CDC231013V0012EF370-380105 7.4 17.9 18.5 5 11 122 151 10 17.5 35 Ø 8.5 10 30 5 116.5 122.8 5 35 121.7 35 4.13"0.29"0.7"0.73"0.2"0.43"4.8"5.9"0.39"1.18"0.2"4.59"4.83"0.69"1.38"Ø 0.33"0.39"1.38"0.2"1.38"4.79"EF205-210122.8 4.83"30 1.18"116.5 4.59"5 0.2"35 1.38"50.2"121.7 4.79"14 0.55"163.6 6.4"10 0.39"22.8 0.9"93.8 3.69"7.4 0.29"105 4.13"17.9 0.7"20 0.79"43.8 1.72"43.8 1.72"Ø 11 Ø 0.43"11 0.43"122 0.4'5 0.2"EF370-3801SFC151224F0002 KPR-101LMain dimensions mm, inches06
2CDC107040C02016/38ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeEF205, EF370StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue1000 V ACRated frequency50/60 Hz – not suitable for DC applicationsTrip class10E, 20E, 30E, selectableNumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui1000 VAuxiliary circuit according to IEC/ENTypeEF205, EF370Rated operational voltage Ue600 V AC / DCConventional free air thermal current Ith6 ARated frequencyDC, 50/60 HzNumber of poles1 N.C. + 1 N.O.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 V50/60 Hz 3.00 A220-230-240 V50/60 Hz 3.00 A400 V50/60 Hz 1.10 A480-500 V50/60 Hz 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 V1.50 A60 V0.55 A110-120-125 V0.55 A250 V0.27 AMinimum switching capacity12 V / 3 mAShort-circuit protective device6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratio (Op/h)switching frequency Trip class 10E (%)0 20 40 60 80 100 120 140 160 0 20406080100t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232001F0214duty ratio (Op/h)switching frequency Trip class 20E (%)0 10 20 30 40 50 60 70 80 0 20406080100t = 4 sat = 8 sat = 10 sat = 12 sat = 2 sat = 6 sa2CDC232002F0214duty ratio (Op/h)switching frequency Trip class 30E (%)0 5 10 15 20 25 30 35 45 0 2040608010040 50 t = 10 sat = 20 sat = 25 sat = 5 sat = 15 sa2CDC232003F0214Trip class 10ETrip class 20ETrip class 30E—EF205, EF370 electronic overload relays – 63 to 380 ATechnical data06
2CDC107040C0201 ABB MOTOR PROTECTION AND CONTROL 6/39Main circuit – Utilization characteristics according to UL/CSATypeEF205, EF370StandardsUL 508, CSA 22.2 No. 14, UL 60947-4-1AMaximum operational voltage600 V ACTrip rating125% of FLAFull load amps (FLA)See table "Full load amps and short-circuit protective device"Short-circuit rating RMS symmetricalSee table "Full load amps and short-circuit protective device"Short-circuit protective deviceSee table "Full load amps and short-circuit protective device"Auxiliary circuit according to UL/CSATypeEF205, EF370Contact ratingN.C., 95-96 B600, Q600N.O., 97-98 B600, Q600Conventional thermal current6 AFull load amps and short-circuit protective deviceTy peFull load amps (FLA)Short-circuit protective device480 V AC600 V ACSCCRFuse typeSCCRFuse typeSCCRFuse typeEF205-210210 A10 kA400 A, R5/RK510kA400 A, R5/RK5100 kA400 A, JEF370-380380 A18 kA800 A, L/T18kA800 A, L/T--—EF205, EF370 electronic overload relays – 63 to 380 ATechnical data06
2CDC107040C02016/4 0ABB MOTOR PROTECTION AND CONTROLGeneral dataTypeEF205EF370Pollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +70 °CStorage-50 ... +85 °CAmbient air temperature compensationAcc. to IEC/EN 60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-65g / 3 ... 150 HzMounting positionPosition 1-6MountingMount on the contactor and tighten the screws of the main circuit terminalsDegree of protectionHousingIP20Main circuit terminalsIP20Electrical connectionMain circuitTypeEF205EF370Connecting capacityRigid1 x2 x16 ... 185 mm²16 ... 120 mm²50 ... 240 mm²50 ... 150 mm²Flexible1 x2 x16 ... 185 mm²16 ... 120 mm²50 ... 240 mm²50 ... 150 mm²LugsL ≤ 24 mm32 mmBarsØ >8 mm10 mmStranded acc. to UL/CSA1 x2 xAWG 6-0000AWG 6-0000AWG 1-500 kcmilAWG 1-500 kcmilFlexible acc. to UL/CSA1 x2 xAWG 6-0000AWG 6-0000AWG 1-500 kcmilAWG 1-500 kcmilStripping length--Tightening torque18 Nm / 160 lb.in28 Nm / 247 lb.inRecommended screw driverM8M10Auxiliary circuitTypeEF205, EF370Connecting capacityRigid1 or 2 x 1 ... 4 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 or 2 x AWG 18-10Flexible acc. to UL/CSA1 or 2 x AWG 18-10Stripping length9 mmTightening torque0.8 ... 1.2 Nm / 7 ... 11 Ib.inRecommended screw driverM3.5 (Pozidriv 2)—EF205, EF370 electronic overload relays – 63 to 380 ATechnical data06
2CDC107045C0201 ABB MOTOR PROTECTION AND CONTROL 6/41—EF460, EF750, EF1250DU electronic overload relays – 150 to 1250 AOrdering detailsThe EF460, EF750 and EF1250DU are self-supplied electronic overload relays, which means no ex-tra external supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor appli-cations, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP and TEST function and a trip indication. Busbar kits are available as accessory for contactor mounting. The EF460 and EF750 have ATEX and IECEx certification (1).Setting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)AkgEF460 electronic overload relay, suitable for AF400, AF460 (1)150 ... 500 690 V: 630 A, Type gG1000 V: 1600 A, Type gG10E, 20E, 30EEF460-5001SAX721001R11011.170EF750 electronic overload relay, suitable for AF580, AF750 (1)250 ... 800 690 V: 800 A, Type gG1000 V: 1600 A, Type gG10E, 20E, 30EEF750-8001SAX821001R11013.905EF1250DU electronic overload relay, suitable for AF1350, AF1650, AF2050375 ... 1250 500 V: 1600 A, Type gG10E, 20E, 30EEF1250DU-12501SFA739001R1001(1) ATEX is valid for products produced from week 42, 2014. IECEx is valid for products produced from week 15, 2017.Ordering details accessoriesDescriptionSuitable forTy pe Order codeWeight(1 pce)kgReset push button E16, EF, TF, T16, TA200KPR-101L1SFA616162R10140.027Terminal shroudEF460LT460EF1SAX701904R00020.320Terminal shroudEF750LT750EF1SAX801904R00020.440DT500/AF460-S Mounting Kit short for mounting of EF460DU on AF460EF460DT500/AF460-S1SAX701902R10110.635DT500/AF460-L Mounting Kit long for mounting of EF460DU on AF460EF460DT500/AF460-L1SAX701902R10010.740DT800/AF750-S Mounting Kit short for mounting of EF750DU on AF750EF750DT800/AF750-S1SAX801902R10111.000DT800/AF750-L Mounting Kit long for mounting of EF750DU on AF750EF750DT800/AF750-L1SAX801902R10011.47555192 713Ø 5.2 30.9 76 5.6 153.4 76 74 149.9 152.321 58 58 28.4 38.8 32 2.17"7.56"0.28"0.51"Ø 0.2"1.22"2.99"0.22"6.04"2.99"2.91"5.9"6"0.83"2.28"2.28"1.12"1.53"1.26"186.8 22802476010019.525.5Ø741.58383 8253.32840.5103110.5184.4187.948.047.35"0.87"3.15"9.72"2.36"3.94"0.77"1"Ø0.28"1.63"3.27"3.27"3.23"2.1"1.1"1.59"4.06"4.35"7.26"7.4"1.89"EF460-500EF750-800 2CDC231013F0013 EF460-500 2CDC231014F0013EF750-8001SFC151224F0002 KPR-101LMain dimensions mm, inches 2CDC231014F0013EF1250DU-125006
2CDC107045C02016/4 2ABB MOTOR PROTECTION AND CONTROLMain circuit – Utilization characteristics according to IEC/ENTypeEF460EF750EF1250DUStandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1Rated operational voltage Ue1000 V ACRated frequency50/60 Hz – not suitable for DC applicationsTrip class10E, 20E, 30E, selectableNumber of poles3Duty time100%Operating frequency without early trippingUp to 15 operations/h, see "Technical diagram – Intermittent periodic duty"Rated impulse withstand voltage Uimp8 kVRated insulation voltage Ui1000 V ACAuxiliary circuit according to IEC/ENTypeEF460EF750EF1250DURated operational voltage Ue600 V AC / DCConventional free air thermal current Ith6 ARated frequencyDC, 50/60 HzNumber of poles1 N.C. + 1 N.O.Ie / Rated operational current AC-15acc. to IEC/EN 60947-5-1 for utilization category110-120 V50/60 Hz 3.00 A220-230-240 V50/60 Hz 3.00 A400 V50/60 Hz 1.10 A480-500 V50/60 Hz 0.75 AIe / Rated operational current DC-13acc. to IEC/EN 60947-5-1 for utilization category24 V1.50 A60 V0.55 A110-120-125 V0.55 A250 V0.27 AMinimum switching capacity12 V / 3 mAShort-circuit protective device6 A, fuse type gGRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui690 VTechnical diagram – Intermittent periodic dutyduty ratio (Op/h)switching frequency Trip class 10E (%)0 20 40 60 80 100 120 140 160 0 20406080100t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 sa2CDC232001F0214duty ratio (Op/h)switching frequency Trip class 20E (%)0 10 20 30 40 50 60 70 80 0 20406080100t = 4 sat = 8 sat = 10 sat = 12 sat = 2 sat = 6 sa2CDC232002F0214duty ratio (Op/h)switching frequency Trip class 30E (%)0 5 10 15 20 25 30 35 45 0 2040608010040 50 t = 10 sat = 20 sat = 25 sat = 5 sat = 15 sa2CDC232003F0214Trip class 10ETrip class 20ETrip class 30E—EF460, EF750, EF1250DU electronic overload relays – 150 to 1250 ATechnical data06
2CDC107045C0201 ABB MOTOR PROTECTION AND CONTROL 6/43Main circuit – Utilization characteristics according to UL/CSATypeEF460EF750EF1250DUStandardsUL60947-1, UL60947-4-1Maximum operational voltage600 V ACTrip rating125% of FLAAuxiliary circuit according to UL/CSATypeEF460EF750EF1250DUContact ratingN.C., 95-96 B600, Q300N.O., 97-98 B600, Q300Conventional thermal current5 AGeneral dataTypeEF460EF750EF1250DUPollution degree3Phase loss sensitiveYesAmbient air temperatureOperationOpen - compensated-25 ... +70 °CStorage-25 ... +70 °CAmbient air temperature compensationAcc. to IEC/EN60947-4-1Maximum operating altitude permissible2000 mResistance to shock acc. to IEC 60068-2-2725g / 11 msResistance to vibrations acc. to IEC 60068-2-63g / 3 ... 150 HzDegree of protectionHousingIP20Main circuit terminalsIP00Electrical connectionAuxiliary circuitTypeEF460EF750EF1250DUConnecting capacityRigid1 or 2 x 1 ... 4 mm²Flexible with ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible with insulated ferrule1 or 2 x 0.75 ... 2.5 mm²Flexible1 or 2 x 0.75 ... 2.5 mm²Stranded acc. to UL/CSA1 or 2 x AWG 18-10Flexible acc. to UL/CSA1 or 2 x AWG 18-10Stripping length9 mmTightening torque0.8 ... 1.2 Nm / 7 ... 11 Ib.inRecommended screw driverM3.5 (Pozidriv 2)—EF460, EF750, EF1250DU electronic overload relays – 150 to 1250 ATechnical data06
2CDC131059C02016/4 4ABB MOTOR PROTECTION AND CONTROL—Thermal and electronic overload relaysGeneral accessoriesThe wire reset is a general accessory for thermal and electronic overloads relays. In installations which are difficult to access, like a motor control centre or compact cubical, the accessory allows the user to remotely reset the overload relays.The wire reset consists of two parts, the bowden wire with actuator and the holder. The actuator should be mounted into a door of a panel. The holder will be mounted on the overload relay. The actuator and holder are connected via the bowden wire.Suitable forDescriptionLengthTy pe Order codeWeight(1 pce)mmkgHolderTF42, TF65, TF96, EF19, EF45, EF65, EF96, EF146, EF205, EF370, EF460, EF750Holder for tool less direct mountingWRH-F1SAZ701903R10010.006Bowden wire with actuatorWRH-FBowden wire with actuator, hole diameter: 7.3 mm, maximum panel thickness: 12 mm400WRB-4001SAZ701903R10110.030600WRB-6001SAZ701903R10120.0401000WRB-10001SAZ701903R10130.060IP54 gasketWRB-400WRB-600WRB-1000IP54 Panel seal gasketWRBG1SAZ701903R10300.037Overload relays with accessory wire reset (WRH, WRB)2CDC231028F0013WRB-4002CDC231027F0013WRH-FTF42 ... TF96EF19 ... EF750WRH-FWRB-400/600/100006
ABB MOTOR PROTECTION AND CONTROL 6/4506—Notes
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/CM-MSS.11P www.abb.com/productdetails/1SVR740720R1400or
ABB MOTOR PROTECTION AND CONTROL 7/1—Thermistor motor protection relays7/2 Benefits and advantages, Applications7/3 Operating controls7/4 Selection table CM-MSx range7/5 Ordering details7/6 Ordering details - PTC temperature sensors C0117/7 Technical data - CM-MSS7/10 Technical data - CM-MSE7/12 Connection diagrams7/13 Circuit diagram07
7/ 2ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysBenefits and advantages, ApplicationsThe thermistor motor protection relays of the CM-MSx range protect motors with PTC sensors against high temperature. These sensors are incorporated in the motor windings thus measuring the motor heat directly. Direct temperature measuringGenerally, motor damages caused by overload or overheat-ing situations can be prevented in different ways. Compared to the indirect temperature measuring which monitors the motor current, the temperature inside the motor can be measured by direct temperature measuring.This enables direct control and evaluation of the following operating conditions like:•Heavy duty starting•Increased switching frequency•Single phase operation•Phase unbalance•High ambient temperature•Insufficient cooling•Breaking operationTherefore the consequences from overheating like abrasionas well as electrical failures can be prevented.The direct measuring principle is carried out by a combina-tion of the thermistor motor protection relay and 3 PTC sen-sors which are installed directly in the motor by the manu-facturer. Those 3 PTC sensors are placed directly at thethermal hotspots, the motor windings.Monitoring the motorThe thermistor motor protection relay measures the resis-tance of the PTC sensors which reflects the internal motor temperature permanently. If the temperature in the motor windings rises excessively and reaches the nominal response temperature (NRT), the thermistor motor protection relay detects this situation and the output relay switches off.By doing so the motor contactor gets triggered and switches off the motor.CM-MSS functionality videoCharacteristics CM-MSE•Auto reset•Connection of several sensors (max. 6 sensors connectedin series)•Monitoring of bimetals•1 n/o contact•Excellent cost / performance ratioCharacteristics CM-MSS (1)•Different types of contacts available - 1 x 2 c/o (SPDT) contacts - 2 x 1 c/o (SPDT) contact - 1 n/o and 1 n/c contact•1 or 2 measuring circuits•Different types of reset functions - Automatic - Manual - Remote•Rated control supply voltages - 24 V AC/DC - 24-240 V AC/DC - 110-130 V AC, 220-240 V AC• Approvals / MarksA C R K E I (1) / a bFeatures (1)•Additional functions: - Dynamic interrupted wire detection - Short-circuit monitoring of the sensor circuit - Non-volatile fault storage - Single or sum evaluation•Easy configuration via DIP switches•LEDs to distinguish between different failure causes•Screw connection technology or Easy Connect Technologyavailable•Test/Reset button available(1) Depending on device the characteristics vary, for detailed overview see "Selection table CM-MSx range" on page 4. 07
ABB MOTOR PROTECTION AND CONTROL 7/3—Thermistor motor protection relaysOperating controlsLEDs, status information and fault messages CM-MSSOperational stateU: green LEDF: red LEDR: yellow LEDAbsence of control supply voltageOFFOFFOFFInternal fault (2)OFFWWInternal fault (2)XXXControl supply voltage not within the tolerance rangeXVOFFShort circuitVYOFFInterrupted wireVZOFFMeasuring circuit 2: OvertemperatureVWOFFMeasuring circuit 1: OvertemperatureVVOFFFault rectified but not confirmedV-- (1)XTest functionXOFFOFFChange of configuration not confirmed VOFFXNo faultVOFFV(1) Depending on the fault with the highest priority (2) Restart the device. If after restart the same fault is indicated, replace the device.1 Test / Reset button Reset - only possible if measured value < switch-on resistance2 Indication of operational states with LEDs U: green LED - Status indication of control supply voltage V Control supply voltage applied F: red LED - Fault message R: yellow LED - Status indication of the output relay3 Marker label / DIP switches (depending on device) e.g. i Single evaluation 2 x 1 c/o (SPDT) contact j Accumulative evaluation 1 x 2 c/o (SPDT) contacts y Short-circuit detection de-activated x Short-circuit detection activated f Non-volatile fault storage activated e Non-volatile fault storage de-activated RemoteReset Remote Reset RemoteTest/Reset Remote Test/Reset2CDC 253 001 F001512307
7/4ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysSelection table CM-MSx rangeOrder code1SVR550805R93001SVR550800R93001SVR550801R93001SVR740720R14001SVR730720R14001SVR740700R01001SVR730700R01001SVR740700R21001SVR730700R21001SVR740722R14001SVR730722R14001SVR740700R02001SVR730700R02001SVR740700R22001SVR730700R22001SVR740712R14001SVR730712R14001SVR740712R02001SVR730712R02001SVR740712R22001SVR730712R22001SVR740712R12001SVR730712R12001SVR740712R13001SVR730712R1300TypeCM-MSECM-MSECM-MSECM-MSS.11PCM-MSS.11SCM-MSS.12PCM-MSS.12SCM-MSS.13PCM-MSS.13SCM-MSS.21PCM-MSS.21SCM-MSS.22PCM-MSS.22SCM-MSS.23PCM-MSS.23SCM-MSS.31PCM-MSS.31SCM-MSS.32PCM-MSS.32SCM-MSS.33PCM-MSS.33SCM-MSS.41PCM-MSS.41SCM-MSS.51PCM-MSS.51SCharacteristicsATEX approvaln nn nn n n n n n n n n nNumber of sensor circuits1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2Single or accumulative evaluationn nNumber of LEDs3 3 2 2 2 2 3 3 2 2 2 2 3 3 3 3 3 3 3 3 3 3Contacts1 c/o (SPDT) contactn n n n2 c/o (SPDT) contactsn n n nn n n n n n1 n/on n n1 n/c and 1 n/on nn nn n2 x 1 c/o or 1 x 2 c/o contacts, configurablen nResetManualn n n n n n n n n n n n n nRemoten n n n n n n n n n n n n nAuton n n n n n n n n n nn (1)n (1)n (1)n (1)n (1)n (1)n (1)n (1)n (1)n (1)n (1)n (1)n (2)n (2)Test buttonn n n n n n n n n nFunctionsShort-circuit detectionn nn n n n n nShort-circuit detection, configurablen n n nDynamic interrupted wire detectionn nn nn n n n n n n n n nNon-volatile fault storagen nn nn nNon-volatile fault storage, configurablen n n nRated control supply voltage Us24 V ACn110-130 V ACn220-240 V ACn24-240 V AC/DCn nn nn nn n n n24 V AC/DCn nn nn n110-130 V AC, 220-240 V ACn nn nn nConnection typePush-in terminalsn n n n n n n n n n nDouble-chamber cage connection terminalsn n n n n n n n n n n(1) For automatic reset, connect terminals S1 to T2.(2) For automatic reset, connect Terminals S1 to 1T2/2T2.07
ABB MOTOR PROTECTION AND CONTROL 7/5—Thermistor motor protection relaysOrdering detailsThe thermistor motor protection relay CM-MSS monitors the winding temperature and thus protects the motor from overheating, overload and insufficient cooling in accordance to the product standard IEC 60947-8.CM-MSxCharacteristicsTy pe Order codePrice1 pceWeight(1 pce)kg (lb)See "Selection table CM-MSx range" on page 4.CM-MSE1SVR550805R93000.11 (0.24)CM-MSE1SVR550800R93000.11 (0.24)CM-MSE1SVR550801R93000.11 (0.24)CM-MSS.11P1SVR740720R14000.119 (0.263)CM-MSS.11S1SVR730720R14000.127 (0.280)CM-MSS.12P1SVR740700R01000.105 (0.231)CM-MSS.12S1SVR730700R01000.113 (0.249)CM-MSS.13P1SVR740700R21000.147 (0.324)CM-MSS.13S1SVR730700R21000.155 (0.342)CM-MSS.21P1SVR740722R14000.118 (0.260)CM-MSS.21S1SVR730722R14000.126 (0.278)CM-MSS.22P1SVR740700R02000.121 (0.267)CM-MSS.22S1SVR730700R02000.132 (0.291)CM-MSS.23P1SVR740700R22000.163 (0.359)CM-MSS.23S1SVR730700R22000.174 (0.384)CM-MSS.31P1SVR740712R14000.120 (0.265)CM-MSS.31S1SVR730712R14000.128 (0.282)CM-MSS.32P1SVR740712R02000.120 (0.265)CM-MSS.32S1SVR730712R02000.130 (0.287)CM-MSS.33P1SVR740712R22000.162 (0.357)CM-MSS.33S1SVR730712R22000.172 (0.379)CM-MSS.41P1SVR740712R12000.130 (0.287)CM-MSS.41S1SVR730712R12000.141 (0.311)CM-MSS.51P1SVR740712R13000.135 (0.298)CM-MSS.51S1SVR730712R13000.145 (0.320)S: screw connectionP: push-in connection2CDC 251 014 V00142CDC 251 013 V00142CDC 251 004 V0014CM-MSS.51SCM-MSS.41SCM-MSS.12SFurther documentation thermistor motor protection monitoring relays on www.abb.com07
7/6ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysOrdering details - PTC temperature sensors C011Technical dataCharacteristic dataSensor type C011Cold-state resistance50 -100 q at 25 °CWarm-state resistance ± 5 up to 6 K of rated response temperature TNF10 000 qThermal time constant, sensor open (1)< 5 sPermitted ambient temperature+180 °CRated response temperature w tolerance TNF w iTNFPTC resistance R from -20 °C to TNF - 20 KPTC resistance R2) at PTC temperatures of:TNF - iTNF (UPTC m 2.5 V)TNF + iTNF (UPTC m 2.5 V)TNF + 15 K (UPTC m 7.5 V)70 w5 °Cm 100 qm 570 qM 570 q-80 w5 °C90 w5 °Cm 550 qM 1330 qM 4000 q100 w5 °C110 w5 °C120 w5 °C130 w5 °C140 w5 °C150 w5 °C160 w5 °C170 w7 °Cm 570 qM 570 q-(1) Not embedded in windings. (2) For triple temperature sensor take values x 3.1SVC 110 000 F0531Temperature sensor characteristics-20 °C101102103104TNF - 20 KTNF - 5 KTNFTNF + 5 KTNF + 15 KRPTC[]TPTC [°C]2CDC 252 068 F0208The PTC temperature sensors (temperature-dependent with positive temperature coeffi-cient) are selected by the manufacturer of the motor depending on:• the motor insulation class according to IEC/EN 60034-11,• the special characteristics of the motor, such as the conductor cross-section of the wind-ings, the permissible overload factor etc.• special conditions prescribed by the user, such as the permissible ambient temperature,risks resulting from locked rotor, extent of permitted overload etc.One temperature sensor must be embedded in each phase winding. For instance, in case of three-phase squirrel cage motors, three sensors are embedded in the stator windings. For pole-changing motors with one winding (Dahlander connection), 3 sensors are also suffi-cient. Pole-changing motors with two windings, however, require The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conduc-tor length: 500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from overvoltage. Due to their characteristics, the thermistor motor protection re-lays can also be used with PTC temperature sensors of other manufacturers which comply with DIN 44 081 and DIN 44 082 6 sensors.If an additional warning is required before the motor is switched off, separate sensors for a correspon dingly lower temperature must be embedded in the winding. They have to be con-nected to a second control unit.CM-MSS accessoriesRated response temperature TNFColor codingTy pe Order codePrice1 pceWeight(1 pce)kg (lb)70 °Cwhite-brownC011-70 (1)GHC0110003R00010.02 (0.044)80 °Cwhite-whiteC011-80 (1)GHC0110003R00020.02 (0.044)90 °Cgreen-greenC011-90 (1)GHC0110003R00030.02 (0.044)100 °Cred-redC011-100 (1)GHC0110003R00040.02 (0.044)110 °Cbrown-brownC011-110 (1)GHC0110003R00050.02 (0.044)120 °Cgray-grayC011-120 (1)GHC0110003R00060.02 (0.044)130 °Cblue-blueC011-130 (1)GHC0110003R00070.02 (0.044)140 °Cwhite-blueC011-140 (1)GHC0110003R00110.02 (0.044)150 °Cblack-blackC011-150 (1)GHC0110003R00080.02 (0.044)160 °Cblue-redC011-160 (1)GHC0110003R00090.02 (0.044)170 °Cwhite-greenC011-170 (1)GHC0110003R00100.02 (0.044)150 °Cblack-blackC011-3-150 (2)GHC0110033R00080.05 (0.11)(1) Temperature sensor C011, standard version acc. to DIN 44081(2) Triple temperature sensor C011-307
ABB MOTOR PROTECTION AND CONTROL 7/7—Thermistor motor protection relaysTechnical data - CM-MSSData at Ta = 25 °C and rated values, unless otherwise indicatedSupply circuit - Input circuitCM-MSS.x1CM-MSS.x2CM-MSS.x3Rated control supply voltage Us A1-A224-240 V AC/DC24 V AC/DC220-240 V ACA2-A3--110-130 V ACRated control supply voltage Us tolerance-15...+10 %Rated frequency15-400 Hz50-60 HzElectrical insulation between supply circuit and measuring circuityesnoyesPower failure buffering time20 msSupply circuit - Measuring circuit / Sensor circuitNumber of circuits1 (CM-MSS.51: 2)Sensor typePTC type A (DIN/EN 44081, DIN/EN 44082)Max. total resistance of sensors connected in series, cold state< 750 WOvertemperature monitoringswitch-off resistance (relay de-energizes)2.83 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 kW w 5%)switch-on resistance (relay energizes)1.1 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 kW w 5%)Maximum voltage in sensor circuit1.33 kW 2.5 V4 kW 3.7 Vy kW5.5 VMaximum current in sensor circuit3.7 mAMaximum sensor cable length2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²Accuracy within the rated control supply voltage tolerance0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %)Accuracy within the temperature range0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K)Repeat accuracy (constant parameters)on requestReaction time of the safety function< 100 msHardware fault tolerance (HFT)0Control circuitControl functionsee "Selection table CM-MSx range" on page 4Maximum no-load voltage5.5 VMax. current0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA)Maximum cable length2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²Indication of operational statesControl supply voltageULED greenRelay statusRLED yellowFault messageFLED redOutput circuitKind of outputsee "Selection table CM-MSx range" on page 4Operating principleclosed-circuit principleContact materialAgNi alloy, Cd freeRated operational voltage Ue (IEC/EN 60947-1)250 V ACMinimum switching voltage / Minimum switching current24 V / 10 mAMaximum switching voltage / Maximum switching currentsee data sheetRated operating current Ie (IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 AAC-15 (inductive) at 230 V 3 ADC-12 (resistive) at 24 V 4 ADC-13 (inductive) at 24 V 2 AAC Rating (UL 508)utilization category (Control Circuit Rating Code) B 300maximum rated operational voltage300 V ACmaximum continuous thermal current at B 300 5 Amaximum making/breaking apparent power at B 3003600/360 VAgeneral purpose rating250 V AC - 4 AMechanical lifetime30 x 106 switching cyclesElectrical lifetimeat AC12, 230 V AC, 4 A 0.1 x 106 switching cyclesMaximum fuse rating to achieve short-circuit protectionn/c contact10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A)n/o contact10 A fast-acting07
7/ 8ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysTechnical data - CM-MSSGeneral dataMTBFon requestDuty time100 %Dimensions (W x H x D)product dimensions22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)packaging dimensions97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)Weightsee "Ordering details" on page 5MountingDIN rail (IEC/EN 60715), snap-on mounting without any toolMounting positionanyMinimum distance to other unitsvertical10 mm (0.394 in) if switching current > 2 Ahorizontal10 mm (0.394 in) if switching current > 2 AMaterial of housingUL 94 V-0Degree of protectionhousingIP50terminalsIP20Electrical connectionScrew connection technologyEasy Connect Technology (push-in)Connection capacityfine-strand with(out) wire end ferrule1 x 0.5-2.5 mm² (1 x 18-14 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG)2 x 0.5-1.5 mm² (2 x 18-16 AWG)rigid1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)2 x 0.5-1.5 mm² (2 x 20-16 AWG)Stripping length8 mm (0.32 in)Tightening torque0.6-0.8 Nm (7.08 lb.in)-Wire end ferruleaccording to DIN 46228-1-A, DIN 46228-4-E-Environmental dataAmbient temperature rangesoperation-25...+60 °C (-13...+140 °F)storage-40...+85 °C (-40...+185 °F)Damp heat, cyclic (IEC/EN 60068-2-30)6 x 24 h cycle, 55 °C, 95 % RHClimatic class (IEC/EN 60721-3-3)3K5 (no condensation, no ice formation)Vibration, sinusoidal (IEC/EN 60255-21-1)Class 2Shock (IEC/EN 60255-21-2)Class 2Isolation dataRated insulation voltage Ui (IEC/EN 60947-1, IEC/EN 60664-1)Supply circuit / Measuring circuit (1)300 V AC (CM-MSS.x2: n/a)Supply circuit / Output circuits300 V ACMeasuring circuit (1) / Output circuits300 V ACOutput circuit 1 / Output circuit 2 300 V ACRated impulse withstand voltage Uimp (IEC/EN 60947-1, IEC/EN 60664-1)Supply circuit / Measuring circuit (1)4 kV / 6 kV (CM-MSS.x2: n/a)Supply circuit / Output circuits4 kV / 6 kVMeasuring circuit (1) / Output circuits4 kV / 6 kVOutput circuit 1 / Output circuit 2 4 kVBasic insulation (IEC/EN 60664-1)Supply circuit / Measuring circuit (1)600 V AC (CM-MSS.x2: n/a)Supply circuit / Output circuits600 V ACMeasuring circuit (1) / Output circuits600 V ACOutput circuit 1 / Output circuit 2 300 V ACTest voltage, routine test (IEC/EN 60255-27)Supply circuit / Measuring circuit (1)2.5 kV, 50 Hz, 1 min. (CM-MSS.x2: n/a)Supply circuit / Output circuits2.5 kV, 50 Hz, 1 min.Measuring circuit (1) / Output circuits2.5 kV, 50 Hz, 1 min.Test voltage, type test (IEC/EN 60255-27)Supply circuit / Measuring circuit (1)6 kV / 1.2 - 50 μs (CM-MSS.x2: n/a)Supply circuit / Output circuits6 kV / 1.2 - 50 μsMeasuring circuit (1) / Output circuits6 kV / 1.2 - 50 μsOutput circuit 1 / Output circuit 2 6 kV / 1.2 - 50 μsProtective separation (IEC/EN 61140, EN 50178)Supply circuit / Measuring circuit (1)yes, up to 300 VSupply circuit / Output circuitsyes (CM-MSS.x2: n/a)Measuring circuit (1) / Output circuitsyesOutput circuit 1 / Output circuit 2noPollution degree (IEC/EN 60664-1)3Overvoltage category (IEC/EN 60664-1)III(1) Potential of measuring circuit = Potential of control circuit07
ABB MOTOR PROTECTION AND CONTROL 7/9—Thermistor motor protection relaysTechnical data - CM-MSSStandardsProduct standardEN 60947-5-1, EN 60947-8Low Voltage Directive2014/35/ECEMC directive2014/30/EC ATEX directive2014/34/EC (only ATEX variants "Selection table CM-MSx range" on page 4)RoHS directive2011/65/ECElectromagnetic compatibilityInterference immunity toIEC/EN 61000-6-1, IEC/EN 61000-6-2electrostatic dischargeIEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air dischargeradiated, radio-frequency, electromagnetic fieldIEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz)electrical fast transient / burstIEC/EN 61000-4-4 Level 3, 2 kV / 5 kHzsurgeIEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-Nconducted disturbances, induced by radio-frequency fieldsIEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz)voltage dips, short interruptions and voltage variationsIEC/EN 61000-4-11 Class 3harmonics and interharmonicsIEC/EN 61000-4-13 Class 3Additional interference immunity according to product standard EN 60255-1 (reference on EN 60255-26_2011)radiated, radio-frequency, electromagnetic fieldIEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz)conducted disturbances, induced by radio-frequency fieldsIEC/EN 61000-4-6 10 V at stated frequenciesdamped oscillatory wavesIEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltagePower supply, asymmetric coupling: 2.5 kV peak voltageInterference emissionsIEC/EN 61000-6-3, IEC/EN 61000-6-4high-frequency radiatedIEC/CISPR 22, EN 55022Class Bhigh-frequency conductedIEC/CISPR 22, EN 55022Class Bhigh-frequency radiatedGermanischer Lloydincreased requirements in the emergency call frequency band07
7/ 1 0ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysTechnical data - CM-MSEData at Ta = 25 °C and rated values, unless otherwise indicatedSupply circuit - Input circuitCM-MSERated control supply voltage Us power consumption1SVR550805R930024 V AC approx. 1.5 A1SVR550800R9300110-130 V AC approx. 1.5 A1SVR550801R9300220-240 V AC approx. 1.5 ARated control supply voltage Us tolerance-15...+10 %Rated frequency50-60 HzMeasuring circuitMonitoring functionT1-T2temperature monitoring by means of PTC sensorsNumber of sensor circuits1Sensor circuitTemperature threshold (relay de-energizes)2.7-3.7 kWTemperature hysteresis (relay energizes)1.7-2.3 kWShort-circuit threshold (relay de-energizes)<18 WShort-circuit hysteresis (relay energizes)>45 WMaximum total resistance of sensors connected in series (cold state)m1.5 kWMaximum sensor cable length for short-circuit detection2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²Response time<100 msOutput circuitKind of output13-141 n/o contactOperational principleclosed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold)Contact materialAgCdORated voltageVDE 0110, IEC 664-1, IEC 60947-1 250 VMaximum switching voltage250 VRated operating current Ie (IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 AAC-15 (inductive) at 230 V 3 ADC-12 (resistive) at 24 V 4 ADC-13 (inductive) at 24 V 2 AAC Rating (UL 508)utilization category (Control Circuit Rating Code) B 300maximum rated operational voltage300 V ACmaximum continuous thermal current at B 300 5 Amaximum making/breaking apparent power at B 300 3600/360 VAgeneral purpose rating250 V AC - 4 AMechanical lifetime30 x 106 switching cyclesElectrical lifetimeat AC12, 230 V AC, 4 A 0.1 x 106 switching cyclesMaximum fuse rating to achieve short-circuit protectionn/c contact10 A fast-actingn/o contact10 A fast-actingGeneral dataDimensions (W x H x D)22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)Duty time100 %Weightapprox. 0.11 kg (0.24 lb)Mounting positionanyDegree of protectionhousing / terminalsIP50 / IP20Ambient temperature rangeoperation-20...+60 °Cstorage-40...+85 °CMountingDIN rail (IEC/EN 60715)Electrical connectionWire sizefine strand with wire end ferrule2 x 1.5 mm² (2 x 16 AWG)fine strand without wire end ferrule2 x 0.75-1.5 mm² (2 x 18-16 AWG)rigid2 x 1-1.5 mm² (2 x 18-16 AWG)Stripping length2 x 0.75-1.5 mm² (2 x 18-16 AWG)Tightening torque0.6-0.8 Nm (5.31-7.08 lb.in)StandardsProduct standardIEC 255-6, EN 60255-6Low Voltage Directive2006/95/ECEMC Directive2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EECElectromagnetic compatibilityelectrostatic dischargeIEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)radiated, radio-frequency, electromagnetic fieldIEC/EN 61000-4-3 Level 3 (10 V/m)electrical fast transient /burstIEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)surgeIEC/EN 61000-4-5 Level 3/4 (1/2 kV)conducted disturbances, induced by radio-frequency fieldsIEC/EN 61000-4-6 Level 3 (10 V)Operational reliability (IEC 68-2-6)6 gResistance to vibration (IEC 68-2-6)10 gEnvironmental testing (IEC 68-2-30)24 h cycle time, 55 °C, 93 % rel., 96 hElectromagnetic compatibilityRated voltage between supply, measuring and output circuit250 VRated impulse withstand voltage between all isolated circuits4 kV / 1.2 - 50 μsTest voltage between all isolated circuits2.5 kV, 50 Hz, 1 min.Pollution degree3Overvoltage categoryIII07
ABB MOTOR PROTECTION AND CONTROL 7/11—Notes0707
7/ 1 2ABB MOTOR PROTECTION AND CONTROL—Thermistor motor protection relaysConnection diagramsCM-MSS.22, CM-MSS.32, CM-MSS.41CM-MSS.51CM-MSECM-MSS.23, CM-MSS.33A1 – A2Control supply voltage 24 V AC/DC11 – 12/141st c/o (SPDT) contact21 – 22/242nd c/o (SPDT) contactS1 – T2Automatic reset(jumpered)T1 – T2Measuring circuitA1 – A2Control supply voltage 220-240 V AC11 – 12/141st c/o (SPDT) contact21 – 22/242nd c/o (SPDT) contactS1 – 1T2/2T2Automatic reset (jumpered)1T1 – 1T2/2T2 Measuring circuit 12T1 – 1T2/2T2 Measuring circuit 2A1 – A2Control supply voltage 24 V ACT1-T2Sensor circuit13-14Output contact - Closed circuit principleA1 – A2Control supply voltage 220-240 V ACA2 – A3Control supply voltage 110-130 V AC11 – 12/141st c/o (SPDT) contact21 – 22/242nd c/o (SPDT) contactS1 – T2Automatic reset (jumpered)T1 – T2Measuring circuitA11121T2T12422S11412A2θT2S1T1 A1A2 12112114 22 24A1A31121T2T114122422S1A2S1θT2T1 A1 A3A2222124121114A111211T1 1T2/2T2 2T12422S11412A2θθS1S1A11112 142122 24A21T1A12T11T2/2T2A21T2/2T2A113T2T114A2θT2T1 A11413A22CDC 252 019 F00142CDC 252 021 F00142CDC 252 017 F00141SVC 110 000 F0140CM-MSS.11, CM-MSS.21CM-MSS.13CM-MSS.31CM-MSS.12A1 – A2Control supply voltage13 – 14n/o contact21 – 22n/c contactT1 – T2Measuring circuitA1 – A2Control supply voltage 220-240 V ACA2 – A3Control supply voltage 110-130 V AC11 – 12/14c/o contactT1 – T2Measuring circuitA1 – A2Control supply voltage13 – 14n/o contact21 – 22n/c contactS1 – T2Automatic reset (jumpered)T1 – T2Measuring circuitA1 – A2Control supply voltage11 – 12/14c/o contactT1 – T2Measuring circuitA11321T2T11422A2θT2T1 A11413 2122A22CDC 252 018 F0014A111T2T11412A2T2T1 A1A2121114θ2CDC 252 022 F0014A1A311T2T11412A2θT2T1 A1 A3A21211142CDC 252 020 F0014A11321T2S1T11422A2θT2T1 A11413 2122A2S12CDC 252 047 F001407
ABB MOTOR PROTECTION AND CONTROL 7/13—Thermistor motor protection relaysCircuit diagramCM-MSE1SVC 110 000 F0141CM-MSS.32, CM-MSS.41CM-MSS.33CM-MSS.51M 3~V+T2T1A1μCV-tA2S1241121221412ResetM 3~V+T2T1A1 or A3μCV-tA2S1241121221412Reset2CDC 252 015 F00142CDC 252 029 F0014M 3~M 3~V+1T2/2T22T11T1A1μCV-ttA2S1241121221412Reset2CDC 252 016 F0014CM-MSS.31CM-MSS.23CM-MSS.22M 3~V+T2T1A1 or A3V-tA2S1241121221412ResetM 3~V+T2T1A1V-tA2S1241121221412Reset2CDC 252 026 F00142CDC 252 027 F0014M 3~V+T2T1A1μCV-tA2S1211422Reset132CDC 252 028 F0014CM-MSS.11, CM-MSS.21CM-MSS.12CM-MSS.13M 3~V+T2T1A1μCV-tA221142213M 3~V+T2T1A1V-tA21411122CDC 252 023 F00142CDC 252 024 F0014M 3~V+T2T1A1 or A3V-tA21411122CDC 252 025 F001407
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/S801S-SCL32-SRwww.abb.com/productdetails/2CCS801901R0539or
08ABB MOTOR PROTECTION AND CONTROL 8/1—Self resetting current limiting moduleS800-SCL-SR8/2 Ordering details8/3 Technical data08
8/2ABB MOTOR PROTECTION AND CONTROL2CCC413012B0201—S800-SCL-SRSelf-resetting current limiting moduleS800S-SCL-SR/S803S-SCL79.505326.5035459576.50466S803W-SCL-SR79.505326.5035459514 276.504662CCC413380F00012CCC413381F0001S800S-SCL-SRS803W-SCL-SRS800-SCL-SR is ABB’s innovative self-resetting current limiting module which considerably increases the short-circuit breaking capacity of downstream manual motor starters and high performance MCBs. S800-SCL-SR is a self resetting current limiting module based on the S800 technology. It limits the short-circuit current until the downstream means of protection trips. Its current continuity makes it as the ideal solution for group protection: All parallel branches remain operative. This leads to an Expanded application range of the low voltage switchgear whose short-circuit capabilities are usually limited. S800-SCL-SR can be combined with S800S high performance MCB or with manual motor starters. S800-SCL-SR can also back up a single circuit breaker or a group of circuit breakers or motor starters (group protection). Terminals and outside dimensions are identical to the S800 range.Self-resettingType designationProduct numberEAN numberWeightPack.short-circuit limiter IEC versionA7612271kgunit1-pole32S801S-SCL32-SR2CCS801901R05394120120.25163S801S-SCL63-SR2CCS801901R05994120360.251100S801S-SCL100-SR2CCS801901R06394119920.2512-pole32S802S-SCL32-SR2CCS802901R05394120740.5163S802S-SCL63-SR2CCS802901R05994120980.51100S802S-SCL100-SR2CCS802901R06394120500.513-pole32S803S-SCL32-SR2CCS803901R05394119300.75163S803S-SCL63-SR2CCS803901R05994119470.751100S803S-SCL100-SR2CCS803901R06394119540.751Self-resetting short-circuit limiter IEC/UL versionType designationProduct numberEAN numberWeightPack.A7612271kgunit3-pole32S803W-SCL32-SR2CCS803917R05394123190.75163S803W-SCL63-SR2CCS803917R05994123260.751100S803W-SCL100-SR2CCS803917R06394123020.751Main dimensions mm, inches08
ABB MOTOR PROTECTION AND CONTROL 8/32CCC413012B0201—S800S-SCL-SR/S803W-SCL-SRTechnical dataS800S-SCL-SRS803W-SCL-SRRated operational current Ie [A]32, 63, 10032, 63, 100Pole1, 2, 33Rated operational voltage Ue (AC) according to IEC 60947-2 50/60 Hz[V]400/690690(AC) according to UL 508 50/60 Hz[V]600Rated insulation voltage Ui [V]690690Rated impulse withstand voltage Uimp [kV]88Rated ultimate short-circuit breaking capacityIcu = Ics according to IEC 60947-2 *(AC) 50/60 Hz 240/415 V [kA]100100(AC) 50/60 Hz 254/440 V [kA]100100(AC) 50/60 Hz 277/480 V[kA]6565(AC) 50/60 Hz 289/500 V[kA]6565(AC) 50/60 Hz 346/600 V [kA]6565(AC) 50/60 Hz 400/690 V[kA]5050Short-circuit rating according to UL 508, CSA 22.2 *(AC) 50/60 Hz 480 V[kA]6565(AC) 50/60 Hz 600 V[kA]6565* Valid only for approved combinationsRated frequency[Hz]50/6050/60Mounting positionanyanyConnections Cu [mm²]1 ... 50 rigid (solid/stranded)1 ... 50 rigid (solid/stranded)[mm²]1 ... 70 flexible1 ... 70 flexible14–1 AWGTightening torque[Nm]min. 3 / max. 4min. 3 / max. 4[in. lbs.]min. 26.5 / max. 25Feeding optionaloptionalMouting on DIN top hat rail EN 60715EN 60715Ambient air temperature [°C]–40 ... +70–40 ... +70Storage temperature [°C]–40 ... +85–40 ... +85Degree of protection IP20IP20Classification acc. to NF F 16-101, NF F 16-102I3, F2I3, F2Damp HeatIEC 60068-2-30, 55 °C / 95 % r.h.IEC 60068-2-30, 55 °C / 95 % r.h.VibrationIEC 60068-2-6, 5–10 Hz / 3 mm and 10–500 Hz /2 g at 0.5 x IeIEC 60068-2-6, 5–10 Hz / 3 mm and 10–500 Hz / 2 g at 0.5 x IeRandom VibrationIEC 60068-2-64, 5–500 Hz / 2 g at 0.5 x IeIEC 60068-2-64, 5–500 Hz / 2 g at 0.5 x IeResistance to climatic conditionsIEC 60068-2-1 /-2-2 /-2-30IEC 60068-2-1 /-2-2 /-2-30Standard IEC 60947-2IEC 60947-4-1IEC 60947-2 IEC 60947-4-1 UL 508, CSA 22.2 No. 14Internal resistance at 25°C ambient temperature and nominal power lossesRated current InInternal resistance RiPower losses PvnAmΩ/poleW/p ol e322.83.6631.35.71000.77.8Influence of ambient temperature – single mounted devicesRated current In 10°C15°C20°C25°C30°C35°C40°C45°C50°C55°C60°C65°C70°CA3238.237.235.835.234.233.33230.729.828.827.826.525.16375.373.270.669.367.465.56360.558.656.754.852.349.8100119.5116.211211010710410096939087848008
8/4ABB MOTOR PROTECTION AND CONTROL2CCC413012B0201—S800-SCL-SRTechnical dataShort circuit breaking capacityS800S-SCL-SRS803W-SCL-SRRated ultimate short-circuit breaking capacityIcu = Ics according to IEC 60947-2 (AC) 50/60 Hz 240/415 V [kA]100100(AC) 50/60 Hz 254/440 V [kA]100100(AC) 50/60 Hz 277/480 V [kA]6565(AC) 50/60 Hz 289/500 V [kA]6565(AC) 50/60 Hz 346/600 V [kA]6565(AC) 50/60 Hz 400/690 V [kA]5050Short-circuit rating according to UL 508, CSA 22.2 (AC) 50/60 Hz 480 V [kA]65(AC) 50/60 Hz 600 V [kA]65CoordinationTy pe230 V AC400 V AC440 V ACFuseCurrent LimiterFuseCurrent LimiterFuseCurrent LimiterIcs Icu gG, aMS803x-SCL-SRIcs Icu gG, aMS803x-SCL-SRIcs Icu gG, aMS803x-SCL-SRkA kA kA A kA A kA kA kA A kA A kA kA kA A kA AMS132-0.16MS132-0.25MS132-0.4MS132-0.63MS132-1.0No back-up requiredNo back-up requiredNo back-up requiredMS132-1.6MS132-2.5MS132-4.0202010063100 32,63,100MS132-6.32020100 100 100 32,63,100MS132-102020100 100 100 32,63,100MS132-122020100125100 32,63,100MS132-162020100125100 32,63,100MS132-202020100125100 32,63,100MS132-255050100125100 63,1005050100125100 63,1002020100125100 63,100MS132-322550100125100 63,1002550100125100 63,1002020100125100 63,100Ty pe500 V AC600 V ACFuseCurrent LimiterFuseCurrent LimiterIcs Icu gG, aMS803x-SCL-SRIcs Icu gG, aMS803x-SCL-SRkA kA kA A kA A kA kA kA A kA A MS132-0.16MS132-0.25MS132-0.4MS132-0.63MS132-1.0No back-up requiredNo back-up requiredMS132-1.6MS132-2.520201003565*32, 63,10033803550**32, 63,100MS132-4.020201006365*32, 63,10033806350**32, 63,100MS132-6.32020100 10065*32, 63,100338010050**32, 63,100MS132-102020100 10065*32, 63,100338010050**32, 63,100MS132-12202010012565*32, 63,100338012550**32, 63,100MS132-16202010012565*32, 63,100338012550**32, 63,100MS132-20202010012565*32, 63,100338012550**32, 63,100MS132-25101010012565*63,100338012550**63,100MS132-32101010012565*63,100338012550**63,100* 100 k A when two current limiters are used in series.** 80 k A when two current limiters are used in series.08
ABB MOTOR PROTECTION AND CONTROL 8/52CCC413012B0201—S800-SCL-SR and S803S-SCLTechnical dataInstallation requirementsThe total sum of the rated currents of all downstream motor starters or circuit breakers shall not exceed the rated current of the S800-SCL-SR. Furthermore the sum of all load currents including inrush currents shall not exceed the maximum permissible load of the S800-SCL-SR.Maximum loadMultiple of the rated operational current IeTime in s1000010001001011101000.10.01time [s]n x Ie08
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/DRAS09-20Swww.abb.com/productdetails/1SBK104235R2000or
DRAS enclosed starter9/2 Ordering details9/3 Control supply wiring versions9/3 Wiring diagram9/3 Main dimensions9/4 Voltage code table DRAF enclosed starter9/6 Experience reliable and easy to install motor starting9/8 Ordering details9/10 Control supply wiring versions9/10 Wiring diagram9/10 Main dimensions—DRAS and DRAF enclosed starters09 ABB MOTOR PROTECTION AND CONTROL 9/1
1SBC133001S02019/2ABB MOTOR PROTECTION AND CONTROL—DRAS09 ... DRAS16 enclosed direct-on-line starters4 to 7.5 kW, protected by thermal overload relaysAC or DC operatedEnclosed direct-on-line (DOL) starters are used for controlling 3-phase asynchronous motors up to 690 V AC.Each starter is delivered assembled and wired. It contains:•IP65 compact plastic enclosure with double insulation, equipped with: - 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button - 2 quarter-turn, quick fastening screws and a base with 6 cable inlets and outlets via knockouts.•1 AS or ASL 3-pole contactor with holding contact•1 PE and 1 neutral terminal.3 versions of control supply wiring are available: phase-to-phase, separate supply or phase-to-neutral.T16 thermal overload relay has to be ordered separately and choses according to motor's nominal current (see table below).DRAS, DRASL enclosed DOL startersIEC - AC-3Rated control circuit voltageUcOther control voltages see AS voltage code tableControl supply wiringTy pe Order codeWeightPkg(1 pce)Rated operationalpowermax. currentθ ≤ 40 °CUe=400 V220 V230 V240 V400 V500 VkWkWkWAV 50/60 HzV DCkgAC operated with AS 3-pole contactors2.244924-Separate supplyDRAS09-20S1SBK104235R20000.650230-Phase-to-neutralDRAS09-26N1SBK104135R26000.650240-Phase-to-neutralDRAS09-27N1SBK104135R27000.650400-Phase-to-phaseDRAS09-28P1SBK104035R28000.650415-Phase-to-phaseDRAS09-29P1SBK104035R29000.65035.55.51224-Separate supplyDRAS12-20S1SBK114235R20000.650230-Phase-to-neutralDRAS12-26N1SBK114135R26000.650240-Phase-to-neutralDRAS12-27N1SBK114135R27000.650400-Phase-to-phaseDRAS12-28P1SBK114035R28000.650415-Phase-to-phaseDRAS12-29P1SBK114035R29000.65047.57.515.524-Separate supplyDRAS16-20S1SBK124235R20000.650230-Phase-to-neutralDRAS16-26N1SBK124135R26000.650240-Phase-to-neutralDRAS16-27N1SBK124135R27000.650400-Phase-to-phaseDRAS16-28P1SBK124035R28000.650415-Phase-to-phaseDRAS16-29P1SBK124035R29000.650DC operated with ASL 3-pole contactors2.2449-24Separate supplyDRASL09-81S1SBK104335R81000.700-48DRASL09-83S1SBK104335R83000.70035.55.512-24Separate supplyDRASL12-81S1SBK114335R81000.700-48DRASL12-83S1SBK114335R83000.70047.57.515.5-24Separate supplyDRASL16-81S1SBK124335R81000.700-48DRASL16-83S1SBK124335R83000.700T16 thermal overload relays to be ordered separatelySetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)Akg0.10...0.130.5 A, Fuse type T10T16-0.131SAZ711201R10050.1000.13...0.171.0 A, Fuse type TT16-0.171SAZ711201R10080.1000.17...0.23T16-0.231SAZ711201R10090.1000.23...0.31T16-0.311SAZ711201R10130.1000.31...0.412.0 A, Fuse type gGT16-0.411SAZ711201R10140.1000.41...0.55T16-0.551SAZ711201R10170.1000.55...0.744.0 A, Fuse type gGT16-0.741SAZ711201R10210.1000.74...1.006.0 A, Fuse type gGT16-1.01SAZ711201R10230.1001.00...1.30T16-1.31SAZ711201R10250.1001.30...1.7010.0 A, Fuse type gGT16-1.71SAZ711201R10280.1001.70...2.30T16-2.31SAZ711201R10310.1002.30...3.10T16-3.11SAZ711201R10330.1003.10...4.2020.0 A, Fuse type gGT16-4.21SAZ711201R10350.1004.20...5.70T16-5.71SAZ711201R10380.1005.70...7.6035.0 A, Fuse type gGT16-7.61SAZ711201R10400.1007.60...10.0T16-101SAZ711201R10430.10410.0...13.040.0 A, Fuse type gGT16-131SAZ711201R10450.10413.0...16.0T16-161SAZ711201R10470.104Empty enclosure with push-button---FR16AS-12VARS1SBN101035R10000.394To be completed with AS or ASL contactor, T16 thermal overload relay and MCB-10B (1SFA611610R2001) contact block.Empty enclosurewith push-button1SBC133001V0014DRAS+ T16 to be ordered separately1SBC133003V0014T162CDC231009V001309
1SBC133002S0201ABB MOTOR PROTECTION AND CONTROL 9/3—DRAS09 ... DRAS16 andDRASL09 ... DRASL16 enclosed direct-on-line startersWiring diagramAC local controlDR AS09 ... DR AS16 + T16DC local controlDRASL09 ... DRASL16..S + T16Power circuit1-phase2/T14/T26/T35/L33/L21/L12/T1984/T26/T314KM1A1A2AMRESETTESTFR1STOP9695972/T14/T26/T35/L33/L21/L12/T14/T26/T31314FR113KM1A1A21314KM1AMRESETSTOP-3-4IFR19596IDRAS..PDRAS..NDRAS..SUsKM1: 5/L3KM1: 3/L2UsNDRAS..NDRAS..SDRAS..PAMRESETSTOPFR195961314-3-4KM1KM1A1+A2--+DRAS09, DRAS12, DRAS16DRASL09, DRASL12, DRASL16M5M592 3.62"131.5 5.18"126.5 4.98"7.5 0.30"5.5 0.22"171.5 6.75"160 6.30"7.5 0.30"5.5 0.22"Cable inletsCable outletEnclosure topEnclosure backEnclosure bottom2 x ø 20.5/25.5 mm 2 x ø 20.5 mm 2 x ø 20.5/25.5 mm2 x ø 0.81/1.00"2 x ø 0.81"2 x ø 0.81/1.00"ø 20.5mm - ø 0.81" for ISO M20ø 25.5mm - ø 1.00" for ISO M25Control supply wiring versions1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRAS1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRASSeparate supplyDRAS..S, DRASL..S1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRASPhase-to-neutralDRAS..NA1A2Uc= UDA.Cod1Phase-to-phaseDRAS..PMain dimensions mm, inches09
9/4ABB MOTOR PROTECTION AND CONTROL1SBC133003S0201—Voltage code tableDRAS09 ... DRAS16 andDRASL09 ... DRASL16 enclosed DOL startersTy peContactor typeAC operatedDC operatedDR AS16 -26NASASLAS contactorsAC coil codeASL contactorsDC coil codeControl supply wiring50 Hz60 Hz20S24 V24 V81S24 VSSeparate supply21S42 V 42 V83S48 V22S48 V48 V16N-120 VNPhase-to-neutral23N110 V110 V24N115 V115 V25N220 V220 V26N230 V230 V27N240 V240 V13P380 V380 VPPhase-to-phase17P-277 V28P400 V400 V29P415 V415 V09
09ABB MOTOR PROTECTION AND CONTROL 9/5—Notes
1SBC133007S02019/6ABB MOTOR PROTECTION AND CONTROL—DRAF enclosed direct-on-line startersExperience reliable and easy to install motor startingFor machine or wall mountingMain applicationsControl of stand alone motors like for heat pumps, air conditioning units, small machine tools, compressors, pumping, irrigation...Improve installation efficiency•Easy to connect and to operate•Pre-wired control circuit and easy to follow wiring instructions•Coil energy consumption down by 80%.Reliable in harsh condition•High number of electrical and mechanical operations•Robust IP66 and type 4X enclosure•Double electrical insulation.Continuous operation•AF contactors manage voltage fluctuation, chattering free•Protected motor with thermal overload relay•Safety through coordinated product.09
Motor starting solutions up to 7.5 kW and 10 hpAF 3-pole contactor with holding contact4 cable entries1 PE and 1 neutral terminalTF42 thermal overload relayStart contact block"I" ON button"0" OFF/RESET button1SBC133008S0201ABB MOTOR PROTECTION AND CONTROL 9/709
1SBC133006S02019/8ABB MOTOR PROTECTION AND CONTROL—DRAF09 ... DRAF16 enclosed direct-on-line startersUp to 7.5 kW and 10 hp, protected by thermal overload relaysAC operatedEnclosed direct-on-line (DOL) starters are used for controlling 3-phase asynchronous motors up to 690 V AC. Each starter is delivered assembled and wired. It contains:•IP66 and type 4X plastic enclosure with double insulation, equiped with: - 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button - 4 cable inlets and outlets via knockouts.•1 AF 3-pole contactor with holding contact•1 CB5-10 start contact block•1 PE and 1 neutral terminal.Control supply wiring: IEC starters type: phase-to-phase, separate supply or phase-to-neutral. UL starters type: separate supply. TF42 thermal overload relay to be ordered separately and choses according to motor's nominal current (see table in the next page).DRAF enclosed DOL startersIEC - AC-3Control supply wiringRated control circuit voltageUc min ... Uc max(1)Ty pe Order codeWeightPkg(1 pce)Rated operationalpowermax. currentθ ≤ 40 °CUe=400 V220 V230 V240 V380 V 400 V500 V690 VkWkWkWkWAV 50/60 HzkgIEC starters type2.245.5 5.59Separate supply24...60DRAF09-11S1SBK134237R11000.820Phase-to-neutral100...250DRAF09-13N1SBK134137R13000.820Phase-to-phase250...500DRAF09-14P1SBK134037R14000.82035.57.5 7.512Separate supply24...60DRAF12-11S1SBK154237R11000.820Phase-to-neutral100...250DRAF12-13N 1SBK154137R13000.820Phase-to-phase250...500DRAF12-14P1SBK154037R14000.82047.59918Separate supply24...60DRAF16-11S1SBK174237R11000.820Phase-to-neutral100...250DRAF16-13N1SBK174137R13000.820Phase-to-phase250...500DRAF16-14P1SBK174037R14000.820(1) Select DR AF..S with separate supply for 24...60 V DC control circuit voltage (change A2 - Us wire to blue color acc. to IEC 60947-4-1).UL starter type with separate control supply wiringUL / CSARated control circuit voltageUc min ... Uc maxTy pe Order codeWeightPkg(1 pce)Horse power ratingsSingle phase motorThree phase motor120 V240 V 200 V 208 V220 V 240 V440 V 480 V550 V 600 VhphphphphphpV 50/60 HzkgUL starters type0.751.52257.524...60DRAF09-11U1SBK134238R11000.820100...250DRAF09-13U1SBK134238R13000.820250...500DRAF09-14U1SBK134238R14000.82012337.51024...60DRAF12-11U1SBK154238R11000.820100...250DRAF12-13U 1SBK154238R13000.820250...500DRAF12-14U1SBK154238R14000.8201.5355101524...60DRAF16-11U1SBK174238R11000.820100...250DRAF16-13U1SBK174238R13000.820250...500DRAF16-14U1SBK174238R14000.820DRAF+ TF42 to be ordered separately1SBC133005V001409
1SBC133004S0201ABB MOTOR PROTECTION AND CONTROL 9/9—DRAF09 ... DRAF16 enclosed direct-on-line startersUp to 7.5 kW and 10 hp, protected by thermal overload relaysAC operatedTF42 thermal overload relays to be ordered separatelySetting rangeShort-circuit protective device Trip classTy pe Order codeWeight(1 pce)Akg0.10 ... 0.130.5 A, Fuse type T10TF42-0.131SAZ721201R10050.1300.13 ... 0.171.0 A, Fuse type T10TF42-0.171SAZ721201R10080.1300.17 ... 0.231.0 A, Fuse type T10TF42-0.231SAZ721201R10090.1300.23 ... 0.311.0 A, Fuse type T10TF42-0.311SAZ721201R10130.1300.31 ... 0.412.0 A, Fuse type gG10TF42-0.411SAZ721201R10140.1300.41 ... 0.552.0 A, Fuse type gG10TF42-0.551SAZ721201R10170.1300.55 ... 0.744.0 A, Fuse type gG10TF42-0.741SAZ721201R10210.1300.74 ... 1.006.0 A, Fuse type gG10TF42-1.01SAZ721201R10230.1301.00 ... 1.306.0 A, Fuse type gG10TF42-1.31SAZ721201R10250.1301.30 ... 1.7010.0 A, Fuse type gG10TF42-1.71SAZ721201R10280.1301.70 ... 2.3010.0 A, Fuse type gG10TF42-2.31SAZ721201R10310.1302.30 ... 3.1010.0 A, Fuse type gG10TF42-3.11SAZ721201R10330.1303.10 ... 4.2020.0 A, Fuse type gG10TF42-4.21SAZ721201R10350.1304.20 ... 5.7020.0 A, Fuse type gG10TF42-5.71SAZ721201R10380.1305.70 ... 7.6035.0 A, Fuse type gG10TF42-7.61SAZ721201R10400.1307.60 ... 10.035.0 A, Fuse type gG10TF42-101SAZ721201R10430.13010.0 ... 13.040.0 A, Fuse type gG10TF42-131SAZ721201R10450.13013.0 ... 16.040.0 A, Fuse type gG10TF42-161SAZ721201R10470.13016.0 ... 20.063.0 A, Fuse type gG10TF42-201SAZ721201R10490.145Empty enclosure with push-buttonmm cable inlet/outlet suitable for IEC starter types–FR16AF-121SBN101337R10000.53Inch cable inlet/outlet suitable for UL starter types–FR16AF-12U1SBN101338R10000.53To be completed with AF contactor, TF42 thermal overload relay and CB5-10 (1SBN010013R1010) start contact block.TF422CDC231006V0013Empty enclosurewith push-button1SBC133004V001409
1SBC133005S02019/10ABB MOTOR PROTECTION AND CONTROL—DRAF09 ... DRAF16 enclosed direct-on-line startersControl supply wiring versions1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRAF1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRAF1L13L25L32T14T26T3L1 L2 L3IORA1A2Uc = VNUcUVA1A2Uc= UsDRAFA1A2Uc= UPhase-to-phasePhase-to-neutralSeparate supplyDR AF.. S DR AF..UDR AF.. NDR AF.. PWiring diagramPower circuit AC local control3-phase motorPhase-to-phaseSingle phase motorPhase-to-neutralSingle phase motorKM1A1A21314KM1AMRESETSTOP-7-8IFR19596IDRAF..PDRAF..NDRAF..SDRAF..UUsKM1: 5/L3KM1: 3/L2UsNDRAF..NDRAF..UDRAF..SDRAF..PAMRESETSTOPFR195961314-3-4KM1KM1A1+A2--+DRAF09, DRAF12, DRAF16IEC starter types - ISO M20Cable inletCable outletEnclosure topEnclosure bottom2 x ø 20 mm2 x ø 20 mm2 x ø 0.79"2 x ø 0.79"107 4.22"230 9.06"Ø 22.3 .88"60 2.36"8 .32"131.5 5.18"126.5 4.98"2 x Ø 5.5 .22"M5218 8.58"UL starter types - NPTCable inletCable outletEnclosure topEnclosure bottom1 x 3/4"1 x 3/4"1 x 1/2"1 x 1/2"Main dimensions mm, inches09
ABB MOTOR PROTECTION AND CONTROL 9/11ABB MOTOR PROTECTION AND CONTROL 9/11—Notes09
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/HF2.4-ROL-24VDC www.abb.com/productdetails/1SAT25000R1011or
—Electronic compact starters: HF range10/3 OverviewHF0.6, HF2.4, HF9 electronic compact starters10/8 Direct-on-line starter 10/8 Direct-on-line starter with emergency stop10/9 Reversing starter10/9 Reversing starter with emergency stop10/10 Technical data10/14 Technical diagramsABB MOTOR PROTECTION AND CONTROL 10/110
10/2ABB MOTOR PROTECTION AND CONTROL10
ABB’s electronic compact starter packs more functions into less space. The compact unit is just 22.5 mm wide and is suitable for three-phase motor loads up to 3 kW - 400 V AC. Direct-on-line and reversed starter with overload protection and emergency stop versions are available, making the range a perfect fit for high frequent and reliable long life switching of e.g. paper machines, conveyors, pumps, compressors and machine tools.Saving spaceUp to 90% less space required ABB's electronic compact starter saves cabinet space, and is especially effective for group mounting. The starter is just 22.5 mm wide and yet still provides motor starting function-alities with motor protection and safety embedded.Safety and protection Integrated safety function Protect your people with an emer-gency stop version that complies with SIL 3, PL e safety standards.Extend the life of your equipment and reduce maintenance costs with service lives that are ten times higher than electromechanical solutions.Easy to install Up to 75% reduced time in wiring Wiring time during installation is cut to a minimum with motor protection, reversing function and emergency stop already integrated in the product. With just one component to install, the risk of wiring errors is lower. Separate over-load protection is no longer needed.—Electronic compact starters: HF rangeA compact solution with great functionalityABB MOTOR PROTECTION AND CONTROL 10/310
Overload protectionABB offers three variants with wide setting ranges, using an electronic relay to protect the motor from overload. Protection against phase asymmetry and phase failure is also integrated.Emergency stopABB's HF safety range supports safety applications comply-ing to SIL3 and PL e safety level in combination with modular safety relays such as ABB's Sentry SSR10.Direct-on-lineABB's direct-on-line starter comes with a function that runs the motor in a forward direction. An integrated electronic overload relay also helps protect the motor.Reversing capabilityReversing functionality is already integrated in our hybrid starter. This results in avoiding wiring faults and additionally saving time and space.Direct-on-line and reversing function in only one product—Electronic compact startersAll-in-one: four functions in one starter10/4ABB MOTOR PROTECTION AND CONTROL10
Reset functionAfter the overload function has tripped, the electronic compact starter can be reset automatically, manually or remotely. The LEDs on the device are visualizing that an error has occurred. Additionally, a feedback relay will be activated.22.5 mm—Electronic compact startersFeatures and benefitsSpace-savingUsing an HF electronic compact starter saves space, especially when group-mounting units. With a width of just 22.5 mm and high func-tion density, the unit fits any control cabinet. Smaller footprints for more compact systems are also possible. Less wiringThe control circuit is connected on the upper side of the device with the main circuit on the underside. The all-in-one functionality reduces wiring, saving time and money – and reducing faults. Longer working lifeABB’s hybrid technology improves durability and re-duces power losses. Semiconductors switch on and off the unit and the relays remain active while the mo-tor is running. With a lifespan of 30 million cycles now achievable, maintenance costs are reduced.Group mounting and protection abilityCombine the HF-Starter with a MO132 up to 10 A. Protection against overload is realized with the HF-Starter and the MO132 protects against short circuits. Maximum space saving for group mounting is guaranteed. ABB MOTOR PROTECTION AND CONTROL 10/510
—Electronic compact startersHybrid technologyHybrid technology – efficient, durable and compact – is the key feature of this range. Smart use of semiconductors with a relay bypass eliminates the wearing of contact materials. A microcontroller ensures the precise interaction of the components, providing the smoother switching that helps extend its long lifespan.Wide setting range of motor Safety range:ATEX, SIL 3, PL e for selected referenceUpside-orientated control inputDrive-orientated main circuitDIN rail metal lockChange-over switchesHF9-ROLE-24 V DCHF9-ROL-24 V DC10/6ABB MOTOR PROTECTION AND CONTROL10
—Electronic compact starters - HF rangeHybrid technologyThanks to laser labeling and fewer connection points compared to conventionalsolutions, hybrid technology makes wiring easy. The screw connections for boththe control and the main circuit have an optimized angle to provide access.HF2.4-DOL-24 V DCReset: direct manual reset of device with button, convenient remote or automatic reset after thermal tripGroup mounting in confined spaces is no problemOnly one component for up to four functions leads to shorter wiring timeEasy-to-read starter status with LED indicators: Precise current setting with LED confirmationUsers can easily adjust the current and get visual feedback via the LEDs. For example, if 6.5 A is set, the lights confirm the selection:LEDCurrent APWRERRIadj.ON1.52.22.53.03.54.04.55.05.56.06.57.07. 58.08.59.022.5 mmNote: PWR: Control supply voltage, ERR : Error/Message, Iadj.: Current setting, ON: Motor is runningABB MOTOR PROTECTION AND CONTROL 10/710
The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 400 V AC. The integrated electronic overload protection with tripping class 10A has a wide setting range that enables just three models to cover all requirements. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3, in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1 all in combination with a safety relay like ABB's Sentry SSR10. The safety range is ATEX-certified.Rated operational current AC-53aRated operational powerAC-53aRated operational current AC-51Setting rangeFull load amps motor useType Order codeWeight(1 pce)AkWAAAkgDirect-on-line starter with overload protection0.60.18 (400V)0.60.075 ... 0.60.6HF0.6-DOL-24VDC1SAT112000R10110.2052.4 0.75 (400V)2.40.18 ... 2.4 2.4HF2.4-DOL-24VDC1SAT122000R10110.2186.53.00 (400V)9.01.5 ... 9.06.5HF9-DOL-24VDC1SAT142000R10110.206Direct-on-line starter with overload protection and emergency stop0.60.18 (400V)0.60.075 ... 0.60.6HF0.6-DOLE-24VDC1SAT113000R10110.2052.4 0.75 (400V)2.40.18 ... 2.4 2.4HF2.4-DOLE-24VDC1SAT123000R10110.2186.53.00 (400V)9.01.5 ... 9.06.5HF9-DOLE-24VDC1SAT143000R10110.206HF9-DOL-24VDCHF9-DOLE-24VDCMain dimensions mm, inches2CDC242003F0017HF0.6, HF2.4, HF9—HF0.6, HF2.4, HF9 electronic compact startersDirect-on-line starter2CDC241009V00162CDC241012V001610/8ABB MOTOR PROTECTION AND CONTROL10
The HF-ROL-range is used for forward and reverse running motors, as well as for switching non resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 400 V AC. The integrated electronic overload protection with tripping class 10A has a wide setting range that enables just three models to cover all requirements. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-ROLE safety range with emergency stop function. This offers Safety Integrity Level 3, in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1 all in combination with a safety relay like ABB's Sentry SSR10. The safety range is ATEX-certified.Rated operational current AC-53aRated operational powerAC-53aRated operational current AC-51Setting rangeFull load amps motor useType Order codeWeight(1 pce)AkWAAAkgReversing starter with no monitoring and no overload functionality6.53.00 (400V)9.0-6.5HF9-R-24VDC1SAT144000R10110.174Reversing starter with overload protection0.60.18 (400V)0.60.075 ... 0.60.6HF0.6-ROL-24VDC1SAT115000R10110.2172.40.75 (400V)2.40.18 ... 2.4 2.4HF2.4-ROL-24VDC1SAT125000R10110.2196.53.00 (400V)9.01.5 ... 9.06.5HF9-ROL-24VDC1SAT145000R10110.218Reversing starter with overload protection and emergency stop0.60.18 (400V)0.60.075 ... 0.60.6HF0.6-ROLE-24VDC1SAT116000R10110.2182.40.75 (400V)2.40.18 ... 2.4 2.4HF2.4-ROLE-24VDC1SAT126000R10110.2706.53.00 (400V)9.01.5 ... 9.06.5HF9-ROLE-24VDC1SAT146000R10110.289Main dimensions mm, inches2CDC242003F0017HF0.6, HF2.4, HF92CDC241013V0016HF9-R-24VDC2CDC241006V0016HF9-ROL-24VDC2CDC241003V0016HF9-ROLE-24VDC—HF0.6, HF2.4, HF9 electronic compact startersReversing starter ABB MOTOR PROTECTION AND CONTROL 10/910
Main circuit – Utilization characteristics according to IEC/ENTy peHF-DOL/ROLHF-DOLE/ROLEHF-RStandardsIEC/EN 60947-1, IEC/EN 60947-4-2 IEC/EN 60947-1, IEC/EN 60947-4-2, IEC/EN 61508, IS0 13849IEC/EN 60947-1, IEC/EN 60947-4-2Rated operational voltage Ue500 V ACOperational voltageMinimum42 V AC, Maximum550 V ACSetting rangesee ordering detailsRated frequency50/60 HzTrip class10ANumber of poles3Number of protected poles3Mechanical durability10000 cyclesElectrical durability30 Mio. cyclesRated impulse withstand voltage Uimp6 kVRated insulation voltage Ui500 VRated operational current Ie AC-51see ordering detailsRated operational current Ie AC-53asee ordering detailsRated uninterrupted current Iusee ordering details, Rated operational current IeOvervoltage categoryIIIDelay timeOff, minimum, switched off with pushbutton1 s1 s-Off, maximum, switched off with pushbutton3 s3 s-Off, typical, switched off via control input voltage30 ms30 ms30 msOff, maximum, switched off via control input voltage-HF0.6, HF2.4: 60 msHF9: 80 ms-Off, typical, switched off via supply voltage25 ms25 ms25 msOff, maximum, switched off via supply voltage-500 ms-Switch off timeBy phase failure1.8 s1.8 s-By phase asymmetry at 33%120 s120 s-By phase asymmetry at 67%1.8 s1.8 s-Overspeed trippingOperating thresholdHF9-DOL/ROL/DOLE/ROLE: >45 AResponse timeHF9-DOL/ROL/DOLE/ROLE: 2 sPower loss Minimum1.1 WMaximumHF0.6: 1.5 WHF2.4: 3.3 WHF9: 14.6 WSwitching frequency≤ 2 Hz; 120 starts/min; 7200 starts/hOvervoltage categoryIIIShort circuit protection with fuses and miniature circuit breakers according to IEC/EN 60947-4-2Order codeRated currentAC-53aIqProtection typeRated currentMaximum voltageType of coordinationAkAAV1SAT...0.6/2.4/6.550Fuse gG2541511SAT...0.6/2.4/6.535Fuse gG2550011SAT...0.6/2.4/6.51S203-16B165001For single and group mounting protection with manual motor starters according to IEC/EN 60947-4-2IqNumber of HF starterManual motor starterRated currentMaximum voltageType of coordinationkAHF0.6HF2.4HF09AV70921MO132-6.36.3415150921MO132-6.36.3415150921MO132-1010415135921MO132-6.36.35001351641MO132-10105001—HF0.6, HF2.4, HF9 electronic compact startersTechnical data10/10ABB MOTOR PROTECTION AND CONTROL10
Main circuit – Utilization characteristics according to UL/CSATy peHFStandardsUL 60947-1; UL 60947-4-2 Rated operational voltage500 V ACOperational voltageMinimum42 V ACMaximum550 V ACAmpere Rating UL/CSAsee ordering details, Full load amps motor useHorse power rating Nominal switching performance full load (power factor = 0.4)HF0.6: 0.4 hpHF2.4: 1.2 hpHF9: 3.0 hpNominal switching performance full load (power factor = 0.8)HF0.6: 0.6 hpHF2.4: 2.2 hpHF9: 6.1 hpFull loads Amps (FLA)see ordering detailsShort-circuit current rating (SCCR) (500 V AC, 30 A Class J or CC) 100 kAGeneral technical dataTy peHFUtilization categoryAC51, AC53aPollution degree2Phase loss sensitiveYesAmbient air temperature Operation-25 ... + 70 °COperation compensated-40 ... + 80 °CMounting positionPosition 1, load side bottomMounting in DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715,TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715Degree of protectionHousingIP20Main circuit terminalsIP20Control circuitTy peHFRated control circuit voltage Uc24 V DCInput voltage UinSwitching Threshold at Signal <0>-3 ... 9.6 VSwitching Threshold at Signal <1>19.2 ... 30 VInput current Ic3 mASupply circuitTy peHFRated control supply voltage Us24 V DCControl supply voltage19.2 ... 30 V DCRated control supply current Is0.04 AFor single or group protection following fuses can be used for UL application according to UL 60947-1/ -4-1Order codeRated currentIqProtection typeRated currentMaximum voltageType of coordinationAkAAV1SAT...0.6/2.4/6.5100Fuses class J or CC3050011SAT...0.6/2.4/6.55Fuse RK5205001—HF0.6, HF2.4, HF9 electronic compact startersTechnical data ABB MOTOR PROTECTION AND CONTROL 10/1110
Safety related dataTy peHF-DOLE/ROLEStandardsIEC/EN 60947-1, IEC/EN 60947-4-2, IEC/EN 61508, IS0 13849 Safe shut down for ambient temperature 40°C ... 60°CSafety integrity level acc. to IEC 61508-1SIL 3Performance level Up to eMean time to failure (MTTF) acc. to IEC60050-191-12-07DOLE: 43 yearsROLE: 39.3 yearsMean time to dangerous failure, motor protection447 yearsMean time to dangerous failure, safe shutdownDOLE: 518 yearsROLE: 517 yearsFailure in timeSafe, detectabled λsdDOLE: 543 FITROLE: 664 FITSafe, undetectable λsuDOLE: 852 FITROLE: 968 FITDangerous, detectable λdd218 FITDangerous, undetectable λduDOLE: 2.4 FITROLE: 2.67 FITSafe failure fraction (SFF)DOLE: 99.85%ROLE: 99.86%Diagnostic coverage (DC)DOLE: 98.91%ROLE: 98.79%Probability of dangerous failure per hour (PFH)DOLE: 2.4ROLE: 2.67Motor overload protection for ambient temperature 40°C ... 60°CSafety integrity level acc. to IEC 61508-1SIL 3Performance level Up to eMean time to failure (MTTF) acc. to IEC60050-191-12-07DOLE: 43 yearsROLE: 39.3 yearsMean time to dangerous failure, safe shutdownDOLE: 518 yearsROLE: 517 yearsFailure in timeSafe, detectabledDOLE: 517 FIT ROLE: 637 FITSafe, undetectableDOLE: 809 FIT ROLE: 870 FITDangerous, detectable239 FITDangerous, undetectable17 FITSafe failure fraction (SFF)DOLE: 98.92% ROLE: 99.03%Diagnostic coverageDOLE: 98.91%ROLE: 98.79%—HF0.6, HF2.4, HF9 electronic compact startersTechnical data10/1 2ABB MOTOR PROTECTION AND CONTROL10
Connecting characteristicsMain circuitTy peHFConnecting capacityRigid 1 x2 ... 2.5 mm²Flexible1 x2 ... 2.5 mm²Flexible with ferrule1 x2 ... 2.5 mm²Connecting capacity acc. to UL/CSARigid1 x24 ... 14 AWGFlexible1 x24 ... 14 AWGFlexible with ferrule1 x24 ... 14 AWGStripping length8 mmTightening torque0.5 ... 0.6 N·mTightening torque UL/CSA5 ... 7 in·lbTerminal typeScrew terminalsRecommended screw driverM3Control circuitTy peHFConnecting capacityRigid 1 x2 ... 2.5 mm²Flexible1 x2 ... 2.5 mm²Flexible with ferrule1 x2 ... 2.5 mm²Connecting capacity acc. to UL/CSARigid1 x24 ... 14 AWGFlexible1 x24 ... 14 AWGFlexible with ferrule1 x24 ... 14 AWGStripping length8 mmTightening torque0.5 ... 0.6 NmTightening torque UL/CSA5 ... 7 in.lbTerminal typeScrew terminalsRecommended screw driverM3—HF0.6, HF2.4, HF9 electronic compact startersTechnical data ABB MOTOR PROTECTION AND CONTROL 10/1310
Derating curvePlease consider the derating curves for group mounting with and without ≥22.5 mm distance and the overload protection for tripping class 10A. Side by sideWith 22.5 mm distanceHF9HF2.4HF0.6HF90123456789010203040506070Load current (A)Ambient temperature (°C)Derating curve HF range - electronic compact startersTripping characteristicsClass10 AClass10 A +20 %Class10 A -20 %0.101.0010.00100.001000.0010000.0012345678910Tripping time (s) Overcurrent factorTripping characteristics class 10A HF range - electronic compact starters—HF0.6, HF2.4, HF9 electronic compact startersTechnical diagrams10/14ABB MOTOR PROTECTION AND CONTROL10
—Notes ABB MOTOR PROTECTION AND CONTROL 10/1510
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/UMC100.3 DC www.abb.com/productdetails/1SAJ530000R0100or
ABB MOTOR PROTECTION AND CONTROL 11/1— Universal Motor Controller11/2 Overview 11/4 Functions 11/5 Applications 11/6 Components11/8 Ordering details 11/17 Technical data11/26 Dimensional drawings11
11/2ABB MOTOR PROTECTION AND CONTROL—Keep motors running 24 hours a daySecure uptime for your applicationABB's control products protect, control and automate critical business processes to make any application more productive. Rely on ABB as the partner to provide flexible, universal products. The Universal Motor Controller is an easy-to-use device that keeps your application running.Continuous operation The Universal Motor Controller (UMC) provides comprehensive, electronic motor protection. It ensures the motor is protected at all times, even if the control system or fieldbus breaks down. The precise electronic measurement system enables optimal utilization of the motors. Continuous trip behavior is supported by the long-term, high stability of the tripping charac-teristics. A comprehensive diagnostic system facilitates fault localization and rectification to help keep the system running and reduce downtime.Easy to installThe universal and modular structure of the UMC benefits the entire planning, design and maintenance process. It significantly reduces the amount of wiring required, as all the neces-sary protection, monitoring and control functions are integrated into a single device. The complete range of currents and communication: fieldbuses and Ethernet is covered in a sin-gle version, simplifying planning, inventory and servicing.Speed up your projects The system’s modular approach means it can expand and adapt to provide the optimal solu-tion for any situation, with an entry-level device that fulfills requirements for most applica-tions. All of the control functions required in the field are integrated and easy to configure via parameters. Application-specific control functions can be readily achieved using the pro-grammable logic system. 24711
ABB MOTOR PROTECTION AND CONTROL 11/3Optimal solution for motor control center applicationsABB's UMC is a flexible, modular and expandable motor management system for constant-speed, low-voltage range motors. Its most important tasks include motor protection, prevention of plant standstills and the reduction of down time. Early information relating to potential motor problems and swift diagnosis ensure continuous operation. The UMC is proven in a wide range of segments and in large projects using several thousand motor controllers.High plant availabilityThe UMC continuously transmits comprehensive operational, service and diagnostic data from the motor to the control system. This means faults are detected early on and their effects limited or even avoided entirely by timely countermeasures, increasing plant availability.Open communicationThe UMC is equipped with an interface for mounting a communication adapter. Selecting the relevant adapter enables the Universal Motor Controller to communicate using the popular fieldbuses, Profibus DP, DeviceNet or Modbus RTU. Communication via Ethernet networks is possible using the EtherNet/IPTM, Modbus TCP or Profinet protocol. The device can also be used without a communication interface as a stand-alone motor controller, such as in simple pump stations.Made in Germany, approved worldwideABB's Universal Motor Controller is engineered and manufactured in Germany. Approvals and certificates ensure the worldwide use of the product and with our long experience of project management, ABB gives you the best possible support.—Flexible motor management systemProven in use around the worldUnplanned or sudden motor stops can lead to costly faults in process sequences. ABB's Universal Motor Controllers stand for reliable motor protection, motor control, fieldbus and Ethernet communication and fault diagnosis. The UMC is used and trusted in countless applications with thousands of devices installed worldwide.The highlights•Compact design with integrated measuring system•Suitable for three-phase and single-phase motors•Standard device meets most feature requirements•Easy to extend for more advanced functionalities•Perfect solution for motor control centers (MCCs)•Worldwide approvals, including ATEX explosiveatmosphere certification•Fieldbus systems:Profibus DP, DeviceNet and Modbus RTU•Ethernet systems:Modbus TCP, Profinet IO, EtherNet/IPTM—Universal Motor Controller UMC100.3 with EtherNet/IPTM interface EIU32.011
1 1/4ABB MOTOR PROTECTION AND CONTROLMotor control•Integration of the most importantmotor control functions as ready,easily parameterizable blocks•Direct, reversing, star-delta starters•Pole changing/DahlanderActuator mode•Inching/jog mode•Adjustable restart strategy (loadshedding)Extended motor control•Freely programmable for special,application-specific controlfunctions•Simple adaptation to specifiedcontrol functions•Comprehensive library•Blocks for logic, counters, timing•Access to all I/Os and internalsignals—The functions in detailUniversal Motor Controller UMC100.3Motor protection•The UMC provides comprehensivemotor protection•Overload protection for single andthree-phase AC motors according toEN/IEC 60947-4-1•Rated motor currents from 0.24 to63 A with an integrated measuringsystem in a single version•Rated motor currents up to 850 Awith external current transformerCT4L/CT5L•Selectable tripping classes 5E, 10E,20E, 30E or 40E•Locked rotor protection•Phase failure, asymmetry andsequence protection•Under-/ overcurrent protection•Thermistor motor protection•Ground leakage detection – internallyor using CEM11-FBP.xxx sensors•Limitation of motor starts per time•Motor protection independent frombus communicationIn combination with voltage module VI150/VI155-FBP.0•Undervoltage/overvoltageprotection•Power supervision•Power factor supervision (cos j)•Voltage-based detection of phasefailure, asymmetry and sequenceControl stations and operation modes•Individual and flexible configuration•Remote operation via DCS or PLC•Local control via pushbuttons•Local control via operatings panelUMC100 -PAN•Force local via input signalMotor status/communicationQuick and comprehensive access to all data via control station, fieldbus, Eth-ernet and/or laptopOperating data•Motor status•Motor current•Thermal load•Maximum starting current•Run-up time•Time to trip•Remaining cool-down timeOperating data with voltage module VI150/VI155-FBP.0•Phase voltages•Active power•Apparent power•Power factor•EnergyService data•Counter for motor operating andstandstill hours•Number of starts•Number of overload trips•EnergyDiagnostic data•Comprehensive and detailed errormessages and warnings•Log for previous 16 errors•Plain text display on the control panelOpen communicationThe UMC is a basic device that can use various communication methods; the communication protocol is selected by plugging-on the right fieldbus commu-nication interface or connecting an Ethernet communication interface.11
ABB MOTOR PROTECTION AND CONTROL 11/5Cement factories• Robust and compact design• Several inputs, e.g. for querying the position of the damper limit switchesOil & gas, chemicals• Programmability• Ground fault monitoring• Undervoltage detection and configurable restart following voltage restart• Protection of motors in hazardous environments (ATEX)• Use in IT networksPulp and paper• Conformal coating• Modular design• Flexible communicationMining• Rated motor voltage of up to 1000 V• Can be used at altitudes of up to 5000 m• Ground fault monitoringWater supply and treatment• Pump controls as required• Underload detection with Cos j measuring• Pump cleaning applicationOthers• Steel plants• Ships—Main areas of applicationBenefit from ABB's Universal Motor Controller functionality in a wide variety of segments. Its flexibility, global recognition and comprehensive certification make it the top choice, no matter where you are.—01 —03—01 Water supply and treatment plants—02 Mining facilities—02—03 Cement plants11
11/6ABB MOTOR PROTECTION AND CONTROLUNIVERSAL MOTOR CONTROLLER UMC100.3Basic device, expandable with different modules•Voltage: max. 1000 V AC•Tripping classes: 5E, 10E, 20E, 30E, 40E in accordance with IEC/EN 60947-4-1•Built-in wide range measuring system, up to 63 A with one single version•Supply voltages: 24 V DC, 110-240 V AC/DC•Inputs: six digital inputs 24 V DC, one PTC input•Outputs: four digital outputsCOMMUNICATION INTERFACESDirectly connect a variety of communication interfaces to the UMC•Fieldbus interfaces:PDP32.0: Profibus DP, DNP31.0: DeviceNet, MRP31.0: Modbus RTU•Ethernet Interfaces:MTQ22-FBP.0: Modbus TCP, PNQ22-FBP.0: Profinet IO, EIU32.0: EtherNet/IPTMVOLTAGE MODULES VI150/VI155-FBP.0Voltage modules for determining phase voltages, power factor (cos j), active power, apparent power, energy, harmonic content (THD)•Supply voltage: 24 V DC•3-phase voltage measurement, up to 690 V in grounded and ungrounded networks•Voltage dependent protection functions—ComponentsThe basic device can be expanded with several modules: digital expansion modules, analog and temperature modules, voltage modules and a range of communication interfaces, guaranteeing full flexibility and covering a wide range of applications.123123451CaRDYERRVI150Diag1Cb 2Ca 2CbREADYInputs DI 230 VACRelay DO230VAC/1AERRORDIAG1CaRDYERRAI150DX122Diag1Cb 2Ca 2Cb1Ca 1Cb 2Ca 2CbL1L2 L3EIU32.0PDP32MRP31DNP32MAIN COMPONENTS11
ABB MOTOR PROTECTION AND CONTROL 11/7DIGITAL MODULES DX111/DX122-FBP.0Compact modules that increase the number of digital inputs and outputs• Supply voltage 24 V DC• Inputs: DX111 eight digital inputs 24 V DC, DX122 eight digital inputs 110/230 V AC• Outputs: four digital relay outputs, one configurable analog outputA control panel with a backlit LDC display and a choice of nine different languages ensures easy operation of the UMC, wherever you are. Sensors detect earth leakages; current transformers increase the current measuring range.ANALOG/TEMPERATURE MODULE AI111.0Expand the UMC with analog and temperature inputs• Supply voltage: 24 V DC • Three analog inputs• Configurable for temperature sensors and standard signals• Two modules AI111 can be connected to one UMCOPERATING PANEL UMC100-PANInstallation on the UMC or on the control cabinet door• Graphics-enabled, backlit display with three LEDs for status indication• Monitors all values, shows the status and diagnostic data• Speaks your language - choice of nine menu languages• USB-port for connection to a PC• Up/download of parameters and custom application logicCURRENT TRANSFORMERS CT4L/CT5LExtend the integrated measuring system for larger motors• For nominal motor currents > 63 A up to 850 A• Linear transformer, 3-phase with terminal block, designed for connecting leads Cu 2.5 mm2EARTH LEAKAGE SENSORS CEM11-FBP.XXXSummation current transformer for connecting to a digital input. Mounting with bracket on DIN busbar or wall• Four versions available with diameters from 20 mm to 120 mm• Simple residual current adjustment with rotary switch, including test position• Direct connected to a digital input of the motor controller• Flexible mounting45ACCESSORIES11
11/8 ABB MOTOR PROTECTION AND CONTROL—Universal Motor Controller UMC100.3 Ordering detailsDescriptionIntelligent motor management system for single and three-phase motors with Ie = 0.24 - 63 A in a single device. Compact housing with integrated current transformer for cable cross sec-tions up to 25 mm² (max. Ø with insulation 11 mm). Higher currents with additional external current transformer. Thermal overload protection according to EN/IEC 60947-4-1, selectable trip classes 5E, 10E, 20E, 30E, 40E. Some functions require an additional expansion module.• Motor protection functions: Over-/underload, over-/undercurrent, over-/undervoltage, rotor blocking, phase failure/imbalance/sequence Earth fault detection integrated or with external sensor CEM11-FBP.0 Hot motor protection with thermistor or temperature measurement• Motor control functions: Easily configurable motor control functions: direct, reverse, star-delta starter, pole-changing, overload relay, actuator mode, softstarter mode. Additionally free programmable application specific logic with function blocks• Service and diagnostic data: Operating hours, number of motor starts and overload trips, energy, standstill and operation hours supervision, motor status, faults and warnings, fault history (16 events) Motor current, phase voltages, thermal load, power factor (cos φ), active power, apparent power, energy, total harmonic distortion (THD).• Integrated I/Os: six digital inputs, one PTC input, four digital outputs. Maximum number of I/Os with expansion modules: 14 digital inputs, one PTC input, nine digital outputs, six analog inputs, one analog output• Communication interfaces for fieldbuses and Ethernet networks, Interface for operator panel UMC100-PAN, bus interface for connection of expansion modules• Versions for supply voltage 24 V DC and 110 – 240 V AC/DC, with ATEX approval and with ATEX plus conformal coating for applications in aggressive atmosphereDescriptionSupply voltageTy peOrder codePkg qtyWeight (1 pce) kgUniversal Motor Controller24 V DCUMC100.3 DC1SAJ530000R010010.275Universal Motor Controller110-240 V AC/DCUMC100.3 UC1SAJ530000R110010.315Universal Motor Controller, ATE X24 V DCUMC100.3 DC EX1SAJ530000R020010.275Universal Motor Controller, ATE X110-240 V AC/DCUMC100.3 UC EX1SAJ530000R120010.315Universal Motor Controller, ATEX conformal coating24 V DCUMC100.3 DC EX Coated1SAJ530000R021010.275Universal Motor Controller, ATEX conformal coating110-240 V AC/DCUMC100.3 UC EX Coated1SAJ530000R121010.315UMC100.32CDC341006V001411
ABB MOTOR PROTECTION AND CONTROL 11/9—Operating panel and cablesOdering detailsDescriptionOperating panel for Universal Motor Controller UMC100.3. Backlit graphical and multilingual full-text display, LEDs for status display. Assembly directly on UMC100.3 or on the control cabinet door via door mounting set (includes the connection cable).Functions• Monitor: Shows motor status, diagnostics and maintenance data• Operate: Start, stop, fault reset• Parametrize: Setting and changing of all motor and fieldbus parameters (password protection possible); all settings are performed in the selected language• Memory: Copy settings from one UMC100.3 to another• USB port for up/download of parameters and logic from PC with PBDTM softwareSupports nine languages: English, Finnish, French, German, Italian, Polish, Portuguese, Russian, SpanishThe protection cap UMC100-PAN increases the degree of protection for the operator panel from IP52 to IP54. It consists of transparent and flexible silicone material making it easy to read text messages, checking the LED status and use the buttons. It is removable to access the micro-USB port for parameter up/download.DescriptionTy peOrder codePkg qtyWeight (1 pce) kgOperating panelUMC100-PAN1SAJ590000R010310.047 0.7 m ext. cable with door mounting setUMCPAN-CAB.0701SAJ510003R000210.070 1.5 m ext. cable with door mounting setUMCPAN-CAB.1501SAJ510004R000210.088 3 m ext. cable with door mounting setUMCPAN-CAB.3001SAJ510002R000210.176 Protection cap for operating panelUMC100-PAN CAP1SAJ510005R0001100.013UMC100 -PAN2CDC341008V0014UMC100-PAN CAP2CDC341001V001711
11/10ABB MOTOR PROTECTION AND CONTROL—Expansion modulesOrdering detailsDescriptionUp to four expansion modules can be connected to one UMC100.3:•One digital expansion module DX111-FBP.0 or DX122-FBP.0•One voltage expansion moduleVI150-FBP.0 or VI155-FBP.0•Two analog/temperature expansionmodules AI111.0The supply voltage is 24 V DC; the 110-240 V AC/DC version of the UMC100.3 provides the 24 V DC supply for expansion modulesDX111-FBP.0I/O-expansion module with eight digital inputs 24 V DC, four relay outputs, one analog out-put 0/4-20 mA or 0...10 VDX122-FBP.0I/O-expansion module with eight digital inputs 110/230 V AC, four relay outputs, one analog output 0/4-0 mA or 0-10 V.VI15x-FBP.0Voltage modules for the determination of phase voltages, power factor (cos φ), apparent power, energy, total harmonic distortion (THD). For use in grounded networks (VI150-FBP.0) or in all networks (VI155-FBP.0), 150-690 V AC.AI111.0Analog/temperature expansion module, three inputs PT100, PT1000, KTY83, KTY84, NTC, 0 –10 V, 0/4-20 mA one or two modules AI111.0 can be connected to an UMC100.3.DescriptionTy peOrder codePkg qtyWeight (1 pce) kgI/O module for UMC100, 24 V DC digital inputDX111-FBP.01SAJ611000R01011 0.220 I/O module for UMC100, 110 - 230 V AC digital inputDX122-FBP.01SAJ622000R01011 0.220 3-phase voltage module for grounded networksVI150-FBP.01SAJ650000R010010.110 3-phase voltage module for all networksVI155-FBP.01SAJ655000R010010.110 Analog/temperature module 3 analog inputsAI111.01SAJ613000R010110.116 Connection cable UMC100 - I/O module, length 0.3 mUMCIO-CAB.0301SAJ691000R000110.011 Connection cable IO-module - IO-module, length 0.3 mIOIO-CAB.0301SAJ692000R000110.011Terminal set for UMC100.3 DC (spare parts)UMCTB-FBP.01SAJ929160R000110.043Terminal set for UMC100.3 UC (spare parts)UMCTB.11SAJ929160R000210.045DX111-FBP.0 2CDC341005S0009DX122-FBP.0 2CDC341004S0009VI150-FBP.02CDC341001S0011AI111.02CDC341001S001511
ABB MOTOR PROTECTION AND CONTROL 11/11 ABB MOTOR PROTECTION AND CONTROL 11/11—Fieldbus interfaces Ordering detailsDescriptionFieldbus communication interfaces enable the UMC100.3 to communicate via fieldbus.The interfaces can be used in two ways:• Mounted directly on an UMC100.3 – the interface is supplied from the UMC100.3 and no additional accessory is required• Mounted separately on a SMK3.0 adapter in the cable chamber of an MCC, the interface plugged on SMK3.0 requires a 24 V DC supply. Ready-made cables for applications in withdrawable systems are available, as well as terminal blocks for other cables: CDP18.150: Cable for use inside the drawer CDP24.150: Cable from SMK3.0 to drawer outside PDP32.0• Communication interface for PROFIBUS DP; supports the protocols PROFIBUS DP/V0 and V1• PNO-certified PROFIBUS slave• Data transfer rate up to 12 Mbit/s• Diagnostic LEDs• Fieldbus connection via nine-pole Sub-D connector or terminal blocks• GSD download from UMC100.3 webpage MRP31.0• Communication interface for Modbus RTU• Data transfer rate up to 57.6 kbit/s• Diagnostic LEDs• Fieldbus connection via terminal blocksDNP31.0• Communication interface for DeviceNet• ODVA-certified DeviceNet slave• Data transfer rate up to 500 kbit/s• Diagnostic LEDs• Fieldbus connection via terminal blocks• EDS download from UMC100.3 webpagePDR31.0• External active fieldbus termination for Profibus DP; the PDR31.0 needs to be mounted on a SMK3.0 adapter and supplied by 24 V DCDescriptionTy peOrder codePkg qtyWeight (1 pce) kgProfibus DP communication interfacePDP32.01SAJ242000R000110.050 Modbus RTU communication interface; terminal block for fieldbus connection includedMRP31.01SAJ251000R000110.039 DeviceNet communication interface; terminal block for fieldbus connection includedDNP31.01SAJ231000R000110.039Profibus DP active bus terminationPDR31.01SAJ243000R000110.030 PDP32.02CDC341015S0014MRP31.02CDC341016S0014DNP31.02CDC341017S0014PDR31.02CDC341018S001411
11/12ABB MOTOR PROTECTION AND CONTROL—Adapter and accessoriesOrdering detailsAdapter and ready-made cablesAdapter SMK3.0 for external mounting of a fieldbus or EtherNet/IP™ interface EIU32.0 outside a drawer. SMK3.0 can be mounted on a DIN-rail or fixed by screws. 24 V DC supply is required. Ready-made cables for inside and outside the drawer, including a terminal block on one side and open end on the other. Terminal blocks are also separately available for making own cables.DescriptionTy peOrder codePkg qtyWeight (1 pce) kgAdapter for separate mounting of a communication interface; terminal block for 24 V DC supply includedSMK3.01SAJ929600R000110.038 Cable for use inside drawer, length 1.5 mCDP18.1501SAJ929180R001510.060 Cable from SMK3.0 to drawer's outside, length 1.5 mCDP24.1501SAJ929240R001510.060 Terminal block 2-pole for SMK3.0 supply (spare parts)SMK3-X2.101SAJ929610R0001100.017 Terminal block 5-pole for SMK3.0 comm. (spare parts)SMK3-X1.101SAJ929620R0001100.041 5Separate wiring of the EtherNet/IPTM communication interface EIU32.042341CPD18.150EIU32.0CPD24.150Communication interface supply12335SMK3.05SMK3.02CDC341001S0015CDP18.1502CDC341007F0018PDP32.0 on SMK3.02CDC345008V0014EIU32.0 on SMK3.02CDC341010V001811
ABB MOTOR PROTECTION AND CONTROL 11/13—Ethernet interfacesOrdering detailsDescriptionEthernet communication interfaces enable the UMC100.3 to communicate via an Ethernet network. There are two types of in-terfaces:Interfaces for the connection of one to four Universal Motor Controllers UMC100.3: • MTQ22-FBP.0 for Modbus TCP• PNQ22-FBP.0 for Profinet IOInterface for a single universal motor con-troller UMC100.3:• EIU32.0 for EtherNet/IP™M TQ 2 2 - F B P. 0• Protocol Modbus TCP• For one to four UMC100.3• Master supervision with timeout control for up to four masters• Micro USB-port for configuration via PC (configuration software downloaded from UMC100.3 webpage)• Integrated Ethernet switch• Supports all network topologies• Ring topology with redundancy (MRP protocol)• Easy to use in withdrawable applications• No special Ethernet connectors required in MCCs• 24 V DC supply voltage• DIN-rail mountingPNQ22-FBP.0• Protocol Profinet IO• PNO-certified• For one to four UMC100.3 devices• Integrated Ethernet switch• Supports all network topologies• Ring topology with redundancy (MRP protocol)• Easy to use in withdrawable applications• No special Ethernet connectors required in MCCs• Fully integrated into ABB 800xA• Time-stamped events with ABB 800xA• 24 V DC supply voltage• DIN-rail mounting• GSDML downloaded from UMC100.3 webpageEIU32.0• Protocol EtherNet/IP™• ODVA-certified• For one motor controller UMC100.3• Mounting directly on an UMC100.3 (supplied by UMC100.3) or remotely on a SMK3.0 adapter (24 V DC supply required)• Integrated Ethernet switch• Supports all network topologies• DLR (Device Level Ring) function for redundancy• Easy to use in withdrawable applications• No special Ethernet connectors required in MCCs• EDS download from UMC100.3 webpageDescriptionTy peOrder codePkg qtyWeight (1 pce) kgEthernet Modbus TCP interfaceMTQ22-FBP.01SAJ260000R010010.172Ethernet Profinet IO interfacePNQ22-FBP.01SAJ261000R010010.172EtherNet/IPTM interfaceEIU32.01SAJ262000R010010.110EIU32.02CDC341009V0018PNQ22-FBP.02CDC341001S0014MTQ22-FBP.02CDC341003S001211
11/14ABB MOTOR PROTECTION AND CONTROL—Ready-made cables, terminal blocksOrdering details Ready-made cablesReady-made cables are available for application in withdrawable systems as well as for fixed installations. Cables include ready-mounted terminal blocks. All connectors are also available as spare parts for creating individual cable connections.Terminal blocks for making own cables are also available: MTQ22-FBP.0, PNQ22-FBP.0• CDP18.150 cable for useinside and outside a drawer• CDP23.150, CDP23.300 cables from Ethernet interface to UMC100.3EIU32.0• CDP18.150 cable for useinside a drawer• CDP24.150 cable for useoutside a drawer and connection to a SMK3.0 adapterUMC100.3, fix mounted application with solution MTQ22-FBP.0/PNQ22-FBP.024VDC0VPort 1Port 2Port 3RDYTCPLinkDataLinkDataMTQ22Port 4X1X2X3X4X5X6E1E2X6X7X8X9X5T1 T2CaCbDO RelayCC012RunDI 24VDOPower0V 24V0 ... 53Trip/RdyX6X7X8X9X5T1 T2CaCbDO RelayCC012RunDI 24VDOPower0V 24V0 ... 53Trip/RdyCDP23.xxxto X1to X4to X3to X2CDP23.xxxUMC100.3, withdrawable application with MTQ22 -FBP.0/PNQ22-FBP.024VDC0VPort 1Port 2Port 3RDYTCPLinkDataLinkDataMTQ22Port 4X1X2X3X4X5X6E1E2X6X7X8X9X5T1 T2CaCbDO RelayCC012RunDI 24VDOPower0V 24V0 ... 53Trip/RdyX6X7X8X9X5T1 T2CaCbDO RelayCC012RunDI 24VDOPower0V 24V0 ... 53Trip/RdyCDP18.150to X1to X4to X3to X2CDP18.150CDP18.150CDP18.150DescriptionTy peOrder codePkg qtyWeight (1 pce) kgCable for inside and outside drawer, length 1.5 mCDP18.1501SAJ929180R00151 0.060 Cable Ethernet interface - UMC100.3, length 1.5 mCDP23.1501SAJ929230R00151 0.100 Cable Ethernet interface - UMC100.3, length 3 mCDP23.3001SAJ929230R003010.160 Cable from SMK3.0 to drawer's outside, length 1.5 mCDP24.1501SAJ929240R001510.060 Terminal blocks for MTQ22/PNQ22 X1...X4ETHTB-FBP.41SAJ929200R00014 0.015 Terminal blocks for MTQ22/PNQ22 X1...X4ETHTB-FBP.501SAJ929200R0002500.015 CDP18.1502CDC341007F0018Terminal blocks ETHTB-FBP.xx2CDC341008F001811
ABB MOTOR PROTECTION AND CONTROL 11/15—Configuration softwareOrdering detailsFIM UMC EDITION configuration software for the UMC100.3 motor management system The FIM UMC Edition is based on the Field Device Integration (FDI) standard. This latest standard combines the benefits of both major former technologies, EDD and FDT/DTM.It is the perfect tool for configuration of the UMC100.3 universal motor controller in large applications in the process industry and also in smaller projects such as the water industry.The FIM UMC Edition is equipped with a high-performance graphical user interface which is quick to install. It scans, identifies and enables access to devices within three minutes.It provides effective basic functionality for configuration, diagnosis and maintenance, during commissioning, in the workshop or as second master in a Profibus network of a process control system. Overview of features• Online/offline configuration and parameterization of UMC100.3• Maximum number of tags is 2500• Reading parameterization and configuration information from the device • Online display of measuring, status and diagnostics data • Online operation and error acknowledgment • Creation of custom application logics • Archiving Supported languagesFIM basic package Chinese, English, GermanUMC100.3 Device Package Chinese, English, Spanish, German, Italian, Polish, Portuguese, RussianUMC100.3 Custom Application Editor EnglishSystem requirements• Windows 7 (64 bit)/Windows 8.1, Windows 10, admin rights• 10 GB storage space• Minimum of 1 GB RAMConnection to UMC100.3 can be done either via PROFIBUS DP or as a point-to-point connec-tionConnection to Profibus DP network: UTP22-FBP.0 Connection to UMC100.3: With micro-USB cable via control panel UMC100-PAN A trial version with limited functionality can be downloaded fromhttps://new.abb.com/control-systems/fieldbus-solutions/fimThe single user license in the FIM UMC Edition package upgrades the trial version to a full versionDescriptionTy peOrder codePkg qtyWeight (1 pce) kgUSB interface for Profibus networks UTP22-FBP.01SAJ924013R000110.261 FIM UMC Edition, Single user licensePBDTM-FBP.0 1SAJ925000R00011n.a.Configuration software exampleUTP22-FBP.02CDC341004F001111
11/16ABB MOTOR PROTECTION AND CONTROL—Earth fault monitors, current transformersOrdering detailsEarth fault monitors CEM11-FBP.xxx for use with the Universal Motor Controller UMC100.3The CEM11-FBP.xxx device monitors if the sum of the currents flowing through it is zero (factorial addition). If the sum is zero, no residual current is present. If the residual current is above an adjusted threshold value, the output signal of the CEM11-FBP.xxx changes. It can be used in motor feeders to detect leakage currents, as well as ground faults, caused for example by insulation breakdowns.• CEM11-FBP.xxx is connected to a digital input of the UMC100.3• Earth fault current threshold can be set in eight steps with a screwdriver• Test position for easy control of the wiringCEM11-FBP.xxx is delivered with adapters for DIN-rail or wall mounting.CEM-11.FBP.120 is for wall-mounting only.Current transformers for use with the Universal Motor Controller UMC100.3Linear type three-phase transformers, for use with the UMC100.3 and nominal motor cur-rents >63 A. Terminal blocks for conductors Cu 2.5 mm2 for wiring on the UMC100.3 side.Earth fault currentsThrough-hole diameterTy peOrder codePkg qtyWeight (1 pce) [mA]kg801), 300, 550, 750, 1000, 1200, 1500, 170020 mmCEM11-FBP.201SAJ929200R002010.130 1001), 500, 1000, 1400, 2000, 2400, 3000, 340035 mmCEM11-FBP.351SAJ929200R00351 0.200 1201), 1000, 2000, 2800, 4000, 4800, 6000, 680060 mmCEM11-FBP.601SAJ929200R006010.3303001), 2000, 4000, 5600, 8000, 9600, 12000, 13600120 mmCEM11-FBP.1201SAJ929200R012010.9401) Lower values have higher inaccuracyDescriptionRecommended current rangeTy peOrder codePkg qtyWeight (1 pce) kgCurrent transformer60...185 A ACCT4L185R/41SAJ929500R018511.600Current transformer180...310 A ACCT4L310R/41SAJ929500R03101 1.500 Current transformer300...500 A ACCT5L500R/41SAJ929501R050011.700Current transformer500...850 A ACCT5L850R/41SAJ929501R08501 1.900 UMC100-FBP.0 and FBP system accessories are being phased out. Please contact your local ABB contact for spare parts or retrofit solutions.CEM11-FBP.xxx2CDC345011F0008C T4 L 1 8 5 R /4 , C T4 L 3 10 R /42CDC341001S0012CT5L500R/4, CT5L850R/42CDC341002S001211
ABB MOTOR PROTECTION AND CONTROL 11/17—Universal Motor Controller UMC100.3Technical data*Please refer to the product manual for more detailed information.Control voltage circuitTy peUMC100.3 DCUMC100.3UCSupply voltage24 V DC (+30 % ... -20 %) (19,2 ... 31,2 V DC) including ripple110V - 240V AC/DC -15% / +10%Total power dissipation Conditions: all digital inputs high, all relay outputs activated*min. 3 Wmin P: 3.5 W / S: 8 WReverse polarity protectionyesnot relevantController unitLEDsRed: Motor has been tripped due to a thermal overload condition or another fault Yellow: Motor is running Green: Ready for operationDigital inputsNumber of digital inputs6 (DI0 ... D15) Type 1 accord. to EN 61131-2Supply for digital inputs24 V DCIsolationNoInput signal bounce suppressionTyp. 2 msSignal 0 range including ripple-31.2 ... +5 VSignal 1 range including ripple+15 ... +31.2 VInput current per channel (24 V DC)Typ. 6.0 mAInput resistor to 0 V3.9 k ΩCable lengthUnshielded max. 600 m Shielded max. 1000 mRelay outputsNumber of relay outputs3 x monostable with one common rootVoltage range of contacts12-250 V AC/DCLowest switched power for correct signals1 W or 1 VASwitching capacity per relay contact according to EN 60947-5-1 (electromagnetic load)AC-15 240 V AC max. 1.5 A AC-15 120 V AC max. 3 A DC-13 250 V DC max. 0.11 A DC-13 25 V DC max. 0.22 A DC-13 24 V DC max. 1 AShort circuit protection6 A gGRated impulse withstand voltage Uimp4 kVSwitching of inductive powerInductive loads need additional measures for spark suppressionDiodes for DC voltage and varistors / RC elements for AC voltage are suitable Some DC coil contactors contain rectifiers which suppress sparks perfectlyRelay contact service lifeMechanical 500 000 switching cycles Electrical (250 V AC): 0.5 A; 100 000 cycles 1.5 A 50 000 switchingInternal clearance and creepage distances relay contacts to 24 V circuits> 5.5 mm (safety insulation up to 250 V AC) (EN 60947-1, Pollution degree 2)Pollution degree terminals3Supply power down/up, behaviour: Valid for all motor control functions, except transparent and overload relayWhenever the supply voltage of the UMC is switched off and on, the starting of the motor needs a new RUN signal11
11/18ABB MOTOR PROTECTION AND CONTROL—Universal Motor Controller UMC100.3Technical dataTransistor outputTy peUMC100.3 DCUMC100.3 UCMax. output current200 mA50 mAShort circuit protectedYesYesOutput voltage if highUMC100.3 supply voltage, nominal 24 V DCnominal 24 V DCIsolationNoYes, to AC mainsThermistor motor protection (PTC - binary) type ABroken wire resistance > 4.8 kΩ Voltage at broken wires between terminals T1/T212 V DC (typ.)Response resistance3.4-3.8 kΩReset resistance1.5-1.65 kΩShort circuit resistance< 21 Ω Current at short circuit conditions1.5 mA (typ.)Response time800 msMax. cold resistance of PTC sensor chain< 1.5 kΩLine length2.5 mm2: 2 x 250 m1.5 mm2: 2 x 150 m0.5 mm2: 2 x 50 mIsolationNoEnvironmental and mechanical dataTy peUMC100.3 DCUMC100.3 UCMountingOn DIN-rail (EN 50022-35) or with four screws M4Mounting positionAnyDimensions (W x H x D)70 x 105 x 106 mmNet weight0.3 kg0.35 kgTightening torqueø 3.5 mm / 0.138 in ; 0.5 Nm, 4.5 in.lbWire size with wire end ferrule1 x 0.2-2.5mm2 (1 x 28 ... 12 AWG)Wire size with rigid1 x 0.2-2.5mm2 (1 x 28 ... 12 AWG)Tightening torque for screw mounting0.8 NmDegree of protectionIP20Temperature range storage-25 ... +70 °CTemperature range operation0 ... +60 °C with two output relays activated0 ... +60°C with two relay outputs activated and 24 V DC supply output loaded with 200 mA 0 ... +50°C with two relay outputs activated and 24 V DC supply output loaded with 400 mAPerformance dataReaction time UMC100 Dl to UMC100 Relay Output (incl. hardware delays)typ. 10 ms (Transparent Control Function)Reaction time UMCl00 Dl to DX111 Relay Output (incl. hardware delays)typ. 10 ms (Transparent Control Function)Reaction time from DX111 Dl to UMC100 Relay Ouput (incl. hardware delays)typ. 14 ms (Transparent Control Function)Number of supported function blocksSee 2CDC135014D02xx11
ABB MOTOR PROTECTION AND CONTROL 11/19—Digital expansion modules DX111-FBP.0, DX122-FBP.0Technical dataDigital inputsTy peDX111-FBP.0DX122-FBP.0Number of inputsEight inputs in two groups of common reference potential (One group with five inputs, one group with three inputs) Insulation: Type 1 acc. to EN 61131-1Eight inputs in two groups of common reference potential (One group with five inputs, one group with three inputs) Insulation: Type 2 acc. to EN 61131-1Input voltage24 V DC110 V AC ... 240 V ACInput delay6 ms typ.20 ms typ.Signal levels0 state - 31.2 ... + 5 V0 ... 40 V AC1 state + 15 ... + 31.2 V74 ... 265 V ACON current per channel6.0 mA typ. (24 V DC)10.0 mA typ. (230 V AC)Input resistance against 0 V3.9 kΩFrequency range45 ... 65 HzDigital outputNumber of digital outputs4 relay outputs with 2 common supplies (1DO0 & 1DO1 by 1DOC; 2DO2 & 2DO3 by 2DOC)Voltage switching capacity12 ... 250 V AC/DCLoad current via commonImax = 6 A gL / gG per common supply (1DOC, 2DOC)Minimum load for proper switching1 W or 1 VAContact wiring for inductive loadFree-wheeling diode for direct current, varistors/VDRs for alternating currentCurrent switching capacity per relayEN 60947-5-1240 V AC (AC-15) max. 1.5 A120 V AC (AC-15) max. 3 A250 V DC (DC-13) max. 0.11 A125 V DC (DC-13) max. 0.22 A24 V DC (DC-13) max. 1 ARelay contact lifetime> 500.000 switching cycles – mechanical, > 100.000 switching cycles – at 250 V AC, 0.5 A> 50.000 switching cycles – at 250 V AC, 1.5 AAnalog outputNumber of analog outputs1Connection type2-wire, for motor current indication on an external analog instrumentOutput rangesConfigurable: 0/4 ...20 mA or 0 ... 10 VCable specification< 30 m outside the control cabinet; >30 m if shieldedMax. output voltage10 VAccuracy< 5%Output load500 Ω max. if configured for 0/4 ... 20 mA output; 1 k Ω min. if configured for 0 ... 10 V outputResolution8 bitsShort-circuit detectionYes, if configured for 0 ... 10 V outputWire break detectionYes, if configured for 4 ... 20 mA outputInsulationnoneInterfacesInterface for I/O expansion1 for connection to UMC100 and/or other expansion modulesIntegrated diagnostic functionsGreen LED: Device ready for operation, Yellow LED: Wire break or short circuit indication Red LED: Error (loss of communication, failure, ...)—Digital expansion modules DX111-FBP.0, DX122-FBP.0Technical data11
11/20ABB MOTOR PROTECTION AND CONTROLGeneral dataTy peDX111-FBP.0DX122-FBP.0Supply voltage24 V DC (+ 30%, – 20%) (19.2 ... 31.2 V DC incl. residual ripple)Conductor cross sectionmax. 2 x 0.75 - 2.5 mm2 MountingSnap-on mounting on DIN rail, any mounting positionDimensions45 x 77 x 100 mm (without communication plug)Weight0.220 kgDegree of protectionIP20Temperature rangeStorage: -25 ... +70 °CStorage: -25 ... +70 °COperation: 0 ... +60 °COperation: 0 ... +55 °CApprovalsATEX, CCC, CE, cUL, EAC (other approvals on request) Shipping ABS, DNV, GL—Digital expansion modules DX111-FBP.0, DX122-FBP.0Technical data11
ABB MOTOR PROTECTION AND CONTROL 11/21—Voltage expansion modules VI150-FBP.0, VI155-FBP.0Technical dataTy peVI150-FBP.0VI155-FBP.0Applicationonly in grounded networksin grounded and ungrounded networksElectrical dataTy peVI150-FBP.0VI155-FBP.0Supply voltaqe24 V DC (+ 30 %, - 20 %) (19.2 ... 31.2 V DC including ripple)Current consumption relay enerqizedmax. 40 mAmax. 55 mAVoltaqe inputL1, L2, L3L1, L2, L3Overvoltaqe categoryIII in grounded networksII in ungrounded networksNominal voltaqe input range (phase to phase)90 - 690 V ACUimp8 kVAccuracy voltage+/- 2% in nominal input rangeAccuracy power factor+/- 3.5 % in range 0.4 ... 0.95, I > 0.75 AAccuracy real power kW+/- 5 % typ.Accuracy energy kWh+/- 5 % typ.Total Harmonic Distortion THDin %Rated operational voltage Ue690 V ACVoltage supply cablesconnection cables for voltage measurement may require additional cable protectionDigital outputNumber1 relay outputVoltage switching capacity12 ... 250 V AC/DCCurrent switching capacityEN 60947-5-1240 V AC (AC-15) max. 1.5 A120 V AC (AC-15) max. 3 A250 V DC (DC-13) max. 0.11 A125 V DC (DC-13) max. 0.22 A24 V DC (DC-13) max. 1 AMinimum load for proper switching1 W or 1 VAContact wiring for inductive loadFree-wheeling diode for DC, Varistors/VDRs for ACRelay contact lifetime> 500.000 switching cycles – mechanical> 100.000 switching cycles – at 250 V AC, 0.5 A> 50.000 switching cycles – at 250 V AC, 1.5 AInterfacesInterface for I/O expansion1 for connection to UMC100.3 and/or other expansion modulesIntegrated diagnostic functionsGreen LED: Device ready Yellow LED: Diagnostics Red LED: FaultGeneral dataTy peVI150-FBP.0VI155-FBP.0Conductor cross section2 x 0.75 - 2.5 mm2 max.MountingSnap-on mounting on DIN-rail, any mounting position Min. 10 mm distance left and right to the L1 and L3 terminals required for voltages > 230 / 400 VDimensions (W x H x D)22.5 x 77 x 100 mm (excl. communication connector)Weight0.110 kgDegree of protectionIP20Temperature rangeStorage: - 25 ... + 70 °C, operation:: 0 ... + 60 °COperation altitude above sea levelMax. 2000 mMax. 4000 m without deratingApprovalsATEX, CCC, CE, cUL,EAC (other approvals on request) Shipping: ABS, DNV, GL11
11/22ABB MOTOR PROTECTION AND CONTROLGeneralTy p eAI111.0MountingOn DIN rail (EN 50022-35) Mounting positionAnyDimensions (W x H x D)See dimensions of expansion modulesLEDs: Red/yellow/greenRed: Hardware error of module Yellow: Diagnosis available Green: Ready for operationSupply voltage24 V DC (+30 % ... -20 %) (19.2 ... 31.2 V DC) including rippleSupply currentMax. 40 mA (at 19.2 ... 31.2 V DC)Tightening torque for the communication terminals See section DX1xxTightening torque for the input, output and supply terminalsSee section DX1xxNet weight0.118 kg (0.260 lb)Degree of protectionIP20Temperature rangeStorage -25 ... +70 °C Operation 0 ... +60 °CMarks, ApprovalsCE, cULFurther in preparation. Ask your local sales representative for other marks/approvals.Functional isolation between anlog inputs and 24 V DC supply / communication interfaceYesIndiviual configuration of each analog inputYesUimp sensor analog inputs0.5 kVPollution degree terminals3Operation altitude above sea levelUp to 5000 mTemperature inputsTy p eAI111.0Type of connection2 or 3 wireNumber of input channels3 (one AI111.0) / 6 (two AI111.0)Type of temperature inputs (adjustable per channel)PT100 -50 °C...+400 °C PT100 -50 °C...+70 °C PT1000 -50 °C...+400 °C KTY83-110 -50 °C...+175 °CKTY84-130 -40 °C...+300 °CNTC +80...+160 °C [B75227-K333-A1]Accuracy at 20 °C (T20)≤ ± 2 KTemperature coefficient0.1 K per K deviation from T20Out of range detectionYesMax. cable lengthMax. cable resistance: 50R (single wire)[e.g. with copper wire 1.5 mm²: 1900 m cable length]Cable shieldingRecommended for up to 30 m and outside the switchgear cabinet; shielding mandatory for cables over 30 mUpdate rateTyp. 600 msSensor current (typ.)PT100 1 mA PT1000/KTY83/KTY84/NTC 0.2 mA—Analog/temperature expansion module AI111.0Technical data11
ABB MOTOR PROTECTION AND CONTROL 11/23—Analog/temperature expansion module AI111.0Technical dataAnalog inputsTy p eAI111.0Number of inputs3 (one AI111.0) / 6 (two AI111.0)Type of analog inputs (adjustable)0/4 mA - 20 mA / 0-10 VResolution15 BitMeasuring ranges Ty p eAI111.00...20 mA and 0...10 V0 .... 27648 dec (6C00 hex)4...20 mA0 .... 27648 dec (6C00 hex)Max. input current for 0/4-20 mA60 mA (destruction limit)Accuracy at 20 °C (T20)±1 % from full scale valueTemperature coefficient0.05 / K deviation from T20Input resistance≤ 300 Ohm at 0/4 -20 mA ≥ 10 k Ohm at 0-10 VWire break detectionIn operation mode: 4 mA - 20 mACable shieldingRecommended for up to 30 m and outside the switchgear cabinet; shielding mandatory for cables over 30 m11
11/24ABB MOTOR PROTECTION AND CONTROL—Fieldbus communication interfaces PDP32.0, MRP31.0, DNP31.0, PDR31.0Technical dataGeneral dataTy pePDP32.0MRP31.0DNP31.0PDR31.0Supply voltage24 V DC -20 ... +30% (19.2 ... 31.2 V DC) incl. ripple24 V DC -20% / - 20% (19.2 ... 31.2 V DC) incl. ripple24 V DC (11 ... 24,7 V DC) according to DeviceNet specification24 V DC -20 ... +30% (19.2 ... 31.2 V DC) incl. rippleCurrent consumption55 mA (excl. load on 5 V supply for termination resistors)Typ. 30 mATyp. 18.5 mA (from DeviceNet)28 mACommunication protocolProfibus DP-V0/DP-V1Modbus RTUDeviceNetActive Profibus DP terminationCertificateYes, PNO-Yes, ODVA-Fieldbus connection9-pole Sub-D connector or terminal blocksRemovable 5-pole terminal blocksRemovable 5-pole terminal blocks9-pole Sub-D connector or terminal blocksIntegrated termination resistorsNoNoNoYesPossible bus addresses (set via UMC100.3) 1 ... 1251 ... 1250 ... 63-Max. baud rate12 MBit/s57.6 kbaud500 kbaud-Isolated +5 V supply available for bus termination circuitry (X3 pins 5 and 6)30 mA max. ----Standards / directivesTy pePDP32.0MRP31.0DNP31.0PDR31.0EMC Directive2014/30/EC2014/30/EC2014/30/EC2014/30/ECRoHS Directive2011/65/EU2011/65/EU2011/65/EU2011/65/EUEnvironmental and mechanical dataTy pePDP32.0MRP31.0DNP31.0PDR31.0MountingOn UMC100.3 or SMK3.0 adapterOn UMC100.3 or SMK3.0 adapterOn UMC100.3 or SMK3.0 adapterOn SMK3.0 adapterMounting positionAnyAnyAnyAnyAmbient air temperatureOperation0 ... +60 °C0 ... +60 °C0 ... +60 °C0 ... +60 °CStorage-25 ... +70 °C-25 ... +70 °C-25 ... +70 °C-25 ... +70 °CVibration (sinusoidal) acc. to IEC/EN 60068-2-6 (Fc)0.7 g / 10 .... 150 Hz0.7 g / 10 .... 150 Hz0.7 g / 10 .... 150 Hz0.7 g / 10 .... 150 HzShock (half-sine) acc. to IEC/EN 60068-2-27 (Ea)15 g / 11 ms15 g / 11 ms15 g / 11 ms15 g / 11 msDegree of protection IP20IP20IP20IP20Pollution degree3333Operation altitude above sea level4000 m4000 m4000 m4000 mDuty cycle100 %100 %100 %100 %Weight0.051 kg0.039 kg0.042 kg0.047 kg11
ABB MOTOR PROTECTION AND CONTROL 11/25General dataTy peMTQ22-FBP.0PNQ22-FBP.0EIU32.0Supply voltage24 V DC -20 ... +30% (19.2 ... 31.2 V DC) incl. ripple24 V DC -20 ... +30% (19.2 ... 31.2 V DC) incl. ripple24 V DC -20 ... +30% (19.2 ... 31.2 V DC) incl. rippleCurrent consumptionMax. 180 mAMax. 180 mATyp 90 mA, max. 130 mATotal power dissipationMax. 3.5 WMax. 3.5 WTyp. 2.2 W, max. 2.5 WShort circuit protection at port 1 ... 4PTC resistorYes, PTC resistor-Connection between Ethernet interface and UMC100.3Max. 3 mMax. 3 mMax. 3 mCommunication protocolModbus TCPProfinet IOEtherNet/IPTMCertificate-Yes, PNOYes, ODVAIntegrated Ethernet switchYesYes-Supported bit rates10 / 100 Mbit/s100 Mbit/s10 / 100 Mbit/sNetwork redundancy protocolMRP client acc. to EN/IEC 62439-2MRP client acc. to EN/IEC 62439-2DLR (Device Level Ring)USB port For configuration via PC and software toolReservedReservedStandards / directivesTy peMTQ22-FBP.0PNQ22-FBP.0EIU32.0EMC Directive2014/30/EC2014/30/EC2014/30/EURoHS Directive2011/65/EU2011/65/EU2011/65/EUEnvironmental and mechanical dataTy peMTQ22-FBP.0PNQ22-FBP.0EIU32.0MountingDIN-railDIN-railDirectly on the UMC100.3 or remotely on SMK3.0 adapterMounting positionAnyAnyAnyAmbient air temperatureOperation0 ... +60 °C0 ... +60 °C0 ... +60 °CStorage-25 ... +70 °C-25 ... +70 °C-25 ... +70 °CDimensions (W x H x D)45 mm x 90 mm x 96 mm45 mm x 90 mm x 96 mm42.5 mm x 64 mm x 96 mmVibration (sinusoidal) acc. to IEC/EN 60068-2-6 (Fc)0.7 g / 10 ... 150 Hz0.7 g / 10 ... 150 Hz0.7 g / 10 ... 150 Hz (mounted on UMC100.3/SMK3.0)Shock (half-sine) acc. to IEC/EN 60068-2-27 (Ea)15 g / 11 ms15 g / 11 ms15 g / 11 msDegree of protection IP20IP20IP20Pollution degree333Operation altitude above sea level2000 m2000 m2000 m Duty cycle 100 %100 %100 %Weight0.172 kg0.172 kg0.110 kg—Ethernet communication interfaces MTQ22-FBP.0, PNQ22-FBP.0, EIU32.0 Technical data11
11/26ABB MOTOR PROTECTION AND CONTROL—Dimensional drawings11.6535.46326.8Ø 12Ø 2.722.857 0.20" 0.46" 1.39"Ø 0.11" 0.90" 2.48" 1.06" Ø 0.47" 2.24" 68 50.5 16 2.677"1.988"0.630"UMC100.3-PAN 57 2.24" 98 3.86"Ø 4.5 Ø 0.18" 70 90 106 100 106.7 2.76" 3.54" 4.17" 3.94"4.20"UMC100.3Universal Motor Controller UMC100.3Operating panelExpansion modulesDX111-FBP.0, DX122-FBP.0VI150-FBP.0, VI155-FBP.0 AI111.0VI150-FBP.0VI155-FBP.0AI111.0DX111-FBP.0, DX122-FBP.0UMC100-PAN CAPOperating panel protection cap53.04 2.09”20 0.79”66 2.6”1 0.04”20.3 0.8”17.8 0.7”70.55 2.78”85 3.46”UMC100.3-PAN drilling instruction109.5 4.31‘‘102 4.02‘‘100 3.94‘‘22.5 0.88‘‘45 1.77‘‘5.5 0.22‘‘1 0.039‘‘78 3.07‘‘78 3.07‘‘11
ABB MOTOR PROTECTION AND CONTROL 11/27—Dimensional drawings24VDC0VPort 1Port 2Port 3RDYTCPLinkDataLinkDataABBMTQ22Port 4X1X2X3X4X5X6E1E21.77"3.54"3.8"459096MTQ22-FBP.0PNQ22-FBP.0Ethernet communication interfacesxxx xxSMK3.0MRP31 / DNP31 22.5 89 64 99.7 0.886"3.504"2.520"3.925"xxx xxSMK3.0PDP32 / PDR31 22.5 89 105.2 64 0.886"3.504" 4.142"2.520"DNP31.0, MRP31.0, SMK3.0PDP32.0, PDR31.0Fieldbus communication interfaces99,7 3.93"100,7 3.96"64 2.52"NSEIU32MSDataE2LinkFEB1DataE1Link38 1.5"42.5 1.66"EIU32.011
11/28ABB MOTOR PROTECTION AND CONTROL—Dimensional drawings 3.86" 2.28" 7.56" 2.28" 3" Ø 0.24" 2.91" 0.83" 1.12" 0.83" 2.6" 2.17" 1.69" 58192 5876Ø 6742128.5 21 66 55 43 98 Ty peWidth (A)Depth (B)Height (C)Ø CEM11-FBP.2076.4 (3.01)30 (1.18)56 (2.20)20 (0.79)CEM11-FBP.3599.5 (1.38)30 (1.18)79 (3.11)35 (1.38)CEM11-FBP.60135 (5.31)38 (1.46)116 (4.57)60 (2.36)CEM11-FBP.120210 (8.27)38 (1.46)190 (7.48)120 (4.72)xBCAC T4 L 1 8 5 R /4 , C T4 L 3 10 R /4CT5L500R/4, CT5L850R/4Current transformerCE M 1 1- F B P. x xEarth fault monitor11
—Notes ABB MOTOR PROTECTION AND CONTROL 11/2911
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 www.abb.com/productdetails/1SBL137001R1310or
—Customer made Motor starting solution 12/2 Motor rated operational powers and currents12/3 Customer assembled motor starting solutions DOL and reversing starters protected by manual motor starters12/4 General12/6 Selection tables12/10 Wiring diagrams12/11 Main dimensions DOL starters protected by moulded-case circuit-breakers and overload relays12/18 General12/20 Selection tables12/24 Wiring diagrams Main dimensions, starter protected by12/25 MCCB including motor protection12/27 MCCB (magnetic only) and thermal overload relays12/30 MCCB (magnetic only) and electronic overload relays DOL and reversing starters protected by overload relays12/34 General12/36 Selection tables12/40 Switching frequency diagrams for overload relays12/41 Wiring diagrams Main dimensions, starter protected by 12/42 Thermal overload relays ABB MOTOR PROTECTION AND CONTROL 12/1Summary_5-1
—Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz).These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles.IECMotor nominal current: standardized values in grey(according to IEC 60947-4-1 Annex G)Motorpower220 V 230 V 240 V 380 V 400 V 415 V 440 V 500 V 660 V 690 VkWAAAAAAAAAA0.060.370.350.340.210.20.190.180.160.130.120.090.540.520.50 0.320.30.29 0.260.240.180.170.120.730.70.670.460.440.42 0.390.320.240.230.181110.630.60.580.530.480.370.350.251.61.51.40.90.850.820.740.680.510.490.372.01.91.8 1.21.11.110.880.670.640.552.72.62.51.61.51.4 1.31.20.910.870.753.53.33.22.01.91.81.71.51.151.11.14.94.74.52.82.72.62.42.21.71.61.56.66.363.83.63.5 3.22.92.22.12.28.98.58.15.24.94.74.33.92.92.8311.811.310.86.86.56.35.75.243.8415.71514.48.98.58.27.46.85.14.95.520.92019.2 12.111.511.110.19.276.77.528.22725.916.315.514.913.612.49.38.91139.73836.423.22221.219.317.613.412.81553.35148.930.5292825.42317.81718.563.86158.536.83533.7 30.72822212275.3726943.24139.535.93325.12430100969257.9555348.24433.53237120115110696664585340.83945146140134848077706449.147551771691621029793857859.6577524023022013913212711610681779029127826616816015414012897931103553403262051951881711561181131324184003832422302222021841401341605094874672952802702452241691622006376095843683503373072802122032507827487174534304143773442612503159839409015685405204734323273133551109106110176426105885354883703544001255120011507266906656055524184005001545147814168958508197456805154 935601727165215831000950916832760576551630192818441767111610601022929848643615710216420701984125311901147104395272169080024462340224314171346129711791076815780900276026402530159815181463133012149208801000304229102789176116731613146613391014970UL/CSAMotor nominal current: single and three phase(according to UL 60947-4-1A)Motorpower120 V 1-ph200 V 1-ph200 V 3-ph208 V 1-ph208 V 3-ph220-240 V 1-ph220-240 V 3-ph380- 415 V 3-ph440- 480 V 3-ph550- 600 V 3-phhpAAAAAAAAAA1/103––––1.5––––1/83.8––––1.9––––1/64.42.5–2.4–2.2––––1/45.83.3–3.2–2.9––––1/37.24.1–4–3.6––––1/29.85.62.55.42.44.92.2 1.3 1.1 0.93/413.87.93.77.63.56.93.2 1.8 1.6 1.31169.24.88.84.684.2 2.3 2.1 1.71-1/22011.56.9116.6106 3.3 3 2.422413.87.813.27.5126.8 4.3 3.4 2.733419.61118.710.6179.6 6.1 4.8 3.955632.217.530.816.72815.2 9.7 7.6 6.17-1/2804625.34424.24022 14 11 91010057.532.25530.85028 18 14 1115135–48.3–46.26842 27 21 1720––62.1–59.48854 34 27 2225––78.2–74.811068 44 34 2730––92–8813680 51 40 3240––120–114176104 66 52 4150––150–143216130 83 65 5260––177–169–154 103 77 6275––221–211–192 128 96 77100––285–273–248 165 124 99125––359–343–312 208 156 125150––414–396–360 240 180 144200––552–528–480 320 240 192250––––––604 403 302 242300––––––722 482 361 289350––––––828 560 414 336400––––––954 636 477 382450––––––1030–515 412500––––––1180 786 590 4721SBC101589S020112
—Customer assembled motor starting solutionsABB ExpertiseABB has acquired years of experience with respect to problems of coordination and is able to make a complete offer based on tests performed in its qualified laboratories. This offer covers 400 V AC, 500 V AC, 690 V AC networks.A complete database of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1), and UL 60947-4-1 between the branch circuit protective device and the motor starter is avail-able on the ABB Website.In the coordination tables the following short-circuit protection devices are recommended:• Case circuit-breakers (MCCBs)• Miniature circuit-breakers (MCBs)• Switch-disconnector-fuses (aM, gG and BS)• Manual motor starters (MMS).Select Optimized Coordination tool (SOC)Selected Optimized Coordination is a web tool for the selection of ABB products to be used in the following applications:• Motor starting and protection• Selectivity between protection devices• Back-up protection• Other devices protection.In order to guarantee the best performance and the longest lifetime, devices involved into the applications mentioned above (short-circuit protection devices, contactors, overload relays, softstarters, ...) need to be coordinated.• The coordination among devices cannot be determined directly: tests in power laboratories shall be carried out to qualify the coordination type at low fault and high fault currents, according to IEC or UL standards.• ABB coordination tables are the results of such tests and represent the ABB offerings in terms of motor starting and protection, selectivity, back-up and switch-disconnector protection.• In Selected Optimized Coordination all available ABB coordination tables are stored and easily accessible.Website access: http://applications.it.abb.com/SOC/Page/Selection.aspxHow to combine assemble and wire starter components The section "customer assembled motor stating solutions" in this catalog gives the components lists and wiring diagrams to assemble the most typical motor starting solutions. It covers direct-on-line Starters, reversing starters or star-delta starters protected with manual motor starters or with thermal overload relays for Type I or type II coordination for normal starting time.Note: In order to confirm your starter combination ratings according to ABB's lattest coordination test results, or to see other coordination of components please refer to the above mentioned SOC tool. SOC tool get constant updates and additions General remarks applicable to all tables• Each table is defined for a maximum ambient temperature of 40 °C. For higher temperatures, apply a derating factor according to the following rules:• Fuses: factor of 0.8 applied to In for an ambient temperature of 70 °C• MCCBs and MCBs: factor of 0.8 applied to In for an ambient temperature of 60 °C• The starter derating factor depends on the operating conditions of thermal overload relays:• Factor of 0.9 applied to In for an ambient temperature of 70 °C.• Each table is defined for motor currents: 3-phase motors, 4-pole• Normal starting means a starting time < 2 s. - Difficult starting means an accelerating time 10 s < ts < 30 s• Tripping classes of thermal overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10A and 10• Tripping classes of electronic overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10E, 20E, 30E selectable• In the tables with MCCBs, these are fitted with the magnetic relay alone. Setting is always carried out at > 12.3 Ie AC-3 so that the transient current peak occurring during starting does not lead to tripping.1SBC100497S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 12/312
—DOL and reversing starters protected by manual motor startersWith AF contactors - open type version in kit formApplicationFull voltage direct-on-line (DOL) starting and reversing starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal cur-rent.I/InC/Cn6543210710 306010080CII = currentC = torqueIn = nominal currentCn = nominal torqueCoordination types The contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:Ty p e 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate without being repaired or having parts replaced.Ty p e 2 : In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards. The risk of contacts light weld-ing is acceptable.Main Technical DataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VSwitching frequency≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting timeAmbient air temperatureClose to the deviceuse with MS116≤ 55 °Cuse with MS132, MS165, MS495≤ 60 °CDegree of protectionIP20I > DOL starterMS132-10 + BEA16-4 + AF09-30-10Mounting positionsPos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4Pos. 5Pos. 3Pos. 2Pos. 1Pos. 1 ± 30°+30°-30°Pos. 4DOL startersReversing starters1SFC101102V0001I > Reversing starterMS132-10 + BEA16-4 + BER16-4 + VEM4 + AF09-30-101SFC101105V00011SBC101917S0201 - Rev. B1 2/4ABB MOTOR PROTECTION AND CONTROL12
—DOL and reversing starters protected by manual motor startersWith AF contactors - open type version in kit formDirect-on-line starters You can easily assemble a direct-on-line starter by using the BEA..-4 connecting link 3-pole insulated. It is used to electrically and mechanically connect MS116, MS132 or MS165 manual motor starter and AF09 ... AF65 contactor, AC or DC operated.I > A2Reversing startersYou can easily assemble reversing starter thanks to our com-plete range of accessories:• BEA..-4 connecting link 3-pole insulated: it is used to elec-trically and mechanically connect MS116, MS132 or MS165 manual motor starter and AF09 ... AF65 contactor, AC or DC operated• For AF09 ... AF38, use VEM4 mechanical and electrical in-terlock set for reversing starter in 90 mm width. It in-cludes: - VM4 mechanical interlock unit including 2 fixing clips - VE4 electrical interlock block with A2-A2 connection.• For AF40 ... AF96, use VM96-4 mechanical interlock unit and additional auxiliary contact blocks for electrical inter-locking• BER..-4 connection set: it assures a safe and simple revers-ing connection between both contactor main terminals.Select now easily and quickly your starter in the following pages for coordination type 1 or 2 at 400 V, 50/60 Hz, Iq = 16 kA up to 18.5 kW and Iq = 50 kA up to 45 kW.Note: for direct mounting on 2 rails 35 mm of MS165 manual motor starter with AF40 ... AF65 contactors, BEA65-4 connecting link must be associated with BPR65-4 35 mm rail hook fixed on each contactor base. Starter combination using BPR65-4 are applicable for MS165 manufactured after week 31, 2016 (date code > 16214).I > For the full coordination tables, please visit our SOC tool :https://applications.it.abb.com/SOC/SelectivityMS Manual motor starterBEA Connecting linkAF09 ... AF65 ContactorVE4 Electrical interlock blockBEA Connecting linkMS Manual motor starterBER..-4 Connection setAF09 ... AF65 ContactorA2Fixing clipVM4 Mechanical interlock unit1SBC101917S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 12/512
12/6ABB MOTOR PROTECTION AND CONTROLCoordination type 1, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzManual motor startersContactorsAccessoriesI > CA4-10BEA..-4IECTy pe(1)Order codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc min. ... Uc max.(2)Ty pe(3)Order codeAllowed setting currentTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAAAV 50/60 HzV DCA0.060.2MS132-0.251SAM350000R10020.16...0.252.4424...6020...60 (5)AF09Z-30-10-111SBL136001R11100.25BEA16-41SBN081306T1000100...250 100...250AF09-30-10-131SBL137001R13100.090.3MS132-0.41SAM350000R10030.25...0.403.924...6020...60 (5)AF09Z-30-10-111SBL136001R11100.4100...250 100...250AF09-30-10-131SBL137001R13100.120.44MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250 100...250AF09-30-10-131SBL137001R13100.180.6MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250 100...250AF09-30-10-131SBL137001R13100.25 0.85MS132-1.01SAM350000R10050.63...1.0011.524...6020...60AF09Z-30-10-111SBL136001R11101100...250 100...250AF09-30-10-131SBL137001R13100.371.1MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250 100...250AF09-30-10-131SBL137001R13100.55 1.5MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250 100...250AF09-30-10-131SBL137001R13100.751.9MS132-2.51SAM350000R10071.60...2.5028.7524...6020...60AF09Z-30-10-111SBL136001R11102.5100...250 100...250AF09-30-10-131SBL137001R13101.12.7MS132-4.01SAM350000R10082.50...4.005024...6020...60AF09Z-30-10-111SBL136001R11104100...250 100...250AF09-30-10-131SBL137001R13101.53.6MS132-4.01SAM350000R10082.50...4.005024...6020...60AF09Z-30-10-111SBL136001R11104100...250 100...250AF09-30-10-131SBL137001R13102.24.9MS132-6.31SAM350000R10094.00...6.3078.7524...6020...60AF09Z-30-10-111SBL136001R11106.3100...250 100...250AF09-30-10-131SBL137001R131036.5MS132-101SAM350000R10106.30...10.015024...6020...60AF09Z-30-10-111SBL136001R11109100...250 100...250AF09-30-10-131SBL137001R131048.5MS132-101SAM350000R10106.30...10.015024...6020...60AF09Z-30-10-111SBL136001R11109100...250 100...250AF09-30-10-131SBL137001R13105.511.5MS132-121SAM350000R10128.00...12.018024...60 20...60AF12Z-30-10-111SBL156001R111012100...250 100...250AF12-30-10-13 1SBL157001R13107.515.5MS132-161SAM350000R101110.0...16.024024...60 20...60AF16Z-30-10-111SBL176001R111016100...250 100...250AF16-30-10-131SBL177001R13101122MS132-251SAM350000R101420.0...25.037524...60 20...60AF26Z-30-00-111SBL236001R110025BEA38-4+ CA4-101SBN082306T20001SBN010110R1010100...250 100...250AF26-30-00-13 1SBL237001R13001529MS132-321SAM350000R101525.0...32.048024...60 20...60AF30Z-30-00-111SBL276001R110032100...250 100...250AF30-30-00-131SBL277001R130018.535MS165-421SAM451000R101530.0...42.063024...6020...60AF40-30-00-111SBL347001R110040BEA65-4BPR65-4 (4)CA4-101SBN083406R10001SBN113405R1000100...250 100...250AF40-30-00-131SBL347001R13002241MS165-541SAM451000R101640.0...54.081024...6020...60AF52-30-00-111SBL367001R1100531SBN010110R1010100...250 100...250AF52-30-00-13 1SBL367001R13003055MS165-651SAM451000R101752.0...65.097524...6020...60AF65-30-00-111SBL387001R110065100...250 100...250AF65-30-00-13 1SBL387001R13003766MS495-751SAM550000R100857.0...75.097524...6020...60AF80-30-00-111SBL397001R110075100...250 100...250AF80-30-00-131SBL397001R13004580MS495-901SAM550000R100970.0...90.0117024...6020...60AF96-30-00-111SBL407001R110090100...250 100...250AF96-30-00-13 1SBL407001R1300(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to: - 15 kW, 400 V - AC-3 at 16 k A - 4 kW, 400 V - AC-3 at 50 k A.(2) For other control voltages, see "Voltage code table".(3) AF38 3-pole contactor can be selected for coordination type 1, 16 k A and 50 k A, 18.5 kW, 400 V - AC-3 (BEA65-4 available for AF40 ... AF65 only).(4) For direct mounting on 2 rails 35 mm of MS165 with AF40 ... AF65: BEA65-4 must be associated with BPR65-4 fixed on contactor base. Applicable for MS165 manufactured after week 31, 2016 (date code > 16114).(5) AF ... -11 not suitable for direct control by PLC-output.—DOL starters protected by MS manual motor startersCoordination type 11SBC101913S0201 - Rev. D12
ABB MOTOR PROTECTION AND CONTROL 12/7—DOL starters protected by MS manual motor startersCoordination type 2Coordination type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzManual motor startersContactorsAccessoriesI > CA4-10BEA..-4IECTy pe(1)Order codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc min. ... Uc max.(2)Ty pe (3)Order codeAllowed setting currentTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAAAV 50/60 HzV DC (6)A0.060.2MS132-0.251SAM350000R10020.16...0.252.4424...6020...60AF09Z-30-10-111SBL136001R11100.25BEA16-41SBN081306T1000100...250100...250AF09-30-10-131SBL137001R13100.090.3MS132-0.41SAM350000R10030.25...0.403.924...6020...60AF09Z-30-10-111SBL136001R11100.4100...250100...250AF09-30-10-131SBL137001R13100.120.44MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.180.6MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.250.85MS132-1.01SAM350000R10050.63...1.0011.524...6020...60AF09Z-30-10-111SBL136001R11101100...250100...250AF09-30-10-131SBL137001R13100.371.1MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.551.5MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.751.9MS132-2.51SAM350000R10071.60...2.5028.7524...6020...60AF09Z-30-10-111SBL136001R11102.5100...250100...250AF09-30-10-131SBL137001R13101.12.7MS132-4.01SAM350000R10082.50...4.005024...6020...60AF26Z-30-00-111SBL236001R11004BEA26-4+ CA4-101SBN082306T1000 1SBN010110R1010100...250100...250AF26-30-00-131SBL237001R13001.53.6MS132-4.01SAM350000R10082.50...4.005024...6020...60AF26Z-30-00-111SBL236001R11004100...250100...250AF26-30-00-131SBL237001R13002.24.9MS132-6.31SAM350000R10094.00...6.3078.7524...6020...60AF26Z-30-00-111SBL236001R11006.3100...250100...250AF26-30-00-131SBL237001R130036.5MS132-101SAM350000R10106.30...10.015024...6020...60AF26Z-30-00-111SBL236001R110010100...250100...250AF26-30-00-131SBL237001R130048.5MS132-101SAM350000R10106.30...10.015024...6020...60AF26Z-30-00-111SBL236001R110010100...250100...250AF26-30-00-131SBL237001R13005.511.5MS132-121SAM350000R10128.00...12.018024...6020...60AF26Z-30-00-111SBL236001R110012BEA38-4+ CA4-101SBN082306T20001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R13007.515.5MS132-161SAM350000R101110.0...16.024024...6020...60AF30Z-30-00-111SBL276001R110016100...250100...250AF30-30-00-131SBL277001R13001122MS132-251SAM350000R101420.0...25.037524...6020...60AF30Z-30-00-111SBL276001R110025100...250100...250AF30-30-00-131SBL277001R13001529MS132-321SAM350000R101525.0...32.048024...6020...60AF30Z-30-00-111SBL276001R110032100...250100...250AF30-30-00-131SBL277001R130018.535MS165-421SAM451000R101530.0...42.063024...6020...60AF40-30-00-111SBL347001R110040BEA65-4BPR65-4 (5)1SBN083406R10001SBN113405R1000100...250100...250AF40-30-00-131SBL347001R13002241MS165-541SAM451000R101640.0...54.081024...6020...60AF52-30-00-111SBL367001R110053CA4-101SBN010110R1010100...250100...250AF52-30-00-131SBL367001R13003055MS165-651SAM451000R101752.0...65.097524...6020...60AF65-30-00-111SBL387001R110065100...250100...250AF65-30-00-131SBL387001R13003766MS495-751SAM550000R100857.0...75.097524...6020...60AF80-30-00-111SBL397001R110075100...250100...250AF80-30-00-131SBL397001R13004580MS495-901SAM550000R100970.0...90.0117024...6020...60AF96-30-00-111SBL407001R110090100...250100...250AF96-30-00-131SBL407001R1300(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to - 15 kW 400V - AC-3 at 16 k A - 4 kW, 400 V - AC-3 at 50 k A.(2) For other control voltages, see "Voltage code table".(3) AF26 3-pole contactor can be selected for coordination type 2, 16 k A, 7.5 kW, 400 V - AC-3. AF38 3-pole contactor can be selected for coordination type 2, 16 k A and 50 k A, 18.5 kW, 400 V - AC-3 (BEA65-4 available for AF40 ... AF65 only).(4) BEA26-4 should be selected with MS116-12 ... MS116-16 and AF26 ... AF38. BEA38-4 can only be selected with MS116-20 ... MS116-32.(5) For direct mounting on 2 rails 35 mm of MS165 with AF40 ... AF65: BEA65-4 must be associated with BPR65-4 fixed on contactor base. Applicable for MS165 manufactured af-ter week 31, 2016 (date code > 16114).(6) AF ... -11 not suitable for direct control by PLC-output.1SBC101914S0201 - Rev. D12
Coordination type 1, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzManual motor startersContactorsAccessoriesI > + BER..-4VEM4CA4-10BEA..-4IECTy pe(1)Order codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc min. ... Uc max.(2)Ty pe(3)Order codeAllowed setting currentTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAAAV 50/60 HzV DCA0.060.2MS132-0.251SAM350000R10020.16...0.252.4424...6020...60AF09Z-30-10-111SBL136001R11100.25++BEA16-4BER16-4VEM41SBN081306T10001SBN081311R10001SBN030111R1000100...250100...250AF09-30-10-131SBL137001R13100.090.3MS132-0.41SAM350000R10030.25...0.403.924...6020...60AF09Z-30-10-111SBL136001R11100.4100...250100...250AF09-30-10-131SBL137001R13100.120.44MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.180.6MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.250.85MS132-1.01SAM350000R10050.63...1.0011.524...6020...60AF09Z-30-10-111SBL136001R11101100...250100...250AF09-30-10-131SBL137001R13100.371.1MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.551.5MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.751.9MS132-2.51SAM350000R10071.60...2.5028.7524...6020...60AF09Z-30-10-111SBL136001R11102.5100...250100...250AF09-30-10-131SBL137001R13101.12.7MS132-4.01SAM350000R10082.50...4.005024...6020...60AF09Z-30-10-111SBL136001R11104100...250100...250AF09-30-10-131SBL137001R13101.53.6MS132-4.01SAM350000R10082.50...4.005024...6020...60AF09Z-30-10-111SBL136001R11104100...250100...250AF09-30-10-131SBL137001R13102.24.9MS132-6.31SAM350000R10094.00...6.3078.7524...6020...60AF09Z-30-10-111SBL136001R11106.3100...250100...250AF09-30-10-131SBL137001R131036.5MS132-101SAM350000R10106.30...10.015024...6020...60AF09Z-30-10-111SBL136001R11109100...250100...250AF09-30-10-131SBL137001R131048.5MS132-101SAM350000R10106.30...10.015024...6020...60AF09Z-30-10-111SBL136001R11109100...250100...250AF09-30-10-131SBL137001R13105.511.5MS132-121SAM350000R10128.00...12.018024...60 20...60AF12Z-30-10-111SBL156001R111012100...250100...250AF12-30-10-131SBL157001R13107.515.5MS132-161SAM350000R101110.0...16.024024...60 20...60AF16Z-30-10-111SBL176001R111016100...250100...250AF16-30-10-131SBL177001R13101122MS132-251SAM350000R101420.0...25.037524...60 20...60AF26Z-30-00-111SBL236001R110025+++ 2xBEA38-4BER38-4VEM4CA4-101SBN082306T20001SBN082311R10001SBN030111R10001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R13001529MS132-321SAM350000R101525.0...32.048024...60 20...60AF30Z-30-00-111SBL276001R110032100...250100...250AF30-30-00-131SBL277001R130018.535MS165-421SAM451000R101530.0...42.063024...6020...60AF40-30-00-111SBL347001R110040+ 2x+++ 2x+ 2xBEA65-4BPR65-4 (4)BER65-4VM96-4CA4-10CA4-011SBN083406R10001SBN113405R10001SBN083411R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF40-30-00-131SBL347001R13002241MS165-541SAM451000R101640.0...54.081024...6020...60AF52-30-00-111SBL367001R110053100...250100...250AF52-30-00-131SBL367001R13003055MS165-651SAM451000R101752.0...65.097524...6020...60AF65-30-00-111SBL387001R110065100...250100...250AF65-30-00-131SBL387001R13003766MS495-751SAM550000R100857.0...75.097524...6020...60AF80-30-00-111SBL397001R110075++ 2x+ 2xBER96-4VM96-4CA4-10CA4-011SBN083911R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF80-30-00-131SBL397001R13004580MS495-901SAM550000R100970.0...90.0117024...6020...60AF96-30-00-111SBL407001R110090100...250100...250AF96-30-00-131SBL407001R1300(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to: - 15 kW, 400 V - AC-3 at 16 k A - 4 kW, 400 V - AC-3 at 50 k A.(2) For other control voltages, see "Voltage code table".(3) AF38 3-pole contactor can be selected for coordination type 1, 16 k A and 50 k A, 18.5 kW, 400 V - AC-3 (BEA65-4 available for AF40 ... AF65 only).(4) For direct mounting on 2 rails 35 mm of MS165 with AF40 ... AF65: BEA65-4 must be associated with BPR65-4 fixed on each contactor base. Applicable for MS165 manufactured after week 31, 2016 (date code > 16114).(5) AF ... -11 not suitable for direct control by PLC-output.—Reversing starters protected by MS manual motor startersCoordination type 11SBC101915S0201 - Rev. C12/8 ABB MOTOR PROTECTION AND CONTROL12
Coordination type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzManual motor startersContactorsAccessoriesI > + BER..-4VEM4CA4-10BEA..-4IECTy pe(1)Order codeCurrent setting rangeMagnetic tripping current Rated control circuit voltage Uc min. ... Uc max.(2)Ty pe(3)Order codeAllowed setting currentTy pe(4)Order codeAC-3, 400 VRated operationalpowercurrentkWAAAV 50/60 HzV DCA0.060.2MS132-0.251SAM350000R10020.16...0.252.4424...6020...60AF09Z-30-10-111SBL136001R11100.25++BEA16-4BER16-4VEM41SBN081306T10001SBN081311R10001SBN030111R1000100...250100...250AF09-30-10-131SBL137001R13100.090.3MS132-0.41SAM350000R10030.25...0.403.924...6020...60AF09Z-30-10-111SBL136001R11100.4100...250100...250AF09-30-10-131SBL137001R13100.120.44MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.180.6MS132-0.631SAM350000R10040.40...0.636.1424...6020...60AF09Z-30-10-111SBL136001R11100.63100...250100...250AF09-30-10-131SBL137001R13100.250.85MS132-1.01SAM350000R10050.63...1.0011.524...6020...60AF09Z-30-10-111SBL136001R11101100...250100...250AF09-30-10-131SBL137001R13100.371.1MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.551.5MS132-1.61SAM350000R10061.00...1.6018.424...6020...60AF09Z-30-10-111SBL136001R11101.6100...250100...250AF09-30-10-131SBL137001R13100.751.9MS132-2.51SAM350000R10071.60...2.5028.7524...6020...60AF09Z-30-10-111SBL136001R11102.5100...250100...250AF09-30-10-131SBL137001R13101.12.7MS132-4.01SAM350000R10082.50...4.005024...6020...60AF26Z-30-00-111SBL236001R11004+++ 2xBEA26-4BER38-4VEM4CA4-101SBN082306T10001SBN082311R10001SBN030111R10001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R13001.53.6MS132-4.01SAM350000R10082.50...4.005024...6020...60AF26Z-30-00-111SBL236001R11004100...250100...250AF26-30-00-131SBL237001R13002.24.9MS132-6.31SAM350000R10094.00...6.3078.7524...6020...60AF26Z-30-00-111SBL236001R11006.3100...250100...250AF26-30-00-131SBL237001R130036.5MS132-101SAM350000R10106.30...10.015024...6020...60AF26Z-30-00-111SBL236001R110010100...250100...250AF26-30-00-131SBL237001R130048.5MS132-101SAM350000R10106.30...10.015024...6020...60AF26Z-30-00-111SBL236001R110010100...250100...250AF26-30-00-131SBL237001R13005.511.5MS132-121SAM350000R10128.00...12.018024...60 20...60AF26Z-30-00-111SBL236001R110012+++ 2xBEA38-4BER38-4VEM4CA4-101SBN082306T20001SBN082311R10001SBN030111R10001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R13007.515.5MS132-161SAM350000R101110.0...16.024024...60 20...60AF30Z-30-00-111SBL276001R110016100...250100...250AF30-30-00-131SBL277001R13001122MS132-251SAM350000R101420.0...25.037524...60 20...60AF30Z-30-00-111SBL276001R110025100...250100...250AF30-30-00-131SBL277001R13001529MS132-321SAM350000R101525.0...32.048024...60 20...60AF30Z-30-00-111SBL276001R110032100...250100...250AF30-30-00-131SBL277001R130018.535MS165-421SAM451000R101530.0...42.063024...6020...60AF40-30-00-111SBL347001R110040BEA65-41SBN083406R10001SBN113405R10001SBN083411R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300+ 2xBPR65-4 (5)2241MS165-541SAM451000R101640.0...54.081024...6020...60AF52-30-00-111SBL367001R110053+ BER65-4100...250100...250AF52-30-00-131SBL367001R1300+VM96-43055MS165-651SAM451000R101752.0...65.097524...6020...60AF65-30-00-111SBL387001R110065+ 2xCA4-10100...250100...250AF65-30-00-131SBL387001R1300+ 2xCA4-013766MS495-751SAM550000R100857.0...75.097524...6020...60AF80-30-00-111SBL397001R110075BER96-41SBN083911R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300+VM96-44580MS495-901SAM550000R100970.0...90.0117024...6020...60AF96-30-00-111SBL407001R110090+ 2xCA4-10100...250100...250AF96-30-00-131SBL407001R1300+ 2xCA4-01(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to - 15 kW 400V - AC-3 at 16 k A - 4 kW, 400 V - AC-3 at 50 k A.(2) For other control voltages, see "Voltage code table".(3) AF26 3-pole contactor can be selected for coordination type 2, 16 k A, 7.5 kW, 400 V - AC-3. AF38 3-pole contactor can be selected for coordination type 2, 16 k A and 50 k A, 18.5 kW, 400 V - AC-3 (BEA65-4 available for AF40 ... AF65 only).(4) BEA26-4 should be selected with MS116-12 ... MS116-16 and AF26 ... AF38. BEA38-4 can only be selected with MS116-20 ... MS116-32.(5) For direct mounting on 2 rails 35 mm of MS165 with AF40 ... AF65: BEA65-4 must be associated with BPR65-4 fixed on each contactor base. Applicable for MS165 manufactured after week 31, 2016 (date code > 16114).(6) AF ... -11 not suitable for direct control by PLC-output.—Reversing starters protected by MS manual motor startersCoordination type 21SBC101916S0201 - Rev. D ABB MOTOR PROTECTION AND CONTROL 12/912
IKM1:5/L3UsO3334Q14344Q1UsNKM1:3/L213KM114A2A1KM133344344Q1OKM113KM114A1A2UsNKM1:3/L2KM1:5/L3UsIQ11314KM1A1A21/L13/L25/L32/T14/T26/T3I> I>I>5/L33/L21/L12/T14/T26/T3Q133344344WVU~M4434334313141/L13/L25/L32/T14/T26/T3I> I>I>5/L33/L21/L12/T14/T26/T3VU~M—DOL and reversing starters protected by manual motor startersWith AF contactors - open type version in kit formWiring diagramsPower circuit1-phaseAC or DC local controlAC or DC remote controlDirect-on-line startersNote: coil Uc 12-20 V DC : A1+, A2-33344344KM2A1A21/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T3I> I>I>Q12/T14/T26/T31/L13/L25/L3UVW~M.4KM2.3.4KM1.3OII IQ13433(3)(1)(2)(2)A201A2KM2KM14344Q1 UsNKM2:3/L2KM2:5/L3 Us01II I.4KM2.3.4KM1.3O3334Q14344Q1(3)(1)(2)(2)KM2A201A2KM2:5/L3 UsUsNKM2:3/L2KM101A2KM1A122KM221A2A1KM222KM121A2KM1A122KM221A2A1KM222KM121Reversing startersPower circuitAC or DC local controlAC or DC remote controlNote: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection (Except for coil Uc 12-20 V DC : use VM4 with CA4). - coil Uc 12-20 V DC : A1+, A2-With VMWith VMWith VEM4With VEM41SBC101918S020112/10ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MS116 manual motor startersWith AF contactors - open type version in kit formNote: contactor lateral distance to grounded component 2 mm 0.08" min.Coordination tables for MS166 available is our SOC tool :https://applications.it.abb.com/SOC/SelectivityMS116-0.16 ... MS116-16 + BEA16-4+ AF09, AF12, AF16 MS116-0.16 ... MS116-16 + BEA26-4+ AF26, AF30, AF38 186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"192 7.56"45 1.77"752.95"81.1 3.19"72.2 2.84"5.50.22"45 1.77"5.5 0.22"86 3.39"10 0.39"35 mm EN/IEC 60715186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"5.5 0.22"100.39"77 3.03"188 7.40"45 1.77"752.95"80.1 3.15"70 2.76"35 mm EN/IEC 607155.50.22"45 1.77"755.5 0.22"86 3.39"10 0.39"188 7.40"45 1.77"2.95"80.1 3.15"70 2.76"35 mm EN/IEC 607155.50.22"45 1.77"186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"Main dimensions mm, inches1SBC101919S0201 ABB MOTOR PROTECTION AND CONTROL 12/1112
—DOL starters protected by MS132 manual motor startersWith AF contactors - open type version in kit formMS132-12 ... MS132-25 + BEA16-4+ AF09, AF12, AF16MS132-0.16 ... MS132-10 + BEA26-4+ AF26, AF30, AF3881.3 3.20"72.4 2.85"5.50.22"45 1.77"35 mm EN/IEC 60715188 7.40"752.95"10 0.39"45 1.77"5.5 0.22"86 3.39"186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"MS132-0.16 ... MS132-10 + BEA16-4+ AF09, AF12, AF16MS132-12 ... MS132-32 + BEA38-4+ AF26, AF30, AF38186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"192 7.56"45 1.77"752.95"81.1 3.19"72.2 2.84"5.50.22"45 1.77"5.5 0.22"10 0.39"77 3.03"35 mm EN/IEC 60715186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"81.3 3.20"72.4 2.85"5.50.22"45 1.77"5.5 0.22"10 0.39"77 3.03"35 mm EN/IEC 60715188 7.40"45 1.77"752.95"186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"192 7.56"45 1.77"752.95"81.1 3.19"72.2 2.84"5.50.22"45 1.77"5.5 0.22"86 3.39"10 0.39"35 mm EN/IEC 60715186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"192 7.56"45 1.77"752.95"81.1 3.19"72.2 2.84"5.50.22"45 1.77"5.5 0.22"86 3.39"10 0.39"35 mm EN/IEC 60715Main dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.1SBC101923S0201 - Rev. A12/12ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MS165 manual motor startersWith AF contactors - open type version in kit formMain dimensions mm, inchesMS165 + BEA65-4+ AF40, AF52, AF65 MS165 + BEA65-4+ AF40, AF52, AF65 + BPR65-435 1.38"6 0.24"100.39"273.4 10.76"10ø 4.6 0.18ø 8.6 0.34M4 8-32 UNCø 4.2 0.17ø 6.4 0.25M4 8-32 UNCM6 1/4-20 UNC0.39"4.6 0.18"45 1.77"50.2"50.2"268.4 10.57"40 1.57"111 4.37"7 0.28"55 2.17"287.3 11.31”290 11.42”127.6 5.02"6 0.24"10 0.39"10 0.39"5.5 0.22"5.50.22"5.3 0.21"75 2.95"95.5 3.76"151.9 5.98”68.8 2.71”* For Ue>400V*1.5 0.06"*1.5 0.06"35 mm EN/IEC 607152X111 4.37"7 0.28"55 2.17"287.3 11.31”290 11.42”127.6 5.02"6 0.24"10 0.39"10 0.39"5.5 0.22"5.50.22"5.3 0.21"75 2.95"95.5 3.76"151.9 5.98”68.8 2.71”* For Ue>400V*1.5 0.06"*1.5 0.06"35 mm EN/IEC 607152XNote: for Ue > 400 V, contactor lateral distance to grounded component 1.5 mm 0.06" min.(1) Assembly on fixed DIN Rails for DOL starter with BPR65-4 rail hook*1.5 0.06"*1.5 0.06"6 0.24"55 2.17"5.5 0.22"95.5 3.76"10 0.39"10 0.39"5.5 0.22"287.3 11.31"6.5 0.26"288 11.34"122.1 4.81"45.7 1.80"195 7.68"105.5 4.15"* For Ue>400V(1)2x35mm EN/IEC60715BPR65-475 2.95"1SBC100088S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 12/1312
—Reversing starters protected by MS116 manual motor startersWith AF contactors - open type version in kit form186.8 7.35"60.24"50.20"50.20"50.20"50.20"Ø 4.5 0.18"100.39"351.38"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"90 3.54"35 mm EN/IEC 60715189.5 7.46"752.95"100.39"3,80.15"45 1.77"80.1 3.15"97 3.82"70 2.76"5.50.22"MS116-0.16 ... MS116-16 + BEA16-4, BER16-4, VEM4+ AF09, AF12, AF16 MS116-0.16 ... MS116-16 + BEA26-4, BER38-4, VEM4, CA4-10+ AF26, AF30, AF38 35 mm EN/IEC 60715198 7.80"752.95"45 1.77"80.1 3.15"70 2.76"5.50.22"100.39"5.5 0.22"90 3.54"114 4.49"198 7.80"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"35 mm EN/IEC 60715198 7.80"752.95"45 1.77"80.1 3.15"70 2.76"5.50.22"100.39"5.5 0.22"90 3.54"114 4.49"198 7.80"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"Note: contactor lateral distance to grounded component 2 mm 0.08" min.Coordination tables for MS166 available is our SOC tool :https://applications.it.abb.com/SOC/SelectivityMain dimensions mm, inches1SBC101924S020112/14ABB MOTOR PROTECTION AND CONTROL12
—Reversing starters protected by MS132 manual motor startersWith AF contactors - open type version in kit form186.8 7.35"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"90 3.54"35 mm EN/IEC 60715193.5 7.62"752.95"97 3.82"81.1 3.19"72.2 2.84"5.50.22"100.39"3.80.15"45 1.77"MS132-12 ... MS132-25 + BEA16-4, BER16-4, VEM4+ AF09, AF12, AF16 MS132-0.16 ... MS132-10 + BEA26-4, BER38-4, VEM4, CA4-10+ AF26, AF30, AF38 186.8 7.35"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"35 mm EN/IEC 60715752.95"81.3 3.20"72.4 2.85"5,5 0.22"45 1.77"10 0.39"5.5 0.22"114 4.49"198 7.80"90 3.54"186.8 7.35"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"90 3.54"35 mm EN/IEC 60715189.5 7.46"752.95"97 3.82"81.3 3.20"72.4 2.85"5.50.22"100.39"3.80.15"45 1.77"186.8 7.35"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"114 4.49"81.1 3.19"72.2 2.84"5.50.22"100.39"45 1.77"5.5 0.22"35 mm EN/IEC 6071590 3.54"201.5 7.93"752.95"186.8 7.35"60.24"50.20"50.20"50.20"50.20"702.76"Ø 4.5 0.18"100.39"803.15"26.251.03"Ø 4.2 0.17"M4 8-32UNCM4 8-32UNC17.50.69"50.20"114 4.49"81.1 3.19"72.2 2.84"5.50.22"100.39"45 1.77"5.5 0.22"35 mm EN/IEC 6071590 3.54"201.5 7.93"752.95"MS132-0.16 ... MS132-10 + BEA16-4, BER16-4, VEM4+ AF09, AF12, AF16 MS132-12 ... MS132-32 + BEA38-4, BER38-4, VEM4, CA4-10+ AF26, AF30, AF38 Main dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.1SBC101925S0201 ABB MOTOR PROTECTION AND CONTROL 12/1512
—Reversing starters protected by MS165 manual motor startersWith AF contactors - open type version in kit formMain dimensions mm, inchesMS165 + BEA65-4, BER65-4, VM96-4+ AF40, AF52, AF65 MS165 + BEA65-4, + AF40, AF52, AF65 + 2x BPR65-4273.4 10.76"40 1.57"100 3.94"110 4.33"268.4 10.57"4.6 0.18"5 0.2"6 0.24"35 1.38"100.39"100.39"ø 4.6 0.18ø 8.6 0.34M4 8-32 UNCø 4.2 0.17ø 6.4 0.25M4 8-32 UNCM6 1/4-20 UNC4.6 0.18"100 3.94"50.2"50.2"111 4.37"7 0.28"110 4.33"293.5 11.56"296 11.65"127.6 5.02"10 0.39"5.5 0.22"5.5 0.22"5.3 0.21"75 2.95"68.8 2.71"95.5 3.76"10 0.39"144 5.67"35 mm EN/IEC 607152X* For Ue>400V1.5 0.06"*1.5 0.06"*111 4.37"7 0.28"110 4.33"293.5 11.56"296 11.65"127.6 5.02"10 0.39"5.5 0.22"5.50.22"5.3 0.21"75 2.95"68.8 2.71"95.5 3.76"10 0.39"144 5.67"35 mmEN/IEC 607152X* For Ue>400V1.5 0.06"*1.5 0.06"*Note: for Ue > 400 V, contactor lateral distance to grounded component 1.5 mm 0.06" min.(1): Assembly on fixed DIN Rails for reverser starter with BPR65-4 rail hook* For Ue>400V2x35mm EN/IEC60715(1)BPR65-475 2.95"293.5 11.56"110 4.33"5.5 0.22"95.5 3.76"5.5 0.22"10 0.39"10 0.39"122.1 4.81"45.7 1.80"195 7.68"105.5 4.15"*1.5 0.06"*1.5 0.06"1SBC100091S0201 - Rev. A12/16ABB MOTOR PROTECTION AND CONTROL12
ABB MOTOR PROTECTION AND CONTROL 12/1712—Notes
—DOL starters protected by moulded-case circuit-breakers and overload relaysWith AF contactors - open type version in kit formApplicationFull voltage direct-on-line (DOL) starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.I/InC/Cn6543210710 306010080CII = currentC = torqueIn = nominal currentCn = nominal torqueCoordination typesThe contactor and the moulded-case circuit-breaker control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1/EN 60947-4-1) defining the anticipated level of service continuity as follow:Ty p e 1: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will not be able to then operate without being repaired or having parts replaced.Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will be able to operate afterwards. The risk of contacts light welding is acceptable.Main Technical DataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.400 V - 50/60 HzRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VSwitching frequency≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting timeAmbient air temperatureClose to the device< 55 °CDegree of protectionIP20Mounting positionsPos. 1Pos. 3Pos. 2Pos. 4+30°-30°Pos. 1 ± 30°Pos. 5Pos. 1Direct-on-lineMCCB + AFDirect-on-lineMCCB + AF + OLXT2S 160 + BEA140/XT2 + AF140-30-11 + EF1461SFC101190V0001XT2S 160 + BEA140/XT2 + AF140-30-111SFC101191V00011SBC101973S020112/18ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by moulded-case circuit-breakers and overload relaysWith AF contactors - open type version in kit formYou can easily assemble a direct-on-line starter by using the BEA connec-tion bars. It is used to electrically connect MCCB moulded-case circuit-breaker and AF116 ... AF370 contac-tor, AC or DC operated.Select now easily and quickly your starter in the following pages for coordination type 1 or 2 at 400 V, 50/60 Hz, Iq = 50 kA up to 200 kW.MCCB Moulded-case circuit-breaker including motor protection For the full coordination tables, please visit our SOC tool :https://applications.it.abb.com/SOC/SelectivityMCCB Moulded-case circuit-breaker (magnetic only)TF Thermal overload relayEFElectronic overload relayBEA Connection barAF116 ... AF370 ContactorBEA Connection barAF116 ... AF370 Contactor1SBC101973S0201 ABB MOTOR PROTECTION AND CONTROL 12/1912
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 HzMCCBContactorsConnection bars+IECMagnetic triping currentsettingMax. allowedthermal settingBaseTrip unitControl voltageUc min. ... Uc max.TypeOrder codeTy peOrder codeAC-3, 400 VTy peOrder codeTy peOrder codeRated powerRated currentkWAAV 50/60 HzV DC55971440116XT2S 160 1SDA068164R1+Ekip M-LIU In1601SDA067355R124...6020...60AF116-30-11-111SFL427001R1111BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920140XT2S 160 1SDA068164R1+Ekip M-LIU In1601SDA067355R124...6020...60AF140-30-11-111SFL447001R1111100...250100...250AF140-30-11-131SFL447001R1311901602400190T4S 250 PR222MP In2001SDA054527R1Included-24...6020...60AF190-30-11-111SFL487002R1111BEA205/T41SFN084806R1001100...250100...250AF190-30-11-131SFL487002R13111101952880205T5S 400 PR222MP In3201SDA054553R1Included-24...6020...60AF205-30-11-111SFL527002R1111100...250100...250AF205-30-11-131SFL527002R13111322303600265T5S 400 PR222MP In4001SDA054554R1Included-24...6020...60AF265-30-11-111SFL547002R1111BEA370/T51SFN085406R1000100...250100...250AF265-30-11-131SFL547002R13111602804400305T5S 400 PR222MP In4001SDA054554R1Included-24...6020...60AF305-30-11-111SFL587002R1111100...250100...250AF305-30-11-131SFL587002R1311—DOL starters protected by MCCB including motor protectionCoordination type 1 or 212/20ABB MOTOR PROTECTION AND CONTROL12
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 HzMCCBContactorsConnection bars+IECMagnetic triping currentsettingMax. allowedthermal settingBaseTrip unitControl voltage Uc min. ... Uc max.Ty peOrder codeTy peOrder codeAC-3, 400 VTy peOrder codeTy peOrder codeRated powerRated currentkWAAV 50/60 HzV DC55971440116XT2S 160 1SDA068164R1+Ekip M-LIU In1601SDA067355R124...60 20...60AF116-30-11-111SFL427001R1111BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920140XT2S 160 1SDA068164R1+Ekip M-LIU In1601SDA067355R124...60 20...60AF140-30-11-111SFL447001R1111100...250100...250AF140-30-11-131SFL447001R1311901602400190T4S 250 PR222MP In2001SDA054527R1Included-24...60 20...60AF190-30-11-111SFL487002R1111BEA205/T41SFN084806R1001100...250100...250AF190-30-11-131SFL487002R13111101952880205T5S 400 PR222MP In3201SDA054553R1Included-24...60 20...60AF205-30-11-111SFL527002R1111100...250100...250AF205-30-11-131SFL527002R13111322303600265T5S 400 PR222MP In4001SDA054554R1Included-24...60 20...60AF265-30-11-111SFL547002R1111BEA370/T51SFN085406R1000100...250100...250AF265-30-11-131SFL547002R13111602804400305T5S 400 PR222MP In4001SDA054554R1Included-24...60 20...60AF305-30-11-111SFL587002R1111100...250100...250AF305-30-11-131SFL587002R13111SBC101975S0201 ABB MOTOR PROTECTION AND CONTROL 12/2112
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 HzMCCBContactorsOverload relaysConnection barsThermal overload relaysIECMagnetic triping currentTy peOrder codeControl voltage Uc min. ... Uc max.TypeOrder codeSetting rangesMax. allowedsettingcurrentTy peOrder codeTy peOrder codeAC-3, 400 VRated powerRated currentkWAAV 50/60 HzV DCAA55971600XT2S 160 MA 1601SDA076530R124...60 20...60AF116-30-11-111SFL427001R111180...110110TF140DU-1101SAZ431201R1002BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920XT2S 160 MA 160 1SDA076530R124...60 20...60AF140-30-11-111SFL447001R1111110...142140TF140DU-1421SAZ431201R1004100...250100...250AF140-30-11-131SFL447001R1311901602250XT4S 250 Ekip I In2501SDA068480R124...60 20...60AF190-30-11-111SFL487002R1111130...175175TA200DU-1751SAZ421201R1005BEA205/XT41SFN084806R1000100...250100...250AF190-30-11-131SFL487002R13111101952720T4S 320 PR221-I In3201SDA054126R124...60 20...60AF205-30-11-111SFL527002R1111155...200200TA200DU-2001SAZ421201R1006BEA205/T41SFN084806R1001100...250100...250AF205-30-11-131SFL527002R1311Electronic overload relays55971600XT2S 160 MA 1601SDA076530R124...60 20...60AF116-30-11-111SFL427001R111154...150116EF146-1501SAX351001R1101BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920XT2S 160 MA 160 1SDA076530R124...60 20...60AF140-30-11-111SFL447001R111154...150140EF146-1501SAX351001R1101100...250100...250AF140-30-11-131SFL447001R1311901602250XT4S 250 Ekip I In2501SDA068480R124...60 20...60AF190-30-11-111SFL487002R111163...210190EF205-2101SAX531001R1101BEA205/XT41SFN084806R1000100...250100...250AF190-30-11-131SFL487002R13111101952720T4S 320 PR221-I In3201SDA054126R124...60 20...60AF205-30-11-111SFL527002R111163...210205EF205-2101SAX531001R1101BEA205/T41SFN084806R1001100...250100...250AF205-30-11-131SFL527002R13111322303200T5S 400 PR221-I In4001SDA054335R124...60 20...60AF265-30-11-111SFL547002R1111115...380265EF370-3801SAX611001R1101BEA370/T51SFN085406R1000100...250100...250AF265-30-11-131SFL547002R13111602804000T5S 400 PR221-I In4001SDA054335R124...60 20...60AF305-30-11-111SFL587002R1111115...380305EF370-3801SAX611001R1101100...250100...250AF305-30-11-131SFL587002R13112003505040T5S 630 PR221-I In6301SDA054405R124...60 20...60AF370-30-11-111SFL607002R1111115...380350EF370-3801SAX611001R1101100...250100...250AF370-30-11-131SFL607002R1311—DOL starters protected by MCCB (magnetic only) and overload relaysCoordination type 1 or 212/22ABB MOTOR PROTECTION AND CONTROL12
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 HzMCCBContactorsOverload relaysConnection barsThermal overload relaysIECMagnetic triping currentTy peOrder codeControl voltage Uc min. ... Uc max.Ty peOrder codeSetting rangesMax. allowedsettingcurrentTy peOrder codeTy peOrder codeAC-3, 400 VRated powerRated currentkWAAV 50/60 HzV DCAA55971600XT2S 160 MA 1601SDA076530R124...60 20...60AF116-30-11-111SFL427001R111180...110110TF140DU-1101SAZ431201R1002BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920XT2S 160 MA 160 1SDA076530R124...60 20...60AF140-30-11-111SFL447001R1111110...142140TF140DU-1421SAZ431201R1004100...250100...250AF140-30-11-131SFL447001R1311901602250XT4S 250 Ekip I In2501SDA068480R124...60 20...60AF190-30-11-111SFL487002R1111130...175175TA200DU-1751SAZ421201R1005BEA205/XT41SFN084806R1000100...250100...250AF190-30-11-131SFL487002R13111101952720T4S 320 PR221-I In3201SDA054126R124...60 20...60AF205-30-11-111SFL527002R1111155...200200TA200DU-2001SAZ421201R1006BEA205/T41SFN084806R1001100...250100...250AF205-30-11-131SFL527002R1311Electronic overload relays55971600XT2S 160 MA 1601SDA076530R124...60 20...60AF116-30-11-111SFL427001R111154...150116EF146-1501SAX351001R1101BEA140/XT21SFN084206R1000100...250100...250AF116-30-11-131SFL427001R1311751321920XT2S 160 MA 160 1SDA076530R124...60 20...60AF140-30-11-111SFL447001R111154...150140EF146-1501SAX351001R1101100...250100...250AF140-30-11-131SFL447001R1311901602250XT4S 250 Ekip I In2501SDA068480R124...60 20...60AF190-30-11-111SFL487002R111163...210190EF205-2101SAX531001R1101BEA205/XT41SFN084806R1000100...250100...250AF190-30-11-131SFL487002R13111101952720T4S 320 PR221-I In3201SDA054126R124...60 20...60AF205-30-11-111SFL527002R111163...210205EF205-2101SAX531001R1101BEA205/T41SFN084806R1001100...250100...250AF205-30-11-131SFL527002R13111322303200T5S 400 PR221-I In4001SDA054335R124...60 20...60AF265-30-11-111SFL547002R1111115...380265EF370-3801SAX611001R1101BEA370/T51SFN085406R1000100...250100...250AF265-30-11-131SFL547002R13111602804000T5S 400 PR221-I In4001SDA054335R124...60 20...60AF305-30-11-111SFL587002R1111115...380305EF370-3801SAX611001R1101100...250100...250AF305-30-11-131SFL587002R13112003505040T5S 630 PR221-I In6301SDA054405R124...60 20...60AF370-30-11-111SFL607002R1111115...380350EF370-3801SAX611001R1101100...250100...250AF370-30-11-131SFL607002R13111SBC101974S0201 ABB MOTOR PROTECTION AND CONTROL 12/2312
Protected by MCCB including motor protectionProtected by MCCB (magnetic only) and overload relaysDirect-on-line starters—DOL starters protected by moulded-case circuit-breakers and overload relaysWith AF contactors - Open type version in kit formA1A21/L1T1/L1K5 1QMT1/L3T1/L23/L25/L31/L13/L25/L313142/T14/T26/T31>1 >ᶯ0Y011 >>>m > 3E kip M - L1UE kip M - 1E kip M - LR1UUVWKM1A1A2KM11/L11>1>1>Q 1M3/L25/L32/T14/T26/T31/L13/L25/L313142/T14/T26/T3UVW95979698AMRESETSTOPTESTA1A21/L1T1/L1K5 1QMT1/L3T1/L23/L25/L31/L13/L25/L313142/T14/T26/T31>1 >ᶯ0Y011 >>>m > 3E kip M - L1UE kip M - 1E kipM - LR1UUVWKM1A1A2KM11/L11>1>1>Q 1M3/L25/L32/T14/T26/T31/L13/L25/L313142/T14/T26/T3UVW95979698AMRESETSTOPTEST1SBC101976S020112/24ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MCCB, including motor protectionWith AF contactors - Open type version in kit formMain dimensions mm, inchesXT2S 160 + Ekip M-LIU In160+ BE A 140/X T2+ AF116, AF140, AF146T4 S+ B E A 2 0 5/ T4+ AF190, AF205126 4.96"90 3.54"289 11.38"112 4.41"43.2 1.70"100 3.94"30 1.18"M4 8-32 UNC8 x105 4.13"152 5.98"410 16.14"39.51.56"35 1.39"M5 10-24 UNC12 x176 6.93"165 6.50"1SFC101187C0201 ABB MOTOR PROTECTION AND CONTROL 12/2512
—DOL starters protected by MCCB, including motor protectionWith AF contactors - Open type version in kit formMain dimensions mm, inchesT5S+ BEA370/T5+ AF265, AF305, AF370140 5.51"180 7.09"441 17.36"43.75 1.72"46.5 1.83"M5 10-24 UNC8 x187 7.36"45 1.77"176 6.93"1SFC101188C020112/26 ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MCCB (magnetic only) and thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesXT2S+ BE A 140/X T2+ AF116, AF140, AF146+ TF140 thermal overload relay112 4.41"43.2 1.70"45 1.77"100 3.94"82.3 3.24"30 1.18"37 1.46"50 1.97"M4 8-32 UNCM5 10-24 UNC8 x4 x126 4.96"90 3.54"398 15.67"1SFC101189C0201 ABB MOTOR PROTECTION AND CONTROL 12/2712
—DOL starters protected by MCCB (magnetic only) and thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesX T4 S+ B E A 2 0 5/ X T4+ AF190, AF205+ TA200DU thermal overload relay105 4.13"488 19.21"152 5.98"82 3.23"411.61"35 1.39"37 1.46"50 1.97"M4 8-32 UNC4 xM5 10-24 UNC8 x139 5.47"165 6.50"25.51.0"1SFC101190C020112/28ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MCCB (magnetic only) and thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesT4 S+ B E A 2 0 5/ T4+ AF190, AF205+ TA200DU thermal overload relay105 4.13"527 20.75"152 5.98"82 3.23"39.51.56"35 1.39"37 1.46"50 1.97"M5 10-24 UNC12 x176 6.93"165 6.50"25.51.0"1SFC101191C0201 ABB MOTOR PROTECTION AND CONTROL 12/2912
—DOL starters protected by MCCB (magnetic only) and electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesXT2S+ BE A 140/X T2+ AF116, AF140, AF146+ EF146 electronic overload relay126 4.96"90 3.54"408 16.06"112 4.41"43.8 1.72"94.7 3.73"30 1.18"37 1.46"M4 8-32 UNCM5 10-24 UNC10 x2 x43.2 1.70"100 3.94"21.50.85"1SFC101192C020112/30ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MCCB (magnetic only) and electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesX T4 S+ B E A 2 0 5/ X T4+ AF190, AF205+ EF205 electronic overload relay105 4.13"517.5 20.37"152 5.98"20.50.81"112 4.42"35 1.39"M5 10-24 UNC8 x165 6.50"411.61"139 5.47"M4 8-32 UNC4 x1SFC101193C0201 ABB MOTOR PROTECTION AND CONTROL 12/3112
—DOL starters protected by MCCB (magnetic only) and electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesT4 S+ B E A 2 0 5/ T4+ AF190, AF205+ EF205 electronic overload relay105 4.13"556.5 21.91"152 5.98"20.50.81"112 4.42"35 1.39"M5 10-24 UNC12 x165 6.50"39.5 1.56"176 6.93"1SFC101194C020112/32ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by MCCB (magnetic only) and electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesT5S+ BEA370/T5+ AF265, AF305, AF370+ EF370 electronic overload relay600.5 23.64"140 5.51"180 7.09"112 4.41"29 1.14"35 1.38"43.75 1.72"46.5 1.83"M5 10-24 UNC12 x187 7.36"45 1.77"176 6.93"1SFC101195C0201 ABB MOTOR PROTECTION AND CONTROL 12/3312
—DOL and reversing starters protected by overload relaysWith AF contactors - Open type version in kit formApplicationFull voltage direct-on-line and reversing starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.I/InC/Cn6543210710306010080CII = currentC = torqueIn = nominal currentCn = nominal torqueCoordination TypesThe contactor, the short-circuit protection device and the thermal overload relay control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:Ty p e 1: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will not be able to then operate without being repaired or having parts replaced.Ty p e 2 : In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will be able to operate afterwards. The risk of contacts light welding is acceptable.Main Technical DataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VAmbient air temperatureClose to the device≤ 60 °C (TF42: 38 A above ≤ 50 °C)Degree of protectionIP20Switching frequencyRefer to "Switching frequency diagrams" pageMounting positionsPos. 1Pos. 1Direct-on-lineReversingAF09-30-10 + TF421SBC100058V0014AF140-30-11 + TF140DU1SFC101153V0001AF09-30-10 + BER16-4 + VEM4 + TF421SBC100059V0014AF140-30-11 + BER140-4 + VM19 + TF140DU1SFC101152V00011SBC101920S020112/34 ABB MOTOR PROTECTION AND CONTROL12
Direct-On-Line startersReversing starters for AF09 ... AF38Reversing starters for AF116 ... AF370—DOL and reversing starters protected by overload relaysWith AF contactors - Open type version in kit formYou can easily assemble a direct-on-line starter by connecting AF contactor and TF thermal overload relay or EF electronic overload relay.You can also easily assemble reversing starter thanks to our complete range of accessories:• For AF09 ... AF38, use VEM4 mechanical and electrical interlock set for reversing starter in 90 mm width.• It includes: -VM4 mechanical interlock unit including 2 fixing clips -VE4 electrical interlock block with A2-A2 connection.• For AF40 ... AF370, use VM mechanical interlock unit and additional auxiliary contact blocks for electrical interlocking.• BER..-4 connection set: it assures a safe and simple reversing connection between both contactor main terminals.Select now easily and quickly your starter in the following pages at 400 V, up to 200 kW.AF09 ... AF96 ContactorAF09 ... AF38 ContactorsTF Thermal overload relayEFElectronic overload relayAF contactorwith built-in cable clampsAF contactorwith built-in cable clampsVM Mechanical interlock unitBER..-4 Connection setBER..-4 Connection setT F/ TA Thermal overload relay EFElectronic overload relayVE4 Electrical interlock blockBER..-4 Connection setAF09 ... AF65 ContactorA2A2Fixing clipVM4 Mechanical interlock unitFor the full coordination tables, please visit our SOC tool :https://applications.it.abb.com/SOC/Selectivity1SBC101920S0201 ABB MOTOR PROTECTION AND CONTROL 12/3512
ContactorsThermal overload relaysAccessoriesIECControl voltage Uc min. ... Uc max.(1)Ty peOrder codeSetting rangesTy peOrder codeAC-3, 400 VRated powerRated currentkWAV 50/60 Hz V DC (2)A48.524...60 20...60AF09Z-30-10-111SBL136001R11107.60...10.0TF42-101SAZ711201R1043100...250 100...250AF09-30-10-131SBL137001R13105.511.524...60 20...60AF12Z-30-10-111SBL156001R111010.0...13.0TF42-131SAZ711201R1045100...250 100...250AF12-30-10-13 1SBL157001R13107.515.524...60 20...60AF16Z-30-10-111SBL176001R111013.0...16.0TF42-161SAZ711201R1047100...250 100...250AF16-30-10-131SBL177001R1310112224...60 20...60AF26Z-30-00-111SBL236001R110020.0...24.0TF42-241SAZ711201R1051100...250 100...250AF26-30-00-13 1SBL237001R1300152924...60 20...60AF30Z-30-00-111SBL276001R110029.0...35.0TF42-351SAZ711201R1053100...250 100...250AF30-30-00-131SBL277001R130018.53524...60 20...60AF38Z-30-00-111SBL296001R110035.0...38.0/40.0TF42-381SAZ711201R1055100...250 100...250AF38-30-00-13 1SBL297001R130018.53524...60 20...60AF40-30-00-111SBL347001R110030.0...40.0TF65-401SAZ811201R1003100...250 100...250AF40-30-00-131SBL347001R1300224124...6020...60AF52-30-00-111SBL367001R110036.00...47.0TF65-471SAZ811201R1004100-250100-250AF52-30-00-13 1SBL367001R1300305524...6020...60AF65-30-00-111SBL387001R110050.0...60.0TF65-601SAZ811201R1006100-250100-250AF65-30-00-13 1SBL387001R1300376624...6020...60AF80-30-00-111SBL397001R110057.0...68.0TF96-681SAZ911201R1003100-250100-250AF80-30-00-131SBL397001R1300458024...6020...60AF96-30-00-111SBL407001R110075.0..87.0TF96-871SAZ911201R1005100-250100-250AF96-30-00-13 1SBL407001R1300559724...6020...60AF116-30-11-11 1SFL427001R111180...110TF140DU-1101SAZ431201R1002100-250100-250AF116-30-11-131SFL427001R13117513224...6020...60AF140-30-11-111SFL447001R1111100...135TF140DU-1351SAZ431201R1003100-250100-250AF140-30-11-131SFL447001R13119016024...6020...60AF190-30-11-111SFL487002R1111130...175TA200DU-1751SAZ411201R1005100-250100-250AF190-30-11-13 1SFL487002R131111019524...6020...60AF205-30-11-111SFL527002R1111150...200TA200DU-200 1SAZ411201R1006100-250100-250AF205-30-11-131SFL527002R1311(1) For other control voltages, see "Voltage code table".Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".(2) AF ... -11 not suitable for direct control by PLC-output.—Direct-on-line starters protected by thermal overload relaysWith AF contactors - Open type version in kit form1SBC101921S020112/36ABB MOTOR PROTECTION AND CONTROL12
ContactorsThermal overload relaysAccessories + IECControl voltage Uc min. ... Uc max.(1)Ty peOrder codeSetting rangesTy peOrder codeTy peOrder codeAC-3, 400 VRated powerRated currentkWAV 50/60 HzV DCA48.524...60 20...60AF09Z-30-10-111SBL136001R11107.60...10.0TF42-101SAZ711201R1043+BER16-4VEM41SBN081311R10001SBN030111R1000100...250100...250AF09-30-10-131SBL137001R13105.511.524...60 20...60AF12Z-30-10-111SBL156001R111010.0...13.0TF42-131SAZ711201R1045100...250100...250AF12-30-10-131SBL157001R13107.515.524...60 20...60AF16Z-30-10-111SBL176001R111013.0...16.0TF42-161SAZ711201R1047100...250100...250AF16-30-10-131SBL177001R1310112224...60 20...60AF26Z-30-00-111SBL236001R110020.0...24.0TF42-241SAZ711201R1051++ 2xBER38-4 VEM4 CA4-101SBN082311R10001SBN030111R10001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300152924...60 20...60AF30Z-30-00-111SBL276001R110029.0...35.0TF42-351SAZ711201R1053100...250100...250AF30-30-00-131SBL277001R130018.53524...60 20...60AF38Z-30-00-111SBL296001R110035.0...38.0/40.0TF42-381SAZ711201R1055100...250100...250AF38-30-00-131SBL297001R130018.53524...60 20...60AF40-30-00-111SBL347001R110030.0...40.0TF65-401SAZ811201R1003++ 2x+ 2xBER65-4VM96-4CA4-10CA4-011SBN083411R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300224124...60 20...60AF52-30-00-111SBL367001R110036.00...47.0TF65-471SAZ811201R1004100...250100...250AF52-30-00-131SBL367001R1300305524...60 20...60AF65-30-00-111SBL387001R110050.0...60.0TF65-601SAZ811201R1006100...250100...250AF65-30-00-131SBL387001R1300376624...60 20...60AF80-30-00-111SBL397001R110057.0...68.0TF96-681SAZ911201R1003++ 2x+ 2xBER96-4VM96-4CA4-10CA4-011SBN083911R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300458024...60 20...60AF96-30-00-111SBL407001R110075.0..87.0TF96-871SAZ911201R1005100...250100...250AF96-30-00-131SBL407001R1300559724...60 20...60AF116-30-11-111SFL427001R111180...110TF140DU-1101SAZ431201R1002+BER140-4VM19 1SFN084111R10001SFN030300R1000100...250100...250AF116-30-11-131SFL427001R13117513224...60 20...60AF140-30-11-111SFL447001R1111100...135TF140DU-1351SAZ431201R1003100...250100...250AF140-30-11-131SFL447001R13119016024...60 20...60AF190-30-11-111SFL487002R1111130...175TA200DU-1751SAZ411201R1005+BER205-4VM19 1SFN084811R10001SFN030300R1000100...250100...250AF190-30-11-131SFL487002R131111019524...60 20...60AF205-30-11-111SFL527002R1111150...200TA200DU-2001SAZ411201R1006100...250100...250AF205-30-11-131SFL527002R1311(1) For other control voltages, see "Voltage code table".Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".(2) AF ... -11 not suitable for direct control by PLC-output.BER..-4VEM4CA4-10—Reversing starters protected by thermal overload relaysWith AF contactors - Open type version in kit form1SBC101922S0201 ABB MOTOR PROTECTION AND CONTROL 12/3712
12/38 ABB MOTOR PROTECTION AND CONTROLContactorsElectronic overload relaysAccessoriesIECControl voltage Uc min. ... Uc max.(1)Ty peOrder codeSetting rangesTy peOrder codeAC-3, 400 VRated powerRated currentkWAV 50/60 HzV DCA48.524...60 20...60AF09Z-30-10-111SBL136001R11105.70...18.9EF19-18.91SAX111001R1105100...250100...250AF09-30-10-131SBL137001R13105.511.524...60 20...60AF12Z-30-10-111SBL156001R11105.70...18.9EF19-18.91SAX111001R1105100...250100...250AF12-30-10-131SBL157001R13107.515.524...60 20...60AF16Z-30-10-111SBL176001R11105.70...18.9EF19-18.91SAX111001R1105100...250100...250AF16-30-10-131SBL177001R1310112224...60 20...60AF26Z-30-00-111SBL236001R11009.00...30.0EF45-301SAX211001R1101100...250100...250AF26-30-00-131SBL237001R1300152924...60 20...60AF30Z-30-00-111SBL276001R11009.00...30.0EF45-301SAX211001R1101100...250100...250AF30-30-00-131SBL277001R130018.53524...60 20...60AF38Z-30-00-111SBL296001R110015.0...45.0EF45-451SAX211001R1102100...250100...250AF38-30-00-131SBL297001R130018.53524...60 20...60AF40-30-00-111SBL347001R110025.0...70.0EF65-701SAX331001R1101100...250100...250AF40-30-00-131SBL347001R1300224124...6020...60AF52-30-00-111SBL367001R110025.0...70.0EF65-701SAX331001R1101100-250100-250AF52-30-00-131SBL367001R1300305524...6020...60AF65-30-00-111SBL387001R110025.0...70.0EF65-701SAX331001R1101100-250100-250AF65-30-00-131SBL387001R1300376624...6020...60AF80-30-00-111SBL397001R110036...100EF96-1001SAX341001R1101100-250100-250AF80-30-00-131SBL397001R1300458024...6020...60AF96-30-00-111SBL407001R110036...100EF96-1001SAX341001R1101100-250100-250AF96-30-00-131SBL407001R1300559724...6020...60AF116-30-11-111SFL427001R111154...150EF146-1501SAX351001R1101100-250100-250AF116-30-11-131SFL427001R13117513224...6020...60AF140-30-11-111SFL447001R111154...150EF146-1501SAX351001R1101100-250100-250AF140-30-11-131SFL447001R13119016024...6020...60AF190-30-11-111SFL487002R111163...110EF205-1101SAX531001R1101100-250100-250AF190-30-11-131SFL487002R131111019524...6020...60AF205-30-11-111SFL527002R111163...110EF205-1101SAX531001R1101100-250100-250AF205-30-11-131SFL527002R131113223024...6020...60AF265-30-11-111SFL547002R1111115...380EF370-3801SAX611001R1101100-250100-250AF265-30-11-131SFL547002R131116028024...6020...60AF305-30-11-111SFL587002R1111115...380EF370-3801SAX611001R1101100-250100-250AF305-30-11-131SFL587002R131120035024...6020...60AF370-30-11-111SFL607002R1111115...380EF370-3801SAX611001R1101100-250100-250AF370-30-11-131SFL607002R1311(1) For other control voltages, see "Voltage code table".(2) AF ... -11 not suitable for direct control by PLC-output.—Direct-on-line starters protected by electronic overload relaysWith AF contactors - Open type version in kit form1SBC101948S020112
ContactorsElectronic overload relaysAccessories + IECControl voltage Uc min. ... Uc max.(1)Ty peOrder codeSetting rangesTy peOrder codeTy peOrder codeAC-3, 400 VRated powerRated currentkWAV 50/60 HzV DCA48.524...60 20...60AF09Z-30-10-111SBL136001R11105.70...18.9EF19-18.91SAX111001R1105+BER16-4VEM41SBN081311R10001SBN030111R1000100...250100...250AF09-30-10-131SBL137001R13105.511.524...60 20...60AF12Z-30-10-111SBL156001R11105.70...18.9EF19-18.91SAX111001R1105100...250100...250AF12-30-10-131SBL157001R13107.515.524...60 20...60AF16Z-30-10-111SBL176001R11105.70...18.9EF19-18.91SAX111001R1105100...250100...250AF16-30-10-131SBL177001R1310112224...60 20...60AF26Z-30-00-111SBL236001R11009.00...30.0EF45-301SAX211001R1101++ 2xBER38-4 VEM4 CA4-101SBN082311R10001SBN030111R10001SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300152924...60 20...60AF30Z-30-00-111SBL276001R11009.00...30.0EF45-301SAX211001R1101100...250100...250AF30-30-00-131SBL277001R130018.53524...60 20...60AF38Z-30-00-111SBL296001R110015.0...45.0EF45-451SAX211001R1102100...250100...250AF38-30-00-131SBL297001R130018.53524...60 20...60AF40-30-00-111SBL347001R110025.0...70.0EF65-701SAX331001R1101++ 2x+ 2xBER65-4VM96-4CA4-10CA4-011SBN083411R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300224124...60 20...60AF52-30-00-111SBL367001R110025.0...70.0EF65-701SAX331001R1101100...250100...250AF52-30-00-131SBL367001R1300305524...60 20...60AF65-30-00-111SBL387001R110025.0...70.0EF65-701SAX331001R1101100...250100...250AF65-30-00-131SBL387001R1300376624...60 20...60AF80-30-00-111SBL397001R110036...100EF96-1001SAX341001R1101++ 2x+ 2xBER96-4VM96-4CA4-10CA4-011SBN083911R10001SBN033405T10001SBN010110R10101SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300458024...60 20...60AF96-30-00-111SBL407001R110036...100EF96-1001SAX341001R1101100...250100...250AF96-30-00-131SBL407001R1300559724...60 20...60AF116-30-11-111SFL427001R111154...150EF146-1501SAX351001R1101+BER140-4VM19 1SFN084111R10001SFN030300R1000100...250100...250AF116-30-11-131SFL427001R13117513224...60 20...60AF140-30-11-111SFL447001R111154...150EF146-1501SAX351001R1101100...250100...250AF140-30-11-131SFL447001R13119016024...60 20...60AF190-30-11-111SFL487002R111163...110EF205-1101SAX531001R1101+BER205-4VM19 1SFN084811R10001SFN030300R1000100...250100...250AF190-30-11-131SFL487002R131111019524...60 20...60AF205-30-11-111SFL527002R111163...110EF205-1101SAX531001R1101100...250100...250AF205-30-11-131SFL527002R131113223024...60 20...60AF265-30-11-111SFL547002R1111115...380EF370-3801SAX611001R1101+BER370-4VM19 1SFN085411R10001SFN030300R1000100...250100...250AF265-30-11-131SFL547002R131116028024...60 20...60AF305-30-11-111SFL587002R1111115...380EF370-3801SAX611001R1101100...250100...250AF305-30-11-131SFL587002R131120035024...60 20...60AF370-30-11-111SFL607002R1111115...380EF370-3801SAX611001R1101100...250100...250AF370-30-11-131SFL607002R1311(1) For other control voltages, see "Voltage code table".(2) AF ... -11 not suitable for direct control by PLC-output.BER..-4VEM4CA4-10—Reversing starters protected by electronic overload relaysWith AF contactors - Open type version in kit form1SBC101949S0201 ABB MOTOR PROTECTION AND CONTROL 12/3912
—DOL and reversing starters protected by overload relaysWith AF contactors - Open type version in kit formSwitching frequency diagramsThermal overload relayElectronic overload relayDuty ratio (%)Duty ratio (%)Duty ratio (%)Duty ratio (%)Switching frequency (ops/h)Switching frequency (ops/h)Switching frequency (ops/h)Switching frequency (ops/h)ta: motor starting timeExample: Starting time of the motor: 1 second - Duty ratio: 40 % means a permitted switching frequency of max. 60 operating cycles per hour.Exemple for trip class 10E:Starting time of the motor: 1 second. Duty ratio: 60 % means a permitted switching frequency of max. 60 operating cycles per hour, for a motor breaking current not exceeding 6 x In.Intermittent periodic dutyIntermittent periodic dutyGeneralOverload relays cannot be operated at any arbitrary switching frequency in order to avoid tripping. Applications involving up to 15 operations per hour are acceptable. Higher switching frequencies are permitted if the duty ratio and the motor start-ing time are allowed for and if the motor's making current does not appreciably exceed 6 times the rated operating current. Please refer to the adjacent diagram for guideline values for the permitted switching frequency.ta: motor starting timeTrip class 10ETrip class 20ETrip class 30Eduty ratioswitching frequency(Op/h)(%)140120020406080100020406080100 t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 saduty ratio (Op/h)switching frequency Trip class 10E (%)0 20 40 60 80 100 120 140 160 0 20406080100t = 1 sat = 1.5 sat = 3 sat = 5 sat = 0.5 saduty ratio (Op/h)switching frequency Trip class 20E (%)0 10 20 30 40 50 60 70 80 0 20406080100t = 4 sat = 8 sat = 10 sat = 12 sat = 2 sat = 6 saduty ratio (Op/h)switching frequency Trip class 30E (%)0 5 10 15 20 25 30 35 45 0 2040608010040 50 t = 10 sat = 20 sat = 25 sat = 5 sat = 15 sa1SBC101954S02011 2/4 0ABB MOTOR PROTECTION AND CONTROL12
.3KM1.4.3KM2.4III 01KM1:5/L3 UsIII KM1KM2O.3KM1.4.3KM2.4A201A2(2)(2)(1)(3)KM2A1A21/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T3TESTSTOPRESETMA989796956/T34/T22/T1FR101KM1KM2A201A2(2)(2)(1)(3)KM1:5/L3 UsFR19596AMRESETSTOPFR19596AMRESETSTOP UsN KM1:3/L2 UsN KM1:3/L2UWM~VA2KM1A122KM221A2A1KM222KM121A2KM1A122KM221A2A1KM222KM121KM113KM114A1A2 UsN KM1:3/L2IFR19596IOKM1:5/L3 Us UsN KM1:3/L213KM114A2A1KM1FR195961314KM1A1A21/L13/L25/L32/T14/T26/T3FR12/T14/T26/T395969798AMRESETSTOPTEST~MWVU13141/L13/L25/L32/T14/T26/T3FR12/T14/T26/T3UVM~AMRESETSTOPAMRESETSTOPKM1:5/L3 Us—DOL and reversing starters protected by overload relaysWith AF contactors - Open type version in kit formWiring diagramsPower circuit1-phaseAC or DC local controlAC or DC remote controlDirect-on-line startersNote: coil Uc 12-20 V DC : A1+, A2-Reversing startersPower circuitAC or DC local controlAC or DC remote controlNote: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection (Except for coil Uc 12-20 V DC : use VM4 with CA4). - coil Uc 12-20 V DC : A1+, A2-With VMWith VMWith VEM4With VEM41SBC101926S0201 ABB MOTOR PROTECTION AND CONTROL 12/4112
70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"106.8 4.20"211 8.31"110.9 4.37"4 0.16"35 x 15 mm EN/IEC 60715—DOL starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.45 1.77"156.1 6.15"77 3.03"71 2.80"5.5 0.22"35 mm EN/IEC 60715100.39"5.5 0.22"6.20.24"72.7 2.86"76.8 3.02"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"158.9 6.26"86 3.39"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"158.9 6.26"86 3.39"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNCAF26, AF30, AF38 + TF42 thermal overload relayAF09, AF12, AF16+ TF42 thermal overload relayAF40, AF52, AF65+ TF65 thermal overload relay111 4.37"7 0.28"55 2.17"10 0.39"35 mm EN/IEC 607155.5 0.22"106.8 4.20"110.6 4.35"4 0.16"208.5 8.21"AF40, AF52, AF65+ TF65 thermal overload relay45 1.77"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC2 x2 xAF80, AF96+ TF96 thermal overload relayAF80, AF96+ TF96 thermal overload relayø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"1SBC101927S02011 2/4 2ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF116, AF140-30-11(B) + TF140 thermal overload relay126 4.96"90 3.54"259 10.20"17 0.67"3 0.12"6 0.24"8 0.31"100 3.94"45 1.77"82.3 3.24"30 1.18"37 1.46"50 1.97"M4 8-32 UNCM5 10-24 UNC4 x4 xAF116, AF140-30-11(B) + TF140 thermal overload relayAF190, AF205-30-11 + TA200DU thermal overload relay105 4.13"312.5 12.3"152 5.98"35.5 1.40"5 0.20"62 2.44"42.5 1.67"20 0.79"ø 11 0.43"126 4.96"4 0.16"11 0.43"21 0.83"82 3.23"25.51.0"35 1.39"37 1.46"50 1.97"M5 10-24 UNC8 x165 6.50"AF190, AF205+ TA200DU thermal overload relay1SFC101156C0201 ABB MOTOR PROTECTION AND CONTROL 12/4312
—Reversing starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.AF26, AF30, AF38+ BER38-4, VEM4, CA4-10 + TF42 thermal overload relay60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"100.39"166.5 6.56"102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 mm EN/IEC 607155.5 0.22"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"100.39"166.5 6.56"102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 mm EN/IEC 607155.5 0.22"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"90 3.54"170 6.69"119.5 4.70"AF09, AF12, AF16+ BER16-4, VEM4+ TF42 thermal overload relayAF09, AF12, AF16, AF26, AF30, AF381SBC101928S02011 2/4 4 ABB MOTOR PROTECTION AND CONTROL12
—Reversing starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF40, AF52, AF65+ BER65-4, VM96-4+ TF65 thermal overload relay AF80, AF96+ BER96-4, VM96-4+ TF96 thermal overload relayAF80, AF96+ BER96-4, VM96-4+ TF96 thermal overload relayAF40, AF52, AF65+ BER65-4, VM96-4+ TF65 thermal overload relay100.39"5.5 0.22"106.8 4.20"110.6 4.35"4 0.16"144 5.67"111 4.37"110 4.33"223 8.78"35 x 15 mm EN/IEC 6071535 x 7.5 mm EN/IEC 60715116 4.57"100.39"5.5 0.22"149 5.87"35 x 15 mm EN/IEC 60715106.8 4.20"110.9 4.37"4 0.16"140 5.51"226 8.90"100 3.94"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC130 5.12"ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC1SBC101929S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/4512
—Reversing starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF116, AF140, AF146 + BER140-4, VM19+ TF140 thermal overload relay180 7.09"126 4.96"272 10.71"60 2.36"8x30 1.18"M4 8-32 UNC100 3.94"30 1.18"45 1.77"82.3 3.24"37 1.46"50 1.97"M5 10-24 UNC4 x1SFC101158C02011 2/4 6ABB MOTOR PROTECTION AND CONTROL12
N1ABB MOTOR PROTECTION AND CONTROL 12/471 2/47ABB MOTOR PROTECTION AND CONTROL12
12
ABB MOTOR PROTECTION AND CONTROL 12/49 Starters protected by manual motor starters12/50 Overview12/52 Direct-on-line starters12/56 Reversing starters12/60 Dimensions Starters protected by thermal overload relays12/62 Direct-on-line and reversing starters12/66 Star-delta starters12/70 Dimensions Star-delta starters prtoected by overload relays12/82 Overview12/84 Selection tables12/88 Switching frequency diagrams12/91 Main dimensions —Motor starting solutionsOpen type version, in kit form with screw terminals12
1SBC101271S020112/50 ABB MOTOR PROTECTION AND CONTROLI > I > YΔL MS116Manual motor starterBEA16-3Connecting linkASASLContactorsASASLContactors—Motor starting solutionsOpen type version, in kit formStarters protected by manual motor startersStarters protected by thermal overload relaysReversing startersDirect-on-line startersDirect-on-line startersMS116Manual motor starterBEA16-3Connecting linkASASLContactorsBER16C-3 Connection setT16 Thermal overload relayAS ASL ContactorsReversing startersBER16C-3 Connection setT16 Thermal overload relayVM3 Mechanical interlock unitStar-delta startersT16 Thermal overload relayAS ASL ContactorsBEY16C-3 Connection setTimerCA3 1-pole auxiliary contact block12
1SBC101271S0201 ABB MOTOR PROTECTION AND CONTROL 12/51Switching of 3-phase cage motorsDirect-on-line startersReversing startersRated power - AC-3, 400 V4...7.5 kW4...7.5 kWContactorsAC operatedAS09 ... AS16AS09 ... AS16DC operatedASL09 ... ASL16ASL09 ... ASL16Thermal overload relaysT16T16Switching of 3-phase cage motorsDirect-on-line startersReversing startersRated power - AC-3, 400 V0.06...7.5 kW0.06...7.5 kWShort-circuit current Iq16 kA - 50 kA16 kA - 50 kACoordination typeType 1 & type 2Type 1 & type 2Manual motor startersMS116MS116ContactorsAC operatedAS09 ... AS16AS09 ... AS16DC operatedASL09 ... ASL16ASL09 ... ASL16Switching of 3-phase cage motorsStar-delta startersRated power - AC-3, 400 V7.5...11 kWContactorsAC operatedAS09 ... AS16DC operatedASL09 ... ASL16Thermal overload relaysT16—Starters protected by manual motor starters—Starters protected by thermal overload relays12
1SBC101272S020112/52 ABB MOTOR PROTECTION AND CONTROLApplicationFull voltage direct-on-line starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.I/InC/Cn6543210710306010080CICoordination typesThe contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will not be able to then operate without being repaired or having parts replaced.Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will be able to operate afterwards. The risk of contacts light welding is acceptable.Main technical dataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Ui according to IEC 60947-4-1690 VSwitching frequency≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting timeAmbient air temperature close to the device≤ 55 °CDegree of protectionIP20I = currentC = torqueIn = nominal currentCn = nominal torqueMounting positionsPos. 1Pos. 1 ± 30°Pos. 4Pos. 2Pos. 5+30°-30°Pos. 3Pos. Posos—Direct-on-line starters protected by manual motor startersWith AS, ASL contactors - open type version in kit form1SBC101030F0014MS116 + BEA16-3 + AS16-30-10I > 12
1SBC101272S0201 ABB MOTOR PROTECTION AND CONTROL 12/53Wiring diagramsI>I>I>Q1343344432/ T14/ T26/ T3M3V1U1W1KM1A1A213141/ L13/ L25/ L31/ L13/ L25/ L32/ T14/ T26/ T3I>I>I>Q1343344432/ T14/ T26/ T3MKM1A1A213141/ L13/ L25/ L31/ L13/ L25/ L32/ T14/ T26/ T333344344Q1OKM113KM114A1A2UsNKM1:3/L2KM1:5/L3UsIQ143IO3334KM1:5/L3UsQ144Q1UsNKM1:3/L213KM114A2A1KM1KM113KM114A1+A2-IO3334Q143Q144+-IO13KM114A2-A1+KM13334Q143Q144+-—Direct-on-line starters protected by manual motor startersWith AS, ASL contactors - open type version in kit formYou can easily assemble a direct-on-line starter by using the BEA16-3 connecting link 3-pole insulated. It is used to electrically and mechanically connect MS116 manual motor starter and AS or ASL contactors.Select now easily and quickly your starter in the following pages for coordination type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up to 7.5 kW. For complete coordination tables with MS116 or MS132, please contact your ABB local sales organization.AC local controlDC local controlPower circuit1-phaseAC remote controlDC remote controlI > MS116Manual motor starterBEA16-3Connecting linkASASLContactors12
1SBC101383S0201 - Rev. A12/54ABB MOTOR PROTECTION AND CONTROLMain accessoriesTy pe Order codeConnecting link for manual motor starterBEA16-31SBN081006T1000Coordination type 1 or type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzI > Manual motor startersContactorsIECTy peOrder codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc(1)Ty peOrder codeAllowed setting currentAC-3, 400 VRated operationalpowercurrentkWAAAV 50 Hz V 60 HzACoordination type 1 Coordination type 2Iq = 16 kAIq = 50 kA0.060.2MS116-0.251SAM250000R10020.16...0.252.442424AS09-30-10-201SBL101001R20100.25230230AS09-30-10-261SBL101001R26100.090.3MS116-0.41SAM250000R10030.25...0.403.92424AS09-30-10-201SBL101001R20100.4230230AS09-30-10-261SBL101001R26100.120.44MS116-0.631SAM250000R10040.40...0.636.142424AS09-30-10-201SBL101001R20100.63230230AS09-30-10-261SBL101001R26100.180.6MS116-1.01SAM250000R10050.63...1.0011.52424AS09-30-10-201SBL101001R20101230230AS09-30-10-261SBL101001R26100.250.85MS116-1.01SAM250000R10050.63...1.0011.52424AS09-30-10-201SBL101001R20101230230AS09-30-10-261SBL101001R26100.371.1MS116-1.61SAM250000R10061.00...1.6018.42424AS09-30-10-201SBL101001R20101.6230230AS09-30-10-261SBL101001R26100.551.5MS116-1.61SAM250000R10061.00...1.6018.42424AS09-30-10-201SBL101001R20101.6230230AS09-30-10-261SBL101001R26100.751.9MS116-2.51SAM250000R10071.60...2.5028.752424AS09-30-10-201SBL101001R20102.5230230AS09-30-10-261SBL101001R26101.12.7MS116-4.01SAM250000R10082.50...4.00502424AS09-30-10-201SBL101001R20104230230AS09-30-10-261SBL101001R26101.53.6MS116-4.01SAM250000R10082.50...4.00502424AS09-30-10-201SBL101001R20104230230AS09-30-10-261SBL101001R26102.24.9MS116-6.31SAM250000R10094.00...6.3078.752424AS09-30-10-201SBL101001R20106.3230230AS09-30-10-261SBL101001R261036.5MS116-101SAM250000R10106.30...10.01502424AS12-30-10-201SBL111001R201010230230AS12-30-10-261SBL111001R261048.5MS116-101SAM250000R10106.30...10.01502424AS12-30-10-201SBL111001R201010230230AS12-30-10-261SBL111001R26105.511.5MS116-121SAM250000R10128.00...12.01802424AS12-30-10-201SBL111001R201012230230AS12-30-10-261SBL111001R26107.515.5MS116-161SAM250000R101110.0...16.02402424AS16-30-10-201SBL121001R201015.5230230AS16-30-10-261SBL121001R2610Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.—DOL starters protected by MS116 manual motor startersWith AS contactors - open type version in kit form12
1SBC101383S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/55Coordination type 1 or type 2, AC-3, 16 or 50 kA, 400 V, 50/60 HzI > Manual motor startersContactorsIECTy peOrder codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc(1)Ty peOrder codeAllowed setting currentAC-3, 400 VRated operationalpowercurrentkWAAAV DCACoordination type 1 Coordination type 2Iq = 16 kAIq = 50 kA0.060.2MS116-0.251SAM250000R10020.16...0.252.4424ASL09-30-10-811SBL103001R81100.250.090.3MS116-0.41SAM250000R10030.25...0.403.924ASL09-30-10-811SBL103001R81100.40.120.44MS116-0.631SAM250000R10040.40...0.636.1424ASL09-30-10-811SBL103001R81100.630.180.6MS116-1.01SAM250000R10050.63...1.0011.524ASL09-30-10-811SBL103001R811010.250.85MS116-1.01SAM250000R10050.63...1.0011.524ASL09-30-10-811SBL103001R811010.371.1MS116-1.61SAM250000R10061.00...1.6018.424ASL09-30-10-811SBL103001R81101.60.551.5MS116-1.61SAM250000R10061.00...1.6018.424ASL09-30-10-811SBL103001R81101.60.751.9MS116-2.51SAM250000R10071.60...2.5028.7524ASL09-30-10-811SBL103001R81102.51.12.7MS116-4.01SAM250000R10082.50...4.005024ASL09-30-10-811SBL103001R811041.53.6MS116-4.01SAM250000R10082.50...4.005024ASL09-30-10-811SBL103001R811042.24.9MS116-6.31SAM250000R10094.00...6.3078.7524ASL09-30-10-811SBL103001R81106.336.5MS116-101SAM250000R10106.30...10.015024ASL12-30-10-811SBL113001R81101048.5MS116-101SAM250000R10106.30...10.015024ASL12-30-10-811SBL113001R8110105.511.5MS116-121SAM250000R10128.00...12.018024ASL12-30-10-811SBL113001R8110127.515.5MS116-161SAM250000R101110.0...16.024024ASL16-30-10-811SBL123001R811015.5Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.—DOL starters protected by MS116 manual motor startersWith ASL contactors - open type version in kit formMain accessoriesTy pe Order codeConnecting link for manual motor starterBEA16-31SBN081006T100012
1SBC101274S020112/56 ABB MOTOR PROTECTION AND CONTROL—Reversing starters protected by manual motor startersWith AS, ASL contactors - open type version in kit formMS116 + BEA16-3 + VM3 + BER16C-3 + AS16-30-01ApplicationFull voltage reversing starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.I/InC/Cn6543210710306010080CICoordination typesThe contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate without being repaired or having parts replaced.Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards. The risk of contacts light welding is acceptable.Main technical dataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Ui according to IEC 60947-4-1690 VSwitching frequency≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting timeAmbient air temperature close to the device≤ 55 °CDegree of protectionIP20Note: Minimum switchover delay of 50 ms must be introduced between respective opening and closing of AC operated reversing contactorsI = currentC = torqueIn = nominal currentCn = nominal torqueMounting positionsPos. 1Pos. 1 ± 30°Pos. 2Pos. 5+30°-30°Pos. PososPos. 4Pos. 3I > 1SBC101027F001412
1SBC101274S0201 ABB MOTOR PROTECTION AND CONTROL 12/57Wiring diagramsM3V1U1W113142221333443441314KM2A1A21/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T3I> I>I>2221Q12/T14/T26/T31/L13/L25/L33334Q14344Q1UsNKM2:3/L2KM2:5/L3UsIII KM1KM1KM222212221O13KM11413KM214A1A2A1A2 3334Q14344Q1III KM1KM1KM222212221O13KM11413KM214A1+A1+A2-KM2A2-+-OKM2:5/L3Us33344344Q1UsNKM2:3/L2Q1KM213KM11413KM214A1A2A1A2KM1III 21KM2KM22221KM122+-O3334Q14344Q113KM11413KM214A1+A2-A1+A2-KM1III 21KM22221KM122KM2—Reversing starters protected by manual motor startersWith AS, ASL contactors - open type version in kit formYou can easily assemble reversing starter thanks to our complete range of-accessories:• BEA16-3 connecting link 3-pole insulated: it is used to electrically and mechanically connect MS116 manual motor starter and AS or ASL contac-tors.• VM3 mechanical interlock unit: just clip it between the 2 contactors with-out increasing starter width.• BER16C-3 connection set: it assures a safe and simple connection be-tween both contactor main terminals and an electrical interlocking be-tween coil and N.C. built-in auxiliary contact terminals of both contac-tors. Select now easily and quickly your starter in the following pages for coordination type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up to 7. 5 kW.For complete coordination tables with MS116 or MS132, please contact your ABB local sales organization.AC local controlAC remote controlDC local controlDC remote controlPower circuitI > MS116Manual motor starterBEA16-3Connecting linkASASLContactorsBER16C-3 Connection set12
1SBC101273S0201 - Rev. A12/58 ABB MOTOR PROTECTION AND CONTROL—Reversing starters protected by MS116 manual motor startersWith AS contactors - open type version in kit formCoordination type 1 or type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 HzI > Manual motor startersContactorsIECTy peOrder codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc(1)Ty peOrder codeAllowed setting currentAC-3, 400 VRated operationalpowercurrentkWAAAV 50 HzV 60 HzACoordination type 1Coordination type 2Iq = 16 kAIq = 50 kA0.060.2MS116-0.251SAM250000R10020.16...0.252.442424AS09-30-01-201SBL101001R20010.25230230AS09-30-01-261SBL101001R26010.090.3MS116-0.41SAM250000R10030.25...0.403.92424AS09-30-01-201SBL101001R20010.4230230AS09-30-01-261SBL101001R26010.120.44MS116-0.631SAM250000R10040.40...0.636.142424AS09-30-01-201SBL101001R20010.63230230AS09-30-01-261SBL101001R26010.180.6MS116-1.01SAM250000R10050.63...1.0011.52424AS09-30-01-201SBL101001R20011230230AS09-30-01-261SBL101001R26010.250.85MS116-1.01SAM250000R10050.63...1.0011.52424AS09-30-01-201SBL101001R20011230230AS09-30-01-261SBL101001R26010.371.1MS116-1.61SAM250000R10061.00...1.6018.42424AS09-30-01-201SBL101001R20011.6230230AS09-30-01-261SBL101001R26010.551.5MS116-1.61SAM250000R10061.00...1.6018.42424AS09-30-01-201SBL101001R20011.6230230AS09-30-01-261SBL101001R26010.751.9MS116-2.51SAM250000R10071.60...2.5028.752424AS09-30-01-201SBL101001R20012.5230230AS09-30-01-261SBL101001R26011.12.7MS116-4.01SAM250000R10082.50...4.00502424AS09-30-01-201SBL101001R20014230230AS09-30-01-261SBL101001R26011.53.6MS116-4.01SAM250000R10082.50...4.00502424AS09-30-01-201SBL101001R20014230230AS09-30-01-261SBL101001R26012.24.9MS116-6.31SAM250000R10094.00...6.3078.752424AS09-30-01-201SBL101001R20016.3230230AS09-30-01-261SBL101001R260136.5MS116-101SAM250000R10106.30...10.01502424AS12-30-01-201SBL111001R200110230230AS12-30-01-261SBL111001R260148.5MS116-101SAM250000R10106.30...10.01502424AS12-30-01-201SBL111001R200110230230AS12-30-01-261SBL111001R26015.511.5MS116-121SAM250000R10128.00...12.01802424AS12-30-01-201SBL111001R200112230230AS12-30-01-261SBL111001R26017.515.5MS116-161SAM250000R101110.0...16.02402424AS16-30-01-201SBL121001R200115.5230230AS16-30-01-261SBL121001R2601Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.BEA16-3BER16C-3upstream connectiondownstream connectionVM3Main accessoriesTy pe Order codeConnecting link for manual motor starterBEA16-31SBN081006T1000Connection set for reversing starterBER16C-31SBN081012R1000Mechanical interlock unitVM31SBN031005T100012
1SBC101273S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/59—Reversing starters protected by MS116 manual motor startersWith ASL contactors - open type version in kit formCoordination type 1 or type 2, AC-3, 16 or 50 kA, 400 V, 50/60 HzI > Manual motor startersContactorsIECTy peOrder codeCurrent setting rangeMagnetic tripping currentRated control circuit voltage Uc(1)Ty peOrder codeAllowed setting currentAC-3, 400 VRated operationalpowercurrentkWAAAV DCACoordination type 1Coordination type 2Iq = 16 kAIq = 50 kA0.060.2MS116-0.251SAM250000R10020.16...0.252.4424ASL09-30-01-811SBL103001R81010.250.090.3MS116-0.41SAM250000R10030.25...0.403.924ASL09-30-01-811SBL103001R81010.40.120.44MS116-0.631SAM250000R10040.40...0.636.1424ASL09-30-01-811SBL103001R81010.630.180.6MS116-1.01SAM250000R10050.63...1.0011.524ASL09-30-01-811SBL103001R810110.250.85MS116-1.01SAM250000R10050.63...1.0011.524ASL09-30-01-811SBL103001R810110.371.1MS116-1.61SAM250000R10061.00...1.6018.424ASL09-30-01-811SBL103001R81011.60.551.5MS116-1.61SAM250000R10061.00...1.6018.424ASL09-30-01-811SBL103001R81011.60.751.9MS116-2.51SAM250000R10071.60...2.5028.7524ASL09-30-01-811SBL103001R81012.51.12.7MS116-4.01SAM250000R10082.50...4.005024ASL09-30-01-811SBL103001R810141.53.6MS116-4.01SAM250000R10082.50...4.005024ASL09-30-01-811SBL103001R810142.24.9MS116-6.31SAM250000R10094.00...6.3078.7524ASL09-30-01-811SBL103001R81016.336.5MS116-101SAM250000R10106.30...10.015024ASL12-30-01-811SBL113001R81011048.5MS116-101SAM250000R10106.30...10.015024ASL12-30-01-811SBL113001R8101105.511.5MS116-121SAM250000R10128.00...12.018024ASL12-30-01-811SBL113001R8101127.515.5MS116-161SAM250000R101110.0...16.024024ASL16-30-01-811SBL123001R810115.5Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.BEA16-3BER16C-3upstream connectiondownstream connectionVM3Main accessoriesTy pe Order codeConnecting link for manual motor starterBEA16-31SBN081006T1000Connection set for reversing starterBER16C-31SBN081012R1000Mechanical interlock unitVM31SBN031005T100012
1SBC101279S020112/60 ABB MOTOR PROTECTION AND CONTROL—DOL starters protected by MS116 manual motor startersWith AS, ASL contactors - open type version in kit formDirect-on-line startersMS116+ BEA16-3+ AS09, ASL09, AS12, ASL12, AS16, ASL1675 2.95"170 6.69"45 1.77"7 0.28"72.5 2.85"10 0.39"10.1 0.4"5.50.22"35 mm EN/IEC 6071585.6 3.37"45 1.77"5 0.2"35 1.38"17.50.69"10 0.39"6 0.24"176 6.93"4 0.16"ø 4.2 0.17"5 0.2"ø 4.5 0.18"5 0.2"26.251.03"5 0.2"35 1.38"17.50.69"10 0.39"6 0.24"176 6.93"4 0.16"ø 4.2 0.17"5 0.2"ø 4.5 0.18"26.251.03"Main dimensions mm, inches12
1SBC101278S0201 ABB MOTOR PROTECTION AND CONTROL 12/61—Reversing starters protected by MS116 manual motor startersWith AS, ASL contactors - open type version in kit formMS116+ BEA16-3 + BER16C-3 + VM3+ AS09, ASL09, AS12, ASL12, AS16, ASL16Reversing starters10.1 0.40"7 0.28"72.5 2.85"10 0.39"5.50.22"35 mm EN/IEC 6071585.6 3.37"45 1.77"80 3.15"17.50.69"10 0.39"6 0.24"176 6.93"4 0.16"ø 4.2 0.17"5 0.2"ø 4.5 0.18"26.251.03"45 1.77"75 2.95"170 6.69"90 3.54"3 0.12"80 3.15"17.50.69"10 0.39"6 0.24"176 6.93"4 0.16"ø 4.2 0.17"5 0.2"ø 4.5 0.18"5 0.2"26.251.03"5 0.20"5 0.20"Main dimensions mm, inches12
1SBC101275S020112/62 ABB MOTOR PROTECTION AND CONTROL—DOL & reversing starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formAS09-30-10 + T16ApplicationFull voltage direct-on-line and reversing starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.I/InC/Cn6543210710306010080CICoordination typesThe contactor, the short-circuit protection device and the thermal overload relay control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will not be able to then operate without being repaired or having parts replaced.Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or in-stallations and will be able to operate afterwards. The risk of contacts light welding is acceptable.Main technical dataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Ui according to IEC 60947-4-1690 VAir temperature close to the device≤ 60 °CDegree of protectionIP20Switching frequencyThermal overload relays cannot be operated at any arbitrary switching frequency in order to avoid tripping. Applications involving up to 15 operations per hour are acceptable. Higher switching frequencies are permitted if the duty ratio and the motor starting time are allowed for and if the motor's making current does not appreciably exceed 6 times the rated operating current. Please refer to the adjacent diagram for guideline values for the permitted switching frequency.Example: Starting time of the motor: 1 second Duty ratio: 40 % means a permitted switching frequency of max. 60 operating cycles per hour.0102030405060708090100020406080100120140Ta = 0.5 sTa = 3 sTa = 5 sTa = 1.5 sTa = 1 sDuty ratio (%)Switching frequency (ops/h)Duty ratio in %, Ta: motor starting timeNote: Minimum switchover delay of 50 ms must be introduced between respective opening and closing of AC operated reversing contactorsI = currentC = torqueIn = nominal currentCn = nominal torqueAS09-30-01 + BER16C + VM3 + T161SBC101204F00141SBC101205F0014Mounting positionsDirect-on-lineReversingPos. 1Pos. 112
1SBC101275S0201 ABB MOTOR PROTECTION AND CONTROL 12/63Wiring diagramsUVM~13141/L13/L25/L32/T14/T26/T3FR12/T14/T26/T3~MWVU1314KM1A1A21/L13/L25/L32/T14/T26/T3TESTSTOPRESETMA989796956/T34/T22/T1FR1FR19596AMRESETSTOPKM113KM114A1A2 UsN KM1:3/L2KM1:5/L3 UsIFR19596AMRESETSTOPIO UsN KM1:3/L213KM114A2A1KM1KM1:5/L3 UsFR19596AMRESETSTOPKM113KM114A1+A2-I+-FR19596AMRESETSTOPIO13KM114A2-A1+KM1+-131422211314KM2A1A21/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T32221TESTSTOPRESETMA989796956/T34/T22/T1FR1~MWVUUsNKM1:3/L2KM1:5/L3UsIII KM1KM1KM222212221O13KM11413KM214A1A2A1A2KM2STOPRESETMA9695FR1KM1:5/L3UsUsNKM1:3/L2KM213KM11413KM214A1A2A1A2KM1III 21KM22221KM122STOPRESETMA9695FR113KM11413KM214A1+A2-A1+A2-KM1III 21KM22221KM122KM2STOPRESETMA9695FR1+-III KM1KM1KM222212221O13KM11413KM214A1+A1+A2-KM2A2-STOPRESETMA9695FR1+-Power circuitDirect-on-line startersReversing startersPower circuit1-phaseAC remote controlAC remote controlAC local controlAC local controlDC local controlDC local controlDC remote controlDC remote control—DOL & reversing starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formYou can easily assemble a direct-on-line starter by connecting AS or ASL contactors and T16 ther-mal overload relay.You can easily assemble reversing starter thanks to our complete range of accessories:• VM3 mechanical interlock unit: just clip it be-tween the 2 contactors without increasing starter length.• BER16C-3 connection set: it assures a safe and simple reversing connection between both con-tactor main terminals and an electrical inter-locking between coil and N.C. built-in auxiliary contact terminals of both contactors.Select now easily and quickly your starter in the following pages at 400 V, up to 7.5 kW.For complete coordination tables, please contact your ABB local sales organization.Direct-on-line startersReversing startersASASLContactorsT16 Thermal overload relayAS ASL ContactorsBER16C-3 Connection setT16 Thermal overload relayVM3 Mechanical interlock unit12
1SBC101280S0201 - Rev. A12/64ABB MOTOR PROTECTION AND CONTROL—DOL starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formContactors - AC operatedContactorsThermal overload relaysAccessoriesIECRated control circuit voltage Uc(1)Ty peOrder codeSetting rangesTypeOrder codeAC-3, 400 VRated operationalpowercurrentkWAV 50 Hz V 60 HzA ... A48.52424AS09-30-10-201SBL101001R20107.60...10.0T16-101SAZ711201R1043-230230AS09-30-10-261SBL101001R26105.511.52424AS12-30-10-201SBL111001R201010.0...13.0T16-131SAZ711201R1045-230230AS12-30-10-261SBL111001R26107.515.52424AS16-30-10-201SBL121001R201013.0...16.0T16-161SAZ711201R1047-230230AS16-30-10-261SBL121001R2610Contactors - DC operatedIECRated control circuit voltage Uc(1)Ty peOrder codeSetting rangesTypeOrder codeAC-3, 400 VRated operationalpowercurrentkWADCA ... A48.524ASL09-30-10-811SBL103001R81107.60...10.0T16-101SAZ711201R1043-5.511.524ASL12-30-10-811SBL113001R811010.0...13.0T16-131SAZ711201R1045-7.515.524ASL16-30-10-811SBL123001R811013.0...16.0T16-161SAZ711201R1047-Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.see table below for all setting rangesSetting rangesTy peOrder codeA ... A0.10...0.13T16-0.131SAZ711201R10050.13...0.17T16-0.171SAZ711201R10080.17...0.23T16-0.231SAZ711201R10090.23...0.31T16-0.311SAZ711201R10130.31...0.41T16-0.411SAZ711201R10140.41...0.55T16-0.551SAZ711201R10170.55...0.74T16-0.741SAZ711201R10210.74...1.00T16-1.01SAZ711201R10231.00...1.30T16-1.31SAZ711201R10251.30...1.70T16-1.71SAZ711201R10281.70...2.30T16-2.31SAZ711201R10312.30...3.10T16-3.11SAZ711201R10333.10...4.20T16-4.21SAZ711201R10354.20...5.70T16-5.71SAZ711201R10385.70...7.60T16-7.61SAZ711201R10407.60...10.0T16-101SAZ711201R104310.0...13.0T16-131SAZ711201R104513.0...16.0T16-161SAZ711201R104712
1SBC101280S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/65—Reversing starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formContactors - AC operatedContactorsThermal overload relaysAccessories + BER16C-3CA3-10VM3IECRated control circuit voltage Uc(1)Ty peOrder codeSetting rangesTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAV 50 HzV 60 HzA ... A48.52424AS09-30-01-201SBL101001R20017.60...10.0T16-101SAZ711201R1043BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000+1SBN011010T1010230230AS09-30-01-261SBL101001R26015.511.52424AS12-30-01-201SBL111001R200110.0...13.0T16-131SAZ711201R1045BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000+1SBN011010T1010230230AS12-30-01-261SBL111001R26017.515.52424AS16-30-01-201SBL121001R200113.0...16.0T16-161SAZ711201R1047BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000+1SBN011010T1010230230AS16-30-01-261SBL121001R2601Contactors - DC operatedIECRated control circuit voltage Uc(1)Ty peOrder codeSetting rangesTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWADCA ... A48.524ASL09-30-10-811SBL103001R81107.60...10.0T16-101SAZ711201R1043BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000+1SBN011010T10105.511.524ASL12-30-10-811SBL113001R811010.0...13.0T16-131SAZ711201R1045BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000+1SBN011010T10107.515.524ASL16-30-10-811SBL123001R811013.0...16.0T16-161SAZ711201R1047BER16C-3+VM3+2x CA3-101SBN081012R1000+1SBN031005T1000 +1SBN011010T1010Note: for multiple packaging, please contact your ABB local sales organization. (1) Other control voltages see voltage code table.see table below for all setting rangesSetting rangesTy peOrder codeA ... A0.10...0.13T16-0.131SAZ711201R10050.13...0.17T16-0.171SAZ711201R10080.17...0.23T16-0.231SAZ711201R10090.23...0.31T16-0.311SAZ711201R10130.31...0.41T16-0.411SAZ711201R10140.41...0.55T16-0.551SAZ711201R10170.55...0.74T16-0.741SAZ711201R10210.74...1.00T16-1.01SAZ711201R10231.00...1.30T16-1.31SAZ711201R10251.30...1.70T16-1.71SAZ711201R10281.70...2.30T16-2.31SAZ711201R10312.30...3.10T16-3.11SAZ711201R10333.10...4.20T16-4.21SAZ711201R10354.20...5.70T16-5.71SAZ711201R10385.70...7.60T16-7.61SAZ711201R10407.60...10.0T16-101SAZ711201R104310.0...13.0T16-131SAZ711201R104513.0...16.0T16-161SAZ711201R104712
1SBC101288S020112/66 ABB MOTOR PROTECTION AND CONTROL—Star-delta starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formAS09-30-10 + AS09-30-01 + AS09-30-01 + BEY16C-3 + VM3 + CT-SDS + CA3-10 + T16ApplicationStar-delta starting is the most common method to reduce the starting current of a motor.This system can be used on all the squirrel cage motors, which are normally used in delta connection. In this type of starting, it is recommended to choose motors having high start-ing torque i.e. much higher than the resistive torque in order to reach sufficient high speed when the motor is connected in star.When starting:7412356602040801000I /In T/TnIITr T T∆≻I = current In = nominal currentT = torque Tn = nominal torque(delta)(motor)(star)(motor)(resistive torque)Motor speed (%)• Inrush current is reduced to a third of direct starting current• Motor torque is reduced to a third or even less of direct starting torque. Transient current is generated when switching from star to delta connection.During the initial starting phase ("star" connec-tion), the resistive torque of the driven load must remain, irrespective of speed, less than the "star" motor torque until "star-delta" switching occurs.This starting mode is therefore ideal for machines having low starting torque such as pumps, centrifugal compressors, wood-working machines...Precaution• Motor nominal voltage in delta connection must be equal to that of the mains. Example: a motor for 400 V star-delta starting must be designed for 400 V in "delta" connection. Its usual designation is "400 V / 690 V motor". The motor must be constructed with 6 terminal windings• In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching from star to deltaSequenceStarting is a three-stage process:1st stage: "Star" connection - Press the "On" button on the control circuit to close the KM2 "Star" contactor. The KM1 "line" contactor then closes and the motor starts. Countdown of programmed starting time (6 to 10 s) then begins. 2nd stage: "Star" to "Delta" switching - when programmed starting time is over, the KM2 "Star" contactor opens.3rd stage: "Delta" connection - A transition time (or dwelling time) of 50 ms is fixed between opening of the "star" contactor and closing of the "delta" contactor by the use of CT-SDS timer. This prevent short-circuit between "star" and "delta".Main technical dataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Ui according to IEC 60947-4-1690 VAir temperature close to the device≤ 60 °CDegree of protectionIP20Switching frequencySwitching frequency/hour, according to acceleration time and load factor. Respect of the following conditions enables utilization of the starter without excessive overheating of the connections or nuisance tripping of the thermal overload relay.Example:– Switching frequency = 15 starts/hr– Motor starting time "Ta" = 7 s (use 8 s curve)– Maximum load factor = 63 %.This corresponds to a 4-minute operating cycle (15 starts/hr) with 7 seconds acceleration, 2.5 minutes operation and 1.5 minutes rest.0102030405060708090100010203040506070ta = 15 sta = 12 sta = 20 sta = 10 sta = 8 sta = 5 sDuty ratio (%)Switching frequency (ops/h)Duty ratio in %, Ta: acceleration timeMounting positionsPos. 1YΔL 1SBC101207F001412
1SBC101288S0201 ABB MOTOR PROTECTION AND CONTROL 12/67Wiring diagrams2122212223KM2A1A2241/L13/L25/L3132/T14/T26/T314KM3A1A21/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L3132/T14/T26/T314TESTSTOPRESETMA989796956/T34/T22/T1FR1W1V1U1W2V2U2W1V1U1W2V2U2KM2KM3A1A2281817KT UsN KM1:3/L2KM1:5/L3 UsIKT13141314YKM1LKM2KM123KM124A1A2A1A2A1A2KM321222221KM2STOPRESETMA9695FR1KM2KM3A1A2KM1:5/L3 Us UsN KM1:3/L2KM3KM2KT13141314YKM1LKM2KM12818A1A2A1A2A1A22122222123KM12417KTOISTOPRESETMA9695FR1KM2KM3KM3KM2KT13141314YKM1LKM2KM12818A1+A2-A1+A2-A1+A2-A1+A2-2122222123KM12417KTOISTOPRESETMA9695FR1KM2KM3281817KTKM3KM2KTYKM1LI13141314KM2KM123KM124A2-A2-A2-A1+A1+A1+A2-A1+21222221STOPRESETMA9695FR1t1 = adjusted starting timet2 = transition time (50ms)Function diagram Electronic TimerA1-A217-1817-28green LEDt1t2+-+-—Star-delta starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formYou can easily assemble a star-delta starter thanks to our complete range of accessories:• VM3 mechanical interlock unit: just clip it between the 2 contactors without increasing starter length.• BEY16C-3 connection set: it assures a safe and simple con-nection between contactors main terminals and an electri-cal interlocking between coil and N.C. built-in auxiliary con-tact terminals of star and delta contactors.Select now easily and quickly your starter in the following pages at 400 V, up to 11 kW.For complete coordination tables, please contact your ABB local sales organization.AC remote controlAC local controlDC local controlDC remote controlYΔL T16 Thermal overload relayAS ASL ContactorsBEY16C-3 Connection setTimerCA3 1-pole auxiliary contact block12
1SBC101281S0201 - Rev. A12/68ABB MOTOR PROTECTION AND CONTROL—Star-delta starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formContactors - AC operatedYΔL Line contactor KM1Delta contactor KM3Star contactor KM2Thermal overload relaysConnection setsMechanical interlock unitAuxiliary contact blockElectronic timerThe setting current value is: nominalmotor current x 0.58IECRated control circuit voltage Uc(1)Ty peOrder codeTy peOrder codeTy peOrder codeSettingrangesTypeOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAV 50 Hz V 60 HzA ... A7.515.52424AS09-30-10-201SBL101001R2010AS09-30-01-201SBL101001R2001AS09-30-01-201SBL101001R20017.60...10.0T16-101SAZ711201R1043BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"230230AS09-30-10-261SBL101001R2610AS09-30-01-261SBL101001R2601AS09-30-01-261SBL101001R260111222424AS12-30-10-201SBL111001R2010AS12-30-01-201SBL111001R2001AS09-30-01-201SBL101001R200110.0...13.0T16-131SAZ711201R1045BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"230230AS12-30-10-261SBL111001R2610AS12-30-01-261SBL111001R2601AS09-30-01-261SBL101001R2601Contactors - DC operatedIECRated control circuit voltage Uc(1)Ty peOrder codeTy peOrder codeTy peOrder codeSettingrangesTypeOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWADCA ... A7.515.524ASL09-30-10-811SBL103001R8110ASL09-30-01-811SBL103001R8101ASL09-30-01-811SBL103001R81017.60...10.0T16-101SAZ711201R1043BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"112224ASL12-30-10-811SBL113001R8110ASL12-30-01-811SBL113001R8101ASL09-30-01-811SBL103001R810110.0...13.0T16-131SAZ711201R1045BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.see table below for all setting ranges12
1SBC101281S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/69Contactors - AC operatedYΔL Line contactor KM1Delta contactor KM3Star contactor KM2Thermal overload relaysConnection setsMechanical interlock unitAuxiliary contact blockElectronic timer The setting current value is: nominal motor current x 0.58IECRated control circuit voltage Uc(1)Ty peOrder codeTy peOrder codeTy peOrder codeSetting rangesTy peOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWAV 50 HzV 60 HzA ... A7.515.52424AS09-30-10-201SBL101001R2010AS09-30-01-201SBL101001R2001AS09-30-01-201SBL101001R20017.60...10.0T16-101SAZ711201R1043BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"230230AS09-30-10-261SBL101001R2610AS09-30-01-261SBL101001R2601AS09-30-01-261SBL101001R260111222424AS12-30-10-201SBL111001R2010AS12-30-01-201SBL111001R2001AS09-30-01-201SBL101001R200110.0...13.0T16-131SAZ711201R1045BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"230230AS12-30-10-261SBL111001R2610AS12-30-01-261SBL111001R2601AS09-30-01-261SBL101001R2601Contactors - DC operatedIECRated control circuit voltage Uc(1)Ty peOrder codeTy peOrder codeTy peOrder codeSetting rangesTy peOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3, 400 VRated operationalpowercurrentkWADCA ... A7.515.524ASL09-30-10-811SBL103001R8110ASL09-30-01-811SBL103001R8101ASL09-30-01-811SBL103001R81017.60...10.0T16-101SAZ711201R1043BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"112224ASL12-30-10-811SBL113001R8110ASL12-30-01-811SBL113001R8101ASL09-30-01-811SBL103001R810110.0...13.0T16-131SAZ711201R1045BEY16C-3+VM31SBN081018R2000+1SBN031005T1000KM1: 1 x CA3-10KM2: 1 x CA3-101SBN011010T10101SBN011010T1010CT-SDS...see "Ordering Details"Note: for multiple packaging, please contact your ABB local sales organization.(1) Other control voltages see voltage code table.see table below for all setting ranges—Star-delta starters protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formOrdering details - Main accessoriesTy peOrder codePkgqtyWeight(1 pce)kgElectronic timer* 28-48 V DCCT-SDS.22S1SVR730210R330010.11424-240 V AC380-440 V ACCT-SDS.23S1SVR730211R230010.118* 7 time ranges (0.05 s - 10 min), 50 ms transition time, 2 n/o contacts, 3 LEDsCT-SDS...Setting rangesTy peOrder codeA ... A0.10...0.13T16-0.131SAZ711201R10050.13...0.17T16-0.171SAZ711201R10080.17...0.23T16-0.231SAZ711201R10090.23...0.31T16-0.311SAZ711201R10130.31...0.41T16-0.411SAZ711201R10140.41...0.55T16-0.551SAZ711201R10170.55...0.74T16-0.741SAZ711201R10210.74...1.00T16-1.01SAZ711201R10231.00...1.30T16-1.31SAZ711201R10251.30...1.70T16-1.71SAZ711201R10281.70...2.30T16-2.31SAZ711201R10312.30...3.10T16-3.11SAZ711201R10333.10...4.20T16-4.21SAZ711201R10354.20...5.70T16-5.71SAZ711201R10385.70...7.60T16-7.61SAZ711201R10407.60...10.0T16-101SAZ711201R104310.0...13.0T16-131SAZ711201R104513.0...16.0T16-161SAZ711201R104712
1SBC101293S020112/70ABB MOTOR PROTECTION AND CONTROL—Protected by thermal overload relaysWith AS, ASL contactors - open type version in kit formDirect-on-line startersReversing startersStar-delta starters35 mmEN/IEC 6071568 2.68"45 1.77"128.5 5.06"5.5 0.22"72.5 2.85"7 0.28"10 0.39"17.3 0.68"70.8 2.79"5.3 0.21"50 1.97"60 2.36"35 1.38"ø 4.2 0.17"2 xM4 8-32 UNC5 0.2"ø 4.2 0.17"2 xM4 8-32 UNC60 2.36"35 1.38"5 0.2"ACDC60 2.36"80 3.15"50 1.97"60 2.36"80 3.15"35 mmEN/IEC 6071517.3 0.68"70.8 2.79"5.3 0.21"68 2.68"90 3.54"136.5 5.37"67.3 2.65"72.5 2.85"7 0.28"10 0.39"5.5 0.22"2 xM4 8-32 UNCø 4.20.17"ø 4.20.17"2 xM4 8-32 UNCACDCACDC35 mmEN/IEC 6071550 1.97"60 2.36"125 4.92"ø 4.20.17"ø 4.20.17"60 2.36"125 4.92"136.5 5.37"22.50.89"5.9 0.23"157.5 6.2"2 xM4 8-32 UNC2 xM4 8-32 UNC7 0.28"72.5 2.85"103.7 4.08"68 2.68"85.6 3.37"5.50.22"17.3 0.68"70.8 2.79"5.3 0.21"Main dimensions mm, inches12
—Reversing starters protected by thermal overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF190, AF205 + BER205-4, VM19+ TA200DU thermal overload relay210 8.27"152 5.98"395 15.55"3570 2.76"M5 10-24 UNC12 X82 3.23"37 1.46"50 1.97"165 6.50"81.5 3.21"1.38"351.38"1SFC101159C0201 ABB MOTOR PROTECTION AND CONTROL 12/7112
—DOL starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.45 1.77"158.9 6.26"86 3.39"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"9.20.36"75.7 2.98"79.8 3.14"35 1.38"70 2.76"60 2.36"5 0.20"5 0.20"ø 4.2 0.17"2 xM4 8-32 UNC45 1.77"172.3 6.78"86 3.39"82.5 3.25"86 3.39"80 3.15"10 0.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26, AF30, AF38+ EF45 electronic overload relayAF09, AF12, AF16, AF26, AF30, AF38+ EF electronic overload relayAF09, AF12, AF16+ EF19 electronic overload relay45 1.77"152.4 6.00"77 3.03"76.8 3.02"73.3 2.89"71 2.80"5.5 0.22"35 mm EN/IEC 6071510 0.39"17.4 0.69"5.5 0.22"45 1.77"155.2 6.11"86 3.39"76.3 3.00"79.8 3.14"80 3.15"10 0.39"20.4 0.80"35 mm EN/IEC 607155.5 0.22"5.5 0.22"AF26, AF30, AF38+ EF19 electronic overload relay1SBC101950S020112/72ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF40, AF52, AF65+ EF65 electronic overload relay45 1.77"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC2 x2 xAF80, AF96+ EF96 electronic overload relayø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC2 x60 2.36"AF40, AF52, AF65+ EF65 electronic overload relay111 4.37"7 0.28"55 2.17"10 0.39"35 mm EN/IEC 607155.5 0.22"237 9.33"70 2.76"106.8 4.20"110.6 4.35"5.4 0.21"AF80, AF96+ EF96 electronic overload relay70 2.76"116 4.57"7 0.28"10 0.39"5.5 0.22"237 9.33"106.8 4.20"110.6 4.35"5.4 0.21"35 x 15 mm EN/IEC 607151SBC101951S0201 ABB MOTOR PROTECTION AND CONTROL 12/7312
—DOL starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF190, AF205-30-11 + EF205 electronic overload relay105 4.13"342 13.46"152 5.98"35.5 1.40"5 0.20"35 1.38"35 1.38"17.5 0.69"8.5 0.33"123 4.84"5 0.20"10 0.39"35 1.38"20.50.81"112 4.42"35 1.39"M5 10-24 UNC8 x165 6.50"AF190, AF205 + EF205 electronic overload relayAF116, AF140, AF146-30-11(B) + EF146 electronic overload relay126 4.96"105 4.13"90 3.54"270 10.63"17 0.67"3 0.12"100 3.94"46 1.81"94.7 3.73"30 1.18"37 1.46"M4 8-32 UNCM5 10-24 UNC6 x2 x21.50.85"AF116, AF140, AF146-30-11(B) + EF146 electronic overload relay1SFC101161C02011 2/ 74ABB MOTOR PROTECTION AND CONTROL12
—DOL starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF265, AF305, AF370-30-11+ EF370 electronic overload relay385 15.16"140 5.51"180 7.09"123 4.84"44 1.73"43.8 1.72"20 1.79"14 0.55"ø 11 0.43"35.5 1.40"5 0.20"35 1.20"5 0.20"112 4.41"29 1.14"35 1.38"43.75 1.72"M5 10-24 UNC8 x187 7.36"1SFC101157C0201 ABB MOTOR PROTECTION AND CONTROL 12/7512
—Reversing starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesNote: contactor lateral distance to grounded component 2 mm 0.08" min.AF26, AF30, AF38+ BER38-4, VEM4, CA4-10 + EF19 electronic overload relayAF26, AF30, AF38+ BER38-4, VEM4, CA4-10 + EF45 electronic overload relay90 3.54"35 mm EN/IEC 60715102.5 4.04"71 2.80"5.5 0.22"5.5 0.22"76.8 3.02"73.3 2.89"17.4 0.69"100.39"163 6.42"60 2.36"ø 4.2 0.17"80 3.15"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC90 3.54"100.39"166.5 6.56"102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 mm EN/IEC 607155.5 0.22"90 3.54"76.3 3.00"79.8 3.14"20.4 0.80"166 6.54"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"119.5 4.70"82.5 3.25"86 3.39"90 3.54"80 3.15"100.39"35 mm EN/IEC 607155.5 0.22"5.5 0.22"119.5 4.70"183.5 7.22"AF09, AF12, AF16+ BER16-4, VEM4+ EF19 electronic overload relayAF09, AF12, AF16, AF26, AF30, AF381SBC101952S020112/76ABB MOTOR PROTECTION AND CONTROL12
—Reversing starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF40, AF52, AF65+ BER65-4, VM96-4+ EF65 electronic overload relayAF80, AF96+ BER96-4, VM96-4+ EF96 electronic overload relayAF80, AF96+ BER96-4, VM96-4+ EF96 electronic overload relayAF40, AF52, AF65+ BER65-4, VM96-4+ EF65 electronic overload relay100.39"5.5 0.22"144 5.67"111 4.37"106.8 4.20"110.6 4.35"5.4 0.21"117.5 4.63"251 9.88"35 x 15 mm EN/IEC 6071535 x 7.5 mm EN/IEC 60715116 4.57"100.39"5.5 0.22"149 5.87"35 x 15 mm EN/IEC 60715140 5.51"106.8 4.20"110.6 4.35"5.4 0.21"251 9.88"100 3.94"ø 6.4 0.25"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNC130 5.12"ø 6.4 0.25"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNC1SBC101953S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/7712
—Reversing starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF116, AF140, AF146 + BER140-4, VM19+ EF146 electronic overload relay180 7.09"126 4.96"281.5 11.08"60 2.36"10x30 1.18"M4 8-32 UNC100 3.94"30 1.18"94.7 3.73"37 1.46"M5 10-24 UNC2x21.50.85"43.8 1.72"1SFC101162C020112/78ABB MOTOR PROTECTION AND CONTROL12
—Reversing starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF190, AF205 + BER205-4, VM19+ EF205 electronic overload relay210 8.27"152 5.98"425 16.73"3570 2.76"M5 10-24 UNC12 X112 4.42"165 6.50"1.38"351.38"76 2.99"1SFC101163C0201 ABB MOTOR PROTECTION AND CONTROL 12/7912
—Reversing starters protected by electronic overload relaysWith AF contactors - open type version in kit formMain dimensions mm, inchesAF265, AF305, AF370 + BER370-4, VM19+ EF370 electronic overload relay280 11.02"180 7.09"477.5 18.80"43.7543.7596.25 3.79"M5 10-24 UNC12 X112 4.41"35187 7.36"90.5 3.56"1.38"1.72"1.72"1SFC101160C020112/80ABB MOTOR PROTECTION AND CONTROL12
—Notes ABB MOTOR PROTECTION AND CONTROL 12/8112
12/82 ABB MOTOR PROTECTION AND CONTROL—Star-delta starters protected by overload relaysWith AF contactors - Open type version in kit formApplicationStar-delta starting is the most common method to reduce the starting current of a motor.This system can be used on all the squirrel cage motors, which are normally used in delta connection. In this type of starting, it is recommended to choose motors having high start-ing torque i.e. much higher than the resistive torque in order to reach sufficient high speed when the motor is connected in star.I/InT/Tn6543210720406010080Tr I T IT∆(delta)(motor)(star)(motor)(resistive torque)Motor speed (%)When starting:• Inrush current is reduced to a third of direct starting current• Motor torque is reduced to a third or even less of direct starting torque. Transient current is generated when switching from star to delta connection.During the initial starting phase ("star" connec-tion), the resistive torque of the driven load must remain, irrespective of speed, less than the "star" motor torque until "star-delta" switching occurs.This starting mode is therefore ideal for ma-chines having low starting torque such as pumps, centrifugal compressors, wood-working machines...I = currentT = torqueIn = nominal currentTn = nominal torquePrecaution• Motor nominal voltage in delta connection must be equal to that of the mains. Example: a motor for 400 V star-delta starting must be designed for 400 V in "delta" connection. Its usual designation is "400 V / 690 V motor". The motor must be constructed with 6 terminal windings• In order to prevent a high current peak, at least 85 % of nominal speed must be reached be-fore switching from star to deltaSequenceStarting is a three-stage process:1st stage: "Star" connection - Press the "On" button on the control circuit to close the KM2 "Star" contactor. The KM1 "line" contactor then closes and the motor starts. Countdown of programmed starting time (6 to 10 s) then begins. 2nd stage: "Star" to "Delta" switching - when programmed starting time is over, the KM2 "Star" contactor opens.3rd stage: "Delta" connection - Thanks to AF contactors, a transition time (or dwelling time) of 50 ms is already integrated between the opening of the "star" contactor and closing of the "delta" contactor. Conclusion: An on-delay timer without dwelling time (e.g.: CT-ERS.21S or TEF4-ON) is enough to countdown the programmed starting time (6 to 10 s) during "Star connection". The use of a star-delta timer including a dwelling time is not permitted. Main Technical DataStandardsIEC 60947-4-1 / EN 60947-4-1Rated operational voltage Ue max.690 V - 50/60 HzRated insulation voltage Uiacc. to IEC 60947-4-1690 Vacc. to UL / CSA600 VAmbient air temperatureClose to the device≤ 60 °C (TF42: 38 A above ≤ 50 °C)Degree of protectionIP20Switching frequencyRefer to "Switching frequency diagrams" pageMounting positionsPos. 11SFC101104V00011SFC101103V0001AF140-30-11 + AF140-30-11 + AF140-30-11 + BEY140-4 + VM19 + EF146AF16-30-10 + AF16-30-10 + AF09-30-10 + BEY16-4 + VEM4 + TF42YΔL 1SBC101956S020112
ABB MOTOR PROTECTION AND CONTROL 12/83Star-delta starters for AF09 ... AF38Star-delta starters for AF116 ... AF370—Star-delta starters protected by overload relaysWith AF contactors - Open type version in kit formYou can easily assemble star-delta starter thanks to our complete range of accessories:•For AF09 ... AF38, use VEM4mechanical and electrical interlockset without increasing starterwidth. It includes: - VM4 mechanical interlock unitand 2 fixing clips - VE4 electrical interlock block with A2-A2 connection.•For AF40 ... AF370, use VMmechanical interlock unit andadditional auxiliary contact blocksfor electrical interlocking.•BEY..-4 connection set: it assuresa safe and simple connectionbetween both contactor mainterminals.Select now easily and quickly your starter in the following pages at 400 V, up to 200 kW.KM1KM3KM2AF contactorwith built-in cable clampsAF contactorwith built-in cable clampsVM Mechanical interlock unitB E Y. .- 4 Connection setB E Y. .- 4 Connection setT F/ TA Thermal overload relay EFElectronic overload relayFor the full coordination tables:www.abb.com/lowvoltage then go to the right menu: "Support", select: "Online Product Selec-tion Tools" then select "Coordination Tables for motor protection"TF42 Thermal overload relayEF19, EF45 Electronic overload relayB E Y. .- 4 Connection setVE4 Electrical interlock blockFixing clipA2A2AF09 ... AF38 ContactorsVM4 Mechanical interlock unitYΔL YΔL B E Y. .- 4 Connection set1SBC101956S020112
12/84ABB MOTOR PROTECTION AND CONTROL—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formYΔL Line contactor KM1Delta contactor KM3Star contactor KM2Thermal overload relays (2)Electronic timers (3)AccessoriesCT- ERSTEF4-ONConnectionsetsMechanicaland electricalinterlock setsVEM4BE Y..- 4Auxiliary contact blocksCA4IECControl voltage Uc min. ... Uc max.(1)TypeOrder codeTy peOrder codeTy peOrder codeSettingrangesTy peOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3Rated powerRated current40 0 V400 VkWAV 50/60 HzV DCA7.515.524...60 20...60AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R21107.60...10.0TF42-101SAZ721201R1043orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310112224...60 20...60AF12Z-30-10-211SBL156001R2110AF12Z-30-10-211SBL156001R2110AF09Z-30-10-211SBL136001R211010.0...13.0TF42-131SAZ721201R1045orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF12-30-10-131SBL157001R1310AF12-30-10-131SBL157001R1310AF09-30-10-131SBL137001R1310152924...60 20...60AF16Z-30-10-211SBL176001R2110AF16Z-30-10-211SBL176001R2110AF09Z-30-10-211SBL136001R211016.0...20.0TF42-201SAZ721201R1049orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF16-30-10-131SBL177001R1310AF16-30-10-131SBL177001R1310AF09-30-10-131SBL137001R131018.53524...60 20...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R210020.0...24.0TF42-241SAZ721201R1051orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300224124...60 20...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R210020.0...24.0TF42-241SAZ721201R1051orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300254724...60 20...60AF30Z-30-00-211SBL276001R2100AF30Z-30-00-211SBL276001R2100AF26Z-30-00-211SBL236001R210024.0...29.0TF42-291SAZ721201R1052orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF30-30-00-131SBL277001R1300AF30-30-00-131SBL277001R1300AF26-30-00-131SBL237001R1300376624...60 20...60AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R110030.0...40.0TF65-401SAZ811201R1003orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-011SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300458024...60 20...60AF52-30-00-111SBL367001R1100AF52-30-00-111SBL367001R1100AF40-30-00-111SBL347001R110036.0...47.0TF65-471SAZ811201R1004orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF52-30-00-131SBL367001R1300AF52-30-00-131SBL367001R1300AF40-30-00-131SBL347001R1300559724...60 20...60AF65-30-00-111SBL387001R1100AF65-30-00-111SBL387001R1100AF40-30-00-111SBL347001R110050.0...60.0TF65-601SAZ811201R1006orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF65-30-00-131SBL387001R1300AF65-30-00-131SBL387001R1300AF40-30-00-131SBL347001R13007513224...60 20...60AF80-30-00-111SBL397001R1100AF80-30-00-111SBL397001R1100AF52-30-00-111SBL367001R110065.0...78.0TF96-781SAZ911201R1004orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300AF80-30-00-131SBL397001R1300AF52-30-00-131SBL367001R13009016024...60 20...60AF96-30-00-111SBL407001R1100AF96-30-00-111SBL407001R1100AF65-30-00-111SBL387001R110084.0...96.0TF96-961SAZ911201R1006orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF96-30-00-131SBL407001R1300AF96-30-00-131SBL407001R1300AF65-30-00-131SBL387001R130011019524...60 20...60AF116-30-11-11 1SFL427001R1111AF116-30-11-11 1SFL427001R1111AF116-30-11-11 (4)1SFL427001R1111100...135TF140DU-1351SAZ431201R1003CT-ERS.21S1SVR730100R0300+BEY140-4VM191SFN084413R10001SFN030300R1000--100...250100...250AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R131113223024...60 20...60AF140-30-11-111SFL447001R1111AF140-30-11-111SFL447001R1111AF116-30-11-11 1SFL427001R1111100...135TF140DU-1351SAZ431201R1003CT-ERS.21S1SVR730100R0300+BEY140-4VM191SFN084413R10001SFN030300R1000--100...250100...250AF140-30-11-131SFL447001R1311AF140-30-11-131SFL447001R1311AF116-30-11-131SFL427001R131116028024...60 20...60AF190-30-11-111SFL487002R1111AF190-30-11-111SFL487002R1111AF140-30-11-111SFL447001R1111130...175TA200DU-1751SAZ421201R1005CT-ERS.21S1SVR730100R0300+BEY190-4VM140/1901SFN084813R10001SFN034403R1000--100...250100...250AF190-30-11-131SFL487002R1311AF190-30-11-131SFL487002R1311AF140-30-11-131SFL447001R131112
1SBC101959S0201ABB MOTOR PROTECTION AND CONTROL 12/85YΔL Line contactor KM1Delta contactor KM3Star contactor KM2Thermal overload relays (2)Electronic timers (3)AccessoriesCT- ERSTEF4-ONConnectionsetsMechanical and electrical interlock setsVEM4BE Y..- 4Auxiliary contact blocksCA4IECControl voltageUc min. ... Uc max.(1)TypeOrder codeTy peOrder codeTy peOrder codeSetting rangesTypeOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3Rated powerRated current400 V 400 VkWAV 50/60 HzV DCA7.515.524...6020...60AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R21107.60...10.0TF42-101SAZ721201R1043orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310112224...6020...60AF12Z-30-10-211SBL156001R2110AF12Z-30-10-211SBL156001R2110AF09Z-30-10-211SBL136001R211010.0...13.0TF42-131SAZ721201R1045orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF12-30-10-131SBL157001R1310AF12-30-10-131SBL157001R1310AF09-30-10-131SBL137001R1310152924...6020...60AF16Z-30-10-211SBL176001R2110AF16Z-30-10-211SBL176001R2110AF09Z-30-10-211SBL136001R211016.0...20.0TF42-201SAZ721201R1049orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF16-30-10-131SBL177001R1310AF16-30-10-131SBL177001R1310AF09-30-10-131SBL137001R131018.53524...6020...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R210020.0...24.0TF42-241SAZ721201R1051orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300224124...6020...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R210020.0...24.0TF42-241SAZ721201R1051orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300254724...6020...60AF30Z-30-00-211SBL276001R2100AF30Z-30-00-211SBL276001R2100AF26Z-30-00-211SBL236001R210024.0...29.0TF42-291SAZ721201R1052orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF30-30-00-131SBL277001R1300AF30-30-00-131SBL277001R1300AF26-30-00-131SBL237001R1300376624...6020...60AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R110030.0...40.0TF65-401SAZ811201R1003orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-011SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300458024...6020...60AF52-30-00-111SBL367001R1100AF52-30-00-111SBL367001R1100AF40-30-00-111SBL347001R110036.0...47.0TF65-471SAZ811201R1004orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF52-30-00-131SBL367001R1300AF52-30-00-131SBL367001R1300AF40-30-00-131SBL347001R1300559724...6020...60AF65-30-00-111SBL387001R1100AF65-30-00-111SBL387001R1100AF40-30-00-111SBL347001R110050.0...60.0TF65-601SAZ811201R1006orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF65-30-00-131SBL387001R1300AF65-30-00-131SBL387001R1300AF40-30-00-131SBL347001R13007513224...6020...60AF80-30-00-111SBL397001R1100AF80-30-00-111SBL397001R1100AF52-30-00-111SBL367001R110065.0...78.0TF96-781SAZ911201R1004orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300AF80-30-00-131SBL397001R1300AF52-30-00-131SBL367001R13009016024...6020...60AF96-30-00-111SBL407001R1100AF96-30-00-111SBL407001R1100AF65-30-00-111SBL387001R110084.0...96.0TF96-961SAZ911201R1006orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01 KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF96-30-00-131SBL407001R1300AF96-30-00-131SBL407001R1300AF65-30-00-131SBL387001R130011019524...6020...60AF116-30-11-11 1SFL427001R1111AF116-30-11-11 1SFL427001R1111AF116-30-11-11 (4)1SFL427001R1111100...135TF140DU-1351SAZ431201R1003CT-ERS.21S1SVR730100R0300+BEY140-4 VM191SFN084413R10001SFN030300R1000--100...250100...250AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R131113223024...6020...60AF140-30-11-111SFL447001R1111AF140-30-11-111SFL447001R1111AF116-30-11-11 1SFL427001R1111100...135TF140DU-1351SAZ431201R1003CT-ERS.21S1SVR730100R0300+BEY140-4 VM191SFN084413R10001SFN030300R1000--100...250100...250AF140-30-11-131SFL447001R1311AF140-30-11-131SFL447001R1311AF116-30-11-131SFL427001R131116028024...6020...60AF190-30-11-111SFL487002R1111AF190-30-11-111SFL487002R1111AF140-30-11-111SFL447001R1111130...175TA200DU-1751SAZ421201R1005CT-ERS.21S1SVR730100R0300+BEY190-4VM140/1901SFN084813R10001SFN034403R1000--100...250100...250AF190-30-11-131SFL487002R1311AF190-30-11-131SFL487002R1311AF140-30-11-131SFL447001R1311Uc = 24...240 V50/60 Hz or DC12
12/86ABB MOTOR PROTECTION AND CONTROL12/86ABB MOTOR PROTECTION AND CONTROL—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formYΔL Line contactor KM1Delta contactor KM3Star contactor KM2Electronic overload relays (2)Electronic timers (3)AccessoriesCT-ERSTEF4-ONConnectionsetsMechanicaland electricalinterlock setsVEM4BE Y..- 4Auxiliary contact blocksCA4IECControl voltage Uc min. ... Uc max.(1)TypeOrder codeTy peOrder codeTy peOrder codeSettingrangesTypeOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3Rated powerRated current400 V 400 VkWAV 50/60 HzV DCA7.515.524...60 20...60AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310112224...60 20...60AF12Z-30-10-211SBL156001R2110AF12Z-30-10-211SBL156001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF12-30-10-131SBL157001R1310AF12-30-10-131SBL157001R1310AF09-30-10-131SBL137001R1310152924...60 20...60AF16Z-30-10-211SBL176001R2110AF16Z-30-10-211SBL176001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R20001SBN030111R1000--100...250100...250AF16-30-10-131SBL177001R1310AF16-30-10-131SBL177001R1310AF09-30-10-131SBL137001R131018.53524...60 20...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300224124...60 20...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300254724...60 20...60AF30Z-30-00-211SBL276001R2100AF30Z-30-00-211SBL276001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF30-30-00-131SBL277001R1300AF30-30-00-131SBL277001R1300AF26-30-00-131SBL237001R1300376624...60 20...60AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-101 x CA4-01KM3 : 1 x CA4-011SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300458024...60 20...60AF52-30-00-111SBL367001R1100AF52-30-00-111SBL367001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF52-30-00-131SBL367001R1300AF52-30-00-131SBL367001R1300AF40-30-00-131SBL347001R1300559724...60 20...60AF65-30-00-111SBL387001R1100AF65-30-00-111SBL387001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF65-30-00-131SBL387001R1300AF65-30-00-131SBL387001R1300AF40-30-00-131SBL347001R13007513224...60 20...60AF80-30-00-111SBL397001R1100AF80-30-00-111SBL397001R1100AF52-30-00-111SBL367001R110036...100EF96-1001SAX341001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-101 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300AF80-30-00-131SBL397001R1300AF52-30-00-131SBL367001R13009016024...60 20...60AF96-30-00-111SBL407001R1100AF96-30-00-111SBL407001R1100AF65-30-00-111SBL387001R110036...100EF96-1001SAX341001R1101orCT-ERS.21STEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF96-30-00-131SBL407001R1300AF96-30-00-131SBL407001R1300AF65-30-00-131SBL387001R130011019524...60 20...60AF116-30-11-11 1SFL427001R1111AF116-30-11-11 1SFL427001R1111AF116-30-11-11 (4)1SFL427001R111154...150EF146-1501SAX351001R1101CT-ERS.21S1SVR730100R0300+BEY140-4VM191SFN084413R10001SFN030300R1000--100...250100...250AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R131113223024...60 20...60AF140-30-11-111SFL447001R1111AF140-30-11-111SFL447001R1111AF116-30-11-11 1SFL427001R111154...150EF146-1501SAX351001R1101CT-ERS.21S1SVR730100R0300+BEY140-4VM191SFN084413R10001SFN030300R1000--100...250100...250AF140-30-11-131SFL447001R1311AF140-30-11-131SFL447001R1311AF116-30-11-131SFL427001R131116028024...60 20...60AF190-30-11-111SFL487002R1111AF190-30-11-111SFL487002R1111AF140-30-11-111SFL447001R111163...210 EF205-2101SAX531001R1101CT-ERS.21S1SVR730100R0300+BEY190-4VM140/1901SFN084813R10001SFN034403R1000--100...250100...250AF190-30-11-131SFL487002R1311AF190-30-11-131SFL487002R1311AF140-30-11-131SFL447001R131120035024...60 20...60AF205-30-11-111SFL527002R1111AF205-30-11-111SFL527002R1111AF190-30-11-111SFL487002R111163...210 EF205-2101SAX531001R1101CT-ERS.21S1SVR730100R0300+BEY205-4VM191SFN085213R10001SFN030300R1000--100...250100...250AF205-30-11-131SFL527002R1311AF205-30-11-131SFL527002R1311AF190-30-11-131SFL487002R131125043024...60 20...60AF265-30-11-111SFL547002R1111AF265-30-11-111SFL547002R1111AF205-30-11-111SFL527002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY265-4VM205/2651SFN085413R10001SFN035203R1000--100...250100...250AF265-30-11-131SFL547002R1311AF265-30-11-131SFL547002R1311AF205-30-11-131SFL527002R131131554024...60 20...60AF370-30-11-111SFL607002R1111AF370-30-11-111SFL607002R1111AF265-30-11-111SFL547002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY370-4VM191SFN085813R10001SFN030300R1000--100...250100...250AF370-30-11-131SFL607002R1311AF370-30-11-131SFL607002R1311AF265-30-11-131SFL547002R131135561024...60 20...60AF370-30-11-111SFL607002R1111AF370-30-11-111SFL607002R1111AF305-30-11-111SFL587002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY370-4VM191SFN085813R10001SFN030300R1000--100...250100...250AF370-30-11-131SFL607002R1311AF370-30-11-131SFL607002R1311AF305-30-11-131SFL587002R1311(1) AF09 ... AF370: ambient temperature ≤ 60 °C. (2) The setting current value is: nominal motor current x 0.58. Overload relay type given for 400 V - AC-3.For other voltage, select overload relay type according to required nominal motor current x 0.58.(3) On-delay timer without dwelling-time (e.g.: side-mounted CT-ERS.21S or front-mounted TEF4-ON) is enough to countdown the programmed starting timeduring "Star connection". In case of use of front-mounted TEF4-ON on-delay timer, mount on KM1 contactor AF26 ... AF96 a side-mounted CAL4-11 auxiliary contact blockinstead of CA4-10 auxiliary contact block.(4) AF80 can also be used, but no connection set and mechanical interlock is available for this combination.12
ABB MOTOR PROTECTION AND CONTROL 12/87ABB MOTOR PROTECTION AND CONTROL 12/871SBC101960S0201YΔL Line contactor KM1Delta contactor KM3Star contactor KM2Electronic overload relays (2)Electronic timers (3)AccessoriesCT-ERSTEF4-ONConnectionsetsMechanical and electrical interlock setsVEM4BE Y..- 4Auxiliary contact blocksCA4IECControl voltageUc min. ... Uc max.(1)TypeOrder codeTy peOrder codeTy peOrder codeSetting rangesTypeOrder codeTy peOrder codeTy peOrder codeTy peOrder codeAC-3Rated powerRated current400 V 400 VkWAV 50/60 HzV DCA7.515.524...6020...60AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310AF09-30-10-131SBL137001R1310112224...6020...60AF12Z-30-10-211SBL156001R2110AF12Z-30-10-211SBL156001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF12-30-10-131SBL157001R1310AF12-30-10-131SBL157001R1310AF09-30-10-131SBL137001R1310152924...6020...60AF16Z-30-10-211SBL176001R2110AF16Z-30-10-211SBL176001R2110AF09Z-30-10-211SBL136001R21105.70...18.9 EF19-18.91SAX121001R1105orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY16-4VEM41SBN081313R2000 1SBN030111R1000--100...250100...250AF16-30-10-131SBL177001R1310AF16-30-10-131SBL177001R1310AF09-30-10-131SBL137001R131018.53524...6020...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300224124...6020...60AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300AF26-30-00-131SBL237001R1300254724...6020...60AF30Z-30-00-211SBL276001R2100AF30Z-30-00-211SBL276001R2100AF26Z-30-00-211SBL236001R21009.00...30.0EF45-301SAX221001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY38-4VEM41SBN082713R20001SBN030111R1000KM1 : 1 x CA4-10KM2 : 1 x CA4-101SBN010110R10101SBN010110R1010100...250100...250AF30-30-00-131SBL277001R1300AF30-30-00-131SBL277001R1300AF26-30-00-131SBL237001R1300376624...6020...60AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-101 x CA4-01KM3 : 1 x CA4-011SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300AF40-30-00-131SBL347001R1300458024...6020...60AF52-30-00-111SBL367001R1100AF52-30-00-111SBL367001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF52-30-00-131SBL367001R1300AF52-30-00-131SBL367001R1300AF40-30-00-131SBL347001R1300559724...6020...60AF65-30-00-111SBL387001R1100AF65-30-00-111SBL387001R1100AF40-30-00-111SBL347001R110025...70EF65-701SAX331001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY65-4VM96-41SBN083413R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF65-30-00-131SBL387001R1300AF65-30-00-131SBL387001R1300AF40-30-00-131SBL347001R13007513224...6020...60AF80-30-00-111SBL397001R1100AF80-30-00-111SBL397001R1100AF52-30-00-111SBL367001R110036...100EF96-1001SAX341001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-101 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF80-30-00-131SBL397001R1300AF80-30-00-131SBL397001R1300AF52-30-00-131SBL367001R13009016024...6020...60AF96-30-00-111SBL407001R1100AF96-30-00-111SBL407001R1100AF65-30-00-111SBL387001R110036...100EF96-1001SAX341001R1101orCT-ERS.21S TEF4-ON1SVR730100R03001SBN020112R1000+BEY96-4VM96-41SBN083913R20001SBN033405T1000KM1 : 1 x CA4-10 (3) KM2 : 1 x CA4-10 1 x CA4-01KM3 : 1 x CA4-01 1SBN010110R10101SBN010110R10101SBN010110R10011SBN010110R1001100...250100...250AF96-30-00-131SBL407001R1300AF96-30-00-131SBL407001R1300AF65-30-00-131SBL387001R130011019524...6020...60AF116-30-11-11 1SFL427001R1111AF116-30-11-11 1SFL427001R1111AF116-30-11-11 (4)1SFL427001R111154...150EF146-1501SAX351001R1101CT-ERS.21S1SVR730100R0300+BEY140-4 VM191SFN084413R10001SFN030300R1000--100...250100...250AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R1311AF116-30-11-131SFL427001R131113223024...6020...60AF140-30-11-111SFL447001R1111AF140-30-11-111SFL447001R1111AF116-30-11-11 1SFL427001R111154...150EF146-1501SAX351001R1101CT-ERS.21S1SVR730100R0300+BEY140-4 VM191SFN084413R10001SFN030300R1000--100...250100...250AF140-30-11-131SFL447001R1311AF140-30-11-131SFL447001R1311AF116-30-11-131SFL427001R131116028024...6020...60AF190-30-11-111SFL487002R1111AF190-30-11-111SFL487002R1111AF140-30-11-111SFL447001R111163...210 EF205-2101SAX531001R1101CT-ERS.21S1SVR730100R0300+BEY190-4VM140/1901SFN084813R10001SFN034403R1000--100...250100...250AF190-30-11-131SFL487002R1311AF190-30-11-131SFL487002R1311AF140-30-11-131SFL447001R131120035024...6020...60AF205-30-11-111SFL527002R1111AF205-30-11-111SFL527002R1111AF190-30-11-111SFL487002R111163...210 EF205-2101SAX531001R1101CT-ERS.21S1SVR730100R0300+BEY205-4VM191SFN085213R10001SFN030300R1000--100...250100...250AF205-30-11-131SFL527002R1311AF205-30-11-131SFL527002R1311AF190-30-11-131SFL487002R131125043024...6020...60AF265-30-11-111SFL547002R1111AF265-30-11-111SFL547002R1111AF205-30-11-111SFL527002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY265-4VM205/2651SFN085413R1000 1SFN035203R1000--100...250100...250AF265-30-11-131SFL547002R1311AF265-30-11-131SFL547002R1311AF205-30-11-131SFL527002R131131554024...6020...60AF370-30-11-111SFL607002R1111AF370-30-11-111SFL607002R1111AF265-30-11-111SFL547002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY370-4VM191SFN085813R10001SFN030300R1000--100...250100...250AF370-30-11-131SFL607002R1311AF370-30-11-131SFL607002R1311AF265-30-11-131SFL547002R131135561024...6020...60AF370-30-11-111SFL607002R1111AF370-30-11-111SFL607002R1111AF305-30-11-111SFL587002R1111115...380EF370-3801SAX611001R1101CT-ERS.21S1SVR730100R0300+BEY370-4VM191SFN085813R10001SFN030300R1000--100...250100...250AF370-30-11-131SFL607002R1311AF370-30-11-131SFL607002R1311AF305-30-11-131SFL587002R1311(1) AF09 ... AF370: ambient temperature ≤ 60 °C. (2) The setting current value is: nominal motor current x 0.58. Overload relay type given for 400 V - AC-3. For other voltage, select overload relay type according to required nominal motor current x 0.58.(3) On-delay timer without dwelling-time (e.g.: side-mounted CT-ERS.21S or front-mounted TEF4-ON) is enough to countdown the programmed starting time during "Star connection". In case of use of front-mounted TEF4-ON on-delay timer, mount on KM1 contactor AF26 ... AF96 a side-mounted CAL4-11 auxiliary contact block instead of CA4-10 auxiliary contact block.(4) AF80 can also be used, but no connection set and mechanical interlock is available for this combination.Uc = 24...240 V50/60 Hz or DC12
—Star-delta starters protected by overload relaysWith AF contactors - Open type version in kit formSwitching frequency diagramsThermal overload relayElectronic overload relay : please consult usta: motor starting timeExample: Starting time of the motor: 7 second (use 8s curve) - Duty ratio: 63 % means a permitted switching frequency of max. 15 operating cycles per hour.This corresponds to a 4 minute operating cycle (15 starts/hr) with 7 seconds acceleration, 2.5 minutes operation and 1.5 minutes rest.Intermittent periodic dutyGeneralSwitching frequency/hour, according to acceleration time and load factor. Respect of the following conditions enables utilization of the starter without excessive overheating of the connections or nuisance tripping of the thermal overload relay.0102030405060708090 100010203040506070ta = 15 sta = 12 sta = 20 sta = 10 sta = 8 sta = 5 sDuty ratio (%)Switching frequency (ops/h)1SBC101958S020112/88ABB MOTOR PROTECTION AND CONTROL12
UsNKM3:3/L2.3KM1.4A2011516LY∆01KM2(2)(2)(1)(3)KM3KM3A1A21/L13/L25/L31/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T3TESTSTOPRESETCT-ERS.21SCT-ERS.21SMA989796956/T34/T22/T1FR1KM2A1A22/T14/T26/T3W1V1U1W2V2U2W1V1U1W2V2U20II.3KM2.4A2A2A1KM1KT1A2A1KM3:5/L3UsUsNKM3:3/L2.3KM1.4A2011516LY∆01KM2(2)(2)(1)(3)KM3.3KM2.4A2A2A1KM1KT1A2A1FR19596AMRESETSTOPKM3:5/L3UsFR19596AMRESETSTOPA2KM3A122KM221A2A1KM222KM321A2KM3A122KM221A2A1KM222KM321—Star-delta starters protected by overload relaysWith AF contactors - Open type version in kit formWiring diagrams with CT-ERS.21S timerPower circuitAC or DC local control with CT-ERS.21S timerAC or DC remote control with CT-ERS.21S timerStar-delta startersNote: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection (Except for coil Uc 12-20 V DC : use VM4 with CA4). - coil Uc 12-20 V DC : A1+, A2-With VMWith VMWith VEM4With VEM41SBC101957S0201ABB MOTOR PROTECTION AND CONTROL 12/8912
UsNKM3:3/L2KM3A1A21/L13/L25/L31/L13/L25/L32/T14/T26/T3KM1A1A21/L13/L25/L32/T14/T26/T3TESTSTOPRESETMA989796956/T34/T22/T1FR1KM2A1A22/T14/T26/T3W1V1U1W2V2U2W1V1U1W2V2U2KM3:5/L3UsFR19596AMRESETSTOP.3KM1.4I.3KM2.45556KT1TEF4-ONA2A1A2A1KM1KM3KM2A2A20101(2)(2)(1)KM3KM2A2A2A1A1(1)(3)L∆Y22KM22122KM321KM3KM2A2A2A1A1(1)22KM22122KM321OIUsNKM3:3/L2KM3:5/L3UsFR19596AMRESETSTOP.3KM1.4I.3KM2.45556KT1TEF4-ONA2A1A2A1KM1KM3KM2A2A20101(2)(2)(1)(3)L∆Y—Star-delta starters protected by overload relaysWith AF contactors - Open type version in kit formWiring diagrams with TEF4-ON timerPower circuitAC or DC local control with TEF4-ON timerUc = 24...240 V 50/60 Hz or DCAC or DC remote control with TEF4-ON timerUc = 24...240 V 50/60 Hz or DCStar-delta startersNote: VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connectionWith VMWith VMWith VEM4With VEM41SBC101962S020112/90ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inches135 5.31"125 4.92"60 2.36"ø 4.2 0.17"70 2.76"5 0.20"5 0.20"2 xM4 8-32 UNC171 6.73"80 3.15"119.5 4.70"35 mm EN/IEC 607155.5 0.22"9.2 0.36"75.7 2.98"79.8 3.14"100.39"166.5 6.55"135 5.31" 100.39"35 mm EN/IEC 60715102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 1.38"60 2.36"ø 4.2 0.17"125 4.92"70 2.76"5 0.20"5 0.20"4 xM4 8-32 UNCAF26, AF30, AF38 + BEY38-4, VEM4, CA4-10+ TF42 thermal overload relayAF09, AF12, AF16+ BEY16-4, VEM4+ TF42 thermal overload relay166.5 6.55"135 5.31" 100.39"35 mm EN/IEC 60715102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 1.38"60 2.36"ø 4.2 0.17"125 4.92"70 2.76"5 0.20"5 0.20"4 xM4 8-32 UNCNote: contactor lateral distance to grounded component 2 mm 0.08" min.1SBC101963S0201 ABB MOTOR PROTECTION AND CONTROL 12/9112
—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inches155 6.10"45 1.78"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNCø 6.4 0.25"AF40, AF52, AF65+ BEY65-4, VM96-4, CA4-10, CA4-01+ TF65 thermal overload relay5.5 0.22"10 0.39"106.8 4.20"110.6 4.35"4 0.16"144 5.67"111 4.37"165 6.50"223 8.78"35 x 15 mm EN/IEC 607151SBC101964S0201 - Rev. A12/92ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesLine, Delta: AF80, AF96+ Star: AF52, AF65+ BEY96-4, VM96-4, CA4-10, CA4-01+ TF96 thermal overload relay226 8.90"195 7.68"5.5 0.22"106.8 4.20"110.9 4.37"4 0.16"149 5.87"116 4.57"35 x 15 mm EN/IEC 6071510 0.39"185 7.28"ø 6.4 0.25"60 2.36"70 2.76"110 4.33"100 3.94"M6 ¼-20 UNC45 1.77"ø 6.4 0.25"5 0.20"4.8 0.19"M6 ¼-20 UNCM4 8-32 UNC2 x2 xø 4.2 0.17"1SBC101965S0201 ABB MOTOR PROTECTION AND CONTROL 12/9312
—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesAF116, AF140, AF146+ BEY140-4, VM19+ TF140 thermal overload relay100 3.94"45 1.77"82.3 3.24"30 1.18"37 1.46"50 1.97"M5 10-24 UNC4 x60 2.36"60 2.36"12 x30 1.18"M4 8-32 UNC30 1.18"270 10.63"272 10.71"126 4.96"1SFC101170C020112/94ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by thermal overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesLine, Delta: AF190, AF205+ Star: AF116, AF140, AF146+ BEY190-4, VM140/190+ TA200 thermal overload relay3570 2.76"75 2.95"M5 10-24 UNC12 x82 3.23"37 1.46"50 1.97"165 6.50"25.51.00"1.38"351.38"301.18"100 3.94"M4 8-32 UNC4 x152 5.98"62 2.44"126 4.96"4 0.16"310 12.20"339 13.35"1SFC101171C0201 ABB MOTOR PROTECTION AND CONTROL 12/9512
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesAF26, AF30, AF38 + BEY38-4, VEM4, CA4-10+ EF19/EF45 electronic overload relayAF09, AF12, AF16+ BEY16-4, VEM4+ EF19 electronic overload relay166.5 6.55"135 5.31"100.39"35 mm EN/IEC 60715102.5 4.04"71 2.80"72.7 2.86"76.8 3.02"6.20.24"5.5 0.22"35 1.38"60 2.36"ø 4.2 0.17"125 4.92"70 2.76"5 0.20"5 0.20"4 xM4 8-32 UNCNote: contactor lateral distance to grounded component 2 mm 0.08" min.102.5 4.04"71 2.80"100.39"35 mm EN/IEC 607155.5 0.22"163 6.42"135 5.31" 76.8 3.02"73.3 2.89"17.4 0.69"135 5.31"D80 3.15"119.5 4.70"100.39"CBA35 mm EN/IEC 607155.5 0.22"EF19ABCDEF4520.4 0.80"0 0.00"76.3 3.00"82.5 3.25"79.8 3.14"165.9 6.53"183.5 7.22"86 3.39"1SBC101966S020112/96ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inches155 6.10"45 1.78"ø 4.2 0.17"110 4.33"100 3.94"5 0.20"4.6 0.18"M6 ¼-20 UNCM4 8-32 UNCø 6.4 0.25"5.5 0.22"144 5.67"111 4.37"173 6.81"251 9.88"35 x 15 mm EN/IEC 60715106.8 4.20"110.6 4.35"10 0.39"5.4 0.21"AF40, AF52, AF65+ BEY65-4, VM96-4, CA4-10, CA4-01+ EF65 electronic overload relay1SBC101967S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 12/9712
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inches185 7.28"ø 6.4 0.25"60 2.36"70 2.76"110 4.33"100 3.94"M6 ¼-20 UNC45 1.77"ø 6.4 0.25"5 0.20"4.8 0.19"M6 ¼-20 UNCM4 8-32 UNC2 x2 xø 4.2 0.17"151 5.94"251 9.88"195 7.68"149 5.87"116 4.57"10 0.39"5.4 0.21"5.5 0.22"35 x 15 mm EN/IEC 60715106.8 4.20"110.6 4.35"Line, Delta: AF80, AF96+ Star: AF52, AF65+ BEY96-4, VM96-4, CA4-10, CA4-01+ EF96 electronic overload relay1SBC101968S020112/98ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesAF116, AF140, AF146+ BEY140-4, VM19+ EF146 electronic overload relay0.85"100 3.94"43.8 1.72"30 1.18"21.537 1.46"M5 10-24 UNC60 2.36"60 2.36"14 x30 1.18"M4 8-32 UNC30 1.18"94.7 3.73"2 x270 10.63"281.5 11.08"126 4.96"1SFC101172C0201 ABB MOTOR PROTECTION AND CONTROL 12/9912
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesLine, Delta: AF190, AF205+ Star: AF116, AF140, AF146+ BEY190-4, VM140/190+ EF205 electronic overload relay3570 2.76"75 2.95"M5 10-24 UNC12 x165 6.50"1.38"351.38"20.50.81"112 4.42"100 3.94"30 1.18"M4 8-32 UNC4 x310 12.20"369 14.53"152 5.98"1SFC101173C020112/100ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesAF190, AF205+ BEY205-4, VM19+ EF205 electronic overload relay3570 2.76"M5 10-24 UNC16 x165 6.50"1.38"351.38"70 2.76"351.38"82 3.23"37 1.46"50 1.97"25.51.00"315 12.40"369 14.53"152 5.98"1SFC101174C0201 ABB MOTOR PROTECTION AND CONTROL 12/10112
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesLine, Delta: AF265, AF305, AF370+ Star: AF190, AF205+ BEY265-4, VM205/265+ EF370 electronic overload relay165 6.50"93.12 3.67"351.38"43.7543.7596.25 3.79"M5 10-24 UNC16 x112 4.41"187 7.36"291.14"1.72"351.38"1.72"417 16.42"395 15.55"180 7.09"1SFC101175C020112/102ABB MOTOR PROTECTION AND CONTROL12
—Star-delta starters protected by electronic overload relaysWith AF contactors - Open type version in kit formMain dimensions mm, inchesAF265, AF305, AF370+ BEY370-4, VM19+ EF370 electronic overload relay43.7543.7596.25 3.79"M5 10-24 UNC16 x1.72"1.72"43.7596.25 3.79"1.72"112 4.41"187 7.36"291.14"351.38"417 16.42"420 16.54"180 7.09"1SFC101176C0201 ABB MOTOR PROTECTION AND CONTROL 12/10312
— For direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 www.abb.com/productdetails/1SBL137001R1310or
13/2 Certifications and approvalsGeneral technical data13/8 Coordination with short-circuit protection devices13/10 Standards, specifications and certifying organizations13/12 Terms and technical definitions13/14 Standards and utilization categories13/16 North American standards and utilization categories13/17 Degrees of protection13/18 Climatic withstand of devices—Certifications and approvalsGeneral technical data13ABB MOTOR PROTECTION AND CONTROL 13/1
1SBC100059S0201 - Rev. D13/2ABB MOTOR PROTECTION AND CONTROL—Certifications and approvalsDesigned according to the appropriate specifications, the devices in this catalogue have been built and tested. They can be used in most countries without any further certifications.Some countries, however, require certification according to their own national standards. In other cases, the Marine for ex-ample, approvals ratifying that particular specifications have been met are necessary.The table below shows the approvals and certifications for different devices.The following documents may be obtained on request: - Certificates of conformity - Certificates of certification or approval.The use of certified devices does not exonerate the equipment supplier from complying with the legal specifications of the country concerned.Explanation of symbols: Standard design approved, the company labels bear the certification mark when this is required.CertificationsApprovals: ship classification societiesMarkGOSTBVRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACKCBVDNV-GLLRRINaABSRMRSCCSClassNKApproved inCanadaUSANorth AmericaChinaRussiaKoreaFranceGr.BritainItalyUSARussiaChina shippingJapan3-pole contactors with screw terminals4 to 7.5 KWAC operatedAS09, AS12, AS16E312527DC operatedASL09, ASL12, ASL16E3125274 to 45 kWAC / DC operatedAF09, AF12, AF16, AF26, AF30, AF38E312527AC / DC operated AF40, AF52, AF65, AF80, AF96E31252755 to 200 kWAC / DC operated (2)AF116, AF140, AF146tE36588AC / DC operated (2)AF190, AF205, AF265, AF305, AF370E36588200 to 560 kWAC / DC operatedAF400, AF460, AF580, AF750E36588AC / DC operatedAF1250E73397AC / DC operatedAF1350, AF1650E36588AC / DC operatedAF2050E73397AC / DC operatedAF2650, AF2850E73397(1)(1)(1) For 2650 only.4-pole contactors with screw terminals25 to 125 A, AC-1AC / DC operatedAF09, AF16, AF26, AF38E319322AC / DC operated AF40, AF52, AF80E312527160 to 525 A, AC-1AC / DC operatedAF116, AF140, AF190, AF205, AF265, AF305, AF370E73397(1)800 to 1000 A AC-1AC operatedEK550E36588AC operatedEK1000DC operatedEK550E36588DC operatedEK1000(1) AF116 ... AF265 only. KC only applicable to devices up to 300 A. (2) Marine approvals for AF116 ... AF370 with built-in PLC interface: only DNV is available. All AF contactors are(RCM) marked.13
1SBC100059S0201 - Rev. D ABB MOTOR PROTECTION AND CONTROL 13/3—Certifications and approvalsCertificationsApprovals: ship classification societiesMarkGOSTBVRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACKCBVDNV-GLLRRINaABSRMRSCCSClassNKApproved inCanadaUSANorth AmericaChinaRussiaKoreaFranceGr.BritainItalyUSARussiaChina shippingJapanDC switching contactorsAC operated GA75 E319322DC operated GAE75 E319322AC / DC operated GAF185 ... GAF300E73397AC / DC operated GAF460, GAF750, GAF1250, GAF1650, GAF2050E73397Capacitor switching contactorsAC operated UA16 E312527 AC operated UA26 ... UA75 E312527 AC operated UA95, UA110E36588AC operated UA16..RAE312527 AC operated UA26..RA ... UA75..RAE312527AC operated UA95..RA, UA110..RAE36588Contactor relays with screw terminalsAC operated4-pole, 8-pole - NS.. E252354DC operated4-pole, 8- pole - NSL.. E252354AC / DC operated4-pole, 8-pole - NF.. E252354All GAF and NF contactors are(RCM) marked.3-pole contactors with spring terminals4 to 7.5 KWAC operated AS09..S, AS12..S, AS16..SE312527DC operated ASL09..S, ASL12..S, ASL16..SE3125274 to 11 KWAC / DC operated AF09..S AF12..S, AF16..SE312527 AF26..SContactor relays with spring terminalsAC operated4-pole, 8-pole - NS..E252354DC operated4-pole, 8- pole - NSL..E252354AC / DC operated4-pole, 8-pole - NFS..E2523541SBC100059S020113
1SBC100059S0201 - Rev. D1 3/4ABB MOTOR PROTECTION AND CONTROLCertificationsApprovals: ship classification societiesMarkGOSTBVLRRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACBVDNV-GLLRRINaABSRMRSCCSClassNKApproved inCanadaUSANorth AmericaChinaRussiaFranceGr.BritainItalyUSARussiaChina shippingJapanAccessories for AS09 ... AS16 contactorsAuxiliary contactsCA3E252354CA3..SE252354Mechanical interlock unitVM3E312527Connecting linksBEA16-3E312527BEA16-3UE312527BER16C-3E312527BEY16C-3E312527Electronic timerTEF3E252354Surge suppressorsRT5, RC5-1, RV5E312527Accessories for AF09 ... AF2650 and EK contactors and NF contactor relaysAuxiliary contactsCA4, CC4E252354(CA4)(CA4)CAT4E252354CAL4E252354CAL19E76003CAL18E76003CAL16 E76003CE5...D0.1 E319322CE5...D2 E319322CE5...W0.1 E319322CE5...W2 E319322CEL18 E76003CA4..S, CAL4..S, CAT4..SE252354Electronic timerTEF4, TEF45E252354Mechanical / electrical interlock unitVEM4E312527Mechanical interlock unitsVM4, VM96-4E312527VM19E36588VM140/190E36588VM205/265E36588VM 750 E36588VM1650HE36588Interface relayRA4E252354 Marine approvals not needed for this accessory.—Certifications and approvals13
1SBC100059S0201 - Rev. D ABB MOTOR PROTECTION AND CONTROL 13/5CertificationsApprovals: ship classification societiesMarkGOSTBVLRRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACBVDNV-GLLRRINaABSRMRSCCSClassNKApproved inCanadaUSANorth AmericaChinaRussiaFranceGr.BritainItalyUSARussiaChina shippingJapanLatching unitWB75-A E252354WA4E312527Connecting links with manual motor startersBEA16-4, BEA26-4, BEA38-4, BEA65-4 E312527Connection sets for reversing contactorsBER16-4, BER38-4 E312527BER65-4, BER96-4 E312527BER140-4, BER205-4, BER370-4E36588BEM460-30, BEM750-30E36588Connection sets for star-delta startersBEY16-4, BEY38-4 E312527BEY65-4, BEY96-4 E312527BEY190-4, BEY205-4, BEY265-4, BEY370-4E36588BED460, BED580, BED750E36588Phase to phase connectionsBEP140-30, BEP205-30, BEP370-30E36588BEP140-40, BEP205-40, BEP370-40BES460, BES750E36588Connection bars between contactors and MCCBBEA140/XT2, BEA140/XT3E36588 BEA205/XT4E36588BEA370/T5E36588Terminal connecting strips and shorting barsLY16-4, LY38-4 E312527LY110, LY185, LY300, LY460, LY750E36588LP185, LP300, LP460, LP750E36588LH38-4 E312527LF16-4, LF38-4 E312527LG16-4 E312527LK96-4B, LK96-4F, LK96-4L E312527Additional coil terminal blocksLD38-4 E312527Additional terminal blocksLDC4 E312527Protective coversBX4, BX4-CA E252354Terminal shroudsLT65-30 ... LT96-30–LT52-40 ... LT80-40–LT140 ... LT750E36588LT140-40 ... LT370-40E73397Terminal enlargementLWE36588(1) In progress. Marine approvals not needed for this accessory.—Certifications and approvals1SBC100059S020113
1SBC100059S0201 - Rev. D13/6ABB MOTOR PROTECTION AND CONTROLCertificationsApprovals: ship classification societiesMarkGOSTATEXBVLRRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACATEXIEC ExKCBVDNV-GLLRRINaABSRMRSClassNKApproved inCanadaUSANorth AmericaChinaRussiaKoreaFranceGr.BritainItalyUSARussiaJapanTeminal extensionLXE36588Connection socketLLE36588Connection modulesLD146-30, LD146-40E36588Function markerBA4E252354Fixing clipBB4E312527Manual motor startersMS116E137861MS132E137861E345003(1)MS165E137861E345003MS132-KManual motor starters magnetic onlyMO132E137861E345003MO165E137861E345003Circuit breaker for transformer protectionMS132-TE137861MS132-KTE137864Mini contactors3-pole contactorsAC operatedB6, B7E191658DC operatedBC6, BC7, B7DE191658DC operatedB6S, B7SE1916583-pole reversing contactorsAC operatedVB6, VB7E191658DC operatedVBC6, VBC7E191658AC operatedVB6A, VB7AE191658DC operatedVBC6A, VBC7AE1916583-pole interface contactorsDC operatedBC6, BC7E1916583-pole contactor - large coil voltage rangeDC operatedTBC7(1) Valid for production date week 47, 2018. Marine approvals not needed for this accessory.—Certifications and approvals13
1SBC100059S0201 - Rev. D ABB MOTOR PROTECTION AND CONTROL 13/7CertificationsApprovals: ship classification societiesMarkGOSTATEXBVLRRinaABSRMRSAbbreviationCSAULcULusCCCGOST or EACATEXIEC ExKCBVDNV-GLLRRINaABSRMRSClassNKApproved inCanadaUSANorth AmericaChinaRussiaKoreaFranceGr.BritainItalyUSARussiaJapan4-pole contactorsAC operated B6, B7E191658DC operated BC6, B7DE1916584-pole contactor - large coil voltage rangeDC operated TBC7Contactor relaysAC operated K6E48139DC operated KC6E48139Interface contactor relaysDC operated KC6E48139DC operated K6SE48139Contactor relays - large coil voltage rangeDC operated TKC6Thermal overload relaysT16E48139TF42E48139TF65E48139(3)TF96E48139 (3)TF140DUE48139TF140DU-V1000E48139TA200DUE48139(4)TA200DU-V1000E48139(4)Electronic overload relays0.10...45 AE16DUE48139EF19E48139(1)EF45E48139(1)20...150 AEF65E48139(2)(1)(2)EF96E48139(1)EF146E48139(1)63...380 AEF205E48139(1)EF370E48139(1)150...1250 AEF460E48139(1)EF750E48139(1)EF1250 E76003Electronic compact starterHF rangeE191658 (1) IECEx is valid for product produced from week15, 2017. (2) EF65-56 has no RINa approval and ATEX certification is valid for EF65-56 produced from week 47, 2015.(3) ATEX is valid for products produced from week 26, 2015. All electronic overload relays are(RCM) marked : EF produced from week 47, 2015; E produced from week 14, 2016. (4) 2 separate certificate available: 1 for DNV and 1 for GL.—Certifications and approvals1SBC100059S020113
—Coordination with short-circuit protection devicesDefinitionThe coordination of control and protection devices In compliance with IEC 60947-4-1, EN 60947-4-1 and UL 60947-4-1 between the branch circuit protective device and the motor starter standards defines for the contactors and starters the type rating and characteristics of the short-circuit protection devices SCPD which allow selective protection against overloads and ensure protection against short circuits.Basic functionsAny starter is designed to:•start motors,•ensure continuous functioning of motors,•disconnect motors from the supply line,•guarantee protection of motors against overloads.The starter is typically made up of a switching device (contac-tor) and an overload protection device (thermal overload relay or electronic overload relay).These two devices MUST be coordinated with equipment capa-ble of providing protection against short circuit (SCPD: short circuit protective device): typically a circuit breaker with mag-netic release only or a switch fuse. These are not necessarily part of the starter.Applicable standardsIEC 60947-4-1 (EN 60947-4-1) and UL 60947-4-1 between the branch circuit protective device and the motor starter precisely defines the different points to be considered in order to carry out correct coordination.Complete coordination for a combination includes the following points:•Selectivity test between the overload relay and the short-circuit protection device SCPD.•Short-circuit condition tests:• at prospective "r" currents - These currents depend on the rated operational current of the starter (Ie AC-3) and are given by the standard (Table 13). For example: r = 1kA for Ie AC-3 < 16 A r = 3 kA for 16 A < Ie AC-3 < 63 A r = 5 kA for 63 A < Ie AC-3 < 125 A etc.•at the rated conditional short-circuit current "Iq" - This is the maximum prospective current that the combination can withstand, for example 50 kA.Types of coordinationIEC 60947-4-1 (EN 60947-4-1) UL 60947-4-1 between the branch circuit protective device and the motor starter defines two types of coordination according to the expected level of service continuity. Acceptable extreme damage for the switchgear is divided into two types.•Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate without being repaired or having parts replaced.•Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards. The risk of contacts light welding is ac-ceptable. In this case, the manufacturer must stipulate the measures to be taken with respect to maintenance of the equipment.1SBC101590S0201 - Rev. B13/8ABB MOTOR PROTECTION AND CONTROL13
—Coordination with short-circuit protection devicesA complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1) or UL 508 / UL 60947-4-1, is available on the ABB Website: see below.SelectionSimple or multiple selections all from the same screen.Results• Search results displayed at the bottom of the selection page.• Only the most appropriate solutions to your application, will be displayed at the bottom of the page. "Enable Smart Current Search" function featured for the short-circuit current where "near to" selected values also are included in the result.• Possible to print the page to a pdf file or from your printer.• "Clear selection" function to deselect all selected.Short-circuit protection devices• Air circuit breakers• Fuses "gG" or "aM"• Miniature circuit breaker• Moulded case circuit breaker • Manual motor starter Starter type• Direct-on-line normal start• Direct-on-line heavy duty• Star-delta normal start• Soft starter normal startOverload relay• TOL : thermal overload relay• EOL : electronic overload relay• UMC : Universal motor controllerCoordination• IEC type 1 or type 2• UL type A to Type F1SBC101591S0201 - Rev. B ABB MOTOR PROTECTION AND CONTROL 13/913AccessTo find the coordination tables for motor protection, please see:http://applications.it.abb.com/SOC/Page/Selection.aspx
1SBC101630S0201 - Rev. B13/10ABB MOTOR PROTECTION AND CONTROL—Standards, specifications and certifying organizationsDefinitionsABB low voltage devices are developed and manufactured in ac-cordance with the applicable regulations as stated in the inter-national IEC standards, the European EN standards and the na-tional ones such as NF, DIN, GB and BS. For devices installed in ships, an approval issued by independent classification societ-ies is demanded by the maritime insurance companies.CB schemeCertification Body certificates (CB certificates) are available to prove the complete conformity to standardsThe IEC CB (Certification Body) scheme is multilateral agree-ment between the National Certification Bodies to allow inter-national certification of electrical and electronic products so that a single certification allows worldwide market access. The CB Scheme was established by the International Electro-technical Committee for conformity testing to standards for electrical equipment (IECEE).Certified productsIn some cases, products are validated and tested according to a standard by a certification body and the manufacturer is regu-larly visited by this body in order to check the respect of the de-sign and the materials used. This process creates a certified product. This is the case of UL (Underwriters Laboratories) and CSA (Canadian Standard Association) for instance (see below).SpecificationsInternational SpecificationsThe International Electrotechnical Commission, IEC, which is part of the International Standards Organization, ISO, publishes IEC publications which act as a basis for the world market.European Specifications and National SpecificationsThe European committee for electrotechnical standardization (CENELEC), which groups together European countries, pub-lishes EN standards.These European standards may differ very little from IEC inter-national standards and have similar numbering.The same applies for national standards which use, without ex-ception, the same numbering and reproduce the texts of these unified standards in their entirety. Contradicting national stan-dards are withdrawn.European DirectivesThe guarantee of the free movement of goods within the Euro-pean Community means that any regulatory differences be-tween member states have been eliminated. The European di-rectives set up common rules that are included in the legislation of each state while contradictory regulations are cancelled.Three directives are essential:•Low Voltage Directive 2006/95/EC (until April 2016, 19th) and2014/35/EC (from April 2016, 20th) concerns electrical equip-ment from 0 to 1000 V AC and from 0 to 1500 V DC.This specifies that compliance with the requirements that it sets out is acquired if the equipment conforms to the standards harmonized on an European level. EN 60947-1 and EN 60947-4-1 for contactors.•Machinery Directive 2006/42/EC for safety specifications of machines and equipment on complete machines.•Electromagnetic Compatibility Directive 2004/108/EC (until April 2016, 19th) and 2014/30/EC (from April 2016, 20th) which concerns all devices able to create electromagnetic distur-bance.CE Marking:CE marking indicates that the marked equipment conforms to the relevant EU directive.CE marking is part of an administrative procedure and guaran-tees free movement of the product within the European Com-munity.Standards in Canada and the USACanadian and American specifications are more or less equiva-lent but differ greatly from IEC standards.UL Underwriters Laboratories USA CSA Canadian Standard Association Canada UL (USA) specifications make the following distinction between devices:Listed ProductA product that has been produced under UL's listing and follow-up service program in accordance with the terms of UL's service agreement and that bears the UL listing mark as the manufacturer's declaration that the product complies with UL's requirements. Recognized ComponentA part or subassembly covered under UL's recognition service and intended for factory installation in listed (or other) products. Recognized components are incom-plete in certain construction features or restricted in performance capabilities and not intended for separate installation in the field, rather they are intended for use as components of incomplete equipment submitted for investigation by UL. Final acceptance of the component in the complete equipment is dependent upon its instal-lation and use in accordance with all applicable use con-ditions and ratings noted in the component report is-sued by UL, in the guide information and in the individual client's Recognized Component information page. The combined UL signs for the USA and Canada are rec-ognized by the authorities of both countries.Compulsory China Certification (CCC): The CCC mark is a com-pulsory certification mark in the field of safety for products sold on the Chinese market.GOST / EAC: Russia (please consult your local ABB sales office) C-Tick: The C-Tick mark certifies compliance with the Australian EMC requirements. The mark is also recognized in New ZealandANCE: MexicoMarine ApprovalsThe following specifications must be respected when these de-vices are used on ships:BV Bureau Veritas FranceDNV Det Norske Veritas NorwayGL Germanischer LIoyd Germany13
1SBC101630S0201 - Rev. BABB MOTOR PROTECTION AND CONTROL 13/11—Standards, specifications and certifying organizationsLRS LIoyd's Register of Shipping Great BritainABS America Bureau of ShippingRMRS Russian Maritime Register of Shipping RMRSRRR Russian River RegisterMRS Maritime Register of Shipping RussiaPRS Polski Rejestr Statkow PolandRINA Registro Italiano Navale ItalySpecifications (cont.)International StandardsIEC 60947-1 Low-voltage switchgear and controlgear – Part 1: General rulesIEC 60947-4-1 Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters – Section 1: Electromechanical contactors and motor startersIEC 60947- 5-1 Low-voltage switchgear and controlgear – Part 5: Control circuit devices and switching elements – Section 1: Elec-tromechanical control circuit devicesIEC 60947-5-4 Low-voltage switchgear and controlgear – Part 5-4: Control circuit devices and switching elements. Method of assessing the performance of low-energy contacts. Special testsIEC 60947- 6-1 Low-voltage switchgear and controlgear – Part 6: Multiple function equipment – Section 1: Automatic transfer switching equipmentIEC 60204-1 Electrical equipment of industrial machines – Part 1: General requirementsIEC 60715 Dimensions of low-voltage switchgear and control-gear. Standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installationsEuropean StandardsEN 50 005 Low-voltage switchgear and controlgear for indus-trial use – Terminal marking and distinctive number: General rules(Annex L of IEC 60947-1).EN 50 011 Low-voltage switchgear and controlgear for industrial use – Terminal marking, distinctive number and distinctive let-ter for particular contactor relays (Annex M of IEC 60947-5-1)EN 60947-1 Low-voltage switchgear and controlgear – Part 1: General rules.EN 60947-4-1 Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters – Section 1: Electromechanical contactors and motor starters.EN 60947-5-1 Low-voltage switchgear and controlgear – Part 5: Control circuit devices and switching elements – Section 1: Elec-tromechanical control circuit devices.EN 60947-5-4 Low-voltage switchgear and controlgear – Part 5-4: Control circuit devices and switching elements. Method of assessing the performance of low-energy contacts. Special tests.EN 60947- 6-1 Low-voltage switchgear and controlgear – Part 6: Multiple function equipment – Section 1: Automatic transfer switching equipment.EN 60204-1 Electrical equipment of industrial machines – Part 1: General requirements.EN 60 715 Dimensions of low-voltage switchgear and control-gear. Standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installations.National StandardsEuropean countries national standards reproduce the corre-sponding EN... standards. Codification is built by addition of a prefix to EN numbering.For instance: •France NF EN...•Germany DIN EN...•Great Britain BS EN...•Italy CEI EN...•Sweden SS EN...13
1SBC101625S0201 - Rev. C13/12ABB MOTOR PROTECTION AND CONTROL—Terms and technical definitionsCircuits•auxiliary circuit: All the conductive parts of a contactor de-signed to be inserted in a different circuit from the main cir-cuit and the contactor control circuits.• control circuit: All the conductive parts of a contactor (other than the main circuit and the auxiliary circuit) used to control the contactor's closing operation or opening operation or both.•main circuit: All the conductive parts of a contactor designed to be inserted in the circuit that it controls.Thermal overload relay tripping classesIEC 60947-4-1 defines tripping classes 10 A, 10, 20 and 30. Types 10 A, 10, etc. correspond to the maximum tripping time for a making current at 7.2 times the setting current.Furthermore, for each class the standard specifies the tripping time for 1.5 times the setting current and sets the non tripping condition at 1.05 times the setting current.All these data are summarized in the table below.Extract from IEC 60947-4-1:Tripping class10 A102030Max. tripping time for 1.5 timesthe setting current (warm state)s120240480720Tripping time for 7.2 timesthe setting current (cold state)s2 - 10 4 - 10 6 - 20 9 - 30For 1.05 times the setting currentNo trippingElectromagnetic compatibilityAF... contactors comply with IEC 60947-1, 60947-4-1 and EN 60947-1, 60947-4-1 standards.Definitions:Environment A: "Mainly relates to low-voltage non public or in-dustrial networks/locations/installations (EN 50082-2 article 4) including highly disturbing sources".Environment B: "Mainly relates to low-voltage public networks (EN 50082-1 article 5) such as residential, commercial and light industrial locations/installations. Highly disturbing sources such as arc welders are not covered by this environment".Notice for AF09...AF2650 contactors:•AF09 ... AF38 contactors and NF contactor relays (producedsince week 08-2013), AF40 ... AF96 contactors have been designed for environment B.•AF09 ... AF38-..-..-12 contactors and NF..E-12 contactor relays (48...130 V 50/60 Hz-DC), AF116 ... AF2650 contactors: these products have been designed for environment A.Use of this product in environment B may cause unwanted electromagnetic disturbances in which case the user may be required to take adequate mitigation measures.Note: for 48...130 V 50/60 Hz-DC in environment B, AF09Z ... AF38Z-..-..-22 contactor or NFZ..E-22 contactor relays can be selected.Definitions according to SEMI F47-0706SEMI F47-0706 defines the voltage sag immunity required for semiconductor processing, metrology and automated test equipment, and on subsystems and components which are used in the construction of semiconductor processing equipment in-cluding but not limited to:•Power supplies•Generators•Robots and factory interface•Chillers, pumps, blowers•AC operated contactors and contactor relays...voltage sag: an rms reduction in the AC voltage, at the power frequency, for durations from a half cycle to a few seconds.The IEC terminology for this phenomenon is voltage dip.voltage sag immunity: the ability of equipment to withstand momentary electrical power interruptions or sags.Coordination of protections against short circuitThe goal here is to protect electromechanical starters and soft-starters.Any starter is designed to:•start motors,•ensure continuous functioning of motors,•disconnect motors from the supply line,•guarantee protection of motors against overloads.The starter is typically made up of a switching device (contac-tor) and an overload protection device (thermal overload relay or electronic overload relay). These two devices MUST be coordi-nated with equipment capable of providing protection against short circuit (SCPD: short circuit protective device): typically a circuit breaker with magnetic release only or a switch fuse. These are not necessarily part of the starter.The characteristics of the starter must comply with the interna-tional standard IEC 60947-4-1 which defines the above items as follows:contactor: a mechanical switching device having only one posi-tion of rest, operated otherwise than by hand, capable of mak-ing, carrying and breaking currents under normal circuit condi-tions including overload conditions.overload release: overload relay or release which operates in the case of overload and also in case of loss of phase.circuit-breaker: defined by IEC 60947-2 as a mechanical switch-ing device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions.IEC publication 60947-4-1 defines coordination types "1" and "2":•Type "1" coordination requires that, in the event of a short-cir-cuit, the contactor or starter does not endanger persons or in-stallations and will not then be able to operate without being repaired or parts being replaced. •Type "2" coordination requires that, in short-circuit condi-tions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards. The risk of contacts being light welded is acceptable. In this case, the manufacturer must stipulate the measures to be taken with respect to maintenance of the equipment. Rated operational current Ie.Current rated by the manufacturer. It is mainly based on the rated operational voltage Ue, the rated frequency, the utilization category, the rated duty and the type of protective enclosure, if necessar y.Conventional free air thermal current IthCurrent that the contactor can withstand in free air for a duty time of 8 hours without the temperature rise of its various parts exceeding the maximum values given by the standard.Operating cycle or cycleIncludes one making operation and one breaking operation.13
1SBC101625S0201 - Rev. C ABB MOTOR PROTECTION AND CONTROL 13/13—Terms and technical definitionsCycle timeThis is the sum of the current flow time and the no-current time for given cycle.Electrical durabilityNumber of on-load operating cycles that the contactor is able to carry out. It depends on the operational current, the operational voltage and the utilization category.Mechanical durabilityNumber of no-current operating cycles that a contactor is able to carry out.Assessed failure rateDefined according to IEC 60947-5-4. This rate is given in stan-dard industrial environments for the contactor relays and for the built-in auxiliary contact of contactors.Load factorRatio of the on-load operating time to the total cycle time x 100.Switching frequency Number of switching cycles per hour.PluggingStopping or fast reversal in rotation direction of a motor by two supply leads being interchanged while the motor is running.InchingEnergization of a motor's circuit repeatedly or for short periods with the aim of obtaining small movements of the driven mecha-nism. Coil operating limitsExpressed in multiples of the nominal control circuit voltage Uc for the upper and lower limits.Mounting positionComply with the manufacturer's instructions. Restrictions are to be taken into account for certain mounting positions.Rated breaking or making capacityRoot mean square (r.m.s.) value of the current that the contactor is able to break or make at a given voltage according to the con-ditions specified by standards and for a given utilization cate-gory.Intermittent dutyDuty during which the contactor is successively closed or open for periods which are too short to enable the contactor to achieve thermal balance.Ambient temperatureAir temperature close to the contactor.Time• Time constant: Ratio of the inductance to the resistance (L/R = mH/Ω = ms).• Short-time withstand current: Current that the contactor is able to withstand in closed position for a short time interval and in specified conditions.• Closing time: Time interval between the coil energization and the instant the contacts touch on all the poles.• Opening time: Time interval between the coil de-energization and the instant the contacts separate on all the poles.Rated control voltage UcControl voltage value for which the control circuit is sized.Rated operational voltage UeVoltage to which the contactor's utilization characteristics refer. In three-phase it is the phase-to-phase voltage.Rated insulation voltage UiReference voltage for dielectric tests and creepage distances.Rated impulse withstand voltage UimpPeak value of an impulse voltage, having a specified form and polarity, which does not cause breakdown in specific test condi-tions. Shock withstandRequirement for vehicles, crane drives, installations on board ships and plug-in equipment. For the acceptable "g" values, the contacts must not change position and the thermal overload re-lays must not trip.Resistance to vibrationsRequirements for vehicles, boats and other means of transport. For the specified vibration amplitude and frequency values the device must remain able to operate.Mirror contacts Definitions of mirror contact acc. to IEC 60947-4-1, Annex F 2.1. Normally closed auxiliary contact (N.C.) which cannot be in the closed position simultaneously with the normally open (N.O.) main contact.Mechanically linked contact Definitions of mechanically linked elements acc. to IEC 60947-5-1, Annex L. Combination of "n" Make auxiliary contact element(s) and "m" Break auxiliary contact element(s) are designed in such a way that they cannot be in the closed position simultaneously. One control circuit device may have more than one group of me-chanically linked contact elements.13
1SBC101626S0201 - Rev. A13/14ABB MOTOR PROTECTION AND CONTROL—Standards and utilization categoriesUtilization categories:A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated.Utilization categories for contactors according to IEC 60947-4-1:Alternating current:AC-1Non-inductive or slightly inductive loads, resistance furnaces.AC-2Slip-ring motors: starting, switching off.AC-3Cage motors: starting, switching off running motors.AC-4Cage motors: starting, plugging, inching.AC-5aDischarge lamp switching.AC-5bIncandescent lamp switching.AC-6aTransformer switching.AC-6bCapacitor bank switching.AC-8aHermetic refrigeration compressor motor control with manual resetting of overload releases.AC-8bHermetic refrigeration compressor motor control with automatic resetting of overload releases.Direct current:DC-1Non inductive or slightly inductive loads, resistance furnaces.DC-3Shunt motors: starting, plugging, inching, dynamic breaking of DC motors.DC-5Series motors: starting, plugging, inching, dynamic breaking of DC motors.DC-6Incandescent lamp switching.Utilization categories for contactor relays according to IEC 60947-5-1:Alternating current: AC-12Control of resistive loads and static loads with opto-coupler isolation.AC-13Control of static loads with transformer isolation.AC-14Control of weak electromagnetic loads (≤ 72 VA).AC-15Control of electromagnetic loads (> 72 VA).Direct current:DC-12Control of resistive loads and static loads with opto-coupler isolation.DC-13Control of DC electromagnets.DC-14Control of DC electromagnets having economy resistors.In fact some applications, and the specific criteria characterizing the various loads controlled by contactors, may modify the utilization characteristics of the contactors. The main applications concerned are:Capacitor bank switchingAccount must be taken of high peaks when the current is made and of harmonic currents during continuous duty. For this ap-plication, IEC publication 60947-4-1 stipulates utilization category AC-6b. The operational currents or powers acceptable for the contactors are determined by our electrical tests; IEC publication 60947-4-1 gives the calculating formula for determin-ing the operational current (Table 9). Transformer switchingAccount must be taken of the peaks due to magnetization phenomena when the current is made.For this application, IEC publication 60947-4-1 stipulates utilization category AC-6a. The operational currents or powers ac-ceptable for the contactors are determined using the values obtained for AC-3 or AC-4 category tests and the calculating for-mula given in IEC 60947-4-1 (Table 9).Lighting circuit switchingThe current peaks occurring on energization of the circuit and the power factor depend on the type of lamps, the connection mode and whether or not there is compensation.For this application, IEC publication 60947-4-1 stipulates two standard utilization categories:AC-5a for discharge lamp switching.AC-5b for incandescent lamp switching.Slip-ring motor switchingThe contactors used for short-circuiting rotor resistors can be used for rotor voltages up to 2 times the rated operational voltage.The conditions of use of rotor contactors depend on the connection mode of the main poles. IEC 60947-4-1 stipulates AC-2 utilization category for startor contactor.13
1SBC101626S0201 - Rev. A ABB MOTOR PROTECTION AND CONTROL 13/15—Standards and utilization categoriesUtilization categories (cont.)DC power circuit switchingArc suppression is more difficult in direct current than in alternating current. Higher the time constant and voltage, heavier the breaking conditions: consequently several poles have to be connected in series.AC high current circuit switchingPossibility of increasing performances by connecting poles in parallel.Circuit switching during temporary and intermittent dutyIn these cases higher operational currents are acceptable.Influence of the length of the conductors used in the contactor control circuitAccording to the operational voltages, the cross-sectional areas, the coil consumption and the control layout, difficulties due to line resistances and capacitances may appear during contactor closing and opening orders.Making and breaking conditions for utilization categoriesUtilization categoryDurability test conditionsOccasional operationMaking and breaking capacities - 50 operating cyclesMaking conditionsBreaking conditionsMaking conditionsBreaking conditionsI/IeU/UeCos. φorL/R (ms)I/IeU/UeCos. φorL/R (ms)Ic/IeU r/ U eCos. φorL/R (ms)Ic/IeU r/ U eCos. φorL/R (ms)Contactors for AC circuit switchingAC-1110.95110.951.51.050.81.51.050.8AC-22.510.652.510.6541.050.6541.050.65AC-3 Ie < 17 A610.6510.170.65101.050.4581.050.4517 < Ie < 100 A610.3510.170.35101.050.4581.050.45Ie > 100 A610.3510.170.35101.050.3581.050.35AC-4Ie < 17 A610.65610.65121.050.45101.050.4517 < Ie < 100 A610.35610.35121.050.45101.050.45Ie > 100 A610.35610.35121.050.35101.050.35Contactors for DC circuit switchingDC-11111111.51.0511.51.051DC-32.5122.51241.052.541.052.5DC-52.517.52.517.541.051541.0515Contactor relays for AC circuit switchingAC-14(≤ 72 VA)–– ––– –61.10.761.10.7AC-15(> 72 VA)1010.7110.4101.10.3101.10.3Contactor relays for DC circuit switchingUtilization categoryStandard operationOccasional operationMaking and breaking capacities - 50 operating cyclesMaking conditionsBreaking conditionsMaking conditionsBreaking conditionsI/IeU/UeT0.95I/IeU/UeT0.95Ic/IeU r/ U eT0.95Ic/IeU r/ U eT0.95DC-13116 P(1)116 P(1)1.11.16 P(1)1.11.16 P(1)DC-14––––––101.115 ms101.115 ms(1) The value "6 x P" is the result of an empirical relation which is estimated to represent most DC magnetic loads up to the highest limit of P = 50 W (6 x P = 300 ms). It is accepted that loads having drawn energy above 50 W are made up of weaker loads in parallel. As a consequence, the 300 ms value must form the highest limit whatever the value of the power drawn.Key:U (I) = applied voltage (current)Ur = recovery voltageL/R = test circuit time constantUe (Ie) = rated operational voltage (current)Ic = making and breaking current expressed in DC or in AC like the r.m.s. value of the symmetrical componentsT0.95 = time required to reach 95 % of the current in steady-state conditions, expressed in milliseconds13
1SBC100110S020113/16ABB MOTOR PROTECTION AND CONTROLDepending on the utilization category or intended rating for a contactor, North American standards require two main tests: an en-durance test to simulate conventional device making and breaking capacity over its lifetime, and an overload test to simulate peri-odic conditions demanding higher making and breaking capacity than is conventional for the application. The test setups differ in regards to current, power factor, and number of electrical operating cycles. The tables below provide a comparison of the types of load testing for contactors rated up to 100 A.AC load testing for contactors rated up to 100 AHarmonized testRating designationEndurance (conventional) testOverload (conditional) testRequired load markingIECULCSAMultiple of currentPower factorNumber of cyclesMultiple of currentPower factorNumber of cyclesGeneral use, non-inductive or slighting inductive loads, resistance furnaces and heatersAC-1: general use10.86 0001.50.850–AC resistance116 0001.5150"Resistive"AC resistance air heating11100 0001.5150"Resistance"AC electrical heating control11250 0001.5150–Motor loadsAC-2: slip-ring motors20.656 00040.6550–AC-3: squirrel cage motors20.456 00010 for make 8 for make break0.4550 make + 50 make break–AC motor (across-the-line switching)20.40 – 0.501 000LRA (~6) 0.40 – 0.5050–Elevator control, AC motor20.50500 000n/an/an/a"Elevator duty"AC-4: plugging, inching, jogging60.456 00012 for make 10 for make break0.4550 make + 50 make break–Lamps and lighting loadsAC-5a: electric discharge lamps20.456 00030.4550"Ballast"AC-5b: incandescent lamps1Lamp6 0001.5Lamp50"Tungsten"Transformers and capacitorsAC-6a: transformersThe manufacturer shall verify the AC-6a rating by testing with a transformer, or may derive the rating from the values for AC-3.AC-6b: capacitorsCapacitive ratings may be derived by capacitor switching tests or assigned on the basis of established practice and experience.Capacitive switching (kVar)1Capacitor6 0001.5Capacitor50–Hermetic refrigerant compressor motorsAC-8a: hermetic refrigerant compressor10.830 00060.4550"Hermetic refrigeration compressor"AC-8b: hermetic refrigerant compressor (recycle rating)60.456 00060.4550–Note: the information above is an overview of UL 60947-4-1 tables 1, 7, 10, 5.4.1DV.1.1, 8.2.4.1DV.1.1, and 8.2.4.2DV.1.1 and is intended for comparison purposes only.DC load testing for contactors rated up to 100 AHarmonized testRating designationEndurance testOverload testRequired load markingIECULCSAMultiple of currentL/R msNumber of cyclesMultiple of currentL/R msNumber of cyclesGeneral use, non-inductive or slighting inductive loads, resistance furnaces and heatersDC-1: general use116 0001.5150–DC resistance116 0001.5150"Resistive"DC resistance air heating11100 0001.5150"Resistance"Motor loadsDC-3: shunt motors2.526 00042.550–DC motor (across-the-line switching)2n/a1 00010 n/a50–Elevator control, DC motor2n/a500 000Not applicable"Elevator duty"DC-5: series motors2.57.56 00041550–Lamps and lighting loadsDC-6: incandescent lamps1Lamp6 0001.5Lamp50"Tungsten"Note: the information above is an overview of UL 60947-4-1 tables 1, 7, 10, 5.4.1DV.1.1, 8.2.4.1DV.1.1, and 8.2.4.2DV.1.1 and is intended for comparison purposes only.—North American standards and utilization categories13
1SBC101627S0201 ABB MOTOR PROTECTION AND CONTROL 13/17—Degrees of protectionGeneralIn an installation, the degree of protection required for electrical equipment depends on the environmental characteristics. The degree of protection, ensured by the enclosure of equipment or by the cubicle containing the equipment is expressed by the IP code which gives the level of protection against access to hazardous parts, the ingress of foreign bodies and/or the in-gress of water, in compliance with IEC 60529, IEC 60947-1.Besides the IP symbol, the complete code has two figures followed (optionally) by two additional letters. A short description of the elements used in IP coding is given below.IP... codeFigures or lettersSpecifications for installation protection Protection of persons First figureAgainst ingress of foreign bodiesAgainst access to hazardous parts with:0No protectionNo protection1Diameter > 50 mm Back of hand2Diameter > 12.5 mmFinger3Diameter > 2.5 mm Tool4Diameter > 1 mm Wire5Limited protection against dustWire6Total protection against dustWireSecond figureAgainst entrance of water having a harmful effect0No protection1Vertical dripping2Dripping at a vertical angle of < 15°3Rain at a vertical angle of < 60° 4Splashing5Low pressure water jet6Powerful water jets7Temporary immersion8Permanent immersionAdditional letter (optional) for use with:Against ingress of foreign bodies Against access to hazardous parts with:First figure 0AStopped by a barrier with a 50 mm Ø sphereBack of handFirst figure 0 or 1BEntrance of test finger limited to 80 mmFingerFirst figure 1 or 2CWire with 2.5 mm Ø and length of 100 mmToolFirst figure 2 or 3DWire with 1 mm Ø and length of 100 mmWireAdditional letter (optional)Specific additional informationHHigh voltage apparatus –MMoving parts which are moving during water testSMoving parts which are stationary during water testWSpecified atmospheric conditionsNote: The type of enclosure or cubicle in which the equipment must be installed prevails with respect to the degree of protection.13
1SBC101628S020113/18ABB MOTOR PROTECTION AND CONTROL—Climatic withstand of devicesThe life time of devices are mainly influenced by series of climatic factors which cause their corrosion.In practice, besides climatic conditions, there are other factors which may damage equipment such as fungi, insects (termites), dust, work site dirt and aggressive environment (salty or sulphurous atmosphere, etc.) which can often only be identified at the place of installation.Climatic stress, definitions and test conditions are dealt with in national publications such as the DIN 50 series and UTE 63-100 publication which are attached to international publications such as IEC 60068. The test conditions are:DescriptionSymbolizationTime of one cycleCycle phase timeTemperature in test chamberRelative humidityHumidityandvariabletemperatureIEC 60068-2-30Te st D b24 hours12 hours including rise in temperature40 °C95 %12 hours including cooling (open device)25 °C95 %ABB contactors have been used for many years in the most countries, with hot and humid climates for example: Brazil, Indonesia, India or on ships. Experience has shown that ABB devices can be used in most countries throughout the world. The climate of the country in which the apparatus is installed is not the determining choice factor.Account must be taken of:•the immediate environment of the devices (sheltered, ventilated, temperature),•the aggressivity of the immediate atmosphere at the place of installation,• the length and frequency of non operating periods.In the case of frequent condensation (i.e. the formation of condensation caused by rapid changes in temperature), heating resistors must be installed in cubicles (100 to 250 W per m³ of enclosure).The table below gives the cases where heating is necessary.EnvironmentOperating conditionsClimateInternal heating of enclosureInsidepremisesNo running waterno condensationContinuous or notAll climatesWithoutWith running waterContinuousAll climatesWithoutFrequent or long stopsTemperateWithoutTropic alWithOutside, shelteredNo running waterno condensationContinuous or notTemperateWithoutTropic alWithOutside orby the seasideWith running waterContinuousAll climatesWithoutFrequent or long stopsTemperateWithoutTropic alWithThe entrance of dust, insects, dirt, etc. in devices may be prevented if the appropriate degree of protection according to IEC 60529 is chosen (See "Degree of protection" table).13
—Notes13 ABB MOTOR PROTECTION AND CONTROL 13/19
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/1ABB MOTOR PROTECTION AND CONTROL1SAJ231000R0001 DNP31.0 11/111SAJ242000R0001 PDP32.0 11/111SAJ243000R0001 PDR31.0 11/111SAJ251000R0001 MRP31.0 11/111SAJ260000R0100 MTQ22-FBP.0 11/131SAJ261000R0100 PNQ22-FBP.0 11/131SAJ262000R0100 EIU32.0 11/131SAJ510002R0002 UMCPAN-CAB.300 11/91SAJ510003R0002 UMCPAN-CAB.070 11/91SAJ510004R0002 UMCPAN-CAB.150 11/91SAJ510005R0001 UMC100-PAN CAP 11/91SAJ530000R0100 UMC100.3 DC 11/81SAJ530000R0200 UMC100.3 DC EX 11/81SAJ530000R0210 UMC100.3 DC EX Coated 11/81SAJ530000R1100 UMC100.3 UC 11/81SAJ530000R1200 UMC100.3 UC EX 11/81SAJ530000R1210 UMC100.3 UC EX Coated 11/81SAJ590000R0103 UMC100-PAN 11/91SAJ611000R0101DX111-FBP.011/101SAJ613000R0101 AI111.0 11/101SAJ622000R0101 DX122-FBP.0 11/101SAJ650000R0100 VI150-FBP.0 11/101SAJ655000R0100 VI155-FBP.0 11/101SAJ691000R0001 UMCIO-CAB.030 11/101SAJ692000R0001 IOIO-CAB.030 11/101SAJ924012R0006 PBDTM-FBP.0 11/151SAJ924013R0001 UTP22-FBP.0 11/151SAJ929160R0001 UMCTB-FBP.0 11/101SAJ929160R0002 UMCTB.1 11/101SAJ929180R0015 CDP18.150 11/121SAJ929200R0001 ETHTB-FBP.4 11/141SAJ929200R0002 ETHTB-FBP.50 11/141SAJ929200R0020 CEM11-FBP.20 11/161SAJ929200R0035 CEM11-FBP.35 11/161SAJ929200R0060 CEM11-FBP.60 11/161SAJ929200R0120 CEM11-FBP.120 11/161SAJ929230R0015 CDP23.150 11/141SAJ929230R0030 CDP23.300 11/141SAJ929240R0015 CDP24.150 11/121SAJ929400R0002 UTF21-FBP.0 11/151SAJ929500R0185 CT4L185R/4 11/161SAJ929500R0310 CT4L310R/4 11/161SAJ929501R0500 CT5L500R/4 11/161SAJ929501R0850 CT5L850R/4 11/161SAJ929600R0001 SMK3.0 11/121SAJ929610R0001 SMK3-X2.10 11/121SAJ929620R0001 SMK3-X1.10 11/121SAM101923R0002 MSMN 2/451SAM101923R0012 MSMNO 2/451SAM201901R1001 HKF1-11 2/351SAM201901R1002 HKF1-20 2/351SAM201901R1003 HKF1-10 2/351SAM201901R1004 HKF1-01 2/351SAM201901R1201 HKF1-11K 2/371SAM201901R1202 HKF1-20K 2/371SAM201902R1001 HK1-11 2/351SAM201902R1002 HK1-20 2/351SAM201902R1003 HK1-02 2/351SAM201902R1004 HK1-20L 2/351SAM201902R1201 HK1-11K 2/371SAM201902R1202 HK1-20K 2/371SAM201902R1203 HK1-02K 2/371SAM201902R1204 HK1-20LK 2/371SAM201903R1001 SK1-11 2/351SAM201903R1002 SK1-20 2/351SAM201903R1003 SK1-02 2/351SAM201903R1201 SK1-11K 2/371SAM201903R1202 SK1-20K 2/371SAM201903R1203 SK1-02K 2/371SAM201904R1001 UA1-24 2/361SAM201904R1002 UA1-48 2/361SAM201904R1003 UA1-60 2/361SAM201904R1004 UA1-110 2/361SAM201904R1005 UA1-230 2/361SAM201904R1006 UA1-400 2/361SAM201904R1007 UA1-415 2/361SAM201904R1008 UA1-208 2/361SAM201904R1009 UA1-575 2/361SAM201904R1010 UA1-20 2/361SAM201906R1102 PS1-2-0-65 2/411SAM201906R1103 PS1-3-0-65 2/411SAM201906R1104 PS1-4-0-65 2/411SAM201906R1105 PS1-5-0-65 2/411SAM201906R1112 PS1-2-1-65 2/411SAM201906R1113 PS1-3-1-65 2/411SAM201906R1114 PS1-4-1-65 2/411SAM201906R1115 PS1-5-1-65 2/411SAM201906R1122 PS1-2-2-65 2/411SAM201906R1123 PS1-3-2-65 2/411SAM201906R1124 PS1-4-2-65 2/411SAM201906R1125 PS1-5-2-65 2/411SAM201907R1101 S1-M1-25 2/411SAM201907R1102 S1-M2-25 2/411SAM201907R1103 S1-M3-25 2/411SAM201908R1001 BS1-3 2/411SAM201909R1001 FS116 2/411SAM201909R1021 MSAH1 2/451SAM201910R1001 AA1-24 2/361SAM201910R1002 AA1-110 2/361SAM201910R1003 AA1-230 2/361SAM201910R1004 AA1-400 2/361SAM201911R1010 IB132-G 2/441SAM201911R1011IB132-Y2/441SAM201912R1010 DMS132-G 2/441SAM201912R1011DMS132-Y2/441SAM201913R1103 S1-M3-35 2/411SAM201914R1001 PB1-1-32 2/411SAM201914R1002 S1-PB1-25 2/411SAM201916R1103 PS1-3-0-100 2/411SAM201916R1104 PS1-4-0-100 2/411SAM201916R1105 PS1-5-0-100 2/411SAM201916R1113PS1-3-1-1002/411SAM201916R1114PS1-4-1-1002/411SAM201916R1115PS1-5-1-1002/411SAM201916R1123 PS1-3-2-100 2/411SAM201920R1000 MSH-AR 2/451SAM201920R1001 MSHD-LB 2/451SAM201920R1002 MSHD-LY 2/451SAM201920R1011 MSHD-LTB 2/451SAM201920R1012 MSHD-LTY 2/451SAM250000R1001 MS116-0.16 2/101SAM250000R1002 MS116-0.25 2/101SAM250000R1003 MS116-0.4 2/101SAM250000R1004 MS116-0.63 2/101SAM250000R1005 MS116-1.0 2/101SAM250000R1006 MS116-1.6 2/101SAM250000R1007 MS116-2.5 2/101SAM250000R1008 MS116-4.0 2/101SAM250000R1009 MS116-6.3 2/101SAM250000R1010 MS116-10 2/101SAM250000R1011 MS116-16 2/101SAM250000R1012 MS116-12 2/101SAM250000R1013 MS116-20 2/101SAM250000R1014 MS116-25 2/101SAM250000R1015 MS116-32 2/101SAM250005R1001 MS116-0.16-HKF1-11 2/101SAM250005R1002 MS116-0.25-HKF1-11 2/101SAM250005R1003 MS116-0.4-HKF1-11 2/101SAM250005R1004 MS116-0.63-HKF1-11 2/101SAM250005R1005 MS116-1.0-HKF1-11 2/101SAM250005R1006 MS116-1.6-HKF1-11 2/101SAM250005R1007 MS116-2.5-HKF1-11 2/101SAM250005R1008 MS116-4.0-HKF1-11 2/101SAM250005R1009 MS116-6.3-HKF1-11 2/101SAM250005R1010 MS116-10.0-HKF1-11 2/101SAM250005R1011 MS116-16.0-HKF1-11 2/101SAM250005R1012 MS116-12.0-HKF1-11 2/101SAM250005R1013 MS116-20-HKF1-11 2/101SAM250005R1014 MS116-25-HKF1-11 2/101SAM250005R1015 MS116-32-HKF1-11 2/101SAM301901R1001 CK1-11 2/351SAM301901R1002 CK1-20 2/351SAM301901R1003 CK1-02 2/351SAM340000R1001 MS132-0.16T 2/291SAM340000R1002 MS132-0.25T 2/291SAM340000R1003 MS132-0.4T 2/291SAM340000R1004 MS132-0.63T 2/291SAM340000R1005 MS132-1.0T 2/291SAM340000R1006 MS132-1.6T 2/291SAM340000R1007 MS132-2.5T 2/291SAM340000R1008 MS132-4.0T 2/291SAM340000R1009 MS132-6.3T 2/291SAM340000R1010 MS132-10T 2/291SAM340000R1011 MS132-16T 2/291SAM340000R1012 MS132-12T 2/291SAM340000R1013 MS132-20T 2/291SAM340000R1014 MS132-25T 2/291SAM340010R1001 MS132-0.16KT 2/301SAM340010R1002 MS132-0.25KT 2/301SAM340010R1003 MS132-0.4KT 2/301SAM340010R1004 MS132-0.63KT 2/301SAM340010R1005 MS132-1.0KT 2/301SAM340010R1006 MS132-1.6KT 2/301SAM340010R1007 MS132-2.5KT 2/301SAM340010R1008 MS132-4.0KT 2/301SAM340010R1009 MS132-6.3KT 2/301SAM340010R1010 MS132-10KT 2/301SAM340010R1011 MS132-16KT 2/301SAM340010R1013 MS132-20KT 2/301SAM340010R1014 MS132-25KT 2/301SAM350000R1001 MS132-0.16 2/111SAM350000R1002 MS132-0.25 2/111SAM350000R1003 MS132-0.4 2/111SAM350000R1004 MS132-0.63 2/111SAM350000R1005 MS132-1.0 2/111SAM350000R1006 MS132-1.6 2/111SAM350000R1007 MS132-2.5 2/111SAM350000R1008 MS132-4.0 2/111SAM350000R1009 MS132-6.3 2/111SAM350000R1010 MS132-10 2/111SAM350000R1011 MS132-16 2/111SAM350000R1012 MS132-12 2/111SAM350000R1013 MS132-20 2/111SAM350000R1014 MS132-25 2/111SAM350000R1015 MS132-32 2/111SAM350005R1001 MS132-0.16-HKF1-11 2/111SAM350005R1002 MS132-0.25-HKF1-11 2/111SAM350005R1003 MS132-0.4-HKF1-11 2/111SAM350005R1004 MS132-0.63-HKF1-11 2/111SAM350005R1005 MS132-1.0-HKF1-11 2/111SAM350005R1006 MS132-1.6-HKF1-11 2/1114
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage ABB MOTOR PROTECTION AND CONTROL 14/21SAM350005R1007 MS132-2.5-HKF1-11 2/111SAM350005R1008 MS132-4.0-HKF1-11 2/111SAM350005R1009 MS132-6.3-HKF1-11 2/111SAM350005R1010 MS132-10.0-HKF1-11 2/111SAM350005R1011 MS132-16.0-HKF1-11 2/111SAM350005R1012 MS132-12.0-HKF1-11 2/111SAM350005R1013 MS132-20-HKF1-11 2/111SAM350005R1014 MS132-25-HKF1-11 2/111SAM350005R1015 MS132-32-HKF1-11 2/111SAM350006R1011 MS132-16-HKF1-20 2/111SAM350010R1001 MS132-0.16K 2/121SAM350010R1002 MS132-0.25K 2/121SAM350010R1003 MS132-0.4K 2/121SAM350010R1004 MS132-0.63K 2/121SAM350010R1005 MS132-1.0K 2/121SAM350010R1006 MS132-1.6K 2/121SAM350010R1007 MS132-2.5K 2/121SAM350010R1008 MS132-4.0K 2/121SAM350010R1009 MS132-6.3K 2/121SAM350010R1010 MS132-10K 2/121SAM350010R1011 MS132-16K 2/121SAM350010R1013 MS132-20K 2/121SAM350010R1014 MS132-25K 2/121SAM350010R1015 MS132-32K 2/121SAM360000R1001 MO132-0.16 2/141SAM360000R1002 MO132-0.25 2/141SAM360000R1003 MO132-0.4 2/141SAM360000R1004 MO132-0.63 2/141SAM360000R1005 MO132-1.0 2/141SAM360000R1006 MO132-1.6 2/141SAM360000R1007 MO132-2.5 2/141SAM360000R1008 MO132-4.0 2/141SAM360000R1009 MO132-6.3 2/141SAM360000R1010 MO132-10 2/141SAM360000R1011 MO132-16 2/141SAM360000R1012 MO132-12 2/141SAM360000R1013 MO132-20 2/141SAM360000R1014 MO132-25 2/141SAM360000R1015 MO132-32 2/141SAM401920R1002 PS2-2-0-125 2/421SAM401920R1003 PS2-3-0-125 2/421SAM401920R1004 PS2-4-0-125 2/421SAM401920R1022 PS2-2-2-125 2/421SAM401920R1023 PS2-3-2-125 2/421SAM401920R1024 PS2-4-2-125 2/421SAM401921R1001 BS2-3 2/421SAM401922R1001 KA165 2/421SAM451000R1011 MS165-16 2/131SAM451000R1012 MS165-20 2/131SAM451000R1013 MS165-25 2/131SAM451000R1014 MS165-32 2/131SAM451000R1015 MS165-42 2/131SAM451000R1016 MS165-54 2/131SAM451000R1017 MS165-65 2/131SAM451000R1018 MS165-73 2/131SAM451000R1019 MS165-80 2/131SAM461000R1011 MO165-16 2/151SAM461000R1012 MO165-20 2/151SAM461000R1013 MO165-25 2/151SAM461000R1014 MO165-32 2/151SAM461000R1015 MO165-42 2/151SAM461000R1016 MO165-54 2/151SAM461000R1017 MO165-65 2/151SAM461000R1018 MO165-73 2/151SAM461000R1019 MO165-80 2/151SAM550000R1008 MS495-75 12/61SAM550000R1009 MS495-90 12/61SAT112000R1011 HF0.6-DOL-24VDC 10/81SAT113000R1011 HF0.6-DOLE-24VDC 10/81SAT115000R1011 HF0.6-ROL-24VDC 10/91SAT116000R1011 HF0.6-ROLE-24VDC 10/91SAT122000R1011 HF2.4-DOL-24VDC 10/81SAT123000R1011 HF2.4-DOLE-24VDC 10/81SAT125000R1011 HF2.4-ROL-24VDC 10/91SAT126000R1011 HF2.4-ROLE-24VDC 10/91SAT142000R1011 HF9-DOL-24VDC 10/81SAT143000R1011 HF9-DOLE-24VDC 10/81SAT144000R1011 HF9-R-24VDC 10/91SAT145000R1011 HF9-ROL-24VDC 10/91SAT146000R1011 HF9-ROLE-24VDC 10/91SAX101110R0001 DB16E 6/291SAX101910R1001 DB19EF 6/291SAX101911R1001 DRS-F-01 6/91SAX101911R1002 DRS-F-02 6/91SAX101911R1003 DRS-F-03 6/91SAX101911R1004 DRS-F-04 6/91SAX111001R1101 E16DU-0.32 6/291SAX111001R1102 E16DU-1.0 6/291SAX111001R1103 E16DU-2.7 6/291SAX111001R1104 E16DU-6.3 6/291SAX111001R1105 E16DU-18.9 6/29 EF19-18.9 12/381SAX121001R1101 EF19-0.32 6/291SAX121001R1102 EF19-1.0 6/291SAX121001R1103 EF19-2.7 6/291SAX121001R1104 EF19-6.3 6/291SAX121001R1105 EF19-18.9 6/291SAX201910R0001 DB45EF 6/291SAX211001R1101 EF45-30 12/381SAX211001R1102 EF45-45 12/381SAX221001R1101 EF45-30 6/291SAX221001R1102 EF45-45 6/291SAX331001R1101 EF65-70 6/331SAX331001R1102 EF65-56 6/331SAX341001R1101 EF96-100 6/331SAX341001R1102 EF96-56 6/331SAX351001R1101 EF146-150 6/331SAX501904R0001 LT200E 6/371SAX531001R1101 EF205-210 6/37 EF205-110 12/381SAX601904R0001 LT320E 6/371SAX611001R1101 EF370-380 6/371SAX701902R1001 DT500/AF460-L 6/411SAX701902R1011 DT500/AF460-S 6/411SAX701904R0002 LT460EF 6/411SAX721001R1101 EF460-500 6/411SAX801902R1001 DT800/AF750-L 6/411SAX801902R1011 DT800/AF750-S 6/411SAX801904R0002 LT750EF 6/411SAX821001R1101 EF750-800 6/411SAZ401110R0001 DB200 6/251SAZ401901R1001 LT200/A 6/251SAZ411201R1005 TA200DU-175 12/361SAZ411201R1006 TA200DU-200 12/361SAZ421201R1001 TA200DU-90 6/251SAZ421201R1002 TA200DU-110 6/251SAZ421201R1003 TA200DU-135 6/251SAZ421201R1004 TA200DU-150 6/251SAZ421201R1005 TA200DU-175 6/251SAZ421201R1006 TA200DU-200 6/251SAZ421301R1001 TA200DU-90-V1000 6/251SAZ421301R1002 TA200DU-110-V1000 6/251SAZ421301R1003 TA200DU-135-V1000 6/251SAZ421301R1004 TA200DU-150-V1000 6/251SAZ421301R1005 TA200DU-175-V1000 6/251SAZ421301R1006 TA200DU-200-V1000 6/251SAZ431201R1001 TF140DU-90 6/211SAZ431201R1002 TF140DU-110 6/211SAZ431201R1003 TF140DU-135 6/211SAZ431201R1004 TF140DU-142 6/211SAZ431301R1001 TF140DU-90-V1000 6/211SAZ431301R1002 TF140DU-110-V1000 6/211SAZ431301R1003 TF140DU-135-V1000 6/211SAZ431301R1004 TF140DU-142-V1000 6/211SAZ701901R0001 DB16 6/41SAZ701902R0001 DB42 6/91SAZ701903R1001 WRH-F 6/441SAZ701903R1011 WRB-400 6/441SAZ701903R1012 WRB-600 6/441SAZ701903R1013 WRB-1000 6/441SAZ701903R1030 WRBG 6/441SAZ711201R1005 T16-0.13 6/41SAZ711201R1008 T16-0.17 6/41SAZ711201R1009 T16-0.23 6/41SAZ711201R1013 T16-0.31 6/41SAZ711201R1014 T16-0.41 6/41SAZ711201R1017 T16-0.55 6/41SAZ711201R1021 T16-0.74 6/41SAZ711201R1023 T16-1.0 6/41SAZ711201R1025 T16-1.3 6/41SAZ711201R1028 T16-1.7 6/41SAZ711201R1031 T16-2.3 6/41SAZ711201R1033 T16-3.1 6/41SAZ711201R1035 T16-4.2 6/41SAZ711201R1038 T16-5.7 6/41SAZ711201R1040 T16-7.6 6/41SAZ711201R1043 T16-10 6/4, TF42-10 12/361SAZ711201R1045 T16-13 6/4 TF42-13 12/361SAZ711201R1047 T16-16 6/4 TF42-16 12/361SAZ711201R1051 TF42-24 12/361SAZ711201R1053 TF42-35 12/361SAZ711201R1055 TF42-38 12/361SAZ721201R1005 TF42-0.13 6/81SAZ721201R1008 TF42-0.17 6/81SAZ721201R1009 TF42-0.23 6/81SAZ721201R1013 TF42-0.31 6/81SAZ721201R1014 TF42-0.41 6/81SAZ721201R1017 TF42-0.55 6/81SAZ721201R1021 TF42-0.74 6/81SAZ721201R1023 TF42-1.0 6/81SAZ721201R1025 TF42-1.3 6/81SAZ721201R1028 TF42-1.7 6/81SAZ721201R1031 TF42-2.3 6/81SAZ721201R1033 TF42-3.1 6/81SAZ721201R1035 TF42-4.2 6/81SAZ721201R1038 TF42-5.7 6/81SAZ721201R1040 TF42-7.6 6/81SAZ721201R1043 TF42-10 6/81SAZ721201R1045 TF42-13 6/81SAZ721201R1047 TF42-16 6/81SAZ721201R1049 TF42-20 6/81SAZ721201R1051 TF42-24 6/81SAZ721201R1052 TF42-29 6/81SAZ721201R1053 TF42-35 6/81SAZ721201R1055 TF42-38 6/81SAZ801901R1001 DB65 6/131SAZ811201R1001 TF65-28 6/131SAZ811201R1002 TF65-33 6/1314
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/3ABB MOTOR PROTECTION AND CONTROL1SAZ811201R1003TF65-406/131SAZ811201R1004TF65-476/131SAZ811201R1005TF65-536/131SAZ811201R1006TF65-606/131SAZ811201R1007TF65-676/131SAZ901901R1001 DB96 6/171SAZ911201R1001TF96-516/171SAZ911201R1002TF96-606/171SAZ911201R1003TF96-686/171SAZ911201R1004TF96-786/171SAZ911201R1005TF96-876/171SAZ911201R1006TF96-966/171SBH101001R2022 NS22E-20 5/301SBH101001R2031 NS31E-20 5/301SBH101001R2040 NS40E-20 5/301SBH101001R2044 NS44E-20 5/301SBH101001R2053 NS53E-20 5/301SBH101001R2062 NS62E-20 5/301SBH101001R2071NS71E-205/301SBH101001R2080 NS80E-20 5/301SBH101001R2622 NS22E-26 5/301SBH101001R2631 NS31E-26 5/301SBH101001R2640 NS40E-26 5/301SBH101001R2644 NS44E-26 5/301SBH101001R2653 NS53E-26 5/301SBH101001R2662 NS62E-26 5/301SBH101001R2671NS71E-265/301SBH101001R2680 NS80E-26 5/301SBH101004R2022 NS22ES-20 5/731SBH101004R2031 NS31ES-20 5/731SBH101004R2040 NS40ES-20 5/731SBH101004R2044 NS44ES-20 5/731SBH101004R2053 NS53ES-20 5/731SBH101004R2062 NS62ES-20 5/731SBH101004R2071 NS71ES-20 5/731SBH101004R2080 NS80ES-20 5/731SBH101004R2622 NS22ES-26 5/731SBH101004R2631 NS31ES-26 5/731SBH101004R2640 NS40ES-26 5/731SBH101004R2644 NS44ES-26 5/731SBH101004R2653 NS53ES-26 5/731SBH101004R2662 NS62ES-26 5/731SBH101004R2671 NS71ES-26 5/731SBH101004R2680 NS80ES-26 5/731SBH103001R8122 NSL22E-81 5/311SBH103001R8131 NSL31E-81 5/311SBH103001R8140 NSL40E-81 5/311SBH103001R8144 NSL44E-81 5/311SBH103001R8153 NSL53E-81 5/311SBH103001R8162 NSL62E-81 5/311SBH103001R8171NSL71E-815/311SBH103001R8180 NSL80E-81 5/311SBH103004R8122 NSL22ES-81 5/741SBH103004R8131 NSL31ES-81 5/741SBH103004R8140 NSL40ES-81 5/741SBH103004R8144 NSL44ES-81 5/741SBH103004R8153 NSL53ES-81 5/741SBH103004R8162 NSL62ES-81 5/741SBH103004R8171 NSL71ES-81 5/741SBH103004R8180 NSL80ES-81 5/741SBH136001R2022 NFZ22E-20 3/2101SBH136001R2031 NFZ31E-20 3/2101SBH136001R2039 NFZ33/11-20 3/2141SBH136001R2040 NFZ40E-20 3/2101SBH136001R2044 NFZ44E-20 3/2141SBH136001R2053 NFZ53E-20 3/2141SBH136001R2059 NFZ51/11-20 3/2141SBH136001R2062 NFZ62E-20 3/2141SBH136001R2071 NFZ71E-20 3/2141SBH136001R2080 NFZ80E-20 3/2141SBH136001R2122 NFZ22E-21 3/2101SBH136001R2131NFZ31E-213/2101SBH136001R2139 NFZ33/11-21 3/2141SBH136001R2140 NFZ40E-21 3/2101SBH136001R2144 NFZ44E-21 3/2141SBH136001R2153 NFZ53E-21 3/2141SBH136001R2159 NFZ51/11-21 3/2141SBH136001R2162 NFZ62E-21 3/2141SBH136001R2171NFZ71E-213/2141SBH136001R2180 NFZ80E-21 3/2141SBH136001R2222 NFZ22E-22 3/2101SBH136001R2231 NFZ31E-22 3/2101SBH136001R2239 NFZ33/11-22 3/2141SBH136001R2240 NFZ40E-22 3/2101SBH136001R2244 NFZ44E-22 3/2141SBH136001R2253 NFZ53E-22 3/2141SBH136001R2259 NFZ51/11-22 3/2141SBH136001R2262 NFZ62E-22 3/2141SBH136001R2271 NFZ71E-22 3/2141SBH136001R2280 NFZ80E-22 3/2141SBH136001R2322 NFZ22E-23 3/2101SBH136001R2331 NFZ31E-23 3/2101SBH136001R2339 NFZ33/11-23 3/2141SBH136001R2340 NFZ40E-23 3/2101SBH136001R2344 NFZ44E-23 3/2141SBH136001R2353 NFZ53E-23 3/2141SBH136001R2359 NFZ51/11-23 3/2141SBH136001R2362 NFZ62E-23 3/2141SBH136001R2371 NFZ71E-23 3/2141SBH136001R2380 NFZ80E-23 3/2141SBH136001R3022 NFZ22E-30 3/2091SBH136001R3031 NFZ31E-30 3/2091SBH136001R3040 NFZ40E-30 3/2091SBH136001R3044 NFZ44E-30 3/2131SBH136001R3053 NFZ53E-30 3/2131SBH136001R3062 NFZ62E-30 3/2131SBH136001R3071 NFZ71E-30 3/2131SBH136001R3080 NFZ80E-30 3/2131SBH136005R2022 NFZ22EK-20 3/2211SBH136005R2031 NFZ31EK-20 3/2211SBH136005R2040 NFZ40EK-20 3/2211SBH136005R2044 NFZ44EK-20 3/2211SBH136005R2053 NFZ53EK-20 3/2211SBH136005R2062 NFZ62EK-20 3/2211SBH136005R2071 NFZ71EK-20 3/2211SBH136005R2080 NFZ80EK-20 3/2211SBH136005R2122 NFZ22EK-21 3/2211SBH136005R2131 NFZ31EK-21 3/2211SBH136005R2140 NFZ40EK-21 3/2211SBH136005R2144 NFZ44EK-21 3/2211SBH136005R2153 NFZ53EK-21 3/2211SBH136005R2162 NFZ62EK-21 3/2211SBH136005R2171 NFZ71EK-21 3/2211SBH136005R2180 NFZ80EK-21 3/2211SBH136005R2222 NFZ22EK-22 3/2211SBH136005R2231 NFZ31EK-22 3/2211SBH136005R2240 NFZ40EK-22 3/2211SBH136005R2244 NFZ44EK-22 3/2211SBH136005R2253 NFZ53EK-22 3/2211SBH136005R2262 NFZ62EK-22 3/2211SBH136005R2271 NFZ71EK-22 3/2211SBH136005R2280 NFZ80EK-22 3/2211SBH136005R2322 NFZ22EK-23 3/2211SBH136005R2331 NFZ31EK-23 3/2211SBH136005R2340 NFZ40EK-23 3/2211SBH136005R2344 NFZ44EK-23 3/2211SBH136005R2353 NFZ53EK-23 3/2211SBH136005R2362 NFZ62EK-23 3/2211SBH136005R2371 NFZ71EK-23 3/2211SBH136005R2380 NFZ80EK-23 3/2211SBH136005R3022 NFZ22EK-30 3/2201SBH136005R3031 NFZ31EK-30 3/2201SBH136005R3040 NFZ40EK-30 3/2201SBH136005R3044 NFZ44EK-30 3/2201SBH136005R3053 NFZ53EK-30 3/2201SBH136005R3062 NFZ62EK-30 3/2201SBH136005R3071 NFZ71EK-30 3/2201SBH136005R3080 NFZ80EK-30 3/2201SBH137001R1122NF22E-113/2081SBH137001R1131NF31E-113/2081SBH137001R1139 NF 1-11 3/2121SBH137001R1140 NF40E-11 3/2081SBH137001R1144 NF44E-11 3/2121SBH137001R1153NF53E-113/2121SBH137001R1159NF51/11-113/2121SBH137001R1162NF62E-113/2121SBH137001R1171NF71E-113/2121SBH137001R1180 NF80E-11 3/2121SBH137001R1222NF22E-123/2081SBH137001R1231NF31E-123/2081SBH137001R1239 NF33/11-12 3/2121SBH137001R1240 NF40E-12 3/2081SBH137001R1244 NF44E-12 3/2121SBH137001R1253 NF53E-12 3/2121SBH137001R1259 NF51/11-12 3/2121SBH137001R1262 NF62E-12 3/2121SBH137001R1271NF71E-123/2121SBH137001R1280 NF80E-12 3/2121SBH137001R1322NF22E-133/2081SBH137001R1331NF31E-133/2081SBH137001R1339 NF33/11-13 3/2121SBH137001R1340 NF40E-13 3/2081SBH137001R1344 NF44E-13 3/2121SBH137001R1353 NF53E-13 3/2121SBH137001R1359 NF51/11-13 3/2121SBH137001R1362 NF62E-13 3/2121SBH137001R1371NF71E-133/2121SBH137001R1380 NF80E-13 3/2121SBH137001R1422 NF22E-14 3/2081SBH137001R1431NF31E-143/2081SBH137001R1439 NF33/11-14 3/2121SBH137001R1440 NF40E-14 3/2081SBH137001R1444 NF44E-14 3/2121SBH137001R1453 NF53E-14 3/2121SBH137001R1459 NF51/11-14 3/2121SBH137001R1462 NF62E-14 3/2121SBH137001R1471NF71E-143/2121SBH137001R1480 NF80E-14 3/2121SBH137005R1122 NF22EK-11 3/2191SBH137005R1131NF31EK-113/2191SBH137005R1140 NF40EK-11 3/2191SBH137005R1144 NF44EK-11 3/2191SBH137005R1153 NF53EK-11 3/2191SBH137005R1162 NF62EK-11 3/2191SBH137005R1171NF71EK-113/2191SBH137005R1180 NF80EK-11 3/2191SBH137005R1222 NF22EK-12 3/2191SBH137005R1231 NF31EK-12 3/2191SBH137005R1240 NF40EK-12 3/2191SBH137005R1244 NF44EK-12 3/2191SBH137005R1253 NF53EK-12 3/21914
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePageABB MOTOR PROTECTION AND CONTROL 14/41SBH137005R1262 NF62EK-12 3/2191SBH137005R1271 NF71EK-12 3/2191SBH137005R1280 NF80EK-12 3/2191SBH137005R1322 NF22EK-13 3/2191SBH137005R1331 NF31EK-13 3/2191SBH137005R1340 NF40EK-13 3/2191SBH137005R1344 NF44EK-13 3/2191SBH137005R1353 NF53EK-13 3/2191SBH137005R1362 NF62EK-13 3/2191SBH137005R1371 NF71EK-13 3/2191SBH137005R1380 NF80EK-13 3/2191SBH137005R1422 NF22EK-14 3/2191SBH137005R1431 NF31EK-14 3/2191SBH137005R1440 NF40EK-14 3/2191SBH137005R1444 NF44EK-14 3/2191SBH137005R1453 NF53EK-14 3/2191SBH137005R1462 NF62EK-14 3/2191SBH137005R1471 NF71EK-14 3/2191SBH137005R1480 NF80EK-14 3/2191SBK104035R2800 DRAS09-28P 9/21SBK104035R2900 DRAS09-29P 9/21SBK104135R2600 DRAS09-26N 9/21SBK104135R2700 DRAS09-27N 9/21SBK104235R2000 DRAS09-20S 9/21SBK104335R8100 DRASL09-81S 9/21SBK104335R8300 DRASL09-83S 9/21SBK114035R2800 DRAS12-28P 9/21SBK114035R2900 DRAS12-29P 9/21SBK114135R2600 DRAS12-26N 9/21SBK114135R2700DRAS12-27N9/21SBK114235R2000 DRAS12-20S 9/21SBK114335R8100 DRASL12-81S 9/21SBK114335R8300 DRASL12-83S 9/21SBK124035R2800 DRAS16-28P 9/21SBK124035R2900 DRAS16-29P 9/21SBK124135R2600 DRAS16-26N 9/21SBK124135R2700 DRAS16-27N 9/21SBK124235R2000 DRAS16-20S 9/21SBK124335R8100 DRASL16-81S 9/21SBK124335R8300 DRASL16-83S 9/21SBK134037R1400 DRAF09-14P 9/81SBK134137R1300DRAF09-13N9/81SBK134237R1100DRAF09-11S9/81SBK134238R1100 DRAF09-11U 9/81SBK134238R1300 DRAF09-13U 9/81SBK134238R1400 DRAF09-14U 9/81SBK154037R1400 DRAF12-14P 9/81SBK154137R1300DRAF12-13N9/81SBK154237R1100DRAF12-11S9/81SBK154238R1100 DRAF12-11U 9/81SBK154238R1300 DRAF12-13U 9/81SBK154238R1400 DRAF12-14U 9/81SBK174037R1400 DRAF16-14P 9/81SBK174137R1300DRAF16-13N9/81SBK174237R1100DRAF16-11S9/81SBK174238R1100DRAF16-11U9/81SBK174238R1300DRAF16-13U9/81SBK174238R1400 DRAF16-14U 9/81SBL101001R2001AS09-30-01-205/81SBL101001R2010AS09-30-10-205/81SBL101001R2032AS09-30-32-205/101SBL101001R2601AS09-30-01-265/81SBL101001R2610AS09-30-10-265/81SBL101001R2632AS09-30-32-265/101SBL101004R2001 AS09-30-01S-20 5/561SBL101004R2010 AS09-30-10S-20 5/561SBL101004R2032 AS09-30-32S-20 5/581SBL101004R2601 AS09-30-01S-26 5/561SBL101004R2610 AS09-30-10S-26 5/561SBL101004R2632 AS09-30-32S-26 5/581SBL103001R8101ASL09-30-01-815/91SBL103001R8110ASL09-30-10-815/91SBL103001R8132ASL09-30-32-815/111SBL103004R8101 ASL09-30-01S-81 5/571SBL103004R8110 ASL09-30-10S-81 5/571SBL103004R8132 ASL09-30-32S-81 5/591SBL111001R2001AS12-30-01-205/81SBL111001R2010AS12-30-10-205/81SBL111001R2032AS12-30-32-205/101SBL111001R2601AS12-30-01-265/81SBL111001R2610AS12-30-10-265/81SBL111001R2632AS12-30-32-265/101SBL111004R2001AS12-30-01S-205/561SBL111004R2010AS12-30-10S-205/561SBL111004R2032AS12-30-32S-205/581SBL111004R2601AS12-30-01S-265/561SBL111004R2610AS12-30-10S-265/561SBL111004R2632AS12-30-32S-265/581SBL113001R8101ASL12-30-01-815/91SBL113001R8110ASL12-30-10-815/91SBL113001R8132ASL12-30-32-815/111SBL113004R8101ASL12-30-01S-815/571SBL113004R8110ASL12-30-10S-815/571SBL113004R8132ASL12-30-32S-815/591SBL121001R2001AS16-30-01-205/81SBL121001R2010AS16-30-10-205/81SBL121001R2032AS16-30-32-205/101SBL121001R2601AS16-30-01-265/81SBL121001R2610AS16-30-10-265/81SBL121001R2632AS16-30-32-265/101SBL121004R2001 AS16-30-01S-20 5/561SBL121004R2010 AS16-30-10S-20 5/561SBL121004R2032 AS16-30-32S-20 5/581SBL121004R2601AS16-30-01S-265/561SBL121004R2610AS16-30-10S-265/561SBL121004R2632AS16-30-32S-265/581SBL123001R8101ASL16-30-01-815/91SBL123001R8110ASL16-30-10-815/91SBL123001R8132ASL16-30-32-815/111SBL123004R8101 ASL16-30-01S-81 5/571SBL123004R8110 ASL16-30-10S-81 5/571SBL123004R8132 ASL16-30-32S-81 5/591SBL136001R1110AF09Z-30-10-1112/61SBL136001R2001 AF09Z-30-01-20 3/161SBL136001R2010 AF09Z-30-10-20 3/161SBL136001R2022 AF09Z-30-22-20 3/391SBL136001R2101AF09Z-30-01-213/161SBL136001R2110AF09Z-30-10-213/161SBL136001R2122AF09Z-30-22-213/391SBL136001R2201AF09Z-30-01-223/161SBL136001R2210AF09Z-30-10-223/161SBL136001R2222AF09Z-30-22-223/391SBL136001R2301AF09Z-30-01-233/161SBL136001R2310AF09Z-30-10-233/161SBL136001R2322AF09Z-30-22-233/391SBL136001R3001 AF09Z-30-01-30 3/151SBL136001R3010 AF09Z-30-10-30 3/151SBL136005R2001 AF09Z-30-01K-20 3/921SBL136005R2010 AF09Z-30-10K-20 3/921SBL136005R2101AF09Z-30-01K-213/921SBL136005R2110AF09Z-30-10K-213/921SBL136005R2201 AF09Z-30-01K-22 3/921SBL136005R2210 AF09Z-30-10K-22 3/921SBL136005R2301 AF09Z-30-01K-23 3/921SBL136005R2310 AF09Z-30-10K-23 3/921SBL136005R3001 AF09Z-30-01K-30 3/911SBL136005R3010 AF09Z-30-10K-30 3/911SBL136082R3022 AFS09Z-30-22-30 3/1141SBL136201R2000 AF09Z-40-00-20 3/1361SBL136201R2100AF09Z-40-00-213/1361SBL136201R2200 AF09Z-40-00-22 3/1361SBL136201R2300 AF09Z-40-00-23 3/1361SBL136201R3000 AF09Z-40-00-30 3/1351SBL136501R2000 AF09Z-22-00-20 3/1361SBL136501R2100AF09Z-22-00-213/1361SBL136501R2200 AF09Z-22-00-22 3/1361SBL136501R2300 AF09Z-22-00-23 3/1361SBL136501R3000 AF09Z-22-00-30 3/1351SBL137001R1101AF09-30-01-113/141SBL137001R1110AF09-30-10-113/141SBL137001R1122AF09-30-22-113/381SBL137001R1201AF09-30-01-123/141SBL137001R1210AF09-30-10-123/141SBL137001R1222AF09-30-22-123/381SBL137001R1301AF09-30-01-133/141SBL137001R1310AF09-30-10-133/141SBL137001R1322AF09-30-22-133/381SBL137001R1401AF09-30-01-143/141SBL137001R1410AF09-30-10-143/141SBL137001R1422AF09-30-22-143/381SBL137005R1101AF09-30-01K-113/901SBL137005R1110AF09-30-10K-113/901SBL137005R1201AF09-30-01K-123/901SBL137005R1210AF09-30-10K-123/901SBL137005R1301AF09-30-01K-133/901SBL137005R1310AF09-30-10K-133/901SBL137005R1401AF09-30-01K-143/901SBL137005R1410AF09-30-10K-143/901SBL137082R1122AFS09-30-22-113/1141SBL137082R1322AFS09-30-22-133/1141SBL137201R1100AF09-40-00-113/1341SBL137201R1200AF09-40-00-123/1341SBL137201R1300AF09-40-00-133/1341SBL137201R1400AF09-40-00-143/1341SBL137501R1100AF09-22-00-113/1341SBL137501R1200AF09-22-00-123/1341SBL137501R1300AF09-22-00-133/1341SBL137501R1400AF09-22-00-143/1341SBL156001R1110AF12Z-30-10-1112/61SBL156001R2001 AF12Z-30-01-20 3/161SBL156001R2010 AF12Z-30-10-20 3/161SBL156001R2022 AF12Z-30-22-20 3/391SBL156001R2101AF12Z-30-01-213/161SBL156001R2110AF12Z-30-10-213/161SBL156001R2122AF12Z-30-22-213/391SBL156001R2201AF12Z-30-01-223/161SBL156001R2210AF12Z-30-10-223/161SBL156001R2222AF12Z-30-22-223/391SBL156001R2301AF12Z-30-01-233/161SBL156001R2310AF12Z-30-10-233/161SBL156001R2322AF12Z-30-22-233/391SBL156001R3001 AF12Z-30-01-30 3/151SBL156001R3010 AF12Z-30-10-30 3/151SBL156005R2001 AF12Z-30-01K-20 3/921SBL156005R2010 AF12Z-30-10K-20 3/921SBL156005R2101AF12Z-30-01K-213/921SBL156005R2110AF12Z-30-10K-213/921SBL156005R2201 AF12Z-30-01K-22 3/921SBL156005R2210 AF12Z-30-10K-22 3/921SBL156005R2301 AF12Z-30-01K-23 3/921SBL156005R2310 AF12Z-30-10K-23 3/9214
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/5ABB MOTOR PROTECTION AND CONTROL1SBL156005R3001 AF12Z-30-01K-30 3/911SBL156005R3010 AF12Z-30-10K-30 3/911SBL156082R3022 AFS12Z-30-22-30 3/1141SBL157001R1101AF12-30-01-113/141SBL157001R1110AF12-30-10-113/141SBL157001R1122AF12-30-22-113/381SBL157001R1201AF12-30-01-123/141SBL157001R1210AF12-30-10-123/141SBL157001R1222AF12-30-22-123/381SBL157001R1301AF12-30-01-133/141SBL157001R1310AF12-30-10-133/141SBL157001R1322AF12-30-22-133/381SBL157001R1401AF12-30-01-143/141SBL157001R1410AF12-30-10-143/141SBL157001R1422AF12-30-22-143/381SBL157005R1101AF12-30-01K-113/901SBL157005R1110AF12-30-10K-113/901SBL157005R1201AF12-30-01K-123/901SBL157005R1210AF12-30-10K-123/901SBL157005R1301AF12-30-01K-133/901SBL157005R1310AF12-30-10K-133/901SBL157005R1401 AF12-30-01K-14 3/901SBL157005R1410AF12-30-10K-143/901SBL157082R1122AFS12-30-22-113/1141SBL157082R1322AFS12-30-22-133/1141SBL176001R1110AF16Z-30-10-1112/61SBL176001R2001AF16Z-30-01-203/161SBL176001R2010AF16Z-30-10-203/161SBL176001R2022AF16Z-30-22-203/391SBL176001R2101AF16Z-30-01-213/161SBL176001R2110AF16Z-30-10-213/161SBL176001R2122AF16Z-30-22-213/391SBL176001R2201AF16Z-30-01-223/161SBL176001R2210AF16Z-30-10-223/161SBL176001R2222AF16Z-30-22-223/391SBL176001R2301AF16Z-30-01-233/161SBL176001R2310AF16Z-30-10-233/161SBL176001R2322AF16Z-30-22-233/391SBL176001R3001AF16Z-30-01-303/151SBL176001R3010AF16Z-30-10-303/151SBL176005R2001 AF16Z-30-01K-20 3/921SBL176005R2010 AF16Z-30-10K-20 3/921SBL176005R2101AF16Z-30-01K-213/921SBL176005R2110AF16Z-30-10K-213/921SBL176005R2201AF16Z-30-01K-223/921SBL176005R2210AF16Z-30-10K-223/921SBL176005R2301AF16Z-30-01K-233/921SBL176005R2310AF16Z-30-10K-233/921SBL176005R3001 AF16Z-30-01K-30 3/911SBL176005R3010 AF16Z-30-10K-30 3/911SBL176082R3022AFS16Z-30-22-303/1141SBL176201R2000 AF16Z-40-00-20 3/1361SBL176201R2100AF16Z-40-00-213/1361SBL176201R2200AF16Z-40-00-223/1361SBL176201R2300AF16Z-40-00-233/1361SBL176201R3000 AF16Z-40-00-30 3/1351SBL176501R2000 AF16Z-22-00-20 3/1361SBL176501R2100AF16Z-22-00-213/1361SBL176501R2200AF16Z-22-00-223/1361SBL176501R2300AF16Z-22-00-233/1361SBL176501R3000 AF16Z-22-00-30 3/1351SBL177001R1101AF16-30-01-113/141SBL177001R1110AF16-30-10-113/141SBL177001R1122AF16-30-22-113/381SBL177001R1201AF16-30-01-123/141SBL177001R1210AF16-30-10-123/141SBL177001R1222AF16-30-22-123/381SBL177001R1301AF16-30-01-133/141SBL177001R1310AF16-30-10-133/141SBL177001R1322AF16-30-22-133/381SBL177001R1401AF16-30-01-143/141SBL177001R1410AF16-30-10-143/141SBL177001R1422AF16-30-22-143/381SBL177005R1101AF16-30-01K-113/901SBL177005R1110AF16-30-10K-113/901SBL177005R1201AF16-30-01K-123/901SBL177005R1210AF16-30-10K-123/901SBL177005R1301AF16-30-01K-133/901SBL177005R1310AF16-30-10K-133/901SBL177005R1401AF16-30-01K-143/901SBL177005R1410AF16-30-10K-143/901SBL177082R1122AFS16-30-22-113/1141SBL177082R1322AFS16-30-22-133/1141SBL177201R1100AF16-40-00-113/1341SBL177201R1200AF16-40-00-123/1341SBL177201R1300AF16-40-00-133/1341SBL177201R1400AF16-40-00-143/1341SBL177501R1100AF16-22-00-113/1341SBL177501R1200AF16-22-00-123/1341SBL177501R1300AF16-22-00-133/1341SBL177501R1400AF16-22-00-143/1341SBL181022R8010UA16-30-103/2001SBL181022R8110UA16-30-103/2001SBL181022R8310UA16-30-103/2001SBL181022R8410UA16-30-103/2001SBL181022R8510UA16-30-103/2001SBL181022R8610UA16-30-103/2001SBL181022R8810UA16-30-103/2001SBL181024R8010 UA16-30-10RA 3/1941SBL181024R8110UA16-30-10RA3/1941SBL181024R8410UA16-30-10RA3/1941SBL181024R8510UA16-30-10RA3/1941SBL181024R8610UA16-30-10RA3/1941SBL181024R8810UA16-30-10RA3/1941SBL236001R1100 AF26Z-30-00-11 12/61SBL236001R2000 AF26Z-30-00-20 3/161SBL236001R2011AF26Z-30-11-203/251SBL236001R2022 AF26Z-30-22-20 3/391SBL236001R2100 AF26Z-30-00-21 3/161SBL236001R2111AF26Z-30-11-213/251SBL236001R2122AF26Z-30-22-213/391SBL236001R2200 AF26Z-30-00-22 3/161SBL236001R2211AF26Z-30-11-223/251SBL236001R2222 AF26Z-30-22-22 3/391SBL236001R2300 AF26Z-30-00-23 3/161SBL236001R2311AF26Z-30-11-233/251SBL236001R2322 AF26Z-30-22-23 3/391SBL236001R3000 AF26Z-30-00-30 3/151SBL236005R2000 AF26Z-30-00K-20 3/921SBL236005R2100 AF26Z-30-00K-21 3/921SBL236005R2200 AF26Z-30-00K-22 3/921SBL236005R2300 AF26Z-30-00K-23 3/921SBL236005R3000 AF26Z-30-00K-30 3/911SBL236082R3022 AFS26Z-30-22-30 3/1141SBL236201R2000 AF26Z-40-00-20 3/1361SBL236201R2100 AF26Z-40-00-21 3/1361SBL236201R2200 AF26Z-40-00-22 3/1361SBL236201R2300 AF26Z-40-00-23 3/1361SBL236501R2000 AF26Z-22-00-20 3/1361SBL236501R2100 AF26Z-22-00-21 3/1361SBL236501R2200 AF26Z-22-00-22 3/1361SBL236501R2300 AF26Z-22-00-23 3/1361SBL237001R1100AF26-30-00-113/141SBL237001R1111AF26-30-11-113/241SBL237001R1122AF26-30-22-113/381SBL237001R1200 AF26-30-00-12 3/141SBL237001R1211AF26-30-11-123/241SBL237001R1222AF26-30-22-123/381SBL237001R1300 AF26-30-00-13 3/141SBL237001R1311AF26-30-11-133/241SBL237001R1322AF26-30-22-133/381SBL237001R1400 AF26-30-00-14 3/141SBL237001R1411AF26-30-11-143/241SBL237001R1422AF26-30-22-143/381SBL237005R1100 AF26-30-00K-11 3/901SBL237005R1200 AF26-30-00K-12 3/901SBL237005R1300 AF26-30-00K-13 3/901SBL237005R1400 AF26-30-00K-14 3/901SBL237082R1122AFS26-30-22-113/1141SBL237082R1322AFS26-30-22-133/1141SBL237201R1100AF26-40-00-113/1341SBL237201R1200AF26-40-00-123/1341SBL237201R1300AF26-40-00-133/1341SBL237201R1400 AF26-40-00-14 3/1341SBL237501R1100AF26-22-00-113/1341SBL237501R1200 AF26-22-00-12 3/1341SBL237501R1300 AF26-22-00-13 3/1341SBL237501R1400 AF26-22-00-14 3/1341SBL241022R8010 UA26-30-10 3/2001SBL241022R8110UA26-30-103/2001SBL241022R8310UA26-30-103/2001SBL241022R8410 UA26-30-10 3/2001SBL241022R8510UA26-30-103/2001SBL241022R8610UA26-30-103/2001SBL241022R8810 UA26-30-10 3/2001SBL241024R8010 UA26-30-10RA 3/1941SBL241024R8110UA26-30-10RA3/1941SBL241024R8410 UA26-30-10RA 3/1941SBL241024R8510 UA26-30-10RA 3/1941SBL241024R8610 UA26-30-10RA 3/1941SBL241024R8810 UA26-30-10RA 3/1941SBL276001R1100AF30Z-30-00-1112/61SBL276001R2000 AF30Z-30-00-20 3/161SBL276001R2011AF30Z-30-11-203/251SBL276001R2022 AF30Z-30-22-20 3/391SBL276001R2100 AF30Z-30-00-21 3/161SBL276001R2111AF30Z-30-11-213/251SBL276001R2122AF30Z-30-22-213/391SBL276001R2200 AF30Z-30-00-22 3/161SBL276001R2211AF30Z-30-11-223/251SBL276001R2222AF30Z-30-22-223/391SBL276001R2300 AF30Z-30-00-23 3/161SBL276001R2311AF30Z-30-11-233/251SBL276001R2322 AF30Z-30-22-23 3/391SBL276001R3000 AF30Z-30-00-30 3/151SBL276005R2000 AF30Z-30-00K-20 3/921SBL276005R2100 AF30Z-30-00K-21 3/921SBL276005R2200 AF30Z-30-00K-22 3/921SBL276005R2300 AF30Z-30-00K-23 3/921SBL276005R3000 AF30Z-30-00K-30 3/911SBL276082R3022 AFS30Z-30-22-30 3/1141SBL277001R1100AF30-30-00-113/141SBL277001R1111AF30-30-11-113/241SBL277001R1122AF30-30-22-113/381SBL277001R1200 AF30-30-00-12 3/141SBL277001R1211AF30-30-11-123/241SBL277001R1222AF30-30-22-123/381SBL277001R1300 AF30-30-00-13 3/141SBL277001R1311AF30-30-11-133/241SBL277001R1322AF30-30-22-133/381SBL277001R1400 AF30-30-00-14 3/1414
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage ABB MOTOR PROTECTION AND CONTROL 14/61SBL277001R1411 AF30-30-11-14 3/241SBL277001R1422 AF30-30-22-14 3/381SBL277005R1100 AF30-30-00K-11 3/901SBL277005R1200 AF30-30-00K-12 3/901SBL277005R1300 AF30-30-00K-13 3/901SBL277005R1400 AF30-30-00K-14 3/901SBL277082R1122 AFS30-30-22-11 3/1141SBL277082R1322 AFS30-30-22-13 3/1141SBL281022R8010 UA30-30-10 3/2001SBL281022R8110 UA30-30-10 3/2001SBL281022R8310 UA30-30-10 3/2001SBL281022R8410 UA30-30-10 3/2001SBL281022R8510 UA30-30-10 3/2001SBL281022R8610 UA30-30-10 3/2001SBL281022R8810 UA30-30-10 3/2001SBL281024R8010 UA30-30-10RA 3/1941SBL281024R8110 UA30-30-10RA 3/1941SBL281024R8410 UA30-30-10RA 3/1941SBL281024R8510 UA30-30-10RA 3/1941SBL281024R8610 UA30-30-10RA 3/1941SBL281024R8810 UA30-30-10RA 3/1941SBL296001R1100 AF38Z-30-00-11 12/361SBL296001R2000 AF38Z-30-00-20 3/161SBL296001R2011 AF38Z-30-11-20 3/251SBL296001R2022 AF38Z-30-22-20 3/391SBL296001R2100 AF38Z-30-00-21 3/161SBL296001R2111 AF38Z-30-11-21 3/251SBL296001R2122 AF38Z-30-22-21 3/391SBL296001R2200 AF38Z-30-00-22 3/161SBL296001R2211 AF38Z-30-11-22 3/251SBL296001R2222 AF38Z-30-22-22 3/391SBL296001R2300 AF38Z-30-00-23 3/161SBL296001R2311 AF38Z-30-11-23 3/251SBL296001R2322 AF38Z-30-22-23 3/391SBL296001R3000 AF38Z-30-00-30 3/151SBL296005R2000 AF38Z-30-00K-20 3/921SBL296005R2100 AF38Z-30-00K-21 3/921SBL296005R2200 AF38Z-30-00K-22 3/921SBL296005R2300 AF38Z-30-00K-23 3/921SBL296005R3000 AF38Z-30-00K-30 3/911SBL296082R3022 AFS38Z-30-22-30 3/1141SBL296201R2000 AF38Z-40-00-20 3/1361SBL296201R2100 AF38Z-40-00-21 3/1361SBL296201R2200 AF38Z-40-00-22 3/1361SBL296201R2300 AF38Z-40-00-23 3/1361SBL296501R2000 AF38Z-22-00-20 3/1361SBL296501R2100 AF38Z-22-00-21 3/1361SBL296501R2200 AF38Z-22-00-22 3/1361SBL296501R2300 AF38Z-22-00-23 3/1361SBL297001R1100 AF38-30-00-11 3/141SBL297001R1111 AF38-30-11-11 3/241SBL297001R1122 AF38-30-22-11 3/381SBL297001R1200 AF38-30-00-12 3/141SBL297001R1211 AF38-30-11-12 3/241SBL297001R1222 AF38-30-22-12 3/381SBL297001R1300 AF38-30-00-13 3/141SBL297001R1311 AF38-30-11-13 3/241SBL297001R1322 AF38-30-22-13 3/381SBL297001R1400 AF38-30-00-14 3/141SBL297001R1411 AF38-30-11-14 3/241SBL297001R1422 AF38-30-22-14 3/381SBL297005R1100 AF38-30-00K-11 3/901SBL297005R1200 AF38-30-00K-12 3/901SBL297005R1300 AF38-30-00K-13 3/901SBL297005R1400 AF38-30-00K-14 3/901SBL297082R1122 AFS38-30-22-11 3/1141SBL297082R1322 AFS38-30-22-13 3/1141SBL297201R1100 AF38-40-00-11 3/1341SBL297201R1200 AF38-40-00-12 3/1341SBL297201R1300 AF38-40-00-13 3/1341SBL297201R1400 AF38-40-00-14 3/1341SBL297501R1100 AF38-22-00-11 3/1341SBL297501R1200 AF38-22-00-12 3/1341SBL297501R1300 AF38-22-00-13 3/1341SBL297501R1400 AF38-22-00-14 3/1341SBL347001R1100 AF40-30-00-11 3/171SBL347001R1111 AF40-30-11-11 3/271SBL347001R1122 AF40-30-22-11 3/401SBL347001R1200 AF40-30-00-12 3/171SBL347001R1211 AF40-30-11-12 3/271SBL347001R1222 AF40-30-22-12 3/401SBL347001R1300 AF40-30-00-13 3/171SBL347001R1311 AF40-30-11-13 3/271SBL347001R1322 AF40-30-22-13 3/401SBL347001R1400 AF40-30-00-14 3/171SBL347001R1411 AF40-30-11-14 3/271SBL347001R1422 AF40-30-22-14 3/401SBL347082R1122 AFS40-30-22-11 3/1151SBL347082R1322 AFS40-30-22-13 3/1151SBL347201R1100 AF40-40-00-11 3/1371SBL347201R1200 AF40-40-00-12 3/1371SBL347201R1300 AF40-40-00-13 3/1371SBL347201R1400 AF40-40-00-14 3/1371SBL347501R1100 AF40-22-00-11 3/1371SBL347501R1200 AF40-22-00-12 3/1371SBL347501R1300 AF40-22-00-13 3/1371SBL347501R1400 AF40-22-00-14 3/1371SBL351022R8000 UA50-30-00 3/2011SBL351022R8100 UA50-30-00 3/2011SBL351022R8300 UA50-30-00 3/2011SBL351022R8400 UA50-30-00 3/2011SBL351022R8500 UA50-30-00 3/2011SBL351022R8600 UA50-30-00 3/2011SBL351022R8800 UA50-30-00 3/2011SBL351024R8000 UA50-30-00RA 3/1951SBL351024R8100 UA50-30-00RA 3/1951SBL351024R8400 UA50-30-00RA 3/1951SBL351024R8500 UA50-30-00RA 3/1951SBL351024R8600 UA50-30-00RA 3/1951SBL351024R8800 UA50-30-00RA 3/1951SBL367001R1100 AF52-30-00-11 3/171SBL367001R1111 AF52-30-11-11 3/271SBL367001R1122 AF52-30-22-11 3/401SBL367001R1200 AF52-30-00-12 3/171SBL367001R1211 AF52-30-11-12 3/271SBL367001R1222 AF52-30-22-12 3/401SBL367001R1300 AF52-30-00-13 3/171SBL367001R1311 AF52-30-11-13 3/271SBL367001R1322 AF52-30-22-13 3/401SBL367001R1400 AF52-30-00-14 3/171SBL367001R1411 AF52-30-11-14 3/271SBL367001R1422 AF52-30-22-14 3/401SBL367082R1122 AFS52-30-22-11 3/1151SBL367082R1322 AFS52-30-22-13 3/1151SBL367201R1100 AF52-40-00-11 3/1371SBL367201R1200 AF52-40-00-12 3/1371SBL367201R1300 AF52-40-00-13 3/1371SBL367201R1400 AF52-40-00-14 3/1371SBL371022R8000 UA63-30-00 3/2011SBL371022R8100 UA63-30-00 3/2011SBL371022R8300 UA63-30-00 3/2011SBL371022R8400 UA63-30-00 3/2011SBL371022R8500 UA63-30-00 3/2011SBL371022R8600 UA63-30-00 3/2011SBL371022R8800 UA63-30-00 3/2011SBL371024R8000 UA63-30-00RA 3/1951SBL371024R8100 UA63-30-00RA 3/1951SBL371024R8400 UA63-30-00RA 3/1951SBL371024R8500 UA63-30-00RA 3/1951SBL371024R8600 UA63-30-00RA 3/1951SBL371024R8800 UA63-30-00RA 3/1951SBL387001R1100 AF65-30-00-11 3/171SBL387001R1111 AF65-30-11-11 3/271SBL387001R1122 AF65-30-22-11 3/401SBL387001R1200 AF65-30-00-12 3/171SBL387001R1211 AF65-30-11-12 3/271SBL387001R1222 AF65-30-22-12 3/401SBL387001R1300 AF65-30-00-13 3/171SBL387001R1311 AF65-30-11-13 3/271SBL387001R1322 AF65-30-22-13 3/401SBL387001R1400 AF65-30-00-14 3/171SBL387001R1411 AF65-30-11-14 3/271SBL387001R1422 AF65-30-22-14 3/401SBL387082R1122 AFS65-30-22-11 3/1151SBL387082R1322 AFS65-30-22-13 3/1151SBL397001R1100 AF80-30-00-11 3/171SBL397001R1111 AF80-30-11-11 3/271SBL397001R1122 AF80-30-22-11 3/401SBL397001R1200 AF80-30-00-12 3/171SBL397001R1211 AF80-30-11-12 3/271SBL397001R1222 AF80-30-22-12 3/401SBL397001R1300 AF80-30-00-13 3/171SBL397001R1311 AF80-30-11-13 3/271SBL397001R1322 AF80-30-22-13 3/401SBL397001R1400 AF80-30-00-14 3/171SBL397001R1411 AF80-30-11-14 3/271SBL397001R1422 AF80-30-22-14 3/401SBL397082R1122 AFS80-30-22-11 3/1151SBL397082R1322 AFS80-30-22-13 3/1151SBL397201R1100 AF80-40-00-11 3/1371SBL397201R1200 AF80-40-00-12 3/1371SBL397201R1300 AF80-40-00-13 3/1371SBL397201R1400 AF80-40-00-14 3/1371SBL397501R1100 AF80-22-00-11 3/1371SBL397501R1200 AF80-22-00-12 3/1371SBL397501R1300 AF80-22-00-13 3/1371SBL397501R1400 AF80-22-00-14 3/1371SBL407001R1100 AF96-30-00-11 3/171SBL407001R1111 AF96-30-11-11 3/271SBL407001R1122 AF96-30-22-11 3/401SBL407001R1200 AF96-30-00-12 3/171SBL407001R1211 AF96-30-11-12 3/271SBL407001R1222 AF96-30-22-12 3/401SBL407001R1300 AF96-30-00-13 3/171SBL407001R1311 AF96-30-11-13 3/271SBL407001R1322 AF96-30-22-13 3/401SBL407001R1400 AF96-30-00-14 3/171SBL407001R1411 AF96-30-11-14 3/271SBL407001R1422 AF96-30-22-14 3/401SBL407082R1122 AFS96-30-22-11 3/1151SBL407082R1322 AFS96-30-22-13 3/1151SBL411022R8000 UA75-30-00 3/2011SBL411022R8100 UA75-30-00 3/2011SBL411022R8300 UA75-30-00 3/2011SBL411022R8400 UA75-30-00 3/2011SBL411022R8500 UA75-30-00 3/2011SBL411022R8600 UA75-30-00 3/2011SBL411022R8800 UA75-30-00 3/2011SBL411024R8000 UA75-30-00RA 3/1951SBL411024R8100 UA75-30-00RA 3/1951SBL411024R8400 UA75-30-00RA 3/19514
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/7ABB MOTOR PROTECTION AND CONTROL1SBL411024R8500 UA75-30-00RA 3/1951SBL411024R8600 UA75-30-00RA 3/1951SBL411024R8800 UA75-30-00RA 3/1951SBL411025R8000 GA75-10-00 3/1781SBL411025R8011GA75-10-113/1781SBL411025R8100GA75-10-003/1781SBL411025R8111GA75-10-113/1781SBL411025R8300 GA75-10-00 3/1781SBL411025R8311GA75-10-113/1781SBL411025R8400 GA75-10-00 3/1781SBL411025R8411GA75-10-113/1781SBL411025R8500 GA75-10-00 3/1781SBL411025R8511GA75-10-113/1781SBL411025R8600 GA75-10-00 3/1781SBL411025R8611GA75-10-113/1781SBL411025R8800 GA75-10-00 3/1781SBL411025R8811GA75-10-113/1781SBL419025R8000 GAE75-10-00 3/1791SBL419025R8011GAE75-10-113/1791SBL419025R8100 GAE75-10-00 3/1791SBL419025R8111GAE75-10-113/1791SBL419025R8300 GAE75-10-00 3/1791SBL419025R8311GAE75-10-113/1791SBL419025R8600 GAE75-10-00 3/1791SBL419025R8611GAE75-10-113/1791SBL419025R8700 GAE75-10-00 3/1791SBL419025R8711GAE75-10-113/1791SBL419025R8800 GAE75-10-00 3/1791SBL419025R8811GAE75-10-113/1791SBL419025R8900 GAE75-10-00 3/1791SBL419025R8911GAE75-10-113/1791SBN010010R1001 CA5-01 3/2721SBN010010R1010 CA5-10 3/2721SBN010011R1001 CC5-01 3/2721SBN010011R1010 CC5-10 3/2721SBN010013R1001 CB5-01 3/2501SBN010013R1010 CB5-10 3/2501SBN010015R1001 CE5-01D0.1 3/2341SBN010015R1010 CE5-10D0.1 3/2341SBN010016R1001 CE5-01W0.1 3/2341SBN010016R1010 CE5-10W0.1 3/2341SBN010017R1001 CE5-01D2 3/2341SBN010017R1010 CE5-10D2 3/2341SBN010018R1001 CE5-01W2 3/2341SBN010018R1010 CE5-10W2 3/2341SBN010020R1011 CAL5-11 3/2721SBN010040R1004 CA5-04E 3/2721SBN010040R1018 CA5-11/11E 3/2721SBN010040R1022 CA5-22E 3/2721SBN010040R1031 CA5-31E 3/2721SBN010040R1040 CA5-40E 3/2721SBN010040R1104 CA5-04M 3/2721SBN010040R1113 CA5-13M 3/2721SBN010040R1118 CA5-11/11M 3/2721SBN010040R1122 CA5-22M 3/2721SBN010040R1131 CA5-31M 3/2721SBN010110R1001 CA4-01 3/230 BER96-412/8 BEA65-412/8, BER65-412/37 KM1 : 1 x CA4-10 12/851SBN010110R1010CA4-103/230 BEA65-412/6 BEA38-412/6 BEA26-412/7 BER96-412/8, BER65-412/37 BER38-412/37 KM1 : 1 x CA4-10 12/85 KM1 : 1 x CA4-10 12/851SBN010110T1001 CA4-01-T 3/2301SBN010110T1010CA4-10-T3/2301SBN010111R1001CC4-013/2301SBN010111R1010CC4-103/2301SBN010120R1011CAL4-113/2301SBN010120T1011CAL4-11-T3/2301SBN010134R1011CAL4-11K3/2321SBN010140R1004 CA4-04E 3/2301SBN010140R1022 CA4-22E 3/2301SBN010140R1031 CA4-31E 3/2301SBN010140R1040 CA4-40E 3/2301SBN010140R1104 CA4-04M 3/2301SBN010140R1113CA4-13M3/2301SBN010140R1122 CA4-22M 3/2301SBN010140R1131CA4-31M3/2301SBN010140R1204 CA4-04N 3/2301SBN010140R1213 CA4-13N 3/2301SBN010140R1222 CA4-22N 3/2301SBN010140R1231 CA4-31N 3/2301SBN010140R1240 CA4-40N 3/2301SBN010140R1322 CA4-22U 3/2301SBN010140R1331 CA4-31U 3/2301SBN010140R1340 CA4-40U 3/2301SBN010146R1022 CA4-22EK 3/2321SBN010146R1031 CA4-31EK 3/2321SBN010146R1040 CA4-40EK 3/2321SBN010146R1104 CA4-04MK 3/2321SBN010146R1113CA4-13MK3/2321SBN010146R1122 CA4-22MK 3/2321SBN010146R1131CA4-31MK3/2321SBN010146R1204 CA4-04NK 3/2321SBN010146R1213 CA4-13NK 3/2321SBN010146R1222 CA4-22NK 3/2321SBN010146R1231 CA4-31NK 3/2321SBN010146R1240 CA4-40NK 3/2321SBN010151R1011CAT4-11E3/2301SBN010151R1111CAT4-11M3/2301SBN010151R1311CAT4-11U3/2301SBN010160R1001 CA4-01K 3/2321SBN010160R1010 CA4-10K 3/2321SBN010160T1001 CA4-01K-T 3/2321SBN010160T1010 CA4-10K-T 3/2321SBN011010T1001 CA3-01 5/131SBN011010T1010CA3-105/13 BER16C-3 12/65 KM1: 1 x CA3-10 12/691SBN011019T1001CA3-01S5/611SBN011019T1010CA3-10S5/611SBN020112R1000 TEF4-ON 3/245 CT-ERS.21S 12/851SBN020113R1000 TEF4S-ON 3/2451SBN020114R1000 TEF4-OFF 3/2451SBN020115R1000 TEF4S-OFF 3/2451SBN020312R1000 TEF5-ON 3/2781SBN020314R1000 TEF5-OFF 3/2781SBN021012R1000 TEF3-ON 5/131SBN021014R1000 TEF3-OFF 5/131SBN030105T1000 VM4 3/2481SBN030111R1000 VEM4 3/248 BEA38-412/8 BEA16-412/8 BEA26-412/9 BER38-412/37 BER16-412/37 BEY38-412/85 BEY16-412/851SBN030113R1000 VEM4K 3/2641SBN030210R1000 VE5-2 3/2821SBN031005T1000 VM3 5/13 BER16C-3 12/65 BEY16C-3 12/691SBN033405T1000 VM96-4 3/248 BER96-412/8 BEA65-412/8 BER65-412/37 BEY96-412/85 BEY65-412/851SBN040100R1010 WA4-10 3/2541SBN040100R1011 WA4-11 3/2541SBN040100R1012 WA4-12 3/2541SBN040100R1013 WA4-13 3/2541SBN040100R1014 WA4-14 3/2541SBN040200R1011 WA4-96-11 3/2541SBN040200R1012 WA4-96-12 3/2541SBN040200R1013 WA4-96-13 3/2541SBN040200R1014 WA4-96-14 3/2541SBN050010R1000 RV5/50 3/2861SBN050010R1001 RV5/133 3/2861SBN050010R1002 RV5/250 3/2861SBN050010R1003 RV5/440 3/2861SBN050020R1000 RT5/32 3/2861SBN050020R1001 RT5/65 3/2861SBN050020R1002 RT5/90 3/2861SBN050020R1003 RT5/150 3/2861SBN050020R1004 RT5/264 3/2861SBN050100R1000 RC5-1/50 5/131SBN050100R1001 RC5-1/133 5/131SBN050100R1002 RC5-1/250 5/131SBN050100R1003 RC5-1/440 5/131SBN050200R1000 RC5-2/50 3/2861SBN050200R1001 RC5-2/133 3/2861SBN050200R1002 RC5-2/250 3/2861SBN050200R1003 RC5-2/440 3/2861SBN060100R1000 RA4 3/2521SBN060100T1000 RA4-T 3/2521SBN060300R1000 RA5-1 3/2881SBN060300T1000 RA5-1 3/2881SBN070156T1000 LDC4 3/2561SBN070159T1000 LDC4K 3/2561SBN071303T1000 LY16-4 3/2611SBN071305R1000 LF16-4 3/2611SBN071306R1000 LG16-4 3/2611SBN072303T1000 LY38-4 3/2611SBN072304R1000 LH38-4 3/2611SBN072305R1000 LF38-4 3/2611SBN072308R1000 LD38-4 3/2581SBN073508R1000 LD75 3/2921SBN073552R1002 LK75-F 3/2931SBN073552R1003 LK75-L 3/2931SBN080906R1001 BEA7/325 4/491SBN080906R1002 BEA7/132 4/491SBN081006T1000 BEA16-3 5/131SBN081012R1000 BER16C-3 5/131SBN081018R2000 BEY16C-3 5/131SBN081020R1000 BEA16-3U 5/611SBN081306T1000 BEA16-4 3/2621SBN081311R1000 BER16-4 3/262 BEA16-412/81SBN081313R2000 BEY16-4 3/2631SBN081321T1000 BEA16-4K 3/2641SBN082306T1000 BEA26-4 3/2621SBN082306T2000 BEA38-4 3/2621SBN082311R1000 BER38-4 3/262 BEA38-412/8 BEA26-412/91SBN082321T2000 BEA38-4K 3/26414
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePageABB MOTOR PROTECTION AND CONTROL 14/81SBN082713R2000 BEY38-4 3/2631SBN083406R1000 BEA65-4 3/2621SBN083411R1000 BER65-4 3/262 BEA65-412/81SBN083413R2000 BEY65-4 3/2631SBN083911R1000 BER96-4 3/2621SBN083913R2000 BEY96-4 3/2631SBN101035R1000 FR16AS-12VARS 9/21SBN101337R1000 FR16AF-12 9/91SBN101338R1000 FR16AF-12U 9/91SBN110000R1000 BA5-50 3/2561SBN110108T1000 BX4 3/2561SBN110109W1000 BX4-CA 3/2561SBN110120W1000 BB4 3/2481SBN110122T1000 BDT4 3/2571SBN111020R1000 BB3 5/501SBN111403R1000 BP16 3/2851SBN112303T1000 BP38-4 3/2571SBN113403T1000 BP65-4 3/2571SBN113405R1000 BPR65-4 3/262 BEA65-412/61SBN113903T1000 BP96-4 3/2571SBN123401R1000 LT65-30 3/2591SBN123402R1000 LT52-40 3/2591SBN123901R1000 LT96-30 3/2591SBN123902R1000 LT80-40 3/2591SBN151410R8006 ZA16 3/2951SBN151410R8106 ZA16 3/2951SBN151410R8406 ZA16 3/2951SBN151410R8506 ZA16 3/2951SBN151410R8606 ZA16 3/2951SBN151410R8806 ZA16 3/2951SBN152410R8006 ZA40 3/2951SBN152410R8106 ZA40 3/2951SBN152410R8406 ZA40 3/2951SBN152410R8506 ZA40 3/2951SBN152410R8606 ZA40 3/2951SBN152410R8806 ZA40 3/2951SBN153510R8006 ZA75 3/2951SBN153510R8106 ZA75 3/2951SBN153510R8406 ZA75 3/2951SBN153510R8506 ZA75 3/2951SBN153510R8606 ZA75 3/2951SBN153510R8806 ZA75 3/2951SBN163502R1000 ZLU50 3/2951SBN163702R1000 ZLU63 3/2951SBN164102R1000 ZLU75 3/2951SCA101647R1001OXS6X852/451SCA101655R1001OXS6X1302/451SCA101659R1001OXS6X1802/451SCA108043R1001 OXS6X105 2/451SDA054126R1 T4S 320 PR221-I In320 12/231SDA054335R1 T5S 400 PR221-I In400 12/231SDA054405R1 T5S 630 PR221-I In630 12/231SDA054527R1 T4S 250 PR222MP In200 12/211SDA054553R1 T5S 400 PR222MP In320 12/211SDA054554R1 T5S 400 PR222MP In400 12/211SDA054988R1EN_DASH3/701SDA055016R11SDA066917R13/701SDA055020R11SDA054988R13/701SDA067355R1 Ekip M-LIU In160 12/211SDA068164R1 XT2S 160 12/211SDA068480R1 XT4S 250 Ekip I In250 12/231SDA076530R1 XT2S 160 MA 160 12/231SFA616162R1014KPR-101L6/41SFA739001R1001EF1250DU-12506/411SFL427001R1100AF116-30-00-113/191SFL427001R1111AF116-30-11-113/291SFL427001R1122AF116-30-22-113/421SFL427001R1200 AF116-30-00-12 3/191SFL427001R1211AF116-30-11-123/291SFL427001R1222AF116-30-22-123/421SFL427001R1300 AF116-30-00-13 3/191SFL427001R1311AF116-30-11-133/291SFL427001R1322AF116-30-22-133/421SFL427001R1400 AF116-30-00-14 3/191SFL427001R1411AF116-30-11-143/291SFL427001R1422AF116-30-22-143/421SFL427001R3300 AF116-30-00-33 3/201SFL427001R3311AF116-30-11-333/301SFL427001R3322AF116-30-22-333/431SFL427001R3400 AF116-30-00-34 3/201SFL427001R3411AF116-30-11-343/301SFL427001R3422 AF116-30-22-34 3/431SFL427002R1100 AF116-30-00B-11 3/191SFL427002R1111AF116-30-11B-113/291SFL427002R1122AF116-30-22B-113/421SFL427002R1200 AF116-30-00B-12 3/191SFL427002R1211AF116-30-11B-123/291SFL427002R1222AF116-30-22B-123/421SFL427002R1300 AF116-30-00B-13 3/191SFL427002R1311AF116-30-11B-133/291SFL427002R1322AF116-30-22B-133/421SFL427002R1400 AF116-30-00B-14 3/191SFL427002R1411AF116-30-11B-143/291SFL427002R1422 AF116-30-22B-14 3/421SFL427002R3300 AF116-30-00B-33 3/201SFL427002R3311AF116-30-11B-333/301SFL427002R3322 AF116-30-22B-33 3/431SFL427002R3400 AF116-30-00B-34 3/201SFL427002R3411AF116-30-11B-343/301SFL427002R3422 AF116-30-22B-34 3/431SFL427101R1100AF116-40-00-113/1391SFL427101R1111AF116-40-11-113/1421SFL427101R1122AF116-40-22-113/1451SFL427101R1200AF116-40-00-123/1391SFL427101R1211AF116-40-11-123/1421SFL427101R1222AF116-40-22-123/1451SFL427101R1300AF116-40-00-133/1391SFL427101R1311AF116-40-11-133/1421SFL427101R1322AF116-40-22-133/1451SFL427101R1400AF116-40-00-143/1391SFL427101R1411AF116-40-11-143/1421SFL427101R1422AF116-40-22-143/1451SFL427102R1100AF116-40-00B-113/1391SFL427102R1111AF116-40-11B-113/1421SFL427102R1122AF116-40-22B-113/1451SFL427102R1200AF116-40-00B-123/1391SFL427102R1211AF116-40-11B-123/1421SFL427102R1222AF116-40-22B-123/1451SFL427102R1300AF116-40-00B-133/1391SFL427102R1311AF116-40-11B-133/1421SFL427102R1322AF116-40-22B-133/1451SFL427102R1400 AF116-40-00B-14 3/1391SFL427102R1411AF116-40-11B-143/1421SFL427102R1422AF116-40-22B-143/1451SFL431022R8000 UA95-30-00 3/2021SFL431022R8100UA95-30-003/2021SFL431022R8300 UA95-30-00 3/2021SFL431022R8400 UA95-30-00 3/2021SFL431022R8500 UA95-30-00 3/2021SFL431022R8600 UA95-30-00 3/2021SFL431022R8800 UA95-30-00 3/2021SFL431024R8000 UA95-30-00RA 3/1961SFL431024R8100 UA95-30-00RA 3/1961SFL431024R8400 UA95-30-00RA 3/1961SFL431024R8500 UA95-30-00RA 3/1961SFL431024R8600 UA95-30-00RA 3/1961SFL431024R8800 UA95-30-00RA 3/1961SFL447001R1100 AF140-30-00-11 3/191SFL447001R1111AF140-30-11-113/291SFL447001R1122AF140-30-22-113/421SFL447001R1200 AF140-30-00-12 3/191SFL447001R1211AF140-30-11-123/291SFL447001R1222AF140-30-22-123/421SFL447001R1300 AF140-30-00-13 3/191SFL447001R1311AF140-30-11-133/291SFL447001R1322AF140-30-22-133/421SFL447001R1400 AF140-30-00-14 3/191SFL447001R1411AF140-30-11-143/291SFL447001R1422 AF140-30-22-13 3/421SFL447001R3300 AF140-30-00-33 3/201SFL447001R3311AF140-30-11-333/301SFL447001R3322 AF140-30-22-33 3/431SFL447001R3400 AF140-30-00-34 3/201SFL447001R3411AF140-30-11-343/301SFL447001R3422 AF140-30-22-34 3/431SFL447002R1100 AF140-30-00B-11 3/191SFL447002R1111AF140-30-11B-113/291SFL447002R1122AF140-30-22B-113/421SFL447002R1200 AF140-30-00B-12 3/191SFL447002R1211AF140-30-11B-123/291SFL447002R1222 AF140-30-22B-12 3/421SFL447002R1300 AF140-30-00B-13 3/191SFL447002R1311AF140-30-11B-133/291SFL447002R1322 AF140-30-22B-13 3/421SFL447002R1400 AF140-30-00B-14 3/191SFL447002R1411AF140-30-11B-143/291SFL447002R1422 AF140-30-22B-14 3/421SFL447002R3300 AF140-30-00B-33 3/201SFL447002R3311AF140-30-11B-333/301SFL447002R3322 AF140-30-22B-33 3/431SFL447002R3400 AF140-30-00B-34 3/201SFL447002R3411 AF140-30-11B-34 3/301SFL447002R3422 AF140-30-22B-34 3/431SFL447101R1100AF140-40-00-113/1391SFL447101R1111AF140-40-11-113/1421SFL447101R1122AF140-40-22-113/1451SFL447101R1200AF140-40-00-123/1391SFL447101R1211AF140-40-11-123/1421SFL447101R1222AF140-40-22-123/1451SFL447101R1300AF140-40-00-133/1391SFL447101R1311AF140-40-11-133/1421SFL447101R1322AF140-40-22-133/1451SFL447101R1400AF140-40-00-143/1391SFL447101R1411AF140-40-11-143/1421SFL447101R1422AF140-40-22-143/1451SFL447102R1100AF140-40-00B-113/1391SFL447102R1111AF140-40-11B-113/1421SFL447102R1122AF140-40-22B-113/1451SFL447102R1200AF140-40-00B-123/1391SFL447102R1211AF140-40-11B-123/1421SFL447102R1222AF140-40-22B-123/1451SFL447102R1300AF140-40-00B-133/1391SFL447102R1311AF140-40-11B-133/1421SFL447102R1322AF140-40-22B-133/1451SFL447102R1400 AF140-40-00B-14 3/1391SFL447102R1411AF140-40-11B-143/1421SFL447102R1422AF140-40-22B-143/1451SFL451022R8000 UA110-30-00 3/2021SFL451022R8100 UA110-30-00 3/20214
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/9ABB MOTOR PROTECTION AND CONTROL1SFL451022R8300 UA110-30-00 3/2021SFL451022R8400 UA110-30-00 3/2021SFL451022R8500 UA110-30-00 3/2021SFL451022R8600 UA110-30-00 3/2021SFL451022R8800 UA110-30-00 3/2021SFL451024R8000 UA110-30-00RA 3/1961SFL451024R8100 UA110-30-00RA 3/1961SFL451024R8400 UA110-30-00RA 3/1961SFL451024R8500 UA110-30-00RA 3/1961SFL451024R8600 UA110-30-00RA 3/1961SFL451024R8800 UA110-30-00RA 3/1961SFL467001R1100AF146-30-00-113/191SFL467001R1111AF146-30-11-113/291SFL467001R1122AF146-30-22-113/421SFL467001R1200 AF146-30-00-12 3/191SFL467001R1211AF146-30-11-123/291SFL467001R1222AF146-30-22-123/421SFL467001R1300 AF146-30-00-13 3/191SFL467001R1311AF146-30-11-133/291SFL467001R1322AF146-30-22-133/421SFL467001R1400 AF146-30-00-14 3/191SFL467001R1411AF146-30-11-143/291SFL467001R1422AF146-30-22-143/421SFL467001R3300 AF146-30-00-33 3/201SFL467001R3311AF146-30-11-333/301SFL467001R3322 AF146-30-22-33 3/431SFL467001R3400 AF146-30-00-34 3/201SFL467001R3411AF146-30-11-343/301SFL467001R3422 AF146-30-22-34 3/431SFL467002R1100 AF146-30-00B-11 3/191SFL467002R1111AF146-30-11B-113/291SFL467002R1122AF146-30-22B-113/421SFL467002R1200 AF146-30-00B-12 3/191SFL467002R1211AF146-30-11B-123/291SFL467002R1222AF146-30-22B-123/421SFL467002R1300 AF146-30-00B-13 3/191SFL467002R1311AF146-30-11B-133/291SFL467002R1322 AF146-30-22B-13 3/421SFL467002R1400 AF146-30-00B-14 3/191SFL467002R1411AF146-30-11B-143/291SFL467002R1422 AF146-30-22B-14 3/421SFL467002R3300 AF146-30-00B-33 3/201SFL467002R3311AF146-30-11B-333/301SFL467002R3322 AF146-30-22B-33 3/431SFL467002R3400 AF146-30-00B-34 3/201SFL467002R3411AF146-30-11B-343/301SFL467002R3422 AF146-30-22B-34 3/431SFL487002R1100 AF190-30-00-11 3/211SFL487002R1111AF190-30-11-113/311SFL487002R1122AF190-30-22-113/441SFL487002R1200 AF190-30-00-12 3/211SFL487002R1211AF190-30-11-123/311SFL487002R1222AF190-30-22-123/441SFL487002R1300 AF190-30-00-13 3/211SFL487002R1311AF190-30-11-133/311SFL487002R1322AF190-30-22-133/441SFL487002R1400 AF190-30-00-14 3/211SFL487002R1411AF190-30-11-143/311SFL487002R1422 AF190-30-22-14 3/441SFL487002R3300 AF190-30-00-33 3/221SFL487002R3311AF190-30-11-333/321SFL487002R3322 AF190-30-22-33 3/451SFL487002R3400 AF190-30-00-34 3/221SFL487002R3411AF190-30-11-343/321SFL487002R3422 AF190-30-22-34 3/451SFL487102R1100AF190-40-00-113/1401SFL487102R1111AF190-40-11-113/1431SFL487102R1122AF190-40-22-113/1461SFL487102R1200AF190-40-00-123/1401SFL487102R1211AF190-40-11-123/1431SFL487102R1222AF190-40-22-123/1461SFL487102R1300AF190-40-00-133/1401SFL487102R1311AF190-40-11-133/1431SFL487102R1322AF190-40-22-133/1461SFL487102R1400 AF190-40-00-14 3/1401SFL487102R1411AF190-40-11-143/1431SFL487102R1422AF190-40-22-143/1461SFL497025R6911GAF185-10-113/1801SFL497025R7011GAF185-10-113/1801SFL497025R7211 GAF185-10-11 3/1801SFL527002R1100AF205-30-00-113/211SFL527002R1111AF205-30-11-113/311SFL527002R1122AF205-30-22-113/441SFL527002R1200 AF205-30-00-12 3/211SFL527002R1211AF205-30-11-123/311SFL527002R1222AF205-30-22-123/441SFL527002R1300 AF205-30-00-13 3/211SFL527002R1311AF205-30-11-133/311SFL527002R1322AF205-30-22-133/441SFL527002R1400 AF205-30-00-14 3/211SFL527002R1411AF205-30-11-143/311SFL527002R1422AF205-30-22-143/441SFL527002R3300 AF205-30-00-33 3/221SFL527002R3311AF205-30-11-333/321SFL527002R3322 AF205-30-22-33 3/451SFL527002R3400 AF205-30-00-34 3/221SFL527002R3411AF205-30-11-343/321SFL527002R3422 AF205-30-22-34 3/451SFL527102R1100AF205-40-00-113/1401SFL527102R1111AF205-40-11-113/1431SFL527102R1122AF205-40-22-113/1461SFL527102R1200AF205-40-00-123/1401SFL527102R1211AF205-40-11-123/1431SFL527102R1222AF205-40-22-123/1461SFL527102R1300AF205-40-00-133/1401SFL527102R1311AF205-40-11-133/1431SFL527102R1322AF205-40-22-133/1461SFL527102R1400AF205-40-00-143/1401SFL527102R1411AF205-40-11-143/1431SFL527102R1422AF205-40-22-143/1461SFL547002R1100 AF265-30-00-11 3/211SFL547002R1111AF265-30-11-113/311SFL547002R1122AF265-30-22-113/441SFL547002R1200 AF265-30-00-12 3/211SFL547002R1211AF265-30-11-123/311SFL547002R1222AF265-30-22-123/441SFL547002R1300 AF265-30-00-13 3/211SFL547002R1311AF265-30-11-133/311SFL547002R1322AF265-30-22-133/441SFL547002R1400 AF265-30-00-14 3/211SFL547002R1411AF265-30-11-143/311SFL547002R1422 AF265-30-22-14 3/441SFL547002R3300 AF265-30-00-33 3/221SFL547002R3311AF265-30-11-333/321SFL547002R3322 AF265-30-22-33 3/451SFL547002R3400 AF265-30-00-34 3/221SFL547002R3411AF265-30-11-343/321SFL547002R3422 AF265-30-22-34 3/451SFL547102R1100AF265-40-00-113/1401SFL547102R1111AF265-40-11-113/1431SFL547102R1122AF265-40-22-113/1461SFL547102R1200AF265-40-00-123/1401SFL547102R1211AF265-40-11-123/1431SFL547102R1222AF265-40-22-123/1461SFL547102R1300AF265-40-00-133/1401SFL547102R1311AF265-40-11-133/1431SFL547102R1322AF265-40-22-133/1461SFL547102R1400 AF265-40-00-14 3/1401SFL547102R1411AF265-40-11-143/1431SFL547102R1422AF265-40-22-143/1461SFL557025R6911GAF300-10-113/1801SFL557025R7011GAF300-10-113/1801SFL557025R7211GAF300-10-113/1801SFL577001R6811AF400-30-113/341SFL577001R6822 AF400-30-22 3/471SFL577001R6911AF400-30-113/341SFL577001R6922 AF400-30-22 3/471SFL577001R7011AF400-30-113/341SFL577001R7022AF400-30-223/471SFL577001R7111AF400-30-113/341SFL577001R7122AF400-30-223/471SFL587002R1100 AF305-30-00-11 3/211SFL587002R1111AF305-30-11-113/311SFL587002R1122AF305-30-22-113/441SFL587002R1200 AF305-30-00-12 3/211SFL587002R1211AF305-30-11-123/311SFL587002R1222AF305-30-22-123/441SFL587002R1300 AF305-30-00-13 3/211SFL587002R1311AF305-30-11-133/311SFL587002R1322AF305-30-22-133/441SFL587002R1400 AF305-30-00-14 3/211SFL587002R1411AF305-30-11-143/311SFL587002R1422 AF305-30-22-14 3/441SFL587002R3300 AF305-30-00-33 3/221SFL587002R3311AF305-30-11-333/321SFL587002R3322 AF305-30-22-33 3/451SFL587002R3400 AF305-30-00-34 3/221SFL587002R3411AF305-30-11-343/321SFL587002R3422 AF305-30-22-34 3/451SFL587102R1100AF305-40-00-113/1401SFL587102R1111AF305-40-11-113/1431SFL587102R1122AF305-40-22-113/1461SFL587102R1200AF305-40-00-123/1401SFL587102R1211AF305-40-11-123/1431SFL587102R1222AF305-40-22-123/1461SFL587102R1300AF305-40-00-133/1401SFL587102R1311AF305-40-11-133/1431SFL587102R1322AF305-40-22-133/1461SFL587102R1400AF305-40-00-143/1401SFL587102R1411AF305-40-11-143/1431SFL587102R1422AF305-40-22-143/1461SFL597001R6811AF460-30-113/341SFL597001R6822 AF460-30-22 3/471SFL597001R6911AF460-30-113/341SFL597001R6922 AF460-30-22 3/471SFL597001R7011AF460-30-113/341SFL597001R7022AF460-30-223/471SFL597001R7111AF460-30-113/341SFL597001R7122AF460-30-223/471SFL597025R6811GAF460-10-113/1811SFL597025R6911GAF460-10-113/1811SFL597025R7011GAF460-10-113/1811SFL597025R7111GAF460-10-113/1811SFL607002R1100 AF370-30-00-11 3/211SFL607002R1111AF370-30-11-113/311SFL607002R1122AF370-30-22-113/441SFL607002R1200 AF370-30-00-12 3/211SFL607002R1211AF370-30-11-123/311SFL607002R1222 AF370-30-22-12 3/441SFL607002R1300 AF370-30-00-13 3/211SFL607002R1311AF370-30-11-133/3114
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage ABB MOTOR PROTECTION AND CONTROL 14/101SFL607002R1322 AF370-30-22-13 3/441SFL607002R1400 AF370-30-00-14 3/211SFL607002R1411 AF370-30-11-14 3/311SFL607002R1422 AF370-30-22-14 3/441SFL607002R3300 AF370-30-00-33 3/221SFL607002R3311 AF370-30-11-33 3/321SFL607002R3322 AF370-30-22-33 3/451SFL607002R3400 AF370-30-00-34 3/221SFL607002R3411 AF370-30-11-34 3/321SFL607002R3422 AF370-30-22-34 3/451SFL607102R1100 AF370-40-00-11 3/1401SFL607102R1111 AF370-40-11-11 3/1431SFL607102R1122 AF370-40-22-11 3/1461SFL607102R1200 AF370-40-00-12 3/1401SFL607102R1211 AF370-40-11-12 3/1431SFL607102R1222 AF370-40-22-12 3/1461SFL607102R1300 AF370-40-00-13 3/1401SFL607102R1311 AF370-40-11-13 3/1431SFL607102R1322 AF370-40-22-13 3/1461SFL607102R1400 AF370-40-00-14 3/1401SFL607102R1411 AF370-40-11-14 3/1431SFL607102R1422 AF370-40-22-14 3/1461SFL617001R6811 AF580-30-11 3/341SFL617001R6822 AF580-30-22 3/471SFL617001R6911 AF580-30-11 3/341SFL617001R6922 AF580-30-22 3/471SFL617001R7011 AF580-30-11 3/341SFL617001R7022 AF580-30-22 3/471SFL617001R7111 AF580-30-11 3/341SFL617001R7122 AF580-30-22 3/471SFL637001R6811 AF750-30-11 3/341SFL637001R6822 AF750-30-22 3/471SFL637001R6911 AF750-30-11 3/341SFL637001R6922 AF750-30-22 3/471SFL637001R7011 AF750-30-11 3/341SFL637001R7022 AF750-30-22 3/471SFL637001R7111 AF750-30-11 3/341SFL637001R7122 AF750-30-22 3/471SFL637025R6811 GAF750-10-11 3/1811SFL637025R6911 GAF750-10-11 3/1811SFL637025R7011 GAF750-10-11 3/1811SFL637025R7111 GAF750-10-11 3/1811SFL647001R6811 AF1250-30-11 3/351SFL647001R6822 AF1250-30-22 3/481SFL647001R6911 AF1250-30-11 3/351SFL647001R6922 AF1250-30-22 3/481SFL647001R7011 AF1250-30-11 3/351SFL647001R7022 AF1250-30-22 3/481SFL647001R7111 AF1250-30-11 3/351SFL647001R7122 AF1250-30-22 3/481SFL647025R6811 GAF1250-10-11 3/1821SFL647025R6911 GAF1250-10-11 3/1821SFL647025R7011 GAF1250-10-11 3/1821SFL647025R7111 GAF1250-10-11 3/1821SFL657001R7011 AF1350-30-11 3/351SFL657001R7022 AF1350-30-22 3/481SFL657001R9101 AF1350T-30-11 3/361SFL667001R7011 AF2650-30-11 3/351SFL667001R7022 AF2650-30-22 3/481SFL667001R9101 AF2650T-30-11 3/361SFL677001R7011 AF1650-30-11 3/351SFL677001R7022 AF1650-30-22 3/481SFL677001R9101 AF1650T-30-11 3/361SFL677025R7011 GAF1650-10-11 3/1821SFL687001R7011 AF2850-30-11 3/351SFL687001R7022 AF2850-30-22 3/481SFL687001R9101 AF2850T-30-11 3/361SFL707001R7011 AF2050-30-11 3/351SFL707001R7022 AF2050-30-22 3/481SFL707001R9101 AF2050T-30-11 3/361SFL707025R7011 GAF2050-10-11 3/1821SFN010716R1001 CEL18-01 3/2401SFN010716R1010 CEL18-10 3/2401SFN010720R1011 CAL18-11 3/2381SFN010720R3311 CAL18-11B 3/2381SFN010820R1011 CAL19-11 3/2381SFN010820R3311 CAL19-11B 3/2381SFN010832R1001 CEL19-01 3/2401SFN010832R1010 CEL19-10 3/2401SFN030300R1000 VM19 3/248 BER205-4 12/37 BER140-4 12/37 BER370-4 12/39 BEY140-4 12/85 BEY370-4 12/87 BEY205-4 12/871SFN034403R1000 VM140/190 3/248 BEY190-4 12/851SFN035203R1000 VM205/265 3/248 BEY265-4 12/871SFN035403R1000 VM370/400 3/2481SFN035700R1000 VM750H 3/2481SFN035701R1000 VM750V 3/2481SFN036503R1001 VM1650H 3/2481SFN074203R1000 LY140 3/2611SFN074207R1000 LW140 3/2601SFN074208R1000 LD146-30 3/2601SFN074208R2000 LD146-40 3/2601SFN074210R1000 LX140 3/2601SFN074211R1000 LL146-30 3/2601SFN074211R2000 LL146-40 3/2601SFN074307R1000 LW110 3/2921SFN074703R1000 LY185 3/2611SFN074712R1000 LP185 3/2611SFN074807R1000 LW205 3/2601SFN074807R2000 LW205-40 3/2601SFN074810R1000 LX205 3/2601SFN074811R1000 LL205-30 3/2601SFN074811R2000 LL205-40 3/2601SFN075103R1000 LY300 3/2611SFN075112R1000 LP300 3/2611SFN075407R1000 LW370 3/2601SFN075407R2000 LW370-40 3/2601SFN075410R1000 LX370 3/2601SFN075411R1000 LL370-30 3/2601SFN075411R2000 LL370-40 3/2601SFN075703R1000 LY460 3/2611SFN075707R1000 LW460 3/2601SFN075710R1000 LX460 3/2601SFN075712R1000 LP460 3/2611SFN075716R1000 LE460 3/2601SFN076103R1000 LY750 3/2611SFN076107R1000 LW750 3/2601SFN076110R1000 LX750 3/2601SFN076112R1000 LP750 3/2611SFN076116R1000 LE750 3/2601SFN076407R1000 LW1250 3/2601SFN076412R1000 LP1250 3/2941SFN076512R1000 LP2050 3/2941SFN084111R1000 BER140-4 12/371SFN084206R1000 BEA140/XT2 3/2651SFN084206R1001 BEA140/XT4 3/2651SFN084206R1002 BEA140/XT3 3/2651SFN084211R1000 BER140-4 3/2621SFN084214R1000 BEP140-30 3/2621SFN084214R2000 BEP140-40 3/2621SFN084413R1000 BEY140-4 3/2631SFN084806R1000 BEA205/XT4 3/2651SFN084806R1001 BEA205/T4 3/2651SFN084811R1000 BER205-4 3/2621SFN084813R1000 BEY190-4 3/2631SFN084814R1000 BEP205-30 3/2621SFN084814R2000 BEP205-40 3/2621SFN085213R1000 BEY205-4 3/2631SFN085406R1000 BEA370/T5 3/2651SFN085411R1000 BER370-4 3/2621SFN085413R1000 BEY265-4 3/2631SFN085414R1000 BEP370-30 3/2621SFN085414R2000 BEP370-40 3/2621SFN085701R1000 BEM460-30 3/2621SFN085703R1000 BED460 3/2631SFN085704R1000 BES460 3/2621SFN085708R1000 BEF460/OESA400 3/2651SFN085709R1000 OESA460H/OESA400 3/2651SFN085813R1000 BEY370-4 3/2631SFN085903R1000 BED580 3/2631SFN085907R1000 BEA460H/T4 3/2651SFN086101R1000 BEM750-30 3/2621SFN086103R1000 BED750 3/2631SFN086104R1000 BES750 3/2621SFN086106R1000 BEA750/T6 3/2651SFN086106R1001 BEA750/T5 3/2651SFN086106R1002 BEA750D/T6 3/2651SFN086106R1003 BEA750D/T5 3/2651SFN086108R1000 BEF750/OESA800 3/2651SFN094200R1000 PR146-1 3/2671SFN094900R1000 PR210-1 3/2671SFN095100R1001 PR185-2 3/2671SFN095300R1000 PR300-1 3/2671SFN095300R1001 PR300-2 3/2671SFN095700R1000 PR460-1 3/2671SFN095700R1001 PR460-2 3/2671SFN095700R1002 PR400-2 3/2671SFN095701R1000 PN460-21 3/2661SFN095703R1000 PN460-41 3/2661SFN095705R1000 PN460-11 3/2661SFN096100R1000 PR750-1 3/2671SFN096100R1001 PR750-2 3/2671SFN096100R1002 PR580-2 3/2671SFN096101R1000 PN750-21 3/2661SFN096103R1000 PN750-41 3/2661SFN096105R1000 PN750-11 3/2661SFN124203R1000 LT140-30L 3/2591SFN124203R2000 LT140-40L 3/2591SFN124801R1000 LT205-30C 3/2591SFN124801R2000 LT205-40C 3/2591SFN124803R1000 LT205-30L 3/2591SFN124803R2000 LT205-40L 3/2591SFN124804R1000 LT205-30Y 3/2591SFN125401R1000 LT370-30C 3/2591SFN125401R2000 LT370-40C 3/2591SFN125403R1000 LT370-30L 3/2591SFN125403R2000 LT370-40L 3/2591SFN125404R1000 LT370-30Y 3/2591SFN125406R1000 LT370-30D 3/2591SFN125701R1000 LT460-AC 3/2591SFN125703R1000 LT460-AL 3/2591SFN126101R1000 LT750-AC 3/2591SFN126103R1000 LT750-AL 3/2591SFN154310R8006 ZA110 3/2951SFN154310R8106 ZA110 3/29514
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/11ABB MOTOR PROTECTION AND CONTROL1SFN154310R8406 ZA110 3/2951SFN154310R8506 ZA110 3/2951SFN154310R8606 ZA110 3/2951SFN154310R8806 ZA110 3/2951SFN155770R6806 ZAF460 3/2691SFN155770R6906 ZAF460 3/2691SFN155770R7006 ZAF460 3/2691SFN155770R7106 ZAF460 3/2691SFN156170R6806 ZAF750 3/2691SFN156170R6906 ZAF750 3/2691SFN156170R7006 ZAF750 3/2691SFN156170R7106ZAF7503/2691SFN156570R7026 ZAF1650 3/2691SFN156670R7026 ZAF2650 3/2691SFN164302R1000 ZLU95 3/2951SFN164502R1000 ZLU110 3/2951SFN165703R1000 ZL400 3/2691SFN165710R1000 ZW460 3/2691SFN165903R1000 ZL460 3/2691SFN166103R1000 ZL580 3/2691SFN166110R1000 ZW750 3/2691SFN166303R1000 ZL750 3/2691SFN166403R1000 ZL1250 3/2691SFN166503R1000 ZL1350 3/2691SFN166503R1001 ZL1350-1 3/2691SFN166510R1001ZW16503/2691SFN166521R1070 ZP1650 3/2691SFN166603R1000 ZL2650 3/2691SFN166610R1000 ZW2650 3/2691SFN166621R1070 ZP2650 3/2691SFN166703R1000 ZL1650 3/2691SFN166703R1001 ZL1650-1 3/2691SFN167003R1000 ZL2050 3/2691SFN167003R1001 ZL2050-1 3/2691SFN170801R1001RU19/1203/2681SFN170801R1002 RU19/240 3/2681SNA235156R2700 BA4 3/2561SNA235712R2400 HTP500-BA4 3/2561SNA360010R1500 SPRC 1 3/2561SVR550800R9300 CM-MSE7/51SVR550801R9300 CM-MSE7/51SVR550805R9300 CM-MSE7/51SVR730100R0300 CT-ERS.21S 12/851SVR730210R3300 CT-SDS.22S 12/691SVR730211R2300 CT-SDS.23S 12/691SVR730700R0100 CM-MSS.12S7/51SVR730700R0200 CM-MSS.22S7/51SVR730700R2100 CM-MSS.13S7/51SVR730700R2200 CM-MSS.23S7/51SVR730712R0200 CM-MSS.32S7/51SVR730712R1200CM-MSS.41S7/51SVR730712R1300CM-MSS.51S7/51SVR730712R1400 CM-MSS.31S7/51SVR730712R2200 CM-MSS.33S7/51SVR730720R1400 CM-MSS.11S7/51SVR730722R1400 CM-MSS.21S7/51SVR740700R0100 CM-MSS.12P7/51SVR740700R0200 CM-MSS.22P7/51SVR740700R2100 CM-MSS.13P7/51SVR740700R2200 CM-MSS.23P7/51SVR740712R0200 CM-MSS.32P7/51SVR740712R1200CM-MSS.41P7/51SVR740712R1300CM-MSS.51P7/51SVR740712R1400 CM-MSS.31P7/51SVR740712R2200 CM-MSS.33P7/51SVR740720R1400 CM-MSS.11P7/51SVR740722R1400 CM-MSS.21P7/52CCS801901R0539 S801S-SCL32-SR 8/22CCS801901R0599 S801S-SCL63-SR 8/22CCS801901R0639 S801S-SCL100-SR 8/22CCS802901R0539 S802S-SCL32-SR 8/22CCS802901R0599 S802S-SCL63-SR 8/22CCS802901R0639 S802S-SCL100-SR 8/22CCS803901R0539 S803S-SCL32-SR 8/22CCS803901R0599 S803S-SCL63-SR 8/22CCS803901R0639 S803S-SCL100-SR 8/22CCS803917R0539 S803W-SCL32-SR 8/22CCS803917R0599 S803W-SCL63-SR 8/22CCS803917R0639 S803W-SCL100-SR 8/22CCS803901R0539 S803S-SCL32-SR 8/22CCS803901R0599 S803S-SCL63-SR 8/22CCS803901R0639 S803S-SCL100-SR 8/22CCS801901R0639 S801S-SCL100-SR 8/22CCS801901R0539 S801S-SCL32-SR 8/22CCS801901R0599 S801S-SCL63-SR 8/22CCS802901R0639 S802S-SCL100-SR 8/22CCS802901R0539 S802S-SCL32-SR 8/22CCS802901R0599 S802S-SCL63-SR 8/22CCS803917R0639 S803W-SCL100-SR 8/22CCS803917R0539 S803W-SCL32-SR 8/22CCS803917R0599 S803W-SCL63-SR 8/25223351-ANKWK10003/3055223351-ZKWK5503/305FPTN372726R1001 WB75-A 3/290FPTN372726R1002 WB75-A 3/290FPTN372726R1003 WB75-A 3/290FPTN372726R1004 WB75-A 3/290FPTN372726R1005 WB75-A 3/290FPTN372726R1006 WB75-A 3/290FPTN372726R1007 WB75-A 3/290FPTN372726R1008 WB75-A 3/290GHC0110003R0001 C011-70 7/6GHC0110003R0002 C011-80 7/6GHC0110003R0003 C011-90 7/6GHC0110003R0004 C011-100 7/6GHC0110003R0005 C011-110 7/6GHC0110003R0006 C011-120 7/6GHC0110003R0007 C011-130 7/6GHC0110003R0008 C011-150 7/6GHC0110003R0009 C011-160 7/6GHC0110003R0010 C011-170 7/6GHC0110003R0011 C011-140 7/6GHC0110033R0008 C011-3-150 7/6GHV2501902R0002 RV-BC6/60 4/49GHV2501903R0002 RV-BC6/250 4/49GJF1101903R0001 SA1 2/41GJF1101903R0002 SA2 2/41GJF1101903R0003 SA3 2/41GJH1211001R0221K6-22Z-014/17GJH1211001R0222K6-22Z-024/17GJH1211001R0223 K6-22Z-03 4/17GJH1211001R0311K6-31Z-014/17GJH1211001R0312K6-31Z-024/17GJH1211001R0313K6-31Z-034/17GJH1211001R0401 K6-40E-01 4/17GJH1211001R0402 K6-40E-02 4/17GJH1211001R0403 K6-40E-03 4/17GJH1211001R8220 K6-22Z-80 4/17GJH1211001R8224 K6-22Z-84 4/17GJH1211001R8225K6-22Z-854/17GJH1211001R8310K6-31Z-804/17GJH1211001R8314K6-31Z-844/17GJH1211001R8315K6-31Z-854/17GJH1211001R8400 K6-40E-80 4/17GJH1211001R8404 K6-40E-84 4/17GJH1211001R8405 K6-40E-85 4/17GJH1211003R0221K6-22Z-F-014/37GJH1211003R0222 K6-22Z-F-02 4/37GJH1211003R0223 K6-22Z-F-03 4/37GJH1211003R0311K6-31Z-F-014/37GJH1211003R0312K6-31Z-F-024/37GJH1211003R0313K6-31Z-F-034/37GJH1211003R0401 K6-40E-F-01 4/37GJH1211003R0402 K6-40E-F-02 4/37GJH1211003R0403 K6-40E-F-03 4/37GJH1211003R8220 K6-22Z-F-80 4/37GJH1211003R8224 K6-22Z-F-84 4/37GJH1211003R8225 K6-22Z-F-85 4/37GJH1211003R8310 K6-31Z-F-80 4/37GJH1211003R8314 K6-31Z-F-84 4/37GJH1211003R8315K6-31Z-F-854/37GJH1211003R8400 K6-40E-F-80 4/37GJH1211003R8404 K6-40E-F-84 4/37GJH1211003R8405 K6-40E-F-85 4/37GJH1211009R0221 K6-22Z-P-01 4/27GJH1211009R0222 K6-22Z-P-02 4/27GJH1211009R0223 K6-22Z-P-03 4/27GJH1211009R0311K6-31Z-P-014/27GJH1211009R0312 K6-31Z-P-02 4/27GJH1211009R0313 K6-31Z-P-03 4/27GJH1211009R0401 K6-40E-P-01 4/27GJH1211009R0402 K6-40E-P-02 4/27GJH1211009R0403 K6-40E-P-03 4/27GJH1211009R8220 K6-22Z-P-80 4/27GJH1211009R8224 K6-22Z-P-84 4/27GJH1211009R8225 K6-22Z-P-85 4/27GJH1211009R8310 K6-31Z-P-80 4/27GJH1211009R8314 K6-31Z-P-84 4/27GJH1211009R8315 K6-31Z-P-85 4/27GJH1211009R8400 K6-40E-P-80 4/27GJH1211009R8404 K6-40E-P-84 4/27GJH1211009R8405 K6-40E-P-85 4/27GJH1213001R0221 KC6-22Z-01 4/18GJH1213001R0223 KC6-22Z-03 4/18GJH1213001R0224 KC6-22Z-04 4/18GJH1213001R0225 KC6-22Z-05 4/18GJH1213001R0227 KC6-22Z-07 4/18GJH1213001R0311KC6-31Z-014/18GJH1213001R0313 KC6-31Z-03 4/18GJH1213001R0314 KC6-31Z-04 4/18GJH1213001R0315 KC6-31Z-05 4/18GJH1213001R0317KC6-31Z-074/18GJH1213001R0401 KC6-40E-01 4/18GJH1213001R0403 KC6-40E-03 4/18GJH1213001R0404 KC6-40E-04 4/18GJH1213001R0405 KC6-40E-05 4/18GJH1213001R0407 KC6-40E-07 4/18GJH1213001R1226 KC6-22Z-16 4/18GJH1213001R1316KC6-31Z-164/18GJH1213001R1406 KC6-40E-16 4/18GJH1213001R5311KC6-31Z-2.4-514/19GJH1213001R5401 KC6-40E-2.4-51 4/19GJH1213001R7221K6S-22Z-1.7-714/19GJH1213001R7222K6S-22Z-2.8-724/19GJH1213001R7311K6S-31Z-1.7-714/19GJH1213001R7312K6S-31Z-2.8-724/19GJH1213001R7401 K6S-40E-1.7-71 4/19GJH1213001R7402 K6S-40E-2.8-72 4/19GJH1213001R8311KC6-31Z-1.4-814/19GJH1213001R8401 KC6-40E-1.4-81 4/19GJH1213003R0221 KC6-22Z-F-01 4/3814
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage ABB MOTOR PROTECTION AND CONTROL 14/12GJH1213003R0224 KC6-22Z-F-04 4/38GJH1213003R0225 KC6-22Z-F-05 4/38GJH1213003R0227 KC6-22Z-F-07 4/38GJH1213003R0311 KC6-31Z-F-01 4/38GJH1213003R0314 KC6-31Z-F-04 4/38GJH1213003R0315 KC6-31Z-F-05 4/38GJH1213003R0317 KC6-31Z-F-07 4/38GJH1213003R0401 KC6-40E-F-01 4/38GJH1213003R0404 KC6-40E-F-04 4/38GJH1213003R0405 KC6-40E-F-05 4/38GJH1213003R1226 KC6-22Z-F-16 4/38GJH1213003R1316 KC6-31Z-F-16 4/38GJH1213003R1406 KC6-40E-F-16 4/38GJH1213003R5311 KC6-31Z-F-51 4/39GJH1213003R5401 KC6-40E-F-51 4/39GJH1213003R8311 KC6-31Z-F-1.4-81 4/39GJH1213003R8401 KC6-40E-F-1.4-81 4/39GJH1213009R0221 KC6-22Z-P-01 4/28GJH1213009R0224 KC6-22Z-P-04 4/28GJH1213009R0225 KC6-22Z-P-05 4/28GJH1213009R0227 KC6-22Z-P-07 4/28GJH1213009R0311 KC6-31Z-P-01 4/28GJH1213009R0314 KC6-31Z-P-04 4/28GJH1213009R0315 KC6-31Z-P-05 4/28GJH1213009R0401 KC6-40E-P-01 4/28GJH1213009R0404 KC6-40E-P-04 4/28GJH1213009R0405 KC6-40E-P-05 4/28GJH1213009R0407 KC6-40E-P-07 4/28GJH1213009R1226 KC6-22Z-P-16 4/28GJH1213009R1316 KC6-31Z-P-16 4/28GJH1213009R1406 KC6-40E-P-16 4/28GJH1213009R5311 KC6-31Z-P-2.4-51 4/29GJH1213009R5401 KC6-40E-P-2.4-51 4/29GJH1213009R8311 KC6-31Z-P-1.4-81 4/29GJH1213009R8401 KC6-40E-P-1.4-81 4/29GJL1201317R0001 CA6-11K 4/50GJL1201317R0002 CA6-11E 4/49GJL1201317R0003 CA6-11M 4/49GJL1201317R0004 CA6-11N 4/49GJL1201318R0001 CA6-11K-F 4/50GJL1201318R0002 CA6-11E-F 4/49GJL1201318R0003 CA6-11M-F 4/49GJL1201318R0004 CA6-11N-F 4/49GJL1201319R0001 CA6-11K-P 4/50GJL1201319R0002 CA6-11E-P 4/49GJL1201319R0003 CA6-11M-P 4/49GJL1201319R0004 CA6-11N-P 4/49GJL1201330R0001 CAF6-11K 4/50GJL1201330R0002 CAF6-11E 4/49GJL1201330R0003 CAF6-11M 4/49GJL1201330R0004 CAF6-11N 4/49GJL1201330R0005 CAF6-20K 4/50GJL1201330R0006 CAF6-20E 4/49GJL1201330R0007 CAF6-20M 4/49GJL1201330R0008 CAF6-20N 4/49GJL1201330R0009 CAF6-02K 4/50GJL1201330R0010 CAF6-02E 4/49GJL1201330R0011 CAF6-02M 4/49GJL1201330R0012 CAF6-02N 4/49GJL1201902R0001 LB6 4/49GJL1201903R0001 LB6-CA 4/49GJL1201906R0001 LT6-B 4/49GJL1201907R0001 LP6 4/49GJL1201908R0001 BSM6-30 4/49GJL1211001R0011 B6-30-01-01 4/8GJL1211001R0012 B6-30-01-02 4/8GJL1211001R0013 B6-30-01-03 4/8GJL1211001R0101 B6-30-10-01 4/8GJL1211001R0102 B6-30-10-02 4/8GJL1211001R0103 B6-30-10-03 4/8GJL1211001R8010 B6-30-01-80 4/8GJL1211001R8014 B6-30-01-84 4/8GJL1211001R8015 B6-30-01-85 4/8GJL1211001R8100 B6-30-10-80 4/8GJL1211001R8104 B6-30-10-84 4/8GJL1211001R8105 B6-30-10-85 4/8GJL1211003R0011 B6-30-01-F-01 4/30GJL1211003R0012 B6-30-01-F-02 4/30GJL1211003R0013 B6-30-01-F-03 4/30GJL1211003R0101 B6-30-10-F-01 4/30GJL1211003R0102 B6-30-10-F-02 4/30GJL1211003R0103 B6-30-10-F-03 4/30GJL1211003R8010 B6-30-01-F-80 4/30GJL1211003R8014 B6-30-01-F-84 4/30GJL1211003R8015 B6-30-01-F-85 4/30GJL1211003R8100 B6-30-10-F-80 4/30GJL1211003R8104 B6-30-10-F-84 4/30GJL1211003R8105 B6-30-10-F-85 4/30GJL1211009R0011 B6-30-01-P-01 4/20GJL1211009R0012 B6-30-01-P-02 4/20GJL1211009R0013 B6-30-01-P-03 4/20GJL1211009R0101 B6-30-10-P-01 4/20GJL1211009R0102 B6-30-10-P-02 4/20GJL1211009R0103 B6-30-10-P-03 4/20GJL1211009R8010 B6-30-01-P-80 4/20GJL1211009R8014 B6-30-01-P-84 4/20GJL1211009R8015 B6-30-01-P-85 4/20GJL1211009R8100 B6-30-10-P-80 4/20GJL1211009R8104 B6-30-10-P-84 4/20GJL1211009R8105 B6-30-10-P-85 4/20GJL1211201R0001 B6-40-00-01 4/15GJL1211201R0002 B6-40-00-02 4/15GJL1211201R0003 B6-40-00-03 4/15GJL1211201R8000 B6-40-00-80 4/15GJL1211201R8004 B6-40-00-84 4/15GJL1211501R0001 B6-22-00-01 4/15GJL1211501R0002 B6-22-00-02 4/15GJL1211501R0003 B6-22-00-03 4/15GJL1211501R8000 B6-22-00-80 4/15GJL1211501R8004 B6-22-00-84 4/15GJL1211901R0011 VB6-30-01-01 4/10GJL1211901R0012 VB6-30-01-02 4/10GJL1211901R0013 VB6-30-01-03 4/10GJL1211901R0101 VB6-30-10-01 4/10GJL1211901R0102 VB6-30-10-02 4/10GJL1211901R0103 VB6-30-10-03 4/10GJL1211901R8010 VB6-30-01-80 4/10GJL1211901R8014 VB6-30-01-84 4/10GJL1211901R8015 VB6-30-01-85 4/10GJL1211901R8100 VB6-30-10-80 4/10GJL1211901R8104 VB6-30-10-84 4/10GJL1211901R8105 VB6-30-10-85 4/10GJL1211909R0011 VB6-30-01-P-01 4/22GJL1211909R0012 VB6-30-01-P-02 4/22GJL1211909R0013 VB6-30-01-P-03 4/22GJL1211909R0101 VB6-30-10-P-01 4/22GJL1211909R0102 VB6-30-10-P-02 4/22GJL1211909R0103 VB6-30-10-P-03 4/22GJL1211909R8010 VB6-30-01-P-80 4/22GJL1211909R8014 VB6-30-01-P-84 4/22GJL1211909R8015 VB6-30-01-P-85 4/22GJL1211909R8100 VB6-30-10-P-80 4/22GJL1211909R8104 VB6-30-10-P-84 4/22GJL1211909R8105 VB6-30-10-P-85 4/22GJL1211911R0011 VB6A-30-01-01 4/12GJL1211911R0012 VB6A-30-01-02 4/12GJL1211911R0013 VB6A-30-01-03 4/12GJL1211911R0101 VB6A-30-10-01 4/12GJL1211911R0102 VB6A-30-10-02 4/12GJL1211911R0103 VB6A-30-10-03 4/12GJL1211911R8010 VB6A-30-01-80 4/12GJL1211911R8014 VB6A-30-01-84 4/12GJL1211911R8015 VB6A-30-01-85 4/12GJL1211911R8100 VB6A-30-10-80 4/12GJL1211911R8104 VB6A-30-10-84 4/12GJL1211911R8105 VB6A-30-10-85 4/12GJL1211919R0011 VB6A-30-01-P-01 4/24GJL1211919R0012 VB6A-30-01-P-02 4/24GJL1211919R0013 VB6A-30-01-P-03 4/24GJL1211919R0101 VB6A-30-10-P-01 4/24GJL1211919R0102 VB6A-30-10-P-02 4/24GJL1211919R0103 VB6A-30-10-P-03 4/24GJL1211919R8010 VB6A-30-01-P-80 4/24GJL1211919R8014 VB6A-30-01-P-84 4/24GJL1211919R8015 VB6A-30-01-P-85 4/24GJL1211919R8100 VB6A-30-10-P-80 4/24GJL1211919R8104 VB6A-30-10-P-84 4/24GJL1211919R8105 VB6A-30-10-P-85 4/24GJL1213001R0011 BC6-30-01-01 4/9GJL1213001R0013 BC6-30-01-03 4/9GJL1213001R0014 BC6-30-01-04 4/9GJL1213001R0015 BC6-30-01-05 4/9GJL1213001R0017 BC6-30-01-07 4/9GJL1213001R0101 BC6-30-10-01 4/9GJL1213001R0103 BC6-30-10-03 4/9GJL1213001R0104 BC6-30-10-04 4/9GJL1213001R0105 BC6-30-10-05 4/9GJL1213001R0107 BC6-30-10-07 4/9GJL1213001R1016 BC6-30-01-16 4/9GJL1213001R1106 BC6-30-10-16 4/9GJL1213001R5011 BC6-30-01-2.4-51 4/14GJL1213001R5101 BC6-30-10-2.4-51 4/14GJL1213001R7011 B6S-30-01-1.7-71 4/14GJL1213001R7012 B6S-30-01-2.8-72 4/14GJL1213001R7101 B6S-30-10-1.7-71 4/14GJL1213001R7102 B6S-30-10-2.8-72 4/14GJL1213001R8011 BC6-30-01-1.4-81 4/14GJL1213001R8101 BC6-30-10-1.4-81 4/14GJL1213003R0011 BC6-30-01-F-01 4/31GJL1213003R0013 BC6-30-01-F-03 4/31GJL1213003R0014 BC6-30-01-F-04 4/31GJL1213003R0015 BC6-30-01-F-05 4/31GJL1213003R0017 BC6-30-01-F-07 4/31GJL1213003R0101 BC6-30-10-F-01 4/31GJL1213003R0103 BC6-30-10-F-03 4/31GJL1213003R0104 BC6-30-10-F-04 4/31GJL1213003R0105 BC6-30-10-F-05 4/31GJL1213003R0107 BC6-30-10-F-07 4/31GJL1213003R1016 BC6-30-01-F-16 4/31GJL1213003R1106 BC6-30-10-F-16 4/31GJL1213003R5011 BC6-30-01-F-2.4-51 4/36GJL1213003R5101 BC6-30-10-F-2.4-51 4/36GJL1213003R8011 BC6-30-01-F-1.4-81 4/36GJL1213003R8101 BC6-30-10-F-1.4-81 4/36GJL1213009R0011 BC6-30-01-P-01 4/21GJL1213009R0013 BC6-30-01-P-03 4/21GJL1213009R0014 BC6-30-01-P-04 4/21GJL1213009R0015 BC6-30-01-P-05 4/21GJL1213009R0017 BC6-30-01-P-07 4/21GJL1213009R0101 BC6-30-10-P-01 4/21GJL1213009R0103 BC6-30-10-P-03 4/2114
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage14/13 ABB MOTOR PROTECTION AND CONTROLGJL1213009R0104 BC6-30-10-P-04 4/21GJL1213009R0105 BC6-30-10-P-05 4/21GJL1213009R0107 BC6-30-10-P-07 4/21GJL1213009R1016 BC6-30-01-P-16 4/21GJL1213009R1106 BC6-30-10-P-16 4/21GJL1213009R5011 BC6-30-01-P-2.4-51 4/26GJL1213009R5101 BC6-30-10-P-2.4-51 4/26GJL1213009R8011 BC6-30-01-P-1.4-81 4/26GJL1213009R8101 BC6-30-10-P-1.4-81 4/26GJL1213109R0101 BC6-21-10-P-01 4/21GJL1213109R0103 BC6-21-10-P-03 4/21GJL1213109R0104 BC6-21-10-P-04 4/21GJL1213109R0105 BC6-21-10-P-05 4/21GJL1213109R1106 BC6-21-10-P-16 4/21GJL1213501R0001 BC6-22-00-01 4/16GJL1213501R0002 BC6-22-00-02 4/16GJL1213501R0003 BC6-22-00-03 4/16GJL1213501R0004 BC6-22-00-04 4/16GJL1213501R0005 BC6-22-00-05 4/16GJL1213501R0007 BC6-22-00-07 4/16GJL1213501R1006 BC6-22-00-16 4/16GJL1213901R0011 VBC6-30-01-01 4/11GJL1213901R0013 VBC6-30-01-03 4/11GJL1213901R0014 VBC6-30-01-04 4/11GJL1213901R0015 VBC6-30-01-05 4/11GJL1213901R0017 VBC6-30-01-07 4/11GJL1213901R0101 VBC6-30-10-01 4/11GJL1213901R0103 VBC6-30-10-03 4/11GJL1213901R0104 VBC6-30-10-04 4/11GJL1213901R0105 VBC6-30-10-05 4/11GJL1213901R0107 VBC6-30-10-07 4/11GJL1213901R1016 VBC6-30-01-16 4/11GJL1213901R1106 VBC6-30-10-16 4/11GJL1213909R0011 VBC6-30-01-P-01 4/23GJL1213909R0013 VBC6-30-01-P-03 4/23GJL1213909R0014 VBC6-30-01-P-04 4/23GJL1213909R0015 VBC6-30-01-P-05 4/23GJL1213909R0016 VBC6-30-06-P-06 4/23GJL1213909R0017 VBC6-30-01-P-07 4/23GJL1213909R0101 VBC6-30-10-P-01 4/23GJL1213909R0103 VBC6-30-10-P-03 4/23GJL1213909R0104 VBC6-30-10-P-04 4/23GJL1213909R0105 VBC6-30-10-P-05 4/23GJL1213909R0106 VBC6-30-10-P-06 4/23GJL1213909R0107 VBC6-30-10-P-07 4/23GJL1213911R0011 VBC6A-30-01-01 4/13GJL1213911R0013 VBC6A-30-01-03 4/13GJL1213911R0014 VBC6A-30-01-04 4/13GJL1213911R0015 VBC6A-30-01-05 4/13GJL1213911R0017 VBC6A-30-01-07 4/13GJL1213911R0101 VBC6A-30-10-01 4/13GJL1213911R0103 VBC6A-30-10-03 4/13GJL1213911R0104 VBC6A-30-10-04 4/13GJL1213911R0105 VBC6A-30-10-05 4/13GJL1213911R0107 VBC6A-30-10-07 4/13GJL1213911R1016 VBC6A-30-01-16 4/13GJL1213911R1106 VBC6A-30-10-16 4/13GJL1311001R0011 B7-30-01-01 4/8GJL1311001R0012 B7-30-01-02 4/8GJL1311001R0013 B7-30-01-03 4/8GJL1311001R0101 B7-30-10-01 4/8GJL1311001R0102 B7-30-10-02 4/8GJL1311001R0103 B7-30-10-03 4/8GJL1311001R8010 B7-30-01-80 4/8GJL1311001R8014 B7-30-01-84 4/8GJL1311001R8015 B7-30-01-85 4/8GJL1311001R8100 B7-30-10-80 4/8GJL1311001R8104 B7-30-10-84 4/8GJL1311001R8105 B7-30-10-85 4/8GJL1311003R0011 B7-30-01-F-01 4/30GJL1311003R0012 B7-30-01-F-02 4/30GJL1311003R0013 B7-30-01-F-03 4/30GJL1311003R0101 B7-30-10-F-01 4/30GJL1311003R0102 B7-30-10-F-02 4/30GJL1311003R0103 B7-30-10-F-03 4/30GJL1311003R8010 B7-30-01-F-80 4/30GJL1311003R8014 B7-30-01-F-84 4/30GJL1311003R8015 B7-30-01-F-85 4/30GJL1311003R8100 B7-30-10-F-80 4/30GJL1311003R8104 B7-30-10-F-84 4/30GJL1311003R8105 B7-30-10-F-85 4/30GJL1311009R0011 B7-30-01-P-01 4/20GJL1311009R0012 B7-30-01-P-02 4/20GJL1311009R0013 B7-30-01-P-03 4/20GJL1311009R0101 B7-30-10-P-01 4/20GJL1311009R0102 B7-30-10-P-02 4/20GJL1311009R0103 B7-30-10-P-03 4/20GJL1311009R8010 B7-30-01-P-80 4/20GJL1311009R8014 B7-30-01-P-84 4/20GJL1311009R8015 B7-30-01-P-85 4/20GJL1311009R8100 B7-30-10-P-80 4/20GJL1311009R8104 B7-30-10-P-84 4/20GJL1311009R8105 B7-30-10-P-85 4/20GJL1311201R0001 B7-40-00-01 4/15GJL1311201R0002 B7-40-00-02 4/15GJL1311201R0003 B7-40-00-03 4/15GJL1311201R8000 B7-40-00-80 4/15GJL1311201R8004 B7-40-00-84 4/15GJL1311501R0001 B7-22-00-01 4/15GJL1311501R0002 B7-22-00-02 4/15GJL1311501R0003 B7-22-00-03 4/15GJL1311501R8000 B7-22-00-80 4/15GJL1311501R8004 B7-22-00-84 4/15GJL1311901R0011 VB7-30-01-01 4/10GJL1311901R0012 VB7-30-01-02 4/10GJL1311901R0013 VB7-30-01-03 4/10GJL1311901R0101 VB7-30-10-01 4/10GJL1311901R0102 VB7-30-10-02 4/10GJL1311901R0103 VB7-30-10-03 4/10GJL1311901R8010 VB7-30-01-80 4/10GJL1311901R8014 VB7-30-01-84 4/10GJL1311901R8015 VB7-30-01-85 4/10GJL1311901R8100 VB7-30-10-80 4/10GJL1311901R8104 VB7-30-10-84 4/10GJL1311901R8105 VB7-30-10-85 4/10GJL1311903R0011 VB7-30-01-F-01 4/32GJL1311903R0012 VB7-30-01-F-02 4/32GJL1311903R0013 VB7-30-01-F-03 4/32GJL1311903R0101 VB7-30-10-F-01 4/32GJL1311903R0102 VB7-30-10-F-02 4/32GJL1311903R0103 VB7-30-10-F-03 4/32GJL1311903R8010 VB7-30-01-F-80 4/32GJL1311903R8014 VB7-30-01-F-84 4/32GJL1311903R8015 VB7-30-01-F-85 4/32GJL1311903R8100 VB7-30-10-F-80 4/32GJL1311903R8104 VB7-30-10-F-84 4/32GJL1311903R8105 VB7-30-10-F-85 4/32GJL1311909R0011 VB7-30-01-P-01 4/22GJL1311909R0012 VB7-30-01-P-02 4/22GJL1311909R0013 VB7-30-01-P-03 4/22GJL1311909R0101 VB7-30-10-P-01 4/22GJL1311909R0102 VB7-30-10-P-02 4/22GJL1311909R0103 VB7-30-10-P-03 4/22GJL1311909R8010 VB7-30-01-P-80 4/22GJL1311909R8014 VB7-30-01-P-84 4/22GJL1311909R8015 VB7-30-01-P-85 4/22GJL1311909R8100 VB7-30-10-P-80 4/22GJL1311909R8104 VB7-30-10-P-84 4/22GJL1311909R8105 VB7-30-10-P-85 4/22GJL1311911R0011 VB7A-30-01-01 4/12GJL1311911R0012 VB7A-30-01-02 4/12GJL1311911R0013 VB7A-30-01-03 4/12GJL1311911R0101 VB7A-30-10-01 4/12GJL1311911R0102 VB7A-30-10-02 4/12GJL1311911R0103 VB7A-30-10-03 4/12GJL1311911R8010 VB7A-30-01-80 4/12GJL1311911R8014 VB7A-30-01-84 4/12GJL1311911R8015 VB7A-30-01-85 4/12GJL1311911R8100 VB7A-30-10-80 4/12GJL1311911R8104 VB7A-30-10-84 4/12GJL1311911R8105 VB7A-30-10-85 4/12GJL1311913R0011 VB7A-30-01-F-01 4/34GJL1311913R0012 VB7A-30-01-F-02 4/34GJL1311913R0013 VB7A-30-01-F-03 4/34GJL1311913R0101 VB7A-30-10-F-01 4/34GJL1311913R0102 VB7A-30-10-F-02 4/34GJL1311913R0103 VB7A-30-10-F-03 4/34GJL1311913R8010 VB7A-30-01-F-80 4/34GJL1311913R8014 VB7A-30-01-F-84 4/34GJL1311913R8015 VB7A-30-01-F-85 4/34GJL1311913R8100 VB7A-30-10-F-80 4/34GJL1311913R8104 VB7A-30-10-F-84 4/34GJL1311913R8105 VB7A-30-10-F-85 4/34GJL1311919R0011 VB7A-30-01-P-01 4/24GJL1311919R0012 VB7A-30-01-P-02 4/24GJL1311919R0013 VB7A-30-01-P-03 4/24GJL1311919R0101 VB7A-30-10-P-01 4/24GJL1311919R0102 VB7A-30-10-P-02 4/24GJL1311919R0103 VB7A-30-10-P-03 4/24GJL1311919R8010 VB7A-30-01-P-80 4/24GJL1311919R8014 VB7A-30-01-P-84 4/24GJL1311919R8015 VB7A-30-01-P-85 4/24GJL1311919R8100 VB7A-30-10-P-80 4/24GJL1311919R8104 VB7A-30-10-P-84 4/24GJL1311919R8105 VB7A-30-10-P-85 4/24GJL1313001R0011 BC7-30-01-01 4/9GJL1313001R0013 BC7-30-01-03 4/9GJL1313001R0014 BC7-30-01-04 4/9GJL1313001R0015 BC7-30-01-05 4/9GJL1313001R0017 BC7-30-01-07 4/9GJL1313001R0101 BC7-30-10-01 4/9GJL1313001R0104 BC7-30-10-04 4/9GJL1313001R0105 BC7-30-10-05 4/9GJL1313001R0107 BC7-30-10-07 4/9GJL1313001R1016 BC7-30-01-16 4/9GJL1313001R1103 BC7-30-10-03 4/9GJL1313001R1106 BC7-30-10-16 4/9GJL1313001R5011 BC7-30-01-2.4-51 4/14GJL1313001R5101 BC7-30-10-2.4-51 4/14GJL1313001R7011 B7S-30-01-1.7-71 4/14GJL1313001R7012 B7S-30-01-2.8-72 4/14GJL1313001R7101 B7S-30-10-1.7-71 4/14GJL1313001R7102 B7S-30-10-2.8-72 4/14GJL1313001R8011 BC7-30-01-1.4-81 4/14GJL1313001R8101 BC7-30-10-1.4-81 4/14GJL1313003R0011 BC7-30-01-F-01 4/31GJL1313003R0013 BC7-30-01-F-03 4/31GJL1313003R0014 BC7-30-01-F-04 4/31GJL1313003R0015 BC7-30-01-F-05 4/31GJL1313003R0017 BC7-30-01-F-07 4/31GJL1313003R0101 BC7-30-10-F-01 4/3114
—IndexOrder code classificationOrder codeTypePageOrder codeTypePageOrder codeTypePage ABB MOTOR PROTECTION AND CONTROL 14/14GJL1313003R0103 BC7-30-10-F-03 4/31GJL1313003R0104 BC7-30-10-F-04 4/31GJL1313003R0105 BC7-30-10-F-05 4/31GJL1313003R0107 BC7-30-10-F-07 4/31GJL1313003R1016 BC7-30-01-F-16 4/31GJL1313003R1106 BC7-30-10-F-16 4/31GJL1313003R5011 BC7-30-01-F-2.4-51 4/36GJL1313003R5101 BC7-30-10-F-2.4-51 4/36GJL1313003R8011 BC7-30-01-F-1.4-81 4/36GJL1313003R8101 BC7-30-10-F-1.4-81 4/36GJL1313009R0011 BC7-30-01-P-01 4/21GJL1313009R0013 BC7-30-01-P-03 4/21GJL1313009R0014 BC7-30-01-P-04 4/21GJL1313009R0015 BC7-30-01-P-05 4/21GJL1313009R0017 BC7-30-01-P-07 4/21GJL1313009R0101 BC7-30-10-P-01 4/21GJL1313009R0103 BC7-30-10-P-03 4/21GJL1313009R0104 BC7-30-10-P-04 4/21GJL1313009R0105 BC7-30-10-P-05 4/21GJL1313009R0107 BC7-30-10-P-07 4/21GJL1313009R1016 BC7-30-01-P-16 4/21GJL1313009R1106 BC7-30-10-P-16 4/21GJL1313009R5011 BC7-30-01-P-2.4-51 4/26GJL1313009R5101 BC7-30-10-P-2.4-51 4/26GJL1313009R8011 BC7-30-01-P-1.4-81 4/26GJL1313009R8101 BC7-30-10-P-1.4-81 4/26GJL1313901R0011 VBC7-30-01-01 4/11GJL1313901R0013 VBC7-30-01-03 4/11GJL1313901R0014 VBC7-30-01-04 4/11GJL1313901R0015 VBC7-30-01-05 4/11GJL1313901R0017 VBC7-30-01-07 4/11GJL1313901R0101 VBC7-30-10-01 4/11GJL1313901R0103 VBC7-30-10-03 4/11GJL1313901R0104 VBC7-30-10-04 4/11GJL1313901R0105 VBC7-30-10-05 4/11GJL1313901R0107 VBC7-30-10-07 4/11GJL1313901R1016 VBC7-30-01-16 4/11GJL1313901R1106 VBC7-30-10-16 4/11GJL1313903R0011 VBC7-30-01-F-01 4/33GJL1313903R0013 VBC7-30-01-F-03 4/33GJL1313903R0014 VBC7-30-01-F-04 4/33GJL1313903R0015 VBC7-30-01-F-05 4/33GJL1313903R0017 VBC7-30-01-F-07 4/33GJL1313903R0101 VBC7-30-10-F-01 4/33GJL1313903R0103 VBC7-30-10-F-03 4/33GJL1313903R0104 VBC7-30-10-F-04 4/33GJL1313903R0105 VBC7-30-10-F-05 4/33GJL1313903R0107 VBC7-30-10-F-07 4/33GJL1313903R1016 VBC7-30-01-F-16 4/33GJL1313903R1106 VBC7-30-10-F-16 4/33GJL1313909R0011 VBC7-30-01-P-01 4/23GJL1313909R0013 VBC7-30-01-P-03 4/23GJL1313909R0014 VBC7-30-01-P-04 4/23GJL1313909R0015 VBC7-30-01-P-05 4/23GJL1313909R0017 VBC7-30-01-P-07 4/23GJL1313909R0101 VBC7-30-10-P-01 4/23GJL1313909R0103 VBC7-30-10-P-03 4/23GJL1313909R0104 VBC7-30-10-P-04 4/23GJL1313909R0105 VBC7-30-10-P-05 4/23GJL1313909R0107 VBC7-30-10-P-07 4/23GJL1313909R1016 VBC7-30-01-P-16 4/23GJL1313909R1106 VBC7-30-10-P-16 4/23GJL1313911R0011 VBC7A-30-01-01 4/13GJL1313911R0013 VBC7A-30-01-03 4/13GJL1313911R0014 VBC7A-30-01-04 4/13GJL1313911R0015 VBC7A-30-01-05 4/13GJL1313911R0016 VBC7A-30-01-16 4/13GJL1313911R0017 VBC7A-30-01-07 4/13GJL1313911R0101 VBC7A-30-10-01 4/13GJL1313911R0103 VBC7A-30-10-03 4/13GJL1313911R0104 VBC7A-30-10-04 4/13GJL1313911R0105 VBC7A-30-10-05 4/13GJL1313911R0107 VBC7A-30-10-07 4/13GJL1313911R1106 VBC7A-30-10-16 4/13GJL1313913R0011 VBC7A-30-01-F-01 4/35GJL1313913R0013 VBC7A-30-01-F-03 4/35GJL1313913R0014 VBC7A-30-01-F-04 4/35GJL1313913R0015 VBC7A-30-01-F-05 4/35GJL1313913R0017 VBC7A-30-01-F-07 4/35GJL1313913R0101 VBC7A-30-10-F-01 4/35GJL1313913R0103 VBC7A-30-10-F-03 4/35GJL1313913R0104 VBC7A-30-10-F-04 4/35GJL1313913R0105 VBC7A-30-10-F-05 4/35GJL1313913R0107 VBC7A-30-10-F-07 4/35GJL1313913R1016 VBC7A-30-01-F-16 4/35GJL1313913R1106 VBC7A-30-10-F-16 4/35GJL1313919R0011 VBC7A-30-01-P-01 4/25GJL1313919R0013 VBC7A-30-01-P-03 4/25GJL1313919R0014 VBC7A-30-01-P-04 4/25GJL1313919R0015 VBC7A-30-01-P-05 4/25GJL1313919R0017 VBC7A-30-01-P-07 4/25GJL1313919R0101 VBC7A-30-10-P-01 4/25GJL1313919R0103 VBC7A-30-10-P-03 4/25GJL1313919R0104 VBC7A-30-10-P-04 4/25GJL1313919R0105 VBC7A-30-10-P-05 4/25GJL1313919R0107 VBC7A-30-10-P-07 4/25GJL1313919R1016 VBC7A-30-01-P-16 4/25GJL1313919R1106 VBC7A-30-10-P-16 4/25GJL1317001R0011 B7D-30-01-01 4/9GJL1317001R0015 B7D-30-01-05 4/9GJL1317001R0101 B7D-30-10-01 4/9GJL1317001R0105 B7D-30-10-05 4/9GJL1317201R0001 B7D-40-00-01 4/16GJL1317201R0005 B7D-40-00-05 4/16SK178001-LB LT550-EK 3/302SK178001-MB LT1000-EK 3/302SK827041-AD EK550-40-11 3/148SK827041-AR EK550-40-11 3/148SK827041-DB EK550-40-21 3/149SK827041-DD EK550-40-21 3/149SK827041-DE EK550-40-21 3/149SK827041-DF EK550-40-21 3/149SK827041-DG EK550-40-21 3/149SK827041-DU EK550-40-21 3/149SK827041-EF EK550-40-11 3/148SK827041-EG EK550-40-11 3/148SK827041-EL EK550-40-11 3/148SK827041-EM EK550-40-11 3/148SK827043-AD EK550-40-22 3/150SK827043-AR EK550-40-22 3/150SK827043-EF EK550-40-22 3/150SK827043-EG EK550-40-22 3/150SK827043-EL EK550-40-22 3/150SK827043-EM EK550-40-22 3/150SK827044-AD EK1000-40-11 3/148SK827044-AR EK1000-40-11 3/148SK827044-DB EK1000-40-21 3/149SK827044-DC EK1000-40-21 3/149SK827044-DD EK1000-40-21 3/149SK827044-DE EK1000-40-21 3/149SK827044-DF EK1000-40-21 3/149SK827044-DG EK1000-40-21 3/149SK827044-DT EK1000-40-21 3/149SK827044-DU EK1000-40-21 3/149SK827044-EF EK1000-40-11 3/148SK827044-EG EK1000-40-11 3/148SK827044-EL EK1000-40-11 3/148SK827044-EM EK1000-40-11 3/148SK827045-AD EK1000-40-22 3/150SK827045-AR EK1000-40-22 3/150SK827045-EF EK1000-40-22 3/150SK827045-EG EK1000-40-22 3/150SK827045-EL EK1000-40-22 3/150SK827045-EM EK1000-40-22 3/150SK827045-EP EK1000-40-22 3/150SK827045-ER EK1000-40-22 3/150SK827204-B KZK550 3/305SK827204-F KZK1000 3/305SK828100-AD KH800 3/306SK828100-AR KH800 3/306SK828100-EF KH800 3/306SK828100-EG KH800 3/306SK828100-EL KH800 3/306SK828100-EM KH800 3/306SK828100-ER KH800 3/306SK828150-DB KP800 3/306SK828150-DE KP800 3/306SK828150-DF KP800 3/306SK828150-DU KP800 3/306SK829002-A CAL16-11A 3/298SK829002-B CAL16-11B 3/152SK829002-C CAL16-11C 3/152SK829002-D CAL16-11D 3/152SK829002-E CCL16-11E 3/152 SK829007-C RC-EH800/110 3/152SK829007-D RC-EH800/600 3/152SK829070-F VH800 3/152SK829090-E BSS550 3/152SK829090-H BSS1000 3/1521SDA054988R1 1SDA055020R1 3/701SDA066917R1 1SDA055016R1 3/701SFN074709R1000, 1SCA022194R0890 3/1632CCS801901R0539 412012 8/22CCS801901R0599 412036 8/22CCS801901R0639 411992 8/22CCS802901R0539 412074 8/22CCS802901R0599 412098 8/22CCS802901R0639 412050 8/22CCS803901R0539 411930 8/22CCS803901R0599 411947 8/22CCS803901R0639 411954 8/22CCS803917R0539 412319 8/22CCS803917R0599 412326 8/22CCS803917R0639 412302 8/214
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/15ABB MOTOR PROTECTION AND CONTROLAA1-1101SAM201910R1002 2/36AA1-2301SAM201910R1003 2/36AA1-241SAM201910R1001 2/36AA1-4001SAM201910R1004 2/36AF09-22-00-111SBL137501R1100 3/134AF09-22-00-121SBL137501R1200 3/134AF09-22-00-131SBL137501R1300 3/134AF09-22-00-141SBL137501R1400 3/134AF09-30-01-111SBL137001R11013/14AF09-30-01-121SBL137001R12013/14AF09-30-01-131SBL137001R13013/14AF09-30-01-141SBL137001R14013/14AF09-30-01K-111SBL137005R11013/90AF09-30-01K-121SBL137005R12013/90AF09-30-01K-131SBL137005R13013/90AF09-30-01K-141SBL137005R14013/90AF09-30-10-111SBL137001R11103/14AF09-30-10-121SBL137001R12103/14AF09-30-10-131SBL137001R13103/14AF09-30-10-141SBL137001R14103/14AF09-30-10K-111SBL137005R11103/90AF09-30-10K-121SBL137005R12103/90AF09-30-10K-131SBL137005R13103/90AF09-30-10K-141SBL137005R14103/90AF09-30-22-111SBL137001R11223/38AF09-30-22-121SBL137001R12223/38AF09-30-22-131SBL137001R13223/38AF09-30-22-141SBL137001R14223/38AF09-40-00-111SBL137201R1100 3/134AF09-40-00-121SBL137201R1200 3/134AF09-40-00-131SBL137201R1300 3/134AF09-40-00-141SBL137201R1400 3/134AF09Z-22-00-201SBL136501R2000 3/136AF09Z-22-00-211SBL136501R2100 3/136AF09Z-22-00-221SBL136501R2200 3/136AF09Z-22-00-231SBL136501R2300 3/136AF09Z-22-00-301SBL136501R3000 3/135AF09Z-30-01-201SBL136001R20013/16AF09Z-30-01-211SBL136001R21013/16AF09Z-30-01-221SBL136001R22013/16AF09Z-30-01-231SBL136001R23013/16AF09Z-30-01-301SBL136001R30013/15AF09Z-30-01K-201SBL136005R20013/92AF09Z-30-01K-211SBL136005R21013/92AF09Z-30-01K-221SBL136005R22013/92AF09Z-30-01K-231SBL136005R23013/92AF09Z-30-01K-301SBL136005R30013/91AF09Z-30-10-111SBL136001R111012/6AF09Z-30-10-201SBL136001R20103/16AF09Z-30-10-211SBL136001R21103/16AF09Z-30-10-221SBL136001R22103/16AF09Z-30-10-231SBL136001R23103/16AF09Z-30-10-301SBL136001R30103/15AF09Z-30-10K-201SBL136005R20103/92AF09Z-30-10K-211SBL136005R21103/92AF09Z-30-10K-221SBL136005R22103/92AF09Z-30-10K-231SBL136005R23103/92AF09Z-30-10K-301SBL136005R30103/91AF09Z-30-22-201SBL136001R20223/39AF09Z-30-22-211SBL136001R21223/39AF09Z-30-22-221SBL136001R22223/39AF09Z-30-22-231SBL136001R23223/39AF09Z-40-00-201SBL136201R2000 3/136AF09Z-40-00-211SBL136201R2100 3/136AF09Z-40-00-221SBL136201R2200 3/136AF09Z-40-00-231SBL136201R2300 3/136AF09Z-40-00-301SBL136201R3000 3/135AF116-30-00-111SFL427001R11003/19AF116-30-00-121SFL427001R12003/19AF116-30-00-131SFL427001R13003/19AF116-30-00-141SFL427001R14003/19AF116-30-00-331SFL427001R33003/20AF116-30-00-341SFL427001R34003/20AF116-30-00B-111SFL427002R11003/19AF116-30-00B-121SFL427002R12003/19AF116-30-00B-131SFL427002R13003/19AF116-30-00B-141SFL427002R14003/19AF116-30-00B-331SFL427002R33003/20AF116-30-00B-341SFL427002R34003/20AF116-30-11-111SFL427001R11113/29AF116-30-11-11 1SFL427001R1111 12/85AF116-30-11-121SFL427001R12113/29AF116-30-11-131SFL427001R13113/29AF116-30-11-141SFL427001R14113/29AF116-30-11-331SFL427001R33113/30AF116-30-11-341SFL427001R34113/30AF116-30-11B-111SFL427002R11113/29AF116-30-11B-121SFL427002R12113/29AF116-30-11B-131SFL427002R13113/29AF116-30-11B-141SFL427002R14113/29AF116-30-11B-331SFL427002R33113/30AF116-30-11B-341SFL427002R34113/30AF116-30-22-111SFL427001R11223/42AF116-30-22-121SFL427001R12223/42AF116-30-22-131SFL427001R13223/42AF116-30-22-141SFL427001R14223/42AF116-30-22-331SFL427001R33223/43AF116-30-22-341SFL427001R34223/43AF116-30-22B-111SFL427002R11223/42AF116-30-22B-121SFL427002R12223/42AF116-30-22B-131SFL427002R13223/42AF116-30-22B-141SFL427002R14223/42AF116-30-22B-331SFL427002R33223/43AF116-30-22B-341SFL427002R34223/43AF116-40-00-111SFL427101R1100 3/139AF116-40-00-121SFL427101R1200 3/139AF116-40-00-131SFL427101R1300 3/139AF116-40-00-141SFL427101R1400 3/139AF116-40-00B-111SFL427102R11003/139AF116-40-00B-121SFL427102R12003/139AF116-40-00B-131SFL427102R13003/139AF116-40-00B-141SFL427102R14003/139AF116-40-11-111SFL427101R11113/142AF116-40-11-121SFL427101R12113/142AF116-40-11-131SFL427101R13113/142AF116-40-11-141SFL427101R1411 3/142AF116-40-11B-111SFL427102R11113/142AF116-40-11B-121SFL427102R12113/142AF116-40-11B-131SFL427102R13113/142AF116-40-11B-141SFL427102R14113/142AF116-40-22-111SFL427101R1122 3/145AF116-40-22-121SFL427101R1222 3/145AF116-40-22-131SFL427101R1322 3/145AF116-40-22-141SFL427101R1422 3/145AF116-40-22B-111SFL427102R11223/145AF116-40-22B-121SFL427102R12223/145AF116-40-22B-131SFL427102R13223/145AF116-40-22B-141SFL427102R14223/145AF12-30-01-111SBL157001R11013/14AF12-30-01-121SBL157001R12013/14AF12-30-01-131SBL157001R13013/14AF12-30-01-141SBL157001R14013/14AF12-30-01K-111SBL157005R11013/90AF12-30-01K-121SBL157005R12013/90AF12-30-01K-131SBL157005R13013/90AF12-30-01K-141SBL157005R14013/90AF12-30-10-111SBL157001R11103/14AF12-30-10-121SBL157001R12103/14AF12-30-10-131SBL157001R13103/14AF12-30-10-141SBL157001R14103/14AF12-30-10K-111SBL157005R11103/90AF12-30-10K-121SBL157005R12103/90AF12-30-10K-131SBL157005R13103/90AF12-30-10K-141SBL157005R14103/90AF12-30-22-111SBL157001R11223/38AF12-30-22-121SBL157001R12223/38AF12-30-22-131SBL157001R13223/38AF12-30-22-141SBL157001R1422 3/38AF1250-30-111SFL647001R6811 3/351SFL647001R6911 3/351SFL647001R7011 3/351SFL647001R7111 3/35AF1250-30-221SFL647001R6822 3/481SFL647001R6922 3/481SFL647001R7022 3/481SFL647001R7122 3/48AF12Z-30-01-201SBL156001R20013/16AF12Z-30-01-211SBL156001R21013/16AF12Z-30-01-221SBL156001R22013/16AF12Z-30-01-231SBL156001R23013/16AF12Z-30-01-301SBL156001R30013/15AF12Z-30-01K-201SBL156005R20013/92AF12Z-30-01K-211SBL156005R21013/92AF12Z-30-01K-221SBL156005R22013/92AF12Z-30-01K-231SBL156005R23013/92AF12Z-30-01K-301SBL156005R30013/91AF12Z-30-10-111SBL156001R111012/6AF12Z-30-10-201SBL156001R20103/16AF12Z-30-10-211SBL156001R21103/16AF12Z-30-10-221SBL156001R22103/16AF12Z-30-10-231SBL156001R23103/16AF12Z-30-10-301SBL156001R30103/15AF12Z-30-10K-201SBL156005R20103/92AF12Z-30-10K-211SBL156005R21103/92AF12Z-30-10K-221SBL156005R22103/92AF12Z-30-10K-231SBL156005R23103/92AF12Z-30-10K-301SBL156005R30103/91AF12Z-30-22-201SBL156001R20223/39AF12Z-30-22-211SBL156001R21223/39AF12Z-30-22-221SBL156001R22223/39AF12Z-30-22-231SBL156001R23223/39AF1350-30-111SFL657001R7011 3/35AF1350-30-221SFL657001R7022 3/48AF1350T-30-11 1SFL657001R9101 3/36AF140-30-00-111SFL447001R11003/19AF140-30-00-121SFL447001R12003/19AF140-30-00-131SFL447001R13003/19AF140-30-00-141SFL447001R14003/19AF140-30-00-331SFL447001R33003/20AF140-30-00-341SFL447001R34003/20AF140-30-00B-111SFL447002R11003/19AF140-30-00B-121SFL447002R12003/19AF140-30-00B-131SFL447002R13003/19AF140-30-00B-141SFL447002R14003/19AF140-30-00B-331SFL447002R33003/20AF140-30-00B-341SFL447002R34003/20AF140-30-11-111SFL447001R11113/29AF140-30-11-121SFL447001R12113/29AF140-30-11-131SFL447001R13113/29AF140-30-11-141SFL447001R14113/29AF140-30-11-331SFL447001R33113/3014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/16AF140-30-11-34 1SFL447001R3411 3/30AF140-30-11B-11 1SFL447002R1111 3/29AF140-30-11B-12 1SFL447002R1211 3/29AF140-30-11B-13 1SFL447002R1311 3/29AF140-30-11B-14 1SFL447002R1411 3/29AF140-30-11B-33 1SFL447002R3311 3/30AF140-30-11B-34 1SFL447002R3411 3/30AF140-30-22-11 1SFL447001R1122 3/42AF140-30-22-12 1SFL447001R1222 3/42AF140-30-22-13 1SFL447001R1322 3/42 1SFL447001R1422 3/42AF140-30-22-33 1SFL447001R3322 3/43AF140-30-22-34 1SFL447001R3422 3/43AF140-30-22B-11 1SFL447002R1122 3/42AF140-30-22B-12 1SFL447002R1222 3/42AF140-30-22B-13 1SFL447002R1322 3/42AF140-30-22B-14 1SFL447002R1422 3/42AF140-30-22B-33 1SFL447002R3322 3/43AF140-30-22B-34 1SFL447002R3422 3/43AF140-40-00-11 1SFL447101R1100 3/139AF140-40-00-12 1SFL447101R1200 3/139AF140-40-00-13 1SFL447101R1300 3/139AF140-40-00-14 1SFL447101R1400 3/139AF140-40-00B-11 1SFL447102R1100 3/139AF140-40-00B-12 1SFL447102R1200 3/139AF140-40-00B-13 1SFL447102R1300 3/139AF140-40-00B-14 1SFL447102R1400 3/139AF140-40-11-11 1SFL447101R1111 3/142AF140-40-11-12 1SFL447101R1211 3/142AF140-40-11-13 1SFL447101R1311 3/142AF140-40-11-14 1SFL447101R1411 3/142AF140-40-11B-11 1SFL447102R1111 3/142AF140-40-11B-12 1SFL447102R1211 3/142AF140-40-11B-13 1SFL447102R1311 3/142AF140-40-11B-14 1SFL447102R1411 3/142AF140-40-22-11 1SFL447101R1122 3/145AF140-40-22-12 1SFL447101R1222 3/145AF140-40-22-13 1SFL447101R1322 3/145AF140-40-22-14 1SFL447101R1422 3/145AF140-40-22B-11 1SFL447102R1122 3/145AF140-40-22B-12 1SFL447102R1222 3/145AF140-40-22B-13 1SFL447102R1322 3/145AF140-40-22B-14 1SFL447102R1422 3/145AF146-30-00-11 1SFL467001R1100 3/19AF146-30-00-12 1SFL467001R1200 3/19AF146-30-00-13 1SFL467001R1300 3/19AF146-30-00-14 1SFL467001R1400 3/19AF146-30-00-33 1SFL467001R3300 3/20AF146-30-00-34 1SFL467001R3400 3/20AF146-30-00B-11 1SFL467002R1100 3/19AF146-30-00B-12 1SFL467002R1200 3/19AF146-30-00B-13 1SFL467002R1300 3/19AF146-30-00B-14 1SFL467002R1400 3/19AF146-30-00B-33 1SFL467002R3300 3/20AF146-30-00B-34 1SFL467002R3400 3/20AF146-30-11-11 1SFL467001R1111 3/29AF146-30-11-12 1SFL467001R1211 3/29AF146-30-11-13 1SFL467001R1311 3/29AF146-30-11-14 1SFL467001R1411 3/29AF146-30-11-33 1SFL467001R3311 3/30AF146-30-11-34 1SFL467001R3411 3/30AF146-30-11B-11 1SFL467002R1111 3/29AF146-30-11B-12 1SFL467002R1211 3/29AF146-30-11B-13 1SFL467002R1311 3/29AF146-30-11B-14 1SFL467002R1411 3/29AF146-30-11B-33 1SFL467002R3311 3/30AF146-30-11B-34 1SFL467002R3411 3/30AF146-30-22-11 1SFL467001R1122 3/42AF146-30-22-12 1SFL467001R1222 3/42AF146-30-22-13 1SFL467001R1322 3/42AF146-30-22-14 1SFL467001R1422 3/42AF146-30-22-33 1SFL467001R3322 3/43AF146-30-22-34 1SFL467001R3422 3/43AF146-30-22B-11 1SFL467002R1122 3/42AF146-30-22B-12 1SFL467002R1222 3/42AF146-30-22B-13 1SFL467002R1322 3/42AF146-30-22B-14 1SFL467002R1422 3/42AF146-30-22B-33 1SFL467002R3322 3/43AF146-30-22B-34 1SFL467002R3422 3/43AF16-22-00-11 1SBL177501R1100 3/134AF16-22-00-12 1SBL177501R1200 3/134AF16-22-00-13 1SBL177501R1300 3/134AF16-22-00-14 1SBL177501R1400 3/134AF16-30-01-11 1SBL177001R1101 3/14AF16-30-01-12 1SBL177001R1201 3/14AF16-30-01-13 1SBL177001R1301 3/14AF16-30-01-14 1SBL177001R1401 3/14AF16-30-01K-11 1SBL177005R1101 3/90AF16-30-01K-12 1SBL177005R1201 3/90AF16-30-01K-13 1SBL177005R1301 3/90AF16-30-01K-14 1SBL177005R1401 3/90AF16-30-10-11 1SBL177001R1110 3/14AF16-30-10-12 1SBL177001R1210 3/14AF16-30-10-13 1SBL177001R1310 3/14AF16-30-10-14 1SBL177001R1410 3/14AF16-30-10K-11 1SBL177005R1110 3/90AF16-30-10K-12 1SBL177005R1210 3/90AF16-30-10K-13 1SBL177005R1310 3/90AF16-30-10K-14 1SBL177005R1410 3/90AF16-30-22-11 1SBL177001R1122 3/38AF16-30-22-12 1SBL177001R1222 3/38AF16-30-22-13 1SBL177001R1322 3/38AF16-30-22-14 1SBL177001R1422 3/38AF16-40-00-11 1SBL177201R1100 3/134AF16-40-00-12 1SBL177201R1200 3/134AF16-40-00-13 1SBL177201R1300 3/134AF16-40-00-14 1SBL177201R1400 3/134AF1650-30-11 1SFL677001R7011 3/35AF1650-30-22 1SFL677001R7022 3/48AF1650T-30-11 1SFL677001R9101 3/36AF16Z-22-00-20 1SBL176501R2000 3/136AF16Z-22-00-21 1SBL176501R2100 3/136AF16Z-22-00-22 1SBL176501R2200 3/136AF16Z-22-00-23 1SBL176501R2300 3/136AF16Z-22-00-30 1SBL176501R3000 3/135AF16Z-30-01-20 1SBL176001R2001 3/16AF16Z-30-01-21 1SBL176001R2101 3/16AF16Z-30-01-22 1SBL176001R2201 3/16AF16Z-30-01-23 1SBL176001R2301 3/16AF16Z-30-01-30 1SBL176001R3001 3/15AF16Z-30-01K-20 1SBL176005R2001 3/92AF16Z-30-01K-21 1SBL176005R2101 3/92AF16Z-30-01K-22 1SBL176005R2201 3/92AF16Z-30-01K-23 1SBL176005R2301 3/92AF16Z-30-01K-30 1SBL176005R3001 3/91AF16Z-30-10-11 1SBL176001R1110 12/6 AF16Z-30-10-20 1SBL176001R2010 3/16AF16Z-30-10-21 1SBL176001R2110 3/16AF16Z-30-10-22 1SBL176001R2210 3/16AF16Z-30-10-23 1SBL176001R2310 3/16AF16Z-30-10-30 1SBL176001R3010 3/15AF16Z-30-10K-20 1SBL176005R2010 3/92AF16Z-30-10K-21 1SBL176005R2110 3/92AF16Z-30-10K-22 1SBL176005R2210 3/92AF16Z-30-10K-23 1SBL176005R2310 3/92AF16Z-30-10K-30 1SBL176005R3010 3/91AF16Z-30-22-20 1SBL176001R2022 3/39AF16Z-30-22-21 1SBL176001R2122 3/39AF16Z-30-22-22 1SBL176001R2222 3/39AF16Z-30-22-23 1SBL176001R2322 3/39AF16Z-40-00-20 1SBL176201R2000 3/136AF16Z-40-00-21 1SBL176201R2100 3/136AF16Z-40-00-22 1SBL176201R2200 3/136AF16Z-40-00-23 1SBL176201R2300 3/136AF16Z-40-00-30 1SBL176201R3000 3/135AF190-30-00-11 1SFL487002R1100 3/21AF190-30-00-12 1SFL487002R1200 3/21AF190-30-00-13 1SFL487002R1300 3/21AF190-30-00-14 1SFL487002R1400 3/21AF190-30-00-33 1SFL487002R3300 3/22AF190-30-00-34 1SFL487002R3400 3/22AF190-30-11-11 1SFL487002R1111 3/31AF190-30-11-12 1SFL487002R1211 3/31AF190-30-11-13 1SFL487002R1311 3/31AF190-30-11-14 1SFL487002R1411 3/31AF190-30-11-33 1SFL487002R3311 3/32AF190-30-11-34 1SFL487002R3411 3/32AF190-30-22-11 1SFL487002R1122 3/44AF190-30-22-12 1SFL487002R1222 3/44AF190-30-22-13 1SFL487002R1322 3/44AF190-30-22-14 1SFL487002R1422 3/44AF190-30-22-33 1SFL487002R3322 3/45AF190-30-22-34 1SFL487002R3422 3/45AF190-40-00-11 1SFL487102R1100 3/140AF190-40-00-12 1SFL487102R1200 3/140AF190-40-00-13 1SFL487102R1300 3/140AF190-40-00-14 1SFL487102R1400 3/140AF190-40-11-11 1SFL487102R1111 3/143AF190-40-11-12 1SFL487102R1211 3/143AF190-40-11-13 1SFL487102R1311 3/143AF190-40-11-14 1SFL487102R1411 3/143AF190-40-22-11 1SFL487102R1122 3/146AF190-40-22-12 1SFL487102R1222 3/146AF190-40-22-13 1SFL487102R1322 3/146AF190-40-22-14 1SFL487102R1422 3/146AF2050-30-11 1SFL707001R7011 3/35AF2050-30-22 1SFL707001R7022 3/48AF2050T-30-11 1SFL707001R9101 3/36AF205-30-00-11 1SFL527002R1100 3/21AF205-30-00-12 1SFL527002R1200 3/21AF205-30-00-13 1SFL527002R1300 3/21AF205-30-00-14 1SFL527002R1400 3/21AF205-30-00-33 1SFL527002R3300 3/22AF205-30-00-34 1SFL527002R3400 3/22AF205-30-11-11 1SFL527002R1111 3/31AF205-30-11-12 1SFL527002R1211 3/31AF205-30-11-13 1SFL527002R1311 3/31AF205-30-11-14 1SFL527002R1411 3/31AF205-30-11-33 1SFL527002R3311 3/32AF205-30-11-34 1SFL527002R3411 3/32AF205-30-22-11 1SFL527002R1122 3/44AF205-30-22-12 1SFL527002R1222 3/44AF205-30-22-13 1SFL527002R1322 3/44AF205-30-22-14 1SFL527002R1422 3/44AF205-30-22-33 1SFL527002R3322 3/45AF205-30-22-34 1SFL527002R3422 3/45AF205-40-00-11 1SFL527102R1100 3/140AF205-40-00-12 1SFL527102R1200 3/140AF205-40-00-13 1SFL527102R1300 3/140AF205-40-00-14 1SFL527102R1400 3/14014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/17ABB MOTOR PROTECTION AND CONTROLAF205-40-11-111SFL527102R11113/143AF205-40-11-121SFL527102R12113/143AF205-40-11-131SFL527102R13113/143AF205-40-11-141SFL527102R14113/143AF205-40-22-111SFL527102R11223/146AF205-40-22-121SFL527102R1222 3/146AF205-40-22-131SFL527102R1322 3/146AF205-40-22-141SFL527102R1422 3/146AF26-22-00-111SBL237501R1100 3/134AF26-22-00-121SBL237501R1200 3/134AF26-22-00-131SBL237501R1300 3/134AF26-22-00-141SBL237501R1400 3/134AF26-30-00-111SBL237001R11003/14AF26-30-00-121SBL237001R12003/14AF26-30-00-131SBL237001R13003/14AF26-30-00-141SBL237001R1400 3/14AF26-30-00K-111SBL237005R11003/90AF26-30-00K-121SBL237005R12003/90AF26-30-00K-131SBL237005R13003/90AF26-30-00K-141SBL237005R14003/90AF26-30-11-111SBL237001R11113/24AF26-30-11-121SBL237001R12113/24AF26-30-11-131SBL237001R13113/24AF26-30-11-141SBL237001R14113/24AF26-30-22-111SBL237001R11223/38AF26-30-22-121SBL237001R12223/38AF26-30-22-131SBL237001R13223/38AF26-30-22-141SBL237001R1422 3/38AF26-40-00-111SBL237201R1100 3/134AF26-40-00-121SBL237201R1200 3/134AF26-40-00-131SBL237201R1300 3/134AF26-40-00-141SBL237201R1400 3/134AF2650-30-111SFL667001R7011 3/35AF2650-30-221SFL667001R7022 3/48AF2650T-30-11 1SFL667001R9101 3/36AF265-30-00-111SFL547002R11003/21AF265-30-00-121SFL547002R12003/21AF265-30-00-131SFL547002R13003/21AF265-30-00-141SFL547002R14003/21AF265-30-00-331SFL547002R33003/22AF265-30-00-341SFL547002R34003/22AF265-30-11-111SFL547002R11113/31AF265-30-11-121SFL547002R12113/31AF265-30-11-131SFL547002R13113/31AF265-30-11-141SFL547002R14113/31AF265-30-11-331SFL547002R33113/32AF265-30-11-341SFL547002R34113/32AF265-30-22-111SFL547002R11223/44AF265-30-22-121SFL547002R12223/44AF265-30-22-131SFL547002R13223/44AF265-30-22-141SFL547002R14223/44AF265-30-22-331SFL547002R33223/45AF265-30-22-341SFL547002R34223/45AF265-40-00-111SFL547102R1100 3/140AF265-40-00-121SFL547102R1200 3/140AF265-40-00-131SFL547102R1300 3/140AF265-40-00-141SFL547102R1400 3/140AF265-40-11-111SFL547102R11113/143AF265-40-11-121SFL547102R12113/143AF265-40-11-131SFL547102R13113/143AF265-40-11-141SFL547102R14113/143AF265-40-22-111SFL547102R1122 3/146AF265-40-22-121SFL547102R1222 3/146AF265-40-22-131SFL547102R1322 3/146AF265-40-22-141SFL547102R1422 3/146AF26Z-22-00-201SBL236501R2000 3/136AF26Z-22-00-211SBL236501R2100 3/136AF26Z-22-00-221SBL236501R2200 3/136AF26Z-22-00-231SBL236501R2300 3/136AF26Z-30-00-111SBL236001R110012/6AF26Z-30-00-201SBL236001R20003/16AF26Z-30-00-211SBL236001R21003/16AF26Z-30-00-221SBL236001R22003/16AF26Z-30-00-231SBL236001R23003/16AF26Z-30-00-301SBL236001R30003/15AF26Z-30-00K-201SBL236005R20003/92AF26Z-30-00K-211SBL236005R21003/92AF26Z-30-00K-221SBL236005R22003/92AF26Z-30-00K-231SBL236005R23003/92AF26Z-30-00K-301SBL236005R30003/91AF26Z-30-11-201SBL236001R20113/25AF26Z-30-11-211SBL236001R21113/25AF26Z-30-11-221SBL236001R22113/25AF26Z-30-11-231SBL236001R23113/25AF26Z-30-22-201SBL236001R20223/39AF26Z-30-22-211SBL236001R21223/39AF26Z-30-22-221SBL236001R22223/39AF26Z-30-22-231SBL236001R23223/39AF26Z-40-00-201SBL236201R2000 3/136AF26Z-40-00-211SBL236201R2100 3/136AF26Z-40-00-221SBL236201R2200 3/136AF26Z-40-00-231SBL236201R2300 3/136AF2850-30-111SFL687001R7011 3/35AF2850-30-221SFL687001R7022 3/48AF2850T-30-11 1SFL687001R9101 3/36AF30-30-00-111SBL277001R11003/14AF30-30-00-121SBL277001R12003/14AF30-30-00-131SBL277001R13003/14AF30-30-00-141SBL277001R14003/14AF30-30-00K-111SBL277005R11003/90AF30-30-00K-121SBL277005R12003/90AF30-30-00K-131SBL277005R13003/90AF30-30-00K-141SBL277005R14003/90AF30-30-11-111SBL277001R11113/24AF30-30-11-121SBL277001R12113/24AF30-30-11-131SBL277001R13113/24AF30-30-11-141SBL277001R14113/24AF30-30-22-111SBL277001R11223/38AF30-30-22-121SBL277001R12223/38AF30-30-22-131SBL277001R13223/38AF30-30-22-141SBL277001R14223/38AF305-30-00-111SFL587002R11003/21AF305-30-00-121SFL587002R12003/21AF305-30-00-131SFL587002R13003/21AF305-30-00-141SFL587002R14003/21AF305-30-00-331SFL587002R33003/22AF305-30-00-341SFL587002R34003/22AF305-30-11-111SFL587002R11113/31AF305-30-11-121SFL587002R12113/31AF305-30-11-131SFL587002R13113/31AF305-30-11-141SFL587002R14113/31AF305-30-11-331SFL587002R33113/32AF305-30-11-341SFL587002R34113/32AF305-30-22-111SFL587002R11223/44AF305-30-22-121SFL587002R12223/44AF305-30-22-131SFL587002R13223/44AF305-30-22-141SFL587002R14223/44AF305-30-22-331SFL587002R33223/45AF305-30-22-341SFL587002R34223/45AF305-40-00-111SFL587102R1100 3/140AF305-40-00-121SFL587102R1200 3/140AF305-40-00-131SFL587102R1300 3/140AF305-40-00-141SFL587102R1400 3/140AF305-40-11-111SFL587102R11113/143AF305-40-11-121SFL587102R12113/143AF305-40-11-131SFL587102R13113/143AF305-40-11-141SFL587102R14113/143AF305-40-22-111SFL587102R1122 3/146AF305-40-22-121SFL587102R1222 3/146AF305-40-22-131SFL587102R1322 3/146AF305-40-22-141SFL587102R1422 3/146AF30Z-30-00-111SBL276001R110012/6AF30Z-30-00-201SBL276001R20003/16AF30Z-30-00-211SBL276001R21003/16AF30Z-30-00-221SBL276001R22003/16AF30Z-30-00-231SBL276001R23003/16AF30Z-30-00-301SBL276001R30003/15AF30Z-30-00K-201SBL276005R20003/92AF30Z-30-00K-211SBL276005R21003/92AF30Z-30-00K-221SBL276005R22003/92AF30Z-30-00K-231SBL276005R23003/92AF30Z-30-00K-301SBL276005R30003/91AF30Z-30-11-201SBL276001R20113/25AF30Z-30-11-211SBL276001R21113/25AF30Z-30-11-221SBL276001R22113/25AF30Z-30-11-231SBL276001R23113/25AF30Z-30-22-201SBL276001R20223/39AF30Z-30-22-211SBL276001R21223/39AF30Z-30-22-221SBL276001R22223/39AF30Z-30-22-231SBL276001R23223/39AF370-30-00-111SFL607002R11003/21AF370-30-00-121SFL607002R12003/21AF370-30-00-131SFL607002R13003/21AF370-30-00-141SFL607002R14003/21AF370-30-00-331SFL607002R33003/22AF370-30-00-341SFL607002R34003/22AF370-30-11-111SFL607002R11113/31AF370-30-11-121SFL607002R12113/31AF370-30-11-131SFL607002R13113/31AF370-30-11-141SFL607002R14113/31AF370-30-11-331SFL607002R33113/32AF370-30-11-341SFL607002R34113/32AF370-30-22-111SFL607002R11223/44AF370-30-22-121SFL607002R12223/44AF370-30-22-131SFL607002R13223/44AF370-30-22-141SFL607002R14223/44AF370-30-22-331SFL607002R33223/45AF370-30-22-341SFL607002R34223/45AF370-40-00-111SFL607102R1100 3/140AF370-40-00-121SFL607102R1200 3/140AF370-40-00-131SFL607102R1300 3/140AF370-40-00-141SFL607102R1400 3/140AF370-40-11-111SFL607102R11113/143AF370-40-11-121SFL607102R12113/143AF370-40-11-131SFL607102R13113/143AF370-40-11-141SFL607102R1411 3/143AF370-40-22-111SFL607102R1122 3/146AF370-40-22-121SFL607102R1222 3/146AF370-40-22-131SFL607102R1322 3/146AF370-40-22-141SFL607102R1422 3/146AF38-22-00-111SBL297501R1100 3/134AF38-22-00-121SBL297501R1200 3/134AF38-22-00-131SBL297501R1300 3/134AF38-22-00-141SBL297501R1400 3/134AF38-30-00-111SBL297001R11003/14AF38-30-00-121SBL297001R1200 3/14AF38-30-00-131SBL297001R1300 3/14AF38-30-00-141SBL297001R1400 3/14AF38-30-00K-111SBL297005R11003/90AF38-30-00K-121SBL297005R12003/90AF38-30-00K-131SBL297005R13003/9014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/18AF38-30-00K-14 1SBL297005R1400 3/90AF38-30-11-11 1SBL297001R1111 3/24AF38-30-11-12 1SBL297001R1211 3/24AF38-30-11-13 1SBL297001R1311 3/24AF38-30-11-14 1SBL297001R1411 3/24AF38-30-22-11 1SBL297001R1122 3/38AF38-30-22-12 1SBL297001R1222 3/38AF38-30-22-13 1SBL297001R1322 3/38AF38-30-22-14 1SBL297001R1422 3/38AF38-40-00-11 1SBL297201R1100 3/134AF38-40-00-12 1SBL297201R1200 3/134AF38-40-00-13 1SBL297201R1300 3/134AF38-40-00-14 1SBL297201R1400 3/134AF38Z-22-00-20 1SBL296501R2000 3/136AF38Z-22-00-21 1SBL296501R2100 3/136AF38Z-22-00-22 1SBL296501R2200 3/136AF38Z-22-00-23 1SBL296501R2300 3/136AF38Z-30-00-11 1SBL296001R1100 12/36AF38Z-30-00-20 1SBL296001R2000 3/16AF38Z-30-00-21 1SBL296001R2100 3/16AF38Z-30-00-22 1SBL296001R2200 3/16AF38Z-30-00-23 1SBL296001R2300 3/16AF38Z-30-00-30 1SBL296001R3000 3/15AF38Z-30-00K-20 1SBL296005R2000 3/92AF38Z-30-00K-21 1SBL296005R2100 3/92AF38Z-30-00K-22 1SBL296005R2200 3/92AF38Z-30-00K-23 1SBL296005R2300 3/92AF38Z-30-00K-30 1SBL296005R3000 3/91AF38Z-30-11-20 1SBL296001R2011 3/25AF38Z-30-11-21 1SBL296001R2111 3/25AF38Z-30-11-22 1SBL296001R2211 3/25AF38Z-30-11-23 1SBL296001R2311 3/25AF38Z-30-22-20 1SBL296001R2022 3/39AF38Z-30-22-21 1SBL296001R2122 3/39AF38Z-30-22-22 1SBL296001R2222 3/39AF38Z-30-22-23 1SBL296001R2322 3/39AF38Z-40-00-20 1SBL296201R2000 3/136AF38Z-40-00-21 1SBL296201R2100 3/136AF38Z-40-00-22 1SBL296201R2200 3/136AF38Z-40-00-23 1SBL296201R2300 3/136AF400-30-11 1SFL577001R6811 3/34 1SFL577001R6911 3/34 1SFL577001R7011 3/34 1SFL577001R7111 3/34AF400-30-22 1SFL577001R6822 3/47 1SFL577001R6922 3/47 1SFL577001R7022 3/47 1SFL577001R7122 3/47AF40-22-00-11 1SBL347501R1100 3/137AF40-22-00-12 1SBL347501R1200 3/137AF40-22-00-13 1SBL347501R1300 3/137AF40-22-00-14 1SBL347501R1400 3/137AF40-30-00-11 1SBL347001R1100 3/17AF40-30-00-12 1SBL347001R1200 3/17AF40-30-00-13 1SBL347001R1300 3/17AF40-30-00-14 1SBL347001R1400 3/17AF40-30-11-11 1SBL347001R1111 3/27AF40-30-11-12 1SBL347001R1211 3/27AF40-30-11-13 1SBL347001R1311 3/27AF40-30-11-14 1SBL347001R1411 3/27AF40-30-22-11 1SBL347001R1122 3/40AF40-30-22-12 1SBL347001R1222 3/40AF40-30-22-13 1SBL347001R1322 3/40AF40-30-22-14 1SBL347001R1422 3/40AF40-40-00-11 1SBL347201R1100 3/137AF40-40-00-12 1SBL347201R1200 3/137AF40-40-00-13 1SBL347201R1300 3/137AF40-40-00-14 1SBL347201R1400 3/137AF460-30-11 1SFL597001R6811 3/34 1SFL597001R6911 3/34 1SFL597001R7011 3/34 1SFL597001R7111 3/34AF460-30-22 1SFL597001R6822 3/47 1SFL597001R6922 3/47 1SFL597001R7022 3/47 1SFL597001R7122 3/47AF52-30-00-11 1SBL367001R1100 3/17AF52-30-00-12 1SBL367001R1200 3/17AF52-30-00-13 1SBL367001R1300 3/17AF52-30-00-14 1SBL367001R1400 3/17AF52-30-11-11 1SBL367001R1111 3/27AF52-30-11-12 1SBL367001R1211 3/27AF52-30-11-13 1SBL367001R1311 3/27AF52-30-11-14 1SBL367001R1411 3/27AF52-30-22-11 1SBL367001R1122 3/40AF52-30-22-12 1SBL367001R1222 3/40AF52-30-22-13 1SBL367001R1322 3/40AF52-30-22-14 1SBL367001R1422 3/40AF52-40-00-11 1SBL367201R1100 3/137AF52-40-00-12 1SBL367201R1200 3/137AF52-40-00-13 1SBL367201R1300 3/137AF52-40-00-14 1SBL367201R1400 3/137AF580-30-11 1SFL617001R6811 3/34 1SFL617001R6911 3/34 1SFL617001R7011 3/34 1SFL617001R7111 3/34AF580-30-22 1SFL617001R6822 3/47 1SFL617001R6922 3/47 1SFL617001R7022 3/47 1SFL617001R7122 3/47AF65-30-00-11 1SBL387001R1100 3/17AF65-30-00-12 1SBL387001R1200 3/17AF65-30-00-13 1SBL387001R1300 3/17AF65-30-00-14 1SBL387001R1400 3/17AF65-30-11-11 1SBL387001R1111 3/27AF65-30-11-12 1SBL387001R1211 3/27AF65-30-11-13 1SBL387001R1311 3/27AF65-30-11-14 1SBL387001R1411 3/27AF65-30-22-11 1SBL387001R1122 3/40AF65-30-22-12 1SBL387001R1222 3/40AF65-30-22-13 1SBL387001R1322 3/40AF65-30-22-14 1SBL387001R1422 3/40AF750-30-11 1SFL637001R6811 3/34 1SFL637001R6911 3/34 1SFL637001R7011 3/34 1SFL637001R7111 3/34AF750-30-22 1SFL637001R6822 3/47 1SFL637001R6922 3/47 1SFL637001R7022 3/47 1SFL637001R7122 3/47AF80-22-00-11 1SBL397501R1100 3/137AF80-22-00-12 1SBL397501R1200 3/137AF80-22-00-13 1SBL397501R1300 3/137AF80-22-00-14 1SBL397501R1400 3/137AF80-30-00-11 1SBL397001R1100 3/17AF80-30-00-12 1SBL397001R1200 3/17AF80-30-00-13 1SBL397001R1300 3/17AF80-30-00-14 1SBL397001R1400 3/17AF80-30-11-11 1SBL397001R1111 3/27AF80-30-11-12 1SBL397001R1211 3/27AF80-30-11-13 1SBL397001R1311 3/27AF80-30-11-14 1SBL397001R1411 3/27AF80-30-22-11 1SBL397001R1122 3/40AF80-30-22-12 1SBL397001R1222 3/40AF80-30-22-13 1SBL397001R1322 3/40AF80-30-22-14 1SBL397001R1422 3/40AF80-40-00-11 1SBL397201R1100 3/137AF80-40-00-12 1SBL397201R1200 3/137AF80-40-00-13 1SBL397201R1300 3/137AF80-40-00-14 1SBL397201R1400 3/137AF96-30-00-11 1SBL407001R1100 3/17AF96-30-00-12 1SBL407001R1200 3/17AF96-30-00-13 1SBL407001R1300 3/17AF96-30-00-14 1SBL407001R1400 3/17AF96-30-11-11 1SBL407001R1111 3/27AF96-30-11-12 1SBL407001R1211 3/27AF96-30-11-13 1SBL407001R1311 3/27AF96-30-11-14 1SBL407001R1411 3/27AF96-30-22-11 1SBL407001R1122 3/40AF96-30-22-12 1SBL407001R1222 3/40AF96-30-22-13 1SBL407001R1322 3/40AF96-30-22-14 1SBL407001R1422 3/40AFS09-30-22-11 1SBL137082R1122 3/114AFS09-30-22-13 1SBL137082R1322 3/114AFS09Z-30-22-30 1SBL136082R3022 3/114AFS12-30-22-11 1SBL157082R1122 3/114AFS12-30-22-13 1SBL157082R1322 3/114AFS12Z-30-22-30 1SBL156082R3022 3/114AFS16-30-22-11 1SBL177082R1122 3/114AFS16-30-22-13 1SBL177082R1322 3/114AFS16Z-30-22-30 1SBL176082R3022 3/114AFS26-30-22-11 1SBL237082R1122 3/114AFS26-30-22-13 1SBL237082R1322 3/114AFS26Z-30-22-30 1SBL236082R3022 3/114AFS30-30-22-11 1SBL277082R1122 3/114AFS30-30-22-13 1SBL277082R1322 3/114AFS30Z-30-22-30 1SBL276082R3022 3/114AFS38-30-22-11 1SBL297082R1122 3/114AFS38-30-22-13 1SBL297082R1322 3/114AFS38Z-30-22-30 1SBL296082R3022 3/114AFS40-30-22-11 1SBL347082R1122 3/115AFS40-30-22-13 1SBL347082R1322 3/115AFS52-30-22-11 1SBL367082R1122 3/115AFS52-30-22-13 1SBL367082R1322 3/115AFS65-30-22-11 1SBL387082R1122 3/115AFS65-30-22-13 1SBL387082R1322 3/115AFS80-30-22-11 1SBL397082R1122 3/115AFS80-30-22-13 1SBL397082R1322 3/115AFS96-30-22-11 1SBL407082R1122 3/115AFS96-30-22-13 1SBL407082R1322 3/115AI111.0 1SAJ613000R0101 11/10AS09-30-01-20 1SBL101001R2001 5/8AS09-30-01-26 1SBL101001R2601 5/8AS09-30-01S-20 1SBL101004R2001 5/56AS09-30-01S-26 1SBL101004R2601 5/56AS09-30-10-20 1SBL101001R2010 5/8AS09-30-10-26 1SBL101001R2610 5/8AS09-30-10S-20 1SBL101004R2010 5/56AS09-30-10S-26 1SBL101004R2610 5/56AS09-30-32-20 1SBL101001R2032 5/10AS09-30-32-26 1SBL101001R2632 5/10AS09-30-32S-20 1SBL101004R2032 5/58AS09-30-32S-26 1SBL101004R2632 5/58AS12-30-01-20 1SBL111001R2001 5/8AS12-30-01-26 1SBL111001R2601 5/8AS12-30-01S-20 1SBL111004R2001 5/56AS12-30-01S-26 1SBL111004R2601 5/56AS12-30-10-20 1SBL111001R2010 5/8AS12-30-10-26 1SBL111001R2610 5/8AS12-30-10S-20 1SBL111004R2010 5/56AS12-30-10S-26 1SBL111004R2610 5/5614
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/19ABB MOTOR PROTECTION AND CONTROLAS12-30-32-201SBL111001R20325/10AS12-30-32-261SBL111001R26325/10AS12-30-32S-201SBL111004R20325/58AS12-30-32S-261SBL111004R26325/58AS16-30-01-201SBL121001R20015/8AS16-30-01-261SBL121001R26015/8AS16-30-01S-201SBL121004R20015/56AS16-30-01S-261SBL121004R26015/56AS16-30-10-201SBL121001R20105/8AS16-30-10-261SBL121001R26105/8AS16-30-10S-201SBL121004R20105/56AS16-30-10S-261SBL121004R26105/56AS16-30-32-201SBL121001R20325/10AS16-30-32-261SBL121001R26325/10AS16-30-32S-201SBL121004R20325/58AS16-30-32S-261SBL121004R26325/58ASL09-30-01-811SBL103001R81015/9ASL09-30-01S-811SBL103004R81015/57ASL09-30-10-811SBL103001R81105/9ASL09-30-10S-811SBL103004R81105/57ASL09-30-32-811SBL103001R81325/11ASL09-30-32S-811SBL103004R81325/59ASL12-30-01-811SBL113001R81015/9ASL12-30-01S-811SBL113004R81015/57ASL12-30-10-811SBL113001R81105/9ASL12-30-10S-811SBL113004R81105/57ASL12-30-32-811SBL113001R81325/11ASL12-30-32S-811SBL113004R81325/59ASL16-30-01-811SBL123001R81015/9ASL16-30-01S-811SBL123004R81015/57ASL16-30-10-811SBL123001R81105/9ASL16-30-10S-811SBL123004R81105/57ASL16-30-32-811SBL123001R81325/11ASL16-30-32S-811SBL123004R81325/59B6-22-00-01GJL1211501R0001 4/15B6-22-00-02GJL1211501R0002 4/15B6-22-00-03GJL1211501R0003 4/15B6-22-00-80GJL1211501R8000 4/15B6-22-00-84GJL1211501R8004 4/15B6-30-01-01GJL1211001R00114/8B6-30-01-02GJL1211001R00124/8B6-30-01-03GJL1211001R00134/8B6-30-01-80GJL1211001R80104/8B6-30-01-84GJL1211001R80144/8B6-30-01-85GJL1211001R80154/8B6-30-01-F-01GJL1211003R0011 4/30B6-30-01-F-02GJL1211003R0012 4/30B6-30-01-F-03GJL1211003R0013 4/30B6-30-01-F-80GJL1211003R8010 4/30B6-30-01-F-84GJL1211003R8014 4/30B6-30-01-F-85GJL1211003R8015 4/30B6-30-01-P-01GJL1211009R0011 4/20B6-30-01-P-02GJL1211009R0012 4/20B6-30-01-P-03GJL1211009R0013 4/20B6-30-01-P-80GJL1211009R8010 4/20B6-30-01-P-84GJL1211009R8014 4/20B6-30-01-P-85GJL1211009R8015 4/20B6-30-10-01GJL1211001R01014/8B6-30-10-02GJL1211001R01024/8B6-30-10-03GJL1211001R01034/8B6-30-10-80GJL1211001R81004/8B6-30-10-84GJL1211001R81044/8B6-30-10-85GJL1211001R81054/8B6-30-10-F-01GJL1211003R0101 4/30B6-30-10-F-02GJL1211003R0102 4/30B6-30-10-F-03GJL1211003R0103 4/30B6-30-10-F-80GJL1211003R8100 4/30B6-30-10-F-84GJL1211003R8104 4/30B6-30-10-F-85GJL1211003R8105 4/30B6-30-10-P-01GJL1211009R0101 4/20B6-30-10-P-02GJL1211009R0102 4/20B6-30-10-P-03GJL1211009R0103 4/20B6-30-10-P-80GJL1211009R8100 4/20B6-30-10-P-84GJL1211009R8104 4/20B6-30-10-P-85GJL1211009R8105 4/20B6-40-00-01GJL1211201R0001 4/15B6-40-00-02GJL1211201R0002 4/15B6-40-00-03GJL1211201R0003 4/15B6-40-00-80GJL1211201R8000 4/15B6-40-00-84GJL1211201R8004 4/15B6S-30-01-1.7-71GJL1213001R70114/14B6S-30-01-2.8-72GJL1213001R70124/14B6S-30-10-1.7-71GJL1213001R71014/14B6S-30-10-2.8-72GJL1213001R71024/14B7-22-00-01GJL1311501R0001 4/15B7-22-00-02GJL1311501R0002 4/15B7-22-00-03GJL1311501R0003 4/15B7-22-00-80GJL1311501R8000 4/15B7-22-00-84GJL1311501R8004 4/15B7-30-01-01GJL1311001R00114/8B7-30-01-02GJL1311001R00124/8B7-30-01-03GJL1311001R00134/8B7-30-01-80GJL1311001R80104/8B7-30-01-84GJL1311001R80144/8B7-30-01-85GJL1311001R80154/8B7-30-01-F-01GJL1311003R0011 4/30B7-30-01-F-02GJL1311003R0012 4/30B7-30-01-F-03GJL1311003R0013 4/30B7-30-01-F-80GJL1311003R8010 4/30B7-30-01-F-84GJL1311003R8014 4/30B7-30-01-F-85GJL1311003R8015 4/30B7-30-01-P-01GJL1311009R0011 4/20B7-30-01-P-02GJL1311009R0012 4/20B7-30-01-P-03GJL1311009R0013 4/20B7-30-01-P-80GJL1311009R8010 4/20B7-30-01-P-84GJL1311009R8014 4/20B7-30-01-P-85GJL1311009R8015 4/20B7-30-10-01GJL1311001R01014/8B7-30-10-02GJL1311001R01024/8B7-30-10-03GJL1311001R01034/8B7-30-10-80GJL1311001R81004/8B7-30-10-84GJL1311001R81044/8B7-30-10-85GJL1311001R81054/8B7-30-10-F-01GJL1311003R0101 4/30B7-30-10-F-02GJL1311003R0102 4/30B7-30-10-F-03GJL1311003R0103 4/30B7-30-10-F-80GJL1311003R8100 4/30B7-30-10-F-84GJL1311003R8104 4/30B7-30-10-F-85GJL1311003R8105 4/30B7-30-10-P-01GJL1311009R0101 4/20B7-30-10-P-02GJL1311009R0102 4/20B7-30-10-P-03GJL1311009R0103 4/20B7-30-10-P-80GJL1311009R8100 4/20B7-30-10-P-84GJL1311009R8104 4/20B7-30-10-P-85GJL1311009R8105 4/20B7-40-00-01GJL1311201R0001 4/15B7-40-00-02GJL1311201R0002 4/15B7-40-00-03GJL1311201R0003 4/15B7-40-00-80GJL1311201R8000 4/15B7-40-00-84GJL1311201R8004 4/15B7D-30-01-01GJL1317001R00114/9B7D-30-01-05GJL1317001R00154/9B7D-30-10-01GJL1317001R01014/9B7D-30-10-05GJL1317001R01054/9B7D-40-00-01GJL1317201R00014/16B7D-40-00-05GJL1317201R0005 4/16B7S-30-01-1.7-71GJL1313001R70114/14B7S-30-01-2.8-72GJL1313001R70124/14B7S-30-10-1.7-71GJL1313001R71014/14B7S-30-10-2.8-72GJL1313001R71024/14BA41SNA235156R2700 3/256BA5-501SBN110000R1000 3/256BB31SBN111020R1000 5/50BB41SBN110120W1000 3/248BC6-21-10-P-01GJL1213109R01014/21BC6-21-10-P-03GJL1213109R01034/21BC6-21-10-P-04GJL1213109R01044/21BC6-21-10-P-05GJL1213109R01054/21BC6-21-10-P-16GJL1213109R11064/21BC6-22-00-01GJL1213501R0001 4/16BC6-22-00-02GJL1213501R0002 4/16BC6-22-00-03GJL1213501R0003 4/16BC6-22-00-04GJL1213501R0004 4/16BC6-22-00-05GJL1213501R0005 4/16BC6-22-00-07GJL1213501R0007 4/16BC6-22-00-16GJL1213501R1006 4/16BC6-30-01-01GJL1213001R00114/9BC6-30-01-03GJL1213001R00134/9BC6-30-01-04GJL1213001R00144/9BC6-30-01-05GJL1213001R00154/9BC6-30-01-07GJL1213001R00174/9BC6-30-01-1.4-81GJL1213001R80114/14BC6-30-01-16GJL1213001R10164/9BC6-30-01-2.4-51GJL1213001R50114/14BC6-30-01-F-01GJL1213003R00114/31BC6-30-01-F-03GJL1213003R00134/31BC6-30-01-F-04GJL1213003R00144/31BC6-30-01-F-05GJL1213003R00154/31BC6-30-01-F-07GJL1213003R00174/31BC6-30-01-F-1.4-81 GJL1213003R8011 4/36BC6-30-01-F-16GJL1213003R10164/31BC6-30-01-F-2.4-51 GJL1213003R5011 4/36BC6-30-01-P-01GJL1213009R00114/21BC6-30-01-P-03GJL1213009R00134/21BC6-30-01-P-04GJL1213009R00144/21BC6-30-01-P-05GJL1213009R00154/21BC6-30-01-P-07GJL1213009R00174/21BC6-30-01-P-1.4-81 GJL1213009R8011 4/26BC6-30-01-P-16GJL1213009R10164/21BC6-30-01-P-2.4-51 GJL1213009R5011 4/26BC6-30-10-01GJL1213001R01014/9BC6-30-10-03GJL1213001R01034/9BC6-30-10-04GJL1213001R01044/9BC6-30-10-05GJL1213001R01054/9BC6-30-10-07GJL1213001R01074/9BC6-30-10-1.4-81GJL1213001R81014/14BC6-30-10-16GJL1213001R11064/9BC6-30-10-2.4-51GJL1213001R51014/14BC6-30-10-F-01GJL1213003R01014/31BC6-30-10-F-03GJL1213003R01034/31BC6-30-10-F-04GJL1213003R01044/31BC6-30-10-F-05GJL1213003R01054/31BC6-30-10-F-07GJL1213003R01074/31BC6-30-10-F-1.4-81 GJL1213003R8101 4/36BC6-30-10-F-16GJL1213003R11064/31BC6-30-10-F-2.4-51 GJL1213003R5101 4/36BC6-30-10-P-01GJL1213009R01014/21BC6-30-10-P-03GJL1213009R01034/21BC6-30-10-P-04GJL1213009R01044/21BC6-30-10-P-05GJL1213009R01054/21BC6-30-10-P-07GJL1213009R01074/2114
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/20BC6-30-10-P-1.4-81 GJL1213009R8101 4/26BC6-30-10-P-16 GJL1213009R1106 4/21BC6-30-10-P-2.4-51 GJL1213009R5101 4/26BC7-30-01-01 GJL1313001R0011 4/9BC7-30-01-03 GJL1313001R0013 4/9BC7-30-01-04 GJL1313001R0014 4/9BC7-30-01-05 GJL1313001R0015 4/9BC7-30-01-07 GJL1313001R0017 4/9BC7-30-01-1.4-81 GJL1313001R8011 4/14BC7-30-01-16 GJL1313001R1016 4/9BC7-30-01-2.4-51 GJL1313001R5011 4/14BC7-30-01-F-01 GJL1313003R0011 4/31BC7-30-01-F-03 GJL1313003R0013 4/31BC7-30-01-F-04 GJL1313003R0014 4/31BC7-30-01-F-05 GJL1313003R0015 4/31BC7-30-01-F-07 GJL1313003R0017 4/31BC7-30-01-F-1.4-81 GJL1313003R8011 4/36BC7-30-01-F-16 GJL1313003R1016 4/31BC7-30-01-F-2.4-51 GJL1313003R5011 4/36BC7-30-01-P-01 GJL1313009R0011 4/21BC7-30-01-P-03 GJL1313009R0013 4/21BC7-30-01-P-04 GJL1313009R0014 4/21BC7-30-01-P-05 GJL1313009R0015 4/21BC7-30-01-P-07 GJL1313009R0017 4/21BC7-30-01-P-1.4-81 GJL1313009R8011 4/26BC7-30-01-P-16 GJL1313009R1016 4/21BC7-30-01-P-2.4-51 GJL1313009R5011 4/26BC7-30-10-01 GJL1313001R0101 4/9BC7-30-10-03 GJL1313001R1103 4/9BC7-30-10-04 GJL1313001R0104 4/9BC7-30-10-05 GJL1313001R0105 4/9BC7-30-10-07 GJL1313001R0107 4/9BC7-30-10-1.4-81 GJL1313001R8101 4/14BC7-30-10-16 GJL1313001R1106 4/9BC7-30-10-2.4-51 GJL1313001R5101 4/14BC7-30-10-F-01 GJL1313003R0101 4/31BC7-30-10-F-03 GJL1313003R0103 4/31BC7-30-10-F-04 GJL1313003R0104 4/31BC7-30-10-F-05 GJL1313003R0105 4/31BC7-30-10-F-07 GJL1313003R0107 4/31BC7-30-10-F-1.4-81 GJL1313003R8101 4/36BC7-30-10-F-16 GJL1313003R1106 4/31BC7-30-10-F-2.4-51 GJL1313003R5101 4/36BC7-30-10-P-01 GJL1313009R0101 4/21BC7-30-10-P-03 GJL1313009R0103 4/21BC7-30-10-P-04 GJL1313009R0104 4/21BC7-30-10-P-05 GJL1313009R0105 4/21BC7-30-10-P-07 GJL1313009R0107 4/21BC7-30-10-P-1.4-81 GJL1313009R8101 4/26BC7-30-10-P-16 GJL1313009R1106 4/21BC7-30-10-P-2.4-51 GJL1313009R5101 4/26BDT4 1SBN110122T1000 3/257BEA140/XT2 1SFN084206R1000 3/265BEA140/XT3 1SFN084206R1002 3/265BEA140/XT4 1SFN084206R1001 3/265BEA16-3 1SBN081006T1000 5/13BEA16-3U 1SBN081020R1000 5/61BEA16-4 1SBN030111R1000 12/8 1SBN081306T1000 3/262 1SBN081311R1000 12/8BEA16-4K 1SBN081321T1000 3/264BEA205/T4 1SFN084806R1001 3/265BEA205/XT4 1SFN084806R1000 3/265BEA26-4 1SBN010110R1010 12/7 1SBN030111R1000 12/9 1SBN082306T1000 3/262 1SBN082311R1000 12/9BEA370/T5 1SFN085406R1000 3/265BEA38-4 1SBN010110R1010 12/6 1SBN030111R1000 12/8 1SBN082306T2000 3/262 1SBN082311R1000 12/8BEA38-4K 1SBN082321T2000 3/264BEA460H/T4 1SFN085907R1000 3/265BEA65-4 1SBN010110R1001 12/8 1SBN010110R1010 12/6 1SBN033405T1000 12/8 1SBN083406R1000 3/262 1SBN083411R1000 12/8 1SBN113405R1000 12/6BEA7/132 1SBN080906R1002 4/49BEA7/325 1SBN080906R1001 4/49BEA750/T5 1SFN086106R1001 3/265BEA750/T6 1SFN086106R1000 3/265BEA750D/T5 1SFN086106R1003 3/265BEA750D/T6 1SFN086106R1002 3/265BED460 1SFN085703R1000 3/263BED580 1SFN085903R1000 3/263BED750 1SFN086103R1000 3/263BEF460/OESA400 1SFN085708R1000 3/265BEF750/OESA800 1SFN086108R1000 3/265BEM460-30 1SFN085701R1000 3/262BEM750-30 1SFN086101R1000 3/262BEP140-30 1SFN084214R1000 3/262BEP140-40 1SFN084214R2000 3/262BEP205-30 1SFN084814R1000 3/262BEP205-40 1SFN084814R2000 3/262BEP370-30 1SFN085414R1000 3/262BEP370-40 1SFN085414R2000 3/262BER140-4 1SFN030300R1000 12/37 1SFN084111R1000 12/37 1SFN084211R1000 3/262BER16-4 1SBN030111R1000 12/37 1SBN081311R1000 3/262BER16C-3 1SBN011010T1010 12/65 1SBN031005T1000 12/65 1SBN081012R1000 5/13BER205-4 1SFN030300R1000 12/37 1SFN084811R1000 3/262BER370-4 1SFN030300R1000 12/39 1SFN085411R1000 3/262BER38-4 1SBN010110R1010 12/37 1SBN030111R1000 12/37 1SBN082311R1000 3/262BER65-4 1SBN010110R1001 12/37 1SBN010110R1010 12/37 1SBN033405T1000 12/37 1SBN083411R1000 3/262BER96-4 1SBN010110R1001 12/8 1SBN010110R1010 12/8 1SBN033405T1000 12/8 1SBN083911R1000 3/262BES460 1SFN085704R1000 3/262BES750 1SFN086104R1000 3/262BEY140-4 1SFN030300R1000 12/85 1SFN084413R1000 3/263BEY16-4 1SBN030111R1000 12/85 1SBN081313R2000 3/263BEY16C-3 1SBN031005T1000 12/69 1SBN081018R2000 5/13BEY190-4 1SFN034403R1000 12/85 1SFN084813R1000 3/263BEY205-4 1SFN030300R1000 12/87 1SFN085213R1000 3/263BEY265-4 1SFN035203R1000 12/87 1SFN085413R1000 3/263BEY370-4 1SFN030300R1000 12/87 1SFN085813R1000 3/263BEY38-4 1SBN030111R1000 12/85 1SBN082713R2000 3/263BEY65-4 1SBN033405T1000 12/85 1SBN083413R2000 3/263BEY96-4 1SBN033405T1000 12/85 1SBN083913R2000 3/263BP16 1SBN111403R1000 3/285BP38-4 1SBN112303T1000 3/257BP65-4 1SBN113403T1000 3/257BP96-4 1SBN113903T1000 3/257BPR65-4 1SBN113405R1000 3/262BS1-3 1SAM201908R1001 2/41BS2-3 1SAM401921R1001 2/42BSM6-30 GJL1201908R0001 4/49BSS1000 SK829090-H 3/152BSS550 SK829090-E 3/152BX4 1SBN110108T1000 3/256BX4-CA 1SBN110109W1000 3/256C011-100 GHC0110003R0004 7/6C011-110 GHC0110003R0005 7/6C011-120 GHC0110003R0006 7/6C011-130 GHC0110003R0007 7/6C011-140 GHC0110003R0011 7/6C011-150 GHC0110003R0008 7/6C011-160 GHC0110003R0009 7/6C011-170 GHC0110003R0010 7/6C011-3-150 GHC0110033R0008 7/6C011-70 GHC0110003R0001 7/6C011-80 GHC0110003R0002 7/6C011-90 GHC0110003R0003 7/6CA3-01 1SBN011010T1001 5/13CA3-01S 1SBN011019T1001 5/61CA3-10 1SBN011010T1010 5/13CA3-10S 1SBN011019T1010 5/61CA4-01 1SBN010110R1001 3/230CA4-01K 1SBN010160R1001 3/232CA4-01K-T 1SBN010160T1001 3/232CA4-01-T 1SBN010110T1001 3/230CA4-04E 1SBN010140R1004 3/230CA4-04M 1SBN010140R1104 3/230CA4-04MK 1SBN010146R1104 3/232CA4-04N 1SBN010140R1204 3/230CA4-04NK 1SBN010146R1204 3/232CA4-10 1SBN010110R1010 3/230CA4-10K 1SBN010160R1010 3/232CA4-10K-T 1SBN010160T1010 3/232CA4-10-T 1SBN010110T1010 3/230CA4-13M 1SBN010140R1113 3/230CA4-13MK 1SBN010146R1113 3/232CA4-13N 1SBN010140R1213 3/230CA4-13NK 1SBN010146R1213 3/232CA4-22E 1SBN010140R1022 3/230CA4-22EK 1SBN010146R1022 3/232CA4-22M 1SBN010140R1122 3/230CA4-22MK 1SBN010146R1122 3/232CA4-22N 1SBN010140R1222 3/230CA4-22NK 1SBN010146R1222 3/232CA4-22U 1SBN010140R1322 3/230CA4-31E 1SBN010140R1031 3/230CA4-31EK 1SBN010146R1031 3/232CA4-31M 1SBN010140R1131 3/230CA4-31MK 1SBN010146R1131 3/232CA4-31N 1SBN010140R1231 3/23014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/21ABB MOTOR PROTECTION AND CONTROLCA4-31NK1SBN010146R1231 3/232CA4-31U1SBN010140R1331 3/230CA4-40E1SBN010140R1040 3/230CA4-40EK1SBN010146R1040 3/232CA4-40N1SBN010140R1240 3/230CA4-40NK1SBN010146R1240 3/232CA4-40U1SBN010140R1340 3/230CA5-011SBN010010R1001 3/272CA5-04E1SBN010040R1004 3/272CA5-04M1SBN010040R1104 3/272CA5-101SBN010010R1010 3/272CA5-11/11E1SBN010040R1018 3/272CA5-11/11M1SBN010040R1118 3/272CA5-13M1SBN010040R1113 3/272CA5-22E1SBN010040R1022 3/272CA5-22M1SBN010040R1122 3/272CA5-31E1SBN010040R1031 3/272CA5-31M1SBN010040R1131 3/272CA5-40E1SBN010040R1040 3/272CA6-11EGJL1201317R0002 4/49CA6-11E-FGJL1201318R0002 4/49CA6-11E-PGJL1201319R0002 4/49CA6-11KGJL1201317R0001 4/50CA6-11K-FGJL1201318R0001 4/50CA6-11K-PGJL1201319R0001 4/50CA6-11MGJL1201317R0003 4/49CA6-11M-FGJL1201318R0003 4/49CA6-11M-PGJL1201319R0003 4/49CA6-11NGJL1201317R0004 4/49CA6-11N-FGJL1201318R0004 4/49CA6-11N-PGJL1201319R0004 4/49CAF6-02EGJL1201330R0010 4/49CAF6-02KGJL1201330R0009 4/50CAF6-02MGJL1201330R0011 4/49CAF6-02NGJL1201330R0012 4/49CAF6-11EGJL1201330R0002 4/49CAF6-11KGJL1201330R0001 4/50CAF6-11MGJL1201330R0003 4/49CAF6-11NGJL1201330R0004 4/49CAF6-20EGJL1201330R0006 4/49CAF6-20KGJL1201330R0005 4/50CAF6-20MGJL1201330R0007 4/49CAF6-20NGJL1201330R0008 4/49CAL16-11ASK829002-A3/298CAL16-11BSK829002-B3/152CAL16-11CSK829002-C3/152CAL16-11DSK829002-D3/152CAL18-111SFN010720R1011 3/238CAL18-11B1SFN010720R3311 3/238CAL19-111SFN010820R1011 3/238CAL19-11B1SFN010820R3311 3/238CAL4-111SBN010120R1011 3/230CAL4-11K1SBN010134R1011 3/232CAL4-11-T1SBN010120T1011 3/230CAL5-111SBN010020R1011 3/272CAT4-11E1SBN010151R1011 3/230CAT4-11M1SBN010151R1111 3/230CAT4-11U1SBN010151R1311 3/230CB5-011SBN010013R1001 3/250CB5-101SBN010013R1010 3/250CC4-011SBN010111R1001 3/230CC4-101SBN010111R1010 3/230CC5-011SBN010011R1001 3/272CC5-101SBN010011R1010 3/272CCL16-11E SK829002-E 3/152CCL16-11E SK829002-E 3/298CDP18.1501SAJ929180R0015 11/12CDP23.1501SAJ929230R0015 11/14CDP23.3001SAJ929230R0030 11/14CDP24.1501SAJ929240R0015 11/12CE5-01D0.11SBN010015R1001 3/234CE5-01D21SBN010017R1001 3/234CE5-01W0.11SBN010016R1001 3/234CE5-01W21SBN010018R1001 3/234CE5-10D0.11SBN010015R1010 3/234CE5-10D21SBN010017R1010 3/234CE5-10W0.11SBN010016R1010 3/234CE5-10W21SBN010018R1010 3/234CEL18-011SFN010716R1001 3/240CEL18-101SFN010716R1010 3/240CEL19-011SFN010832R1001 3/240CEL19-101SFN010832R1010 3/240CEM11-FBP.1201SAJ929200R0120 11/16CEM11-FBP.201SAJ929200R0020 11/16CEM11-FBP.351SAJ929200R0035 11/16CEM11-FBP.601SAJ929200R0060 11/16CK1-021SAM301901R1003 2/35CK1-111SAM301901R1001 2/35CK1-201SAM301901R1002 2/35CM-MSE1SVR550800R9300 7/51SVR550801R9300 7/51SVR550805R9300 7/5CM-MSS.11P1SVR740720R1400 7/5CM-MSS.11S1SVR730720R1400 7/5CM-MSS.12P1SVR740700R0100 7/5CM-MSS.12S1SVR730700R0100 7/5CM-MSS.13P1SVR740700R2100 7/5CM-MSS.13S1SVR730700R2100 7/5CM-MSS.21P1SVR740722R1400 7/5CM-MSS.21S1SVR730722R1400 7/5CM-MSS.22P1SVR740700R0200 7/5CM-MSS.22S1SVR730700R0200 7/5CM-MSS.23P1SVR740700R2200 7/5CM-MSS.23S1SVR730700R2200 7/5CM-MSS.31P1SVR740712R14007/5CM-MSS.31S1SVR730712R14007/5CM-MSS.32P1SVR740712R0200 7/5CM-MSS.32S1SVR730712R0200 7/5CM-MSS.33P1SVR740712R22007/5CM-MSS.33S1SVR730712R22007/5CM-MSS.41P1SVR740712R12007/5CM-MSS.41S1SVR730712R12007/5CM-MSS.51P1SVR740712R13007/5CM-MSS.51S1SVR730712R13007/5CT4L185R/41SAJ929500R0185 11/16CT4L310R/41SAJ929500R0310 11/16CT5L500R/41SAJ929501R0500 11/16CT5L850R/41SAJ929501R0850 11/16CT-ERS.21S1SBN020112R1000 12/851SVR730100R0300 12/85CT-SDS.22S1SVR730210R3300 12/69CT-SDS.23S1SVR730211R2300 12/69DB161SAZ701901R0001 6/4DB16E1SAX101110R0001 6/29DB19EF1SAX101910R1001 6/29DB2001SAZ401110R0001 6/25DB421SAZ701902R0001 6/9DB45EF1SAX201910R0001 6/29DB651SAZ801901R1001 6/13DB961SAZ901901R1001 6/17DMS132-G1SAM201912R1010 2/44DMS132-Y1SAM201912R1011 2/44DNP31.01SAJ231000R0001 11/11DRAF09-11S1SBK134237R1100 9/8DRAF09-11U1SBK134238R1100 9/8DRAF09-13N1SBK134137R13009/8DRAF09-13U1SBK134238R1300 9/8DRAF09-14P1SBK134037R1400 9/8DRAF09-14U1SBK134238R1400 9/8DRAF12-11S1SBK154237R1100 9/8DRAF12-11U1SBK154238R1100 9/8DRAF12-13N1SBK154137R1300 9/8DRAF12-13U1SBK154238R1300 9/8DRAF12-14P1SBK154037R1400 9/8DRAF12-14U1SBK154238R1400 9/8DRAF16-11S1SBK174237R11009/8DRAF16-11U1SBK174238R1100 9/8DRAF16-13N1SBK174137R13009/8DRAF16-13U1SBK174238R1300 9/8DRAF16-14P1SBK174037R1400 9/8DRAF16-14U1SBK174238R1400 9/8DRAS09-20S1SBK104235R2000 9/2DRAS09-26N1SBK104135R2600 9/2DRAS09-27N1SBK104135R2700 9/2DRAS09-28P1SBK104035R2800 9/2DRAS09-29P1SBK104035R2900 9/2DRAS12-20S1SBK114235R2000 9/2DRAS12-26N1SBK114135R2600 9/2DRAS12-27N1SBK114135R27009/2DRAS12-28P1SBK114035R2800 9/2DRAS12-29P1SBK114035R2900 9/2DRAS16-20S1SBK124235R2000 9/2DRAS16-26N1SBK124135R2600 9/2DRAS16-27N1SBK124135R2700 9/2DRAS16-28P1SBK124035R2800 9/2DRAS16-29P1SBK124035R2900 9/2DRASL09-81S1SBK104335R81009/2DRASL09-83S1SBK104335R83009/2DRASL12-81S1SBK114335R81009/2DRASL12-83S1SBK114335R83009/2DRASL16-81S1SBK124335R81009/2DRASL16-83S1SBK124335R83009/2DRS-F-011SAX101911R1001 6/9DRS-F-021SAX101911R1002 6/9DRS-F-031SAX101911R1003 6/9DRS-F-041SAX101911R1004 6/9DT500/AF460-L1SAX701902R10016/41DT500/AF460-S1SAX701902R10116/41DT800/AF750-L1SAX801902R10016/41DT800/AF750-S1SAX801902R10116/41DX111-FBP.01SAJ611000R0101 11/10DX122-FBP.01SAJ622000R0101 11/10E16DU-0.321SAX111001R1101 6/29E16DU-1.01SAX111001R1102 6/29E16DU-18.91SAX111001R1105 6/29E16DU-2.71SAX111001R1103 6/29E16DU-6.31SAX111001R1104 6/29EF1250DU-12501SFA739001R10016/41EF146-1501SAX351001R1101 6/33EF19-0.321SAX121001R1101 6/29EF19-1.01SAX121001R1102 6/29EF19-18.91SAX111001R1105 12/381SAX121001R1105 6/29EF19-2.71SAX121001R1103 6/29EF19-6.31SAX121001R1104 6/29EF205-1101SAX531001R1101 12/38EF205-2101SAX531001R1101 6/37EF370-3801SAX611001R1101 6/37EF45-301SAX211001R1101 12/381SAX221001R1101 6/29EF45-451SAX211001R1102 12/381SAX221001R1102 6/29EF460-5001SAX721001R1101 6/4114
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/22EF65-56 1SAX331001R1102 6/33EF65-70 1SAX331001R1101 6/33EF750-800 1SAX821001R1101 6/41EF96-100 1SAX341001R1101 6/33EF96-56 1SAX341001R1102 6/33EIU32.0 1SAJ262000R0100 11/13EK1000-40-11 SK827044-AD 3/148 SK827044-AR 3/148 SK827044-EF 3/148 SK827044-EG 3/148 SK827044-EL 3/148 SK827044-EM 3/148EK1000-40-21 SK827044-DB 3/149 SK827044-DC 3/149 SK827044-DD 3/149 SK827044-DE 3/149 SK827044-DF 3/149 SK827044-DG 3/149 SK827044-DT 3/149 SK827044-DU 3/149EK1000-40-22 SK827045-AD 3/150 SK827045-AR 3/150 SK827045-EF 3/150 SK827045-EG 3/150 SK827045-EL 3/150 SK827045-EM 3/150 SK827045-EP 3/150 SK827045-ER 3/150EK550-40-11 SK827041-AD 3/148 SK827041-AR 3/148 SK827041-EF 3/148 SK827041-EG 3/148 SK827041-EL 3/148 SK827041-EM 3/148EK550-40-21 SK827041-DB 3/149 SK827041-DD 3/149 SK827041-DE 3/149 SK827041-DF 3/149 SK827041-DG 3/149 SK827041-DU 3/149EK550-40-22 SK827043-AD 3/150 SK827043-AR 3/150 SK827043-EF 3/150 SK827043-EG 3/150 SK827043-EL 3/150 SK827043-EM 3/150Ekip M-LIU In160 1SDA067355R1 12/21ETHTB-FBP.4 1SAJ929200R0001 11/14ETHTB-FBP.50 1SAJ929200R0002 11/14FR16AF-12 1SBN101337R1000 9/9FR16AF-12U 1SBN101338R1000 9/9FR16AS-12VARS 1SBN101035R1000 9/2FS116 1SAM201909R1001 2/41GA75-10-00 1SBL411025R8000 3/178 1SBL411025R8100 3/178 1SBL411025R8300 3/178 1SBL411025R8400 3/178 1SBL411025R8500 3/178 1SBL411025R8600 3/178 1SBL411025R8800 3/178GA75-10-11 1SBL411025R8011 3/178 1SBL411025R8111 3/178 1SBL411025R8311 3/178 1SBL411025R8411 3/178 1SBL411025R8511 3/178 1SBL411025R8611 3/178 1SBL411025R8811 3/178GAE75-10-00 1SBL419025R8000 3/179 1SBL419025R8100 3/179 1SBL419025R8300 3/179 1SBL419025R8600 3/179 1SBL419025R8700 3/179 1SBL419025R8800 3/179 1SBL419025R8900 3/179GAE75-10-11 1SBL419025R8011 3/179 1SBL419025R8111 3/179 1SBL419025R8311 3/179 1SBL419025R8611 3/179 1SBL419025R8711 3/179 1SBL419025R8811 3/179 1SBL419025R8911 3/179GAF1250-10-11 1SFL647025R6811 3/182 1SFL647025R6911 3/182 1SFL647025R7011 3/182 1SFL647025R7111 3/182GAF1650-10-11 1SFL677025R7011 3/182GAF185-10-11 1SFL497025R6911 3/180 1SFL497025R7011 3/180GAF185-10-11 1SFL497025R7211 3/180GAF2050-10-11 1SFL707025R7011 3/182GAF300-10-11 1SFL557025R6911 3/180 1SFL557025R7011 3/180GAF300-10-11 1SFL557025R7211 3/180GAF460-10-11 1SFL597025R6911 3/181 1SFL597025R7011 3/181 1SFL597025R7111 3/181GAF460-10-11 1SFL597025R6811 3/181GAF750-10-11 1SFL637025R6911 3/181 1SFL637025R7011 3/181 1SFL637025R7111 3/181GAF750-10-11 1SFL637025R6811 3/181HF0.6-DOL-24VDC 1SAT112000R1011 10/8HF0.6-DOLE-24VDC 1SAT113000R1011 10/8HF0.6-ROL-24VDC 1SAT115000R1011 10/9HF0.6-ROLE-24VDC 1SAT116000R1011 10/9HF2.4-DOL-24VDC 1SAT122000R1011 10/8HF2.4-DOLE-24VDC 1SAT123000R1011 10/8HF2.4-ROL-24VDC 1SAT125000R1011 10/9HF2.4-ROLE-24VDC 1SAT126000R1011 10/9HF9-DOL-24VDC 1SAT142000R1011 10/8HF9-DOLE-24VDC 1SAT143000R1011 10/8HF9-R-24VDC 1SAT144000R1011 10/9HF9-ROL-24VDC 1SAT145000R1011 10/9HF9-ROLE-24VDC 1SAT146000R1011 10/9HK1-02 1SAM201902R1003 2/35HK1-02K 1SAM201902R1203 2/37HK1-11 1SAM201902R1001 2/35HK1-11K 1SAM201902R1201 2/37HK1-20 1SAM201902R1002 2/35HK1-20K 1SAM201902R1202 2/37HK1-20L 1SAM201902R1004 2/35HK1-20LK 1SAM201902R1204 2/37HKF1-01 1SAM201901R1004 2/35HKF1-10 1SAM201901R1003 2/35HKF1-11 1SAM201901R1001 2/35HKF1-11K 1SAM201901R1201 2/37HKF1-20 1SAM201901R1002 2/35HKF1-20K 1SAM201901R1202 2/37HTP500-BA4 1SNA235712R2400 3/256IB132-G 1SAM201911R1010 2/44IB132-Y 1SAM201911R1011 2/44IOIO-CAB.030 1SAJ692000R0001 11/10K6-22Z-01 GJH1211001R0221 4/17K6-22Z-02 GJH1211001R0222 4/17K6-22Z-03 GJH1211001R0223 4/17K6-22Z-80 GJH1211001R8220 4/17K6-22Z-84 GJH1211001R8224 4/17K6-22Z-85 GJH1211001R8225 4/17K6-22Z-F-01 GJH1211003R0221 4/37K6-22Z-F-02 GJH1211003R0222 4/37K6-22Z-F-03 GJH1211003R0223 4/37K6-22Z-F-80 GJH1211003R8220 4/37K6-22Z-F-84 GJH1211003R8224 4/37K6-22Z-F-85 GJH1211003R8225 4/37K6-22Z-P-01 GJH1211009R0221 4/27K6-22Z-P-02 GJH1211009R0222 4/27K6-22Z-P-03 GJH1211009R0223 4/27K6-22Z-P-80 GJH1211009R8220 4/27K6-22Z-P-84 GJH1211009R8224 4/27K6-22Z-P-85 GJH1211009R8225 4/27K6-31Z-01 GJH1211001R0311 4/17K6-31Z-02 GJH1211001R0312 4/17K6-31Z-03 GJH1211001R0313 4/17K6-31Z-80 GJH1211001R8310 4/17K6-31Z-84 GJH1211001R8314 4/17K6-31Z-85 GJH1211001R8315 4/17K6-31Z-F-01 GJH1211003R0311 4/37K6-31Z-F-02 GJH1211003R0312 4/37K6-31Z-F-03 GJH1211003R0313 4/37K6-31Z-F-80 GJH1211003R8310 4/37K6-31Z-F-84 GJH1211003R8314 4/37K6-31Z-F-85 GJH1211003R8315 4/37K6-31Z-P-01 GJH1211009R0311 4/27K6-31Z-P-02 GJH1211009R0312 4/27K6-31Z-P-03 GJH1211009R0313 4/27K6-31Z-P-80 GJH1211009R8310 4/27K6-31Z-P-84 GJH1211009R8314 4/27K6-31Z-P-85 GJH1211009R8315 4/27K6-40E-01 GJH1211001R0401 4/17K6-40E-02 GJH1211001R0402 4/17K6-40E-03 GJH1211001R0403 4/17K6-40E-80 GJH1211001R8400 4/17K6-40E-84 GJH1211001R8404 4/17K6-40E-85 GJH1211001R8405 4/17K6-40E-F-01 GJH1211003R0401 4/37K6-40E-F-02 GJH1211003R0402 4/37K6-40E-F-03 GJH1211003R0403 4/37K6-40E-F-80 GJH1211003R8400 4/37K6-40E-F-84 GJH1211003R8404 4/37K6-40E-F-85 GJH1211003R8405 4/37K6-40E-P-01 GJH1211009R0401 4/27K6-40E-P-02 GJH1211009R0402 4/27K6-40E-P-03 GJH1211009R0403 4/27K6-40E-P-80 GJH1211009R8400 4/27K6-40E-P-84 GJH1211009R8404 4/27K6-40E-P-85 GJH1211009R8405 4/27K6S-22Z-1.7-71 GJH1213001R7221 4/19K6S-22Z-2.8-72 GJH1213001R7222 4/19K6S-31Z-1.7-71 GJH1213001R7311 4/19K6S-31Z-2.8-72 GJH1213001R7312 4/19K6S-40E-1.7-71 GJH1213001R7401 4/19K6S-40E-2.8-72 GJH1213001R7402 4/19KA165 1SAM401922R1001 2/42KC6-22Z-01 GJH1213001R0221 4/18KC6-22Z-03 GJH1213001R0223 4/18KC6-22Z-04 GJH1213001R0224 4/18KC6-22Z-05 GJH1213001R0225 4/18KC6-22Z-07 GJH1213001R0227 4/18KC6-22Z-16 GJH1213001R1226 4/18KC6-22Z-F-01 GJH1213003R0221 4/38KC6-22Z-F-04 GJH1213003R0224 4/3814
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/23ABB MOTOR PROTECTION AND CONTROLKC6-22Z-F-05GJH1213003R0225 4/38KC6-22Z-F-07GJH1213003R0227 4/38KC6-22Z-F-16GJH1213003R1226 4/38KC6-22Z-P-01GJH1213009R0221 4/28KC6-22Z-P-04GJH1213009R0224 4/28KC6-22Z-P-05GJH1213009R0225 4/28KC6-22Z-P-07GJH1213009R0227 4/28KC6-22Z-P-16GJH1213009R1226 4/28KC6-31Z-01GJH1213001R0311 4/18KC6-31Z-03GJH1213001R0313 4/18KC6-31Z-04GJH1213001R0314 4/18KC6-31Z-05GJH1213001R0315 4/18KC6-31Z-07GJH1213001R0317 4/18KC6-31Z-1.4-81GJH1213001R83114/19KC6-31Z-16GJH1213001R1316 4/18KC6-31Z-2.4-51GJH1213001R53114/19KC6-31Z-F-01GJH1213003R0311 4/38KC6-31Z-F-04GJH1213003R0314 4/38KC6-31Z-F-05GJH1213003R0315 4/38KC6-31Z-F-07GJH1213003R0317 4/38KC6-31Z-F-1.4-81GJH1213003R83114/39KC6-31Z-F-16GJH1213003R1316 4/38KC6-31Z-F-51GJH1213003R5311 4/39KC6-31Z-P-01GJH1213009R0311 4/28KC6-31Z-P-04GJH1213009R0314 4/28KC6-31Z-P-05GJH1213009R0315 4/28KC6-31Z-P-1.4-81GJH1213009R83114/29KC6-31Z-P-16GJH1213009R1316 4/28KC6-31Z-P-2.4-51GJH1213009R53114/29KC6-40E-01GJH1213001R0401 4/18KC6-40E-03GJH1213001R0403 4/18KC6-40E-04GJH1213001R0404 4/18KC6-40E-05GJH1213001R0405 4/18KC6-40E-07GJH1213001R0407 4/18KC6-40E-1.4-81GJH1213001R84014/19KC6-40E-16GJH1213001R1406 4/18KC6-40E-2.4-51GJH1213001R54014/19KC6-40E-F-01GJH1213003R0401 4/38KC6-40E-F-04GJH1213003R0404 4/38KC6-40E-F-05GJH1213003R0405 4/38KC6-40E-F-1.4-81GJH1213003R84014/39KC6-40E-F-16GJH1213003R1406 4/38KC6-40E-F-51GJH1213003R5401 4/39KC6-40E-P-01GJH1213009R0401 4/28KC6-40E-P-04GJH1213009R0404 4/28KC6-40E-P-05GJH1213009R0405 4/28KC6-40E-P-07GJH1213009R0407 4/28KC6-40E-P-1.4-81GJH1213009R84014/29KC6-40E-P-16GJH1213009R1406 4/28KC6-40E-P-2.4-51GJH1213009R54014/29KH800SK828100-AD 3/306SK828100-AR 3/306SK828100-EF 3/306SK828100-EG 3/306SK828100-EL 3/306SK828100-EM 3/306SK828100-ER 3/306KM1 : 1 x CA4-10 1SBN010110R1010 12/85KM1 : 1 x CA4-10 1SBN010110R1001 12/851SBN010110R1010 12/85KM1: 1 x CA3-10 1SBN011010T1010 12/69KP800SK828150-DB 3/306SK828150-DE 3/306SK828150-DF 3/306SK828150-DU 3/306KPR-101L1SFA616162R1014 6/4KWK10005223351-AN3/305KWK5505223351-Z3/305KZK1000SK827204-F3/305KZK550SK827204-B3/305LB6GJL1201902R0001 4/49LB6-CAGJL1201903R0001 4/49LD146-301SFN074208R1000 3/260LD146-401SFN074208R2000 3/260LD38-41SBN072308R1000 3/258LD751SBN073508R1000 3/292LDC41SBN070156T1000 3/256LDC4K1SBN070159T1000 3/256LE4601SFN075716R1000 3/260LE7501SFN076116R1000 3/260LF16-41SBN071305R1000 3/261LF38-41SBN072305R1000 3/261LG16-41SBN071306R1000 3/261LH38-41SBN072304R1000 3/261LK75-F1SBN073552R1002 3/293LK75-L1SBN073552R1003 3/293LL146-301SFN074211R1000 3/260LL146-401SFN074211R2000 3/260LL205-301SFN074811R1000 3/260LL205-401SFN074811R2000 3/260LL370-301SFN075411R1000 3/260LL370-401SFN075411R2000 3/260LP12501SFN076412R1000 3/294LP1851SFN074712R1000 3/261LP20501SFN076512R1000 3/294LP3001SFN075112R1000 3/261LP4601SFN075712R1000 3/261LP6GJL1201907R0001 4/49LP7501SFN076112R1000 3/261LT1000-EKSK178001-MB3/302LT140-30L1SFN124203R1000 3/259LT140-40L1SFN124203R2000 3/259LT200/A1SAZ401901R1001 6/25LT200E1SAX501904R0001 6/37LT205-30C1SFN124801R1000 3/259LT205-30L1SFN124803R1000 3/259LT205-30Y1SFN124804R1000 3/259LT205-40C1SFN124801R2000 3/259LT205-40L1SFN124803R2000 3/259LT320E1SAX601904R0001 6/37LT370-30C1SFN125401R1000 3/259LT370-30D1SFN125406R1000 3/259LT370-30L1SFN125403R1000 3/259LT370-30Y1SFN125404R1000 3/259LT370-40C1SFN125401R2000 3/259LT370-40L1SFN125403R2000 3/259LT460-AC1SFN125701R1000 3/259LT460-AL1SFN125703R1000 3/259LT460EF1SAX701904R0002 6/41LT52-401SBN123402R1000 3/259LT550-EKSK178001-LB3/302LT65-301SBN123401R1000 3/259LT6-BGJL1201906R0001 4/49LT750-AC1SFN126101R1000 3/259LT750-AL1SFN126103R1000 3/259LT750EF1SAX801904R0002 6/41LT80-401SBN123902R1000 3/259LT96-301SBN123901R1000 3/259LW1101SFN074307R1000 3/292LW12501SFN076407R1000 3/260LW1401SFN074207R1000 3/260LW2051SFN074807R1000 3/260LW205-401SFN074807R2000 3/260LW3701SFN075407R1000 3/260LW370-401SFN075407R2000 3/260LW4601SFN075707R1000 3/260LW7501SFN076107R1000 3/260LX1401SFN074210R1000 3/260LX2051SFN074810R1000 3/260LX3701SFN075410R1000 3/260LX4601SFN075710R1000 3/260LX7501SFN076110R1000 3/260LY1401SFN074203R1000 3/261LY16-41SBN071303T1000 3/261LY1851SFN074703R1000 3/261LY3001SFN075103R1000 3/261LY38-41SBN072303T1000 3/261LY4601SFN075703R1000 3/261LY7501SFN076103R1000 3/261MO132-0.161SAM360000R1001 2/14MO132-0.251SAM360000R1002 2/14MO132-0.41SAM360000R1003 2/14MO132-0.631SAM360000R1004 2/14MO132-1.01SAM360000R1005 2/14MO132-1.61SAM360000R1006 2/14MO132-101SAM360000R1010 2/14MO132-121SAM360000R1012 2/14MO132-161SAM360000R1011 2/14MO132-2.51SAM360000R1007 2/14MO132-201SAM360000R1013 2/14MO132-251SAM360000R1014 2/14MO132-321SAM360000R1015 2/14MO132-4.01SAM360000R1008 2/14MO132-6.31SAM360000R1009 2/14MO165-161SAM461000R1011 2/15MO165-201SAM461000R1012 2/15MO165-251SAM461000R1013 2/15MO165-321SAM461000R1014 2/15MO165-421SAM461000R1015 2/15MO165-541SAM461000R1016 2/15MO165-651SAM461000R1017 2/15MO165-731SAM461000R1018 2/15MO165-801SAM461000R1019 2/15MRP31.01SAJ251000R0001 11/11MS116-0.161SAM250000R1001 2/10MS116-0.16-HKF1-11 1SAM250005R1001 2/10MS116-0.251SAM250000R1002 2/10MS116-0.25-HKF1-11 1SAM250005R1002 2/10MS116-0.41SAM250000R1003 2/10MS116-0.4-HKF1-11 1SAM250005R1003 2/10MS116-0.631SAM250000R1004 2/10MS116-0.63-HKF1-11 1SAM250005R1004 2/10MS116-1.01SAM250000R1005 2/10MS116-1.0-HKF1-11 1SAM250005R1005 2/10MS116-1.61SAM250000R1006 2/10MS116-1.6-HKF1-11 1SAM250005R1006 2/10MS116-101SAM250000R1010 2/10MS116-10.0-HKF1-11 1SAM250005R1010 2/10MS116-121SAM250000R1012 2/10MS116-12.0-HKF1-11 1SAM250005R1012 2/10MS116-161SAM250000R1011 2/10MS116-16.0-HKF1-11 1SAM250005R1011 2/10MS116-2.51SAM250000R1007 2/10MS116-2.5-HKF1-11 1SAM250005R1007 2/10MS116-201SAM250000R1013 2/10MS116-20-HKF1-11 1SAM250005R1013 2/10MS116-251SAM250000R1014 2/10MS116-25-HKF1-11 1SAM250005R1014 2/10MS116-321SAM250000R1015 2/10MS116-32-HKF1-11 1SAM250005R1015 2/10MS116-4.01SAM250000R1008 2/1014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/24MS116-4.0-HKF1-11 1SAM250005R1008 2/10MS116-6.3 1SAM250000R1009 2/10MS116-6.3-HKF1-11 1SAM250005R1009 2/10MS132-0.16 1SAM350000R1001 2/11MS132-0.16-HKF1-11 1SAM350005R1001 2/11MS132-0.16K 1SAM350010R1001 2/12MS132-0.16KT 1SAM340010R1001 2/30MS132-0.16T 1SAM340000R1001 2/29MS132-0.25 1SAM350000R1002 2/11MS132-0.25-HKF1-11 1SAM350005R1002 2/11MS132-0.25K 1SAM350010R1002 2/12MS132-0.25KT 1SAM340010R1002 2/30MS132-0.25T 1SAM340000R1002 2/29MS132-0.4 1SAM350000R1003 2/11MS132-0.4-HKF1-11 1SAM350005R1003 2/11MS132-0.4K 1SAM350010R1003 2/12MS132-0.4KT 1SAM340010R1003 2/30MS132-0.4T 1SAM340000R1003 2/29MS132-0.63 1SAM350000R1004 2/11MS132-0.63-HKF1-11 1SAM350005R1004 2/11MS132-0.63K 1SAM350010R1004 2/12MS132-0.63KT 1SAM340010R1004 2/30MS132-0.63T 1SAM340000R1004 2/29MS132-1.0 1SAM350000R1005 2/11MS132-1.0-HKF1-11 1SAM350005R1005 2/11MS132-1.0K 1SAM350010R1005 2/12MS132-1.0KT 1SAM340010R1005 2/30MS132-1.0T 1SAM340000R1005 2/29MS132-1.6 1SAM350000R1006 2/11MS132-1.6-HKF1-11 1SAM350005R1006 2/11MS132-1.6K 1SAM350010R1006 2/12MS132-1.6KT 1SAM340010R1006 2/30MS132-1.6T 1SAM340000R1006 2/29MS132-10 1SAM350000R1010 2/11MS132-10.0-HKF1-11 1SAM350005R1010 2/11MS132-10K 1SAM350010R1010 2/12MS132-10KT 1SAM340010R1010 2/30MS132-10T 1SAM340000R1010 2/29MS132-12 1SAM350000R1012 2/11MS132-12.0-HKF1-11 1SAM350005R1012 2/11MS132-12T 1SAM340000R1012 2/29MS132-16 1SAM350000R1011 2/11MS132-16.0-HKF1-11 1SAM350005R1011 2/11MS132-16-HKF1-20 1SAM350006R1011 2/11MS132-16K 1SAM350010R1011 2/12MS132-16KT 1SAM340010R1011 2/30MS132-16T 1SAM340000R1011 2/29MS132-2.5 1SAM350000R1007 2/11MS132-2.5-HKF1-11 1SAM350005R1007 2/11MS132-2.5K 1SAM350010R1007 2/12MS132-2.5KT 1SAM340010R1007 2/30MS132-2.5T 1SAM340000R1007 2/29MS132-20 1SAM350000R1013 2/11MS132-20-HKF1-11 1SAM350005R1013 2/11MS132-20K 1SAM350010R1013 2/12MS132-20KT 1SAM340010R1013 2/30MS132-20T 1SAM340000R1013 2/29MS132-25 1SAM350000R1014 2/11MS132-25-HKF1-11 1SAM350005R1014 2/11MS132-25K 1SAM350010R1014 2/12MS132-25KT 1SAM340010R1014 2/30MS132-25T 1SAM340000R1014 2/29MS132-32 1SAM350000R1015 2/11MS132-32-HKF1-11 1SAM350005R1015 2/11MS132-32K 1SAM350010R1015 2/12MS132-4.0 1SAM350000R1008 2/11MS132-4.0-HKF1-11 1SAM350005R1008 2/11MS132-4.0K 1SAM350010R1008 2/12MS132-4.0KT 1SAM340010R1008 2/30MS132-4.0T 1SAM340000R1008 2/29MS132-6.3 1SAM350000R1009 2/11MS132-6.3-HKF1-11 1SAM350005R1009 2/11MS132-6.3K 1SAM350010R1009 2/12MS132-6.3KT 1SAM340010R1009 2/30MS132-6.3T 1SAM340000R1009 2/29MS165-16 1SAM451000R1011 2/13MS165-20 1SAM451000R1012 2/13MS165-25 1SAM451000R1013 2/13MS165-32 1SAM451000R1014 2/13MS165-42 1SAM451000R1015 2/13MS165-54 1SAM451000R1016 2/13MS165-65 1SAM451000R1017 2/13MS165-73 1SAM451000R1018 2/13MS165-80 1SAM451000R1019 2/13MS495-75 1SAM550000R1008 12/6MS495-90 1SAM550000R1009 12/6MSAH1 1SAM201909R1021 2/45MSH-AR 1SAM201920R1000 2/45MSHD-LB 1SAM201920R1001 2/45MSHD-LTB 1SAM201920R1011 2/45MSHD-LTY 1SAM201920R1012 2/45MSHD-LY 1SAM201920R1002 2/45MSMN 1SAM101923R0002 2/45MSMNO 1SAM101923R0012 2/45MTQ22-FBP.0 1SAJ260000R0100 11/13NF22E-11 1SBH137001R1122 3/208NF22E-12 1SBH137001R1222 3/208NF22E-13 1SBH137001R1322 3/208NF22E-14 1SBH137001R1422 3/208NF22EK-11 1SBH137005R1122 3/219NF22EK-12 1SBH137005R1222 3/219NF22EK-13 1SBH137005R1322 3/219NF22EK-14 1SBH137005R1422 3/219NF31E-11 1SBH137001R1131 3/208NF31E-12 1SBH137001R1231 3/208NF31E-13 1SBH137001R1331 3/208NF31E-14 1SBH137001R1431 3/208NF31EK-11 1SBH137005R1131 3/219NF31EK-12 1SBH137005R1231 3/219NF31EK-13 1SBH137005R1331 3/219NF31EK-14 1SBH137005R1431 3/219NF33/11-11 1SBH137001R1139 3/212NF33/11-12 1SBH137001R1239 3/212NF33/11-13 1SBH137001R1339 3/212NF33/11-14 1SBH137001R1439 3/212NF40E-11 1SBH137001R1140 3/208NF40E-12 1SBH137001R1240 3/208NF40E-13 1SBH137001R1340 3/208NF40E-14 1SBH137001R1440 3/208NF40EK-11 1SBH137005R1140 3/219NF40EK-12 1SBH137005R1240 3/219NF40EK-13 1SBH137005R1340 3/219NF40EK-14 1SBH137005R1440 3/219NF44E-11 1SBH137001R1144 3/212NF44E-12 1SBH137001R1244 3/212NF44E-13 1SBH137001R1344 3/212NF44E-14 1SBH137001R1444 3/212NF44EK-11 1SBH137005R1144 3/219NF44EK-12 1SBH137005R1244 3/219NF44EK-13 1SBH137005R1344 3/219NF44EK-14 1SBH137005R1444 3/219NF51/11-11 1SBH137001R1159 3/212NF51/11-12 1SBH137001R1259 3/212NF51/11-13 1SBH137001R1359 3/212NF51/11-14 1SBH137001R1459 3/212NF53E-11 1SBH137001R1153 3/212NF53E-12 1SBH137001R1253 3/212NF53E-13 1SBH137001R1353 3/212NF53E-14 1SBH137001R1453 3/212NF53EK-11 1SBH137005R1153 3/219NF53EK-12 1SBH137005R1253 3/219NF53EK-13 1SBH137005R1353 3/219NF53EK-14 1SBH137005R1453 3/219NF62E-11 1SBH137001R1162 3/212NF62E-12 1SBH137001R1262 3/212NF62E-13 1SBH137001R1362 3/212NF62E-14 1SBH137001R1462 3/212NF62EK-11 1SBH137005R1162 3/219NF62EK-12 1SBH137005R1262 3/219NF62EK-13 1SBH137005R1362 3/219NF62EK-14 1SBH137005R1462 3/219NF71E-11 1SBH137001R1171 3/212NF71E-12 1SBH137001R1271 3/212NF71E-13 1SBH137001R1371 3/212NF71E-14 1SBH137001R1471 3/212NF71EK-11 1SBH137005R1171 3/219NF71EK-12 1SBH137005R1271 3/219NF71EK-13 1SBH137005R1371 3/219NF71EK-14 1SBH137005R1471 3/219NF80E-11 1SBH137001R1180 3/212NF80E-12 1SBH137001R1280 3/212NF80E-13 1SBH137001R1380 3/212NF80E-14 1SBH137001R1480 3/212NF80EK-11 1SBH137005R1180 3/219NF80EK-12 1SBH137005R1280 3/219NF80EK-13 1SBH137005R1380 3/219NF80EK-14 1SBH137005R1480 3/219NFZ22E-20 1SBH136001R2022 3/210NFZ22E-21 1SBH136001R2122 3/210NFZ22E-22 1SBH136001R2222 3/210NFZ22E-23 1SBH136001R2322 3/210NFZ22E-30 1SBH136001R3022 3/209NFZ22EK-20 1SBH136005R2022 3/221NFZ22EK-21 1SBH136005R2122 3/221NFZ22EK-22 1SBH136005R2222 3/221NFZ22EK-23 1SBH136005R2322 3/221NFZ22EK-30 1SBH136005R3022 3/220NFZ31E-20 1SBH136001R2031 3/210NFZ31E-21 1SBH136001R2131 3/210NFZ31E-22 1SBH136001R2231 3/210NFZ31E-23 1SBH136001R2331 3/210NFZ31E-30 1SBH136001R3031 3/209NFZ31EK-20 1SBH136005R2031 3/221NFZ31EK-21 1SBH136005R2131 3/221NFZ31EK-22 1SBH136005R2231 3/221NFZ31EK-23 1SBH136005R2331 3/221NFZ31EK-30 1SBH136005R3031 3/220NFZ33/11-20 1SBH136001R2039 3/214NFZ33/11-21 1SBH136001R2139 3/214NFZ33/11-22 1SBH136001R2239 3/214NFZ33/11-23 1SBH136001R2339 3/214NFZ40E-20 1SBH136001R2040 3/210NFZ40E-21 1SBH136001R2140 3/210NFZ40E-22 1SBH136001R2240 3/210NFZ40E-23 1SBH136001R2340 3/210NFZ40E-30 1SBH136001R3040 3/209NFZ40EK-20 1SBH136005R2040 3/221NFZ40EK-21 1SBH136005R2140 3/221NFZ40EK-22 1SBH136005R2240 3/221NFZ40EK-23 1SBH136005R2340 3/221NFZ40EK-30 1SBH136005R3040 3/22014
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/25ABB MOTOR PROTECTION AND CONTROLNFZ44E-201SBH136001R2044 3/214NFZ44E-211SBH136001R2144 3/214NFZ44E-221SBH136001R2244 3/214NFZ44E-231SBH136001R2344 3/214NFZ44E-301SBH136001R3044 3/213NFZ44EK-201SBH136005R2044 3/221NFZ44EK-211SBH136005R2144 3/221NFZ44EK-221SBH136005R2244 3/221NFZ44EK-231SBH136005R2344 3/221NFZ44EK-301SBH136005R3044 3/220NFZ51/11-201SBH136001R2059 3/214NFZ51/11-211SBH136001R2159 3/214NFZ51/11-221SBH136001R2259 3/214NFZ51/11-231SBH136001R2359 3/214NFZ53E-201SBH136001R2053 3/214NFZ53E-211SBH136001R2153 3/214NFZ53E-221SBH136001R2253 3/214NFZ53E-231SBH136001R2353 3/214NFZ53E-301SBH136001R3053 3/213NFZ53EK-201SBH136005R2053 3/221NFZ53EK-211SBH136005R2153 3/221NFZ53EK-221SBH136005R2253 3/221NFZ53EK-231SBH136005R2353 3/221NFZ53EK-301SBH136005R3053 3/220NFZ62E-201SBH136001R2062 3/214NFZ62E-211SBH136001R2162 3/214NFZ62E-221SBH136001R2262 3/214NFZ62E-231SBH136001R2362 3/214NFZ62E-301SBH136001R3062 3/213NFZ62EK-201SBH136005R2062 3/221NFZ62EK-211SBH136005R2162 3/221NFZ62EK-221SBH136005R2262 3/221NFZ62EK-231SBH136005R2362 3/221NFZ62EK-301SBH136005R3062 3/220NFZ71E-201SBH136001R2071 3/214NFZ71E-211SBH136001R2171 3/214NFZ71E-221SBH136001R2271 3/214NFZ71E-231SBH136001R2371 3/214NFZ71E-301SBH136001R3071 3/213NFZ71EK-201SBH136005R2071 3/221NFZ71EK-211SBH136005R2171 3/221NFZ71EK-221SBH136005R2271 3/221NFZ71EK-231SBH136005R2371 3/221NFZ71EK-301SBH136005R3071 3/220NFZ80E-201SBH136001R2080 3/214NFZ80E-211SBH136001R2180 3/214NFZ80E-221SBH136001R2280 3/214NFZ80E-231SBH136001R2380 3/214NFZ80E-301SBH136001R3080 3/213NFZ80EK-201SBH136005R2080 3/221NFZ80EK-211SBH136005R2180 3/221NFZ80EK-221SBH136005R2280 3/221NFZ80EK-231SBH136005R2380 3/221NFZ80EK-301SBH136005R3080 3/220NS22E-201SBH101001R2022 5/30NS22E-261SBH101001R2622 5/30NS22ES-201SBH101004R2022 5/73NS22ES-261SBH101004R2622 5/73NS31E-201SBH101001R2031 5/30NS31E-261SBH101001R2631 5/30NS31ES-201SBH101004R2031 5/73NS31ES-261SBH101004R2631 5/73NS40E-201SBH101001R2040 5/30NS40E-261SBH101001R2640 5/30NS40ES-201SBH101004R2040 5/73NS40ES-261SBH101004R2640 5/73NS44E-201SBH101001R2044 5/30NS44E-261SBH101001R2644 5/30NS44ES-201SBH101004R2044 5/73NS44ES-261SBH101004R2644 5/73NS53E-201SBH101001R2053 5/30NS53E-261SBH101001R2653 5/30NS53ES-201SBH101004R2053 5/73NS53ES-261SBH101004R2653 5/73NS62E-201SBH101001R2062 5/30NS62E-261SBH101001R2662 5/30NS62ES-201SBH101004R2062 5/73NS62ES-261SBH101004R2662 5/73NS71E-201SBH101001R2071 5/30NS71E-261SBH101001R2671 5/30NS71ES-201SBH101004R2071 5/73NS71ES-261SBH101004R2671 5/73NS80E-201SBH101001R2080 5/30NS80E-261SBH101001R2680 5/30NS80ES-201SBH101004R2080 5/73NS80ES-261SBH101004R2680 5/73NSL22E-811SBH103001R8122 5/31NSL22ES-811SBH103004R8122 5/74NSL31E-811SBH103001R8131 5/31NSL31ES-811SBH103004R8131 5/74NSL40E-811SBH103001R8140 5/31NSL40ES-811SBH103004R8140 5/74NSL44E-811SBH103001R8144 5/31NSL44ES-811SBH103004R8144 5/74NSL53E-811SBH103001R8153 5/31NSL53ES-811SBH103004R8153 5/74NSL62E-811SBH103001R8162 5/31NSL62ES-811SBH103004R8162 5/74NSL71E-811SBH103001R8171 5/31NSL71ES-811SBH103004R8171 5/74NSL80E-811SBH103001R8180 5/31NSL80ES-811SBH103004R8180 5/74OESA460H/OESA400 1SFN085709R1000 3/265OXS6X1051SCA108043R1001 2/45OXS6X1301SCA101655R1001 2/45OXS6X1801SCA101659R1001 2/45OXS6X851SCA101647R1001 2/45PB1-1-321SAM201914R1001 2/41PBDTM-FBP.01SAJ924012R0006 11/15PDP32.01SAJ242000R0001 11/11PDR31.01SAJ243000R0001 11/11PN460-111SFN095705R1000 3/266PN460-211SFN095701R1000 3/266PN460-411SFN095703R1000 3/266PN750-111SFN096105R1000 3/266PN750-211SFN096101R1000 3/266PN750-411SFN096103R1000 3/266PNQ22-FBP.01SAJ261000R0100 11/13PR146-11SFN094200R1000 3/267PR185-21SFN095100R1001 3/267PR210-11SFN094900R1000 3/267PR300-11SFN095300R1000 3/267PR300-21SFN095300R1001 3/267PR400-21SFN095700R1002 3/267PR460-11SFN095700R1000 3/267PR460-21SFN095700R1001 3/267PR580-21SFN096100R1002 3/267PR750-11SFN096100R1000 3/267PR750-21SFN096100R1001 3/267PS1-2-0-651SAM201906R1102 2/41PS1-2-1-651SAM201906R1112 2/41PS1-2-2-651SAM201906R1122 2/41PS1-3-0-1001SAM201916R1103 2/41PS1-3-0-651SAM201906R1103 2/41PS1-3-1-1001SAM201916R1113 2/41PS1-3-1-651SAM201906R1113 2/41PS1-3-2-1001SAM201916R1123 2/41PS1-3-2-651SAM201906R1123 2/41PS1-4-0-1001SAM201916R1104 2/41PS1-4-0-651SAM201906R1104 2/41PS1-4-1-1001SAM201916R1114 2/41PS1-4-1-651SAM201906R1114 2/41PS1-4-2-651SAM201906R1124 2/41PS1-5-0-1001SAM201916R1105 2/41PS1-5-0-651SAM201906R1105 2/41PS1-5-1-1001SAM201916R1115 2/41PS1-5-1-651SAM201906R1115 2/41PS1-5-2-651SAM201906R1125 2/41PS2-2-0-1251SAM401920R1002 2/42PS2-2-2-1251SAM401920R1022 2/42PS2-3-0-1251SAM401920R1003 2/42PS2-3-2-1251SAM401920R1023 2/42PS2-4-0-1251SAM401920R1004 2/42PS2-4-2-1251SAM401920R1024 2/42RA41SBN060100R1000 3/252RA4-T 1SBN060100T1000 3/252RA5-11SBN060300R1000 3/2881SBN060300T1000 3/288CM-MSE1SVR550800R9300 7/101SVR550801R9300 7/101SVR550805R9300 7/10RC5-1/1331SBN050100R1001 5/13RC5-1/2501SBN050100R1002 5/13RC5-1/4401SBN050100R1003 5/13RC5-1/501SBN050100R1000 5/13RC5-2/1331SBN050200R1001 3/286RC5-2/2501SBN050200R1002 3/286RC5-2/4401SBN050200R1003 3/286RC5-2/501SBN050200R1000 3/286RC-EH800/110SK829007-C3/152RC-EH800/600SK829007-D3/152RT5/1501SBN050020R1003 3/286RT5/2641SBN050020R1004 3/286RT5/321SBN050020R1000 3/286RT5/651SBN050020R1001 3/286RT5/901SBN050020R1002 3/286RU19/1201SFN170801R1001 3/268RU19/2401SFN170801R1002 3/268RV5/1331SBN050010R1001 3/286RV5/2501SBN050010R1002 3/286RV5/4401SBN050010R1003 3/286RV5/501SBN050010R1000 3/286RV-BC6/250GHV2501903R0002 4/49RV-BC6/60GHV2501902R0002 4/49S1-M1-251SAM201907R1101 2/41S1-M2-251SAM201907R1102 2/41S1-M3-251SAM201907R1103 2/41S1-M3-351SAM201913R1103 2/41S1-PB1-251SAM201914R1002 2/41S801S-SCL100-SR2CCS801901R06398/2S801S-SCL32-SR2CCS801901R05398/2S801S-SCL63-SR2CCS801901R05998/2S802S-SCL100-SR2CCS802901R06398/2S802S-SCL32-SR2CCS802901R05398/2S802S-SCL63-SR2CCS802901R05998/2S803S-SCL100-SR2CCS803901R06398/2S803S-SCL32-SR2CCS803901R05398/2S803S-SCL63-SR2CCS803901R05998/2S803W-SCL100-SR 2CCS803917R0639 8/2S803W-SCL32-SR2CCS803917R05398/2S803W-SCL63-SR2CCS803917R05998/214
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/26SA1 GJF1101903R0001 2/41SA2 GJF1101903R0002 2/41SA3 GJF1101903R0003 2/41SK1-02 1SAM201903R1003 2/35SK1-02K 1SAM201903R1203 2/37SK1-11 1SAM201903R1001 2/35SK1-11K 1SAM201903R1201 2/37SK1-20 1SAM201903R1002 2/35SK1-20K 1SAM201903R1202 2/37SMK3.0 1SAJ929600R0001 11/12SMK3-X1.10 1SAJ929620R0001 11/12SMK3-X2.10 1SAJ929610R0001 11/12SPRC 1 1SNA360010R1500 3/256T16-0.13 1SAZ711201R1005 6/4T16-0.17 1SAZ711201R1008 6/4T16-0.23 1SAZ711201R1009 6/4T16-0.31 1SAZ711201R1013 6/4T16-0.41 1SAZ711201R1014 6/4T16-0.55 1SAZ711201R1017 6/4T16-0.74 1SAZ711201R1021 6/4T16-1.0 1SAZ711201R1023 6/4T16-1.3 1SAZ711201R1025 6/4T16-1.7 1SAZ711201R1028 6/4T16-10 1SAZ711201R1043 6/4T16-13 1SAZ711201R1045 6/4T16-16 1SAZ711201R1047 6/4T16-2.3 1SAZ711201R1031 6/4T16-3.1 1SAZ711201R1033 6/4T16-4.2 1SAZ711201R1035 6/4T16-5.7 1SAZ711201R1038 6/4T16-7.6 1SAZ711201R1040 6/4T4S 250 PR222MP In200 1SDA054527R1 12/21T4S 320 PR221-I In320 1SDA054126R1 12/23T5S 400 PR221-I In400 1SDA054335R1 12/23T5S 400 PR222MP In320 1SDA054553R1 12/21T5S 400 PR222MP In400 1SDA054554R1 12/21T5S 630 PR221-I In630 1SDA054405R1 12/23TA200DU-110 1SAZ421201R1002 6/25TA200DU-110-V1000 1SAZ421301R1002 6/25TA200DU-135 1SAZ421201R1003 6/25TA200DU-135-V1000 1SAZ421301R1003 6/25TA200DU-150 1SAZ421201R1004 6/25TA200DU-150-V1000 1SAZ421301R1004 6/25TA200DU-175 1SAZ411201R1005 12/36 1SAZ421201R1005 6/25TA200DU-175-V1000 1SAZ421301R1005 6/25TA200DU-200 1SAZ411201R1006 12/36 1SAZ421201R1006 6/25TA200DU-200-V1000 1SAZ421301R1006 6/25TA200DU-90 1SAZ421201R1001 6/25TA200DU-90-V1000 1SAZ421301R1001 6/25TEF3-OFF 1SBN021014R1000 5/13TEF3-ON 1SBN021012R1000 5/13TEF4-OFF 1SBN020114R1000 3/245TEF4-ON 1SBN020112R1000 3/245TEF4S-OFF 1SBN020115R1000 3/245TEF4S-ON 1SBN020113R1000 3/245TEF5-OFF 1SBN020314R1000 3/278TEF5-ON 1SBN020312R1000 3/278TF140DU-110 1SAZ431201R1002 6/21TF140DU-110-V1000 1SAZ431301R1002 6/21TF140DU-135 1SAZ431201R1003 6/21TF140DU-135-V1000 1SAZ431301R1003 6/21TF140DU-142 1SAZ431201R1004 6/21TF140DU-142-V1000 1SAZ431301R1004 6/21TF140DU-90 1SAZ431201R1001 6/21TF140DU-90-V1000 1SAZ431301R1001 6/21TF42-0.13 1SAZ721201R1005 6/8TF42-0.17 1SAZ721201R1008 6/8TF42-0.23 1SAZ721201R1009 6/8TF42-0.31 1SAZ721201R1013 6/8TF42-0.41 1SAZ721201R1014 6/8TF42-0.55 1SAZ721201R1017 6/8TF42-0.74 1SAZ721201R1021 6/8TF42-1.0 1SAZ721201R1023 6/8TF42-1.3 1SAZ721201R1025 6/8TF42-1.7 1SAZ721201R1028 6/8TF42-10 1SAZ711201R1043 12/36 1SAZ721201R1043 6/8TF42-13 1SAZ711201R1045 12/36 1SAZ721201R1045 6/8TF42-16 1SAZ711201R1047 12/36 1SAZ721201R1047 6/8TF42-2.3 1SAZ721201R1031 6/8TF42-20 1SAZ721201R1049 6/8TF42-24 1SAZ711201R1051 12/36 1SAZ721201R1051 6/8TF42-29 1SAZ721201R1052 6/8TF42-3.1 1SAZ721201R1033 6/8TF42-35 1SAZ711201R1053 12/36 1SAZ721201R1053 6/8TF42-38 1SAZ711201R1055 12/36 1SAZ721201R1055 6/8TF42-4.2 1SAZ721201R1035 6/8TF42-5.7 1SAZ721201R1038 6/8TF42-7.6 1SAZ721201R1040 6/8TF65-28 1SAZ811201R1001 6/13TF65-33 1SAZ811201R1002 6/13TF65-40 1SAZ811201R1003 6/13TF65-47 1SAZ811201R1004 6/13TF65-53 1SAZ811201R1005 6/13TF65-60 1SAZ811201R1006 6/13TF65-67 1SAZ811201R1007 6/13TF96-51 1SAZ911201R1001 6/17TF96-60 1SAZ911201R1002 6/17TF96-68 1SAZ911201R1003 6/17TF96-78 1SAZ911201R1004 6/17TF96-87 1SAZ911201R1005 6/17TF96-96 1SAZ911201R1006 6/17UA110-30-00 1SFL451022R8000 3/202 1SFL451022R8100 3/202 1SFL451022R8300 3/202 1SFL451022R8400 3/202 1SFL451022R8500 3/202 1SFL451022R8600 3/202 1SFL451022R8800 3/202UA110-30-00RA 1SFL451024R8000 3/196 1SFL451024R8100 3/196 1SFL451024R8400 3/196 1SFL451024R8500 3/196 1SFL451024R8600 3/196 1SFL451024R8800 3/196UA1-110 1SAM201904R1004 2/36UA1-20 1SAM201904R1010 2/36UA1-208 1SAM201904R1008 2/36UA1-230 1SAM201904R1005 2/36UA1-24 1SAM201904R1001 2/36UA1-400 1SAM201904R1006 2/36UA1-415 1SAM201904R1007 2/36UA1-48 1SAM201904R1002 2/36UA1-575 1SAM201904R1009 2/36UA1-60 1SAM201904R1003 2/36UA16-30-10 1SBL181022R8010 3/200 1SBL181022R8110 3/200 1SBL181022R8310 3/200 1SBL181022R8410 3/200 1SBL181022R8510 3/200 1SBL181022R8610 3/200 1SBL181022R8810 3/200UA16-30-10RA 1SBL181024R8010 3/194 1SBL181024R8110 3/194 1SBL181024R8410 3/194 1SBL181024R8510 3/194 1SBL181024R8610 3/194 1SBL181024R8810 3/194UA26-30-10 1SBL241022R8010 3/200 1SBL241022R8110 3/200 1SBL241022R8310 3/200 1SBL241022R8410 3/200 1SBL241022R8510 3/200 1SBL241022R8610 3/200 1SBL241022R8810 3/200UA26-30-10RA 1SBL241024R8010 3/194 1SBL241024R8110 3/194 1SBL241024R8410 3/194 1SBL241024R8510 3/194 1SBL241024R8610 3/194 1SBL241024R8810 3/194UA30-30-10 1SBL281022R8010 3/200 1SBL281022R8110 3/200 1SBL281022R8310 3/200 1SBL281022R8410 3/200 1SBL281022R8510 3/200 1SBL281022R8610 3/200 1SBL281022R8810 3/200UA30-30-10RA 1SBL281024R8010 3/194 1SBL281024R8110 3/194 1SBL281024R8410 3/194 1SBL281024R8510 3/194 1SBL281024R8610 3/194 1SBL281024R8810 3/194UA50-30-00 1SBL351022R8000 3/201 1SBL351022R8100 3/201 1SBL351022R8300 3/201 1SBL351022R8400 3/201 1SBL351022R8500 3/201 1SBL351022R8600 3/201 1SBL351022R8800 3/201UA50-30-00RA 1SBL351024R8000 3/195 1SBL351024R8100 3/195 1SBL351024R8400 3/195 1SBL351024R8500 3/195 1SBL351024R8600 3/195 1SBL351024R8800 3/195UA63-30-00 1SBL371022R8000 3/201 1SBL371022R8100 3/201 1SBL371022R8300 3/201 1SBL371022R8400 3/201 1SBL371022R8500 3/201 1SBL371022R8600 3/201 1SBL371022R8800 3/201UA63-30-00RA 1SBL371024R8000 3/195 1SBL371024R8100 3/195 1SBL371024R8400 3/195 1SBL371024R8500 3/195 1SBL371024R8600 3/195 1SBL371024R8800 3/19514
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage14/27ABB MOTOR PROTECTION AND CONTROLUA75-30-001SBL411022R8000 3/2011SBL411022R8100 3/2011SBL411022R8300 3/2011SBL411022R8400 3/2011SBL411022R8500 3/2011SBL411022R8600 3/2011SBL411022R8800 3/201UA75-30-00RA1SBL411024R8000 3/1951SBL411024R8100 3/1951SBL411024R8400 3/1951SBL411024R8500 3/1951SBL411024R8600 3/1951SBL411024R8800 3/195UA95-30-001SFL431022R8000 3/2021SFL431022R8100 3/2021SFL431022R8300 3/2021SFL431022R8400 3/2021SFL431022R8500 3/2021SFL431022R8600 3/2021SFL431022R8800 3/202UA95-30-00RA1SFL431024R8000 3/1961SFL431024R8100 3/1961SFL431024R8400 3/1961SFL431024R8500 3/1961SFL431024R8600 3/1961SFL431024R8800 3/196UMC100.3 DC 1SAJ530000R0100 11/8UMC100.3 DC EX 1SAJ530000R0200 11/8UMC100.3 DC EX Coated 1SAJ530000R0210 11/8UMC100.3 UC 1SAJ530000R1100 11/8UMC100.3 UC EX 1SAJ530000R1200 11/8UMC100.3 UC EX Coated 1SAJ530000R1210 11/8UMC100-PAN1SAJ590000R0103 11/9UMC100-PAN CAP 1SAJ510005R0001 11/9UMCIO-CAB.0301SAJ691000R0001 11/10UMCPAN-CAB.070 1SAJ510003R0002 11/9UMCPAN-CAB.150 1SAJ510004R0002 11/9UMCPAN-CAB.300 1SAJ510002R0002 11/9UMCTB.11SAJ929160R0002 11/10UMCTB-FBP.01SAJ929160R0001 11/10UTF21-FBP.01SAJ929400R0002 11/15UTP22-FBP.01SAJ924013R0001 11/15VB6-30-01-01GJL1211901R0011 4/10VB6-30-01-02GJL1211901R0012 4/10VB6-30-01-03GJL1211901R0013 4/10VB6-30-01-80GJL1211901R8010 4/10VB6-30-01-84GJL1211901R8014 4/10VB6-30-01-85GJL1211901R8015 4/10VB6-30-01-P-01GJL1211909R00114/22VB6-30-01-P-02GJL1211909R00124/22VB6-30-01-P-03GJL1211909R00134/22VB6-30-01-P-80GJL1211909R80104/22VB6-30-01-P-84GJL1211909R80144/22VB6-30-01-P-85GJL1211909R80154/22VB6-30-10-01GJL1211901R01014/10VB6-30-10-02GJL1211901R0102 4/10VB6-30-10-03GJL1211901R0103 4/10VB6-30-10-80GJL1211901R8100 4/10VB6-30-10-84GJL1211901R8104 4/10VB6-30-10-85GJL1211901R8105 4/10VB6-30-10-P-01GJL1211909R01014/22VB6-30-10-P-02GJL1211909R01024/22VB6-30-10-P-03GJL1211909R01034/22VB6-30-10-P-80GJL1211909R81004/22VB6-30-10-P-84GJL1211909R81044/22VB6-30-10-P-85GJL1211909R81054/22VB6A-30-01-01GJL1211911R00114/12VB6A-30-01-02GJL1211911R00124/12VB6A-30-01-03GJL1211911R00134/12VB6A-30-01-80GJL1211911R80104/12VB6A-30-01-84GJL1211911R80144/12VB6A-30-01-85GJL1211911R80154/12VB6A-30-01-P-01GJL1211919R00114/24VB6A-30-01-P-02GJL1211919R00124/24VB6A-30-01-P-03GJL1211919R00134/24VB6A-30-01-P-80GJL1211919R80104/24VB6A-30-01-P-84GJL1211919R80144/24VB6A-30-01-P-85GJL1211919R80154/24VB6A-30-10-01GJL1211911R01014/12VB6A-30-10-02GJL1211911R01024/12VB6A-30-10-03GJL1211911R01034/12VB6A-30-10-80GJL1211911R81004/12VB6A-30-10-84GJL1211911R81044/12VB6A-30-10-85GJL1211911R81054/12VB6A-30-10-P-01GJL1211919R01014/24VB6A-30-10-P-02GJL1211919R01024/24VB6A-30-10-P-03GJL1211919R01034/24VB6A-30-10-P-80GJL1211919R81004/24VB6A-30-10-P-84GJL1211919R81044/24VB6A-30-10-P-85GJL1211919R81054/24VB7-30-01-01GJL1311901R0011 4/10VB7-30-01-02GJL1311901R0012 4/10VB7-30-01-03GJL1311901R0013 4/10VB7-30-01-80GJL1311901R8010 4/10VB7-30-01-84GJL1311901R8014 4/10VB7-30-01-85GJL1311901R8015 4/10VB7-30-01-F-01GJL1311903R00114/32VB7-30-01-F-02GJL1311903R00124/32VB7-30-01-F-03GJL1311903R00134/32VB7-30-01-F-80GJL1311903R80104/32VB7-30-01-F-84GJL1311903R80144/32VB7-30-01-F-85GJL1311903R80154/32VB7-30-01-P-01GJL1311909R00114/22VB7-30-01-P-02GJL1311909R00124/22VB7-30-01-P-03GJL1311909R00134/22VB7-30-01-P-80GJL1311909R80104/22VB7-30-01-P-84GJL1311909R80144/22VB7-30-01-P-85GJL1311909R80154/22VB7-30-10-01GJL1311901R0101 4/10VB7-30-10-02GJL1311901R0102 4/10VB7-30-10-03GJL1311901R0103 4/10VB7-30-10-80GJL1311901R8100 4/10VB7-30-10-84GJL1311901R8104 4/10VB7-30-10-85GJL1311901R8105 4/10VB7-30-10-F-01GJL1311903R01014/32VB7-30-10-F-02GJL1311903R01024/32VB7-30-10-F-03GJL1311903R01034/32VB7-30-10-F-80GJL1311903R81004/32VB7-30-10-F-84GJL1311903R81044/32VB7-30-10-F-85GJL1311903R81054/32VB7-30-10-P-01GJL1311909R01014/22VB7-30-10-P-02GJL1311909R01024/22VB7-30-10-P-03GJL1311909R01034/22VB7-30-10-P-80GJL1311909R81004/22VB7-30-10-P-84GJL1311909R81044/22VB7-30-10-P-85GJL1311909R81054/22VB7A-30-01-01GJL1311911R00114/12VB7A-30-01-02GJL1311911R00124/12VB7A-30-01-03GJL1311911R00134/12VB7A-30-01-80GJL1311911R80104/12VB7A-30-01-84GJL1311911R80144/12VB7A-30-01-85GJL1311911R80154/12VB7A-30-01-F-01GJL1311913R00114/34VB7A-30-01-F-02GJL1311913R00124/34VB7A-30-01-F-03GJL1311913R00134/34VB7A-30-01-F-80GJL1311913R80104/34VB7A-30-01-F-84GJL1311913R80144/34VB7A-30-01-F-85GJL1311913R80154/34VB7A-30-01-P-01GJL1311919R00114/24VB7A-30-01-P-02GJL1311919R00124/24VB7A-30-01-P-03GJL1311919R00134/24VB7A-30-01-P-80GJL1311919R80104/24VB7A-30-01-P-84GJL1311919R80144/24VB7A-30-01-P-85GJL1311919R80154/24VB7A-30-10-01GJL1311911R01014/12VB7A-30-10-02GJL1311911R01024/12VB7A-30-10-03GJL1311911R01034/12VB7A-30-10-80GJL1311911R81004/12VB7A-30-10-84GJL1311911R81044/12VB7A-30-10-85GJL1311911R81054/12VB7A-30-10-F-01GJL1311913R01014/34VB7A-30-10-F-02GJL1311913R01024/34VB7A-30-10-F-03GJL1311913R01034/34VB7A-30-10-F-80GJL1311913R81004/34VB7A-30-10-F-84GJL1311913R81044/34VB7A-30-10-F-85GJL1311913R81054/34VB7A-30-10-P-01GJL1311919R01014/24VB7A-30-10-P-02GJL1311919R01024/24VB7A-30-10-P-03GJL1311919R01034/24VB7A-30-10-P-80GJL1311919R81004/24VB7A-30-10-P-84GJL1311919R81044/24VB7A-30-10-P-85GJL1311919R81054/24VBC6-30-01-01GJL1213901R00114/11VBC6-30-01-03GJL1213901R00134/11VBC6-30-01-04GJL1213901R00144/11VBC6-30-01-05GJL1213901R00154/11VBC6-30-01-07GJL1213901R00174/11VBC6-30-01-16GJL1213901R10164/11VBC6-30-01-P-01GJL1213909R00114/23VBC6-30-01-P-03GJL1213909R00134/23VBC6-30-01-P-04GJL1213909R00144/23VBC6-30-01-P-05GJL1213909R00154/23VBC6-30-01-P-07GJL1213909R00174/23VBC6-30-06-P-06GJL1213909R00164/23VBC6-30-10-01GJL1213901R01014/11VBC6-30-10-03GJL1213901R01034/11VBC6-30-10-04GJL1213901R01044/11VBC6-30-10-05GJL1213901R01054/11VBC6-30-10-07GJL1213901R01074/11VBC6-30-10-16GJL1213901R11064/11VBC6-30-10-P-01GJL1213909R01014/23VBC6-30-10-P-03GJL1213909R01034/23VBC6-30-10-P-04GJL1213909R01044/23VBC6-30-10-P-05GJL1213909R01054/23VBC6-30-10-P-06GJL1213909R01064/23VBC6-30-10-P-07GJL1213909R01074/23VBC6A-30-01-01GJL1213911R00114/13VBC6A-30-01-03GJL1213911R00134/13VBC6A-30-01-04GJL1213911R00144/13VBC6A-30-01-05GJL1213911R00154/13VBC6A-30-01-07GJL1213911R00174/13VBC6A-30-01-16GJL1213911R10164/13VBC6A-30-10-01GJL1213911R01014/13VBC6A-30-10-03GJL1213911R01034/13VBC6A-30-10-04GJL1213911R01044/13VBC6A-30-10-05GJL1213911R01054/13VBC6A-30-10-07GJL1213911R01074/13VBC6A-30-10-16GJL1213911R11064/13VBC7-30-01-01GJL1313901R00114/11VBC7-30-01-03GJL1313901R00134/11VBC7-30-01-04GJL1313901R00144/1114
—IndexType classificationTypeOrder codePageTypeOrder codePageTypeOrder codePage ABB MOTOR PROTECTION AND CONTROL 14/28VBC7-30-01-05 GJL1313901R0015 4/11VBC7-30-01-07 GJL1313901R0017 4/11VBC7-30-01-16 GJL1313901R1016 4/11VBC7-30-01-F-01 GJL1313903R0011 4/33VBC7-30-01-F-03 GJL1313903R0013 4/33VBC7-30-01-F-04 GJL1313903R0014 4/33VBC7-30-01-F-05 GJL1313903R0015 4/33VBC7-30-01-F-07 GJL1313903R0017 4/33VBC7-30-01-F-16 GJL1313903R1016 4/33VBC7-30-01-P-01 GJL1313909R0011 4/23VBC7-30-01-P-03 GJL1313909R0013 4/23VBC7-30-01-P-04 GJL1313909R0014 4/23VBC7-30-01-P-05 GJL1313909R0015 4/23VBC7-30-01-P-07 GJL1313909R0017 4/23VBC7-30-01-P-16 GJL1313909R1016 4/23VBC7-30-10-01 GJL1313901R0101 4/11VBC7-30-10-03 GJL1313901R0103 4/11VBC7-30-10-04 GJL1313901R0104 4/11VBC7-30-10-05 GJL1313901R0105 4/11VBC7-30-10-07 GJL1313901R0107 4/11VBC7-30-10-16 GJL1313901R1106 4/11VBC7-30-10-F-01 GJL1313903R0101 4/33VBC7-30-10-F-03 GJL1313903R0103 4/33VBC7-30-10-F-04 GJL1313903R0104 4/33VBC7-30-10-F-05 GJL1313903R0105 4/33VBC7-30-10-F-07 GJL1313903R0107 4/33VBC7-30-10-F-16 GJL1313903R1106 4/33VBC7-30-10-P-01 GJL1313909R0101 4/23VBC7-30-10-P-03 GJL1313909R0103 4/23VBC7-30-10-P-04 GJL1313909R0104 4/23VBC7-30-10-P-05 GJL1313909R0105 4/23VBC7-30-10-P-07 GJL1313909R0107 4/23VBC7-30-10-P-16 GJL1313909R1106 4/23VBC7A-30-01-01 GJL1313911R0011 4/13VBC7A-30-01-03 GJL1313911R0013 4/13VBC7A-30-01-04 GJL1313911R0014 4/13VBC7A-30-01-05 GJL1313911R0015 4/13VBC7A-30-01-07 GJL1313911R0017 4/13VBC7A-30-01-16 GJL1313911R0016 4/13VBC7A-30-01-F-01 GJL1313913R0011 4/35VBC7A-30-01-F-03 GJL1313913R0013 4/35VBC7A-30-01-F-04 GJL1313913R0014 4/35VBC7A-30-01-F-05 GJL1313913R0015 4/35VBC7A-30-01-F-07 GJL1313913R0017 4/35VBC7A-30-01-F-16 GJL1313913R1016 4/35VBC7A-30-01-P-01 GJL1313919R0011 4/25VBC7A-30-01-P-03 GJL1313919R0013 4/25VBC7A-30-01-P-04 GJL1313919R0014 4/25VBC7A-30-01-P-05 GJL1313919R0015 4/25VBC7A-30-01-P-07 GJL1313919R0017 4/25VBC7A-30-01-P-16 GJL1313919R1016 4/25VBC7A-30-10-01 GJL1313911R0101 4/13VBC7A-30-10-03 GJL1313911R0103 4/13VBC7A-30-10-04 GJL1313911R0104 4/13VBC7A-30-10-05 GJL1313911R0105 4/13VBC7A-30-10-07 GJL1313911R0107 4/13VBC7A-30-10-16 GJL1313911R1106 4/13VBC7A-30-10-F-01 GJL1313913R0101 4/35VBC7A-30-10-F-03 GJL1313913R0103 4/35VBC7A-30-10-F-04 GJL1313913R0104 4/35VBC7A-30-10-F-05 GJL1313913R0105 4/35VBC7A-30-10-F-07 GJL1313913R0107 4/35VBC7A-30-10-F-16 GJL1313913R1106 4/35VBC7A-30-10-P-01 GJL1313919R0101 4/25VBC7A-30-10-P-03 GJL1313919R0103 4/25VBC7A-30-10-P-04 GJL1313919R0104 4/25VBC7A-30-10-P-05 GJL1313919R0105 4/25VBC7A-30-10-P-07 GJL1313919R0107 4/25VBC7A-30-10-P-16 GJL1313919R1106 4/25VE5-2 1SBN030210R1000 3/282VEM4 1SBN030111R1000 3/248VEM4K 1SBN030113R1000 3/264VH800 SK829070-F 3/152VI150-FBP.0 1SAJ650000R0100 11/10VI155-FBP.0 1SAJ655000R0100 11/10VM140/190 1SFN034403R1000 3/248VM1650H 1SFN036503R1001 3/248VM19 1SFN030300R1000 3/248VM205/265 1SFN035203R1000 3/248VM3 1SBN031005T1000 5/13VM370/400 1SFN035403R1000 3/248VM4 1SBN030105T1000 3/248VM750H 1SFN035700R1000 3/248VM750V 1SFN035701R1000 3/248VM96-4 1SBN033405T1000 3/248WA4-10 1SBN040100R1010 3/254WA4-11 1SBN040100R1011 3/254WA4-12 1SBN040100R1012 3/254WA4-13 1SBN040100R1013 3/254WA4-14 1SBN040100R1014 3/254WA4-96-11 1SBN040200R1011 3/254WA4-96-12 1SBN040200R1012 3/254WA4-96-13 1SBN040200R1013 3/254WA4-96-14 1SBN040200R1014 3/254WB75-A FPTN372726R1001 3/290 FPTN372726R1002 3/290 FPTN372726R1003 3/290 FPTN372726R1004 3/290 FPTN372726R1005 3/290 FPTN372726R1006 3/290 FPTN372726R1007 3/290 FPTN372726R1008 3/290WRB-1000 1SAZ701903R1013 6/44WRB-400 1SAZ701903R1011 6/44WRB-600 1SAZ701903R1012 6/44WRBG 1SAZ701903R1030 6/44WRH-F 1SAZ701903R1001 6/44XT2S 160 1SDA068164R1 12/21XT2S 160 MA 160 1SDA076530R1 12/23XT4S 250 Ekip I In250 1SDA068480R1 12/23ZA110 1SFN154310R8006 3/295 1SFN154310R8106 3/295 1SFN154310R8406 3/295 1SFN154310R8506 3/295 1SFN154310R8606 3/295 1SFN154310R8806 3/295ZA16 1SBN151410R8006 3/295 1SBN151410R8106 3/295 1SBN151410R8406 3/295 1SBN151410R8506 3/295 1SBN151410R8606 3/295 1SBN151410R8806 3/295ZA40 1SBN152410R8006 3/295 1SBN152410R8106 3/295 1SBN152410R8406 3/295 1SBN152410R8506 3/295 1SBN152410R8606 3/295 1SBN152410R8806 3/295ZA75 1SBN153510R8006 3/295 1SBN153510R8106 3/295 1SBN153510R8406 3/295 1SBN153510R8506 3/295 1SBN153510R8606 3/295 1SBN153510R8806 3/295ZAF1650 1SFN156570R7026 3/269ZAF2650 1SFN156670R7026 3/269ZAF460 1SFN155770R6806 3/269 1SFN155770R6906 3/269 1SFN155770R7006 3/269 1SFN155770R7106 3/269ZAF750 1SFN156170R6806 3/269 1SFN156170R6906 3/269 1SFN156170R7006 3/269 1SFN156170R7106 3/269ZL1250 1SFN166403R1000 3/269ZL1350 1SFN166503R1000 3/269ZL1350-1 1SFN166503R1001 3/269ZL1650 1SFN166703R1000 3/269ZL1650-1 1SFN166703R1001 3/269ZL2050 1SFN167003R1000 3/269ZL2050-1 1SFN167003R1001 3/269ZL2650 1SFN166603R1000 3/269ZL400 1SFN165703R1000 3/269ZL460 1SFN165903R1000 3/269ZL580 1SFN166103R1000 3/269ZL750 1SFN166303R1000 3/269ZLU110 1SFN164502R1000 3/295ZLU50 1SBN163502R1000 3/295ZLU63 1SBN163702R1000 3/295ZLU75 1SBN164102R1000 3/295ZLU95 1SFN164302R1000 3/295ZP1650 1SFN166521R1070 3/269ZP2650 1SFN166621R1070 3/269ZW1650 1SFN166510R1001 3/269ZW2650 1SFN166610R1000 3/269ZW460 1SFN165710R1000 3/269ZW750 1SFN166110R1000 3/26914
15/1ABB MOTOR PROTECTION AND CONTROLhttp://new.abb.com/low-voltage/products/motor-protection—Marketing material15
1SBC100058S0201_NCABB MOTOR PROTECTION AND CONTROL 15/2Select Optimized Coordination tables SOCCadenas portal: Download 2D or 3D files according to your needs (STEP, IGES...)Main catalog : 1SBC100214C0201 Motor protection and controlMAIN CATALOG 2018 Motor protection and controlManual motor starters, contactors and overload relays Motor protection and controlMAIN CATALOG 2018 Motor protection and controlManual motor starters, contactors and overload relays—Main online toolsFor direct product details information, use product type or order code, ex:www.abb.com/productdetails/AF09-30-10-13 or www.abb.com/productdetails/1SBL137001R1310Videos, prints, technical presentations and more15
http://www.abb.com/lowvoltagehttp://new.abb.com/low-voltage/products/motor-protectionWe reserve the right to make technical changes or modify the contents of this document without prior notice. ABB does not accept any responsibility whatsoever for po-tential errors or possible lack of information in this docu-ment.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduc-tion, disclosure to third parties or utilization of its con-tents – in whole or in parts – is forbidden without prior written consent of ABB.Copyright© 2019 ABB - All rights reserved1SBC100214C0201 - Printed in France ( 03.2019 PDF)—ABB France Electrification Products DivisionLow Voltage Products and Systems3, rue Jean PerrinF-69687 Chassieu cedex / France— ABB STOTZ-KONTAKT GmbHElectrification Products DivisionLow Voltage Products and SystemsEppelheimer Straße 82D-69123 Heidelberg / Germany— ABB ABElectrification Products DivisionLow Voltage Products and SystemsProtection & ConnectionSE-721 61 Västerås / SwedenYou can find the address of your local sales organization on the ABB home page