Product Overview

29CARLO GAVAZZI Automation Components. Specications are subject to change without notice. Illustrations are for example only.29• Motor thermistor relays for PTC connection• Remote or local, automatic or manual alarm reset• PTC open or short circuit. Information LED for status and troubleshooting• 1 or 2 relays outputThermistor relaysDTA01/02, DTA71/72• Motor thermistor relays for PTC connection• Remote or local, automatic or manual alarm reset• PTC open or short circuit. Information LED for status and troubleshooting• 2 x 8 A SPST relay output• Relay outputs for contactor opening and signalling• 24 V to 240 V AC/DC power supply voltage• Fixed [DEA01] or Adjustable I∆n threshold [DEB71]• Warning output @ 60% I∆n• Trip Output @ 80% I∆n• Adjustable time delay [DEB71]• 2 SPDT relay outputs• Sealable antitampering lid [DEB71]Thermistor relayDTA04Earth LeakageDEA71/DEB71Pump alternating relays DLA71/DLA73Power relaysDWA01/DWB• For 2 or 3 pumps• Pump rotation and multiple pumps activation• Overflow relay output [DLA73]• 2 x 5A SPST relay output [DLA71 2P] 3 x 5A SPST relay output [DLA71 3P, DLA73]• Cosφ or Active power monitoring • Direct reading up to 5 A, 10 A or through “MI” current transfomers for higher currents• Adjustable Cosφ or selectable independent upper and lower values • Adjustable delay ON• 1 x 8 A SPDT relay outputMonitoring relaysThe possibilities for monitoring relays are countless: verification of machinery operation, detection of broken heater elements, lighting monitoring in critical areas (airport runways, buildings aircraft warning lights, tunnels), monitoring of ventilation fans and in building automation systems. Protection can be provided against people, fire, earth current leakage, or protecting from incorrect mains or cables connections. Also cabling and mounting is eased using different types of housing, double cage terminals, or pass-through connections for current measurement. Setup is always easy and accurate with the front dials and DIP switches.• TRMS AC or DC voltage monitoring• Over + over or over + under or under + under• Separately adjustable delays, adjustable hysteresis• Programmable latch / inhibit function• 2 x 8 A SPDT relay output• Zero current transformer for DEA71 and DEB71• Suitable for 1-phase and 3-phase mains• Max. Input voltage 750 VAC• Reduction ratio 1:1000• Opening from 35 mm to 210 mm• Over and underfrequency monitoring• Rated frequency 50 Hz or 60 Hz• Adjustable delay on alarm ON or on recovery• Programmable latch / inhibit function• 1 x 8 A SPDT outputCurrent/Voltage relays DIC01/DUC01Core balance transformers CTGFrequency relays DFB01/DFC01• AC/DC TRMS over or undervoltage monitoring• Range up to 500 VAC or DC• Adjustable delay and hysterersys• Programmable latching / inhibit• 1 x 8 A SPDT relay output• Over and undervoltage monitoring• Measure own supply 24 V, 115 V, 230 V AC [DUB02], 24-240 V AC/DC [DUB03]• Adjustable delay on alarm ON or on recovery• Programmable latch / inhibit function• 1 x 8 A SPDT output• DC battery undervoltage monitoring• 12 V, 24 V and 48 V battery systems• Adjustable voltage and hysterersys settings• 1 x 5 A SPDT relay output• Voltage window relay• Nominal voltage from 208 to 240 V AC• Monitoring own supply• Incorrect connection proof (208-480 V AC power supply)• 5A SPDT relay outputVoltage relaysDUA01/DUB01Voltage relaysDUB02/DUB03Voltage relaysDUA52Voltage relaysDUA55

Previous page: Product Overview [28 / 32]

Next page: Product Overview [30 / 32]