Prefabricerad kanalskena för belysning och

44www.se.comRun component characteristicsRating of trunking (A)2540General characteristicsCompliance with standardsIEC/EN 61439-6IEC/EN 61439-6Degree of protectionIP5555Mechanical impactsIK0606ColorRAL 9003 whiteRAL 9003 whitePolarityL1NPE or L2L1L3NPEL1NPE or L2L1L3NPENumber of live conductors2 or 42 or 4Rated current at an ambient temperature of 35°CIncA2540Rated insulation voltageUiV690690Rated operational voltageUeV230...400230...400Rated impulse voltageUimpkV44Rated frequencyfHz50/6050/60Conductor characteristicsPhase conductorsMean resistance at an ambient temperature of 20°CR20mΩ/m6.802.83Mean resistance at Inc and 35°CR1mΩ/m8.303.46Mean reactance at Inc, 35°C and 50 HzX1mΩ/m0.020.02Mean impedance at Inc, 35°C and 50 HzZ1mΩ/m8.333.46Protective conductor (PE)Mean resistance at an ambient temperature of 20°CmΩ/m1.571.57Fault loop characteristicsSymmetrical components methodPh/Nat 20°CMean resistanceR0 ph/NmΩ/m27.2119.40Mean reactanceX0 ph/NmΩ/m0.850.38Mean impedanceZ0 ph/NmΩ/m27.2219.41Ph/PEat 20°CMean resistanceR0 ph/PEmΩ/m19.4013.83Mean reactanceX0 ph/PEmΩ/m0.380.73Mean impedanceZ0 ph/PEmΩ/m19.4113.85Impedance methodAt 20°CMean resistancePh/PhRb0 ph/phmΩ/m13.615.68Ph/NRb0 ph/NmΩ/m13.615.68Ph/PERb0 ph/PEmΩ/m11.017.66For Incat 35°CMean resistancePh/PhRb1 ph/phmΩ/m16.606.91Ph/NRb1 ph/NmΩ/m16.606.91Ph/PERb1 ph/PEmΩ/m12.508.70For Incat 35°C and50 HzMean reactancePh/PhXb ph/phmΩ/m0.040.90Ph/NXb ph/NmΩ/m0.040.90Ph/PEXb ph/PEmΩ/m0.0350.035Other characteristicsShort-circuit withstand capacityRated peak withstand currentIpkkA4.409.60Maximum thermal limit I2tA2s195 x 103900 x 103Rated short-time withstand current (t = 1 s)IcwkA0.440.94Voltage dropComposite voltage drop (hot state) expressed in V/100 m/A (50 Hz) with the load uniformly distributed over the run. If the load is concentrated at one end of the run, the voltage drop is twice the value indicated in the table.For a power factor of1V/100 m/A0.720.300.9V/100 m/A0.670.280.8V/100 m/A0.610.250.7V/100 m/A0.540.22This table is given for three-phases network. The single phase voltage drop is obtained bydividing the three-phase voltage drop indicated above by 0.866. For lower neutral / neutral voltage phase, we divide the voltage drop above by 1.732.Radiated magnetic fieldRadiated magnetic field strength 1 metre from the trunkingBμT< 2 x 10-3< 2 x 10-3Derating in case of harmonicsOperational current as a function of 3rd harmonic contentTHD y 15 %254015 % < THD y 33 %2032THD > 33 %1628Permissible current as a function of ambient temperatureAmbient temperature°C< 353540455055Cœfficient K1%n/a10.960.930.890.85Design guideCharacteristicsCanalis KBA

Previous page: Prefabricerad kanalskena för belysning och [43 / 68]

Next page: Prefabricerad kanalskena för belysning och [45 / 68]