3www.philips.com/LEDtube‹ Back to contentswww.philips.com/LEDtube3Q2 2023MASTER LEDtube HF T5 HO - 600 mmBallast CompatibilityKEYMAS LEDtube HF 600mm HO 10.5W 8xx T5Model number / (Short) EOC code:9290035962 / 8720169163072009290035963 / 8720169163096009290035964 / 872016916311900Ballast type12ncLamps on ballastAC (50Hz) on HF Ballast CompatibleBAG-HUECOBCS39.1FX-11/220-240100775811BCD39.1F-01/220-240/1-10V100972461 * *BCS39.2FX-11/220-240100775822BCD39.2F-01/220-240/1-10V100972962 * MLS54.2F-01/220-2401664122 * *MLD39.1FR-11/220-240/DALI100978111MLS39.1-2FR-11/220-240100920261 * *MLS39.1-2FR-11/220-240100920262MLD39.2FR-11/220-240/DALI100921172* * / Dim (3)MLD14/24.3FR-04/220-240/DALI101051503* * / Dim (3)MLS14/24.3-4FR-11/220-240100953453 * *MLS14/24.3-4FR-11/220-240100953454 * *MLS80.1F-01/220-2401663121OthersDirect mainsWorks with High Frequency ballast (HF)HFBallast is compatibleThis document is for information purposes and must be treated as recommendation. Signify attempted to provide best results, results are generated in lab controlled environment and may differ from actual application conditions*Ballast is compatible, light output may differ >10% compared to speci�cations**DimBallast is compatible and conditional released for dimmingBallast is not compatibleMASTER LEDtube HF InstantFit T5 HO General notes: Refer to the product ref er ence number in the header of the columns to use this product-ballast compatibility list. Please note that Philips LEDtubes InstantFit T5 are only tested with HF ballast on AC operation. The performance of Philips LEDtubes InstantFit T5 on HF ballasts with DC operation is not tested and is theref ore not guaranteed. Philips LEDtubes InstantFit T5 range is designed to work on HF ballasts only. This document is for information purposes only and must be treated as recommendation. Signify will not accept claims for any damage caused by not implementing the recommendations in this document. Signify does not accept any responsibility, warranty or liability when using Philips LEDtubes with ballasts not mentioned in this list, or when using successor models of the tested ballasts. Although Signify aims to provide the most accurate information and test results from controlled experiments the results may vary in differ ent applications. This document focuses on the behaviour of above mentioned Philips LEDtube. Please also check and follow the instructions of HF ballast manufacturers for installation instructions.Always check the latest update of the compatibility list on www.philips.com/ledtubeDimming a LEDtube: Please note that the dimming curve of the LEDtube might differ from the curve of a �uorescent lamp. (1) Do not use in closed luminaires(2) Do not use in combination with a motion sensor (3) Do not Dim below 10% / Dali step 170 (4) Do not Dim below 20% / Dali step 185 Q3-Q4 2024