DCM1500SSolar clamp meterDESCRIPTIONMeasuring up to 2000 V DC and 1500 V AC (using the PVHV Leads), as well as 1500A AC or DC, the DCM1500S is ideal for use in the installation, maintenance, monitoring and testing of photovoltaic systems as well standard AC or DC electrical equipment.The meter is supplied with both standard 4mm leads as well as the new PVHV1 (4mm) and PVHV2 (MC4PV) HV lead sets. It has a large clear backlit display and an automatic torch in the jaw to assist use in poorly lit areas.Using the free Megger Link App, the measurement value can be remotely monitored on a smart device using the built-in Bluetooth®. This will give a live trend graph and offer the ability to sample and log the values for later analysis. The smart data-hold expands the standard hold function by giving the operator an audible warning if the “held” reading increases by 50 counts or above. Min/Max hold provides the ability to measure the maximum and minimum values over a period of time, with each value selectable in turn.Other features include a High Frequency Rejection Filter, inrush current measurement, internal data logging, a non-contact volt seek mode and manual DC Amp zeroingIn addition to voltage and current measurement the DCM1500S has the ability to measure Resistance, Diode, Capacitance, temperature and Frequency.The DCM1500S is safety rated to IEC 61010-1 and IEC/EN61010-2-033 CAT IV 600V, and CAT III 1000VAPPLICATIONThe DCM1500S is designed to be used on electrical systems and equipment, including Solar/Photovoltaic installations where, there is a need to measure current, volts, resistance and frequency. It is therefore intended for use while installing, maintaining, fault-finding or monitoring those systems.The tactile barrier below the jaws of the instrument ensures a safe working distance for the operator’s hand when measuring current on live uninsulated conductors, although additional personal protection must still be used.The Smart Hold allows increases in measurements to be monitored with an audible tone.The Max/Min and In-rush modes enable maximum load currents from equipment to be identified such as start-up currents to motors and heaters. 2000 V DC TRMS 1500 V AC 1500 A AC/DC Smart Hold Auto ranging MIN/MAX Hold Inrush Current Megger Link app compatible CAT IV 600V / CAT III 1000V Data logger PV test leads with MC4PV plugswww.megger.com 1
DCM1500SSolar clamp meterwww.megger.com 2The DC current measurement can also be used in applications including battery monitoring, automotive, charging and load circuits, electric vehicle servicing, lift maintenance, UPS commissioning, servicing and maintenance, electro-plating plants and welding equipment servicing as well as domestic power generation from solar panels and wind-turbines. ADDITIONAL FEATURES 6,000 counts digital display Large white LED backlit display True RMS reading on ACA/ACV AC/DC μA Range Resistance, Diode, Capacitance & Frequency measurement °C/°F temperature function Inrush current DCA ZERO Torch light on trigger push Data Logging up to 1000 records Manual save mode Auto Power offDC mVRangeOL ReadingResolutionAccuracy600.0 mV660.0 mV0.1 mV± (0.7% + 5D)DC VoltageRangeOL ReadingResolutionAccuracy600.0 V660.0 V0.1 V± (0.7% + 2D)1000 V1100 V1 VAC VoltageRangeOL ReadingResolutionAccuracy600.0 V660.0 V0.1 V± (1.0% + 5D)1000 V1100 V1 VPV DC Voltage (using PVHV1 or PVHV2 lead set)RangeOL ReadingResolutionAccuracy600.0 V660.0 V0.1 V± (2.0% + 5D)2000 V2200 V1 VPV AC Voltage (using PVHV1 or PVHV2 lead set)RangeOL ReadingResolutionAccuracy600.0 V660.0 V0.1 V± (2.0% + 5D)1500 V1600 V1 VAC/DC μARangeOL ReadingResolutionAccuracy400.0 μA440.0 μA0.1 μA± (1.0% + 3D)4000 μA4400 μA1 μA
www.megger.com 3DCM1500SSolar clamp meterAC/DC CurrentRangeOL ReadingResolutionAccuracy60.00 A66.00 A0.01 A± (2.0% + 5D)600.0 A660.0 A0.1 A1500 A1550 A1 AFrequencyRangeOL ReadingResolutionAccuracy100.00 Hz100.00 Hz0.01 Hz± (0.3% + 3D)1000.0 Hz1000.0 Hz0.1 Hz10.000 kHz10.000 kHz0.001 kHzResistanceRangeOL ReadingResolutionAccuracy600.0 Ω660.0 Ω0.1 Ω± (0.9% + 5D)6.000 kΩ6.600 kΩ0.001 kΩ± (0.9% + 2D)60.00 kΩ66.00 kΩ0.01 kΩ600.0 kΩ660.0 kΩ0.1 kΩContinuityBuilt-in buzzer sounds when measured resistance is less than 20Ω and the sound is off when measured resistance is more than 200 Ω, between 20 Ω to 200 Ω the buzzer may be either on or off.DiodeRangeOL ReadingResolutionAccuracy1.500 V1.550 V0.001 V± (0.9% + 2D)CapacitanceRangeOL ReadingResolutionAccuracy100.0 μF110.0 μF0.1 μF± (1.9% + 2D)1000 μF1100 μF1 μFVoltSeekVoltage Range of High Sensitivity : 80 V ~ 1000 V (At the top edge of the jaw)Voltage Range of Low Sensitivity : 160 V ~ 1000 V (At the top edge of the jaw)TemperatureRangeOL ReadingResolutionAccuracy-40.0 °C – 400.0 °C440.0 °C0.1 °C± (1% + 20D)-40.0 °F – 752.0 °F824.0 °F0.1 °F± (1% + 36D)
SALES OFFICE Megger LimitedArchcliffe Road DoverCT17 9EN EnglandT +44 (0) 1304 502101E UKsales@megger.comDCM1500S_DS_en_V01bwww.megger.comISO 9001The word ‘Megger’ is a registered trademarkDCM1500SSolar clamp meterORDERING INFORMATIONItem (qty) Part No: DCM1500S 1013-357Included Accessories DCM 4mm Lead Set (Inc. Probes and Crocodile Clips) 1013-358TP-90 Thermocouple Probe 1013-364PVHV1 Lead (4mm Plugs) 1013-362PVHV2 Lead (MC4PV Plugs) 1013-363Hard Carry Case