www.megger.com17SpecificationsAVO® 215Resistance RangeResolutionAccuracy400 Ω0.1 kΩ+/- (1.5 % reading + 5 digits)4 kΩ0.001 kΩ40 kΩ0.01 kΩ400 kΩ0.1 kΩ4 MΩ0.001 MΩ40 MΩ0.01 MΩ+/- (2.5 % reading + 20 digits)Capacitance RangeResolutionAccuracy40 nF0.01 nF+/- (4.5 % reading + 10 digits)400 nF0.1 nF4 μF0,001 μF+/- (3.0 % reading + 5 digits)40 μF0.01 μF400 μF0.1 μF4000 μF1 μF+/- (5 % reading + 5 digits)Frequency RangeResolutionAccuracy10 Hz – 10 kHz0.01 Hz+/- (1.2 % reading)Sensitivity: 15 V rmsDuty Cycle RangeResolutionAccuracy0.1 to 99.9 %0.1 %+/- (1.2 % reading + 2 digits)Pulse width: 100 μs – 100 ms, Frequency: 5 Hz to 150 kHzNOTE : Accuracy is stated at 18 °C to 28 °C (65 °F to 83 °F) and less than 75 % RH. NOTE : Accuracy specifications consist of two elements. (% reading) = accuracy of the measurement circuit. (+ digits ) = accuracy of analog to digital converter.Drop test: 6.5 feet (2 metres)Diode test: Test current of 1.5 mA maximum, open circuit voltage 3 V DC typicalContinuity check: Audible signal will sound if the resistance is less than 50 Ω (approx.), test current <0.35 mA