ARCON 3G

7ProductDescriptionVersionTypeArticle no.Electronic evaluation unit Master LITE is suitable as a simple, active arc fault monitoring system based on light detection only for detecting internal faults in a switchgear assembly, control of the assigned circuit breaker via shunt release actuation;- Display of system status via internal Display and LEDs- Up to 31 light detection modules can be connected - 3x high-speed (< 1 ms) trip relay outputs (16 A / 250 V AC/DC)- 1x trip alarm and watchdog output relay for remote status indication- Easy mounting on DIN-rail profile (TS35)- No parameter setting required- Supply voltage 24 V DCARC-LITE-3G193889Electronic evaluation unit Master MAIN for use as an active arc fault protection system based on light and current detection for detecting internal faults in a switchgear assembly to fulfill extensive "personnel and assembly protection";- Display of system status via internal Display / LEDs and HMI- Up to 31 light detection modules can be connected - 3x high-speed (< 1 ms) trip relay outputs (16 A / 250 V AC/DC)- 1x trip alarm and watchdog output relay for remote status indication- 1x connection of tripping module to operate external quenching device- Total arc mitigation time ≤ 2 ms- Easy mounting on DIN-rail profile (TS35)- Parameter and system configuration via software (APPT)- Additional measurement of Voltage, Power, Frequency for displaying the values- Supply voltage 24 V DCARC-MAIN-3G193890Electronic detection module for up to 3 fiber optic line sensors or up to 6 electronic point sensors and 1 mobile light sensor, connection via INTERLINK (max. 100 m) to the respective master unit;- Display of triggered channel via LEDs when light detected by sensor- Easy mounting on DIN-rail profile (TS35)- Supply via internal bus connectionARC-DMOD-3SLARC-DMOD-6NTFS193892193895Electronic tripping module for generating the ignition voltage / current for the pressure elements in the arc quenching device (AQD), both ignition circuits are permanently monitored for wire faults;- Display of RUN and TRIP mode via LEDs (aligned with AQD)- Easy mounting on DIN-rail profile (TS35)- Pre-assembled connection cable (3 m) to AQD included- Supply voltage 24 V DCARC-TMOD-1QD193893The arc fault is quenched by a 3-phase short-circuit device directly at the main busbar close to the main incomer. Total arc mitigation time of ≤ 2 ms means interval of time between the ignition of the internal arc-fault and the complete extinction of the same.- Display of RUN and TRIP mode via LEDs (aligned with tripping module)- Rated impulse-withstand voltage Uimp: 8 kV- Rated operational voltage: 690 V AC- Rated short-time withstand current Icw: 85 kA / 1 s, 105 kA / 0.5 s, 150 kA / 0.2 sUNIVERSALinstallationARC-AT-T/3G300936Electronic display and control unit for parameterization and status indication for connection to the electronic evaluation unit Master MAIN;- Input via 5.8" resistive touchscreen display and 3 function keys- Panel mounted device, protection degree IP55 (front)- Supply voltage 24 V DC- 1 display can serve up to 8 master modulesARC-MAIN-HMI193891Special light sensor for detecting the light emitted by an arc fault. Blue protective hose for increased filter effect and reduced sensitivity to interfering light. Temperature stability up to max. 125°C for the active sensing area.- Outstanding tripping response- Best performance criteria for line sensor installations against nuisance tripping- Continuous self-supervision of the sensor loop via monitoring signal- Total length of the sensor minus 5 m means the active sensing area10 m11 m12 m13 m15 m17 m20 m25 mARC-SL10/BLARC-SL11/BLARC-SL12/BLARC-SL13/BLARC-SL15/BLARC-SL17/BLARC-SL20/BLARC-SL25/BL179679179680179681179682179683179684179685179686Intelligent point sensor for detecting the light emitted by an arc fault. Due to a precise algorithm the sensor can distinguish between different light sources. As an example, it won't trip when there is some blow-out gas caused by a circuit breaker during standard switching operation. Moreover it's non-sensitive against other interfering lights like sun light, artificial lighting, photo flash, torch light, etc.- Nuisance Tripping Free Sensor with SPE plug for permanent use (3 m / 6 m)- Nuisance Tripping Free Sensor with RJ9 plug for temporary use (5 m) (extended protection during service/maintenance of energized assemblies)3 m6 m5 mARC-NTFS-3MARC-NTFS-6MARC-NTFS-MLS300939300940300941Specified connection cables for INTERLINK, IGNITION PORT, iCOM and MASTERLINK communication based on RJ45 connector system and Ethernet cabling Cat.6A (class EA).- Max. transmission distance via ... INTERLINK communication line: 100 m ... IGNITION PORT communication line: 10 m ... iCOM communication line: 100 m ... MASTERLINK communication line: 100 m0.5 m1 m2 m3 m5 m7.5 m10 m15 m20 mARC-CC00ARC-CC01ARC-CC02ARC-CC03ARC-CC05ARC-CC07ARC-CC10ARC-CC15ARC-CC20286390286391286392170488286393170489286394286395268396Range OverviewTripping ModuleDisplay ModuleFiber Optic Line SensorPoint Sensor and Mobile Light SensorCommunication CablesArc Quenching DeviceMaster LITEMaster MAINDetection Modules

Previous page: ARCON 3G [6 / 8]

Next page: ARCON 3G [8 / 8]