CatalogProtective DevicesArc Fault Detection Device AFDD+,Eaton.com
1.11EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole• Arc Fault Detection Device acc. to IEC/EN-62606• Detects and quenches arc faults in final circuits• Fully combined with residual current circuit breaker (RCCB) and miniature circuit breaker (MCB)• 2-pole: Both clearances between open contacts are protected• Variable installation of N either to the left or right• Rated currents from 6 to 40 A• Contact position indicator red – green• Tripped indication: MCB, RCCB or AFDD• LED indication for arc faults• Permanent self-monitoring• Overvoltage and overheat monitoring• Guide for secure terminal connection• 3-position DIN rail clip, permits removal from existing busbar system• Comprehensive range of accessories suitable for subsequent installation• 10 and 30 mA rated residual currents• Tripping characteristics B, C• Rated breaking capacity up to 10 kA• The -OL types are specifically designed to fullfill the tripping characteristic requirements of I2 ≤ Iz in the Norwegian electrotechnical standard NEK 400-8-823.Descriptionsg06416
1.22EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-poleType F, 10 kA, 2-poleSurge current-proof 3 kA, sensitive to residual pulsating DC, type Fsg0641610OL/0.03AFDD-10/2/B/003-F-OL MB-3001841/4013OL/0.03AFDD-13/2/B/003-F-OLMB-3001851/4015OL/0.03AFDD-15/2/B/003-F-OLMB-3001861/4020OL/0.03AFDD-20/2/B/003-F-OLMB-3001871/4010/0.03AFDD-10/2/B/003-F1872431/4013/0.03AFDD-13/2/B/003-F1872531/4016/0.03AFDD-16/2/B/003-F1872631/4020/0.03AFDD-20/2/B/003-F1872721/4025/0.03AFDD-25/2/B/003-F1872781/40In/IDn (A)Type DesignationArticle No.Units per package10OL/0.03AFDD-10/2/C/003-F-OLMB-3001791/4013OL/0.03AFDD-13/2/C/003-F-OLMB-3001801/4015OL/0.03AFDD-15/2/C/003-F-OLMB-3001811/4020OL/0.03AFDD-20/2/C/003-F-OLMB-3001821/406/0.03AFDD-6/2/C/003-FMB-3001781/4010/0.03AFDD-10/2/C/003-F1872491/4013/0.03AFDD-13/2/C/003-F1872591/4016/0.03AFDD-16/2/C/003-F1872691/4020/0.03AFDD-20/2/C/003-F1872751/4025/0.03AFDD-25/2/C/003-F1872811/40Characteristic CType F, 6 kA, 2-poleSurge current-proof 3 kA, sensitive to residual pulsating DC, type F32/0.03AFDD-32/2/B/003-F1872841/4040/0.03AFDD-40/2/B/003-F1872901/40Characteristic B32/0.03AFDD-32/2/C/003-F1872871/4040/0.03AFDD-40/2/C/003-F1872931/40Characteristic Csg06416Characteristic B
1.33EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-poleType G/A, 10 kA, 2-poleSurge current-proof 3 kA, sensitive to residual pulsating DC, type G/Asg0641610/0.01AFDD-10/2/B/001-G/AMB-3001941/4013/0.01AFDD-13/2/B/001-G/AMB-3001951/4016/0.01AFDD-16/2/B/001-G/AMB-3001961/4010/0.03AFDD-10/2/B/003-G/AMB-3001621/4013/0.03AFDD-13/2/B/003-G/AMB-3001651/4016/0.03AFDD-16/2/B/003-G/AMB-3001681/4020/0.03AFDD-20/2/B/003-G/AMB-3001701/4025/0.03AFDD-25/2/B/003-G/AMB-3001731/40In/IDn (A)Type DesignationArticle No.Units per packageCharacteristic B6/0.01AFDD-6/2/C/001-G/AMB-3001881/4010/0.01AFDD-10/2/C/001-G/AMB-3001891/4013/0.01AFDD-13/2/C/001-G/AMB-3001911/4016/0.01AFDD-16/2/C/001-G/AMB-3001921/406/0.03AFDD-6/2/C/003-G/AMB-3001381/4010/0.03AFDD-10/2/C/003-G/AMB-3001471/4013/0.03AFDD-13/2/C/003-G/AMB-3001491/4016/0.03AFDD-16/2/C/003-G/AMB-3001521/4020/0.03AFDD-20/2/C/003-G/AMB-3001531/4025/0.03AFDD-25/2/C/003-G/AMB-3001551/40Characteristic CType G/A, 6 kA, 2-poleSurge current-proof 3 kA, sensitive to residual pulsating DC, type G/A32/0.03AFDD-32/2/B/003-G/AMB-3001741/4040/0.03AFDD-40/2/B/003-G/AMB-3002221/40Characteristic B32/0.03AFDD-32/2/C/003-G/AMB-3001581/4040/0.03AFDD-40/2/C/003-G/AMB-3001591/40Characteristic Csg06416
1.44EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-poleType A, 10 kA, 2-poleShort-time delayed, sensitive to residual pulsating DC, type Asg0641610/0.01AFDD-10/2/B/001-Li/A 187166 1/4013/0.01AFDD-13/2/B/001-Li/A 187178 1/4016/0.01AFDD-16/2/B/001-Li/A 187202 1/4010/0.03AFDD-10/2/B/003-Li/A 187169 1/4013/0.03AFDD-13/2/B/003-Li/A 187181 1/4015OL/0.03AFDD-15/2/B/003-Li/A-OL 187193 1/4016/0.03AFDD-16/2/B/003-Li/A 187205 1/4020OL/0.03AFDD-20/2/B/003-Li/A-OL 187214 1/4020/0.03AFDD-20/2/B/003-Li/A 187220 1/4025/0.03AFDD-25/2/B/003-Li/A 187226 1/40In/IDn (A)Type DesignationArticle No.Units per packageCharacteristic B6/0.01AFDD-6/2/C/001-Li/AMB-3002071/4010/0.01AFDD-10/2/C/001-Li/A 187172 1/4013/0.01AFDD-13/2/C/001-Li/A 187184 1/4016/0.01AFDD-16/2/C/001-Li/A 187208 1/406/0.03AFDD-6/2/C/003-Li/AMB-3002231/4010/0.03AFDD-10/2/C/003-Li/A 187175 1/4013/0.03AFDD-13/2/C/003-Li/A 187187 1/4015OL/0.03AFDD-15/2/C/003-Li/A-OL 187199 1/4016/0.03AFDD-16/2/C/003-Li/A 187211 1/4020OL/0.03AFDD-20/2/C/003-Li/A-OL 187217 1/4020/0.03AFDD-20/2/C/003-Li/A 187223 1/4025/0.03AFDD-25/2/C/003-Li/A 187229 1/40Characteristic CType A, 6 kA, 2-poleShort-time delayed, sensitive to residual pulsating DC, type A32/0.03AFDD-32/2/B/003-Li/A 187232 1/4040/0.03AFDD-40/2/B/003-Li/A 187238 1/40Characteristic B32/0.03AFDD-32/2/C/003-Li/A 187235 1/4040/0.03AFDD-40/2/C/003-Li/A 187241 1/40Characteristic Csg06416
1.55EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-poleType A, 10 kA, 2-poleNon-delayed, sensitive to residual pulsating DC, type Asg0641610/0.01AFDD-10/2/B/001-A 187165 1/4010OL/0.03AFDD-10/2/B/003-A-OLMB-3002171/4013OL/0.03AFDD-13/2/B/003-A-OLMB-3002211/4013/0.01AFDD-13/2/B/001-A 187177 1/4016/0.01AFDD-16/2/B/001-A 187201 1/4010/0.03AFDD-10/2/B/003-A 187168 1/4013/0.03AFDD-13/2/B/003-A 187180 1/4015OL/0.03AFDD-15/2/B/003-A-OL 187192 1/4016/0.03AFDD-16/2/B/003-A 187204 1/4020OL/0.03AFDD-20/2/B/003-A-OL 187213 1/4020/0.03AFDD-20/2/B/003-A 187219 1/4025/0.03AFDD-25/2/B/003-A 187225 1/40In/IDn (A)Type DesignationArticle No.Units per packageCharacteristic B6/0.01AFDD-6/2/C/001-AMB-3002061/4010/0.01AFDD-10/2/C/001-A 187171 1/4010OL/0.03AFDD-10/2/C/003-A-OLMB-3002151/4013OL/0.03AFDD-13/2/C/003-A-OLMB-3002161/4013/0.01AFDD-13/2/C/001-A 187183 1/4016/0.01AFDD-16/2/C/001-A 187207 1/406/0.03AFDD-6/2/C/003-AMB-3001991/4010/0.03AFDD-10/2/C/003-A 187174 1/4013/0.03AFDD-13/2/C/003-A 187186 1/4015OL/0.03AFDD-15/2/C/003-A-OL 187198 1/4016/0.03AFDD-16/2/C/003-A 187210 1/4020OL/0.03AFDD-20/2/C/003-A-OL 187216 1/4020/0.03AFDD-20/2/C/003-A 187222 1/4025/0.03AFDD-25/2/C/003-A 187228 1/40Characteristic CType A, 6 kA, 2-poleNon-delayed, sensitive to residual pulsating DC, type A32/0.03AFDD-32/2/B/003-A 187231 1/4040/0.03AFDD-40/2/B/003-A 187237 1/40Characteristic B32/0.03AFDD-32/2/C/003-A 187234 1/4040/0.03AFDD-40/2/C/003-A 187240 1/40Characteristic Csg06416
1.66EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-poleType AC, 10 kA, 2-poleNon-delayed, alternating-current-sensitive, type ACsg0641610/0.01AFDD-10/2/B/001 187164 1/4013/0.01AFDD-13/2/B/001 187176 1/4016/0.01AFDD-16/2/B/001 187200 1/4010/0.03AFDD-10/2/B/003 187167 1/4013/0.03AFDD-13/2/B/003 187179 1/4016/0.03AFDD-16/2/B/003 187203 1/4020/0.03AFDD-20/2/B/003 187218 1/4025/0.03AFDD-25/2/B/003 187224 1/40In/IDn (A)Type DesignationArticle No.Units per packageCharacteristic B6/0.01AFDD-6/2/C/001MB-3002051/4010/0.01AFDD-10/2/C/001 187170 1/4013/0.01AFDD-13/2/C/001 187182 1/4016/0.01AFDD-16/2/C/001 187206 1/406/0.03AFDD-6/2/C/003MB-3001971/4010/0.03AFDD-10/2/C/003 187173 1/4013/0.03AFDD-13/2/C/003 187185 1/4016/0.03AFDD-16/2/C/003 187209 1/4020/0.03AFDD-20/2/C/003 187221 1/4025/0.03AFDD-25/2/C/003 187227 1/40Characteristic CType AC, 6 kA, 2-poleNon-delayed, alternating-current-sensitive, type AC32/0.03AFDD-32/2/B/003 187230 1/4040/0.03AFDD-40/2/B/003 187236 1/40Characteristic B32/0.03AFDD-32/2/C/003 187233 1/4040/0.03AFDD-40/2/C/003 187239 1/40Characteristic Csg06416
1.77EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole - Technical DataSpecifications | Arc Fault Detection Device AFDD+, 2-poleDescription• Arc Fault Detection Device acc. to IEC/EN-62606• Line-voltage-independent RCBO (combined switch) acc. to IEC/EN 61009• 2-pole: Both clearances between open contacts are protected• Variable installation of N either to the left or the right• Tripped indication: MCB, RCCB or AFDD• LED indication for arc faults• Compatible with standard busbar• Twin-purpose terminal (lift/open-mouthed) above and below• Busbar positioning optionally above or below• Free terminal space despite installed busbar• Guide for secure terminal connection• Switching toggle (MCB component) in colour designating the rated current• Contact position indicator red - green• Comprehensive range of accessories can be mounted subsequently• The test key “T” must be pressed every 6 months. The system operator must be informed of this obligation and their responsibility in a way that can be proven (self-adhesive RCD-label enclosed). The test interval of 6 months is valid for residential and similar applications. Under all other conditions (e.g. damp or dusty environments), it’s recommended to test in shorter intervals (e.g. monthly).• Pressing the test key “T” serves the only purpose of function testing the residual current device (RCD). This test does not perform an earthing resist-ance measurement (RE), nor does it render the check of the earth conductor condition redundant, which means both tests must additionally be performed separately.• The cable length (one-way) from the AFDD+ to the socket outlet should not exceed 70 m. This guarantees that arc faults can be detected reliably.• Type -A: Protects against special forms of residual pulsating DC which have not been smoothed• Type -Li/A: As Type –A, but in addition it is short-time delayed. Highly reliable against unwanted tripping.• Type -F: Sensitive to pulsating DC residual current and detection of multi-frequency residual currents up to 1 kHz -Increased protection due to the detection of mixed frequencies -Higher load rating with DC residual currents up to 10 mA -Reduction of nuisance tripping thanks to time delayed tripping and increased current withstand capability of 3 kA Recommended for washing machines, dish washers, or motor applications with single-phase drives.• Type -G/A: Additionally protects against special forms of residual pulsating DC which have not been smoothed• Type -G: High reliability against unwanted tripping. Suitable for any circuit where personal injury or damage to property may occur in case of unwanted tripping. Additionally protects against special forms of residual pulsating DC which have not been smoothed.• OL types: Specifically designed to fulfill the tripping characteristic requirements of I2 ≤ Iz in the Norwegian electrotechnical standard NEK 400-8-823. 10:28 Error memory:The AFDD+ saves the last tripping reason/cause. If the device is in the open position (turned off), press and hold the test button “T” and simultaneously turn on the device. This causes the in-built LED to flash in a sequence that will reveal the tripping cause.Accessories:Auxiliary switch for subsequent installationZP-IHK286052Auxiliary switchZP-NHK248437ZP-WHK286053Shunt trip releaseZP-ASA/..248438, 248439BusbarsEVG-2PHAS/4AFDD; ZV-SS; ZV-L1/N; ZV-L2/L3; ZV-ADP; ZV-AEK
1.88EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole - Technical DataTechnical DataAFDD+ElectricalDesign according toRelevant effective certification marks as printed onto the deviceIEC/EN 62606IEC/EN 61009IEC/EN 62423Type G acc. to ÖVE E 8601Line voltage-independent trippinginstantaneous surge current proof 250 A (8/20 μs) surge current proof 3 kA (F, -F-OL, -G/A, -G/A-OL) (8/20 μs)Rated voltageUn240 V AC; 50 HzOperational voltage range180-264 VSelf-consumption< 0.8 WRated residual operating currentIDn10, 30 mARated residual non-operating currentIDno0.5 IDnSensitivityAC and pulsating DC, Type FSelectivity class3Rated breaking capacityAFDD 6-25 A10 kAAFDD 32-40 A6 kARated current6 - 40 ARated insulation voltageUi440 VRated impulse withstand voltageUimp4 kV (1.2/50 μs)Rated residual making and breaking capacityIDmEN 610093 kAIEC 610096-16 A: 3 kA20-40 A: 500 AArc fault tripping times after load current (acc. to IEC/EN 62606)Load current (A)Tripping time (s)2,5<15<0.510<0.2516<0.1532<0.1240<0.12CharacteristicB, C, B(-OL), C(-OL)Maximum back-up fuse (short-circuit)100 A gL (>10 kA)Enduranceelectrical components> 4,000 switching operationsmechanical components> 20,000 switching operationsMechanicalFrame size45 mmDevice height80 mmDevice width54 mm (3 MU)Mounting 3-position DIN rail clip, permits removal from existing busbar systemDegree of protection, switch IP20Degree of protection, built-inIP40Upper and lower terminals open-mouthed/lift terminalsTerminal protection finger and hand touch safe, EN 50274Terminal cross section (capacity)1 - 25 mm2Busbar thickness 0.8 - 2 mmOperating temperature -25° C to +40° CStorage and transport temperature-35° C to +60° CResistance to climatic conditionsaccording to IEC/EN 61009
1.99EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole - Technical DataConnection diagram2-pole1234TDIAFDDDimensions (mm)548045104460Tripping Characteristic AFDD+, Characteristics B and CDeclaration AFDD reason for trippingAfter switching on the AFDD is initially a test LED (LED sequence red-yellow-green -> continuous green).Any previous arc tripping reasons are shown only one time after switching on again.Green, no arcing as tripping reason1x yellow, serial arc2x yellow, serial arc of a dimmed load3x yellow, parallel arc4x yellow, over voltage (about 270V) AFDD tripped for self protection5x yellow, overtemperature in the device (about >115°C) AFDD tripped for self protection6x yellow, device error, please check device by an expertThe last AFDD error can be reshown by pressing the test key while the device is switched on.Tripping Characteristic -OL Type 15A, 20A
1.1010EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole - Technical DataShort-circuit Selectivity AFDD+ 10-20 A towards Neozed1) / Diazed2) / NH003)Short-circuit currents in kA, rated currents of fuses in AShort-circuit selectivity AFDD+ towards Neozed 1)Darker areas: no selectivity1) SIEMENS Type 5SE2; Size: D01, D02, D03; Operating class gG; Rated voltage: AC 400 V/DC 250 V2) SIEMENS Type 5SB2, 5SB4, 5SC2; Size: DII, DIII, DIV; Operating class gG; Rated voltage: AC 500 V/DC 500 V3) SIEMENS Type 3NA3 8, 3NA6 8, 3NA7 8; Size: 000, 00; Operating class gG; Rated voltage: AC 500 V/DC 250 VShort-circuit selectivity AFDD+ towards Diazed 2)Short-circuit selectivity AFDD+ towards NH00 3)Short-circuit Selectivity AFDD+ 25-40 A towards Neozed1) / Diazed2) / NH003)Short-circuit currents in kA, rated currents of fuses in AShort-circuit selectivity AFDD+ towards Neozed 1)Short-circuit selectivity AFDD+ towards Diazed 1)Darker areas: no selectivity1) SIEMENS Type 5SE2; Size: D01, D02, D03; Operating class gG; Rated voltage: AC 400 V/DC 250 V2) SIEMENS Type 5SB2, 5SB4, 5SC2; Size: DII, DIII, DIV; Operating class gG; Rated voltage: AC 500 V/DC 500 V3) SIEMENS Type 3NA3 8, 3NA6 8, 3NA7 8; Size: 000, 00; Operating class gG; Rated voltage: AC 500 V/DC 250 VShort-circuit selectivity AFDD+ towards NH00 3)AFDD+Neozed 1)In [A]162025323540506380100B10/B10-OL<0.50.50.922.33.78101010B13/B13-OL<0.50.50.81.71.936101010B16/B15-OL0.50.71.51.72.44.46.81010B20/B20-OL0.71.41.52.23.969.210C10/C10-OL<0.50.50.81.71.936.1101010C13/C13-OL<0.50.50.71.61.82.85.59.51010C16/B15-OL<0.50.71.31.52.246.21010C20/C20-OL0.61.31.42.13.75.68.510AFDD+Diazed 2)In [A]1620253235506380100B10/B10-OL<0.50.50.91.82.95.6101010B13/B13-OL<0.50.50.81.52.44.5101010B16/B15-OL0.50.81.323.481010B20/B20-OL0.71.31.93.17.11010C10/C10-OL<0.50.50.81.52.44.4101010C13/C13-OL<0.50.50.81.42.34.2101010C16/B15-OL<0.50.71.21.93.27.61010C20/C20-OL0.71.21.82.96.59.710AFDD+NH00 3)In [A]162025323540506380100125160B10/B10-OL<0.5<0.50.81.52.33.25.79.110101010B13/B13-OL<0.5<0.50.81.31.92.74.46.510101010B16/B15-OL<0.50.71.11.62.23.44.88101010B20/B20-OL0.611.423.14.37101010C10/C10-OL<0.5<0.50.71.31.92.74.56.910101010C13/C13-OL<0.5<0.50.71.21.82.54.16.110101010C16/B15-OL<0.50.611.523.14.47.5101010C20/C20-OL0.60.91.41.92.94.16.5101010AFDD+Neozed 1)In [A]162025323540506380100B251.21.31.83.14.766B321.21.72.73.85.56B401.31.72.22.74.2C251.11.31.82.83.95.66C321.21.72.63.65.16C401.31.93.33.25.8AFDD+Diazed 2)In [A]1620253235506380100B251.11.52.45.566B321.42.14.366B401.42.42.95.1C251.11.52.34.466C321.42.24.15.66C401.62.83.66AFDD+NH00 3)In [A]162025323540506380100125160B250.91.21.62.43.45.5666B321.11.42.12.94.3666B401.41.92.84.166C250.91.21.62.334.6666C321.11.52.12.84.3666C401.52.13.15.466
1.1111EATON CORPORATION CA019040ENProtective DevicesArc Fault Detection Device AFDD+, 2-pole - Technical DataLet-through Energy AFDD+Let-through Energy AFDD+, Characteristic B, 2-pole, 10-20 ALet-through Energy AFDD+, Characteristic C, 2-pole, 6-20 AB20 / B20-OLB10B13B16 / B15-OLProspective Short-circuit Current Icc [A]Let-through Energy I2t [A2 sec]C20/ C20-OLC10C13C16 / C15-OLLet-through Energy I2t [A2 sec]Prospective Short-circuit Current Icc [A]Let-through Energy AFDD+, Characteristic B, 2-pole, 25-40 ALet-through Energy AFDD+, Characteristic C, 2-pole, 25-40 AProspective Short-circuit Current Icc [A]Let-through Energy I2t [A2 sec]Let-through Energy I2t [A2 sec]Prospective Short-circuit Current Icc [A]
Eaton EMEA HeadquartersRoute de la Longeraie 71110 Morges, Switzerland© 2021 EatonAll Rights ReservedPrinted in Austria Publication No. CA019040ENArticle number 302723-MKFebruary 2021Grafics: SRA, Schrems9 010238177932Eaton Industries (Austria) GmbHScheydgasse 421210 ViennaAustriaFollow us on social media to get the latest product and support information.Eaton is a registered trademark.All other trademarks are property of their respective owners.To contact us please visit https://www.eaton.com/us/en-us/support/international-support-contacts.html For technical questions please contact your local Eaton team.Changes to the products, to the information contained in thisdocument, and to prices are reserved; as are errors and omissions.Only order confirmations and technical documentation by Eaton isbinding. Photos and pictures also do not warrant a specific layout orfunctionality. Their use in whatever form is subject to prior approvalby Eaton. The same applies to trademarks (especially Eaton, Moeller,and Cutler-Hammer). The Terms and Conditions of Eaton apply, asreferenced on Eaton Internet pages and Eaton order confirmations.Eaton’s electrical business is a global leader with deep regional application expertise in power distribution and circuit protection; power quality, backup power and energy storage; control and automation; life safety and security; structural solutions; and harsh and hazardous environment solutions. Through end-to-end services, channel and an integrated digital platform & insights Eaton is powering what matters across industries and around the world, helping customers solve their most critical electrical power management challenges.For more information, visit Eaton.com.